You are on page 1of 4

Color Fastness to Wash (ISO 105 C06)

Color Fastness to Washing:


Color fatness to washing means, A specimen of the textile, in contact with one or
two specified adjacent fabrics, is mechanically agitated under described conditions
of time and temperature in a soap solution, then rinsed and dried. The change in
color of the specimen and the staining of the adjacent fabric are assessed with the
grey scales.

In my personal experience, in case of fastness test color fastness to washing is


the first and most important requirements of buyers. There are a number of ISO
test for color fastness to washing.

Washed sample
These are :
1. ISO test no-1
2. ISO test no-2
3. ISO test no-3
4. ISO test no-4
5. ISO test no-5
6. ISO 105 C06

ISO 105 C06 A2S


ISO 105 C06 B2S
ISO 105 C06 C2S

Among them ISO 105 C06 is the first choice of maximum buyers.
Now I will discuss about those fastness test.
Multi fiber fabric
ISO 105 C06:
Instruments:

1. Rotawash / Gyrowash,
2. Stainless Still Ball,
3. Multi-fiber fabric,
4. Grey scale,
5. Sewing machine,
6. Thermometer,
7. Color matching cabinet

Recipe:
Sodium Perborate..1 gm/litre
ECE Phosphate..4 gm/litre

Sample Preparation:
Sample Fabric.10 cm*4 cm
Multi fiber fabric10 cm*4 cm
Working Procedure:
Collecting the sample from bulk and then conditioning for 04.30 to 06 hours

Making a specimen of 04 cm*10 cm in size.

Sewing the specimen with multi-fibre fabric of same size at one corner.

Making the solution of 4gm/litre ECE detergent & 1 gm/litre sodium perborate, (If
required SKFL use 0.15 gm/litre TAED).

Putting the specimen with multi-fibre fabric into the solution in Rotawash m/c
Prog.: C2S Temp.: 60OC/ 40OC Time: 30 min Still ball: 25 pcs

Rinsing with hot water respectively.

Squeezing with cold water of the sample is done (Hand Wash).

Then drying is done at a temperature in the air not exceeding 60OC

The stitching is then broken out except on one of the shorter end.

Measuring the staining and color change by grey scale & make a test report.

For ISO 105 C06 A2S:

1. Total solution (changeable) 150 ml


2. Stainless Still Ball..10 (for hitting)
3. Time40 min
4. Temperature400C

Everything is same.

For ISO 105 C06 B2S:

1. Total solution (changeable) 150 ml


2. Stainless Still Ball..25 (for hitting)
3. Time40 min
4. Temperature500C

Everything is same.
For ISO 105 C06 C2S:

1. Total solution (changeable) 50 ml


2. Stainless Still Ball..25 (for hitting)
3. Time40 min
4. Temperature600C

Everything is same.