D-11112-2010
ONE DEVICE FOR INVASIVE AND EXCELLENT SPONTANEOUS BREATHING:
NON-INVASIVE THERAPY: Savina 300 Select and Savina 300 Classic
The Savina® 300 Select and Savina® 300 offers you state-of-the-art mask ventilation
Classic simplifies the continuous imple- with stress-free spontaneous breathing
mentation of an optimal ventilation strategy: with excellent trigger response time thanks
The NIV option means that non-invasive to the turbine and its continuous high flow
ventilation can be applied in all modes and delivery of up to 280 l/min.
whenever the patient is ready for it, with-
out the need to change devices. Should SENSITIVE LEAK COMPENSATION:
intubation be necessary the therapist can Leak compensation is an essential part of
D-12295-2016 / D-12306-2016
quickly and easily switch to an invasive mask ventilation therapy. With leakage
ventilation mode. compensation the flow-trigger sensitivity is
adjusted according to leak size. In vol-
NIV HELPS REDUCE INTUBATION TIME: ume-controlled modes, the patient always
Intubation has been linked to an increased receives the set Vt. In pressure-controlled
risk for the development of ventilator-asso- modes, the set pressure levels are
Savina® 300 Select /
ciated pneumonia 2, weaning problems continuously maintained. Even in the Savina® 300 Classic
and patient discomfort. Due to these risks, presence of large leaks, the Savina 300
both intubation and invasive ventilation ventilators flexible leak compensation
should be avoided whenever possible. system continuously provides the exact
NIV helps to avoid re-intubation and short- amount of breathing gas needed to com-
en recovery times1,4. plement the patient’s flow demand.
The use of NIV has been expanded to INCREASED PATIENT SAFETY AND 1 F errer M; Am J Respir Crit Care Med Vol 168.
intensive care applications, including the IMPROVED COMFORT: pp 1438–1444, 2003
treatment of acute chronic respiratory When mask ventilation is selected, alarms 2 Collard HR, MD; Sanjay Saint, MD. Prevention
failure3. It is an excellent choice for inter- which are not applicable will not be dis- of Ventilator-Associated Pneumonia
mittent application when partial respiratory played. In order to avoid artefacts, various 3 Becker H F, Schönhofer B, Burchardi H. Nicht
support is needed. alarm settings may be deactivated (MV invasive Beatmung. Vorwort, S 59; Thieme 2005
low, Vti high and Apnea monitoring). For 4 Ram FSF et al, The Cochrane Library 2005,
NIV applied as a weaning method in improved patient safety, a clearly visible Issue 4
COPD enables faster weaning and has a displayed message alerts the user to any 5 N ava S, Ambrosio N, Clini E, et. al.
positive effect on mortality rates5. deactivated alarms. Ann Intern Med. 128: 721 – 728; 1998
| 02
D-28635-2015
D-13571-2010
therapy, even in case of mouth breathing. contours. Also in the case of facial abnormalitie‘s the total-
face mask is the first choice.
Not all products, features, or services are for sale in all countries.
Mentioned Trademarks are only registered in certain countries and not necessarily in the country
in which this material is released. Go to www.draeger.com/trademarks to find the current status.
CORPORATE HEADQUARTERS REGION DACH REGION MIDDLE EAST, AFRICA REGION NORTH AMERICA
Drägerwerk AG & Co. KGaA Drägerwerk AG & Co. KGaA Drägerwerk AG & Co. KGaA Draeger, Inc.
Moislinger Allee 53–55 Moislinger Allee 53–55 Branch Office 3135 Quarry Road
23558 Lübeck, Germany 23558 Lübeck, Germany P.O. Box 505108 Telford, PA 18969-1042, USA
Tel +49 451 882 0 Dubai, United Arab Emirates Tel +1 800 4DRAGER
www.draeger.com Fax +49 451 882 2080 Tel +971 4 4294 600 (+1 800 437 2437)
info@draeger.com Fax +971 4 4294 699 Fax +1 215 723 5935
contactuae@draeger.com info.usa@draeger.com
REGION EUROPE
Manufacturer: Drägerwerk AG & Co. KGaA REGION ASIA / PACIFIC REGION CENTRAL
Drägerwerk AG & Co. KGaA Moislinger Allee 53–55 Draeger Singapore Pte. Ltd. AND SOUTH AMERICA
Moislinger Allee 53–55 23558 Lübeck, Germany 25 International Business Park Dräger Panama Comercial
23558 Lübeck, Germany Tel +49 451 882 0 #04-20/21 German Centre S. de R.L.
Fax +49 451 882 2080 Singapore 609916 Complejo Business Park,
info@draeger.com Tel +65 6308 9400 V tower, 10th floor
Fax +65 6308 9401 Panama City
asia.pacific@draeger.com Tel +507 377 9100
Fax +507 377 9130
contactcsa@draeger.com
Locate your Regional Sales
Representative at:
www.draeger.com/contact