Project No 7269D

Beijing E Solvent Technologies Corp.


Project of 100.000 Ton/Year of Asphalt Unit No 201
Luoyang Petrochemical 400.000 of Oil-Sand
Engineering Design co.,
LTD Separator Device Page 1 of 2

1. Location Number M-20103AB


The whole content of this document is under the copyrights of LPDC. The confidential technical information can only be used by the person who needs the information in your department. Any reproduction, transfer, alteration or utilization of the document without prior written consent of LPDC is prohibited.

2. Device Name Dry Mixer


3. Quantity 2 Units

4. Unit Description
This device shall include all necessary equipment,regulating valve and instrument.

5. Proceed Requirements
5.1 Operational Parameters
Annual Operating Capacity 8000h
Material handling Oil, Sand and Water
Flow 55t/h
Solvent Injection Quantity 13.75t/h
Mixed Volume 55m3/h
Operational Temperature 40
Operational Pressure Normal
Mixing Period 5min
Feeding duration 30s
Discharge duration 30s
5.2 Mineral Specification
Particle Size 10mm
Density of Mixed materials 1540kg/m3
Viscocity of Mixed materials 1700pas

5.3 Structure Material


Will be specified by manufacturer

5.4 Operating Flexibility of Device

The highest flow of device is 70t/h

6. Performance Requirements of Dry Mixer Machine


a. Any volatile and imflammable solvent, require full-seal equipment;
b. Installation solvent spray device;
c. Exhaust vent and sampling port;
d. Automatic control for feed and discharge control valve;

R
Disclaimer:

e 3
v
i 2
Checked by Checked by Approved by Date
s 1
i
o
###

0
n
Project No 7269D
Beijing E Solvent Technologies Corp.
Project of 100.000 Ton/Year of Asphalt Unit No 201
Luoyang Petrochemical 400.000 of Oil-Sand
Engineering Design co.,
LTD Separator Device Page 2 of 2
The whole content of this document is under the copyrights of LPDC. The confidential technical information can only be used by the person who needs the information in your department. Any reproduction, transfer, alteration or utilization of the document without prior written consent of LPDC is prohibited.

7. Utilities

7.1 Circulation Water


TemperatureInlet/Outlet - C 32 / 40
PressureInlet/Outlet - MPag 0.4/0.2
7.2 Electricity
- Over 0.2 KW Current 380 V, 3 Phase, 50 Hz
Single
- Below 0.2 KW Current 220 V, 50 Hz
Phase,

7.3 Steam
- Temperature - C 190
- Pressure - MPag 1

7.4 Nitrogen
- Temperature - C 40
- Pressure - MPag 0.8

7.5 Purified air


- Temperature - C 40
- Pressure - MPag 0.8

7.6 Non-purified air


- Temperature - C 40
- Pressure - MPag 0.8

7.7 Softened Water


- Temperature - C 40
- Pressure - MPag 0.4

R
Disclaimer:

e 3
v
i 2
Checked by Checked by Approved by Date
s 1
i
o
###

0
n