You are on page 1of 7

08/30/2017 at 04:50:32 Page 1 Of 7 364515255.

xls
Project No. Date

------- 30-Aug-17
DESIGN CALCULATION SHEET
Sheet No. Computed by

-- of -- --
Checked by Approved by
Subject ------------------------------
-- _
Building Design of Beam Ledge
DESIGN OF BEAM LEDGE ACCORDING TO ACI 318 - 99
Beam-B1 Ledge
Material Properties
Concrete Cylinder Strength (f 'C) = 350 Kg/Cm2
Steel Yield Stress (fY) = 4200 Kg/Cm2

Section Properties
Total Thickness (h) = 300.00 Cm
af
Depth of Section (d) = 27.00 Cm
Load distance to face of Beam (a) = 10.00 Cm a
Av (F2)
Load distance to center of Stirrup's Leg (a f)= 12.00 Cm Vu As + Ah
a /d= 0.37 < 1 Nuc
(F 1)
Width of bearing plate / pad (W) = 11.50 Cm
Distance between Ledge Loads (S) = 122.00 Cm
h d

Straining Actions 4 F 1 + Cover


Ultimate Vertical Force (Vu) = 10.50 t
Ultimate Normal Force (Nuc) = 2.10 t (Min. = 0.20 Vu = 2.10 t) ACI - 11.9.3.4
Effective width for M & N=(W+5a f )or S = 71.50 Cm
Ultimate Moment (MU)=Vu.af+Nuc(h-d) = 6.99 m. t ACI - 11.9.3
Effective width for Shear =(W+4a) or S = 51.50 Cm
Shear Strength ( f Vn) = 66.48 t ACI - 11.9.3.2.1

Main Reinf. (F 1) Calculations


Reinforcement for Flexure (A f) = 7.03 Cm2 / effective width of 71.50 Cm
Reinforcement for Normal force (A n) = 0.59 Cm2 / effective width of 71.50 Cm ACI - 11.9.3.4
Reinforcement for Shear Friction (Avf) = 2.10 Cm / effective width of
2
51.50 Cm ACI - 11.7.4.1, Eqn. (11-25)
Main Reinforcement (A s) = 0.1066 Cm2 / Cm ACI - 11.9.3.5 & 11.9.5
Total Area of Stirrups (A h) = 0.0492 Cm / Cm
2
ACI - 11.9.4
Provide (A s+A h) = 0.1558 Cm2 / Cm @ F 17 @ 150 mm

Check of bearing Av
Bearing plate length ( L ) = 11.50 Cm (F 2)
Bearing Strength (f Pnb)= f.0.85.f'c.W.L
As + Ah
= 27.54 t > Vu O.K. L df/2 (F 1)

Check of punching d f /2
Assume d f = d df Section
Punching Strength (f Pnp) = 40.30 t > Vu O.K.
L d f/2
Check Required Area for Hanger Reinf. (F 2)
Spacing between Vertical hangers(ss) = 150 mm d f /2
A v = Vu . Spacing (ss) / ( f fy.S) = 0.362 Cm2
Verifying the serviceability af
W
A v = (Vu/1.5) . (SS) / ( 0.5 . Fy).(W+3a) = 1.205 Cm 2 (governs) Plan
d f /2
Av = F 12 @ 150

364515255.xls - Rev. 1.0 Page 2 / 7 08/30/2017


364515255.xls - Rev. 1.0 Page 3 / 7 08/30/2017
Project No. Date

------ 30-Aug-17
DESIGN CALCULATION SHEET
Sheet No. Computed by

-- of -- --
Checked by Approved by
Subject ---------------------
-- _
Building Design of Ledge-End
DESIGN OF BEAM LEDGE ACCORDING TO ACI 318 - 99
Beam-B1 Ledge-end
Material Properties
Concrete Cylinder Strength (f 'C) = 350 Kg/Cm2
Steel Yield Stress (fY) = 4200 Kg/Cm2
Ledge End
Section Properties
Total Thickness (h) = 35.00 Cm
Depth of Section (d) = 30.00 Cm af
Load distance to face of Beam (a) = 10.00 Cm Av (F 2)
Load distance to center of Stirrup's Leg (a f)= a
16.00 Cm
Vu
a /d= 0.33 < 1 As + Ah
Nuc
Width of bearing plate / pad (W) = 10.00 Cm (F 1)
Distance between Ledge Loads (S) = 150.00 Cm
Distance to Ledge end (C) = 15.00 Cm
h d

Straining Actions
Ultimate Vertical Force (Vu) = 19.00 t
4 F 1 + Cover
Ultimate Normal Force (Nuc) = 3.80 t (Min. = 0.20 Vu = 3.80 t) ACI - 11.9.3.4
Effective width for M & N=(W+5a f )or S = 30.00 Cm
Ultimate Moment (MU)=Vu.af+Nuc(h-d) = 3.23 m. t ACI - 11.9.3
Effective width for Shear =(W+4a) or S = 30.00 Cm
Shear Strength ( f Vn) = 43.03 t ACI - 11.9.3.2.1

Main Reinf. (F 1) Calculations


Reinforcement for Flexure (A f) = 3.19 Cm2 / effective width of 30.00 Cm Min. to ACI-10.5
Reinforcement for Normal force (A n) = 1.06 Cm2 / effective width of 30.00 Cm ACI - 11.9.3.4
Reinforcement for Shear Friction (Avf) = 3.80 Cm / effective width of
2
30.00 Cm ACI - 11.7.4.1, Eqn. (11-25)
Main Reinforcement (A s) = 0.1417 Cm2 / Cm ACI - 11.9.3.5 & 11.9.5
Total Area of Stirrups (A h) = 0.0531 Cm / Cm
2
ACI - 11.9.4
Provide (A s+A h) = 0.1949 Cm2 / Cm @ F 19 @ 150 mm

Check of bearing Av
Bearing plate length ( L ) = 15.00 Cm (F 2)
Bearing Strength (f Pnb)= f.0.85.f'c.W.L
As + Ah
= 31.24 t > Vu O.K. L df/2 (F 1)

Check of punching d f /2
Assume d f = d df Section
Punching Strength (f Pnp) = 27.83 t > Vu O.K.
L d f/2
Check Required Area for Hanger Reinf. (F 2)
Spacing between Vertical hangers(ss) = 150 mm d f /2
A v = Vu . Spacing (ss) / ( f fy.S) = 2.661 Cm2
Verifying the serviceability W af
A v = (Vu/1.5) . (SS) / ( 0.5 . Fy).(W+3a) = 3.016 Cm2 (governs) Plan
d f /2
Av = F 20 @ 150

08/30/2017 at 04:50:32 Page 4 Of 7 364515255.xls


08/30/2017 at 04:50:32 Page 5 Of 7 364515255.xls
Project No. Date

---------
DESIGN CALCULATION SHEET
Sheet No. Computed by

-- of -- --
Checked by Approved by
Subject -------------
_
Building Design of Beam Ledge
DESIGN OF BEAM LEDGE ACCORDING TO ACI 318 - 99
Beam-B2 Ledge
Material Properties
Concrete Cylinder Strength (f 'C) = 280 Kg/Cm2
Steel Yield Stress (fY) = 3600 Kg/Cm2

Section Properties
Total Thickness (h) = 20.00 Cm af
Depth of Section (d) = 200.00 Cm Av (F 2)
a
Load distance to face of Beam (a) = 12.00 Cm
Load distance to center of Stirrup's Leg (a f)= Vu
17.00 Cm As + Ah
a /d= 0.06 < 1 Nuc (F 1)
Unit Width of bearing plate / pad (W) = 250.00 Cm
Unit distance of distributed Loads (S) = 250.00 Cm
h d

Straining Actions
4 F 1 + Cover
Ultimate Vertical Force (Vu) = 31.00 t
Ultimate Normal Force (Nuc) = 0.00 t (Min. = 0.20 Vu = 6.20 t) ACI - 11.9.3.4
Effective width for M & N=(W+5a f )or S = 250.00 Cm
Ultimate Moment (MU)=Vu.af+Nuc(h-d) = -5.89 m. t ACI - 11.9.3
Effective width for Shear =(W+4a) or S = 250.00 Cm
Shear Strength ( f Vn) = 2380.00 t ACI - 11.9.3.2.1

Main Reinf. (F 1) Calculations


Reinforcement for Flexure (A f) = -1.21 Cm2 / effective width of 250.00 Cm Min. to ACI-10.5
Reinforcement for Normal force (A n) = 2.03 Cm2 / effective width of 250.00 Cm ACI - 11.9.3.4
Reinforcement for Shear Friction (Avf) = 7.24 Cm / effective width of
2
250.00 Cm ACI - 11.7.4.1, Eqn. (11-25)
Main Reinforcement (A s) = 0.6222 Cm2 / Cm ACI - 11.9.3.5 & 11.9.5
Total Area of Stirrups (A h) = 0.3071 Cm / Cm
2
ACI - 11.9.4
Provide (A s+A h) = 0.9293 Cm2 / Cm @ F 49 @ 200 mm
Big Bar Diameter
Check of bearing Av
Bearing plate length ( L ) = 10.00 Cm (F 2)
Bearing Strength (f Pnb)= f.0.85.f'c.W.L
As + Ah
= 416.50 t > Vu O.K. L df/2 (F 1)

Check of punching d f /2
Assume d f = d df Section
Punching Strength (f Pnp) = 2021.49 t > Vu O.K.

Check Required Area for Hanger Reinf. (F 2)


Spacing between Vertical hangers(ss) = 200 mm
A v = Vu . Spacing (ss) / ( f fy.S) = 0.810 Cm2
Verifying the serviceability W
A v = (Vu/1.5) . (SS) / ( 0.5 . Fy). (W) = 0.919 Cm2 (governs) Plan

Av = F 11 @ 200

08/30/2017 at 04:50:32 Page 6 Of 7 364515255.xls


08/30/2017 at 04:50:33 Page 7 Of 7 364515255.xls