Give them the additional strength of

Recron 3s secondary reinforcement.


Concrete is widely used because of its valuable properties. It has high compressive strength and stiffness, HOW RECRON 3S WORKS:
low thermal and electrical conductivity, besides being non-combustible and non-toxic.
Improves resistance to plastic & drying shrinkage/cracking
While these advantages are enough for many purposes, ordinary concrete falls short when used in certain
Inhibits propagation of micro-cracks and provides stability to concrete
construction projects. Faced with repeated stress, temperature variations and corrosion, it tends to
become brittle, lacking tension and developing cracks. Given that most of these projects are of vital Improves flexural toughness/increases split tensile strength

infrastructural importance, ordinary concrete will obviously not do. Enhances abrasion resistance and increases energy absorption of concrete,
thereby improving impact resistance
Thats when Recron 3s can add muscle to concrete. A specialty secondary reinforcement additive,
Recron 3s adds toughness and tensile strength to concrete, while helping resist shrinkage and cracking. It Aids in making concrete more homogenous

also bonds better with the mix, thanks to a unique triangular cross section and dimensional stability. Reduces permeability in concrete

Developed after extensive research at the Reliance Technology Centre, Recron 3s has been widely used in Improves durability and enhances the longevity of the structure

a variety of applications. You can be sure that it will add value to the special structures you build.
APPLICATION AREAS
Fibre length & dosage (kg/cum)
APPLICATION 6 mm 12 mm 18 mm
Sub Application

RCC Slab-Normal/PSC 0.6-0.9 0.6-0.9


Beams/Columns 0.6-1.2
Deck Slab 0.9-1.5 0.9

SLAB ON GRADE Floorings 0.9 0.9-3.0


Parking lots 0.9 0.9-2.0
Ramps 0.9 0.9-3.0

WATER RETAINING STRUCTURES Concrete 0.9-2.0


Canal Linings 0.9-1.5
Drains 0.9
Tanks 0.9-1.2
Cooling Towers 0.9-1.2

PAVEMENTS PQC 0.9-3.0 0.9-3.0


Toppings/Overlays 0.9-3.0 0.9-3.0
Parallel Taxi Track 0.9-3.0 0.9-3.0
Runways 0.9-3.0 0.9-3.0
Parking Bays 0.9-3.0 0.9-3.0

SCREEDS/MORTARS Plaster 0.6-0.9


Screed 0.6-0.9 0.6-0.9
Mortar 0.6-0.9

Recron 3s has Unique Triangular Cross-Section which gives 40% more SHOTCRETE Crown 0.9-1.5 0.9-1.5
surface area for bonding compared to other shapes. Walls 0.9 0.9
Rehabilitation 0.9-1.5 0.9-1.5

Recron 3s is also designed so that PRECAST Partition Walls 0.6-0.9 0.9-2.0


the fibre stays dimensionally straight Slabs 0.9
d Manhole Covers 0.9-3.0
and uniformly dispersed, so as to
safeguard against balling, curling and Pavers/Tiles 0.6-0.9 0.6-0.9
Thin Sections 0.6-0.9 0.6-0.9
bunching.
a = 1.35d PRE MIX MORTARS 0.9-1.5
160
140

Average Crack Area, mm2


120 0.08%
100
0.16% Fibre A - 18 mm Length
80
0.08%
Fibre B - 12 mm Length
60
0.16%
Fibre C - 6 mm Length
40
20 0.08%
0.16%
0

Fibre A Fibre B Fibre C

1.6
SR. NO. PROPERTIES GAIN OVER NORMAL MIX TESTED BY
1.4
1 Compressive Strength +12 to 16% CBRI Roorkee
(28 days) (Incremental gain noticed IIT Madras IPRI Punjab 1.2
in select grades) CRRI - New Delhi 1

ARS, MPa
Al Futtaim Bodycote Dubai
0.8

2 Flexural Strength +7 to 20% CBRI Roorkee Civil-Aid-BLore 0.6


CRRI - New Delhi IPRI Punjab 0.4
Al Futtaim Bodycote Dubai
0.2
3 Split Tensile Strength +7 to 22% CBRI Roorkee Civil-Aid-BLore 0
SVNIT Surat IPRI Punjab Plain 0.3% 0.5% 0.75%
GERI Baroda KCT Coimbatore Concrete Fibre A Fibre A Fibre A
3 Fibre Volume Fraction
4 Drying Shrinkage -48 to -80% CRRI - New Delhi IIT Madras
UBC Canada Civil-Aid-BLore 2.5
0.08%

Max Crack Width, mm


5 Water Percolation -44 to -60% CRRI - New Delhi
2 0.16%
Al Futtaim Bodycote Dubai

6 Permeability, K cm/sec Reduced to nil with IPRI Punjab IIT Madras


1.5
0.16%
under stressed conditions fibre Reinforced Civil-Aid-BLore 0.08%
1 0.16%
Concrete under
5 bar pressure
0.5 0.08%
7 Abrasion Resistance +25% CRRI IIT Madras
8 Impact Resistance +40 to 140% IIT Roorkee IPRI Punjab 0
9 Damping of Material 26% SVNIT Surat Fibre A Fibre B Fibre C
(under dynamic loading)
80
10 Energy Absorption 55% SVNIT Surat
11 Young's Modulus 23.70% SVNIT Surat 70
12 Fatigue Life (cycle) + 230% M.S. University, Baroda 60
These figures are the result of rigorous testing by
13 ARS (Average Residual 2-15 times of UBC Canada
renowned national and international laboratories, 50

R 600 100 (%)


Strength) of FRC Plain Concrete
including IIT Madras, IIT Roorkee, CRRI Delhi, 40
14 Toughness 6-12 times of UBC Canada
CBRI Roorkee, IPRI Punjab, SVNIT Surat, Baroda
Plain Concrete 30
University, Civil Aid Bangalore, BFRC Bangalore,
20
Al Futtaim Bodycote Dubai and the University of
British Columbia, Canada. 10
0
Plain 0.3% 0.5% 0.75%
Concrete Fibre A Fibre A Fibre A
Fibre Volume Fraction
PRODUCT TYPE LENGTH POUCH SIZE
POLYESTER
CT2012 6mm 125g
CT2024 12mm 125g
CT2436B/CT2436 18mm 450/900g
CT2424B/CT2424 12mm 450/900g

POLYPROPYLENE
CTP2012 6mm 90g
CTP2024 12mm 125g
CTP2424B 12mm 450g
CTP2436B 18mm 450g
Recron 3s has been adopted by construction industry across India, who have come to rely on its supe-
rior bonding and strengthening qualities. Here are a few figures:
Added to over 15 million cu. m. of concrete and 25 million square feet of plaster in India
Used and accepted by Indias top 100 realty companies
Adopted by over 60 precast manufacturers

Experience speaks with:

* 5 million cu. m. of concrete in Roads & Pavements * 1 million cu. m. of concrete in Flooring/Hardstandings
* 3 million cu. m. concrete in Housing-Residential sector * 3 million cu. m. concrete in Industrial sector
* 1 million cu. m. of concrete in Water Retaining Structures including Canal Linings
* Special Applications Undersea - Altitude above 3000 m & special thin sections precast
Make Recron 3s work for you.
CONTACT
Head Office and Export Division, Navi Mumbai
Tel: +91 22 44781335 Fax: +91 22 44 779107. Email: recron3s@ril.com

Western Region Southern Region


Mumbai - Regional Office Coimbatore - Regional Office
Tel.: (022) 44780153/44780151 Tel.: (0422) 4291100
Fax: (022) 40614890 Email: ganesh.nk@ril.com
Email: vinesh.singhvi@ril.com Bangalore - Tel.: (080) 41470088
Ahmedabad - Tel.: (079) 40212212/40212121 Fax: (080) 41499881
Fax: (079) 40021242 Email: vandana.iyengar@ril.com
Email: siraz.mohamadi@ril.com Chennai - Tel.: (044) 43320300
Fax: (044) 43320305/6
Email: rajagopalan.narayan@ril.com

Northern Region Eastern Region


Ludhiana - Regional Office Hyderabad - Regional Office
Tel.: (0161) 4633610 Tel.: (040) 40031355
Fax: (040) 40031255
Delhi - Tel.: (011) 40658044/40658048 Email: shrirangramrao.tembe@ril.com
Fax: (011) 40658046 Kolkata - Tel.: (033) 40013466
Email: rajiv.gauri@ril.com, Fax: (033) 40013465
manish.r.tiwari@ril.com Email: raghunath.mukherjee@ril.com

Reliance Corporate Park, Bldg. No. 8, B-Wing, 1st Floor, Thane-Belapur Road, Ghansoli, Navi Mumbai-400701, India.
Visit: www.ril.com

The information in this brochure is believed to be accurate. Performance data was obtained in a specific environment and also is believed to be accurate and reliable. Reliance Industries Limited does not warrant the properties or performance of Recron 3s