You are on page 1of 16

PORTABLE TYPE

ULTRASONIC FLOWMETER (PORTAFLOW-C)


DATA SHEET FSC-2, FSS, FSD
PORTAFLOW-C is a portable type ultrasonic flowmeter
utilizing the transit time measuring method, using a clamp-
on type detector.
It is a compact and lightweight instrument incorporating the
latest electronics and digital signal processing technologies,
realizing high performance and easy operation.

FEATURES
1. Compact and lightweight
The adoption of the latest electronics and digital
signal processing technologies has reduced the size
and weight of the flow transmitter by 30% and 30%, Flow transmitter (FSC)
respectively, in comparison with the Fuji conventional
portable flowmeter (Model FSC). (in comparison to
our existing model)
2. Battery operation
The flowmeter is designed for 12 hours of continu- Detector (FSSC)
ous operation via built-in battery which is recharge-
able in 3 hours with the exclusive power adapter.
3. Full variety of detectors
The flowmeter is suitable for various types of detec-
tors applicable for small to large diameter pipe (pipe
inner diameter 13 to 6000mm) and low to high
Detector for high-temperature(FSSH)
temperature (40 to +200C).
4. High accuracy and high-speed response
The flowmeter is designed for high accuracy 10. Graphic printer connection (option)
(1.0%). Easy recording with the Integral type printer.
Response time is within 1 second. 11. Flow velocity profile measurement (option)
5. Improved anti-bubble characteristic Flow profile may be observed in real time.
Anti-bubble characteristic is greatly improved by
digital signal processing. SPECIFICATIONS
6. Excellent performance and easy operation
Large graphic LCD that is outside but easy to read. Measuring objects
Minimum number of function keys are used for page
Measurement fluid:
selection, allowing easy setting.
Uniform liquid in which ultrasonic
While battery is working, the flowmeter is water waves can propagate.
resistant and tolerates exposure to rain. Turbidity of fluid: 10000 mg/L or less
7. Large capacity storage by SD memory card State of fluid: Well-developed turbulent or laminar
Measured data is periodically stored in SD memory flow in a filled pipe.
card. For example, in the case of 256MB (option), it Fluid temperature: 40 to +200C
can be saved about 1 year measurement date(In case Measuring range: 00.3 to 32m/s
of saving period 30 seconds, 14 kinds of saved data).
Available up to 8MB. Piping conditions
8. Serial communication
Applicable piping material:
Use of a USB port allows easy connection to a per-
Select from carbon steel, stainless
sonal computer. Measured date collection panel and
steel, cast iron, PVC, FRP, copper,
Loader software for PC (standard) which is available
aluminum, acrylic or material of known
for display and change of parameter (site setting) are sound velocity.
prepared. Pipe size: Flow rate measurement
9. Heat quantity (calorie) measurement 13 to 6000mm
Heat quantity (calorie) may be measured by tem- Flow velocity profile measurement
perature input, making energy management easy for 40 to 1000mm
cooling and heating.

EDS6-147a
Date Feb. 14, 2013
FSC-2, FSS, FSD

Lining material: Select from no lining, tar epoxy, Analog output signals:
mortar, rubber, Teflon, pyrex glass or 4 to 20mA DC, one point (load resis-
material of known sound velocity. tance, 600 or less)
Note) No gap allowed between the Instantaneous velocity, instantaneous
lining and the pipe. flow rate or heat quantity (calorie) after
Straight pipe length: scaling.
10D or more upstream and 5D or more Analog input signal:
downstream (D: internal pipe diam- 4 to 20mA DC, one point
eter) (input resistance, 200 or
Refer to Japan Electric Measuring In- less) Total
struments Manufactures Associations 4 to 20mA DC, one point (in- 2 points
standard JEMIS-032 for details. put resistance, 200 or less)
or 1 to 5V DC, one point
Performance specifications Used to input temperature for heat
quantity measurement, etc.
Accuracy rating:
SD memory card: Used for data logger function and
Pipe inner Flow velocity Accuracy
diameter range
recording screen data.
Available up to 8GB (Option256MB)
13 to 50mm 2 to 32m/s 1.5% of rate
0 to 2m/s 0.03m/s Compliant media
50 to 300mm 2 to 32m/s 1.0% to 1.5% of rate SD memory card: speed class 2, 4, 6
0 to 2m/s 0.02 to 0.03m/s SDHC memory card: speed class 4, 6
300 to 6000mm 1 to 32m/s 1.0% to 1.5% of rate Format
0 to 1m/s 0.01 to 0.02m/s FAT16: 64MB to 2GB
Note1) Reference conditions are based on JEMIS-032. FAT32: 4GB, 8GB
Note2) Refer to the 4 pages for the accuracy according to kind Otherwise, reading and saving are
of detector. impossible.
File format
Flow transmitter (Type: FSC) Date logger: CSV file
Power supply: Built-in battery or AC power adapter Screen date: Bit map file
Built-in battery: Exclusive lithium button battery Serial communication:
(5000m Ah) USB port (device* compatible):
Continuous operation time, approx. 12 Mini B receptacle
hours (without printer, back light OFF, Connectable number of Mini B recep-
output current not used and at normal tacles:
ambient temperature (20C)) 1 unit
Recharging time, approx. 3 hours Transmission distance: 3m max.
(power adapter used) Transmission speed: 500kbps
Recharging temperature range: 0 to Data:
+40C Instantaneous velocity, instanta-
Power consumption: Min. 3W and neous flow rate, total value, heat
Max. 16W quantity (calorie) value, error infor-
The consumption varies depending on mation, logger data, etc.
the use conditions. * Device: Connected plug from PC
Power adapter: Exclusive power adapter 90V to 264V Printer (option): To be mounted on top of transmitter
AC (50/60Hz), 70VA or less. unit
LCD: Semi-transmissive color graphic display Thermal line dot printing
240 320 (with back light) Note) When the Chinese display is selected,
Measurement value (instantaneous printing is made in kanji characters.
flow rate, integrated flow rate) and Ambient temperature:
various settings are displayed. 10 to +55C (Without printer)
Excellent visibility even outdoors in 10 to +45C (With printer)
direct sunlight. Ambient humidity: 90%RH or less
LED display: Status display when using AC power Type of enclosure: IP64 (Without printer)
adapter. Enclosure case: Plastic case
DC IN (green): Power supply status Outer dimensions: H210 W120 D65mm (Without printer)
CHARGE (red): Battery charging under- H320 W120 D65mm (With printer)
way Weight: 1.0kg (Without printer)
Operation keypad: 1.2kg (With printer)
11 buttons
(ON, OFF, ENT, ESC, MENU, , , , Various functions
, LIGHT, PRINT) Display language: Selectable from Japanese, English,
Power failure backup: German, French, Spanish or Chinese
Measurement value is backed up by (switchable by key operation).
nonvolatile memory. Clock display function:
Clock backup with lithium battery (ef- Time (year, month, day, hour, minute)
fective term, 10 years or more) display (configurable)
Response time: 1 second Monthly error: about 1 minutes at nor-
mal temperature (20C).
2
Instantaneous value display function: Temperature display function:
Instantaneous velocity, instantaneous Fluid temperature be displayed by cur-
flow rate display (The flow in reverse rent input from temperature transmit-
direction is displayed with minus .) ter.
Numeric value: 10 digits (decimal point Metric system
equals 1 digit) Temperature unit: C or K
Unit: Metric/English system selectable English system
Metric system Temperature unit: F or K
Velocity: m/s Site data storage function:
Flow rate: L/s, L/min, L/h, L/d, kL/d, Max. 32 locations (sites) data (pipe
ML/d, m3/s, m3/min, m3/h, size, material, fluid type and etc) can
m3/d, km3/d, Mm3/d, BBL/s, be stored into built-in non-volantile
BBL/min, BBL/h, BBL/d, memory.
kBBL/d, MBBL/d Damping: 0 to 100sec (every 0.1sec) configurable
English system for analog output and velocity/flow
Velocity: ft/s rate display
Flow rate: gal/s, gal/min, gal/h, gal/d, Low flow cut: Equivalent to 0 to 5m/s
kgal/d, Mgal/d, ft3/s, ft3/min, Output setting function:
ft3/h, ft3/d, kft3/d, Mft3/d, Current output scaling, output type,
BBL/s, BBL/min, BBL/h, burnout setting and calibration
BBL/d, kBBL/d, MBBL/d Serial communication function:
Total value display function: Instantaneous velocity, instantaneous
Display of forward or reverse total flow rate, total value, heat flow, er-
(reverse is displayed as minus) ror information, received waveform,
Numeric value: 10 digits (decimal point analog input, velocity profile data,
is corresponding to 1 digit) logger data, etc. may be downloaded
Unit: Metric/English system selectable to personal computer.
Metric system Logger function: Instantaneous velocity, instantaneous
Flow rate total: mL, L, m3, km3, Mm3, flow rate, total value, heat flow, error
mBBL, BBL, kBBL information, received waveform, ana-
English system log input, velocity profile date can be
Flow rate total: gal, kgal, ft 3, kft3, Mft3, saved in a SD memory card.
mBBL, BBL, kBBL, ACRE-ft Waveform display function:
Consumed heat quantity (calorie) display function: Bi-directional received waveforms may
Display of consumed heating medium be displayed.
Metric system Graph display function:
Heat flow: MJ/h, GJ/h Flow rate trend graph may be dis-
Total heat quantity: MJ, GJ played.
English system Printing function (option):
Heat flow: MJ/h, GJ/h, BTU/h, kBTU/h, Hard copy output of a screen
MBTU/h, kWh, MWh Periodic printing (type: text, graph)
Total heat quantity: Logger date (type: text, graph)
MJ, GJ, BTU, kBTU, MBTU, Flow velocity profile measurement (option):
kW, MWh Flow velocity profile may be observed
J : Joule in real time using the exclusive detec-
BTU : British thermal unit tor (option).
W : Watt (Refer to page 5 for details.)
Computation function of consumed heat quantity (calorie):
This function calculates the heat Detector (Type: FSS)
quantity received and sent with liquid
Type of detector:
(water) in cooling and heating.
Classification Type Internal pipe Fluid temperature
diameter (mm)
Consumed heat quantity Middle diameter FSSC 50 to 1200 -40 to 120C
q = K Q (T1T2)
Converter
K : heat quantity (calorie)
Small diameter FSSD 13 to 300 -40 to 100C
conversion factor Large diameter FSSE 200 to 6000 -40 to 80C
(For heating K = 4.123,
Temperature
For cooling = 4.186) High temperature FSSH 50 to 400 -40 to 200C
sensor
Mounting method: Mounting on outside of pipe
T1: Fluid temperature Sensor mounting method:
(inlet)
V or Z method
exchanger

Signal cable: Exclusive coaxial cable, 5m (Included with


source

Heat
Heat

FSC)
Converter Connection method:
Detector Transmitter side
Temperature
sensor
(type : FSS) Exclusive connector
Detector side (FSSE)
T2: Fluid temperature (outlet) Q: Flow rate of the fluid Screw terminal
Others: BNC connector
3
FSC-2, FSS, FSD

Ambient temperature:
20 to +60C
MEASURING PRINCIPLE
Ambient humidity: With ultrasonic pulses propagated diagonally between the
FSSE 100%RH or less upstream and downstream sensors, flow rate is measured by
Other 90%RH or less detecting the time difference obtained by the flow of fluid.
Type of enclosure: Detector
Upstream sensor
FSSC IP65
(When waterproof BNC con-
nector is provided) Output
D Flow signal
FSSE IP67 t2 trans-
Flow t1 mitter
Others IP52 velocity V
Water-proof treatment type IP68
Downstream sensor
(Submerged resistant struc-
ture for 5 days)
Material of detector: MOUNTING OF DETECTOR
Classification Type Sensor Rail material PZT oscillator Plastic wedge
case Pipe
Small diameter FSSC Plastic Aluminum alloy + Plastic
Middle diameter FSSD Plastic Aluminum alloy + Plastic Lining
Large diameter FSSE Plastic
High temperature FSSH SUS304 Aluminum alloy

Material of mounting belt/wire:


Detector type Dimensions Material
6th digit
A 1.5mX2 SUS304
CONFIGURATION DIAGRAM
(1) When V method is used for mounting
B 3.0mX1 Plastic cloth belt
C 1.0mX4 SUS304 Cable

D Inner pipe diam.<1500mm SUS304


Detector
E Inner pipe diam.<6000mm SUS304
4 to 20mA

transmitter
DC
Extension cable(option):

Flow
Extended when the length of the detec-
tor signal cable is not sufficient.
Length: 10m, 50m (2) When Z method is used for mounting
Cable

Detector
transmitter

4 to 20mA
DC
Flow

DETECTOR SELECTION GUIDE (ACCURACY % of rate)


Inner diameter of piping [mm]
Mounting
TYPE
method 13 25 50 100 150 200 250 300 400 600 1200 3000 6000

V*2) 1.5
to 2.5 1.0
FSSD
Z *1)
1.0

V 1.5 1.0
FSSC
Z 1.0

V 1.5 1.0
FSSE
Z 1.5 1.0

V 1.0
FSSH
Z*1) 1.0

*1) When FSSD or FSSH is mounted using the Z method, guide rail (option) is required additionally.
*2) For the pipe inner diameter of 13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness.
When the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%.
<Description of the table> Required min. pipe thickness (fluid: water) (Unit: mm)
It shows pipe thickness of each material that the sensor mounting Steel pipe 2.15 or more FRP 3.21 or more
size is to be 0.0mm, when fixing a pipe. If the fluid is the one other Stainless pipe 1.87 or more Ductile cast iron 2.15 or more
than water, and if the sound velocity of fluid is faster than the one PVC pipe 3.69 or more PEEK 3.69 or more
of water, the sensor mounting size is to be 0.0mm or more. Copper pipe 3.82 or more PVDF 3.69 or more
Cast-iron pipe 2.98 or more Acrylic pipe 2.90 or more
Aluminum pipe 1.99 or more Polypropylene 3.69 or more

4
FLOW VELOCITY PROFILE DISPLAY FUNCTION Measurement principle
(OPTION) <Pulse Doppler method>
Ultrasonic pulses are transmitted through the fluid flow.
Flow velocity profile can be observed in real time using Entrained bubbles and microscopic particles within the
the dedicated detector from the outside. It is specifiable fluid create frequency phase shifts (Doppler effect.) The
by the code symbol of flow transmitter. resulting doppler shifts are integrated across the inside
pipe diameter cross section. The resulting profile curve
is a real-time dynamic display of the flow profile within
APPLICATION the pipe.
Pulse Doppler method is applicable to observe flow velocity
profile in real time, display the flow status in the pipe, and Sensor 1 (FSD)
decide the appropriate measurement location. Also, it can
be used for diagnosis of flow and laboratory test.
Air Flow
bubbles
SPECIFICATIONS Reflection
Sensor 2
Measuring fluid: Uniform liquid in which ultrasonic (FSD)
waves can propagate.
Flow Flow
Turbidity of fluid: Axisymmetric flow in a filled pipe. velocity velocity
Fluid temperature: Profile 2 Profile 1
Flow velocity
40 to +100C (FSDP2)
40 to +80C (FSDP1,FSDP0)
Air bubble quantity: Piping wall Center Piping wall
0.02 to 15Vol% (Velocity is 1m/s) The above shows an example when using two sensors.
Pipe size: Small type sensor : 40 to 200mm
One detector displays the flow velocity profile for a ra-
Middle type sensor :100 to 400mm
dius.
Large type sensor :200 to 1000mm
Measurement range:
0 to 0.3: Maximum Velocity (de-


pending on the pipe diameter)
Refer to chart, table.1.
Block diagram
Note) This function is to observe flow (1) Using one sensor
velocity profile, and it may be different
Cable
from actual flow rate. Power
supply
Sensor (FSD)
DETECTOR FOR FLOW VELOCITY PROFILE Flow
MEASUREMENT (TYPE: FSDP) Transmitter

Mounting method:
Mounting on outside of existing pipe
Ambient temperature: 20 to +80C
(2) Using two sensors
Ambient humidity: 100% RH or less
Type of enclosure: Power
Cable supply
IP67 (with waterproof BNC connector Sensor (FSD)
provided.)
Material: Sensor housing: PBT
Flow
Guide frame: Aluminum alloy Transmitter
Mounting belt: Plastic cloth belt/stain-
less belt Sensor (FSD)

5
FSC-2, FSS, FSD

Table.1 PC Loader software


Maximum measurement range of Pulsed Doppler method. Equipped as standard
When nominal thickness of a stainless pipe of pipe material PC/AT compatible machines. (Operation on custom built
is Sch20s and the fluid is water, the maximum measure- PCs or shop-brand PCs cannot be guaranteed.)
ment range varies depending on the outer diameter of pipe, Major functions: Performs parameter (site setting)
nominal thickness, material, or fluid type. display /change of the main unit and
<Maximum measurable flow velocity> <Maximum measurable flow rate> collects measured date.
Unit: m/s Unit: m3/h Instantaneous velocity, instantaneous flow
Diameter FSDP2 FSDP1 FSDP0 FSDP2 FSDP1 FSDP0 rate, total value, error information, received
40A 6.56 33.6 waveform, analog input, logger data, etc.
50A 6.52 52.7 may be downloaded in a personal computer.
65A 5.31 72.1 O/S: Windows2000/XP/Vista* or Windows 7 (Home Pre-
80A 4.65 86.5
mium, Professional)
90A 4.12 102
Memory requirement: 128MB or more
100A 3.69 7.25 118 231
125A 3.08 6.08 147 289
Disk unit: Windows2000/XP/Vista or Windows 7 (Home
150A 2.63 5.20 179 354 Premium, Professional)-compatible CD-ROM
200A 2.04 4.05 7.77 239 474 908 drive
250A 3.30 6.38 604 1168 Hard disk drive capacity: Free space of 64MB or more
300A 2.78 5.41 735 1428
350A 2.51 4.90 820 1598 * Windows Vista: Use it in basic mode.
400A 2.20 4.31 951 1858 It is not available for Windows Aero.
450A 3.80 2118
500A 3.48 2358
550A 3.17 2618
600A 2.91 2879
650A 2.71 3096
700A 2.52 3357
750A 2.35 3618
800A 2.21 3879
850A 2.08 4140
900A 1.97 4400
1000A 1.77 4902

CODE SYMBOL
<Flow transmitter> <Detector>
1 2 3 4 5 6 7 8 9 10 11 (for transit time)
F SC 2 - 0 Description 1 2 3 4 5 6 7 8 9 10

<Specification> F SSC1 1 Description


S Standard <Senser type>(4th digits)
<Converter> C 50 to 1200mm
1 Basic system <Guide rail>(5th digits)
2 Basic system + Printer 1 Provided (Extendable rail type)
<Flow velocity profile measurement>
<Mounting belt>(6th digits) *2
0 None Y None
1 Provided (detector to measure flow A Stainless belt (1.0m2)
velocity profile is separately required.) B Plastic cloth belt (3m1)
<Power adapter> C SS belt fasten with screws (1.0m4)
A AC power + power cord (125V AC) for D Wire 1500mm
Japanese and North American use <Acoustic coupler> (7th digit) *1
B AC power + power cord (250V AC) for Y None
European and Korean use B Silicone-free grease (HIGH-Z)
C AC power + power cord (250V AC) for C Silicone grease (G40M)
Chinese use
<Water-proof treatment>(9th digit)
2 Modification No. Y None
<SD memory card> B Provided (with signal cable 10m)
0 None *Submersible in water for 5 days
1 Provided (256MB) <Tag plate> (10th digit)
Y None
<Bound instruction manual/Language>
A Provided
Y None (Factory-set language: English)
J Provided/Japanese *1: Normally select silicone grease as acoustic coupler. Silicone grease is
(Factory-set language: Japanese) tube (100g).
E Provided/English Select silicone-free grease for semiconductor manufacturing
(Factory-set language: English) equipment or the like that is vulnerable to silicone. The silicone-free
C Provided/Chinese grease is water-soluble and, therefore, cannot be used in environment
(Factory-set language: Chinese) exposed to water or on piping subjected to a condensation. Since the
(Note1) Instruction manual contained in CD grease does not set, a periodic maintenance (cleaning, refilling every
is the standard attached article. about 6 months at normal temperature) is necessary.
(Note2) You can change the language by *2: Please refer to the table 1 to serect the mounting belt at 6th digits.
key operation. [Table 1] How to select at 6th digits.
Mounting method 300mm 600mm 1200mm
V method B, A or C C D
Z method C D D

6
CODE SYMBOL OPTIONAL ITEMS
Name Specifications Arrange-
<Detector> ment No.
(for flow velocity profile measurement) 1 Battery Special type Li-ion battery ZZP*TK7N6384P1
1 2 3 4 5 6 7 8 (7.4V, 2500mAh) *Order in two pairs.
F SD 0 Y 1 Description 2 AC power Special type power adapter and
<Kind> adapter 90 to 264V AC, 50/60Hz
P2 Small type (40 to 200mm) ZZP*TK7N6380C4
P1 Middle type (100 to 400mm)
P0 Large type (200 to 1000mm)
<Terminal mold> 3 Power code Japan, North America:125V AC 2m ZZP*TK7N6621P1
0 None Europe, Korea: 250V AC 2m ZZP*TK7N6608P1
China: 250V AC 2m ZZP*TK7N6609P1
<Structure>
Y General use 4 Printer To be mounted on top of converter ZZP*TK4J2634C1
1 Modification No. Thermal serial dot system (8 x 384
dot)

5 Printer roll Maker: SEIKO I SUPPLY Co. Ltd. ZZP*TK7N6381P1


paper Type: TP-211C-1
SCOPE OF DELIVERY Specifications: Thermal roll paper
Width: 58mm48mm
<Flow transmitter : FSC> 6 Silicone Maker: Shin-Etsu Chemical Co., Ltd.
Name of unit Scope of delivery grease Type:
1 Basic system 1) Conversion unit For standard use G40M, 100g ZZP*45231N5
2) Power adapter and For silicone free 100g ZZP*TK7M0981P1
Power connector conversion cord For high temperature KS62M, 100g ZZP*TK7P1921C1
3) Power cord 7 Signal cable Special type signal cable, 5m 2
4) Analog input/output cord (1.5m) (connector on both - sides) ZZP*TK7N7795C1
5) USB cable (1m)
6) Carrying case
7) Strap 8 Extension Special type coaxial cable with BNC
8) Special type signal cable (5m 2) signal cable connector
9) C D-ROM (Instruction manual and 10m 2 ZZP*TK468664C3
50m 2 ZZP*TK468664C4
Loader software for PC)
9 Analog 6-core cable, 1.5m, with connector ZZP*TK4J2639C1
2 Option 1) Printer unit + rolled paper (1 roll)
input/output
2) SD memory card (256MB) cable
3) Bound instruction manual (including
a detector)

<Detector : FSS, FSD>


10 Mounting Plastic cloth belt ZZP*TK7G7979C1
Name of unit Scope of delivery belt /wire Stainless wire
1 Detector for propa- 1) Sensor unit Nominal diameter
gation time differ- 2) Signal cable conversion code 200 to 500mm ZZP*TK7G7980C1
ence (FSS) (included with FSSE) 200 to 1000mm ZZP*TK7G7980C2
3) Mounting belt/wire 200 to 2000mm ZZP*TK7G7980C3
200 to 3000mm ZZP*TK7G7980C4
4) Silicone grease (Article specified)
200 to 6000mm ZZP*TK7G7980C5
2 Detector for flow 1) Detector unit Stainless steel belt ZZP*TK7P1943C1
v e l o c i t y p r o f i l e 2) Mounting belt/wire
11 Guide rail Mounting bracket material: ZZP*TK4J5917C3
(FSDP) 3) Silicone grease (100g) for high- Aluminum alloy+SUS304
Note 1) Silicon grease is for filling a gap between a detector and a temperature For FSSH
pipe joint area. It is provided with a detector. sensor
Since silicon grease does not become hardened, if you use (In mounting
it in the long term, periodic maintenance is required. (Under by the Z
the condition of room temperature, semiannual cleaning and method)
refill is recommended.) 12 Guide rail for Mounting bracket material: ZZP*TK4J5917C1
Note 2) When you order a detector alone, an instruction manual is small type Aluminum alloy+plastic
not provided. Please request, if necessary (Onerous). detector For FSSD3 (L=540mm)
(In mounting
by the Z
method)
13 SD memory Maker: Apacer Technology, Inc. ZZP*TK7N6386P1
card Type: AP-ESD256TPSR
Capacity: 256MB
14 USB cable Maker: Sunwa Supply Inc. ZZP*TK7N6622P1
Type: KU-AMB510
Specifications: Mini USB cable
(1.0m)
15 Signal cable M4 clamp terminal / BNC jack, ZZP*TK4K6304P1
conversion L=150mm
cord

7
FSC-2, FSS, FSD

Diagram To connect signal cables for FSSC, FSSD, FSSH, FSDP2, FSDP1, FSDP0
BNC
connector

Printer Detector
(option)

Signal cable To connect signal cables for FSSE


Conversion
cord
Detector input BNC connector
PORTAFLOW

Detector
(the downstream side)
Flow
transmitter Detector input
(the upstream side)
ON OFF
ESC Analog input/output cable
AO analog output 4 to 20mA DC
FEED

ENT
Print
MENU
AICH1 analog input 4 to 20mA DC or 1 to 5 V DC
AICH2 analog input 4 to 20mA DC
CHARGE DC IN

PC
SD Power connector AC90 to 264V
Conversion cord
SD memory Power cord
card AC power adaptor

USB cable for use AC adaptor

To connect PC

Conditions on straight pipe


(D: Nominal diameter of pipe)
Type Length of upstream straight pipe Length of downstream straight pipe

L 5D
10D or more

L 10D
90 bend

Detector
10D or more

L 10D
L 50D
Tee

10D or more
or more

L 30D L 5D
0.5D

Diffuser
D

1.5D or more

L 10D L 50D

Contraction pipe

L 30D L 10D

Valve

Flow controlled upstream Flow controlled downstream

Isolation valve
Check valve
L 50D
Pump
P

Note) Source: Japan Electric Measuring Instruments Manufacturers' Association (JEMIS-032)

8
OUTLINE DIAGRAM (Unit:mm)
Flow transmitter

1201.8 651.8

2-M4, Depth5 (both sides)

PORTAFLOW
Sensor (downstream)

DOWNSTREAM

SENSOR
UPSTREAM
2102.5

Sensor (upstream)

AI/AO
DC12V
ON OFF
ESC
FEED
Analog input/output

ENT
Print
MENU DC power input
CHARGE DC IN

Power switch

SD memory card slot USB port

Weight : Approx. 1.0kg

9
FSC-2, FSS, FSD

OUTLINE DIAGRAM (Unit:mm)


Flow transmitter (with printer)

1201.8 651.8

Printer

2-M4, Depth5 (both sides)


Approx. 3204.5

PORTAFLOW
Sensor (downstream)
DOWNSTREAM

SENSOR
UPSTREAM

Sensor (upstream)
AI/AO

Analog input/output
DC12V

ON OFF
FEED
ESC

ENT
Print DC power input
MENU
CHARGE DC IN

Power switch

SD memory card slot USB port

Weight : Approx. 1.2kg

10
OUTLINE DIAGRAM (Unit:mm)
4802

SPACING: 0 to 300

inch 6 5 4 3 2 1 20 40 60 80 100 120 140 160 mm

mm 160 140 120 100 80 60 40 20 1 2 3 4 5 6 inch

BNC connector
Scale (inch) Scale (mm)
53
BNC CONN. Lock nut

88max.
Sensor unit

54
Rail end Tag plate Name plate Guide rail
Extended rail

<Shipment style (V method)>

Type.
Mfd.
(880)

L
700max.
400max. 240

inch 6 5 4 3 2 1 20 40 60 80 100 120 140 160 mm

mm 160 140 120 100 80 60 40 20 1 2 3 4 5 6 inch

Absorber unit
100 100 100 100

Ser.No.
Extended rail

Made in Japan

<Extended style (Longest, V method)>


Frame
240 240

Rail end (Accessories)

<Sepalate style (Z method)>


(H)

Detecter : Type FSSC

W1

Weight
Type Diameter (mm) L H W Approx. (kg)
Straight plug BNC Connector
FSDP2 40 to 200 2601.2 70 57 0.8

FSDP1 100 to 400 2601.2 72 57 0.9


(2.4)

+100 FSDP0 200 to 1000 3502.0 90 85 2.0


5000 -0
Detector FSDP (Detector for flow velocity profile measurement)

Signal cable Clip

Straight plug
(12.3)

AO
AI ch1
AI ch2
(5)

+100
1500 -0 1005

Weight : approx. 0.1kg

Code color Clip color Mark


Black (BK) Red (R) (+)
AO
White (W) Black (BK) ()
Red (R) Red (R) (+)
AI ch1
Green (G) Black (BK) ()
Yellow (Y) Red (R) (+)
AI ch2
Brown (BN) Black (BK) ()

Analog input/output cable


11
FSC-2, FSS, FSD

Detector for special application 1) detector for small diameter type


Pipe size: 13 to 100mm (300mm max.)
Fluid temperature: 40 to 100C
Type: FSSD 1-Y

Specification
Sensor frequency: 2MHz
Mounting method: V method, Z method (FSSD3)
Fluid temperature: 40 to 100C CODE SYMBOL
Applicable pipe material: PVC, SS, carbon steel pipe, <Detector>
copper pipe, aluminum pipe, etc. 1 2 3 4 5 6 7 8 9 10

[In case lining is removed from the pipe, Measurement F S SD1 1 Description
can not be conducted] <Senser type>(4th digits)
D 13 to 100mm
Rated accuracy of combination with the flow transmitter
<Guide rail>(5th digits)
(Applicable piping: plastic, metal pipe)
1 Provided (L=320mm)100mm
Internal diameter Velocity Accuracy 3 Iong rail (L=540mm)300mm
(mm) <Mounting belt>(6th digits)
Y None
13 to 50 2 to 32m/s 1.5% to 2.5% of rate A Stainless belt (1.5m2)
0 to 2m/s 0.03 to 0.05m/s B Plastic cloth belt (3m1)
50 to 100 2 to 32m/s 1.0% of rate C SS belt fasten with screws (1.0m4)
(300) 0 to 2m/s 0.02m/s <Acoustic coupler> (7th digit)
Y None
A
Mounting belt: according to specified code of symbol. Silicon rubber (KE348)
B Silicone-free grease (HIGH-Z)
Material: PBT, guide rail: aluminum alloy + plastic C Silicone grease (G40M)
Type of enclosure: IP52 <Water-proof treatment>(9th digit)
Acoustic coupler: according to specified code of symbol. Y None
<Tag plate> (10th digit)
Mass: 0.6kg, 0.8kg Y None
A Provided

OPTIONAL ACCESSORIES
Name Drawing No.
Sillicon grease (GM40M) ZZP*45231N5
Sillicon-free grease (HIGH-Z) ZZP*TK7M0981P1

Scope of delivery
D
 etector, acoustic coupler and set of the mounting belt
according to specified code of symbol
OUTLINE DIAGRAM (unit: mm)
<Detector>
Saddle Saddle
Scale(inch) Scale(mm)
Connector
Connector
mm

Scale Scale
(inch) (mm)
Distance between two

Name prate
sensors 0 to 133

Spacing: 0 to 348
3202

Lock nut
5402

Element holder

Lock nut
Cursor
inch

Element holder

Cursor
36
90 max.

360.5
90max.

52.50.5

52.50.5
Weight : Approx. 0.6kg Weight : Approx. 0.8kg

Small diameter sensor: FSSD1 Detector FSSD3


12
Detector for special application 2) detector for high temperature
Pipe size: 50 to 400mm
Fluid temperature: 40 to 200C
Type: FSSH11-Y

Specification
Sensor frequency: 2MHz
Mounting method: V method (50 to 250mm) or Z method
CODE SYMBOL
(150 to 400mm)
<Detector>
Fluid temperature: 40 to 200C 1 2 3 4 5 6 7 8 9 10

A pplicable pipe material: PVC, SS, carbon steel pipe, F S SH1 1 Description
copper pipe, aluminum pipe,etc. <Senser type>(4th digits)
H 50 to 400mm (-40 to 200C)
[In case lining is removed from the pipe, Measurement
<Guide rail>(5th digits)
can not be conducted]
1 Provided
Rated accuracy of combination with the flow transmitter
<Mounting belt>(6th digits)
(Applicable piping: plastic,metal pipe) Y None
A Stainless belt (1.5m2)
Internal diameter Velocity Accuracy C SS belt fasten with screws (1.0m4)
(mm) <Acoustic coupler> (7th digit)
50 to 300 2 to 32m/s 1.0% of rate Y None
0 to 2m/s 0.02m/s D High-temperature grease (KS62M)
300 to 400 0.75 to 32m/s 1.0% of rate <Water-proof treatment>(9th digit)
Y None
0 to 0.75m/s 0.0075m/s
<Tag plate> (10th digit)
Y None
Mounting belt: according to specified code of symbol.
A Provided
Material: sensor housing: SUS304
guide rail: SUS304 + aluminum alloy
Type of enclosure: IP52
Acoustic coupler: according to specified code of symbol. OPTIONAL ACCESSORIES
Mass: 1.6kg Name Drawing No.
Guide rail for high-temperature sensor ZZP*TK4J5917C3
(Z method)
High-temperature grease(KS62M) ZZP*TK7G7983C1
OUTLINE DIAGRAM (unit: mm)
<Detector>
Connector Saddle

Scale(inch)
Scope of delivery
Scale(mm)
D
 etector, acoustic coupler and set of the mounting belt
according to specified code of symbol

Name plate
two sensors 0 to 330
Distance between

5302

Lock nut

Element holder

Cursor

26 330.5
90max.
205max.

441

High-temperature sensor: FSSH

13
FSC-2, FSS, FSD

Detector for special application 3) detector for large diameter type


Pipe size: 200 to 6000mm
Fluid temperature: 40 to 80C
Type: FSSE11-Y

Specification
Sensor frequency: 0.5MHz
CODE SYMBOL
Mounting method: V or Z method
<Detector>
Fluid temperature: 40 to 80C 1 2 3 4 5 6 7 8 9 10

A pplicable pipe material: PVC, SS, carbon steel pipe, F SSE1 1 Description
copper pipe, aluminum pipe,etc. <Senser type>(4th digits)
E 200 to 6000mm
* In case lining is removed from the pipe, Measurement <Guide rail>(5th digits)
can not be conducted 1 Provided
Also applicable to water-proof type according to specified <Mounting belt>(6th digits)
code of symbol (submerged resistant structure for 5days Y None
D Wire 1500mm
including 10m cable) E Wire 6000mm
Rated accuracy of combination with the flow transmitter <Acoustic coupler> (7th digit)
(Applicable piping: plastic, metal pipe) Y None
A Silicon rubber (KE348)
Internal diameter Velocity Accuracy B Silicone-free grease (HIGH-Z)
C Silicone grease (G40M)
(mm)
200 to 300 2 to 32m/s 1.5% of rate <Water-proof treatment>(9th digit)
Y None
0 to 2m/s 0.03m/s B Provided (with signal cable 10m)
300 to 1200 0.75 to 32m/s 1.5% of rate <Tag plate> (10th digit)
0 to 0.75m/s 0.0113m/s Y None
1000 to 6000 1 to 32m/s 1.0% of rate A Provided

0 to 1m/s 0.02m/s

Mounting belt: according to specified code of symbol. OPTIONAL ACCESSORIES


Material: Sensor housing PBT, Sensor cover SUS304 Name Drawing No.
Type of enclosure: IP67 Wire rope for mounting the sensor
Spring ZZP*TK745007P1
(silicon rubber is filled up on the terminal block when con- Wire rope (up to 500mm) ZZP*TK464686C1
necting work) Wire rope (up to 1000mm) ZZP*TK464686C2
Acoustic coupler: according to specified code of symbol. Wire rope (up to 1500mm) ZZP*TK464686C3
Mass: 1.2kg Wire rope (up to 3000mm) ZZP*TK464686C6
Wire rope (up to 6000mm) ZZP*TK464686C13
Sillicon grease (GM40M) ZZP*45231N5
OUTLINE DIAGRAM (unit: mm) Sillicon rubber (KE348W) ZZP*45735N2
<Detector> Sillicon-free grease (HIGH-Z) ZZP*TK7M0981P1

Name plate
Scope of delivery
D etector, acoustic coupler and set of the mounting belt
according to specified cord of symbol
841

Signal cable conversion cord


114
<Signal cable conversion cord>
4.3 Cable BNC Connector
781
Wire rope
Sensor
8

Mounting spring
150
671

19

Large sensor: FSSE

14
Checked items before purchase
Following conditions may cause failure of the measurement
or to reduce the accuracy by this flow meter.
Please consult and ask Fuji Electric for checking with actual
equipment previously if you have hard to judge the appropri-
ate application.

1)Fluid
I f fluid contains a large amount of bubbles (approx.
12vol% or more at 1m/s flow rate)
If fluid has bad turbidity 10000(mg/L) or more,
If fluid contains slurry or solid materials (about 5wt%)
If flow rate is low Reynolds No.10000 or less,
(reference: flow rate 5m3/h with 100mm)
If it is circulating oil, liquid medicine of low concentration,
waste liquid and hot spring,
2)Pipe
If inside pipe is rusty carbon steel pipe,
If inside pipe having adhering substances and sediment
If outer surface of cast-iron pipe is rough,
If pipe wall is tick such as ruinous pipe, (PP material
15mm or more, PVDF material 9mm or more)
If it is SGPW pipe,
If lining pipe is removed from pipe,
If it is rubber pipe,
3) Length of the straight pipe
For accurate measurement, straight pipes are needed
between up and down stream side of the measuring part.
Please meet the straight pipe conditions according page2.

Caution on use
1) Do not damage the sensor or signal mounted on the pipe.
2) Make sure to fill the fluid inside the pipe to measure .
3) When you use horizontal pipe, it is recommended to install
the sensor horizontally.
4) When you use the grease as acoustic coupler to install
the sensor for outdoor use, it is recommended to install
the waterproof cover to prevent from the degradation.

15
FSC-2, FSS, FSD

Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.

International Sales Div


Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/

Information in this catalog is subject to change without notice. Printed in Japan

You might also like