CES and CESD Arktite Receptacles CESD Cl. I, Div.

1 & 2, Group D*
CES Cl. I, Div. 1 & 2, Groups C, D
2P
Delayed Action Circuit Breaking Explosionproof
Wet Locations
CPH Plugs
Factory Sealed

CES Receptacles with three hubs one on CESD Receptacles with vertical through
each side and one at top and two pipe feed hubs and one pipe plug. Removable
plugs with CPH plug fully engaged. threaded cover at top to facilitate
pulling wires.

CES/CESD Receptacles
Hub
Size Max. Max. Volts at CES CESD
(In.) Circuit Phase HP Amps 60 Cycles AC Cat. # Cat. #
2-wire, /2
1
7 480
1 CES2213 CESD2213
3
/4 3-pole 11/2 30 120 to 240
3-wire, 1 7 480
3
/4 3 CES2214 CESD2214
4-pole 3 30 120 to 240
2-wire, 30 480
11/4 1 3 CES4233 CESD4233
3-pole 60 120 to 240
3-wire, 30 480
11/4 3 5 CES4234 CESD4234
4-pole 60 120 to 240

CPH Plugs with mechanical cable grip and neoprene bushing.

CPH Plugs
Cable Diameter
Max. Max. Volts at
2P

Circuit Phase HP Amps 60 Cycles AC .375 to .875 .500 to .875 .875 to 1.375
2-wire, /2
1
7 480 CPH7713 CPH7913
1
3-pole 11/ 2 30 120 to 240
3-wire, 1 7 480 CPH7714 CPH7914
3
4-pole 3 30 120 to 240
2-wire, 30 480 CPH7733 CPH7933
1 3
3-pole 60 120 to 240
3-wire, 30 480 CPH7734 CPH7934
3 5
4-pole 60 120 to 240
CSA certified units are rated at 600 volts.
*In U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals.

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds 1311
2P CES and CESD Arktite Receptacles CESD Cl. I, Div. 1 & 2, Group D*
CES Cl. I, Div. 1 & 2, Groups C, D
Delayed Action Circuit Breaking Explosionproof
Wet Locations
CPH Plugs Dimensions Factory Sealed

Dimensions
In Inches:

CES CESD
Cat. # a b c d e f g h j Cat. # a b e f g h j
CES2213 CESD2213
CES2214 7 /16
7
4 /8
5
2 /16
3
3 /8
3
2 /4
3
4 /81
/16
5
/32
11
/8
7
CESD2214 7 /8
5
6 /8 3
4 /4
1
5 1 /8
7
/32
11 13
/16
CES4233 CESD4233
12 7 27/8 51/4 43/8 61/8 /16
7
/32
13
11/8 131/2 95/8 61/4 71/4 3 /32
13
13/16
CES4234 CESD4234

CPH
Cat. # a b c
CPH7713 6 23/8 45/16
CPH7913 67/16 23/8 43/4
CPH7714 6 23/8 45/16
CPH7914 67/16 23/8 43/4
CPH7733 73/4 23/4 5
CPH7933 81/8 23/4 53/8
CPH7734 73/4 31/16 5
CPH7934 81/8 31/16 53/8
2P

*In U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals.

1310 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2011 Cooper Crouse-Hinds
CES and CESD Arktite Receptacles CESD Cl. I, Div. 1 & 2, Group D* 2P
CES Cl. I, Div. 1 & 2, Groups C, D
Explosionproof
Delayed Action Circuit Breaking Wet Locations
CPH Plugs Factory Sealed

Applications: Standard Materials:


CES and CESD receptacles with CPH Back boxes Feraloy iron alloy
plugs are used: Receptacle housings 30 ampere
With portable electrically operated copper-free aluminum; 60 ampere
devices such as motor-generator sets, Feraloy iron alloy
compressors, conveyors, portable tools, Plug bodies copper-free aluminum
lighting systems and similar equipment Insulation Krydon fiberglass-
In locations which are hazardous due to reinforced polyester
the presence of flammable vapors or Contacts brass or hard-drawn copper
gases
In damp or corrosive locations Standard Finishes:
At petroleum refineries, chemical and
Feraloy electrogalvanized and
petrochemical plants, and other process
aluminum acrylic paint
industry facilities where similar hazards
exist Copper-free aluminum natural
Krydon material red
Features: Fig. 1 Fig. 2 Brass and copper natural
CES and CESD receptacles are equipped
with a delayed action rotating sleeve Grounding:
which prevents complete withdrawal of NEC article 501 and CEC Part 1 Section
the CPH plug in one continuous 18 require that metal frames or exposed
movement non-current-carrying metal parts of
The delayed action feature permits the portable devices used in hazardous
plug to be used as an emergency push- locations be grounded through an extra
pull switch conductor in the portable cord.
Details of operation are illustrated and CES and CESD receptacles and CPH
described to the right: plugs are provided with an extra
Receptacles are factory sealed to grounding pole for attachment of the
simplify installation and wiring. External grounding wire. In the plugs, provision
seals are not required. is made for attachment of the grounding
wire to the grounding pole. In addition,
The 30 ampere receptacles are
direct connection is provided between
provided with pressure terminals for field
plug and receptacle housings and the
connection. The 60 ampere receptacles
ground pole. In the receptacles,
have flexible leads. Plugs are equipped Fig. 3 Fig. 4 grounding is accomplished through the
with solder terminals.
conduit system.
Two arrangements are provided for the Figure 1 above shows a CES receptacle
3
/4" and 11/4" conduit hubs, as shown assembly with CPH plug fully engaged.
in the listings and dimensions
Interchangeability of Plugs
Figure 2 shows the plug withdrawn until it
see page 1310.
is stopped by the delayed action sleeve. In
with Non-hazardous
this position the circuit has been broken Location Receptacles:
Certifications and and the arc has been snuffed in the CPH plugs can also be used with
Compliances: contact chambers. standard AR and NR receptacles of the
NEC/CEC: same ampere rating, style and number
Figure 3 shows the delayed action of poles, thus permitting portable
CES Class I, Division 1 and 2, receptacle sleeve rotated approximately devices which are suitable for use in
Groups C, D; 45 to allow withdrawal of plug from hazardous locations to be connected to
CESD Class I, Division 1 and 2, receptacle. receptacles in both hazardous and non-
Group D* hazardous areas
ANSI/UL Standard: 1010 Figure 4 shows the plug completely
withdrawn. To accomplish this, the Portable devices for non-hazardous
CSA Standard: C22.2 No. 182.1 areas equipped with APJ and NPJ
delayed action sleeve must be rotated
Arktite plugs cannot be used with CES
counterclockwise. The time required to
and CESD receptacles
actuate the mechanism permits dissipation
of the arc-generated heat before contacts Electrical Rating Ranges:
and arcing chambers are opened to the
2P

30 and 60 amperes
atmosphere. When inserting the plug, the
reverse procedure is followed.

Options:
The following special options are available from the factory by adding the suffix to the Cat. #:
Description Suffix
Special polarity for use where two or more receptacles of the same ampere rating,
style and number of poles are to be installed in the same area for use on different
voltages. Receptacle interior rotated 221/ 2 clockwise when viewed from face and
plug changed to match .................................................................................................. S4

*For U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals.