You are on page 1of 1

 The life of bearing oil is directly related to its temperature.

 The rule of thumb used by the SKF 
Bearing Company, is that the service life of an oil is estimated to be 30 years at 30 degrees 
Centigrade (86° F) and it's life is cut in half for each 10 degree Centigrade (18 F) temperature 
increase. This corresponds to : 

o A life of 3 months at 100 C. (212 F.) 

o A life of 6 months at 90 C. (195 F.) 

o A life of 12 months at 80 C. ( 176 F.) 

These numbers assume that the lubricating oil is not being contaminated by water from one or all of the 
following sources: 

 Packing leakage 

 The water hose used to wash the packing leakage away from the pump area. 

 Aspiration, as moisture laden air enters the bearing case. 

An automobile engine running at 1750 rpm. would cover about 100,000 miles (160,000 kilometers) 
every 2000 hours (83 days in the life of a constantly running pump ). Auto manufacturers recommend 
changing their automatic transmission oil every 25,000 miles ( 40,000 kilometers) 

APPLICATION 

 Use Centerline pump designs when the pumping temperature exceeds 200 degrees Fahrenheit 
(100° C). This design will allow the wet end of the pump to expand in two directions instead of 
from the feet up, destroying the wear rings.. 

 Try to buy pumps with a Suction Specific Speed (SSS) below 8,500 (10,000 metric) Do not buy 
pumps with a SSS over 12,000 ( metric 16,500) unless you're pumping hot water or mixed 
hydrocarbons. If you have a double suction pump you can divide the SSS number by 2 

 Do not specify a pump with the largest impeller available . Give yourself an additional 5% or 10% 
you might need it. 

 The maximum viscosity a centrifugal pump can handle would be a product similar to 30 weight 
oil at room temperature. 

 Use a variable speed pump if your head is mainly system head. Circulating hot or cold water 
would be typical applications. If you have a high static or pressure head, as is the case with a 
boiler feed pump, the variable speed will not be of much help in keeping you on or near the best 
efficiency point. 

 Pumps piped in series must have the same capacity (impeller width and speed) 

 Pumps piped in parallel must have the same head (impeller diameter and speed ) 

 Use a rotary positive displacement pump if your capacity is going to be less than 20 gpm.(4,5 
cubic meters per hour) 