D=360 TN

L=72 TN

ntn
L=3.40m
H= 80cm

adm= 4 kg/cm2
adm neto = 3.808 kg/cm2 L=3.40m

DISEAR LA ZAPATA AISLADA Vista en planta


Columna= 0.60x0.60
Fc= 210 kg/cm2
Fy= 4200 kg/cm2

PASO 1. Hallar area de Zapata

Capacidad portante neto

Asumir H= 80 cm

Peso de zapata = (2400 kg/m3)x0.80m=1920kg/m2 = 0.192 kg/cm2

Capacidad portante neto = 4-0.192 = 3.808 kg/cm2



=

Nota: el peso se considera sin factorar cargas

(360 000 + 72 000)


= = 113 445.38 2

.

L x L = 336.82 cm X 336.82 cm

L x L = 3.40 m X 3,40 m
Paso 2. Calculo cortante normal

qu = (1.2x360)+(1.6x72)= 547.2tn / 3.40x3.40 = 47.33 tn/m2

qu = 47.33 tn/m2

d= 70cm H= 80cm

d=70cm

qu = 47.33 tn/m2

L1=3.40 3.40

Vu

L2=3.40
L1=3.40
0.80
L=1.40
0.70
(L d)
= 1 ( ) = (47.33tn/m2)(3.40m)(0.70m)= 112.67 tn

= = 112.67 tn / 0.75 = 150.23 tn, Cortante actuante

= 0.53 = 0.53210/2 340 70 = 182.79 ,


cortante permisible
(182.79) > (150.23) .

Paso 3. Verificacin por punzonamiento

L=1.30
Apz

L1=3.40 L=1.30
0.60
0.35
0.35
Atz
d/2

L2=3.40

= ( )( ) = (47.33 tn/m2)(3.4x3.4 1.30x1.30) = 467.15 tn

=467.15/0.75= 622.87 tn 623 tn

= 1.06 (verificacin por punzonamiento)


= permetro del punzonamiento

= . / () = 559.14tn lo que soporta

Actuante soporta
623 tn > 559 tn ..zapata se punzona

Entonces se cambia el peralte


H=90
= ( )( ) = (47.33 tn/m2)(3.4x3.4 1.40x1.40) = 454.37 tn
=454.37/0.75= 605.83 tn 606 tn
= . / () = 688.17

Actuante soporta
606 tn < 688 tn ..OK

Paso 4 : diseo de acero

You might also like