PROJECT: HOCKEY STADIUM AT HYDERABAD DOCUMENT NO. DATE
TITLE: CRACK WIDTH CALCULATION FOR WALLS DESIGNED CHECKED SHEET
PHK SSM
CHECK FOR CRACK WIDTH : as per IS 456 : 2000 ANNEX F
GRADE OF CONCRETE fck = 30 N/mm2
MOMENT AT THE SECTION CONSIDERED M = 1.5 tm
DEPTH OF THE SECTION D = 450 mm
DEPTH OF THE FLANGE Df = 150 mm
EFFECTIVE DEPTH d = 407.5 mm
BREADTH OF THE FLANGE Bf = 1000 mm
COVER TO THE COMPRESSION STEEL d' = 54.5 mm
DISTANCE FROM THE POINT CONSIDERED TO THE SURFACE OF THE NEAREST acr = 92.7 mm LONGITUDINAL BAR
MINIMUM COVER TO THE LONGITUDINAL BAR Cmin = 54.5 mm
THE WIDTH OF THE SECTION AT THE bt = 1000 mm
CENTROID OF THE TENSION STEEL
MODULAR RATIO m = Es/Ec 8
AREA OF TENSION STEEL Ast = 400 mm2
AREA OF COMPRESSION STEEL Asc = 0 mm2
NEUTRAL AXIS x = 47.97 mm
CRACKED MOMENT OF INERTIA Icr = 4.50E+08 b
SERVICE STRESS IN TENSION fs = m x M x(d-x)/Icr 93.96 N/mm2 REINFORCEMENT MODULUS OF ELASTICITY OF STEEL Es = 2.00E+05 N/mm2 DISTANCE FROM THE COMPRESSION FACE TO THE POINT AT WHICH THE CRACK WIDTH a' = 150 mm IS BEING CALCULATED STRAIN AT THE LEVEL CONSIDERED, e1 = ((D-x)/(d-x)) x fs/Es 0.000525
em = e1- (bt(d-x)(a'-x) ) 0.000405 ###
3EsAst(D-x)
DESIGN SURFACE CRACK WIDTH Wcr = 3 x acr x em 0.09 mm
Ward A. Thompson v. City of Lawrence, Kansas Ron Olin, Chief of Police Jerry Wells, District Attorney Frank Diehl, David Davis, Kevin Harmon, Mike Hall, Ray Urbanek, Jim Miller, Bob Williams, Craig Shanks, John Lewis, Jack Cross, Catherine Kelley, Dan Ward, James Haller, Dave Hubbell and Matilda Woody, Frances S. Wisdom v. City of Lawrence, Kansas Ron Olin, Chief of Police David Davis, Mike Hall, Jim Miller, Bob Williams, Craig Shanks, John L. Lewis, Jack Cross, Kevin Harmon, Catherine Kelley, Dan Ward and James Haller, Jr., 58 F.3d 1511, 10th Cir. (1995)