INGENIERIA SANITARIA

CAPITULO Alcantarillado
CALCULO Indice de Pomeroy
ELABORADO Barboza Diaz Miguel
FECHA 13 de Julio del 2016
CALCULO DE INDICE DE POMEROY

CRITERIOS DE DISEO

Qi= 1.5 Qf= 2.2 DBO5= 2.5mg/l

T= 24C S= 5%o n= 0.013

= 1009 kg/m3

1.- Asumieros un DN: 200mm

2.-Calculo de Qo

=(0.312 0.2 ^(8/3)


0.005 ^(1/2))/0.013

Qo = 0.0232 m3/s

3.-Calculo de Vo:

V=(0.397 0.2 ^(
2/3) 0.005 ^(1/2
))/0.013
V=(0.397 0.2 ^( =
2/3) 0.005 ^(1/2
))/0.013
VO = 0.73850 m/s

qi/Qo= 1.8/23.2= 0.0776

Segn tabla:
Y/D= 0.1876
V/Vo= 0.5952

4.-Calculo de Velocidad

Vi= V/vo * Vo = 0.7385*0.5952 =


Vi = 0.4396 m/s

5.-Calculo de Radio Hidraulico (Rh)

Rh = 0.0230 m

0.2m
0.077

0.023

H = 0.128m

P= *r 0.1384 m

= 2(arcCos(0.077/0.1)
= 79.29 = 1.3839 rad
6.-Ahora Calculo de La Tension tractiva

i = 9.81*1009*0.005*0.023
i = 1.14 Pa OK , CUMPLE!

7.-Calculo de Z

z= 1142.90