ALTOSONIC IV provides maximum accuracy, even under extremely harsh operating conditions.
With specially designed miniature all metal ultrasonic transducers integrated in the meter body and an
encased cabling system, the ALTOSONIC IV is an extremely robust metering system. Its compact design also
provides protection against mechanical damage, and thus ensures stable and long-term measuring
behaviour that is insensitive to interference.
Highlights
• High measurement accuracy
• Optional: solar power or battery operation
• Maintenance free, no moving parts
• Dual pulse output
• Robust design with integrated and mechanically
protected cabling system
• Extensive diagnostic functions -Accessible
through supplied user friendly software package
• Bi-directional
• Wide temperature range
• High turndown ratio
• Volume flow (actual) 8 to 12.000 m3/hr (280 to
425,000 ft3/hr)
Industries
Applications
• Natural gas industry (production, transportation,
distribution, storage)
• Gas-fired power stations
• Chemical and petrochemical industry
• Biogas plants
2 www.krohne.com
nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ALTOSONIC IV
ALTOSONIC flowmeters are the result of 30 years of experience in ultrasonic technology. They are specially
designed for custody transfer metering of hydrocarbon liquids and gasses. Advantage of ultrasonic metering:
1 ALTOSONIC V: 5-Beam custody transfer flowmeter for crude oil and oil products. The ALTOSONIC V is the only true multiproduct ul-
trasonic flowmeter in the market. The first to enter the market, it has the longest experience and the widest installed base.
Superior performance
Superior reliability
3 ALTOSONIC III: 3-Beam ultrasonic flowmeter. The economic solution for light liquid hydrocarbons.
www.krohne.com 3
ALTOSONIC IV nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
Menu-driven parameter and diagnostic software is provided with the ALTOSONIC IV. The software program
provides access to all system parameters, displays comprehensive diagnostics, and can be used as a
convenient tool for the logging of data. Self diagnostics provides reliability on whether the measurements are
within specifications.
Functions
• Logging data and parameter logs
• System diagnostics and troubleshooting
• Graphical representation of the received signal
• Customer-specific parameters
Measuring principle
ALTOSONIC IV operates just like all KROHNE ultrasonic flowmeters, by the trnasit-time differential method.
This measuring principle is based on a simple physical principle. Imagine two canoes crossing a river
diagonaaly, one with the flow and one against the flow. Naturally the canoe that is travelling with the flow will
reach the opposite side sooner that the canoe that is travelling upstream. Acoustic signals behave in a
comparable way.
By menas of ultrasonic transducers, the transit time of acoustic signals that travel upstream and
downstream are measured. The difference in transit time is proportional to the mean gas flow velocity and is
transformed into an output signal and display of volumetric gas flow rates. The 4 measuring beams are
positioned in such a way that the influence flow profile disturbance is largely reduced.
4 www.krohne.com
nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ALTOSONIC IV
Technical Data
General Data
Material flow sensor Cast steel 1.1120 / ASME A 216 WCC;
Low temperature cast steel 1.6220 / ASME A 352 LCC;
Stainless steel 1.4581 / ASME A 351 Gr. CF8M
Duplex stainless steel 1.4469 / ASME A 995 Gr. 4A
Nominal diameter DN 80, DN 100, DN 150, DN 200, DN 250, DN300, DN 400, DN 500, DN 600
3", 4", 6", 8", 10", 12", 16", 20", 24"
Maximum flow rate 400 ... 32,000 m³/h; depending on nominal diameter
Maximum flow velocity 30 ... 60 m/s, depending on nominal diameter
Pressure rating ANSI class 150, 300, 600
DIN PN 16, 64, 100
Higher pressure ratings on request
Measuring Data
Measuring data Actual volumetric flow rate, totalized volume, gas velocity, velocity of sund
Measuring accuracy Under reference conditions
Data and parameter scanning as well as limited diagnosis
Repeatability < 0.2 % of reading
Accuracy ± 0.2 % of measured value
Medium properties
Type of medium non-condensing, non-corrosive gas at -20 ... +85°C or -4 ...+185°F
process gas at -25 ... +180°C or -13...356°F
Temperature range -25 … +180°C or -13 … 356°F
Pressure range From ambient pressure to +100 bar /1480 psig
(underpressure and/or higher pressures on request)
Power supply
Operating voltage 12 ... 24 V DC
Typical power consumption <1W
Outputs
Current output 4 ... 20 mA, active/passive
Pulse and switching outputs HF pulse fmax= 6 kHz
NAMUR or open collector
insulated
Communication protocol
Modbus or HART® RS 485 for parameterization, data scanning and diagnosis or data and parameter scanning as
well as limited diagnosis
Explosion protection
Europe II 2G EEx de ib [ia] IIAT4 or IIC T4 to ATEX
ultrasonic transducers are intrinsically safe "ia"
USA / Canada Class I, Division 1, Groups B, C, D T4;
Class I, Division 2, Groups A, B, C, D T4
transducers are intrinsically safe
Special versions The following options can be delivered as special versions on request:
Versions with larger diameters
High-pressure versions for more than 250 bar
Offshore versions
www.krohne.com 5
ALTOSONIC IV nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
3“ 9" 240 77 35
4“ 12" 300 121 55
6“ 18" 450 328 108
8“ 24" 600 370 168
10“ 30" 750 704 320
12“ 36" 900 924 420
14“ 42" 1050 1430 650
16“ 48" 1200 1700 770
18“ 54" 1350 2750 1250
20“ 60" 1400 3500 1600
24“ 72" 1800 5500 2500
3“ 48 1280 33 880
4“ 64 1600 44 1100
6“ 96 2400 66 1650
8“ 128 3200 88 2200
10“ 160 4000 110 2750
6 www.krohne.com
nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn ALTOSONIC IV
www.krohne.com 7
ALTOSONIC IV nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
KROHNE Overview
• Electromagnetic flowmeters • Level measuring instruments
• Variable area flowmeters • Pressure gauges
• Mass flowmeters • Temperature measuring instruments
• Ultrasonic flowmeters • Water solutions & analysis
• Vortex flowmeters • Oil and gas turnkey solutions
• Flow controllers
Addresses:
D-47058 Duisburg
Czech Republic Fax: 00-82-2-780-1749 USA
Phone:+49 (0)2 03 305 880
Sobíšická 156 krohnekorea@krohnekorea.com KROHNE, Inc.
Fax:+49 (0)2 03 305 8888
kontakt@tablar.de www.tablar.de 63800 Brno Netherlands 7 Dearborn Road Other countries
Phone: +420 (0)545.242 627 KROHNE Nederland B.V. Peabody, MA 01960
Fax: +420 (0)545 220 093 Kerkeplaat 14 Phone: +1 (800) FLOWING KROHNE Messtechnik GmbH & Co. KG
brno@krohne.cz NL-3313 LC Dordrecht Phone: +1 (978) 535 6060 (in MA) Ludwig-Krohne-Str. 5
France Phone:+31 (0)78 630 6200 info@krohne.com D-47058 Duisburg
KROHNE S.A.S. Fax:+31 (0)78 630 6405 Phone:+49 (0)203 301 0
Service Direct: +31 (0)78 630 6222
7.02476.22.00
8 www.krohne.com