You are on page 1of 232

PROJECT: KUDGI STTP-

STAGE-1 (3 X 800MW)-
CW SYSTEM
EQUIPMENT PACKAGE

NTPC DOC NO.9573-133-PVI-B-015


REV: R3.
DATE : 21.10.2015

Digitally signed
Signature Not Verified
by PRADEEP
CHANDEKAR
Date: 2015.11.03
09:57:48 IST
Reason: CAT I
Location:
NTPCEOC

XYLEM WATER SOLUTIONS INDIA PVT LTD


Plot no.731, GIDC Savli, Manjusar, Savli road,
Vadodara-391 770
PH.: +91 2667 265800,
Website: http://www.xyleminc.com,

Prepared By: smv / xylem / 21.09.15


COMPLIANCE REPORT
Project KUDGI SUPER THERMAL POWER PROJECT, S

TAGE - I (3 x 800 MW)

Client NTPC LIMITED.

Contractor Xylem Water Solution India Pvt Ltd

Title Compliance sheet for Flow meter


Equipment
GA & Datasheet for Electromagnetic flowmeter
Descr.

NTPC Drawing
9573-133-PVI-B-015-R3 dated 21.10.2015
no & Revision

Sr .No. NTPC comments on R1 Xylem/E&H compliance


Accuracy and Repeatability can not be calculated. It is the
performance specification and derived after the calibration tests in
The accuracy of the instrument should the accredited laboratory. Every manufacturer specifies the error in
be better than +/-0.5% of calibrated measurement of particular instrument based on manufacturing
span. However, as per catalogue, it is standards and mechanical tolerance.
indicated as +/-0.5% o.r. +/-1mm/s.
Optionally, +/-0.2% o.r. +/-2mm/s is e.g. Mag meter : It is basically a device which measures the velocity
also mentioned. Please clarify the of fluid within the predefined cross sectional area. Every
offered instrument's accuracy. measurement has some error due to some manufacturing tolerance
1 and limitations. So apart from base accuracy ( e.g 0.5% or 0.2% ) ,
Please clarify the significance of 2 mm/s there is an error of velocity measurement +/- 2 mm/sec. This should
in the above. please note that as per be added in to the base accuracy of the meter.
specification the accuracy should be +/-
0.5% of calibrated span or better. In If mag meter is measuring velocity of 2 m/sec than there could be
view of the same, please clarify ( with error of +/- 2 mm/sec in that measurement which is an additional
the help of suitable calculations ), how error of +/- 0.1%. Hence the worst case accuracy would be +/-
the totoal error complies to the specified 0.3% in given example. Refer to below screen shot of applicator
value. which confirms this calculation.

COMPLIANCE REPORT
Project KUDGI SUPER THERMAL POWER PROJECT, S

TAGE - I (3 x 800 MW)

Client NTPC LIMITED.

Contractor Xylem Water Solution India Pvt Ltd

Title Compliance sheet for Flow meter


Equipment
GA & Datasheet for Electromagnetic flowmeter
Descr.

NTPC Drawing
9573-133-PVI-B-015-R3 dated 21.10.2015
no & Revision

Sr .No. NTPC comments on R1 Xylem/E&H compliance

Please note that the offered


instrument should be suitable for 5%
to 100% RH in line with specifications
requirement. Please clarify how this
requirement is met by the offered
transmitters.

The given declaration is not adequate


Please find the certificate against the humidity factor for your kind
2 as neither model no nor the RH range is
reference.
indicated. Moreower, we understand
that offered products are new product
line of E&H, while the certificate belongs
to year 2010.
please clarify that the offered models
meet the RH requirements stated in the
specification and furnish relevant
clarifiction from the OEM.

Please furnish a list of similar


installation and feedback on
Only PO copy is furnish, not
E&H are trying to get PTR from their customer. We will send the
3 performance certificate.
same upon receipt of the same from E&H at the earliest.
M/s E&H to furnish relevant
performance certificates for the offered PTR given on email
products for similare applications. separately.

We understood that 230V AC raw power


supply shall be provided by NTPC to
Noted. As indicated in the PDB drawing, 230V power will be tapped
4 feed PDB as already indicated in PDB
from PDB.
drawing. Xylem will tap power supply
from this PDB
Indicate accuracy values as per OEM Noted. Accuracy is indicated in revised data sheet.
catalogue.
5

Also, indicate Noted. Indicated in the revised data sheet.


a) repeatability
6 b) Relative Humidity range &
c) totalizers
in each datasheet.

COMPLIANCE REPORT
Xylem Water Solution India Pvt. Ltd.

Project Kudgi Super Thermal Power Project Stage-1 (3x800 MW)


Sub Pump house wise details of Flow transmitters
NTPC doc no. 9573-133-PVI-B-015-R2
Sr. No. Area Location Instrument Description Model no. Rated flow Inst.Range Line Size Pressure Quantity Spares Total Qty Remarks
5L4C7H-AALHM0DHD1K0B+AA
1 CWPH On blow down line Full bore electromagnetic FT 0-635 m³/hr 0-13500 m³/hr 700 mm 4.6 1 1 2
Proline Promag L 400
On common Header & 5W4CT0-AABLHM0DHD4K0B+AA FT of DN 1000 is
2 MUWPH Full bore electromagnetic FT 0-12440 m³/hr 0-28000 m³/hr 1100 mm 19.5
both rising mains Proline Promag W 400 4 1 5 proposed.
5L4CT2-AALHM0DHD2K0B+AA
3 RAW PT On common header PT Full bore electromagnetic FT 0-7100 mᶾ/hr 0-40000 mᶾ/hr 1200 mm 5.1
Proline Promag L 400 1 1 2
5L4C6H-AALHM0DHD2K0B+AA
4 RAW ASH On common header Ash Full bore electromagnetic FT 0-1800 mᶾ/hr 0-9600 mᶾ/hr 600 mm 8.2
proline Promag L 400 1 1 2

Note: Instrument range mentioned in the table is as per Manufacturers instrument selection and sizing sheet.

FLOW TRANSMITTERS-PUMP HOUSE WISE DETAILS


Xylem Water Solution India Pvt. Ltd.
Kudgi Super Thermal Power Project Stage-1 (3x800 MW) C.W. System
Project :
Equipment Package
Supplier Endress+Hauser
NTPC Doc no. : 9573-133-PVI-B-015-R3, Date 20.10.2015
Model : 5L4C7H-AALHM0DHD1K0B+AA
Sub: DATA SHEET FOR FLOW TRANSMITTERS
Area : CWPH-BLOW DOWN LINE (Line size DN700)
Product Data
General information
Measuring task Flow (Volume)
General explosion-protection Information about currently available Ex versions
information (ATEX, FM, CSA, TIIS, IECEx, NEPSI, etc.) can be
supplied by your E+H Sales Center on request. All
explosion protection data are given in a separate
documentation which is availabe upon request.
Identification
Manufacturer name Endress+Hauser
Vendor Endress+Hauser
Product device / transmitter
Product type Electromagnetic flowmeter
Product name Proline Promag L 400
Order code 5L4C7H-AALHM0DHD1K0B+AA
Function and system design
Measuring principle Electromagnetic
Input characteristics
Measurement channels
Measured variable Flow
Measuring range
Lower range-limit 0.01 m/s
Upper range-limit 10.0 m/s
Output characteristics
Analog Output
Number 1
Output type Analog Output Galvanically isolated
Signal type 4-20 mA
Lower range value of signal 4.0 mA

Upper range value of signal 20.0 mA

Type of Instrument 4 Wire (Power supply - 230V AC)


Signal on alarm
Signal on alarm available yes
Signal on alarm configurable yes
Pulse/frequency output
Number 1
Output type Pulse-/Status-/Frequency Output
Electrical signal level 30.0 V
Pulse width min. 0.05 ms
Pulse width max. 2,000.0 ms
Frequency min. 0.0 Hz
Frequency max. 12,500.0 Hz
Totalizer 3 Nos

KUDGI_FT_CWPH-700.xls CWPH-FT-DN 700


Communication interface
HART Communication Interface
System Integration
Type of protocol HART
Power supply
Power input circuit (Universal - Either AC 100-240V or 24V DC can be used)
Voltage type DC voltage
Voltage type AC voltage
Supply voltage AC min. 100.0 V
Supply voltage DC max. 24.0 V
Supply voltage AC max. 240.0 V
Accuracy
Accuracy +/-0.2% or +/-2mm/s (0.08 in/s) %
Repeatability max +/-0.1% or +/- 0.5 mm/s (0.02 in/s)
Operating conditions
Installation
Inlet run (x DN) 10.0 x DN
Outlet run (x DN) 5.0 x DN
Installation instructions
Partially filled pipes Special requirements for partially filled pipes may be
necessary
Down pipes Special requirements in down pipes may be necessary

Environment
Ambient temperature °C min. -10.0 °C

Ambient temperature °F min. 14.0 °F

Ambient temperature °C max. 60.0 °C

Ambient temperature °F max. 140.0 °F

Vibrational resistance Acceleration up to 2 g by analogy with IEC 600 68-2-6

Electromagnetic compatibility As per IEC/EN 61326 and NAMUR Recommendation


21 (NE 21)
Humidity range 0-98 %
Process conditions
Process temperature in °C 0.0 °C
min.
Process temperature in °F 32.0 °F
min.
Process temperature in °C 80.0 °C
max.
Process temperature in °F 176.0 °F
max.
Medium conductivity min. 5.0 μS/cm
Flow min. (EU) 420.0 m3/h
Flow max. (EU) 13,500.0 m3/h
Flow min. (US) 1,900.0 USga/m
Flow max. (US) 60,000.0 USga/m
Low flow cut-off yes

KUDGI_FT_CWPH-700.xls CWPH-FT-DN 700


Mechanical construction
Connection housing / head
Housing type Transmitter housing
Housing design Compact
Material housing Polycarbonate
Ingress protection IP67
Cable entry signal line
Threaded cable entry NPT 1/2
Process connection
Type of connection Flange
Reference Standard for EN 1092-1
connection
Nominal diameter based on DN 700
EN/DIN
Nominal diameter based on 28"
ASME
Nominal pressure PN 6
Material process connection Carbon steel

Flowmeter (Electromagnetic)
Material electrodes based on 1.4435
EN/DIN
Material electrodes based on 316L
AISI
Flow tube material SS 304
Material lining Hard rubber
Inline device length in mm 700.0 mm
Inline device length in inch 27.6 inch
Operability
Display languages English
Certificate and approvals device / transmitter
Approval for general usage CE mark

Calibration
Calibration performed yes
Calibration type Standard
Comments
Accuracy shall be affected in case of min flow. Refer accuracy in attached sizing calculation.

KUDGI_FT_CWPH-700.xls CWPH-FT-DN 700


Xylem Water Solution India Pvt. Ltd.

Kudgi Super Thermal Power Project Stage-1 (3x800 MW) C.W. System Equipment
Project :
Package
Supplier Endress+Hauser
NTPC Doc no. : 9573-133-PVI-B-015-R3, Date 20.10.2015
Model : 5W4CT0-AABLHM0DHD4K0B+AA
Sub: DATA SHEET FOR FLOW TRANSMITTERS
MUWPH-COMMON HEADER & BOTH RISING MAINS LINE
Area : (Line size DN1000)
Product Data
General information
Measuring task Flow (Volume)
General explosion-protection Information about currently available Ex versions
information (ATEX, FM, CSA, TIIS, IECEx, NEPSI, etc.) can be
supplied by your E+H Sales Center on request. All
explosion protection data are given in a separate
documentation which is availabe upon request.
Identification
Manufacturer name Endress+Hauser
Vendor Endress+Hauser
Product device / transmitter
Product name Proline Promag W 400
Order code 5W4CT0-AABLHM0DHD4K0B+AA
Function and system design
Measuring principle Electromagnetic
Input characteristics
Measurement channels
Measured variable Flow
Measuring range
Lower range-limit 0.01 m/s
Upper range-limit 10.0 m/s
Output characteristics
Analog Output
Number 1
Output type Analog Output Galvanically isolated
Pulse/frequency output
Number 1
Output type Pulse/Frequency Output
Type of Instrument 4 wire (power supply 230V AC)
Repeatability 3 Nos
Communication interface
HART Communication Interface
System Integration
Type of protocol HART
Power supply
Power input circuit (Universal - Either 100-240V AC or 24V DC can be used )
Voltage type DC voltage
Voltage type AC voltage
Supply voltage AC min. 100.0 V
Supply voltage DC max. 24.0 V
Supply voltage AC max. 240.0 V
Accuracy
Accuracy +/-0.2% or +/-2mm/s (0.08 in/s) %
Repeatability max +/-0.1% or +/- 0.5 mm/s (0.02 in/s)

MUWPH-FT-DN1000
Operating conditions
Installation
Inlet run (x DN) 5.0 x DN
Outlet run (x DN) 2.0 x DN
Installation instructions
Partially filled pipes Special requirements for partially filled pipes may be
necessary
Down pipes Special requirements in down pipes may be necessary

Environment
Ambient temperature °C min. -10.0 °C
Ambient temperature °F min. 14.0 °F
Ambient temperature °C max. 60.0 °C
Ambient temperature °F max. 140.0 °F
Vibrational resistance Acceleration up to 2 g by analogy with IEC 600 68-2-6

Electromagnetic compatibility To EN 61326/A1 and NAMUR recommendation NE 21


Humidity range 0-98 %
Process conditions
Process temperature in °C min. 0.0 °C
Process temperature in °F min. 32.0 °F
Process temperature in °C max. 80.0 °C
Process temperature in °F max. 176.0 °F
Medium conductivity min. 5.0 μS/cm
Flow min. (EU) 850.0 m3/h
Flow max. (EU) 28,000.0 m3/h
Flow min. (US) 3,800.0 USga/m
Flow max. (US) 125,000.0 USga/m
Low flow cut-off yes
Mechanical construction
Connection housing / head
Housing type Transmitter housing, compact
Material housing Polycarbonate
Ingress protection IP67
Cable entry signal line
Threaded cable entry NPT 1/2
Process connection
Type of connection Flange
Reference Standard for connection EN 1092-1
Nominal diameter based on EN/DIN DN 1000
Nominal diameter based on ASME 40"
Nominal pressure PN 25
Material process connection Carbon steel
Flowmeter (Electromagnetic)
Material electrodes based on EN/DIN 1.4435
Material electrodes based on AISI 316L
Material lining Hard rubber
Flow tube materials SS 304
Operability
Display languages English
Certificate and approvals device / transmitter
Approval for general usage CE mark
Calibration
Calibration performed yes
Calibration type Standard
Comments
As revealed by all approved vendors,the pipe size of 1100 is non standard for flow transmitter. Hence Meter size of
1000 mm is considered. Suitable reducers/expanders etc will be used in pipe line to match FT's. Refer velocity in
attached sizing calculation.

MUWPH-FT-DN1000
Xylem Water Solution India Pvt. Ltd.

Kudgi Super Thermal Power Project Stage-1 (3x800 MW) C.W. System
Project : Equipment Package
Supplier Endress+Hauser
NTPC Doc no. : 9573-133-PVI-B-015-R3, Date 20.10.2015
Model : 5L4C6H-AALHM0DHD2K0B+AA
Sub: DATA SHEET FOR FLOW TRANSMITTERS
RAW ASH PH-COMMON HEADER LINE (Line size DN
Area :
600)
Product Data
General information
Measuring task Flow (Volume)
General explosion-protection Information about currently available Ex versions
information (ATEX, FM, CSA, TIIS, IECEx, NEPSI, etc.) can be
supplied by your E+H Sales Center on request. All
explosion protection data are given in a separate
documentation which is availabe upon request.
Identification
Manufacturer name Endress+Hauser
Vendor Endress+Hauser
Product device / transmitter
Product type Electromagnetic flowmeter
Product name Proline Promag L 400
Order code 5L4C6H-AALHM0DHD2K0B+AA
Function and system design
Measuring principle Electromagnetic
Input characteristics
Measurement channels
Measured variable Flow
Measuring range
Lower range-limit 0.01 m/s
Upper range-limit 10.0 m/s
Output characteristics
Analog Output
Number 1
Output type Analog Output Galvanically isolated
Signal type 4-20 mA
Lower range value of signal 4.0 mA
Upper range value of signal 20.0 mA
Type of Instrument 4 wire (power supply 230V AC)
Signal on alarm
Signal on alarm available yes
Signal on alarm configurable yes
Pulse/frequency output
Number 1
Output type Pulse-/Status-/Frequency Output
Electrical signal level 30.0 V
Pulse width min. 0.05 ms
Pulse width max. 2,000.0 ms
Frequency min. 0.0 Hz
Frequency max. 12,500.0 Hz
Totalizer 3 Nos
Communication interface
HART Communication Interface
System Integration
Type of protocol HART
Power supply
Power input circuit (Universal- Either 100-240V AC or 24V DC power can be used)
Voltage type DC voltage
Voltage type AC voltage
Supply voltage AC min. 100.0 V
Supply voltage DC max. 24.0 V
Supply voltage AC max. 240.0 V

RAW ASH-FT-DN600
Accuracy
Accuracy +/-0.2% or 2mm/s (0.08 in/s) %
Repeatability max +/- 0.1% or 0.5 mm/s (0.02in/s)
Operating conditions
Installation
Inlet run (x DN) 10.0 x DN
Outlet run (x DN) 5.0 x DN
Installation instructions
Partially filled pipes Special requirements for partially filled pipes may be
necessary
Down pipes Special requirements in down pipes may be
necessary
Environment
Ambient temperature °C min. -10.0 °C
Ambient temperature °F min. 14.0 °F
Ambient temperature °C max. 60.0 °C
Ambient temperature °F max. 140.0 °F
Vibrational resistance Acceleration up to 2 g by analogy with IEC 600 68-2-
6
Electromagnetic compatibility As per IEC/EN 61326 and NAMUR
Recommendation 21 (NE 21)
Humidity 0-98 %
Process conditions
Process temperature in °C min. 0.0 °C
Process temperature in °F min. 32.0 °F
Process temperature in °C max. 80.0 °C
Process temperature in °F max. 176.0 °F
Medium conductivity min. 5.0 μS/cm
Flow min. (EU) 310.0 m3/h
Flow max. (EU) 9,600.0 m3/h
Flow min. (US) 1,400.0 USga/m
Flow max. (US) 44,000.0 USga/m
Low flow cut-off yes
Mechanical construction
Connection housing / head
Housing type Transmitter housing
Housing design Compact
Material housing Polycarbonate
Ingress protection IP 67
Cable entry signal line
Threaded cable entry NPT 1/2
Process connection
Type of connection Flange
Reference Standard for connection EN 1092-1
Nominal diameter based on EN/DIN DN 600
Nominal diameter based on ASME 24"
Nominal pressure PN 10
Material process connection Carbon steel
Flowmeter (Electromagnetic)
Material electrodes based on EN/DIN 1.4435
Material electrodes based on AISI 316L
Flow tube material SS 304
Material lining Hard rubber
Inline device length in mm 600.0 mm
Inline device length in inch 23.6 inch
Operability
Display languages English
Certificate and approvals device / transmitter
Approval for general usage CE mark
Calibration
Calibration performed yes
Calibration type Standard
Comments
The accuracy is gauranteed on rated flow (full bore flow)

RAW ASH-FT-DN600
Xylem Water Solution India Pvt. Ltd.

Kudgi Super Thermal Power Project Stage-1 (3x800 MW) C.W. System
Project :
Equipment Package
Supplier Endress+Hauser
NTPC Doc no. : 9573-133-PVI-B-015-R3, Date 20.10.2015
Model : 5L4CT2-AALHM0DHD2K0B+AA
Sub: DATA SHEET FOR FLOW TRANSMITTERS
Area : RAW PT -COMMON HEADER LINE (Line size DN 1200)
Product Data
General information
Measuring task Flow (Volume)
General explosion-protection information Information about currently available Ex versions
(ATEX, FM, CSA, TIIS, IECEx, NEPSI, etc.) can be
supplied by your E+H Sales Center on request. All
explosion protection data are given in a separate
documentation which is availabe upon request.

Identification
Manufacturer name Endress+Hauser
Vendor Endress+Hauser
Product device / transmitter
Product type Electromagnetic flowmeter
Product name Proline Promag L 400
Order code 5L4CT2-AALHM0DHD2K0B+AA
Function and system design
Measuring principle Electromagnetic
Input characteristics
Measurement channels
Measured variable Flow
Measuring range
Lower range-limit 0.01 m/s
Upper range-limit 10.0 m/s
Output characteristics
Analog Output
Number 1
Output type Analog Output Galvanically isolated
Signal type 4-20 mA
Lower range value of signal 4.0 mA
Upper range value of signal 20.0 mA
Type of Instrument 4 wire (Power supply 230V AC)
Signal on alarm
Signal on alarm available yes
Signal on alarm configurable yes
Pulse/frequency output
Number 1
Output type Pulse-/Status-/Frequency Output
Electrical signal level 30.0 V
Pulse width min. 0.05 ms
Pulse width max. 2,000.0 ms
Frequency min. 0.0 Hz
Frequency max. 12,500.0 Hz
Totalizer 3 Nos
Communication interface
HART Communication Interface
System Integration
Type of protocol HART
Power supply
Power input circuit (Universal - Either 100-240V AC or 24V DC power can be used)
Voltage type DC voltage
Voltage type AC voltage
Supply voltage AC min. 100.0 V
Supply voltage DC max. 24.0 V
Supply voltage AC max. 240.0 V

RAW PT-FT-DN1200
Accuracy
Accuracy +/-0.2% or +/-2mm/s (0.08 in/s) %
Repeatability max +/-0.1% or +/-0.5mm/s (0.02 in/s)
Operating conditions
Installation
Inlet run (x DN) 10.0 x DN
Outlet run (x DN) 5.0 x DN
Installation instructions
Partially filled pipes Special requirements for partially filled pipes may be
necessary
Down pipes Special requirements in down pipes may be
necessary
Environment
Ambient temperature °C min. -10.0 °C
Ambient temperature °F min. 14.0 °F
Ambient temperature °C max. 60.0 °C
Ambient temperature °F max. 140.0 °F
Vibrational resistance Acceleration up to 2 g by analogy with IEC 600 68-2-
6
Electromagnetic compatibility As per IEC/EN 61326 and NAMUR Recommendation
21 (NE 21)
Humidity range 0-98 %
Process conditions
Process temperature in °C min. 0.0 °C
Process temperature in °F min. 32.0 °F
Process temperature in °C max. 80.0 °C
Process temperature in °F max. 176.0 °F
Medium conductivity min. 5.0 μS/cm
Flow min. (EU) 1,250.0 m3/h
Flow max. (EU) 40,000.0 m3/h
Flow min. (US) 5,550.0 USga/m
Flow max. (US) 175,000.0 USga/m
Low flow cut-off yes
Mechanical construction
Connection housing / head
Housing type Transmitter housing
Housing design Compact
Material housing Polycarbonate
Ingress Protection IP 67
Cable entry signal line
Threaded cable entry NPT 1/2
Process connection
Type of connection Flange
Reference Standard for connection EN 1092-1
Nominal diameter based on EN/DIN DN 1200
Nominal diameter based on ASME 48"
Nominal pressure PN 10
Material process connection Carbon steel
Flowmeter (Electromagnetic)
Material electrodes based on EN/DIN 1.4435
Material electrodes based on AISI 316L
Material lining Hard rubber
Flow tube material SS 304
Inline device length in mm 1,200.0 mm
Inline device length in inch 47.2 inch
Operability
Display languages English
Certificate and approvals device / transmitter
Approval for general usage CE mark
Calibration
Calibration performed yes
Calibration type Standard
Comments
Accuracy shall be gauranteed in the rated full bore flow.

RAW PT-FT-DN1200
3 4

6
5

Housing : Compact NOTES.:-


1) All Dimensions are in mm
A
B

B
C

Qty. Process A B C D E F G H J
Ordercode Service
(Nos) Connection (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
D

5L4C7H-AALHM0DHD1K0B+AA CWPH 02 Nos. DN700 28" 193 103 90 167 571 1001 860 424 700
Flange PN6 EN1092-1

5L4CT2-AALHM0DHD2K0B+AA RAW PT 02 Nos. DN1200 48" 193 103 90 167 841 1569 1455 828 1200
Flange PN10 EN1092-1

5L4C6H-AALHM0DHD2K0B+AA RAW ASH 02 Nos. DN600 24" 193 103 90 167 506 896 780 290 600
Flange PN10 EN1092-1
E

E
Endress + Hauser (India) Pvt. Ltd.
02 Customer : Xylem Water Solution NTPC DOC NO.9573-133-PVI-B-015
People for Process Automation 01 E&H REF: EHI-2009215211/DIM-1/R00
Project ; Kudgi STPP (3 x 800MW) Sheet No:
7B, 7th Floor, Godrej One, 00 24-08-15 For Reference KMS SK SK DOCUMENT REF:
KUDGI
Pirojsha Nagar, Vikhroli (Eest),
Prepd. Chd. Appd. General Arrangement Drawing for 1/2
MUMBAI - 400 079 Rev. Date Description End User : NPTC (Promag L400)
By By By Scale : NTS
1 4 5 7
2

8
3 4

6
5

Decodification :

5L4C7H-AALHM0DHD1K0B+AA 5L4CT2-AALHM0DHD2K0B+AA 5L4C6H-AALHM0DHD2K0B+AA


A

Promag L 400, 5L4C7H, DN700 28" Promag L 400, 5L4CT2, DN1200 48" Promag L 400, 5L4C6H, DN600 24"
[AA]Approval: Non-hazardous area [AA]Approval: Non-hazardous area [AA]Approval: Non-hazardous area
[L]Power Supply: 100-240VAC/24VAC/DC [L]Power Supply: 100-240VAC/24VAC/DC [L]Power Supply: 100-240VAC/24VAC/DC
[H]Output; Input: 4-20mA HART, pulse/freq. [H]Output; Input: 4-20mA HART, pulse/freq. [H]Output; Input: 4-20mA HART, pulse/freq.
outputswitch output outputswitch output outputswitch output
[M]Housing: Compact, Polycarbonate [M]Housing: Compact, Polycarbonate [M]Housing: Compact, Polycarbonate
[0]Cable, Remote Version: Not used [0]Cable, Remote Version: Not used [0]Cable, Remote Version: Not used
[D]Electrical Connection: Thread NPT1/2 [D]Electrical Connection: Thread NPT1/2 [D]Electrical Connection: Thread NPT1/2
[H]Liner: Hard rubber [H]Liner: Hard rubber [H]Liner: Hard rubber
[D1K]Process Connection: PN6, carbon steel, flange [D2K]Process Connection: PN10, carbon steel, flange [D2K]Process Connection: PN10, carbon steel, flange
B

B
EN1092-1(DIN2501) EN1092-1(DIN2501) EN1092-1(DIN2501)
[0]Electrodes: 1.4435/316L [0]Electrodes: 1.4435/316L [0]Electrodes: 1.4435/316L
[B]Calibration Flow: 0.2% [B]Calibration Flow: 0.2% [B]Calibration Flow: 0.2%
[AA]Operation Language Display: English [AA]Operation Language Display: English [AA]Operation Language Display: English
C

C
D

D
E

E
02 Customer : Xylem Water Solution NTPC DOC NO.9573-133-PVI-B-015
Endress + Hauser (India) Pvt. Ltd.
People for Process Automation 01 Drg No. EHI-2009215211/DIM-1/R00
Project : Kudgi STTP (3 x 800MW)
7B, 7th Floor, Godrej One, 00 24-08-15 For Reference KMS SK SK
KUDGI
Document Title: Sheet No:
Pirojsha Nagar, Vikhroli (Eest),
Prepd. Chd. Appd. General Arrangement Drawing for 2/2
MUMBAI - 400 079 Rev. Date Description End User : NPTC (Promag L400)
By By By Scale : NTS
1 4 5 7
2

8
3 4

6
5

Housing : Compact NOTES.:-


1) All Dimensions are in mm
A

Decodification :

5W4CT0-AABLHM0DHD4K0B+AA
Promag W 400, 5W4CT0, DN1000 40"
[AA]Approval: Non-hazardous area
[B]Design: Insertion length longISO/DVGW until DN400,
DN450-2000 1:1.3
B

B
[L]Power Supply: 100-240VAC/24VAC/DC
[H]Output; Input: 4-20mA HART, pulse/freq.
outputswitch output
[M]Housing: Compact, Polycarbonate
[0]Cable, Remote Version: Not used
[D]Electrical Connection: Thread NPT1/2
[H]Liner: Hard rubber
[D4K]Process Connection: PN25, carbon steel, flange
EN1092-1(DIN2501)
[0]Electrodes: 1.4435/316L
C

[B]Calibration Flow: 0.2%


[AA]Operation Language Display: English
D

Qty. Process A B C D E F G H J K
Ordercode Service
(Nos) Connection (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

5W4CT0-AABLHM0DHD4K0B+AA MUWPH 05 Nos. DN 1000 40" 193 103 90 167 836 686 1522 1372 862 1300
Flange PN25 EN1092-1

Project : Thermal Power Project at NTPC


E

E
02 Customer : Xylem Water Solution NTPC DOC NO.9573-133-PVI-B-015
Endress + Hauser (India) Pvt. Ltd.
People for Process Automation 01 Drg No. EHI-2009215211/DIM-2/R00
Project : Kudgi STTP (3 x 800MW)
7B, 7th Floor, Godrej One, 00 24-08-15 For Reference KMS SK SK Document Title: Sheet No:
KUDGI
Pirojsha Nagar, Vikhroli (Eest),
Prepd. Chd. Appd. General Arrangement Drawing for 1/1
MUMBAI - 400 079 Rev. Date Description End User : NPTC (Promag W400)
By By By Scale : NTS
1 4 5 7
2

8
3 4

6
5

Electrical connection : 4-20mA HART, pulse/freq. outputswitch output


A

1 Supply voltage
2 Output 1 (26/27) and output 2 (24/25)
3 Output 3 (22/23) and input 1 (20/21)
B

B
Terminal No.1 : (L+/L) : AC 100 to 240 V, AC/DC 24 V
Terminal No.2 : (L-/N) : AC 100 to 240 V, AC/DC 24 V

Signal Cable:
Terminal No.26(+) / 27(-) = 4-20 mA HART (active),0-20 mA (active)
Terminal No.24(+) / 25(-) = Pulse/frequency output (passive)
Terminal No.22(+) / 23(-) = switch output (passive)
Terminal No.20(+) / 21(-) = --
C

Qty.
Ordercode Service
(Nos)

5L4C7H-AALHM0DHD1K0B+AA CWPH 02 Nos.


D

5L4CT2-AALHM0DHD2K0B+AA RAW PT 02 Nos.

5L4C6H-AALHM0DHD2K0B+AA RAW ASH 02 Nos.

5W4CT0-AABLHM0DHD4K0B+AA MUWPH 05 Nos.


E

E
Endress + Hauser (India) Pvt. Ltd.
02 Customer : Xylem Water Solution NTPC DOC NO.9573-133-PVI-B-015
People for Process Automation 01 Drg No. EHI-2009215211/ELE-1/R00
Project: Kudgi STTP (3 x 800MW) Sheet No:
7B, 7th Floor, Godrej One, 00 24-08-15 For Reference KMS SK SK
KUDGI
Pirojsha Nagar, Vikhroli (Eest),
Prepd. Chd. Appd. Electrical connection for 1/2
MUMBAI - 400 079 Rev. Date Description End User : NPTC (Promag L/W 400)
By By By Scale : NTS
1 4 5 7
2

8
 SIZING CALCULATION FOR CWPH BLOW DOWN LINE FLOW TRANSMITTER
 
Data Sheet

Applicator Sizing - Condensed (Flow) - LINE SIZE -DN 700


 
Project
Project NTPC_KUDGI STTP (3X800MW)
CW PH-FLOW TRANSMITTER SIZING CALCULATION
NTPC DOC. No. 9573-133-PVI-B-0CO15, REV-R1
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD
TAG Kudgi_FT_CWPH
Timestamp 26.08.2015 07:08 PM
Review number 26
Sales order number
Contact person ---
eMail: ---
Phone ---
Fax ---
 
General Parameters Operating Conditions
Fluid 0 Dummy-Liquid (Water) based on SP - minimum nominal maximum
MODIFIED- Requested Flow 635 1 270 2 200 m3/h
State Liquid Pressure 4.6 bar_g
Character Clean Temperature 50 °C
Abrasivity Not abrasive Density 1 000 kg/m3
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Viscosity 1 cP
Fluid Type Newtonian Sound velocity 1 549 1 549 1 549 m/s
Atmospheric Pressure 1.0132 bar_a Pressure (min/max) 4.6 4.6 bar_g
Standard EN/DIN/ISO Temp. (min/max) 50 50 °C
Vapor Pressure 0.1134 0.1134 0.1134 bar_a

Flowmeter Operating Conditions


Flowmeter Promag L 400 minimum nominal maximum
Flow Principle Electromagnetic Requested Flow 635 1 270 2 200 m3/h
Extended order code 5L4C7H-*******UD1K*B Velocity 0.46 0.919 1.592 m/s
Meter Size DN 700 Pressure loss 0 0 0 mbar
Operating range min. 0   m3/h Measured error Spec. 0.64 0.42 0.33 %
Operating range max. 13 500   m3/h Volume***
Material (sensor) *+DUGUXEEHU /LQHU(0...+0°C) Reynolds No. 642 59
Process connection* PN 6 EN 1092-1 (DIN2501)
general_sizing_flow_PRESSURE_RATING_HELP_flange_carbon
steel
PED category ** : Flowmeter excluded

*The user is responsible for the selection of process-wetted materials


in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM - 1 / 82
Applicator®: 10.21.00 / 149
Applicator Sizing - Flow - CW BD LINE-DN 700
Project : NTPC_KUDGI PROJECT- CW PUMP HOUSE-BLOW DOWN LINE
Customer: C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---

TAG : Kudgi_FT_CWPH
Timestamp: 26.08.2015 07:08 PM Review number: 26
Sales order number:

Tri-Size Sheet
General Parameters
Fluid 0 Dummy-Liquid (Water) based on SP -
MODIFIED-
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag L 400 Promag L 400 Promag L 400
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 600 DN 700 DN 800
Process connection* PN 6 EN 1092-1 (DIN2501) PN 6 EN 1092-1 (DIN2501) PN 6 EN 1092-1 (DIN2501)
Operating range min. 0 0 0 m3/h
Operating range max. 9 600 13 500 18 000 m3/h
Velocity at req. Flow min. 0.628 0.46 0.35 m/s
Velocity at req. Flow nom. 1.256 0.919 0.7 m/s
Velocity at req. Flow max. 2.176 1.592 1.213 m/s
Pressure loss at req. Flow min. 0 0 0 mbar
Pressure loss at req. Flow nom. 0 0 0 mbar
Pressure loss at req. Flow max. 0 0 0 mbar
Meas. error Vol. at req. Flow min.*** 0.66 0.72 0.79 %
Meas. error Vol. at req. Flow nom.*** 0.58 0.61 0.64 %
Meas. error Vol. at req. Flow max.*** 0.55 0.56 0.58 %
Meas. error Spec. Vol. at req. Flow min.*** 0.52 0.64 0.77 %
Meas. error Spec. Vol. at req. Flow nom.*** 0.36 0.42 0.49 %
Meas. error Spec. Vol. at req. Flow max.*** 0.29 0.33 0.36 %
Reynolds No. 751 121 642 590 560 762
Warnings / Messages
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM - 2 /8
2
Applicator®: 10.21.00 / 149
 
SIZING CALCULATION FOR MAKE UP WATER FLOW TRANSMITTERS
 
Data Sheet

Applicator Sizing - Condensed (Flow)-LINE SIZE -DN 1000


 
Project
Project NTPC_KUDGI STTP (3 X 800MW) MA E UP WATER PH
FLOW TRANSMITTERS FOR COMMON HEADER & RISING MAINS
NTPC DOC NO. 9573-133-PVI-B-015, REV-R1
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD
TAG Kudgi_FT_MUWPH
Timestamp 26.08.2015 07:08 PM
Review number 15
Sales order number
Contact person ---
eMail: ---
Phone ---
Fax ---
 
General Parameters Operating Conditions
Fluid 0 Dummy-Liquid (Water) based on SP - minimum nominal maximum
MODIFIED- Requested Flow 12 440 12 440 12 440 m3/h
State Liquid Pressure 19.5 bar_g
Character Clean Temperature 50 °C
Abrasivity Not abrasive Density 1 000 kg/m3
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Viscosity 1 cP
Fluid Type Newtonian Sound velocity 1 549 1 549 1 549 m/s
Atmospheric Pressure 1.0132 bar_a Pressure (min/max) 19.5 19.5 bar_g
Standard EN/DIN/ISO Temp. (min/max) 50 50 °C
Vapor Pressure 0.1134 0.1134 0.1134 bar_a

Flowmeter Operating Conditions


Flowmeter Promag W 400 minimum nominal maximum
Flow Principle Electromagnetic Requested Flow 12 440 12 440 12 440 m3/h
Extended order code 5W4CT0-********HD4K*B Velocity 4.453 4.453 4.453 m/s
Meter Size DN 1000 Pressure loss 0 0 0 mbar
Operating range min. 0   m3/h Measured error Spec. 0.24 0.24 0.24 %
Operating range max. 28 000   m3/h Volume***
Material (sensor) * Hard-Rubber-Liner (0...+80°C) Reynolds No. 4 426 308
Process connection* PN 25 EN 1092-1, ST 37-2 Flange
PED category ** : Attention! Warnings / Messages
1. This Flowmeter with the selected process connection is not available in
*The user is responsible for the selection of process-wetted materials the requested Category of PED. Please select an other process connection.
in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -3/8-
Applicator®: 10.21.00 / 149
Applicator Sizing - Flow - MUW - DN 1000
Project : NTPC_KUDGI PROJECT- MUW PUMP HOUSE - FT FOR COMMON HEADER & RISING MAIN
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---

TAG : Kudgi_FT_MUWPH
Timestamp: 26.08.2015 07:08 PM Review number: 15
Sales order number:

Tri-Size Sheet
General Parameters
Fluid 0 Dummy-Liquid (Water) based on SP -
MODIFIED-
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag W 400 Promag W 400 Promag W 400
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 900 DN 1000 DN 1200
Process connection* PN 25 EN 1092-1, ST 37-2 PN 25 EN 1092-1, ST 37-2 n.a.
Operating range min. 0 0 0 m3/h
Operating range max. 22 500 28 000 40 000 m3/h
Velocity at req. Flow min. 5.542 4.453 3.071 m/s
Velocity at req. Flow nom. 5.542 4.453 3.071 m/s
Velocity at req. Flow max. 5.542 4.453 3.071 m/s
Pressure loss at req. Flow min. 0 0 0 mbar
Pressure loss at req. Flow nom. 0 0 0 mbar
Pressure loss at req. Flow max. 0 0 0 mbar
Meas. error Vol. at req. Flow min.*** 0.52 0.52 0.53 %
Meas. error Vol. at req. Flow nom.*** 0.52 0.52 0.53 %
Meas. error Vol. at req. Flow max.*** 0.52 0.52 0.53 %
Meas. error Spec. Vol. at req. Flow min.*** 0.24 0.24 0.27 %
Meas. error Spec. Vol. at req. Flow nom.*** 0.24 0.24 0.27 %
Meas. error Spec. Vol. at req. Flow max.*** 0.24 0.24 0.27 %
Reynolds No. 4 937 991 4 426 308 3 675 647
Warnings / Messages 1. This Flowmeter with the 1. This Flowmeter with the 1. This Flowmeter with the
selected process connection is selected process connection is selected process connection is
not available in the requested not available in the requested not available in the requested
Category of PED. Please select Category of PED. Please select Category of PED. Please select
an other process connection. an other process connection. an other process connection.
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -4/8-
Applicator®: 10.21.00 / 149
SIZING
  CALCULATION FOR RAW-PT FLOW TRANSMITTERS
 
Data Sheet

Applicator Sizing - Condensed (Flow)-LINE SIZE DN 1200


 
Project
Project NTPC_KUDGI STTP (3 X 800MW) -RAW PT
FLOW TRANSMITTERS FOR COMMON HEADER
NTPC DOC NO. 9573-133-PVI-B-015, REV-01
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD
TAG Kudgi_FT_RAW PT
Timestamp 26.08.2015 07:08 PM
Review number 19
Sales order number
Contact person ---
eMail: ---
Phone ---
Fax ---
 
General Parameters Operating Conditions
Fluid 0 Dummy-Liquid (Water) based on SP - minimum nominal maximum
MODIFIED- Requested Flow 7 100 7 100 7 100 m3/h
State Liquid Pressure 5.1 bar_g
Character Clean Temperature 50 °C
Abrasivity Not abrasive Density 1 000 kg/m3
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Viscosity 1 cP
Fluid Type Newtonian Sound velocity 1 549 1 549 1 549 m/s
Atmospheric Pressure 1.0132 bar_a Pressure (min/max) 5.1 5.1 bar_g
Standard EN/DIN/ISO Temp. (min/max) 50 50 °C
Vapor Pressure 0.1134 0.1134 0.1134 bar_a

Flowmeter Operating Conditions


Flowmeter Promag L 400 minimum nominal maximum
Flow Principle Electromagnetic Requested Flow 7 100 7 100 7 100 m3/h
Extended order code 5L4CT2-*******HD2K*B Velocity 1.738 1.738 1.738 m/s
Meter Size DN 1200 Pressure loss 0 0 0 mbar
Operating range min. 0   m3/h Measured error Spec. 0.32 0.32 0.32 %
Operating range max. 40 000   m3/h Volume***
Material (sensor) * Hard-Rubber-Liner (0...+80°C) Reynolds No. 2 089 111
Process connection* PN 10 EN 1092-1 (DIN2501)
general_sizing_flow_PRESSURE_RATING_HELP_flange_carbon
steel
PED category ** : Flowmeter excluded

*The user is responsible for the selection of process-wetted materials


in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -5/8-
Applicator®: 10.21.00 / 149
Applicator Sizing - Flow - RAW PT -DN 1200
Project : NTPC_KUDGI -RAW PT PUMP HOUSE - FLOW TRANSMITTERS FOR COMMON HEADER
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD. Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---

TAG : Kudgi_FT_RAW PT
Timestamp: 26.08.2015 07:08 PM Review number: 19
Sales order number:

Tri-Size Sheet
General Parameters
Fluid 0 Dummy-Liquid (Water) based on SP -
MODIFIED-
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag L 400 Promag L 400 Promag L 400
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 1000 DN 1200 DN 1400
Process connection* PN 10 EN 1092-1 (DIN2501) PN 10 EN 1092-1 (DIN2501) PN 10 EN 1092-1 (DIN2501)
Operating range min. 0 0 0 m3/h
Operating range max. 28 000 40 000 55 000 m3/h
Velocity at req. Flow min. 2.506 1.738 1.278 m/s
Velocity at req. Flow nom. 2.506 1.738 1.278 m/s
Velocity at req. Flow max. 2.506 1.738 1.278 m/s
Pressure loss at req. Flow min. 0 0 0 mbar
Pressure loss at req. Flow nom. 0 0 0 mbar
Pressure loss at req. Flow max. 0 0 0 mbar
Meas. error Vol. at req. Flow min.*** 0.54 0.56 0.58 %
Meas. error Vol. at req. Flow nom.*** 0.54 0.56 0.58 %
Meas. error Vol. at req. Flow max.*** 0.54 0.56 0.58 %
Meas. error Spec. Vol. at req. Flow min.*** 0.28 0.32 0.36 %
Meas. error Spec. Vol. at req. Flow nom.*** 0.28 0.32 0.36 %
Meas. error Spec. Vol. at req. Flow max.*** 0.28 0.32 0.36 %
Reynolds No. 2 508 603 2 089 111 1 791 092
Warnings / Messages
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -6/8-
Applicator®: 10.21.00 / 149
 SIZING CALCULATION FOR RAW ASH FLOW TRANSMITTERS
 
Data Sheet

Applicator Sizing - Condensed (Flow)-LINE SIZE DN 600


 
Project
Project NTPC_KUDGI STTP (3X800MW) - RAW ASH PH
FLOW TRANSMITTERS FOR COMMON HEADERS
NTPC DOC No. 9573-133-PVI-B-015, REV-R1
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD
TAG Kudgi_FT_RAW ASH
Timestamp 26.08.2015 07:09 PM
Review number 17
Sales order number
Contact person ---
eMail: ---
Phone ---
Fax ---
 
General Parameters Operating Conditions
Fluid 0 Dummy-Liquid (Water) based on SP - minimum nominal maximum
MODIFIED- Requested Flow 1 800 1 800 1 800 m3/h
State Liquid Pressure 8.2 bar_g
Character Clean Temperature 50 °C
Abrasivity Not abrasive Density 1 000 kg/m3
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Viscosity 1 cP
Fluid Type Newtonian Sound velocity 1 549 1 549 1 549 m/s
Atmospheric Pressure 1.0132 bar_a Pressure (min/max) 8.2 8.2 bar_g
Standard EN/DIN/ISO Temp. (min/max) 50 50 °C
Vapor Pressure 0.1134 0.1134 0.1134 bar_a

Flowmeter Operating Conditions


Flowmeter Promag L 400 minimum nominal maximum
Flow Principle Electromagnetic Requested Flow 1 800 1 800 1 800 m3/h
Extended order code 5L4C6H-*******HD2K*B Velocity 1.78 1.78 1.78 m/s
Meter Size DN 600 Pressure loss 0 0 0 mbar
Operating range min. 0   m3/h Measured error Spec. 0.31 0.31 0.31 %
Operating range max. 9 600   m3/h Volume***
Material (sensor) * Hard-Rubber-Liner (0...+80°C) Reynolds No. 1 064 582
Process connection* PN 10 EN 1092-1 (DIN2501)
general_sizing_flow_PRESSURE_RATING_HELP_flange_carbon
steel
PED category ** : Flowmeter excluded

*The user is responsible for the selection of process-wetted materials


in view of their corrosion resistance. Endress+Hauser makes no
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -7/8-
Applicator®: 10.21.00 / 149
Applicator Sizing - Flow - RAW ASH -DN 600
Project : NTPC_KUDGI STTP- RAW ASH PUMP HOUSE - FT FOR COMMON HEADERS
Customer: XYLEM WATER SOLUTIONS INDIA PVT LTD C.Project No.: 0
Contact person: --- Phone: --- Fax: ---
eMail: ---

TAG : Kudgi_FT_RAW ASH


Timestamp: 26.08.2015 07:09 PM Review number: 17
Sales order number:

Tri-Size Sheet
General Parameters
Fluid 0 Dummy-Liquid (Water) based on SP -
MODIFIED-
State Liquid
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Fluid Type Newtonian

Sizing and Calculated Results


Next Smaller Size Current Size Next Bigger Size
Flow meter Promag L 400 Promag L 400 Promag L 400
Flow Principle Electromagnetic Electromagnetic Electromagnetic
Meter Size DN 500 DN 600 DN 700
Process connection* PN 10 EN 1092-1 (DIN2501) PN 10 EN 1092-1 (DIN2501) PN 10 EN 1092-1 (DIN2501)
Operating range min. 0 0 0 m3/h
Operating range max. 6 600 9 600 13 500 m3/h
Velocity at req. Flow min. 2.588 1.78 1.303 m/s
Velocity at req. Flow nom. 2.588 1.78 1.303 m/s
Velocity at req. Flow max. 2.588 1.78 1.303 m/s
Pressure loss at req. Flow min. 0 0 0 mbar
Pressure loss at req. Flow nom. 0 0 0 mbar
Pressure loss at req. Flow max. 0 0 0 mbar
Meas. error Vol. at req. Flow min.*** 0.54 0.56 0.58 %
Meas. error Vol. at req. Flow nom.*** 0.54 0.56 0.58 %
Meas. error Vol. at req. Flow max.*** 0.54 0.56 0.58 %
Meas. error Spec. Vol. at req. Flow min.*** 0.28 0.31 0.35 %
Meas. error Spec. Vol. at req. Flow nom.*** 0.28 0.31 0.35 %
Meas. error Spec. Vol. at req. Flow max.*** 0.28 0.31 0.35 %
Reynolds No. 1 283 508 1 064 582 910 758
Warnings / Messages
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The
results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

 
Print date: 26.08.2015 07:13 PM -8/8-
Applicator®: 10.21.00 / 149
Endress+Hauser Flowtec AG, Kägenstrasse 7, CH - 4153 Reinach BL 1, Contact
SWITZERLAND
Josua Ritter
To whom it may concern MTI
Phone +41617156508
josua.ritter@flowtec.endress.com

Reinach, 6 October 2015

Used standards - Tropical conditions:

We confirm that our equipment Proline Promag 400 has been tested for installations in tropical
conditions. The test results were positive, we confirm that this equipment is suitable for installations in
tropical conditions.

The following tests have been positively completed:

Test Intensity
Cold: -10°C, 16 hours
IEC 60068-2-1:2007 -20°C, 16 hours
-25°C, 16 hours
-40°C, 16 hours
Dry heat: 40°C, 16 hours
IEC 60068-2-2:2007 50°C, 16 hours
60°C, 16 hours
70°C, 16 hours
Change of temperature: -40°C/60°C, 5 cycles
IEC 60068-2-14:2009 -40°C/70°C, 2 cycles
Damp heat, steady state: 40°C, 95% RH, 48 hours
IEC 60068-2-78:2009
Damp heat, cyclic: 25°C/55°C, 96%RH,
IEC 60068-2-30:2009 2 cycles of 24 hours
Composite temperature/ 25°C/65°C, 5 cycles,
humidity cyclic test: 25°C/65°C/-10°C, 5 cycles
IEC 60068-2-38:1999 90%RH

Endress+Hauser Flowtec AG Phone +41 61 715 61 11


Kägenstrasse 7 Fax +41 61 711 09 89
CH - 4153 Reinach BL 1 www.endress.com
SWITZERLAND 1/2
Test set u
up

Climatic chamberr
Temperatuure range : -40 … 80°C
Humidity rrange : 0 ...9
98%

Testing rrig with master


m
Temperatu ure range : -40 … 120°CC
Pressure ra
ange : 0 … 10bar
1
Flow rangee : 0 … 3l/s
Medium : GGlysantin G4 48 + water, freezing pooint -21°C
Master : Prromass 83F, DN50
Current ou
utput masterr: 4mA = -0.5kg/s, 20m mA = 0.5kg//s
Time consttant : 1s

Data logg
ger
Type : Memmograph
Group1 : Reecording ma aximum vallues
Sample ratte group 1 : 1 minute
Group2 : reecording acttual values
Sample ratte group 2 : 15 seconds

Overview
w
The recordder records ambient
a tem
mperature (p pt1000) and d relative
humidity, mmeasured fllow from on ne or more DDUTS, measured flow
from the mmaster and medium
m mperature ass measured by the
tem
master. Thhe DUT is plaaced inside the climaticc chamber; the
t master
is located o
outside the climatic
c cha
amber. Coolling is done by a
secondary circuit usingg a cooling unit.
u Heatin
ng is done byy the
heating eleement in thee flow circuit. The heatting and thee cooling
are switcheed on and off over digittal outputs ccontrolled by
b the
climatic ch
hamber. Thee cooling is connected
c too digital outtput 1, the
heating to digital outp
put 2.

Kind regards

Josua Ritter
Head of Deepartment Product
P Man
nagement E
Electromagn
netic Flowmeters

2/2
Larsen & Toubro Limited, Construction.
PB No 979,Mount-Poonamallee Road,Manapakkam,Chennai-600089,Tamilnadu,India

CIN - L99999MH1946PLC004768

SCM Purchase Order - E9734PO5000103 - Project and Domestic - Dt.20-Apr-2015

Job : LE130517 - WS - 15 NOS LIS IN CLUSTER XV MR Number : E9734EMR5000135 DT: 07-Apr-2015


@BOLNGIR SUBRNAPUR BOUDH
:
LST Reg No : 21031104812 CST Reg No BHC-II-4680DT07-01-2003
Our Ref : E9734OFR5000115 DT: 18-Apr-2015 Your Ref : E9734OFR5000115/1 DT: 19-Apr-2015
Vendor : VQE00024 - ENDRESS + HAUSER (I) PVT. LTD., ( CHENNAI )
NEWNO.397(OLDNO281)ANNASALAI,, PRECISIONPLAZA,3RDFLOOR, , CHENNAI, TAMILNADU, INDIA, 600018.,
MR.ALOKKAPUR, MR.S.SURESH, 044-24322848, 044-24349213, balaji.poludassu@in.endress.com, AAACE5283C
Delivery : 3715 - 15 NOS LIS IN CLUSTER XV @BOLNGIR SUBRNAPUR BOUDH
Warehouse LARSEN&TOUBROLIMITED,CONSTRUCTION, 1stFLOOR,PRASANTIVIHAR,NEARGRIDCO,, SHONPUR,WDNO-2,DIST-
SHONPUR , SHONPUR , ORISSA, INDIA
Delivery : 01-May-2015 To 31-Jul-2015 LD Clause : Yes Price Variation : No
Period From

Delivery Term : AT OUR SITE STORES Payment : Shared Service Centre - Accounting Center
Centre

Created By : BARATHWAJ S DT: 20-Apr-2015 Auth By : SAMPATH A DT:20-Apr-2015

Remarks : Manufacturing, Supply, Inspection, Testing and Delivery of Electromagnetic Flow Meters as per client specifications.
Prices are FOR at site. The PO price includes basic price, taxes & duties as applicable and transportation up to site.
Prices mentioned in the Purchase order are on FIRM basis, no escalation what so ever will be applicable. ED is
exempted against notification 3/2004. CST at 2.00 percent is included in the PO Value. Delivery to be completed
within 12 weeks from the date of drawing approvals.
Payment : Stage -1. 90.00% After the Receipt of Materials within 90 Days by Cheque
Terms
Stage -2. 10.00% After the Submission of Performance BG within 0 Days by Cheque - PBG equivalent to 10 percent of
the PO value valid for 24 months from the date of last supply

Material Details Values In : INR

Sl.N Material Amd No UOM Quantity Basic Rate Net Rate Amount
o

1 772809ACY 0 Nos 5.00


full bore electromagnetic
flow meter (700 mm line
size )
2 772809ACZ 0 Nos 7.00
full bore electromagnetic
flow meter (900 mm line
size )
3 772809ADA 0 Nos 3.00
full bore electromagnetic
flow meter (1000 mm line
size )
Total Items : 3 PO Net Value :

Material Wise Tax Breakup

Material Description Tax Rate Components Tax % Value

772809ACY - full bore electromagnetic flow Sales Tax - Central Sale tax with Form-C - CST 2.00
meter (700 mm line size ) DIRECT SALE AGAINST C FORMS @ 2%
772809ACZ - full bore electromagnetic flow Sales Tax - Central Sale tax with Form-C - CST 2.00
meter (900 mm line size ) DIRECT SALE AGAINST C FORMS @ 2%
772809ADA - full bore electromagnetic flow Sales Tax - Central Sale tax with Form-C - CST 2.00
meter (1000 mm line size ) DIRECT SALE AGAINST C FORMS @ 2%

Report Generated at 20-Apr-2015 11:00:42 AM Page 1 (,3‹/ 7&RQVWUXFWLRQ$OOULJKWVUHVHUYHG


Larsen & Toubro Limited, Construction.
PB No 979,Mount-Poonamallee Road,Manapakkam,Chennai-600089,Tamilnadu,India

CIN - L99999MH1946PLC004768

SCM Purchase Order - E9734PO5000103 - Project and Domestic - Dt.20-Apr-2015

Terms & Conditions


1. Any special conditions mentioned in the purchase order shall be read in conjunction with the general purchase conditions
and all other documents forming part of this contract, where any portion of the general purchase conditions is repugnant to
or at variance with any provisions of the special conditions, the special purchase conditions shall prevail to the extent.
2. The seller shall acknowledge the receipt of the purchase order within seven days from the date of this order and shall
thereby confirm his acceptance of this purchase order in its entirety without exception. With seller's acceptance of
provisions of this purchase order, he waves and considers as cancelled any of his general sales conditions.

3. The terms and conditions of this purchase order constitute the entire agreement between the parties hereto. Changes if
any, will be binding only if the same are made in writing and signed by the authorized representatives of both the Buyer
and Seller.

4. DELIVERY TERMS:
a. Delivery Date: Time of delivery as mentioned in the purchase order, shall be the essence of the contract and no variation
shall be permitted, except with prior authorization in writing from the buyer.
b. Place of delivery: The goods shall be delivered/dispatched strictly as per the instructions in the purchase order.
c. Delayed Delivery: The time and date of the delivery as stipulated in the order shall be deemed to be the essence of the
contract in the case of delay in execution of the order beyond the date of delivery as stipulated in the order or beyond any
extension in writing sanctioned by the buyer the buyer shall at his option either:
i. Accept delayed deliveries at a price reduced by a sum/percentage mentioned in the purchase order for every week of
delay or part thereof.
ii. Cancel the order in part or in full and purchase such cancelled quantities from elsewhere on account of and at the risk of
the seller without prejudice to his rights under (i) above in respect of goods delivered.
d. Delays due to "force majeure"; In the event of causes of 'force majeure' occurring within the agreed delivery terms, the
delivery date may be extended by the buyer at this option on receipt of application from the seller without imposition of
liquidated damages. Only those causes which depend on natural calamities, civil wars and national strikes which have a
duration of more than seven consecutive calendar days are considered as the causes of ' force majeure'. The seller must
advise the buyer, by a registered letter duly certified by the Local Chamber of Commerce on Statutory Authorities, the
beginning and the end of the cause/s of delay immediately, but in no case later than 10 days from the beginning and end
of each cause of "force majeure" as defined above.
e. The goods shall correspond with the description or the samples or the original specification thereof in full detail and must
be delivered and dispatched within the stipulated time, as the case may be, otherwise the same shall be liable to be
rejected and the seller shall be deemed to have wrongfully neglected to deliver the goods according to the contract. The
buyer shall in that event, at his discretion, be entitled to either purchase such goods from other sources on seller's account
after due notice to seller in which case the seller shall be liable to pay to the buyer difference between the price at which
such goods have been purchased and the price calculated at the rate set out in this order or to hold the seller liable to pay
the buyer damages for non-delivery of goods for such wrongful negligence. Packing: Goods supplied against this order
must be suitable and properly packed. (Conforming to special condition stipulated by the buyer, if any) for safe and/or
undamaged transport by road or rail.

5. EXAMINATION OF GOODS : Irrespective of the fact that the goods are delivered to the buyer by the seller's place or at
buyer's said office or are dispatched as per buyer's instructions, by rail or by road, the goods shall always be supplied,
subject to detailed inspection at the buyer's said office or such other destination as specified in the order for ascertaining
whether the goods are in conformity with the contract or not and until then the buyer shall be deemed to have not
accepted such goods and upon any rejection of goods in question, the seller shall be deemed to have failed to deliver the
concerned goods in accordance with the contract.

6. REJECTION/REMOVAL OF REJECTED GOODS AND REPLACEMENT: Within 15 days from the receipt of the intimation from
the buyer of his rejection to accept the goods, the seller shall remove at his own cost the rejected goods from the buyer's
office or wherever such goods are lying. The buyer shall not be in any way responsible for or be held liable for any loss or
deterioration of the rejected goods whatsoever and such goods shall be entirely at the seller's risk. The seller shall pay to
the buyer reasonable storage charges for storing such rejected goods for a period exceeding 15 days as aforesaid.

7. BILLS & INVOICES: All bills/invoices for supplies made bearing sales tax registration number of the seller, should be
marked to the Accountant, Larsen & Toubro Limited of the place from where purchase order originates in triplicate, duly
endorsed with Purchase Order Reference Number and be Date invariably accompanied by advice of dispatch, detailed
packing list and
should also be accompanied by an appropriate certificate necessary under the sales-tax legislation. Such bills/invoices will
be paid for by the buyer within number of weeks of receipt thereof as mentioned in the purchase order, unless otherwise a
different period is agreed and incorporated in the purchase order. The seller must follow the billing instructions carefully to
enables settlement of your dues, Disregard of the same may involve delay in such settlement. The Seller must ensure the
following information in their bills: (1) Vendor Code Number (2) Purchase Order Item, Number, (3) Materials Code if any,
which information will be available in the Purchase Orders.

8. WARRANTY: The seller warrants that all materials and/or workmanship shall be of first class quality and standard and

Report Generated at 20-Apr-2015 11:00:42 AM Page 2 (,3‹/ 7&RQVWUXFWLRQ$OOULJKWVUHVHUYHG


Larsen & Toubro Limited, Construction.
PB No 979,Mount-Poonamallee Road,Manapakkam,Chennai-600089,Tamilnadu,India

CIN - L99999MH1946PLC004768

SCM Purchase Order - E9734PO5000103 - Project and Domestic - Dt.20-Apr-2015

the material supplied under this purchase order shall be suitable for the purpose for which the same is intended to be used.
The seller shall guarantee that the material shall be in strict compliance with the specification and requirements agreed
upon and
further agrees that all materials/goods shall be repaired or replaced as the case may be at his own expense, in case the
same have been found to the defective in respect of materials, workmanship, design of process of manufacturing, within a
period of twelve months after the same have been put in to use or 18 months from the date of acceptance of the goods by
the
buyer, whichever is earlier.

9. RIGHTS OF THE BUYER TO SET OFF: The buyer shall be entitled to recover from the seller any sum/s due to the buyer
on account of any damage/s or otherwise, whether in respect of supplies under this order or under any of the their
previous purchase orders, by deducing such sums from the amount due by them to the seller in respect of supplies made
under this order or any of their prior or subsequent order.

10. CANCELLATION: The buyer reserves his right to cancel this purchase order or any part
thereof and shall be entitled to rescind the contract wholly or in part after a written notice to the seller if (i) the seller fails
to supply in accordance with the terms of the purchase orders, (ii) any legal proceedings initiated against the Seller for
liquidation or bankruptcy, (iii) the seller fails to deliver the goods on time and/or replace the rejected goods promptly, (iv)
the seller makes general assignment for the benefit of the creditors, (v) Receivers appointed in respect of property of the
seller. The buyer shall also be entitled to cancel this order without assigning any reason/s or becoming in any way liable for
such cancellation, provided that in such event, the buyer shall accept the goods already manufactured in accordance with
this order and pay for the same.

11. NON-WAIVER: Failure of the buyer to insist upon any of the terms or conditions incorporated in the purchase order or
failure or delay to exercise any rights of remedies herein or by law, or failure to properly notify the seller in the event of
breach of, acceptance of, or payment for, any goods hereunder or approval of design, shall not release the seller and shall
not be deemed a waiver of any right of the buyer to insist upon the strict performance thereof or of any of his or their
rights or remedies as to any goods, regardless of when goods are dispatched, received or accepted.

12. CONTRACTUAL OBLIGATION: The product/parts covered by this order shall be manufactured by the seller to the
buyer's drawings and specifications. These drawings and specification are buyer's exclusive use and ownership, which the
seller shall have no right to dispute on any grounds whatsoever. It shall be obligatory on the seller's part not to divulge or
cause to divulge the process, details of manufacture or caused to be manufactured or enter into any direct or indirect sales
of these products/parts nor solicit or entertain any enquires for these products/parts by the seller or through others at any
time hereafter. Any enquiry received by the seller for these products/parts, howsoever, should be sent to the buyer
forthwith. The seller's failure to carry out his obligations herein shall mean breach of contract which shall entitle the buyer
at any time to take steps to prevent the seller from continuing the breach and also to claim damages for such breach.

13. NO ASSIGNMENT: This purchase Order shall not be assigned to any other agency by the seller without obtaining prior
written consent of the buyer.

14. The Parties represent and warrant to one another that at all times during the subsistence of this agreement the parties
are independent contractors. At no point of time the seller shall represent to any third party that they are the sole supplier
to the buyer or the agent of the buyer and further shall not enter in to any contract with any third party on that basis.
Without limiting the foregoing the seller agrees that it will not during or after the term of this agreement represent to any
person that they act for on behalf of the buyer or make use of seller¶s name or advertise their relationship with the seller
without seller¶s express written consent in each instance.

15. Severability: In the event of one or more provisions of this agreement shall, for any reason, be held by any court of
appropriate jurisdiction to be invalid, voidable or unenforceable in any respect such holding shall not affect any other
provision of this agreement.

16. Dispute Resolution: All disputes and differences arising out of or in connection with this agreement shall in the first
instance be settled amicably by mutual negotiation between the authorized representatives of both the parties herein
failing which the said disputes and differences shall be referred to arbitration by Sole arbitrator to be appointed by the
buyer herein. The arbitration shall be conducted in accordance with the Arbitration and conciliation Act, 1996 and/or any
statutory modifications thereof. The venue of such arbitration shall be Chennai and the award passed by the tribunal shall
be final and finding on the parties.

17. JURISDICTION: All disputes relating to this agreement shall be subject to the Court of competent jurisdiction situated
within the limits of Chennai.
18. CENTRAL SALES TAX 'C' FORM: A single 'C' Form will be issued by our appropriate Regional Office cumulatively for all
supplies effected by you up to the end of Asstt. Period i.e. 31st March OR on completion of entire supplies against any
Purchase Order unless the Order is likely to be placed again.

19. This portal is governed by the Terms & Conditions laid in the IT Act, 2000 & the
Report Generated at 20-Apr-2015 11:00:42 AM Page 3 (,3‹/ 7&RQVWUXFWLRQ$OOULJKWVUHVHUYHG
Larsen & Toubro Limited, Construction.
PB No 979,Mount-Poonamallee Road,Manapakkam,Chennai-600089,Tamilnadu,India

CIN - L99999MH1946PLC004768

SCM Purchase Order - E9734PO5000103 - Project and Domestic - Dt.20-Apr-2015

Copyright Act, 1957, The Indian Contract Act, 1872 and/or other applicable laws of India and users are automatically
agreeing to abide by all Terms & Conditions of the act. Any unauthorized usage of this portal is a legal offence.

Report Generated at 20-Apr-2015 11:00:42 AM Page 4 (,3‹/ 7&RQVWUXFWLRQ$OOULJKWVUHVHUYHG


TI01045D/06/EN/05.15 Products Solutions Services
71280401

Technical Information
Proline Promag L 400
Electromagnetic flowmeter

The flowmeter with an integrated web server and weight-optimized sensor


Application Your benefits
• The measuring principle is practically independent of • Reduced installation costs – flexible mounting by one‐of‐a‐
pressure, density, temperature and viscosity kind lap‐joint flange concept (DN < 350/14")
• Perfectly suitable for standard applications in the water and • Energy-saving flow measurement – no pressure loss due to
wastewater industry cross-section constriction
Device properties • Maintenance-free – no moving parts
• Up to 30 % less sensor weight • Safe operation – no need to open device thanks to touch
• Nominal diameter: DN 25 to 2400 (1 to 90") control display, backlighting
• Maximum reduced installation length to DVGW/ISO • Time‐saving local operation without additional software and
• Transmitter housing made of durable polycarbonate or hardware – integrated web server
aluminum • Integrated verification – Heartbeat Technology™
• Same housing concept for compact/remote version
• Integrated data logger for measured values monitoring
Proline Promag L 400

Table of contents

Document information . . . . . . . . . . . . . . . . . . . . . . . 4 Mechanical load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38


Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 38

Function and system design . . . . . . . . . . . . . . . . . . . 4 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38


Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Medium temperature range . . . . . . . . . . . . . . . . . . . . . . 38
Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pressure-temperature ratings . . . . . . . . . . . . . . . . . . . . 38
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pressure tightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Flow limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Vibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Mechanical construction . . . . . . . . . . . . . . . . . . . . 42
Dimensions in SI units . . . . . . . . . . . . . . . . . . . . . . . . . 42
Dimensions in US units . . . . . . . . . . . . . . . . . . . . . . . . . 53
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Measuring tube specification . . . . . . . . . . . . . . . . . . . . . 70
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Low flow cut off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fitted electrodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Surface roughness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Pin assignment, device plug . . . . . . . . . . . . . . . . . . . . . . 22
Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Service interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Certificates and approvals . . . . . . . . . . . . . . . . . . . 79
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . 27 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 C-Tick symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Drinking water approval . . . . . . . . . . . . . . . . . . . . . . . . 80
Certification PROFIBUS . . . . . . . . . . . . . . . . . . . . . . . . . 80
Modbus RS485 certification . . . . . . . . . . . . . . . . . . . . . 80
Performance characteristics . . . . . . . . . . . . . . . . . . 31
EtherNet/IP certification . . . . . . . . . . . . . . . . . . . . . . . . 80
Reference operating conditions . . . . . . . . . . . . . . . . . . . 31
Other standards and guidelines . . . . . . . . . . . . . . . . . . . 80
Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . 31
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Influence of ambient temperature . . . . . . . . . . . . . . . . . 32 Ordering information . . . . . . . . . . . . . . . . . . . . . . . 81
Product generation index . . . . . . . . . . . . . . . . . . . . . . . 81
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Application packages . . . . . . . . . . . . . . . . . . . . . . . 81
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Diagnostics functions . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Heartbeat Technology . . . . . . . . . . . . . . . . . . . . . . . . . 82
Length of connecting cable . . . . . . . . . . . . . . . . . . . . . . 35
Installing the wall-mount housing . . . . . . . . . . . . . . . . . 36 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Special mounting instructions . . . . . . . . . . . . . . . . . . . . 36 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 82
Communication-specific accessories . . . . . . . . . . . . . . . . 82
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . 83
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 37 System components . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Atmosphere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 84
Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Supplementary device-dependent documentation . . . . . . . 84
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

2 Endress+Hauser
Proline Promag L 400

Registered trademarks . . . . . . . . . . . . . . . . . . . . . . 84

Endress+Hauser 3
Proline Promag L 400

Document information
Symbols used Electrical symbols

Symbol Meaning Symbol Meaning

Direct current Alternating current

Direct current and alternating current Ground connection


A grounded terminal which, as far as
the operator is concerned, is
grounded via a grounding system.

Protective ground connection Equipotential connection


A terminal which must be connected A connection that has to be connected
to ground prior to establishing any to the plant grounding system: This
other connections. may be a potential equalization line
or a star grounding system depending
on national or company codes of
practice.

Symbols for certain types of information

Symbol Meaning

Permitted
Procedures, processes or actions that are permitted.

Preferred
Procedures, processes or actions that are preferred.

Forbidden
Procedures, processes or actions that are forbidden.

Tip
Indicates additional information.

Reference to documentation

Reference to page

Reference to graphic

Visual inspection

Symbols in graphics

Symbol Meaning Symbol Meaning

1, 2, 3,... Item numbers , , … Series of steps

A, B, C, ... Views A-A, B-B, C-C, ... Sections

Hazardous area Safe area (non-hazardous area)


- .
Flow direction

Function and system design


Measuring principle Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a
magnetic field.

4 Endress+Hauser
Proline Promag L 400

Ue
I

A0017035

Ue Induced voltage
B Magnetic induction (magnetic field)
L Electrode spacing
I Current
v Flow velocity

In the electromagnetic measuring principle, the flowing medium is the moving conductor. The
voltage induced (Ue) is proportional to the flow velocity (v) and is supplied to the amplifier by means
of two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DC
magnetic field is created through a switched direct current of alternating polarity.
Formulae for calculation
• Induced voltage Ue = B · L · v
• Volume flow  Q = A · v

Endress+Hauser 5
Proline Promag L 400

Measuring system The device consists of a transmitter and a sensor.


Two device versions are available:
• Compact version - transmitter and sensor form a mechanical unit.
• Remote version - transmitter and sensor are mounted in separate locations.

Transmitter

Promag 400 Device versions and materials


• Compact version: compact housing
– Polycarbonate plastic
– Aluminum, AlSi10Mg, coated
• Remote version: wall-mount housing
– Polycarbonate plastic
– Aluminum, AlSi10Mg, coated
Configuration:
A0017117
• External operation via four-line, illuminated local display with touch
control and guided menus ("Make-it-run" wizards) for applications
• Via operating tools (e.g. FieldCare)
• Via Web browser (e.g. Microsoft Internet Explorer)
• Also for device version with EtherNet/IP output:
– Via Add-on Profile Level 3 for automation system from Rockwell
Automation
– Via Electronic Data Sheet (EDS)
• Also for device version with PROFIBUS DP output:
Via PDM driver for Siemens automation system

Sensor

Promag L • Nominal diameter range: DN 25 to 2400 (1 to 90")


• Materials:
Lap joint flange, lap joint flange, – Sensor housing: aluminum, AlSi10Mg, coated; carbon steel with
stamped plate: DN 25 to 300 (1 to protective varnish
12") – Sensor connection housing: aluminum, AlSi10Mg, coated
– Measuring tubes:
DN 25 to 300 (1 to 12"): stainless steel, 1.4301/1.4306/304L
DN 350 to 1200 (14 to 48"): stainless steel,
1.4301/1.4307/202/304
DN 1350 to 2400 (54 to 90"): stainless steel, 1.4301/1.4307
– Liner: hard rubber, polyurethane, PTFE
– Electrodes: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS
A0017040 N06022)
– Process connections:
Fixed flange: DN 350 to 2400 (14 Stainless steel, 1.4301/1.4306/1.4404//1.4571/F316L
to 90") Carbon steel, A105/A181/A515(70)/FE410WB/P250GH/P235
GH/P265GH/S235JRG2/S235JR+N/S275JR
– Seals: as per DIN EN 1514-1
– Ground disks: stainless steel, 1.4435 (316L); Alloy C22, 2.4602
(UNS N06022)

A0017041

6 Endress+Hauser
Proline Promag L 400

Equipment architecture

1 2 3 4

5
A0021560

1 Possibilities for integrating measuring devices into a system


1 Control system (e.g. PLC)
2 EtherNet/IP
3 PROFIBUS DP
4 Modbus RS485
5 4-20 mA HART, pulse/frequency/switch output
6 Non-hazardous area
7 Non-hazardous area and Zone 2/Div. 2

Safety IT security
We only provide a warranty if the device is installed and used as described in the Operating
Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
changes to the device settings.
IT security measures in line with operators' security standards and designed to provide additional
protection for the device and device data transfer must be implemented by the operators themselves.

Input
Measured variable Direct measured variables
• Volume flow (proportional to induced voltage)
• Electrical conductivity

Calculated measured variables


Mass flow

Measuring range Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy
Electrical conductivity: 5 to 10 000 µS/cm

Flow characteristic values in SI units


Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[mm] [in] [m3/h] [m3/h] [m3] [m3/h]

25 1 9 to 300 dm3/min 75 dm3/min 0.5 dm3 1 dm3/min

32 – 15 to 500 dm3/min 125 dm3/min 1.0 dm3 2 dm3/min

40 1½ 25 to 700 dm3/min 200 dm3/min 1.5 dm3 3 dm3/min

Endress+Hauser 7
Proline Promag L 400

Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[mm] [in] [m3/h] [m3/h] [m3] [m3/h]

50 2 35 to 1 100 dm3/min 300 dm3/min 2.5 dm3 5 dm3/min

65 – 60 to 2 000 dm3/min 500 dm3/min 5 dm3 8 dm3/min

80 3 90 to 3 000 dm3/min 750 dm3/min 5 dm3 12 dm3/min

100 4 145 to 4 700 dm3/min 1 200 dm3/min 10 dm3 20 dm3/min

125 – 220 to 7 500 dm3/min 1 850 dm3/min 15 dm3 30 dm3/min

150 6 20 to 600 150 0.025 2.5

200 8 35 to 1 100 300 0.05 5

250 10 55 to 1 700 500 0.05 7.5

300 12 80 to 2 400 750 0.1 10

350 14 110 to 3 300 1 000 0.1 15

375 15 140 to 4 200 1 200 0.15 20

400 16 140 to 4 200 1 200 0.15 20

450 18 180 to 5 400 1 500 0.25 25

500 20 220 to 6 600 2 000 0.25 30

600 24 310 to 9 600 2 500 0.3 40

700 28 420 to 13 500 3 500 0.5 50

750 30 480 to 15 000 4 000 0.5 60

800 32 550 to 18 000 4 500 0.75 75

900 36 690 to 22 500 6 000 0.75 100

1 000 40 850 to 28 000 7 000 1 125

– 42 950 to 30 000 8 000 1 125

1 200 48 1 250 to 40 000 10 000 1.5 150

– 54 1 550 to 50 000 13 000 1.5 200

1 400 – 1 700 to 55 000 14 000 2 225

– 60 1 950 to 60 000 16 000 2 250

1 600 – 2 200 to 70 000 18 000 2.5 300

– 66 2 500 to 80 000 20 500 2.5 325

1 800 72 2 850 to 90 000 23 000 3 350

– 78 3 300 to 100 000 28 500 3.5 450

2 000 – 3 400 to 110 000 28 500 3.5 450

– 84 3 700 to 125 000 31 000 4.5 500

2 200 – 4 100 to 136 000 34 000 4.5 540

– 90 4 300 to 143 000 36 000 5 570

2 400 – 4 800 to 162 000 40 000 5.5 650

8 Endress+Hauser
Proline Promag L 400

Flow characteristic values in US units


Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[in] [mm] [gal/min] [gal/min] [gal] [gal/min]

1 25 2.5 to 80 18 0.2 0.25

1½ 40 7 to 190 50 0.5 0.75

2 50 10 to 300 75 0.5 1.25

– 65 16 to 500 130 1 2

3 80 24 to 800 200 2 2.5

4 100 40 to 1 250 300 2 4

8 200 155 to 4 850 1 200 10 15

10 250 250 to 7 500 1 500 15 30

12 300 350 to 10 600 2 400 25 45

14 350 500 to 15 000 3 600 30 60

15 375 600 to 19 000 4 800 50 60

16 400 600 to 19 000 4 800 50 60

18 450 800 to 24 000 6 000 50 90

20 500 1 000 to 30 000 7 500 75 120

24 600 1 400 to 44 000 10 500 100 180

28 700 1 900 to 60 000 13 500 125 210

30 750 2 150 to 67 000 16 500 150 270

32 800 2 450 to 80 000 19 500 200 300

36 900 3 100 to 100 000 24 000 225 360

40 1 000 3 800 to 125 000 30 000 250 480

42 – 4 200 to 135 000 33 000 250 600

48 1 200 5 500 to 175 000 42 000 400 600

54 – 9 to 300 Mgal/d 75 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

– 1 400 10 to 340 Mgal/d 85 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

60 – 12 to 380 Mgal/d 95 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

– 1 600 13 to 450 Mgal/d 110 Mgal/d 0.0008 Mgal/d 1.7 Mgal/d

66 – 14 to 500 Mgal/d 120 Mgal/d 0.0008 Mgal/d 2.2 Mgal/d

72 1 800 16 to 570 Mgal/d 140 Mgal/d 0.0008 Mgal/d 2.6 Mgal/d

78 – 18 to 650 Mgal/d 175 Mgal/d 0.0010 Mgal/d 3.0 Mgal/d

– 2 000 20 to 700 Mgal/d 175 Mgal/d 0.0010 Mgal/d 2.9 Mgal/d

84 – 24 to 800 Mgal/d 190 Mgal/d 0.0011 Mgal/d 3.2 Mgal/d

– 2 200 26 to 870 Mgal/d 210 Mgal/d 0.0012 Mgal/d 3.4 Mgal/d

90 – 27 to 910 Mgal/d 220 Mgal/d 0.0013 Mgal/d 3.6 Mgal/d

– 2 400 31 to 1 030 Mgal/d 245 Mgal/d 0.0014 Mgal/d 4.1 Mgal/d

To calculate the measuring range, use the Applicator sizing tool →  83

Endress+Hauser 9
Proline Promag L 400

Recommended measuring range


"Flow limit" section →  41

Operable flow range Over 1000 : 1

Input signal External measured values


Various pressure transmitters and temperature measuring devices can be ordered from Endress
+Hauser: see "Accessories" section →  84
It is recommended to read in external measured values to calculate the following measured variables:
Corrected volume flow

HART protocol
The measured values are written from the automation system to the measuring device via the HART
protocol. The pressure transmitter must support the following protocol-specific functions:
• HART protocol
• Burst mode

Fieldbuses
The measured values can be written from the automation system to the measuring via:
• PROFIBUS DP
• Modbus RS485
• EtherNet/IP

Status input

Maximum input values • DC 30 V


• 6 mA

Response time Adjustable: 5 to 200 ms

Input signal level • Low signal: DC –3 to +5 V


• High signal: DC 12 to 30 V

Assignable functions • Off


• Reset totalizers 1-3 separately
• Reset all totalizers
• Flow override

Output
Output signal Current output

Current output Can be set as:


• 4-20 mA NAMUR
• 4-20 mA US
• 4-20 mA HART
• 0-20 mA

Maximum output values • DC 24 V (no flow)


• 22.5 mA

Load 0 to 700 Ω

Resolution 0.5 µA

Damping Adjustable: 0.07 to 999 s

Assignable measured • Volume flow


variables • Mass flow
• Flow velocity
• Conductivity
• Electronic temperature

10 Endress+Hauser
Proline Promag L 400

Pulse/frequency/switch output

Function • With the order code for "Output; Input", option H: output 2 can be set as a pulse
or frequency output
• With the order code for "Output; Input", option I: output 2 and 3 can be set as a
pulse, frequency or switch output

Version Passive, open collector

Maximum input values • DC 30 V


• 250 mA

Voltage drop For 25 mA: ≤ DC 2 V

Pulse output

Pulse width Adjustable: 0.05 to 2 000 ms

Maximum pulse rate 10 000 Impulse/s

Pulse value Adjustable

Assignable measured • Volume flow


variables • Mass flow

Frequency output

Output frequency Adjustable: 0 to 12 500 Hz

Damping Adjustable: 0 to 999 s

Pulse/pause ratio 1:1

Assignable measured • Volume flow


variables • Mass flow
• Conductivity
• Flow velocity
• Electronic temperature

Switch output

Switching behavior Binary, conductive or non-conductive

Switching delay Adjustable: 0 to 100 s

Number of switching Unlimited


cycles

Assignable functions • Off


• On
• Diagnostic behavior
• Limit value:
– Off
– Volume flow
– Mass flow
– Conductivity
– Flow velocity
– Totalizer 1-3
– Electronic temperature
• Flow direction monitoring
• Status
– Empty pipe detection
– Low flow cut off

PROFIBUS DP

Signal encoding NRZ code

Data transfer 9.6 kBaud…12 MBaud

Endress+Hauser 11
Proline Promag L 400

Modbus RS485

Physical interface In accordance with EIA/TIA-485-A standard

Terminating resistor Integrated, can be activated via DIP switch on the transmitter electronics module

EtherNet/IP

Standards In accordance with IEEE 802.3

Signal on alarm Depending on the interface, failure information is displayed as follows:

Current output

4-20 mA
Failure mode Selectable (as per NAMUR recommendation NE 43):
• Minimum value: 3.6 mA
• Maximum value: 22 mA
• Defined value: 3.59 to 22.5 mA
• Actual value
• Last valid value

0-20 mA
Failure mode Choose from:
• Maximum alarm: 22 mA
• Defined value: 0 to 22.5 mA

HART
Device diagnostics Device condition can be read out via HART Command 48

Pulse/frequency/switch output

Pulse output
Failure mode Choose from:
• Actual value
• No pulses

Frequency output
Failure mode Choose from:
• Actual value
• 0 Hz
• Defined value: 0 to 12 500 Hz

Switch output
Failure mode Choose from:
• Current status
• Open
• Closed

PROFIBUS DP

Status and alarm Diagnostics in accordance with PROFIBUS PA Profile 3.02


messages

12 Endress+Hauser
Proline Promag L 400

Modbus RS485

Failure mode Choose from:


• NaN value instead of current value
• Last valid value

EtherNet/IP

Device diagnostics Device condition can be read out in Input Assembly

Local display

Plain text display With information on cause and remedial measures

Backlight Red backlighting indicates a device error.

Status signal as per NAMUR recommendation NE 107

Operating tool
• Via digital communication:
– HART protocol
– PROFIBUS DP
– Modbus RS485
– EtherNet/IP
• Via service interface

Plain text display With information on cause and remedial measures

Additional information on remote operation →  76

Web browser

Plain text display With information on cause and remedial measures

Light emitting diodes (LED)

Status information Status indicated by various light emitting diodes


The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
• EtherNet/IP network available
• EtherNet/IP connection established

Low flow cut off The switch points for low flow cut off are user-selectable.

Galvanic isolation The following connections are galvanically isolated from each other:
• Inputs
• Outputs
• Power supply

Protocol-specific data HART

Manufacturer ID 0x11

Device type ID 0x67

Endress+Hauser 13
Proline Promag L 400

HART protocol revision 7

Device description files Information and files under:


(DTM, DD) www.endress.com

HART load Min. 250 Ω

Dynamic variables Read out the dynamic variables: HART command 3


The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
• Off
• Volume flow
• Mass flow
• Conductivity
• Flow velocity
• Electronic temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
• Volume flow
• Mass flow
• Conductivity
• Flow velocity
• Electronic temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3

Device variables Read out the device variables: HART command 9


The device variables are permanently assigned.
A maximum of 8 device variables can be transmitted:
• 0 = volume flow
• 1 = mass flow
• 2 = conductivity
• 3 = flow velocity
• 4 = electronic temperature
• 5 = totalizer 1
• 6 = totalizer 2
• 7 = totalizer 3

PROFIBUS DP

Manufacturer ID 0x11

Ident number 0x1562

Profile version 3.02

Device description files (GSD, Information and files under:


DTM, DD) • www.endress.com
• www.profibus.org

Output values Analog input 1 to 4


(from measuring device to • Mass flow
automation system) • Volume flow
• Flow velocity
• Conductivity
• Electronic temperature
Digital input 1 to 2
• Empty pipe detection
• Low flow cut off
• Verification status
Totalizer 1 to 3
• Mass flow
• Volume flow

14 Endress+Hauser
Proline Promag L 400

Input values Analog output 1 (fixed assignment)


(from automation system to External density
measuring device) Digital output 1 to 2 (fixed assignment)
• Digital output 1: switch positive zero return on/off
• Digital output 2: start verification
Totalizer 1 to 3
• Totalize
• Reset and hold
• Preset and hold
• Stop
• Operating mode configuration:
– Net flow total
– Forward flow total
– Reverse flow total

Supported functions • Identification & Maintenance


Simplest device identification on the part of the control system and
nameplate
• PROFIBUS upload/download
Reading and writing parameters is up to ten times faster with PROFIBUS
upload/download
• Condensed status
Simplest and self-explanatory diagnostic information by categorizing
diagnostic messages that occur

Configuration of the device • DIP switches on the I/O electronics module


address • Via operating tools (e.g. FieldCare)

Modbus RS485

Protocol Modbus Applications Protocol Specification V1.1

Device type Slave

Slave address range 1 to 247

Broadcast address range 0

Function codes • 03: Read holding register


• 04: Read input register
• 06: Write single registers
• 08: Diagnostics
• 16: Write multiple registers
• 23: Read/write multiple registers

Broadcast messages Supported by the following function codes:


• 06: Write single registers
• 16: Write multiple registers
• 23: Read/write multiple registers

Supported baud rate • 1 200 BAUD


• 2 400 BAUD
• 4 800 BAUD
• 9 600 BAUD
• 19 200 BAUD
• 38 400 BAUD
• 57 600 BAUD
• 115 200 BAUD

Data transfer mode • ASCII


• RTU

Data access Each device parameter can be accessed via Modbus RS485.

 For Modbus register information

Endress+Hauser 15
Proline Promag L 400

EtherNet/IP

Protocol • The CIP Networks Library Volume 1: Common Industrial Protocol


• The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP

Communication type • 10Base-T


• 100Base-TX

Device profile Generic device (product type: 0x2B)

Manufacturer ID 0x49E

Device type ID 0x1067

Baud rates Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection

Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs

Supported CIP connections Max. 3 connections

Explicit connections Max. 6 connections

I/O connections Max. 6 connections (scanner)

Configuration options for • DIP switches on the electronics module for IP addressing
measuring device • Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• Electronic Data Sheet (EDS) integrated in the measuring device

Configuration of the EtherNet • Speed: 10 MBit, 100 MBit, auto (factory setting)
interface • Duplex: half-duplex, full-duplex, auto (factory setting)

Configuration of the device • DIP switches on the electronics module for IP addressing (last octet)
address • DHCP
• Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)

Device Level Ring (DLR) No

Fix Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 56

T → O configuration: 0x64 32

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 56

T → O configuration: 0x64 32

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x64 32

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x64 32

16 Endress+Hauser
Proline Promag L 400

Input Assembly • Current device diagnostics


• Volume flow
• Mass flow
• Conductivity
• Totalizer 1
• Totalizer 2
• Totalizer 3

Configurable Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 56

T → O configuration: 0x65 88

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 56

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Configurable Input Assembly • Volume flow


• Mass flow
• Electronic temperature
• Conductivity
• Totalizer 1 to 3
• Flow velocity
• Volume flow unit
• Mass flow unit
• Temperature unit
• Conductivity unit
• Unit totalizer 1-3
• Flow velocity unit
• Verification result
• Verification status

 The range of options increases if the measuring device has one or


more application packages.

Fix Output

Output Assembly • Activation of reset totalizers 1-3


• Activation of reference density compensation
• Reset totalizers 1-3
• External density
• Density unit
• Activation verification
• Start verification

Endress+Hauser 17
Proline Promag L 400

Configuration

Configuration Assembly Only the most common configurations are listed below.
• Software write protection
• Mass flow unit
• Mass unit
• Volume flow unit
• Volume unit
• Density unit
• Conductivity
• Temperature unit
• Totalizer 1-3:
– Assignment
– Unit
– Operating mode
– Failure mode
• Alarm delay

Power supply
Terminal assignment Transmitter

0-20 mA/4-20 mA HART connection version with additional outputs and inputs
The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2 3

+ - + -
L+/L

L-/N

+ - + -

22 23 20 21

1 2 26 27 24 25

A0020424

1 Supply voltage
2 Output 1 (26/27) and output 2 (24/25)
3 Output 3 (22/23) and input 1 (20/21)

18 Endress+Hauser
Proline Promag L 400

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

Signal transmission 0-20 mA/4-20 mA HART with additional outputs and inputs
Order code for Terminal numbers
"Output" and
Output 1 Output 2 Output 3 Input
"Input"
26 (+) 27 (-) 24 (+) 25 (-) 22 (+) 23 (-) 20 (+) 21 (-)

Option H • 4-20 mA HART Pulse/frequency Switch output -


(active) output (passive)
• 0-20 mA (passive)
(active)

Option I • 4-20 mA HART Pulse/frequency/ Pulse/frequency/ Status input


(active) switch output switch output
• 0-20 mA (passive) (passive)
(active)

PROFIBUS DP connection version


The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2
L+/L

L-/N

B A

1 2 2627

A0020426

1 Supply voltage (wide range power unit)


2 PROFIBUS DP

Endress+Hauser 19
Proline Promag L 400

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

PROFIBUS DP signal transmission


Order code for "Output" and "Input" Terminal numbers

26 (RxD/TxD-P) 27 (RxD/TxD-N)

Option L B A

Order code for "Output":


Option L: PROFIBUS DP, for use in non-hazardous areas and Zone 2/div. 2

Modbus RS485 connection version


The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2
L+/L

L-/N

B A

1 2 2627

A0020427

1 Supply voltage (wide range power unit)


2 Modbus RS485

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

20 Endress+Hauser
Proline Promag L 400

Signal transmission Modbus RS485


Order code for "Output" and "Input" Terminal numbers

26 (+) 27 (-)

Option M B A

EtherNet/IP connection version


The sensor can be ordered with terminals or a device plug.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

Device plug Terminals • Option L: plug M12x1 + thread NPT ½"


• Option N: plug M12x1 + coupling M20
• Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

1 2
L+/L

L-/N

1 2

A0020428

1 Supply voltage (wide range power unit)


2 EtherNet/IP

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

EtherNet/IP signal transmission


Order code for "Output" Connection via

Option N EtherNet/IP connector

Endress+Hauser 21
Proline Promag L 400

Remote version

1 2

GND
E1
E2
S1

S2

E
S
A
6 5 7 8 4 37 36 42 41

1 n.c. n.c. n.c.


2
5 7 4 37 42 41

E1
E2
GND
E
B

A0020534

2 Remote version terminal assignment


A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable
n.c. Not connected, insulated cable shields

Terminal No. and cable colors: 6/5 = brown; 7/8 = white; 4 = green; 36/37 = yellow

Pin assignment, device plug Order codes for the M12x1 connectors, see the "Order code for electrical connection" column:
EtherNet/IP

EtherNet/IP

Device plug for signal transmission (device side)

2 Pin Assignment Coding Plug/socket

1 + Tx D Socket

2 + Rx
1 3
3 - Tx

4 - Rx
4
A0016812

 Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.

Supply voltage Transmitter

Order code for "Power supply" Terminal voltage Frequency range

AC100 to 240 V 50/ 60 Hz, ±4 Hz


Option L
AC/DC24 V 50/ 60 Hz, ±4 Hz

Power consumption Order code for "Output" Maximum power consumption

Option H: 4-20mA HART, pulse/frequency/switch


30 VA/8 W
output, switch output

Option I: 4-20mA HART, 2 x pulse/frequency/switch


30 VA/8 W
output, status input

22 Endress+Hauser
Proline Promag L 400

Order code for "Output" Maximum power consumption

Option L: PROFIBUS DP 30 VA/8 W

Option M: Modbus RS485 30 VA/8 W

Option N: EtherNet/IP 30 VA/8 W

Current consumption Transmitter

Order code for "Power supply" Maximum Maximum


Current consumption switch-on current

Option L: AC 100 to 240 V 145 mA 25 A (< 5 ms)

Option L: AC/DC 24 V 350 mA 27 A (< 5 ms)

Power supply failure • Totalizers stop at the last value measured.


• Configuration is retained in the plug-in memory (HistoROM DAT).
• Error messages (incl. total operated hours) are stored.

Electrical connection Connecting the transmitter

A B

1 2 2 1 2 2
A0017113

3 Supply voltage and signal transmission connection


A Compact version
B Remote version wall-mount housing
1 Cable entry for supply voltage
2 Cable entry for signal transmission

Remote version connection

Connecting cable

A B

1 2 1 2
A0017267

4 Connecting cable connection: electrode and coil current cable


A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable

• Fix the cable run or route it in an armored conduit.


Cable movements can influence the measuring signal especially in the case of low fluid
conductivities.
• Route the cable well clear of electrical machines and switching elements.
• Ensure potential equalization between sensor and transmitter .

Endress+Hauser 23
Proline Promag L 400

Connection examples

Current output 4-20 mA HART

1 2 3
4...20 mA
+ +
– 6
_

4 5
A0016800

5 Connection example for 4-20 mA HART current output (active)


1 Automation system with current input (e.g. PLC)
2 Cable shield, observe cable specifications →  29
3 Connection for HART operating devices
4 Resistor for HART communication (≥ 250 Ω): observe maximum load
5 Analog display unit: observe maximum load
6 Transmitter

Current output 4-20 mA

0/4...20 mA
+
+
– 3
_

2
A0017162

6 Connection example for 0-20 mA current output (active) and 4-20 mA current output (active)
1 Automation system with current input (e.g. PLC)
2 Analog display unit: observe maximum load
3 Transmitter

Pulse/frequency output

1 2
– +

_ +
– 3
+
12345
A0016801

7 Connection example for pulse/frequency output (passive)


1 Automation system with pulse/frequency input (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

24 Endress+Hauser
Proline Promag L 400

Switch output

1 2
_ +
_
+
_ 3
+

A0016802

8 Connection example for switch output (passive)


1 Automation system with switch input (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

PROFIBUS DP

1 2

A A
3
B
B

A
3
B

A0021429

9 Connection example for PROFIBUS DP, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  29
3 Transmitter

If baud rates > 1.5 MBaud an EMC cable entry must be used and the cable shield must continue
as far as the terminal wherever possible.

Endress+Hauser 25
Proline Promag L 400

Modbus RS485

1 2 3

A A
4
B
B

A
4
B

A0016803

 10 Connection example for Modbus RS485, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  29
3 Distribution box
4 Transmitter

EtherNet/IP

1 2 3 4

A0016805

 11 Connection example for EtherNet/IP


1 Control system (e.g. PLC)
2 Ethernet switch
3 Observe cable specifications →  30
4 Device plug
5 Transmitter

Status input

1 2
+ _
+
_
+ 3
_

A0017163

 12 Connection example for status input


1 Automation system with status output (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

26 Endress+Hauser
Proline Promag L 400

Potential equalization Requirements


Please consider the following to ensure correct measurement:
• Same electrical potential for the fluid and sensor
• Remote version: same electrical potential for the sensor and transmitter
• Company-internal grounding concepts
• Pipe material and grounding

Connection examples for standard situations

Metal, grounded pipe

A0016315

 13 Potential equalization via measuring tube

Connection example in special situations

Unlined and ungrounded metal pipe


This connection method also applies in situations where:
• The customary potential equalization is not used
• Equalizing currents are present

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

DN ≤ 300 DN ≥ 350

A0016317

 14 Potential equalization via ground terminal and pipe flanges

Note the following when installing:


• Connect both sensor flanges to the pipe flange via a ground cable and ground them.
• Connect the connection housing of the transmitter or sensor to ground potential by means of the
ground terminal provided for the purpose. To mount the ground cable:
– If DN ≤ 300 (12"): Mount the ground cable directly on the conductive flange coating of the
sensor with the flange screws.
– If DN ≥ 350 (14"): Mount the ground cable directly on the metal transport bracket.
For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The necessary ground cable can be ordered from Endress+Hauser .

Plastic pipe or pipe with insulating liner


This connection method also applies in situations where:
• The customary potential equalization is not used
• Equalizing currents are present

Endress+Hauser 27
Proline Promag L 400

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

A0016318

 15 Potential equalization via ground terminal and ground disks

Note the following when installing:


The ground disks must be connected to the ground terminal via the ground cable and be connected
to ground potential.
For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The ground cable and ground disks can be ordered from Endress+Hauser →  82.

Pipe with a cathodic protection unit


This connection method is only used if the following two conditions are met:
• Metal pipe without liner or pipe with electrically conductive liner
• Cathodic protection is integrated in the personal protection equipment

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

+

A0016319

Prerequisite: The sensor is installed in the pipe in a way that provides electrical insulation.
1. Connect the two flanges of the pipe to one another via a ground cable.
2. Guide the shield of the signal lines through a capacitor.
3. Connect the measuring device to the power supply such that it is floating in relation to the
protective ground (isolation transformer).

For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The necessary ground cable can be ordered from Endress+Hauser .

Terminals Transmitter
• Supply voltage cable: plug-in spring terminals for wire cross-sections
0.5 to 2.5 mm2 (20 to 14 AWG)
• Signal cable: plug-in spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
• Electrode cable: spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
• Coil current cable: spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
Sensor connection housing
Spring terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)

28 Endress+Hauser
Proline Promag L 400

Cable entries Cable entry thread


• M20 x 1.5
• Via adapter:
– NPT ½"
– G ½"
Cable gland
• For standard cable: M20 × 1.5 with cable 6 to 12 mm (0.24 to 0.47 in)
• For reinforced cable: M20 × 1.5 with cable 9.5 to 16 mm (0.37 to 0.63 in)
If metal cable entries are used, use a grounding plate.

Cable specification Permitted temperature range


• –40 °C (–40 °F) to +80 °C (+176 °F)
• Minimum requirement: cable temperature range ≥ ambient temperature +20 K

Power supply cable


Standard installation cable is sufficient.

Signal cable

Current output
• For 0-20 mA and 4-20 mA: standard installation cable is sufficient.
• For 4-20 mA HART: Shielded cable recommended. Observe grounding concept of the plant.

Pulse/frequency/switch output
Standard installation cable is sufficient.

Status input
Standard installation cable is sufficient.

PROFIBUS DP
The IEC 61158 standard specifies two types of cable (A and B) for the bus line which can be used for
every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance <30 pF/m

Wire cross-section >0.34 mm2 (22 AWG)

Cable type Twisted pairs

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

Modbus RS485
The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used
for every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance <30 pF/m

Wire cross-section >0.34 mm2 (22 AWG)

Cable type Twisted pairs

Endress+Hauser 29
Proline Promag L 400

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

EtherNet/IP
The standard ANSI/TIA/EIA-568-B.2 Annex specifies CAT 5 as the minimum category for a cable
used for EtherNet/IP. CAT 5e and CAT 6 are recommended.
For more information on planning and installing EtherNet/IP networks, please refer to the
"Media Planning and Installation Manual. EtherNet/IP" of ODVA Organization.

Connecting cable for remote version

Electrode cable

Standard cable 3 ×0.38 mm2 (20 AWG) with common, braided copper shield ( ~7 mm (0.28 in)
and individual shielded cores

Cable for empty pipe 4 ×0.38 mm2 (20 AWG) with common, braided copper shield ( ~7 mm (0.28 in)
detection (EPD) and individual shielded cores

Conductor resistance ≤50 Ω/km (0.015 Ω/ft)

Capacitance: core/shield ≤420 pF/m (128 pF/ft)

Operating temperature –20 to +80 °C (–68 to +176 °F)

Coil current cable

Standard cable 2 ×0.75 mm2 (18 AWG) with common, braided copper shield ( ~ 7 mm (0.28"))
and individually shielded cores

Conductor resistance ≤37 Ω/km (0.011 Ω/ft)

Capacitance: core/core, ≤120 pF/m (37 pF/ft)


shield grounded

Operating temperature –20 to +80 °C (–68 to +176 °F)

Test voltage for cable ≤ AC 1433 V r.m.s. 50/60 Hz or ≥ DC 2026 V


insulation

1
2
3
4
5
6
7
a b
A0003194

 16 Cable cross-section
a Electrode cable
b Coil current cable
1 Core
2 Core insulation
3 Core shield
4 Core jacket
5 Core reinforcement
6 Cable shield
7 Outer jacket

30 Endress+Hauser
Proline Promag L 400

Reinforced connecting cables


Reinforced connecting cables with an additional, reinforcing metal braid should be used for:
• When laying the cable directly in the ground
• Where there is a risk of damage from rodents
Reinforced connecting cables with an additional, reinforcing metal braid can be ordered from
Endress+Hauser .

Operation in zones of severe electrical interference


The measuring system meets the general safety requirements →  80 and EMC specifications
→  38.
Grounding is by means of the ground terminal provided for the purpose inside the connection
housing. The stripped and twisted lengths of cable shield to the ground terminal must be as short as
possible.

Performance characteristics
Reference operating In accordance with DIN EN 29104
conditions • Medium temperature: +28 ± 2 °C (+82 ± 4 °F)
• Ambient temperature: +22 ± 2 °C (+72 ± 4 °F)
• Warm-up period:30 min
Installation
• Inlet run > 10 × DN
• Outlet run > 5 × DN
• Sensor and transmitter grounded.
• The sensor is centered in the pipe.
To calculate the measuring range, use the Applicator sizing tool →  83

Maximum measured error Error limits under reference operating conditions


o.r. = of reading
Volume flow
• ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
• Optional: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Fluctuations in the supply voltage do not have any effect within the specified range.

[%]
2.5
2.0
0.5 %
1.5
0.2 %
1.0
0.5
0
0 1 2 4 6 8 10 [m/s]
v
0 5 10 15 20 25 30 32 [ft/s]
A0005531

 17 Maximum measured error in % o.r.

Electrical conductivity
Max. measured error not specified.

Endress+Hauser 31
Proline Promag L 400

Accuracy of outputs
o.r. = of reading
The outputs have the following base accuracy specifications.

Current output

Accuracy Max. ±5 µA

Pulse/frequency output

Accuracy Max. ±50 ppm o.r. (across the complete ambient temperature range)

Repeatability o.r. = of reading


Volume flow
max. ±0.1 % o.r. ± 0.5 mm/s (0.02 in/s)
Electrical conductivity
Max. ±5 % o.r.

Influence of ambient o.r. = of reading


temperature
Current output

Temperature coefficient Max. ±0.005% o.r./°C

Pulse/frequency output

Temperature coefficient No additional effect. Included in accuracy.

Installation
No special measures such as supports are necessary. External forces are absorbed by the construction
of the device.

Mounting location
h

A0023343

Preferably install the sensor in an ascending pipe, and ensure a sufficient distance to the next pipe
elbow: h ≥ 2 × DN
To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
the following mounting locations in the pipe:
• Highest point of a pipeline.
• Directly upstream of a free pipe outlet in a down pipe.

32 Endress+Hauser
Proline Promag L 400

Installation in down pipes


Install a siphon with a vent valve downstream of the sensor in down pipes whose length h ≥ 5 m
(16.4 ft). This precaution is to avoid low pressure and the consequent risk of damage to the
measuring tube. This measure also prevents the system losing prime.
For information on the liner's resistance to partial vacuum

1
2

h
A0017064

 18 Installation in a down pipe


1 Vent valve
2 Pipe siphon
h Length of down pipe

Installation in partially filled pipes


A partially filled pipe with a gradient necessitates a drain-type configuration. The empty pipe
detection (EPD) function offers additional protection by detecting empty or partially filled pipes.

N
×D
³2
N
×D
³5

A0017063

For heavy sensors DN ≥ 350 (14")

A0016276

Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
flow direction (direction of medium flow through the piping).
An optimum orientation position helps avoid gas and air accumulations and deposits in the
measuring tube.
The measuring device also offers the empty pipe detection function to detect partially filled
measuring pipes in the event of outgassing fluids or variable process pressures.

Endress+Hauser 33
Proline Promag L 400

Vertical

A0015591

Optimum for self-emptying pipe systems and for use in conjunction with empty pipe detection.

Horizontal

2 2

A0016260

1 EPD electrode for empty pipe detection


2 Measuring electrodes for signal detection
3 Reference electrode for potential equalization

• The measuring electrode plane must be horizontal. This prevents brief insulation of the two
measuring electrodes by entrained air bubbles.
• Empty pipe detection only works if the transmitter housing is pointing upwards as otherwise
there is no guarantee that the empty pipe detection function will actually respond to a
partially filled or empty measuring tube.

Inlet and outlet runs If possible, install the sensor upstream from fittings such as valves, T-pieces or elbows.
Observe the following inlet and outlet runs to comply with accuracy specifications:

≥ 5 × DN ≥ 2 × DN

A0016275

Adapters Suitable adapters to DIN EN 545 (double-flange reducers) can be used to install the sensor in larger-
diameter pipes. The resultant increase in the rate of flow improves measuring accuracy with very
slow-moving fluids.
The nomogram shown here can be used to calculate the pressure loss caused by reducers and
expanders:
• Calculate the ratio of the diameters d/D.
• From the nomogram read off the pressure loss as a function of flow velocity (downstream from
the reduction) and the d/D ratio.
The nomogram only applies to liquids with a viscosity similar to that of water.

34 Endress+Hauser
Proline Promag L 400

[mbar] 100

8 m/s
7 m/s

6 m/s
10
5 m/s

max. 8° 4 m/s

3 m/s
d D
2 m/s
1

1 m/s

d/D 0.5 0.6 0.7 0.8 0.9


A0016359

Length of connecting cable To ensure correct measuring results when using the remote version,
observe the maximum permitted cable length Lmax. This length is determined by the conductivity of
the fluid.
If measuring liquids in general: 5 µS/cm

[µS/cm]

200

100
L max

5 [m]
10 100 200 L max
[ft]
0 200 400 600

A0016539

 19 Permitted length of connecting cable for remote version


Area shaded gray = permitted range
Lmax= length of connecting cable in [m] ([ft])
[µS/cm] = fluid conductivity

Endress+Hauser 35
Proline Promag L 400

Installing the wall-mount Wall mounting


housing
17 (0.67) = =

14 (0.55)
5.8 (0.23)

210.5 (8.29)
5.8 (0.23)
149 (5.85)

A0020523

 20 Engineering unit mm (in)

Post mounting

ø 20…70 3x TX 25
(ø 0.79…2.75)

)
~ 4.0
02(
~1

4x SW 8

A0020705

 21 Engineering unit mm (in)

Special mounting Display protection


instructions
To ensure that the optional display protection can be easily opened, maintain the following
minimum head clearance: 350 mm (13.8 in)

36 Endress+Hauser
Proline Promag L 400

Environment
Ambient temperature range Transmitter –40 to +60 °C (–40 to +140 °F)

Local display –20 to +60 °C (–4 to +140 °F), the readability of the display may be
impaired at temperatures outside the temperature range.

Sensor • Process connection material, carbon steel:


–10 to +60 °C (+14 to +140 °F)
• Process connection material, stainless steel:
–40 to +60 °C (–40 to +140 °F)
Mount the transmitter separately from the sensor if both the ambient
and fluid temperatures are high.

Liner Do not exceed or fall below the permitted temperature range of the liner .

If operating outdoors:
• Install the measuring device in a shady location.
• Avoid direct sunlight, particularly in warm climatic regions.
• Avoid direct exposure to weather conditions.
• If the compact version of the device is insulated at low temperatures, the insulation must also
include the device neck.
• Protect the display against impact.
• Protect the display from abrasion by sand in desert areas.
A display protector can be ordered from Endress+Hauser: "Accessories" section →  82

Storage temperature The storage temperature corresponds to the operating temperature range of the measuring
transmitter and the appropriate measuring sensors.
• Protect the measuring device against direct sunlight during storage in order to avoid unacceptably
high surface temperatures.
• Select a storage location where moisture cannot collect in the measuring device as fungus or
bacteria infestation can damage the liner.
• If protection caps or protective covers are mounted these should never be removed before
installing the measuring device.

Atmosphere If a plastic transmitter housing is permanently exposed to certain steam and air mixtures, this can
damage the housing.
If you are unsure, please contact your Endress+Hauser Sales Center for clarification.

Degree of protection Transmitter


• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure
Sensor
• As standard: IP66/67, type 4X enclosure
• Optionally available for remote version:
IP68, type 6P enclosure (for DN ≤ 300 (12") only possible in conjunction with stainless steel
flanges)
Not suitable for use in corrosive atmospheres/liquids or in buried applications if special
precautions are not taken.

Shock resistance Compact version


6 ms 30 g, according to IEC 60068-2-27
Remote version
• Transmitter: 6 ms 30 g, according to IEC 60068-2-27
• Sensor: 6 ms 50 g, according to IEC 60068-2-27

Vibration resistance Compact version


• Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
• Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64

Endress+Hauser 37
Proline Promag L 400

Remote version
• Transmitter
– Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64
• Sensor:
– Vibration sinusoidal, 2 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 2.70 g rms, according to IEC 60068-2-64

Mechanical load • Protect the transmitter housing against mechanical effects, such as shock or impact; the use of the
remote version is sometimes preferable.
• Never use the transmitter housing as a ladder or climbing aid.

Electromagnetic • As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)


compatibility (EMC) • Complies with emission limits for industry as per EN 55011 (Class A)
• Device version with PROFIBUS DP: Complies with emission limits for industry as per EN 50170
Volume 2, IEC 61784
The following applies for PROFIBUS DP: If baud rates > 1.5 MBaud an EMC cable entry must be
used and the cable shield must continue as far as the terminal wherever possible.
For details refer to the Declaration of Conformity.

Process
Medium temperature range • 0 to +80 °C (+32 to +176 °F) for hard rubber, DN 350 to 2400 (14 to 90")
• –20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 1200 (1 to 48")
• –20 to +90 °C (–4 to +194 °F) for PTFE, DN 25 to 300 (1 to 12")

Conductivity ≥ 5 μS/cm for liquids in general


Note that in the case of the remote version, the requisite minimum conductivity also depends
on the cable length →  35.

Pressure-temperature The following pressure-temperature ratings refer to the entire device and not just the process
ratings connection.

Process connection: lap joint flange/lap joint flange, stamped plate according to EN 1092-1
(DIN 2501) and ASME B16.5; DN 25 to 300 (1 to 12")

[psi] [bar]
300 20
Lap joint PN 16 / Class 150
200 15
10
100 Lap joint flange, stamped plate PN 10
5 Lap joint PN 10

0 0
-60 -40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300 [°F]


A0021399-EN

 22 Process connection material: stainless steel (min. -40 °C (-40 °F)), carbon steel (min. -10 °C (+14 °F))

38 Endress+Hauser
Proline Promag L 400

Process connection: fixed flange according to EN 1092-1 (DIN 2501)

[psi] [bar]
300 20

200 15
PN 10
10
100
5 PN 6
0 0
-40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300 [°F]


A0021402-EN

 23 Process connection material: stainless steel, 1.4306/1.4404/1.4571/F316L; carbon steel, A105/


FE410WB/S235JRG2

Process connection: fixed flange according to ASME B16.5

[psi] [bar]
40
500
400 30
300 20
200 Class 150
10
100
0 0
-40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300 [°F]


A0021405-EN

 24 Process connection material: stainless steel, F316L similar to 1.4404; carbon steel, A105/A515(70)

Process connection: fixed flange according to AWWA C207

[psi] [bar]
160 11
145 10 Class D
130 9
116 8
0 0
-40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300 [°F]


A0021406-EN

 25 Process connection material: carbon steel, A105/A181/P265GH/S275JR

Endress+Hauser 39
Proline Promag L 400

Process connection: fixed flange according to AS 2129

[psi] [bar]

300 20

200 15
Table E
10
100
5
0 0
-40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300[°F]


A0021419-EN

 26 Process connection material: A105/FE410WB/P235GH/P265GH/S235JRG2

Process connection: fixed flange according to AS 4087

[psi] [bar]

300 20
PN 16
200 15
10
100
5
0 0
-40 -20 0 20 40 60 80 100120140 [°C]

-40 0 100 200 300[°F]


A0023065-EN

 27 Process connection material: A105/P265GH/S275JR

Pressure tightness Liner: hard rubber, polyurethane


Nominal diameter Liner Limit values for absolute pressure in [mbar] ([psi]) for fluid
temperatures:

[mm] [in] +25 °C (+77 °F) +50 °C (+122 °F) +80 °C (+176 °F)

350…2400 14…90 Hard rubber 0 (0) 0 (0) 0 (0)

25…1200 1…48 Polyurethane 0 (0) 0 (0) –

Liner: PTFE
Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:

[mm] [in] +25 °C (+77 °F) +90 °C (+194 °F)

25 1 0 (0) 0 (0)

40 2 0 (0) 0 (0)

50 2 0 (0) 0 (0)

65 2½ 0 (0) 40 (0.58)

80 3 0 (0) 40 (0.58)

100 4 0 (0) 135 (2.0)

125 5 135 (2.0) 240 (3.5)

150 6 135 (2.0) 240 (3.5)

200 8 200 (2.9) 290 (4.2)

40 Endress+Hauser
Proline Promag L 400

Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:

[mm] [in] +25 °C (+77 °F) +90 °C (+194 °F)

250 10 330 (4.8) 400 (5.8)

300 12 400 (5.8) 500 (7.3)

Flow limit The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The
optimum velocity of flow is between 2 to 3 m/s (6.56 to 9.84 ft/s). Also match the velocity of flow
(v) to the physical properties of the fluid:
• v < 2 m/s (6.56 ft/s): for abrasive fluids (e.g. potter's clay, lime milk, ore slurry)
• v > 2 m/s (6.56 ft/s): for fluids producing buildup (e.g. wastewater sludges)
A necessary increase in the flow velocity can be achieved by reducing the sensor nominal
diameter.
For an overview of the measuring range full scale values, see the "Measuring range" section
→ 7

Pressure loss • No pressure loss occurs if the sensor is installed in a pipe with the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545 →  34

System pressure

A0015594

Never install the sensor on the pump suction side in order to avoid the risk of low pressure, and thus
damage to the liner.
Furthermore, install pulse dampers if reciprocating, diaphragm or peristaltic pumps are used.

• For information on the liner's resistance to partial vacuum →  40


• For information on the shock resistance of the measuring system →  37
• For information on the vibration resistance of the measuring system →  37

Vibrations In the event of very strong vibrations, the pipe and sensor must be supported and fixed.
It is also advisable to mount the sensor and transmitter separately.
• For information on the shock resistance of the measuring system →  37
• For information on the vibration resistance of the measuring system →  37

L
A0016266

 28 Measures to avoid device vibrations (L > 10 m (33 ft))

Endress+Hauser 41
Proline Promag L 400

Mechanical construction
Dimensions in SI units Compact version

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated"

A D
B C

E
G
F
J
H K
A0020352

DN A B C D E F G H J K 1)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 193 103 90 167 222 84 306 120 94 200

32 193 103 90 167 222 84 306 120 94 200

40 193 103 90 167 222 84 306 120 94 200

50 193 103 90 167 222 84 306 120 94 200

65 193 103 90 167 247 109 356 180 94 200

80 193 103 90 167 247 109 356 180 94 200

100 193 103 90 167 247 109 356 180 94 250

125 193 103 90 167 287 150 437 260 140 250

150 193 103 90 167 287 150 437 260 140 300

200 193 103 90 167 312 180 492 324 156 350

250 193 103 90 167 337 205 542 400 166 450

300 193 103 90 167 362 230 592 460 166 500

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

42 Endress+Hauser
Proline Promag L 400

A D
B C

E
F
H

G J

A0017153

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 193 103 90 167 386 290 550

375 193 103 90 167 412 290 600

400 193 103 90 167 412 290 600

450 193 103 90 167 440 290 600

500 193 103 90 167 465 290 600

600 193 103 90 167 506 290 600

700 193 103 90 167 571 424 700

750 193 103 90 167 608 454 750

800 193 103 90 167 627 500 800

900 193 103 90 167 677 580 900

1000 193 103 90 167 727 660 1000

1050 193 103 90 167 763 755 1050

1200 193 103 90 167 841 828 1200

1350 193 103 90 167 953 1008 1350

1400 193 103 90 167 953 1008 1400

1500 193 103 90 167 1053 1147 1500

1600 193 103 90 167 1053 1147 1600

1650 193 103 90 167 1104 1284 1650

1800 193 103 90 167 1161 1379 1800

2000 193 103 90 167 1272 1569 2000

2150 193 103 90 167 1372 1711 2150

2200 193 103 90 167 1372 1711 2200

2300 193 103 90 167 1477 1859 2300

2400 193 103 90 167 1477 1859 2400

Endress+Hauser 43
Proline Promag L 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 631 638 702 653 648 490 505 520 533 525

375 – – – – 687 – – – – 550

400 682 694 760 710 702 540 565 580 597 580

450 737 747 823 757 760 595 615 640 635 640

500 787 800 926 814 817 645 670 715 699 705

600 883 896 1026 912 918 755 780 840 813 825

700 1001 1018 1145 1034 1026 860 895 910 927 910

750 – – – 1100 1106 – – – 984 995

800 1115 1135 1240 1157 1157 975 1015 1025 1060 1060

900 1215 1235 1240 1261 1265 1075 1115 1125 1168 1175

1000 1315 1342 1355 1372 1355 1175 1230 1225 1289 1255

1050 – – – 1436 – – – – 1346 –

1200 1544 1569 1584 1597 1586 1405 1455 1255 1511 1490

1350 – – – 1795 – – – – 1683 –

1400 1768 1791 1796 – – 1630 1675 1685 – –

1500 – – – 1980 – – – – 1854 –

1600 1968 2011 2019 – – 1830 1915 1930 – –

1650 – – – 2120 – – – – 2032 –

1800 2183 2218 2226 2259 – 2045 2115 2130 2197 –

2000 2404 2434 2444 2453 – 2265 2325 2345 2362 –

2150 – – – 2639 – – – – 2534 –

2200 2609 2647 – – – 2475 2550 – – –

2300 – – – 2829 – – – – 2705 –

2400 2819 2857 – – – 2685 2760 – – –

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"

A D
B C

22.5°
E
G
F

J
H K
A0020353

44 Endress+Hauser
Proline Promag L 400

DN A B C D E F G H J K 1)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 199 119 80 167 267 84 351 120 94 200

32 199 119 80 167 267 84 351 120 94 200

40 199 119 80 167 267 84 351 120 94 200

50 199 119 80 167 267 84 351 120 94 200

65 199 119 80 167 292 109 401 180 94 200

80 199 119 80 167 292 109 401 180 94 200

100 199 119 80 167 292 109 401 180 94 250

125 199 119 80 167 332 150 482 260 140 250

150 199 119 80 167 332 150 482 260 140 300

200 199 119 80 167 357 180 537 324 156 350

250 199 119 80 167 382 205 587 400 166 450

300 199 119 80 167 407 230 637 460 166 500

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

A D
B C

22.5°

E
F
H

G J

A0020393

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 199 119 80 167 431 290 550

375 199 119 80 167 457 290 600

400 199 119 80 167 457 290 600

450 199 119 80 167 485 290 600

500 199 119 80 167 510 290 600

600 199 119 80 167 551 290 600

700 199 119 80 167 616 424 700

750 199 119 80 167 653 454 750

800 199 119 80 167 672 500 800

Endress+Hauser 45
Proline Promag L 400

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

900 199 119 80 167 722 580 900

1000 199 119 80 167 772 660 1000

1050 199 119 80 167 808 755 1050

1200 199 119 80 167 886 828 1200

1350 199 119 80 167 998 1008 1350

1400 199 119 80 167 953 1008 1400

1500 199 119 80 167 1098 1147 1500

1600 199 119 80 167 1098 1147 1600

1650 199 119 80 167 1149 1284 1650

1800 199 119 80 167 1206 1379 1800

2000 199 119 80 167 1317 1569 2000

2150 199 119 80 167 1417 1711 2150

2200 199 119 80 167 1417 1711 2200

2300 199 119 80 167 1522 1859 2300

2400 199 119 80 167 1522 1859 2400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 676 683 618 698 693 490 505 520 533 525

375 – – – – 732 – – – – 550

400 727 739 672 755 747 540 565 580 597 580

450 782 792 732 802 805 595 615 640 635 640

500 832 845 795 859 862 645 670 715 699 705

600 928 941 898 957 963 755 780 840 813 825

700 1046 1063 1008 1079 1071 860 895 910 927 910

750 – – – 1145 1151 – – – 984 995

800 1160 1180 1112 1202 1202 975 1015 1025 1060 1060

900 1260 1280 1212 1306 1310 1075 1115 1125 1168 1175

1000 1360 1387 1327 1417 1400 1175 1230 1225 1289 1255

1050 – – – 1481 – – – – 1346 –

1200 1589 1614 1556 1642 1631 1405 1455 1255 1511 1490

1350 – – – 1840 – – – – 1683 –

1400 1813 1836 1768 – – 1630 1675 1685 – –

1500 – – – 2025 – – – – 1854 –

1600 2013 2056 1991 – – 1830 1915 1930 – –

1650 – – – 2165 – – – – 2032 –

1800 2228 2263 2198 2304 – 2045 2115 2130 2197 –

2000 2449 2479 2416 2498 – 2265 2325 2345 2362 –

2150 – – – 2684 – – – – 2534 –

46 Endress+Hauser
Proline Promag L 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

2200 2654 2692 – – – 2475 2550 – – –

2300 – – – 2874 – – – – 2705 –

2400 2864 2902 – – – 2685 2760 – – –

Transmitter remote version

Order code for "Housing", option N "Remote, polycarbonate" or option P "Remote, aluminum coated"

B
C
E
D

A F

G
H

A0020522

A B C D E F G H
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

167 24 187 21 232 80 50 240

Endress+Hauser 47
Proline Promag L 400

Sensor remote version

B
D
C
F
E G

A0017282

DN A B C D E F G 1)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 136 207 84 291 120 94 200

32 136 207 84 291 120 94 200

40 136 207 84 291 120 94 200

50 136 207 84 291 120 94 200

65 136 232 109 341 180 94 200

80 136 232 109 341 180 94 200

100 136 232 109 341 180 94 250

125 136 272 150 422 260 140 250

150 136 272 150 422 260 140 300

200 136 297 180 477 324 156 350

250 136 322 205 527 400 156 450

300 136 347 230 577 460 166 500

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

A
B
C

D F
A0017284

48 Endress+Hauser
Proline Promag L 400

DN A B E F

[mm] [mm] [mm] [mm] [mm]

350 136 358 290 550

375 136 384 290 600

400 136 384 290 600

450 136 412 290 600

500 136 437 290 600

600 136 478 290 600

700 136 543 424 700

750 136 579 454 750

800 136 599 500 800

900 136 649 580 900

1000 136 699 660 1000

1050 136 735 755 1050

1200 136 813 828 1200

1350 136 925 1008 1350

1400 136 925 1008 1400

1500 136 1025 1147 1500

1600 136 1025 1147 1600

1650 136 1076 1284 1650

1800 136 1133 1379 1800

2000 136 1244 1569 2000

2150 136 1344 1711 2150

2200 136 1344 1711 2200

2300 136 1449 1859 2300

2400 136 1449 1859 2400

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS


DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 603 610 616 625 620 490 505 520 533 525

375 – – – – 659 – – – – 550

400 654 666 672 682 674 540 565 580 597 580

450 709 719 729 729 732 595 615 640 635 640

500 759 772 791 786 789 645 670 715 699 705

600 855 868 903 884 890 755 780 840 813 825

700 973 990 1009 1006 998 860 895 910 927 910

750 – – – 1072 1078 – – – 984 995

800 1087 1107 1123 1129 1129 975 1015 1025 1060 1060

900 1187 1207 1223 1233 1237 1075 1115 1125 1168 1175

1000 1287 1314 1338 1344 1327 1175 1230 1225 1289 1255

1050 – – – 1408 – – – – 1346 –

Endress+Hauser 49
Proline Promag L 400

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

1200 1516 1541 1567 1569 1558 1405 1455 1255 1511 1490

1350 – – – 1767 – – – – 1683 –

1400 1740 1763 1779 – – 1630 1675 1685 – –

1500 – – – 1952 – – – – 1854 –

1600 1940 1983 2002 – – 1830 1915 1930 – –

1650 – – – 2092 – – – – 2032 –

1800 2155 2190 2209 2231 – 2045 2115 2130 2197 –

2000 2376 2406 2427 2425 – 2265 2325 2345 2362 –

2150 – – – 2611 – – – – 2534 –

2200 2581 2619 – – – 2475 2550 – – –

2300 – – – 2801 – – – – 2705 –

2400 2791 2829 – – – 2685 2760 – – –

Order code for "Sensor option", option CK "IP68, Type 6P, waterproof"

B
C

D F
A0020436

DN A B C D E F

[mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 112 364 617 520 290 550

375 112 390 – – 290 600

400 112 390 673 580 290 600

450 112 418 730 640 290 600

500 112 443 792 715 290 600

600 112 484 904 840 290 600

700 112 549 1010 910 424 700

750 112 585 – – 454 750

800 112 605 1224 1025 500 800

50 Endress+Hauser
Proline Promag L 400

DN A B C D E F

[mm] [mm] [mm] [mm] [mm] [mm] [mm]

900 112 655 1224 1125 580 900

1000 112 705 1339 1225 660 1000

1050 112 741 – – 755 1050

1200 112 819 1568 1255 828 1200

1350 112 931 – – 1008 1350

1400 112 931 1780 1685 1008 1400

1500 112 1031 – – 1147 1500

1600 112 1031 2003 1930 1147 1600

1650 112 1082 – – 1284 1650

1800 112 1139 2210 2130 1379 1800

2000 112 1250 2428 2345 1569 2000

Accessories

Ground disks for flange connections

DN ≤ 300 (12") DN 300…600 (14…24") DN ≥ 700 (28")


! 9 (0.35) ! 6.4 (0.25)
! 6.5 (0.26)

H
H
H

!B A
!B ! !D !A !D
!A !D

t = 2 (0.08) t = 2 (0.08) t = 2 (0.08)


A0015442

 29 Engineering unit mm (in)

DN Pressure rating A B D H

[mm] [mm] [mm] [mm] [mm]


1)
25 26 62 77.5 87.5
1)
32 35 80 87.5 94.5
1)
40 41 82 101 103
1)
50 52 101 115.5 108
1)
65 68 121 131.5 118
1)
80 80 131 154.5 135
1)
100 104 156 186.5 153
1)
125 130 187 206.5 160
1)
150 158 217 256 184
1)
200 206 267 288 205
1)
250 260 328 359 240
1)
300 312 375 413 273

Endress+Hauser 51
Proline Promag L 400

DN Pressure rating A B D H

[mm] [mm] [mm] [mm] [mm]

350 DIN, PN 6 343 433 479 365

350 DIN, PN 10 343 400 479 365

350 ASME, Class 343 400 479 365


150

400 DIN, PN 6 393 470 542 395

400 DIN, PN 10 393 469 542 395

400 ASME, Class 393 469 542 395


150

450 DIN, PN 6 439 525 583 417

450 DIN, PN 10 439 535 583 417

450 ASME, Class 439 535 583 417


150

500 DIN, PN 6 493 575 650 460

500 DIN, PN 10 493 588 650 460

500 ASME, Class 493 588 650 460


150

600 DIN, PN 6 593 676 766 522

600 DIN, PN 10 593 688 766 522

600 ASME, Class 593 688 766 522


150

700 DIN, PN 6 697 – 786 460

700 DIN, PN 10 693 – 813 480

700 AS, PN 16 687 – 807 490

700 AWWA, Class D 693 – 832 494

750 AWWA, Class D 743 – 833 523

800 DIN, PN 6 799 – 893 520

800 DIN, PN 10 795 – 920 540

800 AS, PN 16 789 – 914 550

800 AWWA, Class D 795 – 940 561

900 DIN, PN 6 897 – 993 570

900 DIN, PN 10 893 – 1 020 590

900 AS, PN 16 886 – 1 014 595

900 AWWA, Class D 893 – 1 048 615

1 000 DIN, PN 6 999 – 1 093 620

1 000 DIN, PN 10 995 – 1 127 650

1 000 AS, PN 16 988 – 1 131 660

1 000 AWWA, Class D 995 – 1 163 675

1 050 AWWA, Class D 1 044 – 1 220 704

1 200 DIN, PN 6 1 203 – 1 310 733

1) Ground disks can be used for all the flange standards/pressure ratings which can be supplied in the
standard version.

52 Endress+Hauser
Proline Promag L 400

Dimensions in US units Compact version

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated"

A D
B C

E
G
F
J
H K
A0020352

DN A B C D E F G H J K 1)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

1½ 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

2 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

3 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 7.87

4 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 9.84

6 7.60 4.06 3.54 6.57 11.3 5.91 17.2 10.2 5.51 11.8

8 7.60 4.06 3.54 6.57 12.3 7.09 19.4 12.8 6.14 13.8

10 7.60 4.06 3.54 6.57 13.3 8.07 21.3 15.8 6.54 17.7

12 7.60 4.06 3.54 6.57 14.3 9.06 23.3 18.1 6.54 19.7

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

A D
B C
E
F

G J

A0017153

Endress+Hauser 53
Proline Promag L 400

DN A B C D E H J

[in] [in] [in] [in] [in] [in] [in] [in]

14 7.60 4.06 3.54 6.57 15.2 11.4 21.6

15 7.60 4.06 3.54 6.57 16.2 11.4 23.6

16 7.60 4.06 3.54 6.57 16.2 11.4 23.6

18 7.60 4.06 3.54 6.57 17.3 11.4 23.6

20 7.60 4.06 3.54 6.57 18.3 11.4 23.6

24 7.60 4.06 3.54 6.57 19.9 11.4 23.6

28 7.60 4.06 3.54 6.57 22.5 16.7 27.6

30 7.60 4.06 3.54 6.57 23.9 17.9 29.5

32 7.60 4.06 3.54 6.57 24.7 19.7 31.5

36 7.60 4.06 3.54 6.57 26.6 22.8 35.4

40 7.60 4.06 3.54 6.57 28.6 26.0 39.4

42 7.60 4.06 3.54 6.57 30.0 29.7 41.3

48 7.60 4.06 3.54 6.57 33.1 32.6 47.2

54 7.60 4.06 3.54 6.57 37.5 39.7 53.1

60 7.60 4.06 3.54 6.57 41.4 45.2 59.0

66 7.60 4.06 3.54 6.57 43.4 50.6 64.9

72 7.60 4.06 3.54 6.57 45.7 54.3 70.8

78 7.60 4.06 3.54 6.57 50.1 61.8 78.7

84 7.60 4.06 3.54 6.57 54.0 67.4 84.6

90 7.60 4.06 3.54 6.57 58.1 73.2 90.5

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 24.8 25.1 27.6 25.7 25.5 19.3 19.9 20.5 21.0 20.7

15 – – – – 27 – – – – 21.7

16 26.8 27.3 30.0 27.0 27.6 21.3 22.2 22.8 23.5 22.8

18 29.0 29.4 32.4 29.8 29.9 23.4 24.2 25.2 25.0 25.2

20 31.0 31.5 36.5 32.0 32.1 25.4 26.4 28.1 27.5 27.8

24 34.7 35.3 40.4 35.9 36.1 29.7 30.7 33.1 32.0 32.5

28 39.4 40.1 45.1 40.7 40.4 33.9 35.2 35.8 36.5 35.8

30 – – – 43.3 43.5 – – – 38.7 39.2

32 43.9 44.7 48.8 45.5 45.5 38.4 40.0 40.4 41.7 41.7

36 47.8 48.6 48.8 49.6 49.8 42.3 43.9 44.3 46.0 46.3

40 51.7 52.8 53.4 54.0 53.3 46.3 48.4 48.2 50.7 49.4

42 – – – 56.5 – – – – 53.0 –

48 60.8 61.7 62.4 62.9 62.4 55.3 57.3 49.4 59.5 58.7

54 – – – 70.6 – – – – 66.3 –

60 – – – 77.9 – – – – 73.0 –

66 – – – 83.4 – – – – 80.0 –

54 Endress+Hauser
Proline Promag L 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

72 85.9 87.3 87.6 88.9 – 80.5 83.3 83.9 86.5 –

78 94.6 95.8 96.2 96.6 – 89.2 91.5 92.3 93.0 –

84 – – – 104.0 – – – – 99.8 –

90 – – – 111.0 – – – – – –

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"

A D
B C

22.5°

E
G
F
J
H K
A0020353

DN A B C D E F G H J K 1)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

1½ 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

2 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

3 7.83 4.69 3.15 6.57 11.5 4.29 15.8 7.09 3.70 7.87

4 7.83 4.69 3.15 6.57 11.5 4.29 15.8 7.09 3.70 9.84

6 7.83 4.69 3.15 6.57 13.1 5.91 19.0 10.2 5.51 11.8

8 7.83 4.69 3.15 6.57 14.1 7.09 21.1 12.8 6.14 13.8

10 7.83 4.69 3.15 6.57 15.0 8.07 23.1 15.8 6.54 17.7

12 7.83 4.69 3.15 6.57 16.0 9.06 25.1 18.1 6.54 19.7

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Endress+Hauser 55
Proline Promag L 400

A D
B C

22.5°

E
F
H

G J

A0020393

DN A B C D E H J

[in] [in] [in] [in] [in] [in] [in] [in]

14 7.83 4.69 3.15 6.57 17.0 11.4 21.6

15 7.83 4.69 3.15 6.57 18.0 11.4 23.6

16 7.83 4.69 3.15 6.57 18.0 11.4 23.6

18 7.83 4.69 3.15 6.57 19.1 11.4 23.6

20 7.83 4.69 3.15 6.57 20.1 11.4 23.6

24 7.83 4.69 3.15 6.57 21.7 11.4 23.6

28 7.83 4.69 3.15 6.57 24.3 16.7 27.6

30 7.83 4.69 3.15 6.57 25.7 17.9 29.5

32 7.83 4.69 3.15 6.57 26.5 19.7 31.5

36 7.83 4.69 3.15 6.57 28.4 22.8 35.4

40 7.83 4.69 3.15 6.57 30.4 26.0 39.4

42 7.83 4.69 3.15 6.57 31.8 29.7 41.3

48 7.83 4.69 3.15 6.57 34.9 32.6 47.2

54 7.83 4.69 3.15 6.57 39.3 39.7 53.1

60 7.83 4.69 3.15 6.57 43.2 45.2 59.0

66 7.83 4.69 3.15 6.57 45.2 50.6 64.9

72 7.83 4.69 3.15 6.57 47.5 54.3 70.8

78 7.83 4.69 3.15 6.57 51.9 61.8 78.7

84 7.83 4.69 3.15 6.57 55.8 67.4 84.6

90 7.83 4.69 3.15 6.57 59.9 73.2 90.5

56 Endress+Hauser
Proline Promag L 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 26.6 26.9 24.3 27.5 27.3 19.3 19.9 20.5 21.0 20.7

15 – – – – 28.8 – – – – 21.7

16 28.6 29.1 26.5 28.8 29.4 21.3 22.2 22.8 23.5 22.8

18 30.8 31.2 28.8 31.6 31.7 23.4 24.2 25.2 25.0 25.2

20 32.8 33.3 31.3 33.8 33.9 25.4 26.4 28.1 27.5 27.8

24 36.5 37.1 35.4 37.7 37.9 29.7 30.7 33.1 32.0 32.5

28 41.2 41.9 39.7 42.5 42.2 33.9 35.2 35.8 36.5 35.8

30 – – – 45.1 45.3 – – – 38.7 39.2

32 45.7 46.5 43.8 47.3 47.3 38.4 40.0 40.4 41.7 41.7

36 49.6 50.4 47.7 51.4 49.8 42.3 43.9 44.3 46.0 46.3

40 53.5 54.6 52.2 55.8 55.1 46.3 48.4 48.2 50.7 49.4

42 – – – 58.3 – – – – 53.0 –

48 62.6 63.5 61.3 64.7 64.2 55.3 57.3 49.4 59.5 58.7

54 – – – 72.4 – – – – 66.3 –

60 – – – 79.7 – – – – 73.0 –

66 – – – 85.2 – – – – 80.0 –

72 87.7 89.1 86.5 90.7 – 80.5 83.3 83.9 86.5 –

78 96.4 97.6 95.1 98.4 – 89.2 91.5 92.3 93.0 –

84 – – – 105.8 – – – – 99.8 –

90 – – – 112.8 – – – – – –

Endress+Hauser 57
Proline Promag L 400

Transmitter remote version

Order code for "Housing", option N "Remote, polycarbonate" or option P "Remote, aluminum coated"

B
C
E
D
A F

A0020522

A B C D E F G H
[in] [in] [in] [in] [in] [in] [in] [in]

6.57 0.94 7.36 0.83 9.13 3.15 1.97 9.5

Sensor remote version

A
B
D
C

F
E G

A0017282

58 Endress+Hauser
Proline Promag L 400

DN A B C D E F G 1)

[in] [in] [in] [in] [in] [in] [in] [in]

1 5.35 8.15 3.31 11.5 4.72 3.70 7.87

1½ 5.35 8.15 3.31 11.5 4.72 3.70 7.87

2 5.35 8.15 3.31 11.5 4.72 3.70 7.87

3 5.35 9.13 4.29 13.4 7.09 3.70 7.87

4 5.35 9.13 4.29 13.4 7.09 3.70 9.84

6 5.35 10.7 5.91 16.6 10.2 5.51 11.8

8 5.35 11.7 7.09 18.8 12.8 6.14 13.8

10 5.35 12.7 8.07 20.8 15.8 6.14 17.7

12 5.35 13.7 9.06 22.8 18.1 6.54 19.7

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

B
C
E

D F
A0017284

DN A B E F

[in] [in] [in] [in] [in]

14 5.35 14.1 11.4 21.6

15 5.35 15.1 11.4 23.6

16 5.35 15.1 11.4 23.6

18 5.35 16.2 11.4 23.6

20 5.35 17.2 11.4 23.6

24 5.35 18.8 11.4 23.6

28 5.35 21.6 16.7 27.6

30 5.35 23.0 17.9 29.5

32 5.35 23.6 19.7 31.5

36 5.35 25.6 22.8 35.4

40 5.35 27.5 26.0 39.4

42 5.35 28.9 29.7 41.3

48 5.35 32.0 32.6 47.2

54 5.35 36.4 39.6 53.1

Endress+Hauser 59
Proline Promag L 400

DN A B E F

[in] [in] [in] [in] [in]

60 5.35 40.4 45.2 59.0

66 5.35 42.4 50.6 64.9

72 5.35 44.6 54.2 70.8

78 5.35 49.0 61.8 78.7

84 5.35 52.9 67.4 84.6

90 5.35 57.1 73.2 90.5

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 23.7 24.0 24.3 24.6 24.4 19.3 19.9 20.5 21.0 20.7

15 – – – – 25.9 – – – – 21.7

16 25.8 26.2 26.5 26.9 26.5 21.3 22.2 22.8 23.5 22.8

18 27.9 28.3 28.7 28.7 28.8 23.4 24.2 25.2 25.0 25.2

20 29.9 30.4 31.1 30.9 31.1 25.4 26.4 28.1 27.5 27.8

24 33.7 34.2 35.6 34.8 35.0 29.7 30.7 33.1 32.0 32.5

28 38.5 39.2 39.7 39.8 39.5 33.9 35.2 35.8 36.5 35.8

30 – – – 42.4 42.4 – – – 38.7 39.2

32 43.0 43.8 44.2 44.6 44.6 38.4 40.0 40.4 41.7 41.7

36 46.9 47.7 48.2 48.7 48.9 42.3 43.9 44.3 46.0 46.3

40 50.8 51.9 52.7 53.1 52.4 46.3 48.4 48.2 50.7 49.4

42 – – – 55.6 – – – – 53.0 –

48 59.9 60.8 61.7 62.0 61.5 55.3 57.3 49.4 59.5 58.7

54 – – – 69.6 – – – – 66.3 –

60 – – – 76.9 – – – – 73.0 –

66 – – – 82.4 – – – – 80.0 –

72 84.9 86.3 87.0 87.9 – 80.5 83.3 83.9 86.5 –

78 93.6 94.7 95.6 95.5 – 89.2 91.5 92.3 93.0 –

84 – – – 102.8 – – – – 99.8 –

90 – – – 110.3 – – – – 106.5 –

60 Endress+Hauser
Proline Promag L 400

Order code for "Sensor option", option CK "IP68, Type 6P, waterproof"

B
C
E

D F
A0020436

DN A B C D E F

[in] [in] [in] [in] [in] [in] [in]

14 4.41 14.3 24.3 20.5 11.4 21.6

15 4.41 15.4 – – 11.4 23.6

16 4.41 15.4 26.5 22.8 11.4 23.6

18 4.41 16.5 28.7 25.2 11.4 23.6

20 4.41 17.4 31.2 28.1 11.4 23.6

24 4.41 19.1 35.6 33.1 11.4 23.6

28 4.41 21.6 39.8 35.8 16.7 27.6

30 4.41 23.0 – – 17.9 29.5

32 4.41 23.8 44.2 40.4 19.7 31.5

36 4.41 25.8 48.2 44.3 22.8 35.4

40 4.41 27.8 52.7 48.2 26.0 39.4

42 4.41 29.2 – – 29.7 41.3

48 4.41 32.2 61.7 49.4 32.6 47.2

54 4.41 36.7 – – 39.6 53.1

60 4.41 40.6 – – 45.2 59.0

66 4.41 42.6 – – 50.6 64.9

72 4.41 44.8 87.0 83.9 54.2 70.8

78 4.41 49.2 95.6 92.3 61.8 78.7

Endress+Hauser 61
Proline Promag L 400

Accessories

Ground disks for flange connections

DN ≤ 300 (12") DN 300…600 (14…24") DN ≥ 700 (28")


! 9 (0.35) ! 6.4 (0.25)
! 6.5 (0.26)

H
H
H

!B A
!B ! !D !A !D
!A !D

t = 2 (0.08) t = 2 (0.08) t = 2 (0.08)


A0015442

 30 Engineering unit mm (in)

DN Pressure rating A B D H

[in] [in] [in] [in] [in]


1)
1 1.02 2.44 3.05 3.44
1)
1¼ 1.38 3.15 3.44 3.72
1)
1½ 1.61 3.23 3.98 4.06
1)
2 2.05 3.98 4.55 4.25
1)
2½ 2.68 4.76 5.18 4.65
1)
3 3.15 5.16 6.08 5.31
1)
4 4.09 6.14 7.34 6.02
1)
5 5.12 7.36 8.13 6.30
1)
6 6.22 8.54 10.1 7.24
1)
8 8.11 10.5 11.3 8.07
1)
10 10.2 12.9 14.1 9.45
1)
12 12.3 14.8 16.3 10.8

14 DIN, PN 6 13.5 16.5 18.9 14.4

14 DIN, PN 10 13.5 15.8 18.9 14.4

14 ASME, Class 13.5 15.8 18.9 14.4


150

16 DIN, PN 6 15.5 18.5 21.3 15.6

16 DIN, PN 10 15.5 18.5 21.3 15.6

16 ASME, Class 15.5 18.5 21.3 15.6


150

18 DIN, PN 6 17.3 20.7 23.0 16.4

18 DIN, PN 10 17.3 21.1 23.0 16.4

18 ASME, Class 17.3 21.1 23.0 16.4


150

20 DIN, PN 6 19.4 23.3 25.6 18.1

20 DIN, PN 10 19.4 23.2 25.6 18.1

20 ASME, Class 19.4 23.2 25.6 18.1


150

62 Endress+Hauser
Proline Promag L 400

DN Pressure rating A B D H

[in] [in] [in] [in] [in]

24 DIN, PN 6 23.4 27.3 30.2 20.6

24 DIN, PN 10 23.4 27.1 30.2 20.6

24 ASME, Class 23.4 27.1 30.2 20.6


150

28 DIN, PN 6 27.4 – 30.9 18.1

28 DIN, PN 10 27.3 – 32.0 18.9

28 AS, PN 16 27.1 – 31.8 19.3

28 AWWA, Class D 27.3 – 32.8 19.5

30 AWWA, Class D 29.3 – 32.8 20.6

32 DIN, PN 6 31.5 – 35.2 20.5

32 DIN, PN 10 31.3 – 36.2 21.3

32 AS, PN 16 31.1 – 36.0 21.7

32 AWWA, Class D 31.3 – 37.0 22.1

36 DIN, PN 6 35.3 – 39.1 22.4

36 DIN, PN 10 35.2 – 40.2 23.2

36 AS, PN 16 34.9 – 39.9 23.4

36 AWWA, Class D 35.2 – 41.3 24.2

40 DIN, PN 6 39.3 – 43.0 24.4

40 DIN, PN 10 39.2 – 44.4 25.6

40 AS, PN 16 38.9 – 44.5 26.0

40 AWWA, Class D 39.2 – 45.8 26.6

42 AWWA, Class D 41.1 – 48.0 27.7

48 DIN, PN 6 47.4 – 51.6 28.9

1) Ground disks can be used for all the flange standards/pressure ratings which can be supplied in the
standard version.

Weight Compact version


Weight data:
• Including the transmitter
– Order code for "Housing", option M, Q: 1.3 kg (2.9 lb)
– Order code for "Housing", option A, R: 2.0 kg (4.4 lb)
• Excluding packaging material

Weight in SI units

Lap joint flange; fixed flange DN ≥ 350

EN 1092-1 (DIN 2501)

DN Order code for "Housing", option M, Q


[mm] Polycarbonate plastic 1)

Weight [kg]

PN 6 PN 10 PN 16

25 – – 6.8

32 – – 7.5

40 – – 8.5

50 – – 9

Endress+Hauser 63
Proline Promag L 400

EN 1092-1 (DIN 2501)

DN Order code for "Housing", option M, Q


[mm] Polycarbonate plastic 1)

Weight [kg]

PN 6 PN 10 PN 16

65 – – 10

80 – – 12

100 – – 14

125 – – 20

150 – – 24

200 – 43 44.4

250 – 63 70.2

300 – 68 85.3

350 77 88 103

400 89 104 121

450 99 112 138

500 114 132 178

600 155 162 223

700 190 240 287

800 240 315 349

900 308 393 440

1 000 359 468 562

1 200 529 717 839

1 400 784 1 114 1 200

1 600 1 058 1 624 1 840

1 800 1 484 2 107 2 353

2 000 1 877 2 630 2 925

2 200 2 512 3 422 –

2 400 2 996 4 094 –

1) Values for aluminum transmitter, AlSi10Mg, coated: + 0.7 kg

AS 2129, Table E

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

350 99 99.7

400 120 120.7

450 143 143.7

500 182 182.7

600 260 260.7

700 346 346.7

750 433 433.7

800 493 493.7

900 690 690.7

64 Endress+Hauser
Proline Promag L 400

AS 2129, Table E

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

1 000 761 761.7

1 200 1 237 1 237.7

AS 4087, PN 16

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

350 99 99.7

375 105 105.7

400 120 120.7

450 133 133.7

500 182 182.7

600 260 260.7

700 367 367.7

750 445 445.7

800 503 503.7

900 702 702.7

1 000 759 759.7

1 200 1 219 1 219.7

Lap joint flange, stamped plate

EN 1092-1 (DIN 2501), PN 10

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

25 5.3 6.0

32 5.1 5.8

40 5.8 6.5

50 5 5.7

65 6 6.7

80 7 7.7

100 9 9.7

125 13 13.7

150 17 17.7

200 35 35.7

250 54 54.7

300 55 55.7

Endress+Hauser 65
Proline Promag L 400

Weight in US units

Lap joint flange; fixed flange DN ≥ 14"

ASME B16.5, Class 150

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

1 11.6 13.2

1½ 12.8 14.3

2 20 21.5

3 26 27.5

4 31 32.5

6 53 54.5

8 95 96.5

10 139 140.5

12 150 151.5

14 302 303.5

16 370 371.5

18 421 422.5

20 503 504.5

24 666 667.5

AWWA C207, Class D

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

28 586 587.5

30 701 702.5

32 844 845.5

36 1 036 1 037.5

40 1 294 1 295.5

42 1 477 1 478.5

48 1 987 1 988.5

54 2 807 2 808.5

60 3 515 3 516.5

66 4 699 4 700.5

72 5 662 5 663.5

78 6 864 6 865.5

84 8 280 8 281.5

90 10 577 10 578.5

66 Endress+Hauser
Proline Promag L 400

Transmitter remote version

Wall-mount housing
Depends on the material of the wall-mount housing:
• Polycarbonate plastic: 1.3 kg (2.9 lb)
• Aluminum, AlSi10Mg, coated: 2.0 kg (4.4 lb)

Sensor remote version


Weight data:
• Including sensor connection housing
• Excluding the connecting cable
• Excluding packaging material

Weight in SI units

Lap joint flange; fixed flange DN ≥ 350

EN 1092-1 (DIN 2501)

DN Weight [kg]
[mm]
PN 6 PN 10 PN 16

25 – – 6.8

32 – – 7.5

40 – – 8.5

50 – – 6

65 – – 7

80 – – 9

100 – – 11

125 – – 16

150 – – 20

200 – 40 44.4

250 – 60 70.2

300 – 65 85.3

350 73 84 101

400 85 100 119

450 95 108 136

500 110 128 176

600 158 158 221

700 187 237 285

800 237 312 347

900 305 390 438

1 000 356 465 560

1 200 526 714 837

1 400 781 1 111 1 197

1 600 1 055 1 621 1 838

1 800 1 415 2 104 2 350

2 000 1 874 2 627 2 922

2 200 2 509 3 419 –

2 400 2 993 4 091 –

Endress+Hauser 67
Proline Promag L 400

AS 2129, Table E

DN Weight
[mm] [kg]

350 95

400 116

450 139

500 178

600 256

700 343

750 430

800 490

900 687

1 000 758

1 200 1 234

AS 4087, PN 16

DN Weight
[mm] [kg]

350 95

375 101

400 116

450 129

500 178

600 256

700 364

750 442

800 500

900 699

1 000 756

1 200 1 216

Lap joint flange, stamped plate

EN 1092-1 (DIN 2501), PN 10

DN [kg]
[mm]

25 6.0

32 5.8

40 6.5

50 3

65 4

80 5

100 7

125 11

150 15

68 Endress+Hauser
Proline Promag L 400

EN 1092-1 (DIN 2501), PN 10

DN [kg]
[mm]

200 33

250 52

300 53

Weight in US units

Lap joint flange; fixed flange DN ≥ 14"

ASME B16.5, Class 150

DN Weight
[in] [lbs]

1 13.2

1½ 14.3

2 13

3 20

4 24

6 44

8 88

10 132

12 143

14 293

15 –

16 361

18 412

20 494

24 657

AWWA C207, Class D

DN Weight
[in] [lbs]

28 580

30 695

32 838

36 1 030

40 1 288

42 1 471

48 1 980

54 2 800

60 3 508

66 4 692

72 5 656

78 6 858

Endress+Hauser 69
Proline Promag L 400

AWWA C207, Class D

DN Weight
[in] [lbs]

84 8 273

90 10 571

Measuring tube specification Nominal diameter Pressure rating Measuring tube internal diameter

EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE

AWWA AS 4087

[mm] [in] [mm] [in] [mm] [in] [mm] [in]

25 1 PN 10/16 Class 150 – – – 23.7 0.9 25.3 1.0

32 1¼ PN 10/16 Class 150 – – – 32.4 1.3 34.0 1.3

40 1½ PN 10/16 Class 150 – – – 38.3 1.5 39.9 1.6

50 2 PN 10/16 Class 150 – – – 50.3 2.0 51.7 2.0


1)
65 2½ PN 10/16 Class 150 – – – 66.1 2.6 67.7 2.7

80 3 PN 10/16 Class 150 – – – 78.9 3.1 79.9 3.1

100 4 PN 10/16 Class 150 – – – 104.3 4.1 103.8 4.1

125 5 PN 10/16 Class 150 – – – 129.7 5.1 129.1 5.1

150 6 PN 10/16 Class 150 – – – 158.3 6.2 156.3 6.2

200 8 PN 10/16 Class 150 – – – 206.7 8.1 202.1 8.0

250 10 PN 10/16 Class 150 – – – 260.6 10.3 256.2 10.1

300 12 PN 10/16 – – – – 311.5 12.3 305.5 12.0

300 12 – Class 150 – – – 309.9 12.2 303.9 12.0

350 14 PN 6 – – 341 13.4 344 13.5 – –

350 14 PN 10 – – 341 13.4 344 13.5 – –

350 14 – – Table E, PN 16 339 13.3 342 13.4 – –

350 14 – Class 150 – 339 13.3 342 13.4 – –

375 15 PN 10 – – 391 15.4 – – – –

375 15 – – PN 16 389 15.3 392 15.4 – –

400 16 PN 6 – – 391 15.4 394 13.5 – –

400 16 PN 10 – – 442 17.4 394 13.5 – –

400 16 – – Table E, PN 16 389 15.3 392 13.4 – –

400 16 – Class 150 – 389 15.3 392 13.4 – –

450 18 PN 6 – – 442 17.4 445 17.5 – –

450 18 PN 10 – – 493 19.4 445 17.5 – –

450 18 – – Table E, PN 16 440 17.3 443 17.4 – –

450 18 – Class 150 – 438 17.2 441 17.3 – –

500 20 PN 6 – – 493 19.4 496 19.5 – –

500 20 PN 10 – – 595 23.4 496 19.5 – –

500 20 – – Table E, PN 16 489 19.2 492 19.3 – –

500 20 – Class 150 – 489 19.2 492 19.3 – –

600 24 PN 6 – – 595 23.4 598 23.5 – –

600 24 PN 10 – – 590 23.2 598 23.5 – –

600 24 – – Table E, PN 16 591 23.2 594 23.4 – –

70 Endress+Hauser
Proline Promag L 400

Nominal diameter Pressure rating Measuring tube internal diameter

EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE

AWWA AS 4087

[mm] [in] [mm] [in] [mm] [in] [mm] [in]

600 24 – Class 150 – 589 23.1 592 23.3 – –

700 28 PN 6 – – 696 27.4 699 27.5 – –

700 28 PN 10 – – 694 27.3 697 27.4 – –

700 28 – – Table E, PN 16 690 27.2 693 27.3 – –

700 28 – Class D – 694 27.3 697 27.4 – –

750 30 PN 6 – – – – 699 27.5 – –

750 30 PN 10 – – – – 697 27.4 – –

750 30 – – Table E, PN 16 741 29.2 744 29.3 – –

750 30 – Class D – 743 29.3 746 29.4 – –

800 32 PN 6 – – 798 31.4 801 31.5 – –

800 32 PN 10 – – 796 31.3 799 31.5 – –

800 32 – – Table E, PN 16 792 31.2 795 31.3 – –

800 32 – Class D – 794 31.3 797 31.4 – –

900 36 PN 6 – – 897 35.3 900 35.4 – –

900 36 PN 10 – – 895 35.2 898 35.4 – –

900 36 – – Table E, PN 16 889 35.0 892 35.1 – –

900 36 – Class D – 895 35.2 898 35.4 – –

1 000 40 PN 6 – – 999 39.3 1 002 39.4 – –

1 000 40 PN 10 – – 997 39.3 1 000 39.4 – –

1 000 40 – – Table E, PN 16 991 39.0 994 39.1 – –

1 000 40 – Class D – 995 39.1 998 39.3 – –

1 050 42 PN 6 – – – – – – – –

1 050 42 PN 10 – – – – – – – –

1 050 42 – – Table E, PN 16 – – – – – –

1 050 42 – Class D – 1 046 41.2 1 049 41.3 – –

1 200 48 PN 6 – – 1 203 47.4 1 206 47.5 – –

1 200 48 PN 10 – – 1 199 47.2 1 202 47.3 – –

1 200 48 – – Table E, PN 16 1 191 46.9 1 194 47.0 – –

1 200 48 – Class D – 1 195 47.0 1 198 47.2 – –

– 54 – Class D – 1 345 53.8 – – – –

1 400 – PN 6 – – 1 402 56.1 – – – –

1 400 – PN 10 – – 1 394 5 578 – – – –

– 60 – Class D – 1 498 59.9 – – – –

1 600 – PN 6 – – 1 600 64.0 – – – –

1 600 – PN 10 – – 1 590 63.6 – – – –

– 66 – Class D – 1 646 65.8 1 198 47.2 – –

1 800 72 PN 6 – – 1 800 72.0 1 206 47.5 – –

1 800 72 PN 10 – – 1 790 71.6 1 202 47.3 – –

1 800 72 – Class D – 1 790 71.6 1 198 47.2 – –

2 000 78 PN 6 – – 1 998 79.9 – – – –

Endress+Hauser 71
Proline Promag L 400

Nominal diameter Pressure rating Measuring tube internal diameter

EN (DIN) ASME AS 2129 Hard rubber Polyurethane PTFE

AWWA AS 4087

[mm] [in] [mm] [in] [mm] [in] [mm] [in]

2 000 78 PN 10 – – 1 990 79.6 – – – –

2 000 78 – Class D – 1 986 79.4 – – – –

– 84 – Class D – 2 099 84.0 – – – –

2 200 – PN 6 – – 2 194 87.8 – – – –

2 200 – PN 10 – – 2 186 87.4 – – – –

– 90 – Class D – 2 246 89.8 – – – –

2 400 – PN 6 – – 2 394 95.8 – – – –

2 400 – PN 10 – – 2 386 95.4 – – – –

1) Designed acc. to EN 1092-1 (not to DIN 2501)

Materials Transmitter housing

Compact version, standard


• Order code for "Housing", option A "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option M: polycarbonate plastic
• Window material:
– For order code for "Housing", option A: glass
– For order code for "Housing", option M: plastic

Compact version, inclined


• Order code for "Housing", option R "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option Q: polycarbonate plastic
• Window material:
– For order code for "Housing", option R: glass
– For order code for "Housing", option Q: plastic

Remote version (wall-mount housing)


• Order code for "Housing", option P "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option N: polycarbonate plastic
• Window material:
– For order code for "Housing", option P: glass
– For order code for "Housing", option N: plastic

72 Endress+Hauser
Proline Promag L 400

Cable entries/cable glands

3
A0020640

 31 Possible cable entries/cable glands


1 Cable entry in transmitter housing, wall-mount housing or connection housing with internal thread M20 x
1.5
2 Cable gland M20 x 1.5
3 Adapter for cable entry with internal thread G ½" or NPT ½"

Compact and remote versions and sensor connection housing

Cable entry/cable gland Material

Cable gland M20 × 1.5 Plastic

Remote version: cable gland M20 × 1.5 • Sensor connection housing:


Nickel-plated brass
• Option CK "IP68, Type 6P, waterproof"
• Transmitter wall-mount housing:
• Option of reinforced connecting cable
Plastic

Adapter for cable entry with internal thread G ½" or Nickel-plated brass
NPT ½"

Device plug

Electrical connection Material

Plug M12x1 • Socket: Stainless steel, 1.4404 (316L)


• Contact housing: Polyamide
• Contacts: Gold-plated brass

Connecting cable for remote version


Electrode and coil current cable
• Standard cable: PVC cable with copper shield
• Reinforced cable: PVC cable with copper shield and additional steel wire braided jacket

Sensor housing
• DN 25 to 300 (1 to 12"): aluminum, AlSi10Mg, coated
• DN 350 to 2400 (14 to 90"): carbon steel with protective varnish

Sensor connection housing


Aluminum, AlSi10Mg, coated

Measuring tubes
• DN 25 to 300 (1 to 12"): stainless steel, 1.4301/1.4306/304L
• DN 350 to 1200 (14 to 48"): stainless steel, 1.4301/1.4307/202/304
• DN 1350 to 2400 (54 to 90"): stainless steel, 1.4301/1.4307

Endress+Hauser 73
Proline Promag L 400

Liner
• DN 25 to 300 (1 to 12"): PTFE
• DN 25 to 1200 (1 to 48"): polyurethane
• DN 350 to 2400 (14 to 90"): hard rubber

Electrodes
• Stainless steel, 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)

Process connections

EN 1092-1 (DIN 2501)


DN 25 to 300:
• Fixed flange
– Stainless steel, 1.4306/1.4404/1.4571/F316L
– Carbon steel, A105/FE410WB/S235JRG2
• Lap joint flange, stamped plate
– Stainless steel, 1.4301 similar to 304
– Carbon steel, S235JRG2 similar to 1.0038 (S235JR+AR)
• DN 350 to 600:
Carbon steel, A105/FE410WB/P250GH/S235JRG2/S235JR+N
• DN 700 to 1200:
Carbon steel, A105/P250GH/S235JRG2/S235JR+N
• DN 1350 to 2400:
Carbon steel, P250GH/S235JRG2/S235JR+N

ASME B16.5
DN 25 to 300 (1 to 12"):
Fixed flange
– Stainless steel, F316L similar to 1.4404
– Carbon steel, A105 similar to 1.0432
DN 350 to 600 (14 to 24"):
Carbon steel, A105/A515 Grade 70

AWWA C207
• DN 48":
Carbon steel, A105/A181/FE410WB/P265GH/S275JR
• DN 54 to 90":
Carbon steel, A105/A181/P265GH/S275JR

AS 2129
Carbon steel, A105/FE410WB/P235GH/P265GH/S235JRG2

AS 4087
Carbon steel, A105/P265GH/S275JRG2

Seals
In accordance with DIN EN 1514-1

Accessories

Display protection
Stainless steel, 1.4301 (304L)

Ground disks
• Stainless steel, 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)

74 Endress+Hauser
Proline Promag L 400

Fitted electrodes Measurement, reference and empty pipe detection electrodes available as standard with:
• 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)

Process connections • EN 1092-1 (DIN 2501)


– DN ≤ 300: lap joint flange (PN 10/16), lap joint flange, stamped plate (PN 10) = form A
– DN ≥ 350: fixed flange (PN 6/10) = flat face
• ASME B16.5
– DN ≤ 300 (12"): lap joint flange (Class 150)
– DN ≥ 350 (14"): fixed flange (Class 150)
• AWWA C207
DN 48 to 90": fixed flange (Class D)
• AS 2129
DN 350 to 1200: fixed flange (Table E)
• AS 4087
DN 350 to 1200: fixed flange (PN 16)
For information on the materials of the process connections →  74

Surface roughness Electrodes with 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022):
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)

Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Quick and safe commissioning
• Guided menus ("Make-it-run" wizards) for applications
• Menu guidance with brief explanations of the individual parameter functions
Reliable operation
• Operation in the following languages:
– Via local display:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
– Via "FieldCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
– Via integrated Web browser (only available for device versions with HART, PROFIBUS DP and
EtherNet/IP):
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
• Uniform operating philosophy applied to device, operating tools and Web browser
• If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
Efficient diagnostics increase measurement availability
• Troubleshooting measures can be called up via the device, operating tools and Web browser
• Diverse simulation options, logbook for events that occur and optional line recorder functions

Endress+Hauser 75
Proline Promag L 400

Local operation Via display module

A0020538

Display elements
• 4-line display
• White background lighting; switches to red in event of device errors
• Format for displaying measured variables and status variables can be individually configured
• Permitted ambient temperature for the display: –20 to +50 °C (–4 to +122 °F)
The readability of the display may be impaired at temperatures outside the temperature range.
Operating elements
External operation via touch control; 3 optical keys: , , E

Additional functionality
• Data backup function
The device configuration can be saved in the display module.
• Data comparison function
The device configuration saved in the display module can be compared to the current device
configuration.
• Data transfer function
The transmitter configuration can be transmitted to another device using the display module.

Remote operation Via HART protocol


This communication interface is available in device versions with a HART output.

4 6 7

1 2 3 5
A0017124

 32 Options for remote operation via HART protocol


1 Control system (e.g. PLC)
2 Field Communicator 475
3 Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM)
4 Commubox FXA195 (USB)
5 Field Xpert SFX350 or SFX370
6 VIATOR Bluetooth modem with connecting cable
7 Transmitter

76 Endress+Hauser
Proline Promag L 400

Via PROFIBUS DP network


This communication interface is available in device versions with PROFIBUS DP.

1 2

4 4 4
A0020903

 33 Options for remote operation via PROFIBUS DP network


1 Automation system
2 Computer with PROFIBUS network card
3 PROFIBUS DP network
4 Measuring device

Via Ethernet-based fieldbus


This communication interface is available in device versions with EtherNet/IP.

1 2 3

5 5 5
A0016961

 34 Options for remote operation via Ethernet-based fieldbus


1 Control system, e.g. "RSLogix" (Rockwell Automation)
2 Workstation for measuring device operation: with Add-on Profile Level 3 for "RSLogix 5000" (Rockwell
Automation) or with Electronic Data Sheet (EDS)
3 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
4 Ethernet switch
5 Measuring device

Endress+Hauser 77
Proline Promag L 400

Service interface Via service interface (CDI-RJ45)


This communication interface is present in the following device version:
• Order code for "Output", option H: 4-20/0-20 mA HART, pulse/frequency/switch output
• Order code for "Output", option I: 4-20/0-20 mA HART, pulse/frequency/switch output, status
input
• Order code for "Output", option L: PROFIBUS DP
• Order code for "Output", option N: EtherNet/IP
• Order code for "Output", option M: Modbus RS485

HART

1 2 3

A0020481

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

PROFIBUS DP

1 2 3

A0023114

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

78 Endress+Hauser
Proline Promag L 400

EtherNet/IP

1 2 3

A0023113

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

Modbus RS485

1 2 3

A0023114

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

Certificates and approvals


CE mark The measuring system is in conformity with the statutory requirements of the applicable EC
Directives. These are listed in the corresponding EC Declaration of Conformity along with the
standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.

C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".

Ex approval The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.

Endress+Hauser 79
Proline Promag L 400

ATEX, IECEx
Currently, the following versions for use in hazardous areas are available:

Drinking water approval • ACS


• KTW/W270
• NSF 61
• WRAS BS 6920

Certification PROFIBUS PROFIBUS interface


The measuring device is certified and registered by the PROFIBUS User Organization (PNO). The
measuring system meets all the requirements of the following specifications:
• Certified in accordance with PROFIBUS PA Profile 3.02
• The device can also be operated with certified devices of other manufacturers (interoperability)

Modbus RS485 certification The measuring device meets all the requirements of the MODBUS/TCP conformity test and has the
"MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
all the test procedures carried out and is certified by the “MODBUS/TCP Conformance Test
Laboratory” of the University of Michigan.

EtherNet/IP certification The measuring device is certified and registered by the ODVA (Open Device Vendor Association).
The measuring system meets all the requirements of the following specifications:
• Certified in accordance with the ODVA Conformance Test
• EtherNet/IP Performance Test
• EtherNet/IP PlugFest compliance
• The device can also be operated with certified devices of other manufacturers (interoperability)

Other standards and • EN 60529


guidelines Degrees of protection provided by enclosures (IP code)
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use
• IEC/EN 61326
Emission in accordance with Class A requirements. Electromagnetic compatibility (EMC
requirements).
• ANSI/ISA-61010-1 (82.02.01): 2004
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part
1 General Requirements
• CAN/CSA-C22.2 No. 61010-1-04
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part
1 General Requirements
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment
• NAMUR NE 32
Data retention in the event of a power failure in field and control instruments with
microprocessors
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 105
Specifications for integrating fieldbus devices in engineering tools for field devices
• NAMUR NE 107
Self-monitoring and diagnosis of field devices
• NAMUR NE 131
Requirements for field devices for standard applications

80 Endress+Hauser
Proline Promag L 400

Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser web site: www.endress.com → Choose your
country → Products → Select measuring technology, software or components → Select product
(picklists: measurement method, product family etc.) → Device support (right-hand column):
Configure the selected product → The Product Configurator for the selected product is opened.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop

Product generation index Release date Product root Modification

01.06.2012 8S1B Original

01.01.2015 8S1C DN 08 to 50 measuring tube material 1.4435/316L


DN 40 to 50 reduction in length
DN 40 to 50 reduction in weight

Additional information is available from your sales center or at:


www.service.endress.com → Downloads

Application packages
Many different application packages are available to enhance the functionality of the device. Such
packages might be needed to address safety aspects or specific application requirements.
The application packages can be ordered with the device or subsequently from Endress+Hauser.
Detailed information on the order code in question is available from your local Endress+Hauser sales
center or on the product page of the Endress+Hauser website: www.endress.com.

Cleaning Package Description

Electrode cleaning circuit The electrode cleaning circuit (ECC) function has been developed to have a solution
(ECC) for applications where magnetite (Fe3O4) deposits frequently occur (e.g. hot
water). Since magnetite is highly conductive this build up leads to measuring errors
and ultimately to the loss of signal. The application package is designed to AVOID
build up of highly conductive matter and thin layers (typical of magnetite).

Diagnostics functions Package Description

HistoROM extended Comprises extended functions concerning the event log and the activation of the
function measured value memory.
Event log:
Memory volume is extended from 20 message entries (basic version) to up to 100
entries.
Data logging (line recorder):
• Memory capacity for up to 1000 measured values is activated.
• 250 measured values can be output via each of the 4 memory channels. The
recording interval can be defined and configured by the user.
• Data logging is visualized via the local display or FieldCare.

Endress+Hauser 81
Proline Promag L 400

Heartbeat Technology Package Description

Heartbeat Verification Heartbeat Monitoring:


+Monitoring Continuously supplies monitoring data, which are characteristic of the measuring
principle, for an external condition monitoring system. This makes it possible to:
• Draw conclusions - using these data and other information - about the impact
the measuring application has on the measuring performance over time.
• Schedule servicing in time.
• Monitor the product quality, e.g. gas pockets.
Heartbeat Verification:
Makes it possible to check the device functionality on demand when the device is
installed, without having to interrupt the process.
• Access via onsite operation or other operating interfaces, such as FieldCare for
instance.
• End-to-end, traceable documentation of the verification results, including report.
• Makes it possible to extend calibration intervals in accordance with operator's
risk assessment.

Accessories
Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are
available for the device. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.

Device-specific accessories For the transmitter

Accessories Description

Display protection Is used to protect the display against impact or scoring from sand in desert areas.

 For details, see Special Documentation SD00333F


Connecting cable for Coil current and electrode cables, various lengths, reinforced cables available on
remote version request.

Ground cable Set, consisting of two ground cables for potential equalization.

Post mounting kit Post mounting kit for transmitter.

Compact → remote For converting a compact device version to a remote device version.
conversion kit

Promag 50/53 → Promag For converting a Promag with transmitter 50/53 to a Promag 400.
400 conversion kit

For the sensor

Accessories Description

Ground disks Are used to ground the fluid in lined measuring tubes to ensure proper
measurement.

 For details, see Installation Instructions EA00070D


Communication-specific Accessories Description
accessories
Commubox FXA195 For intrinsically safe HART communication with FieldCare via the USB interface.
HART
 For details, see "Technical Information" TI00404F
HART Loop Converter Is used to evaluate and convert dynamic HART process variables to analog current
HMX50 signals or limit values.

 BA00371F
For details, see "Technical Information" TI00429F and Operating Instructions

82 Endress+Hauser
Proline Promag L 400

Wireless HART adapter Is used for the wireless connection of field devices.
SWA70 The WirelessHART adapter can be easily integrated into field devices and existing
infrastructures, offers data protection and transmission safety and can be operated
in parallel with other wireless networks with minimum cabling complexity.

 For details, see Operating Instructions BA00061S


Fieldgate FXA320 Gateway for the remote monitoring of connected 4-20 mA measuring devices via a
Web browser.

 BA00053S
For details, see "Technical Information" TI00025S and Operating Instructions

Fieldgate FXA520 Gateway for the remote diagnostics and remote configuration of connected HART
measuring devices via a Web browser.

 For details, see "Technical Information" TI00025S and Operating Instructions


BA00051S

Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area.

 For details, see Operating Instructions BA01202S


Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area and the Ex area.

 For details, see Operating Instructions BA01202S


Service-specific accessories Accessories Description

Applicator Software for selecting and sizing Endress+Hauser measuring devices:


• Calculation of all the necessary data for identifying the optimum flowmeter: e.g.
nominal diameter, pressure loss, accuracy or process connections.
• Graphic illustration of the calculation results
Administration, documentation and access to all project-related data and
parameters throughout the entire life cycle of a project.
Applicator is available:
• Via the Internet: https://wapps.endress.com/applicator
• On CD-ROM for local PC installation.

W@M Life cycle management for your plant


W@M supports you with a wide range of software applications over the entire
process: from planning and procurement, to the installation, commissioning and
operation of the measuring devices. All the relevant device information, such as
the device status, spare parts and device-specific documentation, is available for
every device over the entire life cycle.
The application already contains the data of your Endress+Hauser device. Endress
+Hauser also takes care of maintaining and updating the data records.
W@M is available:
• Via the Internet: www.endress.com/lifecyclemanagement
• On CD-ROM for local PC installation.

FieldCare FDT-based plant asset management tool from Endress+Hauser.


It can configure all smart field units in your system and helps you manage them. By
using the status information, it is also a simple but effective way of checking their
status and condition.

 For details, see Operating Instructions BA00027S and BA00059S


Commubox FXA291 Connects Endress+Hauser field devices with a CDI interface (= Endress+Hauser
Common Data Interface) and the USB port of a computer or laptop.

 For details, see "Technical Information" TI00405C

Endress+Hauser 83
Proline Promag L 400

System components Accessories Description

Memograph M graphic The Memograph M graphic display recorder provides information on all relevant
display recorder measured variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on a SD card or USB stick.

 BA00247R
For details, see "Technical Information" TI00133R and Operating Instructions

Documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• The CD-ROM provided for the device (depending on the device version, the CD-ROM might
not be part of the delivery!)
• The W@M Device Viewer : Enter the serial number from the nameplate
(www.endress.com/deviceviewer)
• The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.

Standard documentation Brief Operating Instructions

Measuring device Documentation code

Promag L 400 KA01113D

Operating Instructions

Measuring device Documentation code

HART PROFIBUS DP Modbus RS485 EtherNet/IP

Promag L 400 BA01062D BA01233D BA01230D BA01213D

Supplementary device- Special documentation


dependent documentation
Contents Documentation code

Modbus RS485 Register Information SD01379D

Heartbeat Technology SD01183D

Installation Instructions

Contents Documentation code

Installation Instructions for spare part sets Specified for each individual accessory

Registered trademarks
HART®
Registered trademark of the HART Communication Foundation, Austin, USA
PROFIBUS®
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
Modbus®
Registered trademark of SCHNEIDER AUTOMATION, INC.
EtherNet/IPTM
Trademark of ODVA, Inc.

84 Endress+Hauser
Proline Promag L 400

Microsoft®
Registered trademark of the Microsoft Corporation, Redmond, Washington, USA
Applicator®, FieldCare®, Field XpertTM, HistoROM®, Heartbeat TechnologyTM
Registered or registration-pending trademarks of the Endress+Hauser Group

Endress+Hauser 85
www.addresses.endress.com
TI01046D/06/EN/05.15 Products Solutions Services
71280405

Technical Information
Proline Promag W 400
Electromagnetic flowmeter

The flowmeter with integrated web server & sensor with EN ISO 12944
corrosion protection
Application Your benefits
• The measuring principle is practically independent of • For direct underground installation or permanent
pressure, density, temperature and viscosity underwater use
• The specialist for very demanding applications in the water • Safe, reliable long-term operation – robust and completely
and wastewater industry welded sensor
Device properties • Energy-saving flow measurement – no pressure loss due to
• International drinking water approvals cross-section constriction
• Degree of protection IP68 (Type 6P enclosure) • Maintenance-free – no moving parts
• Approved for custody transfer to MI‐001/OIML R49 • Safe operation – no need to open device thanks to touch
• Transmitter housing made of durable polycarbonate or control display, backlighting
aluminum • Time‐saving local operation without additional software and
• Same housing concept for compact/remote version hardware – integrated web server
• Integrated data logger for measured values monitoring • Integrated verification – Heartbeat Technology™
Proline Promag W 400

Table of contents

Document information . . . . . . . . . . . . . . . . . . . . . . . 4 Mechanical load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39


Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 40

Function and system design . . . . . . . . . . . . . . . . . . . 4 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40


Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Medium temperature range . . . . . . . . . . . . . . . . . . . . . . 40
Measuring system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Equipment architecture . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pressure-temperature ratings . . . . . . . . . . . . . . . . . . . . 40
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Pressure tightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Flow limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Pressure loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Vibrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operable flow range . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Input signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Mechanical construction . . . . . . . . . . . . . . . . . . . . 44
Dimensions in SI units . . . . . . . . . . . . . . . . . . . . . . . . . 44
Dimensions in US units . . . . . . . . . . . . . . . . . . . . . . . . . 65
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Measuring tube specification . . . . . . . . . . . . . . . . . . . . . 96
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Low flow cut off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Fitted electrodes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Process connections . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Surface roughness . . . . . . . . . . . . . . . . . . . . . . . . . . . 100

Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Pin assignment, device plug . . . . . . . . . . . . . . . . . . . . . . 22
Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Service interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Certificates and approvals . . . . . . . . . . . . . . . . . . 105
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . 27 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 C-Tick symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Drinking water approval . . . . . . . . . . . . . . . . . . . . . . . 105
Certification PROFIBUS . . . . . . . . . . . . . . . . . . . . . . . . 105
Modbus RS485 certification . . . . . . . . . . . . . . . . . . . . . 105
Performance characteristics . . . . . . . . . . . . . . . . . . 31
EtherNet/IP certification . . . . . . . . . . . . . . . . . . . . . . . 106
Reference operating conditions . . . . . . . . . . . . . . . . . . . 31
Measuring instrument approval . . . . . . . . . . . . . . . . . . 106
Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . 32
Other standards and guidelines . . . . . . . . . . . . . . . . . . 106
Repeatability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Influence of ambient temperature . . . . . . . . . . . . . . . . . 33
Ordering information . . . . . . . . . . . . . . . . . . . . . . 106
Product generation index . . . . . . . . . . . . . . . . . . . . . . 107
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Mounting location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Application packages . . . . . . . . . . . . . . . . . . . . . . 107
Inlet and outlet runs . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Diagnostics functions . . . . . . . . . . . . . . . . . . . . . . . . . 107
Length of connecting cable . . . . . . . . . . . . . . . . . . . . . . 36 Heartbeat Technology . . . . . . . . . . . . . . . . . . . . . . . . 107
Installing the wall-mount housing . . . . . . . . . . . . . . . . . 37
Special mounting instructions . . . . . . . . . . . . . . . . . . . . 37 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 108
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Communication-specific accessories . . . . . . . . . . . . . . . 108
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 38 Service-specific accessories . . . . . . . . . . . . . . . . . . . . . 109
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . 39 System components . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Atmosphere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Shock resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . 110
Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

2 Endress+Hauser
Proline Promag W 400

Supplementary device-dependent documentation . . . . . . 110

Registered trademarks . . . . . . . . . . . . . . . . . . . . . 110

Endress+Hauser 3
Proline Promag W 400

Document information
Symbols used Electrical symbols

Symbol Meaning Symbol Meaning

Direct current Alternating current

Direct current and alternating current Ground connection


A grounded terminal which, as far as
the operator is concerned, is
grounded via a grounding system.

Protective ground connection Equipotential connection


A terminal which must be connected A connection that has to be connected
to ground prior to establishing any to the plant grounding system: This
other connections. may be a potential equalization line
or a star grounding system depending
on national or company codes of
practice.

Symbols for certain types of information

Symbol Meaning

Permitted
Procedures, processes or actions that are permitted.

Preferred
Procedures, processes or actions that are preferred.

Forbidden
Procedures, processes or actions that are forbidden.

Tip
Indicates additional information.

Reference to documentation

Reference to page

Reference to graphic

Visual inspection

Symbols in graphics

Symbol Meaning Symbol Meaning

1, 2, 3,... Item numbers , , … Series of steps

A, B, C, ... Views A-A, B-B, C-C, ... Sections

Hazardous area Safe area (non-hazardous area)


- .
Flow direction

Function and system design


Measuring principle Following Faraday's law of magnetic induction, a voltage is induced in a conductor moving through a
magnetic field.

4 Endress+Hauser
Proline Promag W 400

Ue
I

A0017035

Ue Induced voltage
B Magnetic induction (magnetic field)
L Electrode spacing
I Current
v Flow velocity

In the electromagnetic measuring principle, the flowing medium is the moving conductor. The
voltage induced (Ue) is proportional to the flow velocity (v) and is supplied to the amplifier by means
of two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DC
magnetic field is created through a switched direct current of alternating polarity.
Formulae for calculation
• Induced voltage Ue = B · L · v
• Volume flow  Q = A · v

Endress+Hauser 5
Proline Promag W 400

Measuring system The device consists of a transmitter and a sensor.


Two device versions are available:
• Compact version - transmitter and sensor form a mechanical unit.
• Remote version - transmitter and sensor are mounted in separate locations.

Transmitter

Promag 400 Device versions and materials


• Compact version: compact housing
– Polycarbonate plastic
– Aluminum, AlSi10Mg, coated
• Remote version: wall-mount housing
– Polycarbonate plastic
– Aluminum, AlSi10Mg, coated
Configuration:
A0017117
• External operation via four-line, illuminated local display with touch
control and guided menus ("Make-it-run" wizards) for applications
• Via operating tools (e.g. FieldCare)
• Via Web browser (e.g. Microsoft Internet Explorer)
• Also for device version with EtherNet/IP output:
– Via Add-on Profile Level 3 for automation system from Rockwell
Automation
– Via Electronic Data Sheet (EDS)
• Also for device version with PROFIBUS DP output:
Via PDM driver for Siemens automation system

Sensor

Promag W • Nominal diameter range: DN 25 to 2000 (1 to 78")


• Materials:
Fixed flange: DN 25 to 300 (1 to – Sensor housing: aluminum, AlSi10Mg, coated; carbon steel with
12") protective varnish
– Sensor connection housing (standard): aluminum, AlSi10Mg, coated
Sensor connection housing (option): polycarbonate
– Measuring tubes 1):
DN 25 to 300 (1 to 12"): stainless steel, 1.4301/1.4306/304/304L
DN 350 to 2000 (14 to 78"): stainless steel, 1.4301/304
– Liner: hard rubber, polyurethane
– Electrodes: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS
A0017040 N06022); tantalum
– Process connections:
Fixed flange: DN 25 to 300 (1 to Stainless steel, 1.4404/1.4571/F316L
12") Carbon steel, A105/A181/A350LF2/A515(70)/FE410WB/
S235JRG2/S235J+N/S275JR/P235GH/P250GH/P265GH
– Seals: as per DIN EN 1514-1
– Ground disks: stainless steel, 1.4435 (316L); Alloy C22, 2.4602
(UNS N06022); tantalum

A0022673

Fixed flange: DN 350 to 2000 (14


to 78")

A0017041

1) For carbon steel flange material with Al/Zn protective coating (DN 25 to 300 (1 to 12")), protective varnish
(IP68) (DN 50 to 300 (2 to 12")) or protective varnish ≥ DN 350 (14")

6 Endress+Hauser
Proline Promag W 400

Equipment architecture

1 2 3 4

5
A0021560

1 Possibilities for integrating measuring devices into a system


1 Control system (e.g. PLC)
2 EtherNet/IP
3 PROFIBUS DP
4 Modbus RS485
5 4-20 mA HART, pulse/frequency/switch output
6 Non-hazardous area
7 Non-hazardous area and Zone 2/Div. 2

Safety IT security
We only provide a warranty if the device is installed and used as described in the Operating
Instructions. The device is equipped with security mechanisms to protect it against any inadvertent
changes to the device settings.
IT security measures in line with operators' security standards and designed to provide additional
protection for the device and device data transfer must be implemented by the operators themselves.

Input
Measured variable Direct measured variables
• Volume flow (proportional to induced voltage)
• Electrical conductivity
In custody transfer: only volume flow

Calculated measured variables


Mass flow

Measuring range Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy
Electrical conductivity: 5 to 10 000 µS/cm

Flow characteristic values in SI units


Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[mm] [in] [m3/h] [m3/h] [m3] [m3/h]

25 1 9 to 300 dm3/min 75 dm3/min 0.5 dm3 1 dm3/min

32 – 15 to 500 dm3/min 125 dm3/min 1 dm3 2 dm3/min

Endress+Hauser 7
Proline Promag W 400

Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[mm] [in] [m3/h] [m3/h] [m3] [m3/h]

40 1½ 25 to 700 dm3/min 200 dm3/min 1.5 dm3 3 dm3/min

50 2 35 to 1 100 dm3/min 300 dm3/min 2.5 dm3 5 dm3/min

65 – 60 to 2 000 dm3/min 500 dm3/min 5 dm3 8 dm3/min

80 3 90 to 3 000 dm3/min 750 dm3/min 5 dm3 12 dm3/min

100 4 145 to 4 700 dm3/min 1 200 dm3/min 10 dm3 20 dm3/min

125 – 220 to 7 500 dm3/min 1 850 dm3/min 15 dm3 30 dm3/min

150 6 20 to 600 150 0.025 2.5

200 8 35 to 1 100 300 0.05 5

250 10 55 to 1 700 500 0.05 7.5

300 12 80 to 2 400 750 0.1 10

350 14 110 to 3 300 1 000 0.1 15

375 15 140 to 4 200 1 200 0.15 20

400 16 140 to 4 200 1 200 0.15 20

450 18 180 to 5 400 1 500 0.25 25

500 20 220 to 6 600 2 000 0.25 30

600 24 310 to 9 600 2 500 0.3 40

700 28 420 to 13 500 3 500 0.5 50

750 30 480 to 15 000 4 000 0.5 60

800 32 550 to 18 000 4 500 0.75 75

900 36 690 to 22 500 6 000 0.75 100

1 000 40 850 to 28 000 7 000 1 125

– 42 950 to 30 000 8 000 1 125

1 200 48 1 250 to 40 000 10 000 1.5 150

– 54 1 550 to 50 000 13 000 1.5 200

1 400 – 1 700 to 55 000 14 000 2 225

– 60 1 950 to 60 000 16 000 2 250

1 600 – 2 200 to 70 000 18 000 2.5 300

– 66 2 500 to 80 000 20 500 2.5 325

1 800 72 2 800 to 90 000 23 000 3 350

– 78 3 300 to 100 000 28 500 3.5 450

2 000 – 3 400 to 110 000 28 500 3.5 450

8 Endress+Hauser
Proline Promag W 400

Flow characteristic values in US units


Nominal Recommended
Factory settings
diameter flow

Full scale value current


Min./max. full scale value Pulse value Low flow cut off
output
(v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s)
(v ~ 2.5 m/s)

[in] [mm] [gal/min] [gal/min] [gal] [gal/min]

1 25 2.5 to 80 18 0.2 0.25

– 32 4 to 130 30 0.2 0.5

1½ 40 7 to 190 50 0.5 0.75

2 50 10 to 300 75 0.5 1.25

– 65 16 to 500 130 1 2

3 80 24 to 800 200 2 2.5

4 100 40 to 1 250 300 2 4

– 125 60 to 1 950 450 5 7

6 150 90 to 2 650 600 5 12

8 200 155 to 4 850 1 200 10 15

10 250 250 to 7 500 1 500 15 30

12 300 350 to 10 600 2 400 25 45

14 350 500 to 15 000 3 600 30 60

15 375 600 to 19 000 4 800 50 60

16 400 600 to 19 000 4 800 50 60

18 450 800 to 24 000 6 000 50 90

20 500 1 000 to 30 000 7 500 75 120

24 600 1 400 to 44 000 10 500 100 180

28 700 1 900 to 60 000 13 500 125 210

30 750 2 150 to 67 000 16 500 150 270

32 800 2 450 to 80 000 19 500 200 300

36 900 3 100 to 100 000 24 000 225 360

40 1 000 3 800 to 125 000 30 000 250 480

42 – 4 200 to 135 000 33 000 250 600

48 1 200 5 500 to 175 000 42 000 400 600

54 – 9 to 300 Mgal/d 75 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

– 1 400 10 to 340 Mgal/d 85 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

60 – 12 to 380 Mgal/d 95 Mgal/d 0.0005 Mgal/d 1.3 Mgal/d

– 1 600 13 to 450 Mgal/d 110 Mgal/d 0.0008 Mgal/d 1.7 Mgal/d

66 – 14 to 500 Mgal/d 120 Mgal/d 0.0008 Mgal/d 2.2 Mgal/d

72 1 800 16 to 570 Mgal/d 140 Mgal/d 0.0008 Mgal/d 2.6 Mgal/d

78 – 18 to 650 Mgal/d 175 Mgal/d 0.0010 Mgal/d 3.0 Mgal/d

– 2 000 20 to 700 Mgal/d 175 Mgal/d 0.0010 Mgal/d 2.9 Mgal/d

To calculate the measuring range, use the Applicator sizing tool →  109

Endress+Hauser 9
Proline Promag W 400

Recommended measuring range


"Flow limit" section →  43
For custody transfer, the applicable approval determines the permitted measuring range and
the pulse value.

Operable flow range Over 1000 : 1


For custody transfer, the operable flow range is 100 : 1 to 250 : 1, depending on the nominal
diameter. Further details are specified by the applicable approval.

Input signal External measured values


Various pressure transmitters and temperature measuring devices can be ordered from Endress
+Hauser: see "Accessories" section →  109
It is recommended to read in external measured values to calculate the following measured variables:
Corrected volume flow

HART protocol
The measured values are written from the automation system to the measuring device via the HART
protocol. The pressure transmitter must support the following protocol-specific functions:
• HART protocol
• Burst mode

Fieldbuses
The measured values can be written from the automation system to the measuring via:
• PROFIBUS DP
• Modbus RS485
• EtherNet/IP

Status input

Maximum input values • DC 30 V


• 6 mA

Response time Adjustable: 5 to 200 ms

Input signal level • Low signal: DC –3 to +5 V


• High signal: DC 12 to 30 V

Assignable functions • Off


• Reset totalizers 1-3 separately
• Reset all totalizers
• Flow override

Output
Output signal Current output

Current output Can be set as:


• 4-20 mA NAMUR
• 4-20 mA US
• 4-20 mA HART
• 0-20 mA

Maximum output values • DC 24 V (no flow)


• 22.5 mA

Load 0 to 700 Ω

Resolution 0.5 µA

10 Endress+Hauser
Proline Promag W 400

Damping Adjustable: 0.07 to 999 s

Assignable measured • Volume flow


variables • Mass flow
• Flow velocity
• Conductivity
• Electronic temperature

Pulse/frequency/switch output

Function • With the order code for "Output; Input", option H: output 2 can be set as a pulse
or frequency output
• With the order code for "Output; Input", option I: output 2 and 3 can be set as a
pulse, frequency or switch output
• With the order code for "Output; Input", option J: output 2 firmly assigned as
certified pulse output

Version Passive, open collector

Maximum input values • DC 30 V


• 250 mA

Voltage drop For 25 mA: ≤ DC 2 V

Pulse output

Pulse width Adjustable: 0.05 to 2 000 ms

Maximum pulse rate 10 000 Impulse/s

Pulse value Adjustable

Assignable measured • Volume flow


variables • Mass flow

Frequency output

Output frequency Adjustable: 0 to 12 500 Hz

Damping Adjustable: 0 to 999 s

Pulse/pause ratio 1:1

Assignable measured • Volume flow


variables • Mass flow
• Conductivity
• Flow velocity
• Electronic temperature

Switch output

Switching behavior Binary, conductive or non-conductive

Switching delay Adjustable: 0 to 100 s

Number of switching Unlimited


cycles

Assignable functions • Off


• On
• Diagnostic behavior
• Limit value:
– Off
– Volume flow
– Mass flow
– Conductivity
– Flow velocity
– Totalizer 1-3
– Electronic temperature
• Flow direction monitoring
• Status
– Empty pipe detection
– Low flow cut off

Endress+Hauser 11
Proline Promag W 400

PROFIBUS DP

Signal encoding NRZ code

Data transfer 9.6 kBaud…12 MBaud

Modbus RS485

Physical interface In accordance with EIA/TIA-485-A standard

Terminating resistor Integrated, can be activated via DIP switch on the transmitter electronics module

EtherNet/IP

Standards In accordance with IEEE 802.3

Signal on alarm Depending on the interface, failure information is displayed as follows:

Current output

4-20 mA
Failure mode Selectable (as per NAMUR recommendation NE 43):
• Minimum value: 3.6 mA
• Maximum value: 22 mA
• Defined value: 3.59 to 22.5 mA
• Actual value
• Last valid value

0-20 mA
Failure mode Choose from:
• Maximum alarm: 22 mA
• Defined value: 0 to 22.5 mA

HART
Device diagnostics Device condition can be read out via HART Command 48

Pulse/frequency/switch output

Pulse output
Failure mode Choose from:
• Actual value
• No pulses

Frequency output
Failure mode Choose from:
• Actual value
• 0 Hz
• Defined value: 0 to 12 500 Hz

Switch output
Failure mode Choose from:
• Current status
• Open
• Closed

12 Endress+Hauser
Proline Promag W 400

PROFIBUS DP

Status and alarm Diagnostics in accordance with PROFIBUS PA Profile 3.02


messages

Modbus RS485

Failure mode Choose from:


• NaN value instead of current value
• Last valid value

EtherNet/IP

Device diagnostics Device condition can be read out in Input Assembly

Local display

Plain text display With information on cause and remedial measures

Backlight Red backlighting indicates a device error.

Status signal as per NAMUR recommendation NE 107

Operating tool
• Via digital communication:
– HART protocol
– PROFIBUS DP
– Modbus RS485
– EtherNet/IP
• Via service interface

Plain text display With information on cause and remedial measures

Additional information on remote operation →  101

Web browser

Plain text display With information on cause and remedial measures

Light emitting diodes (LED)

Status information Status indicated by various light emitting diodes


The following information is displayed depending on the device version:
• Supply voltage active
• Data transmission active
• Device alarm/error has occurred
• EtherNet/IP network available
• EtherNet/IP connection established

Low flow cut off The switch points for low flow cut off are user-selectable.

Galvanic isolation The following connections are galvanically isolated from each other:
• Inputs
• Outputs
• Power supply

Endress+Hauser 13
Proline Promag W 400

Protocol-specific data HART

Manufacturer ID 0x11

Device type ID 0x67

HART protocol revision 7

Device description files Information and files under:


(DTM, DD) www.endress.com

HART load Min. 250 Ω

Dynamic variables Read out the dynamic variables: HART command 3


The measured variables can be freely assigned to the dynamic variables.
Measured variables for PV (primary dynamic variable)
• Off
• Volume flow
• Mass flow
• Conductivity
• Flow velocity
• Electronic temperature
Measured variables for SV, TV, QV (secondary, tertiary and quaternary
dynamic variable)
• Volume flow
• Mass flow
• Conductivity
• Flow velocity
• Electronic temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3

Device variables Read out the device variables: HART command 9


The device variables are permanently assigned.
A maximum of 8 device variables can be transmitted:
• 0 = volume flow
• 1 = mass flow
• 2 = conductivity
• 3 = flow velocity
• 4 = electronic temperature
• 5 = totalizer 1
• 6 = totalizer 2
• 7 = totalizer 3

PROFIBUS DP

Manufacturer ID 0x11

Ident number 0x1562

Profile version 3.02

Device description files (GSD, Information and files under:


DTM, DD) • www.endress.com
• www.profibus.org

Output values Analog input 1 to 4


(from measuring device to • Mass flow
automation system) • Volume flow
• Flow velocity
• Conductivity
• Electronic temperature
Digital input 1 to 2
• Empty pipe detection
• Low flow cut off
• Verification status
Totalizer 1 to 3
• Mass flow
• Volume flow

14 Endress+Hauser
Proline Promag W 400

Input values Analog output 1 (fixed assignment)


(from automation system to External density
measuring device) Digital output 1 to 2 (fixed assignment)
• Digital output 1: switch positive zero return on/off
• Digital output 2: start verification
Totalizer 1 to 3
• Totalize
• Reset and hold
• Preset and hold
• Stop
• Operating mode configuration:
– Net flow total
– Forward flow total
– Reverse flow total

Supported functions • Identification & Maintenance


Simplest device identification on the part of the control system and
nameplate
• PROFIBUS upload/download
Reading and writing parameters is up to ten times faster with PROFIBUS
upload/download
• Condensed status
Simplest and self-explanatory diagnostic information by categorizing
diagnostic messages that occur

Configuration of the device • DIP switches on the I/O electronics module


address • Via operating tools (e.g. FieldCare)

Modbus RS485

Protocol Modbus Applications Protocol Specification V1.1

Device type Slave

Slave address range 1 to 247

Broadcast address range 0

Function codes • 03: Read holding register


• 04: Read input register
• 06: Write single registers
• 08: Diagnostics
• 16: Write multiple registers
• 23: Read/write multiple registers

Broadcast messages Supported by the following function codes:


• 06: Write single registers
• 16: Write multiple registers
• 23: Read/write multiple registers

Supported baud rate • 1 200 BAUD


• 2 400 BAUD
• 4 800 BAUD
• 9 600 BAUD
• 19 200 BAUD
• 38 400 BAUD
• 57 600 BAUD
• 115 200 BAUD

Data transfer mode • ASCII


• RTU

Data access Each device parameter can be accessed via Modbus RS485.

 For Modbus register information

Endress+Hauser 15
Proline Promag W 400

EtherNet/IP

Protocol • The CIP Networks Library Volume 1: Common Industrial Protocol


• The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP

Communication type • 10Base-T


• 100Base-TX

Device profile Generic device (product type: 0x2B)

Manufacturer ID 0x49E

Device type ID 0x1067

Baud rates Automatic ¹⁰⁄₁₀₀ Mbit with half-duplex and full-duplex detection

Polarity Auto-polarity for automatic correction of crossed TxD and RxD pairs

Supported CIP connections Max. 3 connections

Explicit connections Max. 6 connections

I/O connections Max. 6 connections (scanner)

Configuration options for • DIP switches on the electronics module for IP addressing
measuring device • Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• Electronic Data Sheet (EDS) integrated in the measuring device

Configuration of the EtherNet • Speed: 10 MBit, 100 MBit, auto (factory setting)
interface • Duplex: half-duplex, full-duplex, auto (factory setting)

Configuration of the device • DIP switches on the electronics module for IP addressing (last octet)
address • DHCP
• Manufacturer-specific software (FieldCare)
• Add-on Profile Level 3 for Rockwell Automation control systems
• Web browser
• EtherNet/IP tools, e.g. RSLinx (Rockwell Automation)

Device Level Ring (DLR) No

Fix Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 56

T → O configuration: 0x64 32

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 56

T → O configuration: 0x64 32

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x64 32

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x64 32

16 Endress+Hauser
Proline Promag W 400

Input Assembly • Current device diagnostics


• Volume flow
• Mass flow
• Conductivity
• Totalizer 1
• Totalizer 2
• Totalizer 3

Configurable Input

RPI 5 ms to 10 s (factory setting: 20 ms)

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0x66 56

T → O configuration: 0x65 88

Exclusive Owner Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0x66 56

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x68 398

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Input only Multicast Instance Size [byte]

Instance configuration: 0x69 -

O → T configuration: 0xC7 -

T → O configuration: 0x65 88

Configurable Input Assembly • Volume flow


• Mass flow
• Electronic temperature
• Conductivity
• Totalizer 1 to 3
• Flow velocity
• Volume flow unit
• Mass flow unit
• Temperature unit
• Conductivity unit
• Unit totalizer 1-3
• Flow velocity unit
• Verification result
• Verification status

 The range of options increases if the measuring device has one or


more application packages.

Fix Output

Output Assembly • Activation of reset totalizers 1-3


• Activation of reference density compensation
• Reset totalizers 1-3
• External density
• Density unit
• Activation verification
• Start verification

Endress+Hauser 17
Proline Promag W 400

Configuration

Configuration Assembly Only the most common configurations are listed below.
• Software write protection
• Mass flow unit
• Mass unit
• Volume flow unit
• Volume unit
• Density unit
• Conductivity
• Temperature unit
• Totalizer 1-3:
– Assignment
– Unit
– Operating mode
– Failure mode
• Alarm delay

Power supply
Terminal assignment Transmitter

0-20 mA/4-20 mA HART connection version with additional outputs and inputs
The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2 3

+ - + -
L+/L

L-/N

+ - + -

22 23 20 21

1 2 26 27 24 25

A0020424

1 Supply voltage
2 Output 1 (26/27) and output 2 (24/25)
3 Output 3 (22/23) and input 1 (20/21)

18 Endress+Hauser
Proline Promag W 400

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

Signal transmission 0-20 mA/4-20 mA HART with additional outputs and inputs
Order code for Terminal numbers
"Output" and
Output 1 Output 2 Output 3 Input
"Input"
26 (+) 27 (-) 24 (+) 25 (-) 22 (+) 23 (-) 20 (+) 21 (-)

Option H • 4-20 mA HART Pulse/frequency Switch output -


(active) output (passive)
• 0-20 mA (passive)
(active)

Option I • 4-20 mA HART Pulse/frequency/ Pulse/frequency/ Status input


(active) switch output switch output
• 0-20 mA (passive) (passive)
(active)

Option J • 4-20 mA HART Permanently Pulse/frequency/ Status input


(active) assigned switch output
• 0-20 mA Pulse output (passive)
(active) adjusted
(passive)

PROFIBUS DP connection version


The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2
L+/L

L-/N

B A

1 2 2627

A0020426

1 Supply voltage (wide range power unit)


2 PROFIBUS DP

Endress+Hauser 19
Proline Promag W 400

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

PROFIBUS DP signal transmission


Order code for "Output" and "Input" Terminal numbers

26 (RxD/TxD-P) 27 (RxD/TxD-N)

Option L B A

Order code for "Output":


Option L: PROFIBUS DP, for use in non-hazardous areas and Zone 2/div. 2

Modbus RS485 connection version


The sensor can be ordered with terminals.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

1 2
L+/L

L-/N

B A

1 2 2627

A0020427

1 Supply voltage (wide range power unit)


2 Modbus RS485

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

20 Endress+Hauser
Proline Promag W 400

Signal transmission Modbus RS485


Order code for "Output" and "Input" Terminal numbers

26 (+) 27 (-)

Option M B A

EtherNet/IP connection version


The sensor can be ordered with terminals or a device plug.

Connection methods available


Possible options for order code
Power "Electrical connection"
Outputs
supply

Terminals Terminals • Option A: coupling M20x1


• Option B: thread M20x1
• Option C: thread G ½"
• Option D: thread NPT ½"

Device plug Terminals • Option L: plug M12x1 + thread NPT ½"


• Option N: plug M12x1 + coupling M20
• Option P: plug M12x1 + thread G ½"
• Option U: plug M12x1 + thread M20

1 2
L+/L

L-/N

1 2

A0020428

1 Supply voltage (wide range power unit)


2 EtherNet/IP

Supply voltage
Order code for "Power supply" Terminal numbers

1 (L+/L) 2 (L-/N)

Option L AC100 to 240 V


(wide range power unit)
AC/DC24 V

EtherNet/IP signal transmission


Order code for "Output" Connection via

Option N EtherNet/IP connector

Endress+Hauser 21
Proline Promag W 400

Remote version

1 2

GND
E1
E2
S1

S2

E
S
A
6 5 7 8 4 37 36 42 41

1 n.c. n.c. n.c.


2
5 7 4 37 42 41

E1
E2
GND
E
B

A0020534

2 Remote version terminal assignment


A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable
n.c. Not connected, insulated cable shields

Terminal No. and cable colors: 6/5 = brown; 7/8 = white; 4 = green; 36/37 = yellow

Pin assignment, device plug Order codes for the M12x1 connectors, see the "Order code for electrical connection" column:
EtherNet/IP

EtherNet/IP

Device plug for signal transmission (device side)

2 Pin Assignment Coding Plug/socket

1 + Tx D Socket

2 + Rx
1 3
3 - Tx

4 - Rx
4
A0016812

 Recommended plug:
• Binder, series 763, part no. 99 3729 810 04
• Phoenix, part no. 1543223 SACC-M12MSD-4Q
• When using the device in a hazardous location, use a suitably certified plug.

Supply voltage Transmitter

Order code for "Power supply" Terminal voltage Frequency range

AC100 to 240 V 50/ 60 Hz, ±4 Hz


Option L
AC/DC24 V 50/ 60 Hz, ±4 Hz

Power consumption Order code for "Output" Maximum power consumption

Option H: 4-20mA HART, pulse/frequency/switch


30 VA/8 W
output, switch output

Option I: 4-20mA HART, 2 x pulse/frequency/switch


30 VA/8 W
output, status input

22 Endress+Hauser
Proline Promag W 400

Order code for "Output" Maximum power consumption

Option J: 4-20mA HART, certified pulse output, pulse/


30 VA/8 W
frequency/switch output, status input

Option L: PROFIBUS DP 30 VA/8 W

Option M: Modbus RS485 30 VA/8 W

Option N: EtherNet/IP 30 VA/8 W

Current consumption Transmitter

Order code for "Power supply" Maximum Maximum


Current consumption switch-on current

Option L: AC 100 to 240 V 145 mA 25 A (< 5 ms)

Option L: AC/DC 24 V 350 mA 27 A (< 5 ms)

Power supply failure • Totalizers stop at the last value measured.


• Configuration is retained in the plug-in memory (HistoROM DAT).
• Error messages (incl. total operated hours) are stored.

Electrical connection Connecting the transmitter

A B

1 2 2 1 2 2
A0017113

3 Supply voltage and signal transmission connection


A Compact version
B Remote version wall-mount housing
1 Cable entry for supply voltage
2 Cable entry for signal transmission

Remote version connection

Connecting cable

A B

1 2 1 2
A0017267

4 Connecting cable connection: electrode and coil current cable


A Transmitter wall-mount housing
B Sensor connection housing
1 Electrode cable
2 Coil current cable

• Fix the cable run or route it in an armored conduit.


Cable movements can influence the measuring signal especially in the case of low fluid
conductivities.
• Route the cable well clear of electrical machines and switching elements.
• Ensure potential equalization between sensor and transmitter .

Endress+Hauser 23
Proline Promag W 400

Connection examples

Current output 4-20 mA HART

1 2 3
4...20 mA
+ +
– 6
_

4 5
A0016800

5 Connection example for 4-20 mA HART current output (active)


1 Automation system with current input (e.g. PLC)
2 Cable shield, observe cable specifications →  29
3 Connection for HART operating devices
4 Resistor for HART communication (≥ 250 Ω): observe maximum load
5 Analog display unit: observe maximum load
6 Transmitter

Current output 4-20 mA

0/4...20 mA
+
+
– 3
_

2
A0017162

6 Connection example for 0-20 mA current output (active) and 4-20 mA current output (active)
1 Automation system with current input (e.g. PLC)
2 Analog display unit: observe maximum load
3 Transmitter

Pulse/frequency output

1 2
– +

_ +
– 3
+
12345
A0016801

7 Connection example for pulse/frequency output (passive)


1 Automation system with pulse/frequency input (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

24 Endress+Hauser
Proline Promag W 400

Switch output

1 2
_ +
_
+
_ 3
+

A0016802

8 Connection example for switch output (passive)


1 Automation system with switch input (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

PROFIBUS DP

1 2

A A
3
B
B

A
3
B

A0021429

9 Connection example for PROFIBUS DP, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  29
3 Transmitter

If baud rates > 1.5 MBaud an EMC cable entry must be used and the cable shield must continue
as far as the terminal wherever possible.

Endress+Hauser 25
Proline Promag W 400

Modbus RS485

1 2 3

A A
4
B
B

A
4
B

A0016803

 10 Connection example for Modbus RS485, non-hazardous area and Zone 2/Div. 2
1 Control system (e.g. PLC)
2 Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable
specifications →  29
3 Distribution box
4 Transmitter

EtherNet/IP

1 2 3 4

A0016805

 11 Connection example for EtherNet/IP


1 Control system (e.g. PLC)
2 Ethernet switch
3 Observe cable specifications →  30
4 Device plug
5 Transmitter

Status input

1 2
+ _
+
_
+ 3
_

A0017163

 12 Connection example for status input


1 Automation system with status output (e.g. PLC)
2 Power supply
3 Transmitter: observe input values

26 Endress+Hauser
Proline Promag W 400

Potential equalization Requirements


Please consider the following to ensure correct measurement:
• Same electrical potential for the fluid and sensor
• Remote version: same electrical potential for the sensor and transmitter
• Company-internal grounding concepts
• Pipe material and grounding

Connection examples for standard situations

Metal, grounded pipe

A0016315

 13 Potential equalization via measuring tube

Connection example in special situations

Unlined and ungrounded metal pipe


This connection method also applies in situations where:
• The customary potential equalization is not used
• Equalizing currents are present

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

DN ≤ 300 DN ≥ 350

A0016317

 14 Potential equalization via ground terminal and pipe flanges

Note the following when installing:


• Connect both sensor flanges to the pipe flange via a ground cable and ground them.
• Connect the connection housing of the transmitter or sensor to ground potential by means of the
ground terminal provided for the purpose. To mount the ground cable:
– If DN ≤ 300 (12"): Mount the ground cable directly on the conductive flange coating of the
sensor with the flange screws.
– If DN ≥ 350 (14"): Mount the ground cable directly on the metal transport bracket.
For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The necessary ground cable can be ordered from Endress+Hauser .

Plastic pipe or pipe with insulating liner


This connection method also applies in situations where:
• The customary potential equalization is not used
• Equalizing currents are present

Endress+Hauser 27
Proline Promag W 400

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

A0016318

 15 Potential equalization via ground terminal and ground disks

Note the following when installing:


The ground disks must be connected to the ground terminal via the ground cable and be connected
to ground potential.
For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The ground cable and ground disks can be ordered from Endress+Hauser →  108.

Pipe with a cathodic protection unit


This connection method is only used if the following two conditions are met:
• Metal pipe without liner or pipe with electrically conductive liner
• Cathodic protection is integrated in the personal protection equipment

Ground cable Copper wire, at least6 mm2 (0.0093 in2)

+

A0016319

Prerequisite: The sensor is installed in the pipe in a way that provides electrical insulation.
1. Connect the two flanges of the pipe to one another via a ground cable.
2. Guide the shield of the signal lines through a capacitor.
3. Connect the measuring device to the power supply such that it is floating in relation to the
protective ground (isolation transformer).

For remote device versions, the ground terminal in the example always refers to the sensor and
not to the transmitter.
The necessary ground cable can be ordered from Endress+Hauser .

Terminals Transmitter
• Supply voltage cable: plug-in spring terminals for wire cross-sections
0.5 to 2.5 mm2 (20 to 14 AWG)
• Signal cable: plug-in spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
• Electrode cable: spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
• Coil current cable: spring terminals for wire cross-sections 0.5 to 2.5 mm2 (20 to 14 AWG)
Sensor connection housing
Spring terminals for wire cross-sections0.5 to 2.5 mm2 (20 to 14 AWG)

28 Endress+Hauser
Proline Promag W 400

Cable entries Cable entry thread


• M20 x 1.5
• Via adapter:
– NPT ½"
– G ½"
Cable gland
• For standard cable: M20 × 1.5 with cable 6 to 12 mm (0.24 to 0.47 in)
• For reinforced cable: M20 × 1.5 with cable 9.5 to 16 mm (0.37 to 0.63 in)
If metal cable entries are used, use a grounding plate.

Cable specification Permitted temperature range


• –40 °C (–40 °F) to +80 °C (+176 °F)
• Minimum requirement: cable temperature range ≥ ambient temperature +20 K

Power supply cable


Standard installation cable is sufficient.

Signal cable

Current output
• For 0-20 mA and 4-20 mA: standard installation cable is sufficient.
• For 4-20 mA HART: Shielded cable recommended. Observe grounding concept of the plant.

Pulse/frequency/switch output
Standard installation cable is sufficient.

Status input
Standard installation cable is sufficient.

PROFIBUS DP
The IEC 61158 standard specifies two types of cable (A and B) for the bus line which can be used for
every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance <30 pF/m

Wire cross-section >0.34 mm2 (22 AWG)

Cable type Twisted pairs

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

Modbus RS485
The EIA/TIA-485 standard specifies two types of cable (A and B) for the bus line which can be used
for every transmission rate. Cable type A is recommended.

Cable type A

Characteristic impedance 135 to 165 Ω at a measuring frequency of 3 to 20 MHz

Cable capacitance <30 pF/m

Wire cross-section >0.34 mm2 (22 AWG)

Cable type Twisted pairs

Endress+Hauser 29
Proline Promag W 400

Loop resistance ≤110 Ω/km

Signal damping Max. 9 dB over the entire length of the cable cross-section

Shielding Copper braided shielding or braided shielding with foil shield. When grounding
the cable shield, observe the grounding concept of the plant.

EtherNet/IP
The standard ANSI/TIA/EIA-568-B.2 Annex specifies CAT 5 as the minimum category for a cable
used for EtherNet/IP. CAT 5e and CAT 6 are recommended.
For more information on planning and installing EtherNet/IP networks, please refer to the
"Media Planning and Installation Manual. EtherNet/IP" of ODVA Organization.

Connecting cable for remote version

Electrode cable

Standard cable 3 ×0.38 mm2 (20 AWG) with common, braided copper shield ( ~7 mm (0.28 in)
and individual shielded cores

Cable for empty pipe 4 ×0.38 mm2 (20 AWG) with common, braided copper shield ( ~7 mm (0.28 in)
detection (EPD) and individual shielded cores

Conductor resistance ≤50 Ω/km (0.015 Ω/ft)

Capacitance: core/shield ≤420 pF/m (128 pF/ft)

Operating temperature –20 to +80 °C (–68 to +176 °F)

Coil current cable

Standard cable 2 ×0.75 mm2 (18 AWG) with common, braided copper shield ( ~ 7 mm (0.28"))
and individually shielded cores

Conductor resistance ≤37 Ω/km (0.011 Ω/ft)

Capacitance: core/core, ≤120 pF/m (37 pF/ft)


shield grounded

Operating temperature –20 to +80 °C (–68 to +176 °F)

Test voltage for cable ≤ AC 1433 V r.m.s. 50/60 Hz or ≥ DC 2026 V


insulation

30 Endress+Hauser
Proline Promag W 400

1
2
3
4
5
6
7
a b
A0003194

 16 Cable cross-section
a Electrode cable
b Coil current cable
1 Core
2 Core insulation
3 Core shield
4 Core jacket
5 Core reinforcement
6 Cable shield
7 Outer jacket

A connecting cable can be ordered from Endress+Hauser for IP68:


• Pre-terminated cables that are already connected to the sensor.
• Pre-terminated cables, where the cables are connected by the customer onsite (incl. tools for
sealing the connection compartment)

Reinforced connecting cables


Reinforced connecting cables with an additional, reinforcing metal braid should be used for:
• When laying the cable directly in the ground
• Where there is a risk of damage from rodents
• If using the device below IP68 degree of protection
Reinforced connecting cables with an additional, reinforcing metal braid can be ordered from
Endress+Hauser .

Operation in zones of severe electrical interference


The measuring system meets the general safety requirements →  106 and EMC specifications
→  40.
Grounding is by means of the ground terminal provided for the purpose inside the connection
housing. The stripped and twisted lengths of cable shield to the ground terminal must be as short as
possible.

Performance characteristics
Reference operating In accordance with DIN EN 29104
conditions • Medium temperature: +28 ± 2 °C (+82 ± 4 °F)
• Ambient temperature: +22 ± 2 °C (+72 ± 4 °F)
• Warm-up period:30 min
Installation
• Inlet run > 10 × DN
• Outlet run > 5 × DN
• Sensor and transmitter grounded.
• The sensor is centered in the pipe.
No special requirements must be observed at the inlet and outlet runs to keep within the in-
service maximum permissible errors for custody transfer.
To calculate the measuring range, use the Applicator sizing tool →  109

Endress+Hauser 31
Proline Promag W 400

Maximum measured error Error limits under reference operating conditions


o.r. = of reading
Volume flow
• ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
• Optional: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Fluctuations in the supply voltage do not have any effect within the specified range.

[%]
2.5
2.0
0.5 %
1.5
0.2 %
1.0
0.5
0
0 1 2 4 6 8 10 [m/s]
v
0 5 10 15 20 25 30 32 [ft/s]
A0005531

 17 Maximum measured error in % o.r.

[%]
2.5
2.0
0.5 %
1.5
0.2 %
1.0
0.5
0
0 10 [m/s]
v
v0.5 32 [ft/s]
v0.2
A0017051

 18 Flat Spec in % o.r.

Flat Spec flow values0.5 %


Nominal diameter v0.5

[mm] [in] [m/s] [ft/s]

25 to 600 1 to 24 0.5 1.64

Flat Spec flow values0.2 %


Nominal diameter v0.2

[mm] [in] [m/s] [ft/s]

25 to 600 1 to 24 1.5 4.92

Electrical conductivity
Max. measured error not specified.

32 Endress+Hauser
Proline Promag W 400

Accuracy of outputs
o.r. = of reading
The outputs have the following base accuracy specifications.

Current output

Accuracy Max. ±5 µA

Pulse/frequency output

Accuracy Max. ±50 ppm o.r. (across the complete ambient temperature range)

Repeatability o.r. = of reading


Volume flow
max. ±0.1 % o.r. ± 0.5 mm/s (0.02 in/s)
Electrical conductivity
Max. ±5 % o.r.

Influence of ambient o.r. = of reading


temperature
Current output

Temperature coefficient Max. ±0.005% o.r./°C

Pulse/frequency output

Temperature coefficient No additional effect. Included in accuracy.

Installation
No special measures such as supports are necessary. External forces are absorbed by the construction
of the device.

Mounting location
h

A0023343

Preferably install the sensor in an ascending pipe, and ensure a sufficient distance to the next pipe
elbow: h ≥ 2 × DN
To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid
the following mounting locations in the pipe:
• Highest point of a pipeline.
• Directly upstream of a free pipe outlet in a down pipe.

Endress+Hauser 33
Proline Promag W 400

Installation in down pipes


Install a siphon with a vent valve downstream of the sensor in down pipes whose length h ≥ 5 m
(16.4 ft). This precaution is to avoid low pressure and the consequent risk of damage to the
measuring tube. This measure also prevents the system losing prime.
For information on the liner's resistance to partial vacuum

1
2

h
A0017064

 19 Installation in a down pipe


1 Vent valve
2 Pipe siphon
h Length of down pipe

Installation in partially filled pipes


A partially filled pipe with a gradient necessitates a drain-type configuration. The empty pipe
detection (EPD) function offers additional protection by detecting empty or partially filled pipes.

N
×D
³2
N
×D
³5

A0017063

For heavy sensors DN ≥ 350 (14")

A0016276

Orientation The direction of the arrow on the sensor nameplate helps you to install the sensor according to the
flow direction (direction of medium flow through the piping).
An optimum orientation position helps avoid gas and air accumulations and deposits in the
measuring tube.
The measuring device also offers the empty pipe detection function to detect partially filled
measuring pipes in the event of outgassing fluids or variable process pressures.

34 Endress+Hauser
Proline Promag W 400

Vertical

A0015591

Optimum for self-emptying pipe systems and for use in conjunction with empty pipe detection.

Horizontal

2 2

A0016260

1 EPD electrode for empty pipe detection


2 Measuring electrodes for signal detection
3 Reference electrode for potential equalization

• The measuring electrode plane must be horizontal. This prevents brief insulation of the two
measuring electrodes by entrained air bubbles.
• Empty pipe detection only works if the transmitter housing is pointing upwards as otherwise
there is no guarantee that the empty pipe detection function will actually respond to a
partially filled or empty measuring tube.

Inlet and outlet runs If possible, install the sensor upstream from fittings such as valves, T-pieces or elbows.
Observe the following inlet and outlet runs to comply with accuracy specifications:

≥ 5 × DN ≥ 2 × DN

A0016275

To keep within the in-service maximum permissible errors for custody transfer no additional
requirements apply with regard to the graphic illustrated above.

Adapters Suitable adapters to DIN EN 545 (double-flange reducers) can be used to install the sensor in larger-
diameter pipes. The resultant increase in the rate of flow improves measuring accuracy with very
slow-moving fluids.
The nomogram shown here can be used to calculate the pressure loss caused by reducers and
expanders:
• Calculate the ratio of the diameters d/D.
• From the nomogram read off the pressure loss as a function of flow velocity (downstream from
the reduction) and the d/D ratio.
The nomogram only applies to liquids with a viscosity similar to that of water.

Endress+Hauser 35
Proline Promag W 400

[mbar] 100

8 m/s
7 m/s

6 m/s
10
5 m/s

max. 8° 4 m/s

3 m/s
d D
2 m/s
1

1 m/s

d/D 0.5 0.6 0.7 0.8 0.9


A0016359

Length of connecting cable To ensure correct measuring results when using the remote version,
observe the maximum permitted cable length Lmax. This length is determined by the conductivity of
the fluid.
If measuring liquids in general: 5 µS/cm

[µS/cm]

200

100
L max

5 [m]
10 100 200 L max
[ft]
0 200 400 600

A0016539

 20 Permitted length of connecting cable for remote version


Area shaded gray = permitted range
Lmax= length of connecting cable in [m] ([ft])
[µS/cm] = fluid conductivity

36 Endress+Hauser
Proline Promag W 400

Installing the wall-mount Wall mounting


housing
17 (0.67) = =

14 (0.55)
5.8 (0.23)

210.5 (8.29)
5.8 (0.23)
149 (5.85)

A0020523

 21 Engineering unit mm (in)

Post mounting

ø 20…70 3x TX 25
(ø 0.79…2.75)

)
~ 4.0
02(
~1

4x SW 8

A0020705

 22 Engineering unit mm (in)

Special mounting Display protection


instructions
To ensure that the optional display protection can be easily opened, maintain the following
minimum head clearance: 350 mm (13.8 in)

Permanent immersion in water


A fully welded remote version with IP68 protection is optionally available for permanent immersion
in water ≤ 3 m (10 ft) or in exceptional cases for use for up to 48 hours at ≤ 10 m (30 ft). The
measuring device meets the requirements of corrosion categories C5-M and Im1/Im2/Im3. The fully
welded design along with the connection compartment sealing system ensure that moisture cannot
enter the measuring device.

Endress+Hauser 37
Proline Promag W 400

≤ 3 (≤ 10)
A0017296

 23 Engineering unit in m(ft)

Replacement of cable gland on connection housing →  29

Buried applications
A remote version with IP68 protection is optionally available for buried applications. The measuring
device satisfies the certified corrosion protection Im1/Im2/Im3 in accordance with EN ISO 12944. It
can be used directly underground without the need for additional protective measures. The device is
mounted in accordance with the usual regional installation regulations (e.g. EN DIN 1610).

A0017298

Environment
Ambient temperature range Transmitter –40 to +60 °C (–40 to +140 °F)

Local display –20 to +60 °C (–4 to +140 °F), the readability of the display may be
impaired at temperatures outside the temperature range.

Sensor • Process connection material, carbon steel:


–10 to +60 °C (+14 to +140 °F)
• Process connection material, stainless steel:
–40 to +60 °C (–40 to +140 °F)
Mount the transmitter separately from the sensor if both the ambient
and fluid temperatures are high.

Liner Do not exceed or fall below the permitted temperature range of the liner .

If operating outdoors:
• Install the measuring device in a shady location.
• Avoid direct sunlight, particularly in warm climatic regions.
• Avoid direct exposure to weather conditions.

38 Endress+Hauser
Proline Promag W 400

• If the compact version of the device is insulated at low temperatures, the insulation must also
include the device neck.
• Protect the display against impact.
• Protect the display from abrasion by sand in desert areas.
A display protector can be ordered from Endress+Hauser: "Accessories" section →  108

Storage temperature The storage temperature corresponds to the operating temperature range of the measuring
transmitter and the appropriate measuring sensors.
• Protect the measuring device against direct sunlight during storage in order to avoid unacceptably
high surface temperatures.
• Select a storage location where moisture cannot collect in the measuring device as fungus or
bacteria infestation can damage the liner.
• If protection caps or protective covers are mounted these should never be removed before
installing the measuring device.

Atmosphere If a plastic transmitter housing is permanently exposed to certain steam and air mixtures, this can
damage the housing.
If you are unsure, please contact your Endress+Hauser Sales Center for clarification.

Degree of protection Transmitter


• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure
Sensor
• As standard: IP66/67, type 4X enclosure
• Optionally available for remote version:
– IP66/67, type 4X enclosure; fully welded, with protective varnish EN ISO 12944 C5-M. Suitable
for use in corrosive atmospheres.
– IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944 C5-M.
Suitable for permanent immersion in water ≤3 m (10 ft) or 48 hours at depths ≤10 m (30 ft).
– IP68, type 6P enclosure; fully welded, with protective varnish as per EN ISO 12944 Im1/Im2/
Im3. Suitable for permanent immersion in saline water ≤3 m (10 ft) or 48 hours at depths ≤
10 m (30 ft) or in buried applications.

Shock resistance Compact version


6 ms 30 g, according to IEC 60068-2-27
Remote version
• Transmitter: 6 ms 30 g, according to IEC 60068-2-27
• Sensor: 6 ms 50 g, according to IEC 60068-2-27

Vibration resistance Compact version


• Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
• Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64
Remote version
• Transmitter
– Vibration sinusoidal, 1 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 1.54 g rms, according to IEC 60068-2-64
• Sensor:
– Vibration sinusoidal, 2 g peak, according to IEC 60068-2-6
– Vibration broad-band random, 2.70 g rms, according to IEC 60068-2-64

Mechanical load • Protect the transmitter housing against mechanical effects, such as shock or impact; the use of the
remote version is sometimes preferable.
• Never use the transmitter housing as a ladder or climbing aid.

Endress+Hauser 39
Proline Promag W 400

Electromagnetic • As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)


compatibility (EMC) • Complies with emission limits for industry as per EN 55011 (Class A)
• Device version with PROFIBUS DP: Complies with emission limits for industry as per EN 50170
Volume 2, IEC 61784
The following applies for PROFIBUS DP: If baud rates > 1.5 MBaud an EMC cable entry must be
used and the cable shield must continue as far as the terminal wherever possible.
For details refer to the Declaration of Conformity.

Process
Medium temperature range • 0 to +80 °C (+32 to +176 °F) for hard rubber, DN 50 to 2000 (2 to 78")
• –20 to +50 °C (–4 to +122 °F) for polyurethane, DN 25 to 1200 (1 to 48")
In custody transfer mode, the permitted fluid temperature is 0 to +50 °C (+32 to +122 °F).

Conductivity ≥ 5 μS/cm for liquids in general


Note that in the case of the remote version, the requisite minimum conductivity also depends
on the cable length →  36.

Pressure-temperature The following pressure-temperature ratings refer to the entire device and not just the process
ratings connection.

Process connection: fixed flange according to EN 1092-1 (DIN 2501)

[psi] [bar]
600 40
PN 40
500 35
30
400
25
PN 25
300 20

200 15
PN 16
10
100 PN 10
5
PN 6
0 0
-40 -20 0 20 40 60 80 100120140160180 [°C]

-40 0 100 200 300 360 [°F]


A0021188-EN

 24 Process connection material: stainless steel, 1.4404/1.4571/F316L; carbon steel, A105/FE410WB/


P250GH/S235JRG2/S235JR+N

40 Endress+Hauser
Proline Promag W 400

Process connection: fixed flange according to ASME B16.5

[psi] [bar]
900 60
800
700 50
600 40
500 Class 300
400 30
300 20
200
10 Class 150
100
0 0
-40 -20 0 20 40 60 80 100120140 160180 [°C]

-40 0 100 200 300 360 [°F]


A0021185-EN

 25 Process connection material: stainless steel, F316L similar to 1.4404

[psi] [bar]
900 60
800
700 50 Class 300
600 40
500
400 30
300 20
200 Class 150
10
100
0 0
-40 -20 0 20 40 60 80 100120140 160180 [°C]

-40 0 100 200 300 360 [°F]


A0021182-EN

 26 Process connection material: carbon steel, A105/A515(70)

Process connection: fixed flange according to AWWA C207

[psi] [bar]
160 11
145 10 Class D
130 9
116 8
0 0
-40 -20 0 20 40 60 80 100120140160 [°C]

-40 0 100 200 300 [°F]


A0021409-EN

 27 Process connection material: carbon steel, A105/A181/P265GH/S275JR

Endress+Hauser 41
Proline Promag W 400

Process connection: fixed flange according to AS 2129

[psi] [bar]

300 20

200 15
Table E
10
100
5
0 0
-40 -20 0 20 40 60 80 100120140 160 [°C]

-40 0 100 200 300 [°F]


A0021189-EN

 28 Process connection material: carbon steel, A105/FE410WB/P235GH/P265GH/S235JRG2

Process connection: fixed flange according to AS 4087

[psi] [bar]

300 20
PN 16
200 15
10
100
5
0 0
-40 -20 0 20 40 60 80 100120140 160 [°C]

-40 0 100 200 300 [°F]


A0023077-EN

 29 Process connection material: carbon steel, A105/P265GH/S275JR

Process connection: fixed flange according to JIS B2220

[psi] [bar]
30
400

300 20K
20

200
10K
10
100

0 0
-40 -20 0 20 40 60 80 100120140 160180 [°C]

-40 0 100 200 300 360 [°F]


A0021183-EN

 30 Process connection material: stainless steel, F316L similar to 1.4404; carbon steel, A105/A350LF2

Pressure tightness Liner: hard rubber


Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:

[mm] [in] +25 °C (+77 °F) +50 °C (+122 °F) +80 °C (+176 °F)

50…2000 2…78 0 (0) 0 (0) 0 (0)

42 Endress+Hauser
Proline Promag W 400

Liner: polyurethane
Nominal diameter Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:

[mm] [in] +25 °C (+77 °F) +50 °C (+122 °F)

25…1200 1…48 0 (0) 0 (0)

Flow limit The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The
optimum velocity of flow is between 2 to 3 m/s (6.56 to 9.84 ft/s). Also match the velocity of flow
(v) to the physical properties of the fluid:
• v < 2 m/s (6.56 ft/s): for abrasive fluids (e.g. potter's clay, lime milk, ore slurry)
• v > 2 m/s (6.56 ft/s): for fluids producing buildup (e.g. wastewater sludges)
A necessary increase in the flow velocity can be achieved by reducing the sensor nominal
diameter.
For an overview of the measuring range full scale values, see the "Measuring range" section
→ 7
For custody transfer, the applicable approval determines the permitted measuring range.

Pressure loss • No pressure loss occurs if the sensor is installed in a pipe with the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545 →  35

System pressure

A0015594

Never install the sensor on the pump suction side in order to avoid the risk of low pressure, and thus
damage to the liner.
Furthermore, install pulse dampers if reciprocating, diaphragm or peristaltic pumps are used.

• For information on the liner's resistance to partial vacuum →  42


• For information on the shock resistance of the measuring system →  39
• For information on the vibration resistance of the measuring system →  39

Vibrations In the event of very strong vibrations, the pipe and sensor must be supported and fixed.
It is also advisable to mount the sensor and transmitter separately.
• For information on the shock resistance of the measuring system →  39
• For information on the vibration resistance of the measuring system →  39

L
A0016266

 31 Measures to avoid device vibrations (L > 10 m (33 ft))

Endress+Hauser 43
Proline Promag W 400

Mechanical construction
Dimensions in SI units Compact version

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated"

A D
B C

E
G
F
J
H K
A0020352

DN 1) A B C D E F G H J K 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 193 103 90 167 222 84 306 120 94 200

32 193 103 90 167 222 84 306 120 94 200

40 193 103 90 167 222 84 306 120 94 200

50 193 103 90 167 222 84 306 120 94 200

65 193 103 90 167 247 109 356 180 94 200

80 193 103 90 167 247 109 356 180 94 200

100 193 103 90 167 247 109 356 180 94 250

125 193 103 90 167 287 150 437 260 140 250

150 193 103 90 167 287 150 437 260 140 300

200 193 103 90 167 312 180 492 324 156 350

250 193 103 90 167 337 205 542 400 166 450

300 193 103 90 167 362 230 592 460 166 500

1) EN (DIN), AS, JIS; For flanges according to AS, only nominal diameters DN 80, 100 and 150 to 300 are
available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

44 Endress+Hauser
Proline Promag W 400

A D
B C

E
G
F
J

H K
A0017154

DN 1) A B C D E F G H J K 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 193 103 90 167 432 282 714 564 276 550

375 193 103 90 167 458 308 766 616 276 600

400 193 103 90 167 458 308 766 616 276 600

450 193 103 90 167 483 333 816 666 292 650

500 193 103 90 167 508 359 867 717 292 650

600 193 103 90 167 560 410 970 821 402 780

700 193 103 90 167 662 512 1174 1024 589 910

750 193 103 90 167 662 512 1174 1024 626 975

800 193 103 90 167 683 534 1217 1067 647 1040

900 193 103 90 167 760 610 1370 1220 785 1170

1000 193 103 90 167 836 686 1522 1372 862 1300

1050 193 103 90 167 862 712 1574 1424 912 1365

1200 193 103 90 167 961 811 1772 1622 992 1560

1350 193 103 90 167 1062 912 1974 1824 1252 1755

1400 193 103 90 167 1137 987 2124 1974 1252 1820

1500 193 103 90 167 1161 1011 2172 2022 1392 1950

1600 193 103 90 167 1206 1056 2262 2112 1482 2080

1650 193 103 90 167 1243 1093 2336 2186 1482 2145

1800 193 103 90 167 1338 1188 2526 2376 1632 2340

2000 193 103 90 167 1388 1238 2626 2476 1732 2600

1) EN (DIN), AS; For flanges according to AS, only nominal diameters DN 350, 400, 500 and 600 are
available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Endress+Hauser 45
Proline Promag W 400

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated";
order code for "Design", option A "Insertion length short"

A D
B C

E
F
H

G J

A0017153

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 193 103 90 167 386 290 550

375 193 103 90 167 412 290 600

400 193 103 90 167 412 290 600

450 193 103 90 167 440 290 600

500 193 103 90 167 465 290 600

600 193 103 90 167 506 290 600

700 193 103 90 167 571 424 700

750 193 103 90 167 608 454 750

800 193 103 90 167 627 500 800

900 193 103 90 167 677 580 900

1000 193 103 90 167 727 660 1000

1050 193 103 90 167 763 755 1050

1200 193 103 90 167 841 828 1200

1350 193 103 90 167 953 1008 1350

1400 193 103 90 167 953 1008 1400

1500 193 103 90 167 1053 1147 1500

1600 193 103 90 167 1053 1147 1600

1650 193 103 90 167 1104 1284 1650

1800 193 103 90 167 1161 1379 1800

2000 193 103 90 167 1272 1569 2000

46 Endress+Hauser
Proline Promag W 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 631 638 702 653 648 490 505 520 533 525

375 – – – – 687 – – – – 550

400 682 694 760 710 702 540 565 580 597 580

450 737 747 823 757 760 595 615 640 635 640

500 787 800 926 814 817 645 670 715 699 705

600 883 896 1026 912 918 755 780 840 813 825

700 1001 1018 1145 1034 1026 860 895 910 927 910

750 – – – 1100 1106 – – – 984 995

800 1115 1135 1240 1157 1157 975 1015 1025 1060 1060

900 1215 1235 1240 1261 1265 1075 1115 1125 1168 1175

1000 1315 1342 1355 1372 1355 1175 1230 1225 1289 1255

1050 – – – 1436 – – – – 1346 –

1200 1544 1569 1584 1597 1586 1405 1455 1255 1511 1490

1350 – – – 1795 – – – – 1683 –

1400 1768 1791 1796 – – 1630 1675 1685 – –

1500 – – – 1980 – – – – 1854 –

1600 1968 2011 2019 – – 1830 1915 1930 – –

1650 – – – 2120 – – – – 2032 –

1800 2183 2218 2226 2259 – 2045 2115 2130 2197 –

2000 2404 2434 2444 2453 – 2265 2325 2345 2362 –

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"

A D
B C

22.5°
E
G
F

J
H K
A0020353

Endress+Hauser 47
Proline Promag W 400

DN 1) A B C D E F G H J K 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 199 119 80 167 267 84 351 120 94 200

32 199 119 80 167 267 84 351 120 94 200

40 199 119 80 167 267 84 351 120 94 200

50 199 119 80 167 267 84 351 120 94 200

65 199 119 80 167 292 109 401 180 94 200

80 199 119 80 167 292 109 401 180 94 200

100 199 119 80 167 292 109 401 180 94 250

125 199 119 80 167 332 150 482 260 140 250

150 199 119 80 167 332 150 482 260 140 300

200 199 119 80 167 357 180 537 324 156 350

250 199 119 80 167 382 205 587 400 166 450

300 199 119 80 167 407 230 637 460 166 500

1) EN (DIN), AS, JIS; For flanges according to AS, only nominal diameters DN 80, 100 and 150 to 300 are
available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

A D
B C

22.5°

E
G
F

H K
A0020396

DN 1) A B C D E F G H J K 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 199 119 80 167 477 282 759 564 276 550

375 199 119 80 167 503 308 811 616 276 600

400 199 119 80 167 503 308 811 616 276 600

450 199 119 80 167 528 333 861 666 292 650

500 199 119 80 167 553 359 912 717 292 650

600 199 119 80 167 605 410 1015 821 402 780

700 199 119 80 167 707 512 1219 1024 589 910

750 199 119 80 167 707 512 1219 1024 626 975

48 Endress+Hauser
Proline Promag W 400

DN 1) A B C D E F G H J K 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

800 199 119 80 167 728 534 1262 1067 647 1040

900 199 119 80 167 805 610 1415 1220 785 1170

1000 199 119 80 167 881 686 1567 1372 862 1300

1050 199 119 80 167 907 712 1619 1424 912 1365

1200 199 119 80 167 1006 811 1817 1622 992 1560

1350 199 119 80 167 1107 912 2019 1824 1252 1755

1400 199 119 80 167 1182 987 2169 1974 1252 1820

1500 199 119 80 167 1206 1011 2217 2022 1392 1950

1600 199 119 80 167 1251 1056 2307 2112 1482 2080

1650 199 119 80 167 1288 1093 2381 2186 1482 2145

1800 199 119 80 167 1383 1188 2571 2376 1632 2340

2000 199 119 80 167 1433 1238 2671 2476 1732 2600

1) EN (DIN), AS; For flanges according to AS, only nominal diameters DN 350, 400, 500 and 600 are
available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"; order code for "Design", option A "Insertion length short"

A D
B C

22.5°

E
F

G J

A0020393

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 199 119 80 167 431 290 550

375 199 119 80 167 457 290 600

400 199 119 80 167 457 290 600

450 199 119 80 167 485 290 600

500 199 119 80 167 510 290 600

600 199 119 80 167 551 290 600

Endress+Hauser 49
Proline Promag W 400

DN A B C D E H J

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

700 199 119 80 167 616 424 700

750 199 119 80 167 653 454 750

800 199 119 80 167 672 500 800

900 199 119 80 167 722 580 900

1000 199 119 80 167 772 660 1000

1050 199 119 80 167 808 755 1050

1200 199 119 80 167 886 828 1200

1350 199 119 80 167 998 1008 1350

1400 199 119 80 167 953 1008 1400

1500 199 119 80 167 1098 1147 1500

1600 199 119 80 167 1098 1147 1600

1650 199 119 80 167 1149 1284 1650

1800 199 119 80 167 1206 1379 1800

2000 199 119 80 167 1317 1569 2000

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 676 683 618 698 693 490 505 520 533 525

375 – – – – 732 – – – – 550

400 727 739 672 755 747 540 565 580 597 580

450 782 792 732 802 805 595 615 640 635 640

500 832 845 795 859 862 645 670 715 699 705

600 928 941 898 957 963 755 780 840 813 825

700 1046 1063 1008 1079 1071 860 895 910 927 910

750 – – – 1145 1151 – – – 984 995

800 1160 1180 1112 1202 1202 975 1015 1025 1060 1060

900 1260 1280 1212 1306 1310 1075 1115 1125 1168 1175

1000 1360 1387 1327 1417 1400 1175 1230 1225 1289 1255

1050 – – – 1481 – – – – 1346 –

1200 1589 1614 1556 1642 1631 1405 1455 1255 1511 1490

1350 – – – 1840 – – – – 1683 –

1400 1813 1836 1768 – – 1630 1675 1685 – –

1500 – – – 2025 – – – – 1854 –

1600 2013 2056 1991 – – 1830 1915 1930 – –

1650 – – – 2165 – – – – 2032 –

1800 2228 2263 2198 2304 – 2045 2115 2130 2197 –

2000 2449 2479 2416 2498 – 2265 2325 2345 2362 –

50 Endress+Hauser
Proline Promag W 400

Order code for "Sensor option", option CA in combination with order code for "Calibration flow", options
A/B/D/E/F/G/H/K/M/N
• Order code for "Calibration flow", options A/B/D/E/F/G/H/K/M/N available for order in
conjunction with order code for "Housing", option M "Compact, polycarbonate"
• Order code for "Calibration flow", options H/K also available for order in conjunction with
order code for "Housing", option A "Compact, aluminum, coated"

A D
B C

G
H
E F

A0021328

DN A B C D F G

[mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 193 103 90 167 200 188

32 193 103 90 167 200 188

40 193 103 90 167 200 188

50 193 103 90 167 200 188

65 193 103 90 167 200 200

80 193 103 90 167 200 205

100 193 103 90 167 250 218

125 193 103 90 167 250 231

150 193 103 90 167 300 252

200 193 103 90 167 350 278

250 193 103 90 167 450 311

300 193 103 90 167 500 336

Dimension E

EN (DIN) ASME AS JIS


DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K
150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 140 140 140 140 – 140 140

32 – – – 140 – – – – 140 140

40 – – – 150 140 155 – – 140 140

50 – – – 165 153 165 150 150 155 155

65 – 185 – 185 – – – – 175 175

80 – 200 – 200 191 210 185 185 185 200

100 – 220 – 325 229 254 215 215 210 225

Endress+Hauser 51
Proline Promag W 400

Dimension E

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

125 – 250 – 270 – – – – 250 270

150 – 285 – 300 280 318 280 280 280 305

200 340 340 360 – 343 – 335 335 330 350

250 395 405 425 – 407 – 405 405 400 430

300 445 460 485 – 483 – 455 455 445 480

Dimension H

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 258 258 258 258 – 258 258

32 – – – 258 – – – – 258 258

40 – – – 262 258 265 – – 258 258

50 – – – 270 263 270 262 262 265 265

65 – 293 – 293 – – – – 288 288

80 – 305 – 305 300 309 298 298 298 305

100 – 328 – 380 331 344 325 325 323 330

125 – 355 – 365 – – – – 355 365

150 – 394 – 402 391 410 393 393 393 404

200 448 448 458 – 448 – 445 445 443 452

250 508 513 523 – 514 – 513 513 511 526

300 558 566 578 – 578 – 563 563 558 576

Order code for "Sensor option", option CA in combination with order code for "Calibration flow", options
A/B/D/E/F/G/H/K/M/N
• Order code for "Calibration flow", options A/B/D/E/F/G/H/K/M/N available for order in
conjunction with order code for "Housing", option Q "Compact, polycarbonate, inclined"
• Order code for "Calibration flow", options H/K also available for order in conjunction with
order code for "Housing", option R "Compact, aluminum, coated, inclined"

52 Endress+Hauser
Proline Promag W 400

A D
B C

22.5°

G
H
E F

A0021329

DN A B C D F G

[mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 199 119 80 167 200 232

32 199 119 80 167 200 232

40 199 119 80 167 200 232

50 199 119 80 167 200 232

65 199 119 80 167 200 244

80 199 119 80 167 200 249

100 199 119 80 167 250 262

125 199 119 80 167 250 275

150 199 119 80 167 300 296

200 199 119 80 167 350 322

250 199 119 80 167 450 355

300 199 119 80 167 500 380

Dimension E

EN (DIN) ASME AS JIS


DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K
150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 140 140 140 140 – 140 140

32 – – – 140 – – – – 140 140

40 – – – 150 140 155 – – 140 140

50 – – – 165 153 165 150 150 155 155

65 – 185 – 185 – – – – 175 175

80 – 200 – 200 191 210 185 185 185 200

100 – 220 – 325 229 254 215 215 210 225

125 – 250 – 270 – – – – 250 270

150 – 285 – 300 280 318 280 280 280 305

200 340 340 360 – 343 – 335 335 330 350

Endress+Hauser 53
Proline Promag W 400

Dimension E

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

250 395 405 425 – 407 – 405 405 400 430

300 445 460 485 – 483 – 455 455 445 480

Dimension H

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 302 302 302 302 – 302 302

32 – – – 302 – – – – 302 302

40 – – – 307 302 310 – – 302 302

50 – – – 315 309 315 307 307 310 310

65 – 337 – 337 – – – – 332 332

80 – 349 – 349 345 354 342 342 342 349

100 – 372 – 425 377 389 370 370 367 375

125 – 400 – 410 – – – – 400 410

150 – 439 – 446 436 455 436 436 436 449

200 492 492 502 – 494 – 490 490 487 497

250 553 558 568 – 559 – 558 558 555 570

300 603 610 623 – 622 – 608 608 603 620

54 Endress+Hauser
Proline Promag W 400

Transmitter remote version

Order code for "Housing", option N "Remote, polycarbonate" or option P "Remote, aluminum coated"

B
C
E
D
A F

A0020522

A B C D E F G H
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

167 24 187 21 232 80 50 240

Sensor remote version

A
B
D
C

F
E G

A0017282

Endress+Hauser 55
Proline Promag W 400

DN 1) A B C D E F G 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 136 207 84 291 120 94 200

32 136 207 84 291 120 94 200

40 136 207 84 291 120 94 200

50 136 207 84 291 120 94 200

65 136 232 109 341 180 94 200

80 136 232 109 341 180 94 200

100 136 232 109 341 180 94 250

125 136 272 150 422 260 140 250

150 136 272 150 422 260 140 300

200 136 297 180 477 324 156 350

250 136 322 205 527 400 156 450

300 136 347 230 577 460 166 500

1) EN (DIN), AS, JIS; For flanges according to AS, only nominal diameters DN 80, 100 and 150 to 300 are
available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

B
D
C

F
E G

A0017283

DN 1) A B C D E F G 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 136 407 282 689 564 276 550

375 136 433 308 741 616 276 600

400 136 433 308 741 616 276 600

450 136 458 333 791 666 292 650

500 136 483 359 842 717 292 650

600 136 535 411 946 821 402 780

700 136 637 512 1149 1024 589 910

750 136 637 512 1149 1024 626 975

800 136 658 534 1192 1067 647 1040

56 Endress+Hauser
Proline Promag W 400

DN 1) A B C D E F G 2)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

900 136 735 610 1345 1220 785 1170

1000 136 811 686 1497 1372 862 1300

1050 136 837 712 1549 1424 912 1365

1200 136 936 811 1747 1622 992 1560

1350 136 1037 912 1949 1824 1252 1755

1400 136 1112 987 2099 1974 1252 1820

1500 136 1136 1011 2147 2022 1392 1950

1600 136 1181 1056 2237 2112 1482 2080

1650 136 1218 1093 2311 2186 1482 2145

1800 136 1313 1188 2501 2376 1632 2340

2000 136 1363 1238 2601 2476 1732 2600

1) EN (DIN), AS; For flanges according to AS, only nominal diameters DN 350, 400, 500 and 600 are available.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Design", option A "Insertion length short"

B
E C

D F
A0017284

DN A B E F

[mm] [mm] [mm] [mm] [mm]

350 136 358 290 550

375 136 384 290 600

400 136 384 290 600

450 136 412 290 600

500 136 437 290 600

600 136 478 290 600

700 136 543 424 700

750 136 579 454 750

800 136 599 500 800

900 136 649 580 900

Endress+Hauser 57
Proline Promag W 400

DN A B E F

[mm] [mm] [mm] [mm] [mm]

1000 136 699 660 1000

1050 136 735 755 1050

1200 136 813 828 1200

1350 136 925 1008 1350

1400 136 925 1008 1400

1500 136 1025 1147 1500

1600 136 1025 1147 1600

1650 136 1076 1284 1650

1800 136 1133 1379 1800

2000 136 1244 1569 2000

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 603 610 616 625 620 490 505 520 533 525

375 – – – – 659 – – – – 550

400 654 666 672 682 674 540 565 580 597 580

450 709 719 729 729 732 595 615 640 635 640

500 759 772 791 786 789 645 670 715 699 705

600 855 868 903 884 890 755 780 840 813 825

700 973 990 1009 1006 998 860 895 910 927 910

750 – – – 1072 1078 – – – 984 995

800 1087 1107 1123 1129 1129 975 1015 1025 1060 1060

900 1187 1207 1223 1233 1237 1075 1115 1125 1168 1175

1000 1287 1314 1338 1344 1327 1175 1230 1225 1289 1255

1050 – – – 1408 – – – – 1346 –

1200 1516 1541 1567 1569 1558 1405 1455 1255 1511 1490

1350 – – – 1767 – – – – 1683 –

1400 1740 1763 1779 – – 1630 1675 1685 – –

1500 – – – 1952 – – – – 1854 –

1600 1940 1983 2002 – – 1830 1915 1930 – –

1650 – – – 2092 – – – – 2032 –

1800 2155 2190 2209 2231 – 2045 2115 2130 2197 –

2000 2376 2406 2427 2425 – 2265 2325 2345 2362 –

Order code for "Sensor option", option CA…CE "Corrosion protection"

Option Description

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

CB IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CC IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

58 Endress+Hauser
Proline Promag W 400

Option Description

CD Buried IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 Im2/Im3

CE Buried IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 Im2/Im3

B
D
C L

A0020399

DN A B L

[mm] [mm] [mm] [mm]

25 112 189 200

32 112 189 200

40 112 189 200

50 112 189 200

65 112 202 200

80 112 207 200

100 112 219 250

125 112 232 250

150 112 254 300

200 112 279 350

250 112 313 450

300 112 338 500

Dimension C

EN (DIN) ASME AS JIS


DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K
150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 140 110 140 140 – 140 140

32 – – – 140 – – – – 140 140

40 – – – 150 125 155 – – 140 140

50 – – – 165 150 165 150 150 155 155

65 – 185 – 185 – – – – 175 175

80 – 200 – 200 190 209.6 185 185 185 200

100 – 220 – 325 230 254 215 215 210 225

125 – 250 – 270 – – – – 250 270

150 – 285 – 300 280 317.5 280 280 280 305

Endress+Hauser 59
Proline Promag W 400

Dimension C

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

200 340 340 360 – 345 – 335 335 330 350

250 395 405 425 – 405 – 405 405 400 430

300 445 460 485 – 485 – 455 455 445 480

Dimension D

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

25 – – – 260 260 260 260 – 260 260

32 – – – 260 – – – – 260 260

40 – – – 264 260 267 – – 260 260

50 – – – 272 265 272 264 264 267 267

65 – 295 – 295 – – – – 290 290

80 – 307 – 307 302 311 300 300 300 307

100 – 330 – 382 333 346 327 327 325 332

125 – 357 – 367 – – – – 357 367

150 – 396 – 404 393 412 395 395 395 406

200 450 450 460 – 450 – 447 447 445 454

250 510 515 525 – 516 – 515 515 513 528

300 560 568 580 – 580 – 565 565 560 578

A
B
D
C

F
E G
A0020435

60 Endress+Hauser
Proline Promag W 400

DN A B C D E F G 1)

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 112 395 282 677 564 276 550

375 112 421 308 729 616 276 600

400 112 421 308 729 616 276 600

450 112 446 333 779 666 292 650

500 112 472 359 830 717 292 650

600 112 524 411 934 821 402 780

700 112 625 512 1137 1024 589 910

750 112 625 512 1137 1024 626 975

800 112 647 534 1180 1067 647 1040

900 112 723 610 1333 1220 785 1170

1000 112 799 686 1485 1372 862 1300

1050 112 825 712 1537 1424 912 1365

1200 112 924 811 1735 1622 992 1560

1350 112 1025 912 1937 1824 1252 1755

1400 112 1100 987 2087 1974 1252 1820

1500 112 1124 1011 2135 2022 1392 1950

1600 112 1169 1056 2225 2112 1482 2080

1650 112 1206 1093 2299 2186 1482 2145

1800 112 1301 1188 2489 2376 1632 2340

2000 112 1351 1238 2589 2476 1732 2600

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Design", option A "Insertion length short" and order code for "Sensor option", option
CA…CE "Corrosion protection"

Option Description

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

CB IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CC IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CD Buried IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 Im2/Im3

CE Buried IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 Im2/Im3

Endress+Hauser 61
Proline Promag W 400

B
C
E
D F

A0018158

DN A B E F

[mm] [mm] [mm] [mm] [mm]

350 112 350 290 550

375 112 376 290 600

400 112 376 290 600

450 112 403 290 600

500 112 428 290 600

600 112 478 290 600

700 112 549 424 700

750 112 586 454 750

800 112 605 500 800

900 112 655 580 900

1000 112 705 660 1000

1050 112 741 755 1050

1200 112 819 828 1200

1350 112 931 1008 1350

1400 112 931 1008 1400

1500 112 1031 1147 1500

1600 112 1031 1147 1600

1650 112 1082 1284 1650

1800 112 1139 1379 1800

2000 112 1250 1569 2000

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS


DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

350 595 603 610 – 613 490 505 520 – 525

375 – – – – 651 – – – – 550

62 Endress+Hauser
Proline Promag W 400

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

400 646 659 666 – 666 540 565 580 – 580

450 701 711 723 – 723 595 615 640 – 640

500 751 763 786 – 781 645 670 715 – 705

600 856 868 898 – 891 755 780 840 – 825

700 979 996 1004 1012 1004 860 895 910 927 910

750 – – – 1078 1084 – – – 984 995

800 1093 1113 1118 1135 1135 975 1015 1025 1060 1060

900 1193 1213 1218 1239 1243 1075 1115 1125 1168 1175

1000 1293 1320 1333 1350 1333 1175 1230 1225 1289 1255

1050 – – – 1414 – – – – 1346 –

1200 1522 1547 1562 1575 1564 1405 1455 1255 1511 1490

1350 – – – 1773 – – – – 1683 –

1400 1746 1769 1774 – – 1630 1675 1685 – –

1500 – – – 1958 – – – – 1854 –

1600 1946 1989 1997 – – 1830 1915 1930 – –

1650 – – – 2098 – – – – 2032 –

1800 2161 2196 2204 2237 – 2045 2115 2130 2197 –

2000 2382 2412 2422 2431 – 2265 2325 2345 2362 –

Accessories

Ground disks for flange connections

DN ≤ 300 (12") DN 300…600 (14…24") DN ≥ 700 (28")


! 9 (0.35) ! 6.4 (0.25)
! 6.5 (0.26)

H
H
H

!B A
!B ! !D !A !D
!A !D

t = 2 (0.08) t = 2 (0.08) t = 2 (0.08)


A0015442

 32 Engineering unit mm (in)

DN Pressure rating A B D H

[mm] [mm] [mm] [mm] [mm]


1)
25 26 62 77.5 87.5
1)
32 35 80 87.5 94.5
1)
40 41 82 101 103

Endress+Hauser 63
Proline Promag W 400

DN Pressure rating A B D H

[mm] [mm] [mm] [mm] [mm]


1)
50 52 101 115.5 108
1)
65 68 121 131.5 118
1)
80 80 131 154.5 135
1)
100 104 156 186.5 153
1)
125 130 187 206.5 160
1)
150 158 217 256 184
1)
200 206 267 288 205
1)
250 260 328 359 240
1)
300 312 375 413 273

350 DIN, PN 6 343 433 479 365

350 DIN, PN 10 343 400 479 365

350 ASME, Class 343 400 479 365


150

400 DIN, PN 6 393 470 542 395

400 DIN, PN 10 393 469 542 395

400 ASME, Class 393 469 542 395


150

450 DIN, PN 6 439 525 583 417

450 DIN, PN 10 439 535 583 417

450 ASME, Class 439 535 583 417


150

500 DIN, PN 6 493 575 650 460

500 DIN, PN 10 493 588 650 460

500 ASME, Class 493 588 650 460


150

600 DIN, PN 6 593 676 766 522

600 DIN, PN 10 593 688 766 522

600 ASME, Class 593 688 766 522


150

700 DIN, PN 6 697 – 786 460

700 DIN, PN 10 693 – 813 480

700 AS, PN 16 687 – 807 490

700 AWWA, Class D 693 – 832 494

750 AWWA, Class D 743 – 833 523

800 DIN, PN 6 799 – 893 520

800 DIN, PN 10 795 – 920 540

800 AS, PN 16 789 – 914 550

800 AWWA, Class D 795 – 940 561

900 DIN, PN 6 897 – 993 570

900 DIN, PN 10 893 – 1 020 590

900 AS, PN 16 886 – 1 014 595

900 AWWA, Class D 893 – 1 048 615

1 000 DIN, PN 6 999 – 1 093 620

1 000 DIN, PN 10 995 – 1 127 650

64 Endress+Hauser
Proline Promag W 400

DN Pressure rating A B D H

[mm] [mm] [mm] [mm] [mm]

1 000 AS, PN 16 988 – 1 131 660

1 000 AWWA, Class D 995 – 1 163 675

1 050 AWWA, Class D 1 044 – 1 220 704

1 200 DIN, PN 6 1 203 – 1 310 733

1) Ground disks can be used for all the flange standards/pressure ratings which can be supplied in the
standard version.

Dimensions in US units Compact version

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated"

A D
B C

E
G
F
J
H K
A0020352

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

1½ 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

2 7.60 4.06 3.54 6.57 8.74 3.31 12.1 4.72 3.70 7.87

3 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 7.87

4 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 9.84

6 7.60 4.06 3.54 6.57 11.3 5.91 17.2 10.2 5.51 11.8

8 7.60 4.06 3.54 6.57 12.3 7.09 19.4 12.8 6.14 13.8

10 7.60 4.06 3.54 6.57 13.3 8.07 21.4 15.8 6.14 17.7

12 7.60 4.06 3.54 6.57 14.3 9.06 23.4 18.1 6.54 19.7

1) ASME
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Endress+Hauser 65
Proline Promag W 400

A D
B C

E
G
F
J

H K
A0017154

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 7.60 4.06 3.54 6.57 17.0 11.1 28.1 22.2 10.9 21.7

15 7.60 4.06 3.54 6.57 18.0 12.1 30.1 24.2 10.9 23.6

16 7.60 4.06 3.54 6.57 18.0 12.1 30.1 24.2 10.9 23.6

18 7.60 4.06 3.54 6.57 19.0 13.1 32.1 26.2 11.5 25.6

20 7.60 4.06 3.54 6.57 20.0 14.1 34.1 28.2 11.5 25.6

24 7.60 4.06 3.54 6.57 22.1 16.2 38.3 32.3 15.8 30.7

28 7.60 4.06 3.54 6.57 26.1 20.1 46.2 40.3 23.2 35.8

30 7.60 4.06 3.54 6.57 26.1 20.1 46.2 40.3 24.6 38.4

32 7.60 4.06 3.54 6.57 26.9 21.0 47.9 42.0 25.5 40.9

36 7.60 4.06 3.54 6.57 29.9 24.0 53.9 48.0 30.9 46.0

40 7.60 4.06 3.54 6.57 32.9 27.0 59.9 54.0 33.9 51.2

42 7.60 4.06 3.54 6.57 33.9 28.0 61.9 56.0 35.9 53.7

48 7.60 4.06 3.54 6.57 37.8 31.9 69.7 63.8 39.0 61.4

54 7.60 4.06 3.54 6.57 41.8 35.9 77.7 71.8 42.3 69.1

60 7.60 4.06 3.54 6.57 45.7 39.8 85.5 79.6 54.8 76.8

66 7.60 4.06 3.54 6.57 48.9 43.0 91.9 86.0 58.4 84.4

72 7.60 4.06 3.54 6.57 52.7 46.8 99.5 93.5 64.2 92.1

78 7.60 4.06 3.54 6.57 54.7 48.7 103.4 97.5 68.2 102.3

1) ASME, AWWA; flanges ≤ 24 in only available according to ASME, flanges ≥ 28 in only available according
to AWWA.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

66 Endress+Hauser
Proline Promag W 400

Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, aluminum, coated";
order code for "Design", option A "Insertion length short"

A D
B C

E
F
H

G J

A0017153

DN A B C D E H J

[in] [in] [in] [in] [in] [in] [in] [in]

14 7.60 4.06 3.54 6.57 15.2 11.4 21.6

15 7.60 4.06 3.54 6.57 16.2 11.4 23.6

16 7.60 4.06 3.54 6.57 16.2 11.4 23.6

18 7.60 4.06 3.54 6.57 17.3 11.4 23.6

20 7.60 4.06 3.54 6.57 18.3 11.4 23.6

24 7.60 4.06 3.54 6.57 19.9 11.4 23.6

28 7.60 4.06 3.54 6.57 22.5 16.7 27.6

30 7.60 4.06 3.54 6.57 23.9 17.9 29.5

32 7.60 4.06 3.54 6.57 24.7 19.7 31.5

36 7.60 4.06 3.54 6.57 26.6 22.8 35.4

40 7.60 4.06 3.54 6.57 28.6 26.0 39.4

42 7.60 4.06 3.54 6.57 30.0 29.7 41.3

48 7.60 4.06 3.54 6.57 33.1 32.6 47.2

54 7.60 4.06 3.54 6.57 37.5 39.7 53.1

60 7.60 4.06 3.54 6.57 41.4 45.2 59.0

66 7.60 4.06 3.54 6.57 43.4 50.6 64.9

72 7.60 4.06 3.54 6.57 45.7 54.3 70.8

78 7.60 4.06 3.54 6.57 50.1 61.8 78.7

Endress+Hauser 67
Proline Promag W 400

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 24.8 25.1 27.6 25.7 25.5 19.3 19.9 20.5 21.0 20.7

15 – – – – 27 – – – – 21.7

16 26.8 27.3 30.0 27.0 27.6 21.3 22.2 22.8 23.5 22.8

18 29.0 29.4 32.4 29.8 29.9 23.4 24.2 25.2 25.0 25.2

20 31.0 31.5 36.5 32.0 32.1 25.4 26.4 28.1 27.5 27.8

24 34.7 35.3 40.4 35.9 36.1 29.7 30.7 33.1 32.0 32.5

28 39.4 40.1 45.1 40.7 40.4 33.9 35.2 35.8 36.5 35.8

30 – – – 43.3 43.5 – – – 38.7 39.2

32 43.9 44.7 48.8 45.5 45.5 38.4 40.0 40.4 41.7 41.7

36 47.8 48.6 48.8 49.6 49.8 42.3 43.9 44.3 46.0 46.3

40 51.7 52.8 53.4 54.0 53.3 46.3 48.4 48.2 50.7 49.4

42 – – – 56.5 – – – – 53.0 –

48 60.8 61.7 62.4 62.9 62.4 55.3 57.3 49.4 59.5 58.7

54 – – – 70.6 – – – – 66.3 –

60 – – – 77.9 – – – – 73.0 –

66 – – – 83.4 – – – – 80.0 –

72 85.9 87.3 87.6 88.9 – 80.5 83.3 83.9 86.5 –

78 94.6 95.8 96.2 96.6 – 89.2 91.5 92.3 93.0 –

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"

A D
B C

22.5°
E
G
F

J
H K
A0020353

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

1½ 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

2 7.83 4.69 3.15 6.57 10.5 3.31 13.8 4.72 3.70 7.87

68 Endress+Hauser
Proline Promag W 400

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

3 7.83 4.69 3.15 6.57 11.5 4.29 15.8 7.09 3.70 7.87

4 7.83 4.69 3.15 6.57 11.5 4.29 15.8 7.09 3.70 9.84

6 7.83 4.69 3.15 6.57 13.1 5.91 19.0 10.2 5.51 11.8

8 7.83 4.69 3.15 6.57 14.0 7.09 21.1 12.8 6.14 13.8

10 7.83 4.69 3.15 6.57 15.0 8.07 23.1 15.8 6.14 17.7

12 7.83 4.69 3.15 6.57 16.0 9.06 25.1 18.1 6.54 19.7

1) ASME
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

A D
B C

22.5°

E
G
F
J

H K
A0020396

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 7.83 4.69 3.15 6.57 18.8 11.1 29.9 22.2 10.9 21.7

15 7.83 4.69 3.15 6.57 19.8 12.1 31.9 24.2 10.9 23.6

16 7.83 4.69 3.15 6.57 19.8 12.1 31.9 24.2 10.9 23.6

18 7.83 4.69 3.15 6.57 20.8 13.1 33.9 26.2 11.5 25.6

20 7.83 4.69 3.15 6.57 21.8 14.1 35.9 28.2 11.5 25.6

24 7.83 4.69 3.15 6.57 23.8 16.2 40.0 32.3 15.8 30.7

28 7.83 4.69 3.15 6.57 27.8 20.2 48.0 40.3 23.2 35.8

30 7.83 4.69 3.15 6.57 27.8 20.2 48.0 40.3 24.6 38.4

32 7.83 4.69 3.15 6.57 28.7 21.0 49.7 42.0 25.5 40.9

36 7.83 4.69 3.15 6.57 32.7 24.0 55.7 48.0 30.9 46.0

40 7.83 4.69 3.15 6.57 34.7 27.0 61.7 54.0 33.9 51.2

42 7.83 4.69 3.15 6.57 35.7 28.0 63.7 56.0 35.9 53.7

48 7.83 4.69 3.15 6.57 39.6 31.9 71.5 63.8 39.0 61.4

54 7.83 4.69 3.15 6.57 43.6 35.9 79.5 71.8 42.3 69.1

Endress+Hauser 69
Proline Promag W 400

DN 1) A B C D E F G H J K 2)

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

60 7.83 4.69 3.15 6.57 47.5 39.8 87.3 79.6 54.8 76.8

66 7.83 4.69 3.15 6.57 50.7 43.0 93.7 86.0 58.4 84.4

72 7.83 4.69 3.15 6.57 54.4 46.8 101.2 93.5 64.2 92.1

78 7.83 4.69 3.15 6.57 56.4 48.8 105.2 97.5 68.2 102.3

1) ASME, AWWA; flanges ≤ 24 in only available according to ASME, flanges ≥ 28 in only available according
to AWWA.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, aluminum,
coated, inclined"; order code for "Design", option A "Insertion length short"

A D
B C

22.5°

E
F
H

G J

A0020393

DN A B C D E H J

[in] [in] [in] [in] [in] [in] [in] [in]

14 7.83 4.69 3.15 6.57 17.0 11.4 21.6

15 7.83 4.69 3.15 6.57 18.0 11.4 23.6

16 7.83 4.69 3.15 6.57 18.0 11.4 23.6

18 7.83 4.69 3.15 6.57 19.1 11.4 23.6

20 7.83 4.69 3.15 6.57 20.1 11.4 23.6

24 7.83 4.69 3.15 6.57 21.7 11.4 23.6

28 7.83 4.69 3.15 6.57 24.3 16.7 27.6

30 7.83 4.69 3.15 6.57 25.7 17.9 29.5

32 7.83 4.69 3.15 6.57 26.5 19.7 31.5

36 7.83 4.69 3.15 6.57 28.4 22.8 35.4

40 7.83 4.69 3.15 6.57 30.4 26.0 39.4

42 7.83 4.69 3.15 6.57 31.8 29.7 41.3

48 7.83 4.69 3.15 6.57 34.9 32.6 47.2

54 7.83 4.69 3.15 6.57 39.3 39.7 53.1

70 Endress+Hauser
Proline Promag W 400

DN A B C D E H J

[in] [in] [in] [in] [in] [in] [in] [in]

60 7.83 4.69 3.15 6.57 43.2 45.2 59.0

66 7.83 4.69 3.15 6.57 45.2 50.6 64.9

72 7.83 4.69 3.15 6.57 47.5 54.3 70.8

78 7.83 4.69 3.15 6.57 51.9 61.8 78.7

Dimension F Dimension G

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 26.6 26.9 24.3 27.5 27.3 19.3 19.9 20.5 21.0 20.7

15 – – – – 28.8 – – – – 21.7

16 28.6 29.1 26.5 28.8 29.4 21.3 22.2 22.8 23.5 22.8

18 30.8 31.2 28.8 31.6 31.7 23.4 24.2 25.2 25.0 25.2

20 32.8 33.3 31.3 33.8 33.9 25.4 26.4 28.1 27.5 27.8

24 36.5 37.1 35.4 37.7 37.9 29.7 30.7 33.1 32.0 32.5

28 41.2 41.9 39.7 42.5 42.2 33.9 35.2 35.8 36.5 35.8

30 – – – 45.1 45.3 – – – 38.7 39.2

32 45.7 46.5 43.8 47.3 47.3 38.4 40.0 40.4 41.7 41.7

36 49.6 50.4 47.7 51.4 49.8 42.3 43.9 44.3 46.0 46.3

40 53.5 54.6 52.2 55.8 55.1 46.3 48.4 48.2 50.7 49.4

42 – – – 58.3 – – – – 53.0 –

48 62.6 63.5 61.3 64.7 64.2 55.3 57.3 49.4 59.5 58.7

54 – – – 72.4 – – – – 66.3 –

60 – – – 79.7 – – – – 73.0 –

66 – – – 85.2 – – – – 80.0 –

72 87.7 89.1 86.5 90.7 – 80.5 83.3 83.9 86.5 –

78 96.4 97.6 95.1 98.4 – 89.2 91.5 92.3 93.0 –

Order code for "Sensor option", option CA in combination with order code for "Calibration flow", options
A/B/D/E/F/G/H/K/M/N
• Order code for "Calibration flow", options A/B/D/E/F/G/H/K/M/N available for order in
conjunction with order code for "Housing", option M "Compact, polycarbonate"
• Order code for "Calibration flow", options H/K also available for order in conjunction with
order code for "Housing", option A "Compact, aluminum, coated"

Endress+Hauser 71
Proline Promag W 400

A D
B C

G
H
E F

A0021328

DN A B C D F G

[in] [in] [in] [in] [in] [in] [in]

1 7.60 4.06 3.54 6.57 7.87 7.40

2 7.60 4.06 3.54 6.57 7.87 7.40

3 7.60 4.06 3.54 6.57 7.87 8.07

4 7.60 4.06 3.54 6.57 9.84 8.58

6 7.60 4.06 3.54 6.57 11.8 9.92

8 7.60 4.06 3.54 6.57 13.8 10.9

10 7.60 4.06 3.54 6.57 17.7 12.2

12 7.60 4.06 3.54 6.57 19.7 13.2

Dimension E

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 5.51 5.51 5.51 5.51 – 5.51 5.51

2 – – – 6.50 6.02 6.50 5.91 5.91 6.10 6.10

3 – 7.87 – 7.87 7.52 8.27 7.28 7.28 7.28 7.87

4 – 8.66 – 12.8 9.02 10.0 8.46 8.46 8.27 8.86

6 – 11.2 – 11.8 11.0 12.5 11.0 11.0 11.0 12.0

8 13.4 13.4 14.2 – 13.5 – 13.2 13.2 13.0 13.8

10 15.6 15.9 16.7 – 16.0 – 15.9 15.9 15.8 16.9

12 17.5 18.1 19.1 – 19.0 – 17.9 17.9 17.5 18.9

Dimension H

EN (DIN) ASME AS JIS


DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K
150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 10.2 10.2 10.2 10.2 – 10.2 10.2

2 – – – 10.6 10.4 10.6 10.3 10.3 10.4 10.4

72 Endress+Hauser
Proline Promag W 400

Dimension H

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

3 – 12 – 12 11.8 12.2 11.7 11.7 11.7 12

4 – 12.9 – 15 13 13.5 12.8 12.8 12.7 13

6 – 15.5 – 15.8 15.4 16.1 15.5 15.5 15.5 15.9

8 17.6 17.6 18 – 17.6 – 17.5 17.5 17.4 17.8

10 20 20.2 20.6 – 20.2 – 20.2 20.2 20.1 20.7

12 22 22.3 22.8 – 22.8 – 22.2 22.2 22 22.7

Order code for "Sensor option", option CA in combination with order code for "Calibration flow", options
A/B/D/E/F/G/H/K/M/N
• Order code for "Calibration flow", options A/B/D/E/F/G/H/K/M/N available for order in
conjunction with order code for "Housing", option Q "Compact, polycarbonate, inclined"
• Order code for "Calibration flow", options H/K also available for order in conjunction with
order code for "Housing", option R "Compact, aluminum, coated, inclined"

A D
B C

22.5°

G
H

E F

A0021329

DN A B C D F G

[in] [in] [in] [in] [in] [in] [in]

1 7.83 4.69 3.15 6.57 7.87 9.13

2 7.83 4.69 3.15 6.57 7.87 9.13

3 7.83 4.69 3.15 6.57 7.87 9.80

4 7.83 4.69 3.15 6.57 9.84 10.3

6 7.83 4.69 3.15 6.57 11.8 11.7

8 7.83 4.69 3.15 6.57 13.8 12.7

10 7.83 4.69 3.15 6.57 17.7 14.0

12 7.83 4.69 3.15 6.57 19.7 15.0

Endress+Hauser 73
Proline Promag W 400

Dimension E

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 5.51 5.51 5.51 5.51 – 5.51 5.51

2 – – – 6.50 6.02 6.50 5.91 5.91 6.10 6.10

3 – 7.87 – 7.87 7.52 8.27 7.28 7.28 7.28 7.87

4 – 8.66 – 12.8 9.02 10.0 8.46 8.46 8.27 8.86

6 – 11.2 – 11.8 11.0 12.5 11.0 11.0 11.0 12.0

8 13.4 13.4 14.2 – 13.5 – 13.2 13.2 13.0 13.8

10 15.6 15.9 16.7 – 16.0 – 15.9 15.9 15.7 16.9

12 17.5 18.1 19.1 – 19.0 – 17.9 17.9 17.5 18.9

Dimension H

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 11.9 11.9 11.9 11.9 – 11.9 11.9

2 – – – 12.4 12.2 12.4 12.1 12.1 12.2 12.2

3 – 13.7 – 13.7 13.6 13.9 13.5 13.5 13.5 13.7

4 – 14.6 – 16.7 14.8 15.3 14.6 14.6 14.4 14.8

6 – 17.3 – 17.6 17.2 17.9 17.2 17.2 17.2 17.7

8 19.4 19.4 19.8 – 19.4 – 19.3 19.3 19.2 19.6

10 21.8 22.0 22.4 – 22.0 – 22.0 22.0 21.9 22.4

12 23.7 24.0 24.5 – 24.5 – 23.9 23.9 23.7 24.4

74 Endress+Hauser
Proline Promag W 400

Transmitter remote version

Order code for "Housing", option N "Remote, polycarbonate" or option P "Remote, aluminum coated"

B
C
E
D
A F

A0020522

A B C D E F G H
[in] [in] [in] [in] [in] [in] [in] [in]

6.57 0.94 7.36 0.83 9.13 3.15 1.97 9.5

Sensor remote version

A
B
D
C

F
E G

A0017282

Endress+Hauser 75
Proline Promag W 400

DN 1) A B C D E F G 2)

[in] [in] [in] [in] [in] [in] [in] [in]

1 5.35 8.15 3.31 11.5 4.72 3.70 7.87

1½ 5.35 8.15 3.31 11.5 4.72 3.70 7.87

2 5.35 8.15 3.31 11.5 4.72 3.70 7.87

3 5.35 9.13 4.29 13.4 7.09 3.70 7.87

4 5.35 9.13 4.29 13.4 7.09 3.70 9.84

6 5.35 10.7 5.91 16.6 10.2 5.51 11.8

8 5.35 11.7 7.09 18.8 12.8 6.14 13.8

10 5.35 12.7 8.07 20.8 15.8 6.14 17.7

12 5.35 13.7 9.06 22.8 18.1 6.54 19.7

1) ASME
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

B
D
C
F
E G

A0017283

DN 1) A B C D E F G 2)

[in] [in] [in] [in] [in] [in] [in] [in]

14 5.35 16.0 11.1 29.3 22.2 10.9 21.7

15 5.35 17.0 12.1 31.3 24.2 10.9 23.6

16 5.35 17.0 12.1 31.3 24.2 10.9 23.6

18 5.35 18.0 13.1 33.3 26.2 11.5 25.6

20 5.35 19.0 14.1 35.3 28.2 11.5 25.6

24 5.35 21.1 16.2 39.4 32.3 15.8 30.7

28 5.35 25.1 20.1 45.2 40.3 23.2 35.8

30 5.35 25.1 20.1 45.2 40.3 24.6 38.4

32 5.35 25.9 21.0 46.9 42.0 25.5 40.9

36 5.35 28.9 24.0 52.9 48.0 30.9 46.0

40 5.35 31.9 27.0 58.9 54.0 33.9 51.2

42 5.35 32.9 28.0 60.9 56.0 35.9 53.7

48 5.35 36.8 31.9 68.7 63.8 39.0 61.4

76 Endress+Hauser
Proline Promag W 400

DN 1) A B C D E F G 2)

[in] [in] [in] [in] [in] [in] [in] [in]

54 5.35 40.8 35.9 76.7 71.8 42.3 69.1

60 5.35 44.7 39.8 84.5 79.6 54.8 76.8

66 5.35 47.9 43.0 91.0 86.0 58.4 84.4

72 5.35 51.7 46.8 98.4 93.5 64.2 92.1

78 5.35 53.6 48.7 102.4 97.5 68.2 102.3

1) ASME, AWWA; flanges ≤ 24 in only available according to ASME, flanges ≥ 28 in only available according to AWWA.
2) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Design", option A "Insertion length short"

B
C
E

D F
A0017284

DN A B E F

[in] [in] [in] [in] [in]

14 5.35 14.1 11.4 21.6

15 5.35 15.1 11.4 23.6

16 5.35 15.1 11.4 23.6

18 5.35 16.2 11.4 23.6

20 5.35 17.2 11.4 23.6

24 5.35 18.8 11.4 23.6

28 5.35 21.6 16.7 27.6

30 5.35 23.0 17.9 29.5

32 5.35 23.6 19.7 31.5

36 5.35 25.6 22.8 35.4

40 5.35 27.5 26.0 39.4

42 5.35 28.9 29.7 41.3

48 5.35 32.0 32.6 47.2

54 5.35 36.4 39.6 53.1

60 5.35 40.4 45.2 59.0

66 5.35 42.4 50.6 64.9

Endress+Hauser 77
Proline Promag W 400

DN A B E F

[in] [in] [in] [in] [in]

72 5.35 44.6 54.2 70.8

78 5.35 49.0 61.8 78.7

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 23.7 24.0 24.3 24.6 24.4 19.3 19.9 20.5 21.0 20.7

15 – – – – 25.9 – – – – 21.7

16 25.8 26.2 26.5 26.9 26.5 21.3 22.2 22.8 23.5 22.8

18 27.9 28.3 28.7 28.7 28.8 23.4 24.2 25.2 25.0 25.2

20 29.9 30.4 31.1 30.9 31.1 25.4 26.4 28.1 27.5 27.8

24 33.7 34.2 35.6 34.8 35.0 29.7 30.7 33.1 32.0 32.5

28 38.5 39.2 39.7 39.8 39.5 33.9 35.2 35.8 36.5 35.8

30 – – – 42.4 42.4 – – – 38.7 39.2

32 43.0 43.8 44.2 44.6 44.6 38.4 40.0 40.4 41.7 41.7

36 46.9 47.7 48.2 48.7 48.9 42.3 43.9 44.3 46.0 46.3

40 50.8 51.9 52.7 53.1 52.4 46.3 48.4 48.2 50.7 49.4

42 – – – 55.6 – – – – 53.0 –

48 59.9 60.8 61.7 62.0 61.5 55.3 57.3 49.4 59.5 58.7

54 – – – 69.6 – – – – 66.3 –

60 – – – 76.9 – – – – 73.0 –

66 – – – 82.4 – – – – 80.0 –

72 84.9 86.3 87.0 87.9 – 80.5 83.3 83.9 86.5 –

78 93.6 94.7 95.6 95.5 – 89.2 91.5 92.3 93.0 –

Order code for "Sensor option", option CA…CE "Corrosion protection"

Option Description

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

CB IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CC IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CD Buried IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 Im2/Im3

CE Buried IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 Im2/Im3

78 Endress+Hauser
Proline Promag W 400

B
D
C L

A0020399

DN A B E

[in] [in] [in] [in]

1 4.41 7.44 7.87

2 4.41 7.44 7.87

3 4.41 8.15 7.87

4 4.41 8.62 9.84

6 4.41 10.0 11.8

8 4.41 11.0 13.8

10 4.41 12.3 17.7

12 4.41 13.3 19.7

Dimension C

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 5.51 4.33 5.51 5.51 – 5.51 5.51

2 – – – 6.50 5.91 6.50 5.91 5.91 6.10 6.10

3 – 7.87 – 7.87 7.48 8.25 7.28 7.28 7.28 7.87

4 – 8.66 – 12.8 9.06 10.0 8.46 8.46 8.27 8.86

6 – 11.2 – 11.8 11.0 12.5 11.0 11.0 11.0 12.0

8 13.4 13.4 14.2 – 13.6 – 13.2 13.2 13.0 13.8

10 15.6 15.9 16.7 – 16.0 – 15.9 15.9 15.8 16.9

12 17.5 18.1 19.1 – 19.1 – 17.9 17.9 17.5 18.9

Dimension D

EN (DIN) ASME AS JIS


DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K
150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

1 – – – 10.2 10.2 10.2 10.2 – 10.2 10.2

2 – – – 10.7 10.4 10.7 10.4 10.4 10.5 10.5

3 – 12.1 – 12.1 11.9 12.2 11.8 11.8 11.8 12.1

Endress+Hauser 79
Proline Promag W 400

Dimension D

EN (DIN) ASME AS JIS

DN PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 10K 20K


150 300

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

4 – 13.0 – 15.0 13.1 13.6 12.9 12.9 12.8 13.1

6 – 15.6 – 15.9 15.5 16.2 15.6 15.6 15.6 16.0

8 17.7 17.7 18.1 – 17.7 – 17.6 17.6 17.5 17.9

10 20.1 20.3 20.7 – 20.3 – 20.3 20.3 20.2 20.8

12 22.0 22.4 22.8 – 22.8 – 22.2 22.2 22.0 22.8

B
D
C
F
E G
A0020435

DN A B C D E F G 1)

[in] [in] [in] [in] [in] [in] [in] [in]

14 4.41 15.6 11.1 26.7 22.2 10.9 21.7

15 4.41 16.6 12.1 28.7 24.2 10.9 23.6

16 4.41 16.6 12.1 28.7 24.2 10.9 23.6

18 4.41 17.6 13.1 30.7 26.2 11.5 25.6

20 4.41 18.6 14.1 32.7 28.2 11.5 25.6

24 4.41 20.6 16.2 36.8 32.3 15.8 30.7

28 4.41 24.6 20.2 44.8 40.3 23.2 35.8

30 4.41 24.6 20.2 44.8 40.3 24.6 38.4

32 4.41 25.5 21.0 46.5 42.0 25.5 40.9

36 4.41 28.5 24.0 52.5 48.0 30.9 46.0

40 4.41 31.5 27.0 58.5 54.0 33.9 51.2

42 4.41 32.5 28.0 60.5 56.0 35.9 53.7

48 4.41 36.4 31.9 68.3 63.8 39.0 61.4

54 4.41 40.4 35.9 76.3 71.8 42.3 69.1

60 4.41 44.3 39.8 84.1 79.6 54.8 76.8

66 4.41 47.5 43.0 90.5 86.0 58.4 84.4

80 Endress+Hauser
Proline Promag W 400

DN A B C D E F G 1)

[in] [in] [in] [in] [in] [in] [in] [in]

72 4.41 51.2 46.8 98.0 93.5 64.2 92.1

78 4.41 53.2 48.7 101.9 97.5 68.2 102.3

1) The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.

Order code for "Design", option A "Insertion length short" and order code for "Sensor option", option
CA…CE "Corrosion protection"

Option Description

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

CB IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CC IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 C5-M/Im1/Im2/Im3

CD Buried IP68, Type 6P, fact-potted; corrosion protection EN ISO 12944 Im2/Im3

CE Buried IP68, Type 6P, cust-potted; corrosion protection EN ISO 12944 Im2/Im3

B
C
E
D F

A0018158

DN A B E F

[in] [in] [in] [in] [in]

14 4.41 13.8 11.4 21.7

15 4.41 14.8 11.4 23.6

16 4.41 14.8 11.4 23.6

18 4.41 15.9 11.4 23.6

20 4.41 16.9 11.4 23.6

24 4.41 18.8 11.4 23.6

28 4.41 21.6 16.7 27.6

30 4.41 23.1 17.9 29.5

32 4.41 23.8 19.7 31.5

36 4.41 25.8 22.8 35.4

40 4.41 27.8 26.0 39.4

42 4.41 29.2 29.7 41.3

Endress+Hauser 81
Proline Promag W 400

DN A B E F

[in] [in] [in] [in] [in]

48 4.41 32.2 32.6 47.2

54 4.41 36.7 39.7 53.2

60 4.41 40.6 45.2 59.1

66 4.41 42.6 50.6 65.0

72 4.41 44.8 54.3 70.9

78 4.41 49.2 61.8 78.7

Dimension C Dimension D

EN (DIN) ASME AS EN (DIN) ASME AS

DN PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA

[in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in]

14 23.4 23.7 24.0 – 24.1 19.3 19.9 20.5 – 20.7

15 – – – – 25.6 – – – – 21.7

16 25.4 25.9 26.2 – 26.2 21.3 22.2 22.8 – 22.8

18 27.6 28.0 28.5 – 28.5 23.4 24.2 25.2 – 25.2

20 29.6 30.0 30.9 – 30.7 25.4 26.4 28.1 – 27.8

24 33.7 34.2 35.4 – 35.1 29.7 30.7 33.1 – 32.5

28 38.5 39.2 39.5 39.8 39.5 33.9 35.2 35.8 36.5 35.8

30 – – – 42.4 42.7 – – – 38.7 39.2

32 43.0 43.8 44.0 44.7 44.7 38.4 40.0 40.4 41.7 41.7

36 47.0 47.8 48.0 48.8 48.9 42.3 43.9 44.3 46.0 46.3

40 50.9 52.0 52.5 53.1 52.5 46.3 48.4 48.2 50.7 49.4

42 – – – 55.7 – – – – 53.0 –

48 59.9 60.9 61.5 62.0 61.6 55.3 57.3 49.4 59.5 58.7

54 – – – 69.8 – – – – 66.3 –

60 – – – 77.1 – – – – 73.0 –

66 – – – 82.6 – – – – 80.0 –

72 85.1 86.5 86.8 88.1 – 80.5 83.3 83.9 86.5 –

78 93.8 95.0 95.4 95.7 – 89.2 91.5 92.3 93.0 –

82 Endress+Hauser
Proline Promag W 400

Accessories

Ground disks for flange connections

DN ≤ 300 (12") DN 300…600 (14…24") DN ≥ 700 (28")


! 9 (0.35) ! 6.4 (0.25)
! 6.5 (0.26)

H
H
H
!B A
!B ! !D !A !D
!A !D

t = 2 (0.08) t = 2 (0.08) t = 2 (0.08)


A0015442

 33 Engineering unit mm (in)

DN Pressure rating A B D H

[in] [in] [in] [in] [in]


1)
1 1.02 2.44 3.05 3.44
1)
1¼ 1.38 3.15 3.44 3.72
1)
1½ 1.61 3.23 3.98 4.06
1)
2 2.05 3.98 4.55 4.25
1)
2½ 2.68 4.76 5.18 4.65
1)
3 3.15 5.16 6.08 5.31
1)
4 4.09 6.14 7.34 6.02
1)
5 5.12 7.36 8.13 6.30
1)
6 6.22 8.54 10.1 7.24
1)
8 8.11 10.5 11.3 8.07
1)
10 10.2 12.9 14.1 9.45
1)
12 12.3 14.8 16.3 10.8

14 DIN, PN 6 13.5 16.5 18.9 14.4

14 DIN, PN 10 13.5 15.8 18.9 14.4

14 ASME, Class 13.5 15.8 18.9 14.4


150

16 DIN, PN 6 15.5 18.5 21.3 15.6

16 DIN, PN 10 15.5 18.5 21.3 15.6

16 ASME, Class 15.5 18.5 21.3 15.6


150

18 DIN, PN 6 17.3 20.7 23.0 16.4

18 DIN, PN 10 17.3 21.1 23.0 16.4

18 ASME, Class 17.3 21.1 23.0 16.4


150

20 DIN, PN 6 19.4 23.3 25.6 18.1

20 DIN, PN 10 19.4 23.2 25.6 18.1

20 ASME, Class 19.4 23.2 25.6 18.1


150

Endress+Hauser 83
Proline Promag W 400

DN Pressure rating A B D H

[in] [in] [in] [in] [in]

24 DIN, PN 6 23.4 27.3 30.2 20.6

24 DIN, PN 10 23.4 27.1 30.2 20.6

24 ASME, Class 23.4 27.1 30.2 20.6


150

28 DIN, PN 6 27.4 – 30.9 18.1

28 DIN, PN 10 27.3 – 32.0 18.9

28 AS, PN 16 27.1 – 31.8 19.3

28 AWWA, Class D 27.3 – 32.8 19.5

30 AWWA, Class D 29.3 – 32.8 20.6

32 DIN, PN 6 31.5 – 35.2 20.5

32 DIN, PN 10 31.3 – 36.2 21.3

32 AS, PN 16 31.1 – 36.0 21.7

32 AWWA, Class D 31.3 – 37.0 22.1

36 DIN, PN 6 35.3 – 39.1 22.4

36 DIN, PN 10 35.2 – 40.2 23.2

36 AS, PN 16 34.9 – 39.9 23.4

36 AWWA, Class D 35.2 – 41.3 24.2

40 DIN, PN 6 39.3 – 43.0 24.4

40 DIN, PN 10 39.2 – 44.4 25.6

40 AS, PN 16 38.9 – 44.5 26.0

40 AWWA, Class D 39.2 – 45.8 26.6

42 AWWA, Class D 41.1 – 48.0 27.7

48 DIN, PN 6 47.4 – 51.6 28.9

1) Ground disks can be used for all the flange standards/pressure ratings which can be supplied in the
standard version.

Weight Compact version


Weight data:
• Including the transmitter
– Order code for "Housing", option M, Q: 1.3 kg (2.9 lb)
– Order code for "Housing", option A, R: 2.0 kg (4.4 lb)
• Excluding packaging material

Weight in SI units

Standard version

EN 1092-1 (DIN 2501)

DN Pressure rating Weight [kg]


[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

25 PN 40 5 5.7

32 PN 40 6 6.7

40 PN 40 8 8.7

50 PN 40 9 9.7

65 PN 16 10 10.7

84 Endress+Hauser
Proline Promag W 400

EN 1092-1 (DIN 2501)

DN Pressure rating Weight [kg]


[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

80 PN 16 12 12.7

100 PN 16 14 14.7

125 PN 16 20 20.7

150 PN 16 24 24.7

200 PN 10 43 43.7

250 PN 10 63 63.7

300 PN 10 68 68.7

350 PN 6 105 105.7

375 PN 6 120 120.7

400 PN 6 120 120.7

450 PN 6 161 161.7

500 PN 6 156 156.7

600 PN 6 208 208.7

700 PN 6 304 304.7

800 PN 6 357 357.7

900 PN 6 485 485.7

1 000 PN 6 589 589.7

1 200 PN 6 850 850.7

1 400 PN 6 1 300 1 300.7

1 600 PN 6 1 700 1 700.7

1 800 PN 6 2 200 2 200.7

2 000 PN 6 2 800 2 800.7

AS 4087, PN 16

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

80 12 12.7

100 14 14.7

150 24 24.7

JIS B2220, 10K

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

25 5 5.7

32 5 5.7

40 6 6.7

50 7 7.7

65 9 9.7

Endress+Hauser 85
Proline Promag W 400

JIS B2220, 10K

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

80 11 11.7

100 13 13.7

125 19 19.7

150 23 23.7

200 40 40.7

250 68 68.7

300 70 70.7

Order code for "Design", option A


Option A "Insertion length short; ISO/DVGW to DN400, DN450-2000 1:1"

EN 1092-1 (DIN 2501)

DN Order code for "Housing", option M, Q


[mm] Polycarbonate plastic 1)

Weight [kg]

PN 6 PN 10 PN 16

450 100 113 139

500 115 133 179

600 156 163 224

700 191 241 288

800 241 316 350

900 309 394 441

1 000 360 469 563

1 200 530 718 840

1 400 785 1 115 1 201

1 600 1 059 1 625 1 842

1 800 1 419 2 108 2 354

2 000 1 878 2 631 2 926

1) Values for aluminum transmitter, AlSi10Mg, coated: + 0.7 kg

AS 2129, Table E

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

450 144 144.7

500 183 183.7

600 261 261.7

700 347 347.7

750 434 434.7

800 494 494.7

900 691 691.7

86 Endress+Hauser
Proline Promag W 400

AS 2129, Table E

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

1 000 762 762.7

1 200 1 238 1 238.7

AS 4087, PN 16

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

450 134 134.7

500 183 183.7

600 261 261.7

700 368 368.7

750 446 446.7

800 504 504.7

900 703 703.7

1 000 760 760.7

1 200 1 220 1 220.7

Order code for "Calibration flow", options H and K, or options H/K or order code for "Sensor option",
option CA

Option Description

H MID Type Examination Cert MI-001

K OIML R49 Class 2

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

EN 1092-1 (DIN 2501)

DN Pressure rating Weight [kg]


[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

25 PN 40 9 9.7

32 PN 40 10 10.7

40 PN 40 11 11.7

50 PN 40 12 12.7

65 PN 16 13 13.7

80 PN 16 15 15.7

100 PN 16 17 17.7

125 PN 16 22 22.7

150 PN 16 27 27.7

200 PN 10 38 38.7

250 PN 10 51 51.7

300 PN 10 60 60.7

Endress+Hauser 87
Proline Promag W 400

AS 2129, PN 16

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

80 15 15.7

100 17 17.7

125 22 22.7

150 27 27.7

JIS B2220, 10K

DN Weight [kg]
[mm]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

25 9 9.7

32 10 10.7

40 10 10.7

50 11 11.7

65 12 12.7

80 13 13.7

100 15 15.7

125 20 20.7

150 25 25.7

200 34 34.7

250 50 50.7

300 57 57.7

Weight in US units

Standard version

ASME B16.5, Class 150

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

1 11 12.5

1½ 18 19.5

2 20 21.5

3 26 27.5

4 31 32.5

6 53 54.5

8 95 96.5

10 161 162.5

12 238 239.5

14 386 387.5

16 452 453.5

18 562 563.5

88 Endress+Hauser
Proline Promag W 400

ASME B16.5, Class 150

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

20 628 629.5

24 893 894.5

AWWA C207, Class D

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

28 882 883.5

30 1 014 1 015.5

32 1 213 1 214.5

36 1 764 1 765.5

40 1 985 1 986.5

42 2 426 2 427.5

48 3 087 3 088.5

54 4 851 4 852.5

60 5 954 5 955.5

66 8 159 8 160.5

72 9 041 9 042.5

78 10 143 10 144.5

Order code for "Design", option A


Option A "Insertion length short; ISO/DVGW to DN400, DN450-2000 1:1"

ASME B16.5, Class 150

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

18 423 424.5

20 505 506.5

24 668 667.5

AWWA C207, Class D

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

28 589 590.5

30 703 704.5

32 847 848.5

36 1 039 1 040.5

40 1 297 1 298.5

42 1 480 1 481.5

Endress+Hauser 89
Proline Promag W 400

AWWA C207, Class D

DN Weight [lbs]
[in]
Order code for "Housing", option M, Q Order code for "Housing", option A, R
Polycarbonate plastic Aluminum, AlSi10Mg, coated

48 1 989 1 990.5

54 2 809 2 810.5

60 3 517 3 518.5

66 4 701 4 702.5

72 5 665 5 666.5

78 6 866 6 867.5

Order code for "Sensor option", option CA


Option CA "IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

ASME B16.5, Class 150

DN Weight
[in] [lbs]

1 17.6

1½ 19.8

2 24.3

3 33.1

4 41.9

6 61.7

8 97.0

10 134.5

12 189.6

Transmitter remote version

Wall-mount housing
Depends on the material of the wall-mount housing:
• Polycarbonate plastic: 1.3 kg (2.9 lb)
• Aluminum, AlSi10Mg, coated: 2.0 kg (4.4 lb)

Sensor remote version


Weight data:
• Including sensor connection housing
• Excluding the connecting cable
• Excluding packaging material

Weight in SI units

Standard version

EN 1092-1 (DIN 2501)

DN Pressure rating Weight


[mm] [kg]

25 PN 40 5

32 PN 40 6

40 PN 40 7

90 Endress+Hauser
Proline Promag W 400

EN 1092-1 (DIN 2501)

DN Pressure rating Weight


[mm] [kg]

50 PN 40 9

65 PN 16 10

80 PN 16 12

100 PN 16 14

125 PN 16 20

150 PN 16 24

200 PN 10 43

250 PN 10 63

300 PN 10 68

350 PN 6 103

375 PN 6 118

400 PN 6 118

450 PN 6 159

500 PN 6 154

600 PN 6 206

700 PN 6 302

800 PN 6 355

900 PN 6 483

1 000 PN 6 587

1 200 PN 6 848

1 400 PN 6 1298

1 600 PN 6 1698

1 800 PN 6 2198

2 000 PN 6 2798

AS 4087, PN 16

DN Weight
[mm] [kg]

80 12

100 14

125 20

150 24

JIS B2220, 10K

DN Weight
[mm] [kg]

25 5

32 5

40 6

50 7

65 9

Endress+Hauser 91
Proline Promag W 400

JIS B2220, 10K

DN Weight
[mm] [kg]

80 11

100 13

125 19

150 23

200 40

250 67

300 70

Order code for "Design", option A


Option A "Insertion length short; ISO/DVGW to DN400, DN450-2000 1:1"

EN 1092-1 (DIN 2501)

DN Weight [kg]
[mm]
PN 6 PN 10 PN 16

450 98 111 139

500 113 131 179

600 154 161 224

700 190 240 288

800 240 315 350

900 308 393 441

1 000 359 468 563

1 200 529 717 840

1 400 784 1 114 1 200

1 600 1 058 1 624 1 841

1 800 1 418 2 107 2 353

2 000 1 877 2 630 2 925

AS 2129, Table E

DN Weight
[mm] [kg]

450 142

500 181

600 259

700 346

750 433

800 493

900 690

1 000 761

1 200 1 237

92 Endress+Hauser
Proline Promag W 400

AS 4087, PN 16

DN Weight
[mm] [kg]

450 132

500 181

600 259

700 367

750 445

800 503

900 702

1 000 759

1 200 1 219

Order code for "Calibration flow", options H and K or order code for "Sensor option", option CA

Option Description

H MID Type Examination Cert MI-001

K OIML R49 Class 2

CA IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M

EN 1092-1 (DIN 2501)

DN Pressure rating [kg]


[mm]

25 PN 40 6.5

32 PN 40 8

40 PN 40 8.5

50 PN 40 10

65 PN 16 11

80 PN 16 13

100 PN 16 15

125 PN 16 20

150 PN 16 25

200 PN 10 36

250 PN 10 49

300 PN 10 58

AS 4087, PN 16

DN [kg]
[mm]

80 13

100 15

150 25

Endress+Hauser 93
Proline Promag W 400

JIS B2220, 10K

DN Weight
[mm] [kg]

25 6.5

32 7.5

40 7.5

50 9

65 10

80 11

100 13

125 18

150 23

200 32

250 48

300 55

Weight in US units

Standard version

ASME B16.5, Class 150

DN Weight
[in] [lbs]

1 11

1½ 15

2 20

3 26

4 31

6 53

8 95

10 161

12 238

14 381

16 448

18 558

20 624

24 889

AWWA C207, Class D

DN Weight
[in] [lbs]

28 878

30 1 010

32 1 208

36 1 760

40 1 980

94 Endress+Hauser
Proline Promag W 400

AWWA C207, Class D

DN Weight
[in] [lbs]

42 2 421

48 3 083

54 4 847

60 5 949

66 8 154

72 9 036

78 10 139

Order code for "Design", option A


Option A "Insertion length short; ISO/DVGW to DN400, DN450-2000 1:1"

ASME B16.5, Class 150

DN Weight
[in] [lbs]

18 420

20 501

24 664

AWWA C207, Class D

DN Weight
[in] [lbs]

28 587

30 701

32 845

36 1 036

40 1 294

42 1 477

48 1 987

54 1 273

60 3 515

66 4 699

72 5 662

78 6 864

Order code for "Sensor option", option CA


Option CA "IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M"

ASME B16.5, Class 150

DN Weight
[in] [lbs]

1 13

1½ 15.5

2 20

Endress+Hauser 95
Proline Promag W 400

ASME B16.5, Class 150

DN Weight
[in] [lbs]

3 29

4 37

6 57

8 93

10 130

12 185

Measuring tube specification Nominal diameter Pressure rating Measuring tube internal diameter

EN (DIN) ASME AS 2129 JIS Hard rubber Polyurethane

AWWA AS 4087

[mm] [in] [mm] [in] [mm] [in]

25 1 PN 40 Class 150 – 20K – – 24 0.94

32 – PN 40 – – 20K – – 32 1.26

40 1½ PN 40 Class 150 – 20K – – 38 1.50

50 2 PN 40 Class 150 Table E, PN 16 10K 50 1.97 50 1.97

65 – PN 16 – – 10K 66 2.60 66 2.60

80 3 PN 16 Class 150 Table E, PN 16 10K 79 3.11 79 3.11

100 4 PN 16 Class 150 Table E, PN 16 10K 102 4.02 102 4.02

125 – PN 16 – – 10K 127 5.00 127 5.00

150 6 PN 16 Class 150 Table E, PN 16 10K 156 6.14 156 6.14

200 8 PN 10 Class 150 Table E, PN 16 10K 204 8.03 204 8.03

250 10 PN 10 Class 150 Table E, PN 16 10K 258 10.2 258 10.2

300 12 PN 10 Class 150 Table E, PN 16 10K 309 12.2 309 12.2

350 14 PN 6 Class 150 Table E, PN 16 – 342 13.5 342 13.5

375 15 – – PN 16 – 392 15.4 – –

400 16 PN 6 Class 150 Table E, PN 16 – 392 15.4 392 15.4

450 18 PN 6 Class 150 – – 437 17.2 437 17.2

500 20 PN 6 Class 150 Table E, PN 16 – 492 19.4 492 19.4

600 24 PN 6 Class 150 Table E, PN 16 – 594 23.4 594 23.4

700 28 PN 6 Class D Table E, PN 16 – 692 27.2 692 27.2

750 30 – Class D Table E, PN 16 – 742 29.2 742 29.2

800 32 PN 6 Class D Table E, PN 16 – 794 31.3 794 31.3

900 36 PN 6 Class D Table E, PN 16 – 891 35.1 891 35.1

1 000 40 PN 6 Class D Table E, PN 16 – 994 39.1 994 39.1

– 42 – Class D – – 1 043 41.1 1 043 41.1

1 200 48 PN 6 Class D Table E, PN 16 – 1 197 47.1 1 197 47.1

– 54 – Class D – – 1 339 52.7 – –

1 400 – PN 6 – – – 1 402 55.2 – –

– 60 – Class D – – 1 492 58.7 – –

1 600 – PN 6 – – – 1 600 63.0 – –

– 66 – Class D – – 1 638 64.5 – –

96 Endress+Hauser
Proline Promag W 400

Nominal diameter Pressure rating Measuring tube internal diameter

EN (DIN) ASME AS 2129 JIS Hard rubber Polyurethane

AWWA AS 4087

[mm] [in] [mm] [in] [mm] [in]

1 800 72 PN 6 Class D – – 1 786 70.3 – –

2 000 78 PN 6 Class D – – 1 989 78.3 – –

Materials Transmitter housing

Compact version, standard


• Order code for "Housing", option A "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option M: polycarbonate plastic
• Window material:
– For order code for "Housing", option A: glass
– For order code for "Housing", option M: plastic

Compact version, inclined


• Order code for "Housing", option R "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option Q: polycarbonate plastic
• Window material:
– For order code for "Housing", option R: glass
– For order code for "Housing", option Q: plastic

Remote version (wall-mount housing)


• Order code for "Housing", option P "Compact, aluminum coated":
Aluminum, AlSi10Mg, coated
• Order code for "Housing", option N: polycarbonate plastic
• Window material:
– For order code for "Housing", option P: glass
– For order code for "Housing", option N: plastic

Cable entries/cable glands

3
A0020640

 34 Possible cable entries/cable glands


1 Cable entry in transmitter housing, wall-mount housing or connection housing with internal thread M20 x
1.5
2 Cable gland M20 x 1.5
3 Adapter for cable entry with internal thread G ½" or NPT ½"

Endress+Hauser 97
Proline Promag W 400

Compact and remote versions and sensor connection housing

Cable entry/cable gland Material

Cable gland M20 × 1.5 Plastic

Remote version: cable gland M20 × 1.5 • Sensor connection housing:


Nickel-plated brass
Option of reinforced connecting cable
• Transmitter wall-mount housing:
Plastic

Adapter for cable entry with internal thread G ½" or Nickel-plated brass
NPT ½"

Device plug

Electrical connection Material

Plug M12x1 • Socket: Stainless steel, 1.4404 (316L)


• Contact housing: Polyamide
• Contacts: Gold-plated brass

Connecting cable for remote version


Electrode and coil current cable
• Standard cable: PVC cable with copper shield
• Reinforced cable: PVC cable with copper shield and additional steel wire braided jacket

Sensor housing
• DN 25 to 300 (1 to 12"):
– Aluminum, AlSi10Mg, coated
– Carbon steel with Al/Zn protective coating
• DN 50 to 300 (2 to 12"):
Carbon steel with protective varnish (IP68)
• DN 350 to 2000 (14 to 78"):
Carbon steel with protective varnish

Sensor connection housing


• Standard: aluminum, AlSi10Mg, coated (IP66/67)
• Option:
– Polycarbonate for IP68 with DN 50 to 300 (2 to 12")
– Polycarbonate for order code "Sensor option", option CA…CE "Corrosion protection" with DN 350
to 2000 (14 to 78")

Measuring tubes
• DN 25 to 300 (1 to 12") 1): stainless steel, 1.4301/1.4306/304/304L
• DN 350 to 1200 (14 to 48") 1): stainless steel, 1.4301/304
• DN 1350 to 2000 (54 to 78") 1): stainless steel, 1.4301 similar to 304

Liner
• DN 25 to 1200 (1 to 48"): polyurethane
• DN 50 to 2000 (2 to 78"): hard rubber

Electrodes
• Stainless steel, 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)
• Tantalum

1) For carbon steel flange material with Al/Zn protective coating (DN 25 to 300 (1 to 12")), protective varnish (IP68) (DN 50 to 300 (2 to 12")) or
protective varnish ≥ DN 350 (14")

98 Endress+Hauser
Proline Promag W 400

Process connections

EN 1092-1 (DIN 2501)


• DN 25 to 1200 1):
– Stainless steel, 1.4404/1.4571/F316L
– Carbon steel, A105/FE410WB/P250GH/S235JRG2/S235JR+N
• DN 1350 to 2000 1):
– Stainless steel ,1.4404/1.4571
– Carbon steel, P250GH/S235JRG2
• DN 450 to 2000 2):
Carbon steel, A105/S235JRG2
EN 1092-1 (DIN 2501), PN6:
DN 350 to 1000 1):
Carbon steel, A105/FE410WB/S235JRG2

ASME B16.5
• DN 25 to 1200 (1 to 48"):
Stainless steel, F316L similar to 1.4404
• DN 25 to 300 (1 to 12") 2):
Carbon steel, A105 similar to 1.0432
• DN 350 to 1200 (14 to 48") 2):
Carbon steel, A105/A515 Grade 70

AWWA C207
• DN 48":
Carbon steel, A105/A181/P265GH/S275JR
• DN 54 to 72":
Carbon steel, P265GH similar to 1.0425
• DN 48 to 78" 2):
Carbon steel, A105/A181/P265GH/S275JR

AS 2129
• DN 50 to 1200:
Carbon steel, A105/S235JRG2
• DN 350 to 1200 2):
Carbon steel, A105/FE410WB/P235GH/P265GH/S235JRG2

AS 4087
• DN 50 to 1200:
Carbon steel, A105/S275JR
• DN 350 to 1200 2):
Carbon steel, A105/P265GH/S275JR

JIS B2220
• Stainless steel, F316L similar to 1.4404
• Carbon steel, A105/A350LF2 1)

Seals
In accordance with DIN EN 1514-1

Accessories

Display protection
Stainless steel, 1.4301 (304L)

2) Order Code for "Design", Option A "Insertion length short"

Endress+Hauser 99
Proline Promag W 400

Ground disks
• Stainless steel, 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)
• Tantalum

Fitted electrodes Measurement, reference and empty pipe detection electrodes available as standard with:
• 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)
• Tantalum
Optionally available with DN 350 to 2000 (14 to 78"):
Exchangeable measuring electrodes made from 1.4435 (316L)

Process connections • EN 1092-1 (DIN 2501) 3)


– DN ≤ 300: fixed flange (PN 10/16/25/40) = form A
– DN ≥ 350: fixed flange (PN 6/10/16/25) = flat face
– DN 450 to 2000 4): fixed flange (PN 6/10/16) = flat face
• ASME B16.5
– DN 25 to 600 (1 to 24"): fixed flange (Class 150)
– DN 350 to 2000 (14 to 78") 4): fixed flange (Class 150)
– DN 25 to 150 (1 to 6"): fixed flange (Class 300)
• AWWA C207
– DN 48 to 72": fixed flange (Class D)
– DN 48 to 78" 4): fixed flange (Class D)
• AS 2129
– DN 50 to 1200: fixed flange (Table E)
– DN 350 to 1200 4): fixed flange (Table E)
• AS 4087
– DN 50 to 1200): fixed flange (PN 16)
– DN 350 to 1200 4): fixed flange (PN 16)
• JIS B2220
– DN 50 to 300: fixed flange (10K)
– DN 25 to 300: fixed flange (20K)
For information on the materials of the process connections →  99

Surface roughness Electrodes with 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum:
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)

Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Quick and safe commissioning
• Guided menus ("Make-it-run" wizards) for applications
• Menu guidance with brief explanations of the individual parameter functions

3) Dimensions as per DIN 2501, DN 65 (2 ½") PN 16 and DN 600 (24") PN 16 only as per EN 1092-1
4) Order code for "Design", option A "Insertion length short"

100 Endress+Hauser
Proline Promag W 400

Reliable operation
• Operation in the following languages:
– Via local display:
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
– Via "FieldCare" operating tool:
English, German, French, Spanish, Italian, Chinese, Japanese
– Via integrated Web browser (only available for device versions with HART, PROFIBUS DP and
EtherNet/IP):
English, German, French, Spanish, Italian, Dutch, Portuguese, Polish, Russian, Turkish, Chinese,
Japanese, Bahasa (Indonesian), Vietnamese, Czech
• Uniform operating philosophy applied to device, operating tools and Web browser
• If replacing the electronic module, transfer the device configuration via the plug-in memory
(HistoROM DAT) which contains the process and measuring device data and the event logbook. No
need to reconfigure.
Efficient diagnostics increase measurement availability
• Troubleshooting measures can be called up via the device, operating tools and Web browser
• Diverse simulation options, logbook for events that occur and optional line recorder functions
In custody transfer mode, operation is only possible to a limited extent once the device has been
put into circulation or has been lead-sealed.

Local operation Via display module

A0020538

Display elements
• 4-line display
• White background lighting; switches to red in event of device errors
• Format for displaying measured variables and status variables can be individually configured
• Permitted ambient temperature for the display: –20 to +50 °C (–4 to +122 °F)
The readability of the display may be impaired at temperatures outside the temperature range.
Operating elements
External operation via touch control; 3 optical keys: , , E

Additional functionality
• Data backup function
The device configuration can be saved in the display module.
• Data comparison function
The device configuration saved in the display module can be compared to the current device
configuration.
• Data transfer function
The transmitter configuration can be transmitted to another device using the display module.

Remote operation Via HART protocol


This communication interface is available in device versions with a HART output.

Endress+Hauser 101
Proline Promag W 400

4 6 7

1 2 3 5
A0017124

 35 Options for remote operation via HART protocol


1 Control system (e.g. PLC)
2 Field Communicator 475
3 Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM)
4 Commubox FXA195 (USB)
5 Field Xpert SFX350 or SFX370
6 VIATOR Bluetooth modem with connecting cable
7 Transmitter

Via PROFIBUS DP network


This communication interface is available in device versions with PROFIBUS DP.

1 2

4 4 4
A0020903

 36 Options for remote operation via PROFIBUS DP network


1 Automation system
2 Computer with PROFIBUS network card
3 PROFIBUS DP network
4 Measuring device

Via Ethernet-based fieldbus


This communication interface is available in device versions with EtherNet/IP.

102 Endress+Hauser
Proline Promag W 400

1 2 3

5 5 5
A0016961

 37 Options for remote operation via Ethernet-based fieldbus


1 Control system, e.g. "RSLogix" (Rockwell Automation)
2 Workstation for measuring device operation: with Add-on Profile Level 3 for "RSLogix 5000" (Rockwell
Automation) or with Electronic Data Sheet (EDS)
3 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
4 Ethernet switch
5 Measuring device

Service interface Via service interface (CDI-RJ45)


This communication interface is present in the following device version:
• Order code for "Output", option H: 4-20/0-20 mA HART, pulse/frequency/switch output
• Order code for "Output", option I: 4-20/0-20 mA HART, pulse/frequency/switch output, status
input
• Order code for "Output", option L: PROFIBUS DP
• Order code for "Output", option N: EtherNet/IP
• Order code for "Output", option M: Modbus RS485

HART

1 2 3

A0020481

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

Endress+Hauser 103
Proline Promag W 400

PROFIBUS DP

1 2 3

A0023114

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

EtherNet/IP

1 2 3

A0023113

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

104 Endress+Hauser
Proline Promag W 400

Modbus RS485

1 2 3

A0023114

1 Computer with Web browser (e.g. Internet Explorer) for accessing the integrated device Web server or with
"FieldCare" operating tool with COM DTM "CDI Communication TCP/IP"
2 Standard Ethernet connecting cable with RJ45 plug
3 Service interface (CDI -RJ45) of the measuring device with access to the integrated Web server

Certificates and approvals


CE mark The measuring system is in conformity with the statutory requirements of the applicable EC
Directives. These are listed in the corresponding EC Declaration of Conformity along with the
standards applied.
Endress+Hauser confirms successful testing of the device by affixing to it the CE mark.

C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media
Authority (ACMA)".

Ex approval The measuring device is certified for use in hazardous areas and the relevant safety instructions are
provided in the separate "Safety Instructions" (XA) document. Reference is made to this document on
the nameplate.
The separate Ex documentation (XA) containing all the relevant explosion protection data is
available from your Endress+Hauser sales center.

ATEX, IECEx
Currently, the following versions for use in hazardous areas are available:

Drinking water approval • ACS


• KTW/W270
• NSF 61
• WRAS BS 6920

Certification PROFIBUS PROFIBUS interface


The measuring device is certified and registered by the PROFIBUS User Organization (PNO). The
measuring system meets all the requirements of the following specifications:
• Certified in accordance with PROFIBUS PA Profile 3.02
• The device can also be operated with certified devices of other manufacturers (interoperability)

Modbus RS485 certification The measuring device meets all the requirements of the MODBUS/TCP conformity test and has the
"MODBUS/TCP Conformance Test Policy, Version 2.0". The measuring device has successfully passed
all the test procedures carried out and is certified by the “MODBUS/TCP Conformance Test
Laboratory” of the University of Michigan.

Endress+Hauser 105
Proline Promag W 400

EtherNet/IP certification The measuring device is certified and registered by the ODVA (Open Device Vendor Association).
The measuring system meets all the requirements of the following specifications:
• Certified in accordance with the ODVA Conformance Test
• EtherNet/IP Performance Test
• EtherNet/IP PlugFest compliance
• The device can also be operated with certified devices of other manufacturers (interoperability)

Measuring instrument Promag W 400 is (optionally) approved as a cold water meter (MI‐001) for volume measurement in
approval service subject to legal metrological control in accordance with the European Measuring Instruments
Directive 2004/22/EC (MID).
Promag W 400 is qualified to OIML R49 and has an OIML Certificate of Conformity (optional).

Other standards and • EN 60529


guidelines Degrees of protection provided by enclosures (IP code)
• EN 61010-1
Safety requirements for electrical equipment for measurement, control and laboratory use
• IEC/EN 61326
Emission in accordance with Class A requirements. Electromagnetic compatibility (EMC
requirements).
• ANSI/ISA-61010-1 (82.02.01): 2004
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part
1 General Requirements
• CAN/CSA-C22.2 No. 61010-1-04
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use - Part
1 General Requirements
• NAMUR NE 21
Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment
• NAMUR NE 32
Data retention in the event of a power failure in field and control instruments with
microprocessors
• NAMUR NE 43
Standardization of the signal level for the breakdown information of digital transmitters with
analog output signal.
• NAMUR NE 53
Software of field devices and signal-processing devices with digital electronics
• NAMUR NE 105
Specifications for integrating fieldbus devices in engineering tools for field devices
• NAMUR NE 107
Self-monitoring and diagnosis of field devices
• NAMUR NE 131
Requirements for field devices for standard applications

Ordering information
Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser web site: www.endress.com → Choose your
country → Products → Select measuring technology, software or components → Select product
(picklists: measurement method, product family etc.) → Device support (right-hand column):
Configure the selected product → The Product Configurator for the selected product is opened.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop

106 Endress+Hauser
Proline Promag W 400

Product generation index Release date Product root Modification

01.06.2012 8S1B Original

01.01.2015 8S1C DN 08 to 50 measuring tube material 1.4435/316L


DN 40 to 50 reduction in length
DN 40 to 50 reduction in weight

Additional information is available from your sales center or at:


www.service.endress.com → Downloads

Application packages
Many different application packages are available to enhance the functionality of the device. Such
packages might be needed to address safety aspects or specific application requirements.
The application packages can be ordered with the device or subsequently from Endress+Hauser.
Detailed information on the order code in question is available from your local Endress+Hauser sales
center or on the product page of the Endress+Hauser website: www.endress.com.

Cleaning Package Description

Electrode cleaning circuit The electrode cleaning circuit (ECC) function has been developed to have a solution
(ECC) for applications where magnetite (Fe3O4) deposits frequently occur (e.g. hot
water). Since magnetite is highly conductive this build up leads to measuring errors
and ultimately to the loss of signal. The application package is designed to AVOID
build up of highly conductive matter and thin layers (typical of magnetite).

Diagnostics functions Package Description

HistoROM extended Comprises extended functions concerning the event log and the activation of the
function measured value memory.
Event log:
Memory volume is extended from 20 message entries (basic version) to up to 100
entries.
Data logging (line recorder):
• Memory capacity for up to 1000 measured values is activated.
• 250 measured values can be output via each of the 4 memory channels. The
recording interval can be defined and configured by the user.
• Data logging is visualized via the local display or FieldCare.

Heartbeat Technology Package Description

Heartbeat Verification Heartbeat Monitoring:


+Monitoring Continuously supplies monitoring data, which are characteristic of the measuring
principle, for an external condition monitoring system. This makes it possible to:
• Draw conclusions - using these data and other information - about the impact
the measuring application has on the measuring performance over time.
• Schedule servicing in time.
• Monitor the product quality, e.g. gas pockets.
Heartbeat Verification:
Makes it possible to check the device functionality on demand when the device is
installed, without having to interrupt the process.
• Access via onsite operation or other operating interfaces, such as FieldCare for
instance.
• End-to-end, traceable documentation of the verification results, including report.
• Makes it possible to extend calibration intervals in accordance with operator's
risk assessment.

Endress+Hauser 107
Proline Promag W 400

Accessories
Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are
available for the device. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.

Device-specific accessories For the transmitter

Accessories Description

Display protection Is used to protect the display against impact or scoring from sand in desert areas.

 For details, see Special Documentation SD00333F


Connecting cable for Coil current and electrode cables, various lengths, reinforced cables available on
remote version request.

Ground cable Set, consisting of two ground cables for potential equalization.

Post mounting kit Post mounting kit for transmitter.

Compact → remote For converting a compact device version to a remote device version.
conversion kit

Promag 50/53 → Promag For converting a Promag with transmitter 50/53 to a Promag 400.
400 conversion kit

For the sensor

Accessories Description

Ground disks Are used to ground the fluid in lined measuring tubes to ensure proper
measurement.

 For details, see Installation Instructions EA00070D


Communication-specific Accessories Description
accessories
Commubox FXA195 For intrinsically safe HART communication with FieldCare via the USB interface.
HART
 For details, see "Technical Information" TI00404F
HART Loop Converter Is used to evaluate and convert dynamic HART process variables to analog current
HMX50 signals or limit values.

 BA00371F
For details, see "Technical Information" TI00429F and Operating Instructions

Wireless HART adapter Is used for the wireless connection of field devices.
SWA70 The WirelessHART adapter can be easily integrated into field devices and existing
infrastructures, offers data protection and transmission safety and can be operated
in parallel with other wireless networks with minimum cabling complexity.

 For details, see Operating Instructions BA00061S


Fieldgate FXA320 Gateway for the remote monitoring of connected 4-20 mA measuring devices via a
Web browser.

 BA00053S
For details, see "Technical Information" TI00025S and Operating Instructions

Fieldgate FXA520 Gateway for the remote diagnostics and remote configuration of connected HART
measuring devices via a Web browser.

 For details, see "Technical Information" TI00025S and Operating Instructions


BA00051S

108 Endress+Hauser
Proline Promag W 400

Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area.

 For details, see Operating Instructions BA01202S


Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
Fieldbus devices in the non-Ex area and the Ex area.

 For details, see Operating Instructions BA01202S


Service-specific accessories Accessories Description

Applicator Software for selecting and sizing Endress+Hauser measuring devices:


• Calculation of all the necessary data for identifying the optimum flowmeter: e.g.
nominal diameter, pressure loss, accuracy or process connections.
• Graphic illustration of the calculation results
Administration, documentation and access to all project-related data and
parameters throughout the entire life cycle of a project.
Applicator is available:
• Via the Internet: https://wapps.endress.com/applicator
• On CD-ROM for local PC installation.

W@M Life cycle management for your plant


W@M supports you with a wide range of software applications over the entire
process: from planning and procurement, to the installation, commissioning and
operation of the measuring devices. All the relevant device information, such as
the device status, spare parts and device-specific documentation, is available for
every device over the entire life cycle.
The application already contains the data of your Endress+Hauser device. Endress
+Hauser also takes care of maintaining and updating the data records.
W@M is available:
• Via the Internet: www.endress.com/lifecyclemanagement
• On CD-ROM for local PC installation.

FieldCare FDT-based plant asset management tool from Endress+Hauser.


It can configure all smart field units in your system and helps you manage them. By
using the status information, it is also a simple but effective way of checking their
status and condition.

 For details, see Operating Instructions BA00027S and BA00059S


Commubox FXA291 Connects Endress+Hauser field devices with a CDI interface (= Endress+Hauser
Common Data Interface) and the USB port of a computer or laptop.

 For details, see "Technical Information" TI00405C


System components Accessories Description

Memograph M graphic The Memograph M graphic display recorder provides information on all relevant
display recorder measured variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on a SD card or USB stick.

 BA00247R
For details, see "Technical Information" TI00133R and Operating Instructions

Endress+Hauser 109
Proline Promag W 400

Documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• The CD-ROM provided for the device (depending on the device version, the CD-ROM might
not be part of the delivery!)
• The W@M Device Viewer : Enter the serial number from the nameplate
(www.endress.com/deviceviewer)
• The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.

Standard documentation Brief Operating Instructions

Measuring device Documentation code

Promag W 400 KA01114D

Operating Instructions

Measuring device Documentation code

HART PROFIBUS DP Modbus RS485 EtherNet/IP

Promag W 400 BA01063D BA01234D BA01231D BA01214D

Supplementary device- Special documentation


dependent documentation
Contents Documentation code

Modbus RS485 Register Information SD01379D

Heartbeat Technology SD01183D

Information on Custody Transfer Measurement SD01230D

Installation Instructions

Contents Documentation code

Installation Instructions for spare part sets Specified for each individual accessory

Registered trademarks
HART®
Registered trademark of the HART Communication Foundation, Austin, USA
PROFIBUS®
Registered trademark of the PROFIBUS User Organization, Karlsruhe, Germany
Modbus®
Registered trademark of SCHNEIDER AUTOMATION, INC.
EtherNet/IPTM
Trademark of ODVA, Inc.
Microsoft®
Registered trademark of the Microsoft Corporation, Redmond, Washington, USA
Applicator®, FieldCare®, Field XpertTM, HistoROM®, Heartbeat TechnologyTM
Registered or registration-pending trademarks of the Endress+Hauser Group

110 Endress+Hauser
www.addresses.endress.com