WALLACE & TIERNAN GAS CHLORINATION

S10K GAS FEED SYSTEM

PRODUCT OVERVIEW Easy to read icons provide positive indication of cylinder


The S10K gas feed system is a vacuum operated, status. The operator can tell at a glance whether
sonically regulated unit. Direct cylinder mounting puts the container is in the standby status (for automatic
the vacuum-regulating valve right at the source, reducing switchover) operating, empty or off.
gas pressure to a vacuum immediately. It provides for Positive shutoff
economic low capacity gas feed applications for municipal An OFF position on the face of the regulator allows for
and industrial water and wastewater treatment and positive shutoff. Containers can be changed without
disinfection, swimming pools and industrial process water. admitting air, dirt or moisture into the control unit and
Its ability to handle all water treatment gases as well as its without shutting off the injector.
flexible mounting configurations for cylinders, manifolds
or ton containers provides versatility for all installations.
KEY BENEFITS
Two basic arrangements are available in capacities of 4
and 10 kilograms per hour / 200 and 500 pounds per day Easy to read icons provide positive indication of
(PPD) of chlorine gas. With fewer internal parts, you can conatiner status
be confident that the S10K gas feed system will provide Positive shutoff allows conatiners to be changed
reliable, dependable service. without admitting air, dirt or moisture into control unit
Easy alignment of the control unit on the container by
FEATURES means of a captive yoke assembly
Complete gas consumption by means of a non-
Positive indication of operating status isolating switchover system
Flexible installation with detachable flowmeter
assemblies for remote wall mounting

standby* operating empty off


*auto switchover only
Unique secondary check Distance, supply to the control unit
The 10 kg/hr (500 PPD) regulator includes a unique For flexibility, it is not necessary to install the vacuum
secondary check designed to confine gas under pressure regulating valve close to the control unit. It can be up to
should the primary valve not seat completely due to several hundred feet from the gas control unit, depending
contamination. This minimises the possibility of venting gas on maximum feed rate, the diameter of the connecting pipe
to atmosphere. or tubing and system performance requirements.
Built-in automatic switchover (option) Injector operating water
Built-in switchover eliminates the need for external Injector operating water must be reasonably clean.
switching devices. The non-isolating feature allows Injectors are fixed-throat differential type. Maximum inlet
cylinders to be emptied thoroughly, for complete gas pressure is 20 bar/300 psi to a maximum of 38 C/100 F;
consumption. 10 bar/150 psi to a maximum of 54.4 C/130 F.
Captive universal yoke mounting Pressure at application point
A unique self aligning captive Maximum pressure with hose or polyethylene tubing is
yoke clamp makes it easy to line 5 bar/75 psi. High pressure hose or rigid pipe will allow
up and connect the gas feed application against back pressure to 10.7 bar/160 psi.
system to the gasketed outlet of a A solution pump after the injector will allow application
container valve. A similar captive against higher pressure.
yoke design is used for ammonia Swimming pools
cylinders. A ton container kit
includes a drip leg, to trap initial For non-residential swimming pool applications a unique
spurts of liquid, a heater for evaporation and a replaceable package is available.
filter can be provided. A universal yoke is available for Control methods
international cylinder variants.
Feed rate of any S10K gas feeder is controlled by either one
Handles all water treatment gases or both of these methods: interrupting the injector-water
The unit can handle all typical water treatment gases e.g. supply to shut off the gas feeders operating vacuum or
chlorine, sulphur dioxide, carbon dioxide and ammonia. changing V-Notch orifice area (by positioning the v-grooved
plug in its ring) while holding vacuum differential across the
Detachable flowmeters orifice constant.
Two sizes of flowmeters, 75 and 125 mm (3 and 5) are Manual control
available in 15 capacities to 10 kg/hr (500 PPD) chlorine
(comparable capacities for other gases). Manual control by changing orifice area (V-Notch plug
These flowmeters can be integral to the position) via an adjustment knob on gas feed system.
unit, or mounted remote, for installation Start-stop or program control
flexibility. Flowmeters can be ganged
This type of control is achieved with simple
together for multiple points of application.
implementation. Operating vacuum is started and stopped
When used with optional vacuum solenoid
by interrupting the injector water supply.
valves multiple rate control can be
achieved. Automatic control
The S10K gas feed system can be provided with automatic
TECHNICAL DATA feed rate control ranging from simple to complex control
The S10K gas feed system is simple in design, compact schemes. The control system can consist of a simple direct
and easy to handle. Injector installation only requires mA control V-Notch actuator or a more sophisticated
connecting to a water supply and running plastic tubing control including an actuator and a controller (choice
to a main or open channel. A knob adjustment on the of either a Multifunction Controller (MFC), a Signal
flowmeter changes gas feed rate, which is indicated on a Conditioning Unit (SFC-SC) or a Process Control Unit
high resolution 75 or 125 mm (3 or 5) scale. (SFC-PC).

Accuracy Direct 4-20 mA input control (see WT.040.050.000.


UA.PS)
Gas feed is 4% of the indicated flow.
Direct 4-20 mA input signal from an external control
Operating range
device
Manual 20:1 for any flowmeter. Compact integral design
Automatic 10:1. Internal dosage capability
CONNECTIONS
Pipe and plastic tubing sizes.

VACUUM REGULATING VALVES


Tubing to: 4 kg/hr / 200 PPD 10 kg/hr / 500 PPD
Control unit 3/8 x 1/2 1/2 x 5/8
Container Gas inlet is yoke connection to a cylinder or
valve header valve or, with optional adapter, to a
ton container valve

INJECTORS
Connection 4 kg/hr / 200 PPD 10 kg/hr / 500 PPD
Water inlet 3/4 male NPT or 1 female NPT
flexible pipe
Water 3/4 male NPT or 3/4 NPT with
outlet flexible pipe adaptors for 3/4
(optional), 1, or
1-1/2 pipe or hose

OVERALL DIMENSIONS
Gas feed system

75 mm / 3 Rotameter 200 x 178 x 278 mm

125 mm / 5 Rotameter 210 x 305 x 330 mm

Automatic panel 5 Rotameter 640 x 187 x 181 mm

Shipping weight
Gas metering unit 2.3 kg

Automatic panel 7.3 kg

GASES AND CAPACITIES


Chlorine/Sulfur dioxide Carbon dioxide Ammonia
3" 5" 3" 5" 3" 5"
24 g/h 60 g/h 20 g/h 48 g/h 12 g/h 30 g/h
60 g/h 200 g/h 48 g/h 160 g/h 30 g/h 100 g/h
200 g/h 400 g/h 160 g/h 320 g/h 100 g/h 200 g/h
400 g/h 600 g/h 320 g/h 480 g/h 200 g/h 300 g/h
600 g/h - 480 g/h - 300 g/h -
1000 g/h 1000 g/h 800 g/h 800 g/h 500 g/h 500 g/h
1.5 kg/h - 1.2 kg/h - 740 g/h -
2 kg/h 1.5 kg/h 1.6 kg/h 1.2 kg/h 1000 g/h 740 g h
3 kg/h 2 kg/h 2.4 kg/h 1.6 kg/h 1.5 kg/h 1000 g/h
4 kg/h 3 kg/h 3.2 kg/h 2.4 kg/h 2 kg/h 1.5 kg/h
- 4 kg/h - 3.2 kg/h - 2 kg/h
- 5 kg/h - 4 kg/h - 2.2 kg/h
- 6 kg/h - 4.8 kg/h - 3 kg/h
- 8 kg/h - 6.4 kg/h - 4 kg/h
- 10 kg/h - 8 kg/h - 5 kg/h
MFC (see WT.050.580.000.UA.PS) OPTIONS
Direct flow proportional control or control adjustments Related options include: cylinder valves and connections;
Single feedback or direct residual closed-loop control header valves with manifolding and connections; vent;
Compound loop control injector water and injector outlet lines and clamps; main
Set point trim control connections; solenoid valves; water line pressure gauge;
Outputs: standard outputs of the MFC consists of high vacuum pressure switch and alarm; leak detectors; on
four individual 0/4-20 mA outputs, RS-485 digital line analysers; cylinder scales; residual test kits; injector
communications vacuum gauges; spare parts and PM Kit replacement
SFC-SC (see WT.050.590.020.UA.PS) parts.

Operating modes: flow proportional, manual Chlorine Gas Warning


Inputs: 4-20 mA DC (from flow transmitter) All unattended chlorine gas containers and chlorination
Outputs: control out to actuator; also 4-20mA output equipment should be monitored for leaks. Sensitive
for retransmission of gas feed rate (actuator position) chlorine detectors, which respond quickly to chlorine in the
Control capability: dosage and flow scaling atmosphere, should be installed at each site. See product
sheet WT.050.130.000.UA.PS for further details.
SFC-PC (see WT.050.590.010.UA.PS)
Carbon Dioxide Warning
Operating modes: direct residual feed back, compound
loop, feed forward, flow proportional, manual Because of the high pressure in carbon dioxide containers,
Ranges: set points up to 50mg/L and center-zero the vacuum regulating valve cannot be mounted directly
capability for dechlorination on the container. A pressure reducing valve and pressure
Inputs: up to 3 analog (flow, residual, spare); 2 digital relief valve must be installed between the container and the
Outputs: control out to actuator; plus user-configurable vacuum regulating valve.
4-20mA; RS-485 serial communications Compliance
Control logic: proportional and integral with process
time Gas feeders, controller and actuator are designed to
Alarms: 4 user-configurable for 16 different conditions conform to all applicable NEC and NEMA specifications
and Chlorine Institute and Compressed Gas Association
recommendations. Consult an Evoqua repesentative to
ensure your compliance with AS/ZNS 2927.

885 Mountain Highway, Bayswater, VIC, 3153, Australia

1300 661 809 (Ph) / +61 3 8720 6597 (Int) 1300 661 708 (Fax) / +61 3 8720 6502 (Int) www.evoqua.com.au

PM Kit, S10K and Wallace & Tiernan are trademarks of Evoqua, its subsidiaries and affiliates, in some countries. NEMA is a trademark of the
National Electrical Manufactures Association. NEC is a trademark of the National Fire Protection Association.

All information presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as
to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Evoqua
assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products.

2014 Evoqua Water Technologies Pty Ltd Subject to change without notice WT-025200.000-UA-AU-PS-A4-0714