You are on page 1of 2

®

dseGenset

dse7310/20 MKII
ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
BS EN 61000-6-2
AUTO START & AUTO MAINS FAILURE EMC Generic Immunity Standard for
the Industrial Environment

CONTROL MODULES BS EN 61000-6-4


EMC Generic Emission Standard for
the Industrial Environment

ELECTRICAL SAFETY
FEATURES BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

TEMPERATURE
BS EN 60068-2-1
The DSE7310 MKII is an Auto Start The DSE7320 MKII will also monitor The extensive list of features Ab/Ae Cold Test -30 oC
Control Module and the DSE7320 the mains (utility) supply. The includes enhanced event and BS EN 60068-2-2
MKII is an Auto Mains (Utility) Failure modules include USB, RS232 and performance monitoring, remote Bb/Be Dry Heat +70 oC

Control Module suitable for a wide RS485 ports as well as dedicated communications & PLC VIBRATION
variety of single, diesel or gas, DSENet® terminals for system functionality. Dual mutual standby is BS EN 60068-2-6
Ten sweeps in each of three
gen-set applications. expansion. now available on both the DSE7310 major axes
MKII & DSE7320 MKII using RS232 5 Hz to 8 Hz at +/-7.5 mm,
Monitoring an extensive number of Both modules are compatible with or RS485 communications. This 8 Hz to 500 Hz at 2 gn

engine parameters, the modules will electronic (CAN) and non-electronic provides for a simpler and more HUMIDITY
display warnings, shutdown and (magnetic pick-up/alternator convenient installation with more BS EN 60068-2-30
Db Damp Heat Cyclic 20/55 oC
engine status information on the sensing) engines and offer an advanced features such as true at 95% RH 48 Hours
back-lit LCD screen, illuminated extensive number of flexible inputs, engine hours balancing. BS EN 60068-2-78
LEDs, remote PC and via SMS text outputs and extensive engine Cab Damp Heat Static 40 oC
at 93% RH 48 Hours
alerts (with external modem). protections so the system can be The modules can be easily
easily adapted to meet the most configured using the DSE SHOCK
BS EN 60068-2-27
demanding industry requirements. Configuration Suite PC software. Three shocks in each of three major axes
Selected front panel editing is also 15 gn in 11 mS
available. DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
MODEM MODBUS PC
DSE2130
DSE2157
DSE2548 8 6 6
DSE2510/20
232 485

®
DSENET RS232 AND USB CONFIGURABLE DC OUTPUTS ANALOGUE EMERGENCY DC POWER
EXPANSION RS485 PORT INPUTS INPUT STOP SUPPLY 8-35V

DEUTZ
DSE7310/20 MKII ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) N/C VOLT FREE GENERATOR / N/O VOLT GENERATOR CHARGE FUEL & CRANK ELECTRONIC
SENSING OUTPUT LOAD CURRENT FREE OUTPUT SENSING ALTERNATOR OUTPUTS ENGINES &
DSE7320 MKII ONLY (Flexible with CAN) MAGNETIC PICK-UP

VOLTS VOLTS
D+
W/L +

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N E/N N

ISSUE 6
®

dseGenset

dse7310/20 MKII SPECIFICATION

DC SUPPLY

AUTO START & AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING


8 V to 35 V Continuous
5 V for upto 1 minute
CONTROL MODULES CRANKING DROPOUTS
FEATURES Able to survive 0 V for 100 mS, providing
DSE7320 MKII supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
DSE7310 MKII MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V

MAXIMUM STANDBY CURRENT


330 mA at 12 V, 160 mA at 24 V

CHARGE FAIL/EXCITATION RANGE


0 V to 35 V

GENERATOR & MAINS (UTILITY)


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
KEY FEATURES • Fuel and start outputs • 3 configurable maintenance 3.5 Hz to 75 Hz
• 4-Line back-lit LCD text display configurable when using CAN alarms
• Multiple Display Languages • 6 configurable DC outputs • Compatible with a wide range MAGNETIC PICKUP
VOLTAGE RANGE
• Five key menu navigation • 2 configurable volt-free relay of CAN engines, including tier 4 +/- 0.5 V to 70 V
• LCD alarm indication outputs engine support
• Heated display option available • 6 configurable analogue/digital • Uses DSE Configuration Suite FREQUENCY RANGE
10,000 Hz (max)
• Customisable power-up text inputs PC Software for simplified
and images • Support for 0 V to 10 V & 4 mA configuration INPUTS
DIGITAL INPUTS A TO H
• DSENet expansion compatibility to 20 mA sensors • Licence-free PC software Negative switching
• Data logging facility • 8 configurable digital inputs • IP65 rating (with supplied
• Internal PLC editor • Configurable 5 stage dummy gasket) offers increased ANALOGUE INPUTS A & F
Configurable as:
• Protections disable feature load and load shedding outputs resistance to water ingress Negative switching digital input
• Fully configurable via PC using • CAN, MPU and alternator • Modules can be integrated into 0 V to 10 V sensor
USB, RS232 & RS485 frequency speed sensing in one building management systems 4 mA to 20 mA sensor
Resistive sensor
communication variant (BMS) using MODBUS RTU
• Front panel configuration with • Real time clock ANALOGUE INPUTS B, C, D & E
Configurable as:
PIN protection • Manual and automatic fuel KEY BENEFITS Negative switching digital input
• Power save mode pump control • Automatically transfers between Resistive sensor
• 3 phase generator sensing and • Engine pre-heat and post-heat mains (utility) and generator
OUTPUTS
protection functions (DSE7320 MKll only) for OUTPUT A & B (FUEL & START)
• 3 phase mains (utility) sensing • Engine run-time scheduler convenience. 15 A DC at supply voltage
and protection (DSE7320 MKII • Engine idle control for starting & • Hours counter provides accurate
OUTPUTS C & D
only) stopping information for monitoring and 8 A AC at 250 V AC (Volt-free)
• Automatic load transfer control • Fuel usage monitor and low fuel maintenance periods
(DSE7320 MKII only) level alarms • User-friendly set-up and button AUXILIARY OUTPUTS E, F, G, H, I & J
2 A DC at supply voltage
• Generator current and power • Simultaneous use of RS232 and layout for ease of use
monitoring (kW, kvar, kVA, pf) RS485 communication ports • Multiple parameters are DIMENSIONS
• Mains current and power • True dual mutual standby using monitored & displayed OVERALL
245 mm x 184 mm x 51 mm
monitoring (kW, kvar, kVA, pf) RS232 or RS485 for accurate simultaneously for full visibility 9.6” x 7.2” x 2.0”
(DSE7320 MKII only) engine hours balancing. • The module can be configured
• kW and kvar overload and • MODBUS RTU support with to suit a wide range of PANEL CUT-OUT
220 mm x 160 mm
reverse power alarms configurable MODBUS pages. applications for user flexibility 8.7” x 6.3”
• Over current protection • Advanced SMS messaging • PLC editor allows user
• Unbalanced load protection (additional external modem configurable functions to meet MAXIMUM PANEL THICKNESS
8 mm
• Independent earth fault required) user specific application 0.3”
protection • Start & stop capability via SMS requirements.
• Breaker control via fascia messaging STORAGE TEMPERATURE RANGE

-40 °F to +185 °F
buttons -40°C to +85°C

RELATED MATERIALS
OPERATING TEMPERATURE RANGE
TITLE PART NO’S
-22 °F to +158 °F
-30°C to +70°C
DSE7310 MKII & DSE7320 MKII Installation Instructions 053-181
DSE7310 MKII & DSE7320 MKII Operator Manual 057-253
-40 °C to +70 °C
HEATED DISPLAY VARIANT
DSE7310 MKII & DSE7320 MKII Configuration Suite PC Manual 057-243
-40 °F to +158 °F
DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA
Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com
Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-203/09/15 (1) US
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457