Ebb Consulting, Inc. RADOVAN FELTL tel.

919-389-6339

Project: Augusta Trasit Operations and Maintenance Facility total dampproofing/air barrier (sf): 1,750
Location: Augusta, GA total crystalline waterproofing (sf): 1,270
Bid Date: Friday, May 26, 2017 total below grade waterproofing (sf): 1,620
architect: Wendel total horizontal wp/deck coating (sf): 1,840
drawings dated: 10-Apr total hot-applied wp/paver system (sf):
addenda viewed: one thru three total building joint sealant (lf): 20,050
drawings graded: C total seismic/expansion joints (lf):
alternates: none total head of wall firestopping/side (lf): 920
source (project): see bidders below project estimate cost: $233
source (plans): isqft list of bidders:
submit bids to: see bidders below cost of drawings: $20 total cost: $253

pricing information:
quantity LF/SF
section / key detail line item description and location, joint size # units / Max H / rating unit total

SECTION 071416 - COLD FLUID APPLIED WATERPROOFING warranty: 5 years


(WR Grace Procor or = by Carlisle, Neogard or WR Meadows; protection/drainage board as recommended)
BUILDING A
13,14/s300 CIP chassis wash pit walls, waterproofing 250
17/s300 CIP lift pit walls, waterproofing 720
12/a450 CIP foundation/retaining walls at step in slab elevation 450

BUILDING B
5/s103 CIP re-claim pit walls, waterproofing 200

SECTION 071616 - CRYSTALLINE WATERPROOFING warranty: 5 years


(Xypex, BASF, Euclid or =; apply per manufacturer)
BUILDING A
spec CIP chassis wash pit walls and slab, waterproofing 300
spec CIP lift pit walls and slab, waterproofing 730

BUILDING B
spec CIP chassis wash pit walls and slab, waterproofing 240

SECTION 071800 - TRAFFIC COATINGS

Augusta Transit Maintenance and Operations, Augusta, GA Page 1 of 4 9/10/2017


Ebb Consulting, Inc. RADOVAN FELTL tel. 919-389-6339

(Vehicular: Neogard Autogard FC or =; pedestrian: Pedagard M or =; Carlisle, Degussa or Tremco listed)


BUILDING A
spec Mechanical and electrical room floors 1,000

BUILDING B
spec Mechanical and electrical room floors, lube room 840
Note: specs refer to these rooms to receive traffic coating, finish schedule shown concrete hardener only. Spec could be copied from a different project by Architect.

SECTION 072715 -NON-BITUMINOUS SELF-ADHERING SHEET AIR BARRIERS


(Vapor-Permeable Non-Bituminous Sheet: Minimum 20-mil by Grace, Carlisle or VaproShield)
Qualifications: applicator trained and approved by manufacturer.
BUILDING A
Sheet flashing for fluid applied air barrier below, in linear feet 350

SECTION 072726 - FLUID-APPLIED MEMBRANE AIR BARRIERS


High-Build, Vapor-Permeable Air Barrier: Synthetic polymer membrane with an installed dry film thickness, according to manufacturer's written instructions, of 35
mils or thicker by Grace, Henry or Tremco)
Qualifications: applicator trained and approved by manufacturer.
BUILDING A
9,10/a451 Exterior wall sheathing at back of parapet wall Max H=20' 1,400
Note: buildings are clad with insulated metal panel, which does not require air barrier, except as shown above.

SECTION 078443 - JOINT FIRESTOPPING


(UL Fire Resistance Directory)
Qualifications: FM Global 4991.
BUILDING A
2/a450 Head of fire-rated CMU wall at metal roof deck 780

BUILDING B
2/a450 Head of fire-rated CMU wall at metal roof deck 140

SECTION 079200 - JOINT SEALANTS warranty: 5yrs/2yrs

Augusta Transit Maintenance and Operations, Augusta, GA Page 2 of 4 9/10/2017


Ebb Consulting, Inc. RADOVAN FELTL tel. 919-389-6339

(exterior: silicone; interior: one part urethane; slab/pavement: one part SL urethane)
BUILDING A
8/a950 Interior CMU wall control joints not rated 350
8/a950 Interior CMU wall control joints one or two hour rated 350
10/a950 Drywall/gypsum board wall at CMU, intersection joints 30
3/a250 Interior CMU wall at tube steel column 80
4/a250 Interior CMU wall at insulated metal panel (IMP) wall, 1.0" 550
11/a450 Metal panel siding (IMP) wall base at foundation 560
1/a451 Metal soffit at wall 480
Exterior hollow metal door frames 13 doors 520
Exterior louvers, exterior perimeter 60
17/a251 Metal canopy/sunshade supports at wall 100
2/s300 Slab on grade control joints 3,280
10/s300 Slab on grade perimeter isolation joints 670
Sidewalk/exterior concrete pavement at building 1,180

BUILDING B
8/a950 Interior CMU wall control joints not rated 130
4/a250 Interior CMU wall at insulated metal panel (IMP) wall, 1.0" 280
11/a450 Metal panel siding (IMP) wall base at foundation 252
Exterior hollow metal door frames 10 doors 350
Exterior louvers, exterior perimeter 20
2/s300 Slab on grade control joints 430
10/s300 Slab on grade perimeter isolation joints 120
Sidewalk/exterior concrete pavement at building

c008 Heavy duty concrete pavement expansion joints 2,600


c008 Heavy duty concrete pavement control/contraction joints 5,400
c008 Heavy duty concrete at curb/gutter, expansion joints 2,260

BIDDERS ON GC: tel fax email

Attaway Construction (706) 868-4000 (706) 868-4000 johnp@attawayconstruction.com

Augusta Transit Maintenance and Operations, Augusta, GA Page 3 of 4 9/10/2017


Ebb Consulting, Inc. RADOVAN FELTL tel. 919-389-6339

SD Cliffton 706-731-0978 lamar@sdcliffton.com

Augusta Transit Maintenance and Operations, Augusta, GA Page 4 of 4 9/10/2017