PIPE LINE HEAT LOSS CALCULATION

JOB NO. : REV.


PROJECT NAME : DATE
CLIENT : CAL'D BY
LINE NO. : CHK'D BY

1. Calculation of Pipe Line Heat Loss


1.1 Input Data
Environmental & Physical Data Pipe Line Data

Air Temperature 19 ℃ Pipe Size (inch) Length (m)


Wind Velocity 0 m/s 32 8000
Emissivity 0.8 22 730
Fluid Data 20 900
Flow Rate 1,500,000 kg/hr 16 1730
Temperature 110 ℃ 14 600
Specific Heat 1.008 Kcal/kg℃ Total Length
Insulation Data
Pipe Size (inch) 32 22 20 16 14
Insulation Thickness (mm) 74 60 60 65.8 60
Outside Diameter (inch) 37.83 26.72 24.72 21.18 18.72
Heat Transfer Coefficient 0.028 Kcal/m.hr.℃

1.2 Pipe Line Heat Loss

차 Surface Coefficient of Kcal/m2.hr.℃


0.1376 Temperature ℃ Convection Radiation
32 inch 23.68 2.380 4.034
22 inch 24.41 2.647 4.049
20 inch 24.34 2.679 4.047
16 inch 23.75 2.682 4.035
14 inch 24.08 2.797 4.042

2. Calculation of heat loss of the pipe

Heat loss per meter Heat loss of line △T


(Kcal/hr.m) (Kcal/hr) (℃)
32 inch 90.60 724,829 0.48
22 inch 77.23 56,379 0.04
20 inch 70.85 63,769 0.04
16 inch 53.93 93,295 0.06
14 inch 51.90 31,137 0.02
Total - 969,409 0.64
:
: AUG.18 '04

Length (m)
8000
730
900
1730
600
11,960 m

Kcal/m2.hr.℃
Outside Film
6.413
6.695
6.727
6.717
6.839
800A Heat Loss

Environmental & Physical Data


Air Temp. 19 C 외부온도
Wind Velocity 0 m/s 풍속
Emissivity 0.8 복사율
Fluid Data
Flow Rate 1500000 kg/hr 유량
Temperature 110 C 온도
Specific Heat 1.008 Kcal/kg.C 비열
Velocity 0.89 m/s 속력
Pipe Line Data
Pipe Size 32 inch 사이즈
Length 5000 m 길이
Insulation Data
Thickness 74 mm 두께
Outside Dia. 37.83 inch 외경
Ther. Cond. 0.02794496 Kcal/m.hr.C 열전달계수

Assumed Surface Temp. 23.68 C 외부온도


Calculated Surface Temp. 23.68 C 계산외부온도
Coefficient Of Convection 2.3796152911 Kcal/m2.hr.C 대류계수
Coefficient Of Radiation 4.0336601541 Kcal/m2.hr.C 복사열계수
Coefficient Of Outside Film 6.4132754452 Kcal/m2.hr.C

Pipe heat loss 724,829 Kcal/hr


Decrease of Temperature 0.48 C
500A Heat Loss

Environmental & Physical Data


Air Temp. 19 C
Wind Velocity 0 m/s
Emissivity 0.8
Fluid Data
Flow Rate 1500000 kg/hr
Temperature 110 C
Specific Heat 1.008 Kcal/kg.C
Velocity 1.91 m/s
Pipe Line Data
Pipe Size 22 inch
Length 730 m
Insulation Data
Thickness 60 mm
Outside Dia. 26.72 inch
Ther. Cond. 0.02794496 Kcal/m.hr.C

Assumed Surface Temp. 24.41 C


Calculated Surface Temp. 24.41 C
Coefficient Of Convection 2.646671195 Kcal/m2.hr.C
Coefficient Of Radiation 4.0487527354 Kcal/m2.hr.C
Coefficient Of Outside Film 6.6954239304 Kcal/m2.hr.C

Pipe heat loss 56,379 Kcal/hr


Decrease of Temperature 0.04 C
550A Heat Loss

Environmental & Physical Data


Air Temp. 19 C
Wind Velocity 0 m/s
Emissivity 0.8
Fluid Data
Flow Rate 1500000 kg/hr
Temperature 110 C
Specific Heat 1.008 Kcal/kg.C
Velocity 2.33 m/s
Pipe Line Data
Pipe Size 20 inch
Length 900 m
Insulation Data
Thickness 60 mm
Outside Dia. 24.72 inch
Ther. Cond. 0.02794496 Kcal/m.hr.C

Assumed Surface Temp. 24.34 C


Calculated Surface Temp. 24.34 C
Coefficient Of Convection 2.6793018496 Kcal/m2.hr.C
Coefficient Of Radiation 4.0473033445 Kcal/m2.hr.C
Coefficient Of Outside Film 6.7266051941 Kcal/m2.hr.C

Pipe heat loss 63,769 Kcal/hr


Decrease of Temperature 0.04 C
400A Heat Loss

Environmental & Physical Data


Air Temp. 19 C
Wind Velocity 0 m/s
Emissivity 0.8
Fluid Data
Flow Rate 1500000 kg/hr
Temperature 110 C
Specific Heat 1.008 Kcal/kg.C
Velocity 3.72 m/s
Pipe Line Data
Pipe Size 16 inch
Length 1730 m
Insulation Data
Thickness 65.8 mm
Outside Dia. 21.18 inch
Ther. Cond. 0.02794496 Kcal/m.hr.C

Assumed Surface Temp. 23.75 C


Calculated Surface Temp. 23.75 C
Coefficient Of Convection 2.6823886114 Kcal/m2.hr.C
Coefficient Of Radiation 4.035105232 Kcal/m2.hr.C
Coefficient Of Outside Film 6.7174938434 Kcal/m2.hr.C

Pipe heat loss 93,295 Kcal/hr


Decrease of Temperature 0.06 C
350A Heat Loss

Environmental & Physical Data


Air Temp. 19 C
Wind Velocity 0 m/s
Emissivity 0.8
Fluid Data
Flow Rate 1500000 kg/hr
Temperature 110 C
Specific Heat 1.008 Kcal/kg.C
Velocity 4.93 m/s
Pipe Line Data
Pipe Size 14 inch
Length 600 m
Insulation Data
Thickness 60 mm
Outside Dia. 18.72 inch
Ther. Cond. 0.02794496 Kcal/m.hr.C

Assumed Surface Temp. 24.08 C


Calculated Surface Temp. 24.08 C
Coefficient Of Convection 2.7967809591 Kcal/m2.hr.C
Coefficient Of Radiation 4.0419239 Kcal/m2.hr.C
Coefficient Of Outside Film 6.8387048591 Kcal/m2.hr.C

Pipe heat loss 31,137 Kcal/hr


Decrease of Temperature 0.02 C