You are on page 1of 2

®

Carboguard 193
Primer

Selection & Specification Data Substrates & Surface Preparation


Generic Type Epoxy polyamide General Surfaces must be clean and dry. Employ
adequate methods to remove dirt, dust, oil and
Description An economical, lead-free, high build maintenance- all other contaminants that could interfere with
coating primer. Cures to hard, tough film with adhesion of the coating.
excellent sub-film corrosion resistance. Has excellent
physical properties and good all-round chemical Steel Immersion : SSPC-SP10
resistance. Carboline 193 Primer has excellent Non-Immersion : SSPC-SP6
adhesion and better tolerance of field application Surface Profile : 1.5-3.0 mils (45-75 microns)
variables than other types of coatings.
Concrete Immersion: Concrete must be cured 28 days at
Features • Excellent corrosion protection. 75°F (24°C) and 50% relative humidity or
• High build film. equivalent. Prepare surfaces in accordance with
• Excellent adhesion. ASTM D4258 Surface Cleaning of Concrete and
• Very good abrasion resistance. ASTM D4259 Abrading Concrete. Voids in
• Good all-round chemical resistance. concrete may require surfacing.

Colors Red (0500), Grey (0700)

Finish Flat

Topcoat Carboguard 193 Primer may be topcoat with catalysed


epoxies vinyls, modified phenolics or others as
recommended.

Dry Film
Thickness 75 microns per coat.

Solids By Volume: 50% ± 2%


Content
Theoretical 6.67 m2/l @ 75 microns
Coverage 267 ft2/gal @ 3 mils
Rate Allow for loss while mixing and application
VOC Values As supplied : 3.00 lbs/gal (360 g/l)
Thinned:
10 oz/gal w/ #2 : 3.20 lbs/gal (387 g/l)
15 oz/gal w/ #2 : 3.40 lbs/gal (413 g/l)
16 oz/gal w/ #33 : 3.50 lbs/gal (420 g/l)
These are nominal values and may vary slightly with
color.

Dry Temp. Continuous : 2000F (930C)


0 0
Resistance Non-Continuous : 250 F (121 C)
Discoloration and loss of gloss is observed above
0 0
200 F (93 C).

Wet Temp. Immersion temperature resistance depends upon


Resistance exposure. Consult Carboline Technical Service for
specific information. It is recommended that metal
0 0
tanks operating above 140 F (60 C) be insulated.

Limitations Epoxies lose gloss, discolor and eventually chalk in


sunlight exposure.
Not recommended for splash and spillage of strong
solvents or concentrated acids.

July 2016
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact
Carboline Company to verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control.
We assume no responsibility for coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. Carboline@ and Carboguard@ are registered trademarks of Carboline Company.
®
Carboguard 193 Primer
Application Equipment Application Conditions
Conventional Pressure pot equipped with dual regulators. 3/8" I.D. Condition Material Surface Ambient Humidity
Spray minimum material hose, .070" I.D. fluid tip and appropriate 0 0 0 0 0 0
air cap. 65 -85 F 65 -85 F 65 -85 F
Normal 0 0 0 0 0 0 N/A
Airless Spray (18 -29 C) (18 -29 C) (18 -29 C)
Pump Ratio : 30:1 (min) 55 F
0
50 F
0
50 F
0

GPM Output : 3.0 (min) Minimum 0 0 0 0%


(13 C) (10 C) (10 C)
Material Hose : 3/8" I.D. (min) 0 0
Tip Size : .017-.021" 90 F
0
110 F 110 F 85%
Maximum 0 0
(43 C) 0
Output PSI : 2100-2300 (32 C) (43 C)
Filter Size : 60 mesh
This product simply requires the substrate temperature to be above the
Teflon packings are recommended and available from the
dew point. Condensation due to substrate temperatures below
pump manufacturer.
the dew point can cause flash rusting on prepared steel and interfere
with proper adhesion to the substrate. Special application techniques
Brush or Multiple coats may be required to obtain desired
may be required above or below normal application conditions.
Roller appearance, recommended dry film thickness and
(General) adequate hiding. Avoid excessive re- brushing or re-
rolling. For best results, tie in within 10 minutes at 750F
(240C).Use a medium bristle brush or a short-nap synthetic Application Conditions
roller cover with phenolic core.

Mixing & Thinning Surface Temp.


& 50% Relative Between Coats Final Cure
Mixing Power mix separately, then combine and power mix. Humidity
0 0
50 F (10 C) 24 Hours 12 Days
Ratio 1:1 Ratio (A to B)
0 0
60 F (16 C) 12 Hours 6 Days
Thinning Spray: Up to 13 oz/gal (10%) w/Carboline thinner/ #2. 0 0
Brush: Up to 19 oz/gal (15%) w/Carboline thinner #2 75 F (24 C) 6 Hours 2 Days
Roller: Up to 19 oz/gal (15%) w/Carboline thinner #2 0 0
90 F (32 C) 3 Hours 2 Days
For hot and windy conditions above 800F (240C), use
Carboline thinner no.33.
These times are based on a 75 microns dry film thickness. Higher film
Use of thinner other than those supplied or recommended by
thickness, insufficient ventilation or cooler temperatures will
Carboline may adversely affect product performance and
require longer cure times and could result in solvent entrapment and
void product warranty, whether expressed or implied.
premature failure. Excessive humidity or condensation on the surface
during curing can interfere with the cure. Can cause discoloration and
Pot Life 12 Hour at 750F (240C) Pot life ends when coating loses
may result in a surface haze. Any haze or blush must be removed by
body and begins to sag.Pot life time will be less at higher
water washing before recoating. During high humidity conditions,
temperatures.
it is recommended that the application be done while temperatures are
increasing. Maximum recoat time is 6 months without special surface
Clean Up & Safety preparation. If the maximum recoat time is exceeded, the surface must
be abraded by sweep blasting or sanding before the application
Clean Up Use Thinner #2 or Acetone. In case of spillage, absorb of additional coats.
and dispose of in accordance with local applicable
regulations.
Safety
Read and follow all caution statements on this product data Packaging, Handling & Storage
sheet and on the MSDS for this product. Employ normal
workmanlike safety precautions. Hypersensitive persons
Shipping Weight 2 Gallon kit 10 Gallon kit
should wear protective clothing, gloves and use
(Approximate) 25 lbs. (11.4 kgs) 125 lbs. (57 kgs)
protective cream on face, hands and all exposed areas.
Flash Point Carboguard 193 Primer Part A: 460F (80C)
Ventilation When used in enclosed areas and product is thinned
Carboguard 193 Primer Part B: 600F (160C)
through air circulation must be used during and after
Carboline thinner no.2: 24.80F (-40C)
application until the coating is cured. The ventilation system
Carboline thinner no.33: 1010F (380C)
should be capable of preventing the solvent vapour
concentration from reaching the lower explosion limit for the
Storage Store in cool and dry conditions.
solvents used. Users should test and monitor exposure
levels to insure all personnel are below guidelines. If not Conditions
sure or if not able to monitor levels, Use MSHA/NIOSH
Shelf Life Minimum 24 months
approved supplied air respirator.
*Shelf Life: (actual stated shelf life) when kept at recommended
Caution This product contains flammable solvents. Keep away from
sparks and open flames. All electrical equipment and
storage conditions and in original unopened containers.
installations should be made grounded in accordance with
the National Electric Code. In areas where explosion
hazards exist, workmen should be required to use non- StonCor Middle East L.L.C.
Regional Head Quarters
ferrous tools and wear conductive and non-sparking shoes.
P.O. Box 3034, Dubai, U.A.E.
Tel : 971 4 3470460
Fax : 971 4 3470242
Emaiil: info@stoncor-me.com

July 2016
To the best of our knowledge the technical data contained herein is true and accurate on the date of publication and is subject to change without prior notice. User must contact
Carboline Company to verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. We guarantee our products to conform to Carboline quality control.
We assume no responsibility for coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY CARBOLINE, EXPRESS OR IMPLIED, STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE. Carboline@ and Carboguard@ are registered trademarks of Carboline Company.