You are on page 1of 2

Oil-filled instrument transformers

Type EMF-E 52-145 kV voltage transformer


Dependable accuracy

Inductive voltage transformer EMF-E is a single phase


design with distributed-gap low-loss core design for
stable performance. The transformer has oil insulated
shield-graded construction intended for outdoor
installations.

Features
Designed and tested in accordance with latest IEC 61869-3
Hermetically sealed with gas cushion or bellows expansion
system
Low core flux density with 190% overvoltage for 8 hours
High accuracy and thermal burden
Polymeric and porcelain insulators available

Benefits
Easy installation and commissioning
Maximum reliability and minimal maintenance
Suitable for wide range of environmental conditions, including
heavily polluted areas
Good seismic performance
Excellent application engineering support

Technical data
Type EMF-E072 EMF-E084 EMF-E123 EMF-E145
Highest voltage for equipment Um [kV] (r.m.s.) 72.5 84 126 145
Rated power-frequency withstand voltage [kV] (r.m.s.) 140 150 230 275
Rated lightning impulse withstand voltage [kV] (peak) 325 380 550 650
Rated frequency [Hz] 50 or 60Hz
Rated secondary voltage [V] 100/3; 100/3; 100; 110/3; 110/3; 110; 115/3; 115/3; 115; others on request
Voltage factor Up to 1.9x for 8 hours
Accuracy class 0,1; 0,2; 0,5; 1,0; 3,0; 3P; 6P (IEC) other standards on request
Rated thermal limiting output [VA] Up to 2000 Up to 2000 Up to 4000 Up to 4000
Standard ratings shown above. Contact ABB for any requirements not shown.
Dimensions and weights
EMF-E072 EMF-E084 EMF-E123 EMF-E145
A (A1/A2) Overall height [mm] 1580 / 1450 1925 / 1795 2144 / 1907 2354 / 2117

B Arcing distance [mm] 660 1005 1005 1215

C Height to lowest ungrounded part [mm] 491 491 602 602

D Front-view dimension [mm] 535 535 693 693

E Side-view dimension [mm] 618 618 691 691

F (F1/F2) Expansion systemdiameter [mm] 350 / 450 350 / 450 416 / 450 416 / 450

G Mounting dimensions [mm] 310-350 x 310-350 310-350 x 310-350 410-450 x 410-450 410-450 x 410-450

2129PL1462-w1-en Edition 11.2016


H (H1/H2) Height to primary terminal [mm] 1580 / 1239 1925 / 1584 2144 / 1695 2354 / 1905

Creepage distance [mm] 1813 3075 3075 3650

Weight [kg] 185 210 300 315

Oil volume [kg] 35 40 60 62


All above information is based on porcelain insulator 25mm/kV creepage distance and it is identical for both expansion systems, with exception of A1; F1; H1 for gas cushion
expansion tank and A2; F2; H2 for bellows.

F1

F2
A1/H1

A2

G
H2

G
4x 30
C

D E

For more information please contact: We reserve the right to make technical changes or modify the contents of this
document without prior notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any responsibility whatsoever for
www.abb.com/highvoltage potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations
contained therein. Any reproduction, disclosure to third parties or utilization of its
contents in whole or in parts is forbidden without prior written consent of ABB.

Copyright 2016 ABB


All rights reserved

You might also like