You are on page 1of 12

Short

Parameter Range Vendor Recommended


Description

dlCodeAdm 0 to 100 80
pwrAdm 0 to 100 75
maximumTransmissionPower 0 to 500 N/A
sf8Adm 0 to 8 8
dlHwAdm 0 to 100 100
ulHwAdm 0 to 100 100
qOffset1sn(UtranRelation) -50 to 50 0
qOffset1sn(GsmRelation) -50 to 50 7
qOffset2sn -50 to 50 0
individualOffset(UtranCell) -10 to 10 0
individualOffset(ExternalUtranCell) -10 to 10 0
individualOffset(ExternalGsmCell) -10 to 10 0
releaseAseDlNg 0 to 500 3
releaseAseDl 0 to 500 1
nOutSyncInd 1 to 256 10
rlFailureT 0 to 255 10
dchRcLostT 0 to 100 50
hsDschRcLostT 0 to 600 50
minPwrRl -350 to 150 -150
minPwrMax -350 to 150 0
AT&T Recommended Permission Unit Resolution Node Group (MOC)

85 Fixed % Cell UtranCell


75 Fixed % Cell UtranCell
N/A Variable 0.1dBm Cell UtranCell
2 or less Variable Radio Links Cell UtranCell
100 Fixed % Node B IubLink
80 Fixed % Node B IubLink
0 Fixed dB Nabr UtranRelation
7 Fixed dB Nabr GsmRelation
-10 to 10 Variable dB Nabr UtranRelation
0 Fixed 0.5dB Cell UtranCell
0 Fixed 0.5dB Nabr ExternalUtranCell
0 Fixed 0.5dB Nabr ExternalGsmCell
3 Fixed ASE Cell UtranCell
1 Fixed ASE Cell UtranCell
10 Fixed frames Cell UtranCell
10 Fixed 0.1seconds Cell UtranCell
50 Fixed 0.1seconds RNC Rcs
100 Fixed 0.1seconds RNC Rcs
-180 Fixed 0.1dB Cell UtranCell
-15 to 30 Variable 0.1dB Cell UtranCell
Functional Category Suffix 1

Admission and Call Establishment Control


Admission and Call Establishment Control
Admission and Call Establishment Control
Admission and Call Establishment Control
Admission and Call Establishment Control
Admission and Call Establishment Control
Cell Selection and Reselection UtranRelation
Cell Selection and Reselection GsmRelation
Cell Selection and Reselection
Handover and Cell Change UtranCell
Handover and Cell Change ExternalUtranCell
Handover and Cell Change ExternalGsmCell
Congestion Detection and Resolution
Congestion Detection and Resolution
Radio Link Supervision
Radio Link Supervision
Radio Link Supervision
Radio Link Supervision
Power Control
Power Control
Date Revision Parameter
11/18/2008 4.0 N/A
12/18/2008 4.1 N/A
gsmAmountPropRepeat
gsmPropRepeatInterval
usedFreqW2d
1/20/2009 4.2
usedFreqW2f
utranW3a
minPwrMax
1/26/2009 4.3 fddIfHoSupp
Updated (hicap) parameters and values
1/27/2009
sRatSearch(hho_if)
4.4
usedFreqRelThresh4_2bEcno
2/10/2009
usedFreqRelThresh4_2bRscp
Removed values for (hicap) - maintained highlighting
pwrLoadThresholdDlSpeech.amr12200
codeLoadThresholdDlSf128
2/26/2009 4.5
aseLoadThresholdUlSpeech.amr12200
pwrLoadThresholdDlSpeech.amr7950
aseLoadThresholdUlSpeech.amr7950
3/5/2009 qRxLevMin
4.6
3/13/2009 maximumTransmissionPower
4/1/2009 4.7 maxActiveSet
4/17/2009 4.7.1 N/A
numEulResources
qRxLevMin(sho_c)
qRxLevMin(hho_if_c)
qRxLevMin(hho_if_b)
qRxLevMin(hho_ir_c)
qRxLevMin(hho_ir_b)
qQualMin(sho_c)
qQualMin(hho_ir_c)
qQualMin(hho_ir_b)
qQualMin(hho_if_c)
qQualMin(hho_if_b)
sIntraSearch(sho_c)
sIntraSearch(hho_if_c)
sIntraSearch(hho_if_b)
sIntraSearch(hho_ir_c)
sIntraSearch(hho_ir_b)
sInterSearch(sho_c)
sInterSearch(hho_if_c)
sInterSearch(hho_if_b)
sInterSearch(hho_ir_c)
5/1/2009 4.7.2 sInterSearch(hho_ir_b)
sRatSearch(hho_if_b)
sRatSearch(hho_if_c)
sRatSearch(hho_ir_c)
sRatSearch(hho_ir_b)
usedFreqThresh2dEcno(sho_c)
usedFreqThresh2dEcno(hho_ir_c)
usedFreqThresh2dEcno(hho_ir_b)
usedFreqThresh2dEcno(hho_if_c)
usedFreqThresh2dEcno(hho_if_b)
hysteresis2d
usedFreqThresh2dRscp(sho_c)
usedFreqThresh2dRscp(hho_ir_c)
usedFreqThresh2dRscp(hho_ir_b)
usedFreqThresh2dRscp(hho_if_c)
usedFreqThresh2dRscp(hho_if_b)
hoType(sho_c)
hoType(hho_if_c)
hoType(hho_if_b)
hoType(hho_ir_c)
hoType(hho_ir_b)
Original value New Value
N/A N/A
N/A N/A
4 1
5 10
10 3
10 3
10 3
0 -15 to 30
0=FALSE 1=TRUE
various various
4 0
-1 2
-3 6
N/A N/A
100 50
100 0
100 0
100 0
100 0
range -115 to -25 range -119 to -25
400 N/A
3 3 or 4
N/A N/A
N/A 1=TRUE
-113 -115
N/A -115
N/A -107 4
N/A -115
N/A -107 4
-20 -24
N/A -20
N/A -20
N/A -24
N/A -24
23=12 25=16
N/A 25=16
N/A 25=16
N/A 23=12
N/A 23=12
22=10 24=14
N/A 24=14
N/A 24=14
N/A 22=10
N/A 22=10
N/A 4
N/A 4
N/A 4
N/A 6
-15 -23
N/A -15
N/A -12
N/A -15
N/A -12
4 4
-112 -115
N/A -115
N/A -106 4
N/A -115
N/A -106 4
2=NONE 2=NONE
N/A 0=IFHO_PREFERRED
N/A 0=IFHO_PREFERRED
N/A 1=GSM_PREFERRED
N/A 1=GSM_PREFERRED
FGA Reference
Originated version 4.0 for Ericsson P6
Added (hicap) to differenicate parameter reccomendations for cells used durning events that demand high
04 0-E-001 Ericsson UTRAN Field Guide Notification Alert - gsmAmountPropRepeat and gsmPropRepea
04 0-E-001 Ericsson UTRAN Field Guide Notification Alert - gsmAmountPropRepeat and gsmPropRepea
04 0-E-002 Ericsson UTRAN Field Guide Notification Alert - usedFreqW2d, usedFreqW2f and utranW3a
04 0-E-002 Ericsson UTRAN Field Guide Notification Alert - usedFreqW2d, usedFreqW2f and utranW3a
04 0-E-002 Ericsson UTRAN Field Guide Notification Alert - usedFreqW2d, usedFreqW2f and utranW3a
04 0-E-003 Ericsson UTRAN Field Guide Notification Alert - minPwrMax Parameter Change.pdf
Typographical error
Parameters were updated based upon 2009 Super Bowl game in Tampa.
Typographical error
Typographical error
Typographical error
Parameter values might not be scalable to all events. Researching.

04 0-E-004 Ericsson UTRAN Field Guide Notification Alert - Activation of AMR 5.9.pdf

Typographical error
04 0-E-006 Ericsson UTRAN Field Guide Notification Alert - Alignment of maximumTransmissionPower.pd
04 0-E-008 Ericsson UTRAN Field Guide Notification Alert - UTRAN maxActiveSet Parameter Change.pd
Spreadsheet format change for "golden parameter" project.
04 0-E-009 Ericsson UTRAN Field Guide Notification Alert - UTRAN numEulresources Parameter Change
04 0-E-010 Ericsson UTRAN Field Guide Notification Alert - Layer Management Configuration