THREE PHASE INDUCTION MOTOR SPECIFICATION

Customer :
End user : PT Chandra Asri Date : 12-May-17
Quotation No. : ADE6698 Sign : 2-setsu-1
No. 1 2
1 Application Reciprocating Compressor
2 No. of units 1
3 Preliminary outline drawing No. Q/#:ADE6698-1
4 Type and Form ICFT-CHW
5 Rotor construction Cage rotor
6 IP grade Enclosure IP44 IC611 (TEAAC)
7 Mounting method Coupling method Horizontal Foot (IMB3) Direct
8 Rated output(kW) Service factor 850 1.00
R A T I N G

9 Number of poles Synchronous rpm 16 380


10 Rated voltage(V) Frequency(Hz) 6000 50
11 Insulation class Temperature rise (degC) F B rise
12 Min. amb. temp (degC) Max. amb. temp (degC) -20 40
13 Altitude (m) Not specified
14 Specified locked rotor current (%) Not specified -
15 Specified Eff (%) Specified P.F. (%) Not specified Not specified
16 Applicable standard IEC 60034-1 TEST: IEC 60034 Equivalent circuit
17 Frame size 560-1800
18 Approximate net weight (kg) 12000
19 Starting method Min. start volt (%) D.O.L -
20 Direction of rotation Not specified CCW viewed from DE
21 Location Treatment Outdoor Corrosion-proof Grade 2
22 Standard / Area class Certifying body / Ex-type NEC ClI.Div2.Gr.C/D NEC Nonsparking w/o certificate
23 Specified noise level @ No-Load dB(A) SPL 85@Commercial frequency
24 Cooling water grade Cooling water vol.(l/min) - -
25 Specified LRT (%) Specified BDT (%) Not specified Not specified
26 Load GD2(kg-m2) 5300
L O A D

27 Up thrust Nom/Max (kN) Down thrust Nom/Max (kN) None None


28 Radial load Static/Dinamic(kN) Load position (mm) None / None -
29 Starting duty Not specified
30 Shaft end specification Flange shaft
31 Vibration level None
32 N.D.E bearing D.E bearing Sleeve Oil
B R G.

33 Lubricant Req. oil and pressure ISO VG68 Turbine oil -


34 N.D.E lub. method D.E lub. method Self cooled Self cooled
35 Type of main terminal box. Not specified
36 Main terminal arrangement Not specified
A C C E S S O R Y

37 Main cable entrance arrangement Not specified


38 Location of main terminal box Not specified
39 Mount coupling or pulley None
40 Motor base None
41 Anchor bolts Shim pack None None
42 Space heater Low temp.type (1phase, 220V)
43 Stator temperature detectors RTD (Pt 0 degC-100 ohm x 6)
44 Bearing temperature detectors RTD for hazardous area (Pt 0 degC-100 ohm x 2)
45 Vibration sensors None
46 Other specified accessories Earth bonding

Shaft end key Yes


47 Supplied parts and utility by customer None

48 Spare parts or Special tools None

49 Other Specific Requirements Epoxy & Polyurethane75micrometers


Replace motor
R E M A R K

Heat exchanger tubes made of stainless steel (SS 304)


RTD leads terminated in common box
      Current pulsation ratio less 66%
  Replace motor(SN:9410119,O/#:EP22549RK0001 )
 

TMEIC No. : ADE6698


ELECTRICAL PERFORMANCE DATA
(DESIGN VALUE)
TMEIC quotation No. : ADE6698
Messrs. : / PT Chandra Asri 1st. Issue : 12-May-17

Item Item No. 1 2 3 4 5 Remarks


1 Motor No. -

2 Quantity unit(s) 1
ICFT-
3 Enclosure -
CHW
4 Number of poles - 16

5 Rated output kW 850

6 Rated voltage V 6000

7 Rated frequency Hz 50

8 Insulation class - F

9 Temperature rise deg.C B rise by RTD

10 Frame size - 560-1800

11 Approx. Mass kg 12000

12 Rated speed rpm 370

13 Rated current A 122

14 Locked rotor current % 550 Design value


at 100% Load % - Guaranteed value
at 100% Load % 94.5 Design value by
15 Efficiency IEC 60034 Equivalent circuit
Equivalent circuit method
at 100% Load % - Guaranteed value
at 100% Load % 71.0 Design value by
16 Power factor IEC 60034 Equivalent circuit
Equivalent circuit method
17 Locked rotor torque % 80 Design value

18 Pull-up torque % 80

19 Breakdown torque % 180 Design value

20 Rotor GD2 kgm2 1200


Guarenteed at no-load from
21 Sound pressure level dB(A) 85
1m (Average of 4 key points)
22 Safe stall time ( Hot / Cold ) s 10 / 14
23 Remarks

[Note] This datasheet shows 1) design value (not guaranteed).


2) data for sine wave power. Design by
TMEIC TM21-H SERIES SQUIRREL CAGE INDUCTION MOTOR SUBMITTED DATE May.12.17
HIGH VOLTAGE CLASS F INSULATION Q/# ADE6698-1

計画外形図
PRELIMINARY OUTLINE
全閉外扇形 自冷すべり軸受
TOTALLY ENCLOSED AIR TO AIR COOLED TYPE
SELF COOLED SLEEVE BEARINGS

極数 出力 回転数 電圧 周波数 絶縁 運転
POLE OUTPUT (kW) FL. SPEED (min-1) VOLTAGE Hz INSU. DUTY
16 850 370 6000 50 F S1

寸法
DIMENSIONS
極数 枠番
POLE FRAME SIZE

16 560-1800

単位
C (D) D (AB+P/2) 2E 2F H (O) J K KL (AB) L (C) M (A) N (B) P (P/2) Z (H)
UNIT

mm 560 2160 1000 1800 2390 225 240 1370 4265 1260 2280 790 68

単位 軸受 BEARING 重量
UNIT DRIVE END NON DRIVE END APPROX WT.

mm S.C.SLEEVE S.C.SLEEVE 12000 (kg)

参考用図面のため、据付確定図として利用する場合は当社へ御問合せ下さい。
DIMENSIONS ARE FOR REFERENCE ONLY, CONSULT TMEIC FOR CERTIFIED DIMENSIONS.

TOKYO-JAPAN
TESTS ITEM LIST (for 1st. Unit) Based on IEC-60034
Applicable standards Factory Witness Test
No. Test and Inspection Items
or specifications Test Test Report
1 Visual inspection MFR standard Yes No No
2 Dimensional check MFR standard Yes No No
3 Measurement of winding resistance IEC-60034-1 9.1 Yes No Yes
4 No-load test IEC-60034-2-1 6.4.2 Yes No Yes
5 Locked rotor test IEC-60034-2-1 6.4.4.4 Yes No Yes
6 Calculation of characteristics IEC-60034-2-1 8.2.2.4.3 Yes No Yes
7 Heat-run test (Temperature rise test) IEC-60034-29 6.2.4.1 Yes No Yes
8 Vibration measurement at no-load IEC-60034 14 Yes No Yes
9 Measurement of insulation resistance JEC-37 2.11 Yes No Yes
10 AC high potential test (dielectric withstanding test) IEC-60034 1 9.2 Yes No Yes
11 Noise measurement (Average, 4 key points) JEC-37 12.5 Yes * No Yes *
NOTE
1) Symbol
Yes : Applied.
No : Not Applied.
Adder : The test can be performed with extra cost, basically performed for one unit.
* : Noise will be evaluated by average of 4 key points when driven by sine wave power.
2) AC high potential test will be done by using 50Hz or 60Hz power, which depends on the location of testing facility.
Therefore applied power frequency may be different from specified frequency.
In either case, there is no difference on the stress level which affects motor insulation.
3) For determination of efficiencies Stray Loss (PLL) is considered as 0.5%.
4) Temperature rise test will be carried out based on rating HP at SF1.0.
5) Measurement of vibration will be made with portable accelerometers on bearing housing (HVA direction).
Date May.12.17
No. ADE6698-1

TMEIC STANDARD PAINTING PROCEDURE


for MODERATE CONDITION

Painting portion Surface preparation Painting

Exterior surface of rotating machine Blast cleaning(SIS-Sa2.5) ( 1 ) Prime coat


or Epoxy resin primer
Phosphate treatment 2 Coats Min. 50micron
( 2 ) Finish coat
Polyurethane enamel
1 Coat Min. 25micron

Total Min. 75micron

Interior surface of rotating machine Blast cleaning(SIS-Sa2.5) ( 1 ) Prime coat


or Epoxy resin primer
Phosphate treatment 1 Coat Min. 25micron

NOTE
TMEIC standard corrosion-proof grade 2 paint system
Machine parts purchased from sub-vendors ( Bearing oil sump surface, Bearing RTDs etc.)
will be in accordance with vendors standard.
QUOTATION No.
/ORDER No.
ADE6698

COMMENT and CLARIFICATION LIST PROJECT / PT Chandra Asri

SPECIFICATION Applied
ORIGINAL REQUIREMENTS TMEIC SPECIFICATION
PAGE CLAUSE items

Applicable standards We will apply following standards on the motor(s).


Electrical performance : IEC60034-1
Test : IEC 60034-2 Equivalent circuit, 0.5% stray loss
Dimensions : IEC60072
Explosion Proof Construction : NEC non-sparking without certificate
Materials and others : JIS ,JEC, JEM

Painting TMEIC standard corrosion-proof grade 2 paint system will be applied.


Guaranteed values at 1m under no-load and sine wave power condition (average
Limit of sound pressure level
of 4 key points) will be as shown on the specification sheet.
The motor is capable of 2 consecutive cold or 1 hot start under the load condition
Permissible maximum number of starts
stated on our specification.
Test items Tests will be carried out in accordance with the attached test items list.
Electrical performances will be calculated by equivalent circuit method in
accordance with IEC 60034-2, and 0.5% stray load loss is applied.
Temperature rise test will be carried out by superposed equivalent loading method.
Functionally duplicate will be applied. (Not identical) Only installing dimensions and
shaft diameter will be matched to existing motor. Other dimensions including cable
Replacement
conduit position will not be matched. Bearing and accessories will be current
design. Electrical performance will be as shown on the attached datasheet.
Oil relubrication interval Oil interval of self cooled sleeve bearing is approximately half a year to one year.

Oil interval of self cooled sleeve bearing is maximum two years by adopting our
Oil relubrication interval
recommendation, which is Mobil SHC626 (VG68).
All documents and name plates will be issued in English (or English and Japanese)
Language
only.
QUOTATION No.
/ORDER No.
ADE6698

COMMENT and CLARIFICATION LIST PROJECT / PT Chandra Asri

SPECIFICATION Applied
ORIGINAL REQUIREMENTS TMEIC SPECIFICATION
PAGE CLAUSE items

The machning of Reamer holes at flanged shaft at motor The existing eight (8) reamer holes at flanged shaft at shaft end was mached by
shaft end. Reamaer bolts which supplied by JSW ( Machine Vender ) ,

We will request you to the machining tools for reamer holes as below two case.
Case -1 : Please supply us the template for flanged shaft for machining of reamer
hols..

Case:2 , We will make the pilot hole at flanged shaft for site machining of reamer
holes. Please expand the reamer holes after 850kW electric motor and
Compressor & Flywheel are connected at the site.
This works is out of our scope.

Please refer to deteail of shaft end construction as existing motor.