You are on page 1of 4

Project No.

Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test1

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 300.00 Kg/cm2 = 30.00 MPa
Concrete Modulus of Rupture (fr) = 3.83 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.6E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 7.77 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 60.00 cm Depth of Ten. Reinforcement (d) = 55.00 cm
Breadth of Section (b) = 30.00 cm Depth of Comp. Reinforcement (d') = 5.00 cm
Tension Reinforcement (As) = 8.00 cm2 Compression Reinforcement (As') = 2.62 cm2
Span (l) = 5.00 m
Nutral Axis Depth (z) = 12.86 cm
Gross Moment of Inertia (Ig) = 540000.00 cm4 = 5.40E+09 mm4
Cracked Moment of Inertial (Icr) = 132733.36 cm4 = 1.33E+09 mm4
Cracking Moment (Mcr) = 6.90E+07 N mm = 6.90 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 5.00 m.t = 5.0E+07 N. mm
Bending Moment Due to Live Load only (Ml) = 3.50 m.t = 3.5E+07 N. mm
% of Sustained Load from the Live Load = 50%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 6.75 m.t = 6.8E+07 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 0.6000 cm = 6.000 mm
Deflection due to Live Load (Di)l = 0.4000 cm = 4.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 540000.00 cm4 = 5.40E+09 mm4
Under Sustained Load (Ie)sus = 540000.00 cm4 = 5.40E+09 mm4
Under Dead + Live Load (Ie)d+l = 350712.822 cm4 = 3.51E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 0.6000 cm
Deflection due to Sustained Load (Di)sus = 0.8000 cm
Deflection due to Dead + Live Load (Di)d+l = 1.5397 cm
Deflection due to Live Load (Di)l = 0.9397 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 1.48231 cm For 12 months (Dlong) = 1.03762 cm
For 6 months (Dlong) = 0.88939 cm For 3 months (Dlong) = 0.74116 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.9397 cm < l/180 = 2.7778 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.9397 cm < l/360 = 1.3889 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 2.4220 cm > l/480 = 1.04167 cm
-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by

367505400.xls - Rev. 0 Rectangular Section


large deflections:
(Dlong) + (Di)l = 2.4220 cm > l/240 = 2.0833 cm

367505400.xls - Rev. 0 Rectangular Section


Project No. Date

General 28/4/02
DESIGN CALCULATION
SHEET Sheet No. Computed by

of -- A. HASHEM
Checked by Approved by
Subject Checking
_ _
Building Test2

Calculation of Deflection According to ACI 318M-99


Concrete Compressive Strength (f'c) = 330.00 Kg/cm2 = 33.00 MPa
Concrete Modulus of Rupture (fr) = 4.02 MPa (Eq. 9-9)
Concrete Modulus of Elasticity (Ec) = 2.7E+04 MPa (Clause 8.5.1)
n (Es/Ec) = 7.41 (Clause 8.5.2)
Section Properties
Thickness of Section (t) = 30.00 cm Depth of Ten. Reinforcement (d) = 27.00 cm
Breadth of Wib (bw) = 100.00 cm Depth of Comp. Reinforcement (d') = 3.00 cm
Breadth of Flange (bf) = 100.00 cm Flange Thickness (tf) = 30.00 cm
Tension Reinforcement (As) = 36.00 cm2 Compression Reinforcement (As') = 14.00 cm2
Span (l) = 8.50 m
Nutral Axis Depth (z) = 9.17 cm
Gross Moment of Inertia (Ig) = 225000.00 cm4 = 2.25E+09 mm4
Cracked Moment of Inertial (Icr) = 113895.62 cm4 = 1.14E+09 mm4
Cracking Moment (Mcr) = 6.03E+07 N mm = 6.03 m. t (Eq. 9-8)
Service Straining Actions
Bending Moment Due to Dead Load only (Md) = 5.50 m.t = 5.5E+07 N. mm
Bending Moment Due to Live Load only (Ml) = 2.00 m.t = 2.0E+07 N. mm
% of Sustained Load from the Live Load = 30%
% of Gross Inertia Used in Calculation = 100%
Bending Moment Due to Sustained Load (Msus) = 6.1 m.t = 6.1E+07 N. mm
Calculated Short Time Deflection (Calculated by total or percentage of gross moment of inertia)
Deflection due to Dead Load (Di)d = 0.6200 cm = 6.200 mm
Deflection due to Live Load (Di)l = 0.2000 cm = 2.000 mm
Efffective Moment of Inertia (Eq. 9-7)
Under Dead Load Only (Ie)d = 225000.00 cm4 = 2.25E+09 mm4
Under Sustained Load (Ie)sus = 221314.47 cm4 = 2.21E+09 mm4
Under Dead + Live Load (Ie)d+l = 171690.078 cm4 = 1.72E+09 mm4
Modified Short time Deflection
Deflection due to Dead Load (Di)d = 0.6200 cm
Deflection due to Sustained Load (Di)sus = 0.6913 cm
Deflection due to Dead + Live Load (Di)d+l = 1.0746 cm
Deflection due to Live Load (Di)l = 0.4546 cm
Additional Long Term Deflection (Clause 9.5.2.5)
For 5 years or more (Dlong) = 1.09799 cm For 12 months (D long
) = 0.76859 cm
For 6 months (Dlong) = 0.65879 cm For 3 months (Dlong) = 0.54899 cm

Results
-- Flat roofs not supporting and not attached to nonstructural elements likely to be damaged by large defelections:
(Di)l = 0.4546 cm < l/180 = 4.7222 cm
-- Floors not supporting and not attached to nonstructural elements likely to be damaged by large deflections:
(Di)l = 0.4546 cm < l/360 = 2.3611 cm
-- Roof or floor construction supporting or attached to nonstructural elements likely to be damaged by
large deflections:
(Dlong) + (Di)l = 1.5526 cm < l/480 = 1.77083 cm

367505400.xls - Rev. 0 T - Section


-- Roof or floor construction supporting or attached to nonstructural elements not likely to be damaged by
large deflections:
(Dlong) + (Di)l = 1.5526 cm < l/240 = 3.5417 cm

367505400.xls - Rev. 0 T - Section

You might also like