TABLE OF CONTENTS
Grouts9
VM1 Grout 13
SV 1 Quick-Setting-Grout 14
UM1 Tamper Grout 16
VM 100 Grout 17
Repairing Grout18
EA 42.5 Screed & Levelling Grout 22
RE 1 Repairing & Screed PCC Grout 23
SRM Quick Repair Grout 24
FM1 Jointing Mortar 25
BS 12 Concrete Filler 26
BM1 Blitz Grout 27
SMM 13 Quick Assembling Grout 28
MM1 Bricklayer Grout 29
AI 1 F Anchor Bolt /Injection 30
HK1 Etching Primer 31
FE 1 Floor Screed 33
Paving & Joint Grouts 35
Floors37
P 22 ARMOURED Floor 38
Flumy 2000 40
Epoxy Resins41
EH / Crack 42
Polyurethane & Acrylate46
MAC 1 Methacrylate 50
Fire Protection Class - Info 52
PRODUCT INFORMATION
Dear customer,
we thank you for your interest in our products and we hereby deliver you a
compilation of our product informations.
In particular, we would like to draw your attention to our grouts, with which we are
worldwide market leaders and, due to the high quality, have delivered the basis of the
DAfStb guidelines.
Reg . 2 ) Catalog
The high final pressure and flexural strength of 134.7 / 14.7 N / mm are of
particular interest. The values of 89.2 / 11.5 N / mm allow a 100% load after
already 24 hours.
PRODUCT INFORMATION
Here, we refer to the particular extraction data on page 13. Every 25mm
Steel rod was set in concrete just 15 centimeters deep and pulled in a tensile test
after only 24 hours. With the level of performance we are on top of the world
rankings.
Even old certificates, see the historical part from 1970, have almost the same values,
although two cement standards changes were operated in this period of time.
VM100, latest development of the grout pressure strength after 24 hours of 106.5
N / mm. In addition to the even expansion, the shrinkage was measured with the
lowest score worldwide: 0.09 mm / m after 90 days. These are 900% less than the
required setpoint.
EU Declaration of Conformity
EU Declaration of Conformity
PRODUCT INFORMATION
EU Declaration of Conformity
Initially, a number of studies have been made for companies such as MAN, Sulzer AG,
BBC turbines and the most interesting one for Siemens AG.
Siemens asked for a certificate that would ducument the behavior of grout under
pressure and vibrations. Usually mortars are destroyed under these conditions.
The VM1 GROUTING MORTAR (former name V1 grouting mortar) improved under
pressure and vibration compressive strength due to internal compression.
PRODUCT INFORMATION
The NOVO 2012 VM GROUTING MORTAR is the first product of grouting mortar,
which combines the perfect properties of cement and epoxy resin; Slump-flow 124
cm , compression strength 130 N / mm.
EU Declaration of Conformity
INFORMATION
For one, it is highly fluid, almost like water - or rather like a thin fine pulp of
semolina pudding. Such efficient diffusion is required to fill all voids and to ensure the
area-wide, even distribution of the grout.
A critical quality is that the VM1 GROUT does not shrink and, in fact, expands by
0.5%, thus ensuring optimal transmission of power. It achieves an average compressive
strength of about 134 N/mm!
These special properties have advanced the VM1 GROUT to a benchmark industrial
product, with various applications, such as the grouting of machinery, anchors,
bridges, columns, crane track machines and turbines.
We can also offer you the VM1 GROUT reinforced with steel fibers as a solution to
structural problems in inaccessible areas.
HISTORY
The company Arnfried Pagel pers. Ing. GmbH & Co. KG was founded on May 12th,
1961 in Essen - Kettwig after a previous 1.5-year phase of product development.
1971 Mr. Pagel added a research laboratory for concrete and plastics.
From the onset, developing grouts (e.g. V 1, VM 100) was Mr. Pagels priority,
not only in our own laboratory and in terms of international sales, but especially
because of its high quality - topping the world rankings. This position was expanded
and consolidated to this day.
Our business partners are large-scale industries, big contractors, construction and
civil engineering companies in general, up to the large spectrum of users such as
track builders, turbine and windmill manufacturers, but also installation companies
and plumbers.
Grout
force transmitting non shrink cement bound
Grouts
PROPERTIES AREAS OF
APPLICATION
IM 0 Injektions-Cement-Suspension
grain size: 0; high flowable, filling and glueing and For mining and tunneling and
force transmitting by high penetration and frictional pre-stressed channel,
IM 0 cavities, cracks and gaps
bound.
cement based, low viscosity, structurefilling soil hardening,
pumpable-, pourable and vapour permeable. tube drainages,
frictions,
IM 00 Injection-Micro-Cement-Suspension reactor constructions
IM 00 same areas of application , as IM 0
Grain size: 0,015; high flowability,
low viscosity: natural protection against corrosion
10
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
Specifications
extansion % kg
per l
106,9 108,3 113,7 119,5 129,5 135,1 15,6 16,9 18,3 21,2 21,2 23,1 21,0 27,8 0,1 2,0
58,5 70,5 84,3 99,8 100,3 106,9 6,6 11,2 12,5 13,5 13,4 13,5 21,3 26,2 0,6 1,8
66,1 76,5 84,7 98,0 101,0 107,0 6,9 11,4 12,2 13,4 13,5 13,6 20,0 27,1 0,5 1,9
87,6 98,1 102,4 107,8 110,1 118,6 6,3 11,4 12,5 13,3 13,5 13,5 21,8 26,9 0,6 2,0
67,1 77,5 91,6 100,9 105,3 108,4 6,2 11,2 12,2 13,2 13,3 13,5 21,9 27,8 0,6 2,0
67,9 78,5 93,6 100,2 104,0 110,2 6,1 11,2 12,1 13,1 13,3 13,5 22,1 28,2 0,5 2,0
minutes minutes minutes minutes
15 30 45 60 120 360 15 30 45 60 120 360 45 120 30
2,4 9,7 11,8 14 17,1 35,8 0,7 2,0 2,7 3,2 3,6 5,1 3,0 4,1 0,6 1,6
58,5 80,0 96,2 100,4 106,8 113,2 10,3 13,2 13,6 14,1 13,9 14,0 20,2 26,1 0,5 1,9
57,5 77,5 91,6 101,4 105,2 111,2 10,1 13,2 13,5 13,7 13,9 14,1 21,0 27,2 0,5 2,1
53,5 73,5 87,6 99,4 102,0 106,2 9,9 11,2 13,6 14,0 14,0 14,1 20,0 23,0 0,6 2,2
21,0 60,0 83,2 88,1 93,2 101,2 5,0 11,2 11,8 12,1 12,3 12,5 20,3 26,1 0,7 1,8
60,5 85,5 91,6 106,4 117,6 127,2 7,7 12,2 13,9 14,4 14,4 14,5 23,2 29,1 0,6 5,5
54,2 70,5 84,6 90,3 97,4 105,4 7,8 11,2 12,1 12,2 12,3 12,5 18,2 22,1 0,6 1,8
52,8 71,5 86,4 90,4 96,1 102,5 7,5 11,6 11,6 12,1 12,4 12,8 17,4 21,2 0,6 2,0
11
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
EXAMPLES OF USE
Ventilation
funnel or
pump
Ventilation
300
P1 P2
Stabstahl
Stabstahl
28 Days
25 mm
25 mm
1 Tag
pull-out-test
7cm
Traction on
Steel bars
13 cm
steel bars
VM1
Beton B45
15 cm
VM1 Grout
non shrink - force transmitting - chloride free - cement based
GRAIN SIZE 0 - 4 mm
VM1 GROUT is a non shrinking grout for anchors,aggregates and machinery, cement-based
and free of aluminous cement.
VM1 GROUT has a flowable consistency and and an excellent void filling action, is force
transmitting on its whole surface and insentitive to pressure, shock and vibration; there
will be no decomposition, the material is resistant to cracking: W/C-ratio 0,31.5.
VM1 GROUT is consistent and almost impermeable for oil, gas and water, and also
resistant to frost and corrosive salt.
Expansion: 0.5%
Adhesive strength: 335 KN after 24 days
VM1 GROUT is cement-bound and ready for use, workable for approx. 120 minutes
25 kg of VM 1 grout, yields approximately 12,5 l of wet grout.
SV 1 Quick-Setting-Grout
non shrink - force transmitting - choride free
SV1 QUICK-SETTING-GROUT is consistent and almost impermeable for oil, gas and water,
and also resisting to frost and corrosive salt.
Expansion: 0.5%
Adhesive strength: 335 KN after 24 days
PROCESSING:
SV 1 QUICK-SETTING GROUT - ready to use - Grain size 0 - 4 mm
1 kg ready to use SV 1 QUICK-SETTING GROUT yields approx 0,5 l wet grout. The
quantity of water necessary is approximately 12%.
The bulk weight of the wet SV 1 QUICK-SETTING GROUT is approximately 2,2 to/m.
To prepare a grout of flowable consistency 3,1 liters per 25 kg bag have to be used.
The grout is workable for 8 min.
AREAS OF APPLICATION
grouting of: anchor bolts, aggregates, columns, bridge bearings, fixatores, crain rails,
machine constructions, engines, sole plates, steel constructions, turbines, vibration and
pressure parts, windmills.
UM 1 TAMPER GROUT is a non shrinking mortar or backfilling steel and concrete constructions,
cavities and anchorings.
UM 1 TAMPER GROUT is needed for non shrinking and crack free grouting of masonry. It de-
velopes a controlled expansion and guarantees a force transmitting bound between building parts
and ground work.
UM 1 TAMPER GROUT distiguishes by a high early and final strength, and is resisting to water,
frost and corrosive salt and almost impermeable for oil.
UM 1 TAMPER GROUT is load bearable just after 60 min, depending on the amount of BM 1
BLITZ-MRTEL.
SPECIFICATIONS
VM 100 Grout
non shrink - force transmitting - chloride free - cement bound
VM 100 GROUT is a non shrinking mortar for anchors, aggregates und machinery, compo-
sed of pure cement basis and free of aluminous cement.
VM 100 GROUT is consistent and almost impermeable for oil, gas and water, and also
resistant to frost and corrosive salt.
Expansion: 0.5%
Adhesive strength: 335 KN after 24 days
Steel bar 25mm Grout depth 7/15 cm Rupture load 335 KN after 24 hours DEMOLITION
Tested according to DIN 1164, controlled external and internal ,DVB intructions for grout
VM 100 GROUT is cement bound and ready for use, workable for approx. 120 minutes.
XS 3, XF 4, XA 3 and XM 3.
Repairing Grout
Renovation system
Restoration Systems
Products DAMAGES DAMAGE REPAIR
EH 1 Etching Primer Advanced or severe damage Chip off lose parts with light sledge hammer,
EHM 1 Epoxy Resin Grout with corrosed concrete steel. expose cavities,carve out the healthy core
0,1-16 mm of concrete and reinforcing concrete.
or sand blast concrete steel, open cracks with
HK 1 Etching Primer Heavy damages, disc, clean surface.
RE 16 Repair Grotl coroding reinforceing concrete,
(PCC) 0,1-16 mm carbonating, oil penetration, Let soak in EH 1 Primer untill it is sticky,
(evtl.shot crete) spallings and weatherngs, than apply EHM 1 Epoxi Resin 0,1-16 mm.
OFS 1 Surface Protection frost and de-icing salt damages, Brush in HK 1 Etching Primer, apply fresh
Corrosion protection: agressive environment damages, on fresh RE 16 -Repair Mrtel (PCC)
HK 1 Etching Primer and fire. 0,1-16 mm , apply OFS 1
EH 1 Primer. surface protection.
19
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
Specifications
Comp. Strength Bend. Strength. Ad.St. kg/ H2O
Product l
24 h 28 T. 24 h 28 T. 28 T.
Bruch
EH 1 Epoxy-Resin (also Primer) 2 Komp. 51 84 16 22 im Beton
1
Bruch
EHM 0,5 Epoxy Resin Mortar 2 Komp. 52 86 14 21 im Beton
2
Bruch
EHM 3 Epoxidharz-Grout 2 Komp. 53 87 14 22 im Beton 2
BS 0 Screed Grain Size 0 mm 21 63 7 12 18 2 0,20
BS 0,5 Screed Grain Size 0,1-0,5 mm 21 64 6 13 18 2 0,20
BS 1 Screed Grain Size 0,1-1,0 mm 22 64 7 13 17 2 0,20
BS 12 Craose Grain Size 0,1-5 mm 24 68 7 14 18 2 0,20
RM 2 Repairing-Grout (PCC) Krn. 0,1-0,2 mm 29 67 6 12 7 2 0,25
RE 5 Repairing-Grout Grain Size 0,1-5 mm 29 67 6 13 7 2 0,25
RE 8 Repairing-Grout Grain Size 0,1-8 mm 31 69 7 13 8 2 0,25
RE 12 Repairing-Grout Grain Size 0,1-12 mm 43 78 8 13 8 2 0,25
RE 16 Repairing-Grout Grain Size 0,1-16 mm 38 76 8 14 8 2 0,25
SPB 1 Shotcreed Grain Size 0-1 mm 23 33 5 9 6 2 0,20
SPB 3 Shotcreed Grain Size 0,1-3 mm 28 55 5 9 6 2 0,20
SPB 5 Shotcreed Grain Size 0,1-5 mm 29 55 5 9 6 2 0,20
UVM 3 Universal-Grout Grain Size 0,1-3 mm 52 84 8 12 21 2 0,20
UVM 5 Universal-Grout Grain Size 0,1-5 mm 53 85 8 12 22 2 0,20
UVM 8 Universal-Grout Grain Size 0,1-8 mm 56 88 9 12 22 2 0,20
UVM 12 Universal-Grout Grain Size 0,1-12 mm 57 89 9 13 22 2 0,20
UVM 16 Universal-Grout Grain Size 0,1-16 mm 60 91 11 12 23 2 0,20
UVM 22 Universal-Grout Grain Size 0,1-22 mm 63 93 12 13 23 2 0,20
VM 1 Verguss-Grout Grain Size 0-3 mm 74 101 10 13,5 27,8 2 0,20
EK 1 Elementen-Kleber 22 65 4,3 12 11,7 1,8 0,25
15 Minuten 1 Tag 15 Minuten 1 Tag
BM 1 Blitz-Grout 0-25 mm 6 20 3 6 7 1,8 0,25
RVM 1 Tube-Grout Krn. 0,1-22 mm 8 42 3 8 11 2 0,20
WST 1 Water-Stop in 5 Sec non shrinking , self setting 1,6 0,00
HK 1 Etching Primer 60% plastic, sehr stark haftend 18 1,6 0,25
MHG 1 Metal-Etching Primer 60% plastic solid surface 18 1,7 0,25
ET s Deep Impregnation 2 components , deep effect to 5 mm 24 1
VR 1 Diluter and Cleaner Impregnation helper with double feature 1
OF 1 S Surface Protection coeffizient 75 % 1
20
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
ST/VM1
2,27
2,200
7 52,2
28 71,6
After Days 12 ,6
74 ,1
28 8,2
RE 1 REPAIRING AND SCREED GROUT is stable and can also be used for overhead
works.
RE 1 REPAIRING AND SCREED GROUT has proven under extreme climatic conditions,
for construction and concrete structures, as coating and repairing of ground and wall
surfaces, bridges and tunnels, improvements of edges, cracks, stonework and butt joints,
laying tiles and slabs.
Results of perfectly processed grouts will only be as good as the thorough cleaning and
restoration of the surfaces Which they are applied to.
HK 1 ETCHING PRIMER guarantees protection and bonding of the underground of all
applied grouts.
SRM QUICK REPAIR GROUT is very sticky due its polymer component, vapor diffusible,
abrasion-resistant, frost and ice resistant, salt resistant and easy to use. All types are availa-
ble with steel fiber and/or hard surcharge compounds.
SRM QUICK REPAIR GROUT reduces CO penetration and slows down corrosion.
AREAS OF APPLICATION
Restoration, quick repairs, screeds, plaster, concrete, cracks, spallings, floors and
joints, tilings, plates and wallings, levelling, sealing by double slurries and plaster.
FM 1 JOINTING MORTAR is a specially designed finished grout, for which only water is
added for the desired consistency.
FM 1 JOINTING MORTAR can be delivered in all grain sizes, all cement types
(pozzolanic, mussel-, marble and Barrit-addings), PCC execution water proof - and deviate -
and also available in epoxy resin (resistant to fumes and chemicals) .
FM 1 JOINTING MORTAR are high quality, durable special products with strong adhesion
and wear-resistant surfaces, suitable for any joint design, also overhead as in arches.
Results of perfectly processed joints and joint sealing will only be as good as the
thorough cleaning and restoration of the surfaces Which they are applied to.
All old joints can be stabilized with FM1 JOINTING MORTAR. After this, apply a
bonding layer of HK 1 ETCHING PRIMER.
BS 12 Concrete Filler
cement bound - coated - frost, ice & salt resistant
BS 12 CONCRETE FILLER is a balanced large surface filler for walls, facades, because of
its grain size (0) seamlessly spreadable. BM 12 is abrasion resistant, breathable and sealing
(water- repellent).
BS 12 CONCRETE FILLER has a good water retention value , preventing cracks.
Processable 0-5 cm.
BS 12 CONCRETE FILLER has a high degree of admixture of synthetic materials , provi-
ding a connecting bridge. Never less a undercoating from the same material should be done,
which is practically possibly on every underground.
Fresh density < 2kg/l
BS 12 CONCRETE FILLER processable for approx. one hour, allowing large surface profiling
of plastering, joints and repairs of concrete elements. Mixing time: 3 min. 300 R/ min, temp.
4-25 C. Maturity: 3-5 min, post-blending processable: 60 min,
revisable: after max. 3 days.
BS 12 CONCRETE FILLER used with sands up to 8 mm, ratio 1:2 , can also be applied as
repair grout. Color: grey. Storable 1 year.
AREAS OF APPLICATION :
According to constructional guidelines and regulations. Repairing of cracks, porous walls und
holes, filling of frame cuts and joints, for alancing floors, facades und wall bumps. Filling of buil-
ding slabs, precast floors, aerated concrete and concrete elements, masonry and concrete, repro-
filings see information Restoration System and HK 1.
-cures in 5 min
-millisil cement bound
-grain size 0
-volume- price advantage 5 %
-can be extended 3 times
-non shrink -low in chromate
-oil resistant -chloride free
-frost resistant -watertight
-insulating -anticorrosive
-isolating
-spark-free
-fireproof (<F90)
-non-blooming -no synthetic parts
-usable indoors and outdoors -cavities-filling
-puttyable -gypsum-free
-stable -moldable, can be modulated
-spreadable to 0
-tiles , marble slabs
-high adhesion strength
-vibration resistant -product guarantee: 10 years
-storable for one year
-tested in accordance with DIN 1164
-
Expansion: 0.1%
Adhesive strength: >1,5 K/mm
SMM 13 has proven helpful for sealings, repairs of grounds, corridors and balconies, railings,
gate fixations, cantilevers, repairs, fillings, equalizations, tilings and marble slabs, tube and
shaft repairs...
technical features:
SSM 13 has a grain size of 0-0,4 mm, is anticorrosive, non shrinking, non blooming, cement
bound and storable in a closed bucket for one year, is frost and de-icing salt resistant.
SMM 13 QUICK ASSEMBLING GROUT tested according to DIN 1164, reaches high strength
in a short time. Moist the underground and brush in
SMM 13 QUICK ASSEMBLING GROUT.
TECHNICAL DATA
MM1 BRICKLAYER GROUT is a non shrinking mortar for filling and repairing concrete and
steel constructions, Zargen, windowsills, frames, etc.
MM1 BRICKLAYER GROUT is needed also for non shrinking and crack free joint-sealing.
It develops a controlled expansion and provides a rigid bond between building elements and
concrete foundation, load-bearing on the whole surface.
MM1 BRICKLAYER GROUT is distinguished by a high early and final strength, is resistant
to water, frost and corrosive salt and almost impermeable for oil.
MM1 BRICKLAYER GROUT is available in grain sizes up to 22 mm, with or without steel fiber.
TECHNICHAL DATA:
Grain Size 0 - 3 mm
Water needed: approx. 3 l - processable approx. 45 min
Even perfectly applied groutings are only as good as a thoroughly realized cleaning and
restoration of the surfaces.
AI 1 F Anchor Bolt/Injection
GRAIN SIZE 0 mm
AI 1F Anker/Injektion developes a high adhesive strength, early - and final strength (25
mm steel bars, poured 15 cm deep, tore apart after 8 days of pulling attempts).
AI 1F Anker/Injektion is suitable for drinking water areas, is water proof, anti-corrosive
and can be used for overhead works.
PROCESSING:
Before placement, the adjacent surfaces should be thoroughly cleaned and wetted.
PROCESSING:
Please read Restoration and Grouting preperation. Where existent, de-rust metallic fittings
(steel) according to DIN 55928.
Clean concrete and mortar from less sticky parts and separating substances like:
Coating rests, abrasions, impregnations, oil, fats etc. depending on necessity,
grind, mill, blast with high pressure, shot peening or sand.
After preperation, the compressive strength must be at least medium 1,5 N/mm2.
The underfloor can be slightly moist.
MIXING:
Add water - not more than 35%, mix it with mechanical agitator at max. 300 R/min thoroughly
with a compulsory mixer . Storable for one year.
Consumption per layer > 1,5 kg/m.
PROCESSING:
Diluting is not necessary.
Mix HK 1 ETCHING PRIMER to plastic-like consistence. Brush in into the pores extensively
with scrubber - Underground & Processing temperature: 4 - 50C - Mix HK 1 ETCHING
PRIMER to slurry consistance. Brush in into pores extensivly with srubber - Color: grey.
CORROSION PROTECTION:
Thoroughly brush undergrounds, metals, reinforcements completely twice.
HK 1 ETCHING PRIMER can be used for overhead works and moisted surfaces.
- Processing Time: 20C - 1 hour
Waiting time before second coating: approx. 6 hours - target thickness > 1 mm
Waiting time before grouting: ca. 6 hours.
A third coating is recommended, apply the grout wet on wet.
TABELLE !!$$&
It is very important for the surface to stay wet until setting (usually 3 days).
Prevent from the influence of wind, sun, and partial heating.
To prevent premature evaporation of water; flood, water atomization, windproof foils.
Alternatively you can use OF 1 SURFACE PROTECTION.
FE 1 Floor Screed
mineral - calcium-free - cement bound - ready-made
FE 1 FLOOR SCREED is suitable for layer thicknesses from 5 mm, depending on the
substrate. FE 1 FLOOR SCREED can be used up to 10 cm.
Provided by normal surface conditions, FE 1 FLOOR SCREED does not requirea primer
coat, is poured directly onto the matt damp, clean surface , distributed and vented with a
spiked roller and leveled (alternatively with nail boards). The surface can be sanded finely
ground.
FE 1 FLOOR SCREED is easily universally applicable, economical and has a high
resistance against strong chemicals, frost and de-icing salt - DIN1045 Section 6.5.7.
APPLICATIONS
Compensation screeds, coatings,
concrete floors, driveways and
industrial warehouses, working
fields, cabins, parking decks,
garages and balconies, interior
terraces and basements
PROCESSING
UNDERSURFACE: PROCESSING:
Clean thoroughly, remove loose and unsound Pour FE 1 FlOOR SCREED on the matt damp
parts and cement slurries. The surface must surface or on the bonding layer and with a height
be sustainable, reach a sufficient abrasion adjustable surface squeegee or rubber blade on large
resistance > 1.5 N / mm and meet all the surface distribute and equalize. shipment with a
requirements for concrete repair. spiked
Pre-soak to saturation at least 6 hours prior to Vent evenly with a spiked roller within 10 minutes.
processing. The processing must be completed within 20
Leave surface rough. Compensate deep bumps and minutes (20 C).
breakouts with BM 1 BLITZ GROUT. Do not apply in direct sunlight and protect from
Adopt joints of the substructure. drafts.
Immediately after venting, uniformly sprinkle
BONDING: abrasion-resistant and slip-resistant surfaces with
dry quartz sand (0,2 - 0,7 mm).
On even undersurface no bonding is required. Sweep off excess sand earliest after 12 hours. Wet
For highly absorbent undergrounds, use HK 1 the surface again.
PRIMER.
PUMPING:
MIXING:
FE 1 FlOOR SCREED can also be pumped on large
FE 1 FlOOR SCREED is a high-speed compulsory surfaces. Segregation does not occur.
mixer (eg. 45 U / min 150 l mixing volume), mixed
homogeneously with the specified amount of water. POST-TREATMENT:
First, fill three quarters of the required amount of
water, then add mortar and mix for 3 minutes,add If exposed to solar, wind or draft, protect the surface
the remaining water and mix another 4 minutes. against deydration with OF 1.
Mix the amount of mortar which can be processed
within 20 minutes. CLEANING:
Paving and jointing grouts are ready-mixed grouts with a balanced grain structure,
grains are swept into the grouts.
Before processing, it is advisable to apply a POS 1 paved surface protection.
For heavily loaded surfaces, each type can also be supplied with steel fibers.
PM are available in variations of grains from 0 to 8 mm. Setting times vary from 5
minutes up to 4 hours.
DESCRIPTION OF ABBREVIATIONS
z: cement bound
k: synthetic bound
tz: trass cement
u: water resistant
h: resin bound
3: up to 3 mm grains
EXAMPLE
PM TZu 3 / 150 = PAVING AND JOINT GROUT with trass cement, water
resistant, 3 mm largest grains, setting time 1 hour and 30 minutes
Additional program:
KSH 1 GRIT AND GRAVEL HARDENING RESIN, sprayable, pourable
Floors
Arnfried Pagel pers. Ing. G m b H & Co. KG
Technical Products and Consulting
D 10825 Berlin Kufsteiner Str. 10 Tel (030) 398 76 780 Fax (030) 398 76 78
E-Mail: office@arnfried-pagel.de www.arnfried-pagel.de
37
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
P 22 Armoured floor
chloride free - cement bound - ecological
GRAINS 0-4 mm
P 22 ARMOURED FLOOR consists of selected mineral aggregates and a corresponding
portion of silicon grains.
P 22 ARMOURED FLOOR surface group A (DIN 1100), ensures a low abrasion and a
surface elasticity and impact resistance due to its share of silicon grains.
P 22 ARMOURED FLOOR
Packaging: 25 kg
Storage: 1 year
After creating a gripping, solid surface, concrete quality must correlate to at least B 25,
with an upper surface strength of> 1.5 N / mm.
Before applying P 22 ARMOURED FLOOR, water the entire surface thoroughly. The
surface must be wiped until it is damp wet without puddles.
Next step:
Mix HK 1 ETCHING PRIMER to dough and scrub in. If under certain circumstances it is
not possible to water before applying, EH 1 EPOXY RESIN can be applied.
Mixing:
Post-treatment:
The surface must be protected from sun, wind, drafts and against premature water
evaporation. This is best done by watering the surface and/or regular wetting, ideally with
additional foil covering.
FLUMY 2000
permanently elastic, cement-, synthetic- and rubber bound grout
FLUMY 2000 is well suited for preventing disturbance by noise, concussion and
vibration.
On the bases of its strong adhesion and permanent elasticity, FLUMY 2000 is designed
for setting first stones, tailings, plates and to fill joints and cracks caused by static.
FLUMY 2000 is also used as buffering grout between concrete and steel, and for parts
that are exposed to vibration.
FLUMY 2000 is shock absorbing beneath driveways (plates, iron) and as a base for
profiled rails.
FLUMY 2000 is used in particular as a buffer beneath the foundation plates of precision
machines and laboratory balances.
It is to be noted that the benefits of Flumy 2000 has been proven especially for
preventing noise transmission of vibrating parts like tubes and pipes.
FLUMY 2000 is a product that can be the only solution in extremely critical situations
like crack bridging, hit strains and machine noise pollution.
Epoxy resins
Arnfried Pagel pers. Ing. G m b H & Co. KG
Technical Products and Consulting
D 10825 Berlin Kufsteiner Str. 10 Tel (030) 398 76 780 Fax (030) 398 76 78
E-Mail: office@arnfried-pagel.de www.arnfried-pagel.de
41
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
EH / Crack
PROPERTIES: AREAS OF APPLICATION:
Once cured, resistant to: EH/RISS EPOXY RESIN is a binder for grouts and
Water, sea water and sewage, ferner gegen coatings.
many alkalis, diluted acids, salt solutions, Universal adhesion even on wet or with residual
mineral oils, lubricants and fuels moisture. Priming and sealing.
and many solvents.
Under UV exposure - due to binder -
tone changes can occur.
low viscosity
TECHNICAL DATA:
high capillarity
EH/Crack Comp.Strength Bend. tensile strength
days 1 3 28 56 1 3 28 56
N/mm2 12 41 85 86.53 10 19 25 32.2
Typ EH/Crack tap water suitable min. temp. for processing ground +5C
Mixing ratio resin:hardener 1:1 density (23C/50% relative air moisture) kg/dm3 1.10
Color tone transparent /slightly yellowish Hazard Class : NONE see safety data sheet
Viscosity at 10C ca 5
at 20C ca 75
PROPERTIES AEREAS OF
APPLICATION
Deep Impregnation
Deep impregnations,
shock-resistant restoration,
ET 1 Deep Impregnation for dry and a little porous soils
solidifying and backfilling;
ET 10 f Deep Impregnation for moist and a little porous soils usage depending on
absorbency ,possibly the
ET 2 Deep Impregnation for dry, very porous soils same procedure is to be
ET 20 f Deep Impregnation for moist , very porous solis repeated
Screed
surface levelling for direct
ESP 2 Screed for dry soils self-priming adhering coating or for smallest to
large-surface repairings
ESP 22 f Screed for moist soils self-priming and adhering
ESP 30 Screed for die-stamping and damming
Min. hours
Mixing Viskosity
Shore hardness
Skid Resistance
Soil temerature
Adhasion Strength
Bending Strength
Compr. Strength
Accessible
Packeging
Revisable
Mix. Ratio
Abrasion
Stretch
Curing
Pot life
Usage
7:4 250 + 5C 50 > 2,5 24 24 7 200 11
1:1 10 + 5C 300 > 2,5 3 - 24 3 -24 300 10
4:1 40 + 5C 480 > 2,5 2 - 24 2 - 24 7 300 10
1:1 10 + 5C 300 > 2,5 3 - 24 3 - 24 7 300 10
1L=
17,9:1 + 6C 45 90 75 >4 D 98 5,1 20 20 7 10
1L=
17,9:1 + 6C 45 90 75 >4 D 95 5,2 10 - 13 20 20 7 10
1L=
17,9:1 + 6C 45 90 75 >4 D 98 20 20 7 10
depending on hardness, shape and size of the grain
1L=
2:1 700 + 5C 30 100 75 >4 D 97 4,9 6 - 24 6 - 24 7 10,5
1L=
2,3 : 1 1000 +10C 20 90 75 >4 D 95 4,6 4 - 24 4 - 24 7 9,9
1L=
1:1 500 + 5C 80 60 60 >4 D 60 25 % 12 - 24 24 7 10
1L=
2:1 700 + 5C 30 80 75 >4 D 93 4,5 3% 6 - 24 6 - 24 7 10,5
4 : 1 8000 + 5C 70 > 2,5 40 % 24 24 7 300 10
1L=
17,9:1 +10C 45 100 75 > 2,5 D100 4,0 20 20 7 10
5 : 1 7000 + 5C 40 80 75 >4 D 99 4,5 12 - 24 24 7 350 9,6
17,9:1 + 5C 90 70 > 2,5 D 98 4,2 20 20 7 10
Each Epoxy resin or epoxy ressin products has to be sufficiently mixed free of streaks.
The advantage of epoxy resin is his large application possibility. It is moisture and alkali re-
sistant.
High point loadable, abrasion-resistant, chemical resistant, free of cracks, repairing and clea-
ning advantages are more advantages of these resin products.
Epoxid-Harze und deren Produkte, die ber lngere Zeit witterungsbedingter UV-Strah-
lung ausgesetzt sind, sollten mit EUV-Decklack, UV-, licht- und witterungsbestndig,
dauerhaft geschtzt werden.
Polyurethane
& Acrylate
Arnfried Pagel pers. Ing. G m b H & Co. KG
Technical Products and Consulting
D 10825 Berlin Kufsteiner Str. 10 Tel (030) 398 76 780 Fax (030) 398 76 78
E-Mail: office@arnfried-pagel.de www.arnfried-pagel.de
46
Arnfried Pagel GmbH & Co. KG Pers. Ing. Technical Products and Consulting
PROPERTIES APPLICATIONS
Deep Impragnation
Deep impragnation,
Deep impragnations are done with epoxy resin only. restoration, solidifying,
ET There is a risk of saponification and alkali corrosion for backfilling, shock resistant.
polyurethane - see: epoxy -resin systems-
Primer
Deep impragnations are done with epoxy resin only.
EG There is a risk of saponification and alkali corrosion for
polyurethane - see: epoxy -resin systems-
Polyurethan-Resin
PU 1 Base resin for industrial floors and repairing grout Resins for filling and inter-
mediate levels, garages and
PU 10 Base resin, crack bridging, elastically workshops
PU B floor coatings availabe in all colours for offices and sales areas
Polyurethan-Grout
for warehouses and sales
PU M ready to use- grout, grain size 0, 03, 05, 1, 2, 3, 5 mm areas, containers, pits and
industrial roads
PU FM fine grout coating, self-levelling
PURI 1 Crack injection resin / PU-foam, water stopping constant crack gluing
Acrylate resin
Shore hardness
Skid Resistance
Soil temerature
Adhasion Strength
Bending Strength
Compr. Strength
Accessible
Packeging
Revisable
Mix. Ratio
Abrasion
Stretch
Curing
Pot life
Usage
7:1 250 + 5C > 2,5 24 24 7 200 11
1L=
6:1 +7 C 7 30 65 31 > 2,5 D 70 5,5 3% 10
1L=
6:1 +7C 30 55 33 >4 D 65 5,7 3% 0,5 - 1 5 - 24 7 10
5:1 800 +5C 30 > 2,5 D 65 6,0 1,5 % 0,5 - 1 5 - 24 7 150 10
Acrylate - Resin
1:1
- -15C 30 65 34 > 2,5 D 67 5,5 0,1 - 6 3 - 6 1-2 1000 10
1 : 10
Examples of use
The advantage of epoxy resin is a large application possibility. From elastic to solid,
it is crack bridging and chemical resistant.
High point loadable, abrasion-resistant, chemical resistant, free of cracks, repairing and
cleaning advantages are a nother characteristic of polyurethan products.
MAC 1 Methacrylate
point pressure resistant - stable for vibration - for interior or exterior use
- water resistant
MAC 1 METHACRYLATE is a colorless reaction resin made of two components on the basis
of methyl methacrylate. Special features include a high -viscosity modification with medium
reactivity and flexible adjustment.
MAC 1 has been specifically designed for repairs in heavy industry and can also be used
where resistance to below 0 C is a prerequisite.
MAC 1 Coatings must be prepared with an MAG PRIMER and sealed with MAV.
PROCESSING:
In case of emaciation, chose a grading curve which guarantees a complete filling of voids, thus
guaranteeing the required interlacing of the material.
SURFACE PREPARATION:
Clean the surface thoroughly of loose particles and dirt. The prerequisite for
applying the primer is a dry and dust free surface.
MIXING:
SAFETY PRECAUTIONS:
If there is skin contact with a hand cleaner, rinse sufficiently. For eye contact, rinse
and consult a doctor.
Fire protection grout meets the highest standard of Class A and DIN 4102.
Examples for application:
For casting for force transmitting and fire fortified compounds in reinforced concrete, as well as
for backfilling of door frames and between walls and lintels.
This grout corresponds to class F90, 90 min. fire resistance and complies with EN 13501-1.
Examples for application:
Props and joists, walls, ceilings and stairs.
Potting and grouted wall penetrations, fire doors, fire protection flap, pipe penetrations.
All our products are working capital and quality controlled. Our data sheets provide more