GRUNDFOS DATA BOOKLET

S pumps, range 62
54 to 79 Hp
60 Hz ANSI
S pumps, range 62

1. Introduction 3 13. Further product documentation 44


Table of contents

Introduction 3 Grundfos GO 45
Applications 3
Main constructional features 3

2. Performance range 4
Performance range, S pumps 4
Performance range, S pumps, range 62 4

3. Identification 5
Type key 5
Pump nameplate 6
FM approval plate 6

4. Selection of product 7
Ordering a pump 7

5. Product range 8
Explosion-proof pumps 8

6. Variants 9
List of variants 9

7. Construction 10
Sectional drawings, motors 10
Sectional drawings, pumps 12
Components and material specification 15

8. Product description 16
Features 16
Operating conditions 18
Motor range 18
Explosion-proof pumps 18
Pump controllers 18
Wiring diagrams 19

9. Curve charts and technical data 20


How to read the curve charts 20
Curve conditions 21
Performance tests 21
Certificates 21
Witness test 21

10. Performance curves and technical data 22


S 62 low pressure, 4-pole 22
S 62 low pressure, 4-pole 24
S 62 medium pressure, 4-pole 26
S 62 medium pressure, 4-pole 28
S 62 high pressure, 4-pole 30
S 62 high pressure, 4 pole 32

11. Accessories 34
Accessories (for installation) 34
Other accessories 35

12. Dimensions 36
Installation on auto coupling 36
Dry, vertical installation 40
Dry, horizontal installation 42

2
S pumps, range 62
1
1. Introduction

Introduction
Introduction Applications
This data booklet deals with Grundfos heavy-duty The S pumps, range 62, are designed for applications,
sewage pumps called S pumps, range 62. such as:
• raw water intake
• wastewater treatment plants
• municipal pumping stations
• public buildings
• residential housing
• blocks of apartments
• industries
• parking garages
• underground car parks
• car wash areas
• restaurants and hotels.
The pumps are suitable for both temporary and
permanent installation. The lifting bracket fitted on the
pumps facilitates easy transportation to as well as
installation at the installation site.

Main constructional features


RrA7836

• Leak-proof connections via the Grundfos SmartSeal


gasket system.
Fig. 1 S pump, range 62 • Double mechanical shaft seal system for reliable
sealing between pumped liquid and motor.
The S pumps, range 62, are a range of free-flow
• Watertight cable entry of corrosion-resistant
channel impeller pumps specifically designed for
polyamide or cast iron for FM- approved pumps.
pumping sewage and wastewater in a wide range of
municipal, private and industrial applications. • Moisture switch for continuous monitoring of motor
housing in case liquid penetrates. (Explosion proof
The pumps are made of resistant materials, such as
pumps have two moisture switches, one below the
cast iron and stainless steel. These materials ensure a
motor top cover and the other in the stator housing
proper operation.
in the bottom of the motor.)
The pumps are fitted with motors from 54 Hp up to 79
• Self-cleaning channel impeller with long vanes
Hp (40 kW up to 52 kW). The motors are 4-pole
reducing the risk of jamming or clogging.
motors, depending on the motor size.
• SmartTrim system allowing easy adjustment of
The free passage in the pumps is 3 to 4" (80 to 100
impeller clearance and maintaining maximum pump
mm).
efficiency over pump lifetime.
The pumps are available for:
• Motor in insulation class H (356 °F (180 °C)) motor
• submerged installation on auto-coupling system in insulation class H (356 °F (180 °C)) with class F
• submerged installation, free-standing (311 °F (155 °C)) temperature rise, enclosure class
• dry-pit installation, vertical IP68 with three thermal sensors in stator windings.
• dry-pit installation, horizontal. • Seal condition monitoring via water-in-oil sensor
(optional).
• Explosion-proof motors for applications involving
high risk of explosion.
• Stainless steel versions for use in corrosive or
aggressive liquids:
Q: stainless steel impeller, cast iron pump and
motor housing.

3
2 S pumps, range 62

2. Performance range
Performance range

Performance range, S pumps


H H
[m] [ft]
300
60 Hz
80

60 200
50
150
40

30 100
80 70
20 66
60 62
58
40 54

10 50
30
8

6 20
5
15
4

3 10
8
2

TM04 6557 0610


6
100 150 200 300 400 500 800 1000 1500 2000 3000 5000 10000 15000 20000
Q [US GPM]
10 20 30 40 50 60 70 80 100 200 300 400 600 800 Q [l/s]

Performance range, S pumps, range 62


H H
[m] [ft]
250 S Pumps
70 Range 62
60 200 60 Hz
50
150
40 S1.30.A50
S1.40.A50
30 100
80
70
20
60
50
40
S2.40.A80
10
9 30
8 25
7
6 20
5
15
TM04 6608 0610

0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000
Q [US GPM]
0 50 100 150 200 250 Q [l/s]

4
S pumps, range 62
3
3. Identification

Identification
Type key
Code Example S 1 .30 .A50 .540 4 .62 H .S .320 .G .N .D .6

Pump type
S Grundfos sewage and wastewater pump

Impeller type
1 Single-channel impeller
2 Dual-channel impeller

Pump passage
Maximum solids size = Code number from type designation / 10 [inch]

Pump discharge, S-type


Nominal diameter of pump discharge port =
Code number from type designation / 10 [inch]
A50 5" (125 mm)

Output power, P2
P2 = Code number from type designation / 10 [Hp]

Number of poles
4 4-pole motor

Pump range
62 Range 62

Pressure version
H High pressure
M Medium pressure
L Low pressure

Installation
S Submersible installation without cooling jacket
C Submersible installation with cooling jacket
D Dry installation, vertical
H Dry installation, horizontal

Actual impeller diameter


[mm]

Material code for impeller, pump and motor housing


G Impeller, pump housing and motor housing Cast iron
Q Impeller Stainless steel AISI 316 (DIN W.-Nr. 1.4408)

Pump version
N Non-explosion-proof pump
Ex Explosion-proof pump

Sensor version
D S pump without built-in SM 113 module
B S pump with built in SM113
C Not in use

Frequency
6 60 Hz

Voltage code and connection


11 3 x 460 Y/D

Z Custom-built products

5
3 S pumps, range 62

Pump nameplate FM approval plate


Identification

98554196
1

2 20
3 4

TM06 1740 2714 - TM06 1738 2714


5 6
7 8
9 11
10 12
13

TM05 5094 3212


14 15
16 17
18 19

Fig. 3 Ex approval plate


Fig. 2 Pump nameplate
The approval plate gives the following details:
Pos. Description
1 Type designation FM approval symbol

2 SAP code
Permitted for locations where flammable gases or vapors
3 Serial number Class I
may be present.
4 Maximum ambient temperature [°F] Permitted for locations where flammable or combustible
5 Maximum head [ft] gases can exist under normal operating conditions or
Division 1
because of repair, breakdown or faulty operation of
6 Maximum flow [gpm] equipment.
7 Maximum installation depth Group C Permitted for specific gases or vapors of Group C and D
8 Enclosure class and D that will be present.
9 Number of phases Temperature class (T code)
T3C
10 Frequency Surface temperature max. 320 °F (160 °C)

11 Rated speed [rpm] Type FM listing code (e.g. S50X13.5/4.60)

12 Voltage/current, delta connection Production year, week and serial number (e.g. 1052/
yyww/no
123456)
13 Voltage/current, star connection
14 Power input/output FM certification and classification
15 Service factor
16 Power factor Pump Approval
17 Insulation class
Class I Division 1 Group C and D Hazardous (Classified)
18 Production code [year/week] 58-70
Locations. Temperature class T3C.
19 Net weight [lb]
20 Model

6
S pumps, range 62
4
4. Selection of product

Selection of product
Ordering a pump Custom-built variants
When ordering an S pump, range 62, you need to take The S pumps can be customized to meet individual
the following four aspects into consideration. requirements. Many pump features and options are
available for customization, e.g. explosion-proof
1. Pump
versions, various cable lengths or special materials.
2. Custom-built variation (option)
Variants can be seen in section List of variants on page
3. Accessories 9. For requirements or designs not included in the list,
4. Controller. contact Grundfos.

Pump Accessories
Use the online selection tool in Grundfos Product Depending on the installation type, you may need to
Center to find the best suited pump for your application order accessories. See section Accessories on page
or use the section Product range on page 8 and the 34 for selection of the correct accessories.
section Type key on page 5 to identify the pump that Note: Ordered accessories are not fitted from factory.
best fulfils your needs. The list below is a detailed
description of the product you get if you order the Controller
following pump:
The following controllers are available:
Pump Product no Grundfos Dedicated Controls (DC).
S1.30.A50.540.4.62H.S.320.G.N.D 97632183
• Pump as specified in the type key
• 50 ft (15 m) cable
• Paint: Black, NCS S9000-N, thickness 150 μ
• Three thermal switches (Klixon), one in each phase,
or three thermal sensors (PTC)
• One moisture switch below the motor top cover (two
moisture switches below the motor top cover on
explosion-proof versions)(Explosion proof pumps
have two moisture switches, one below the motor
top cover and the other in the stator housing in the
bottom of the motor).
• ANSI-HI centrifugal pump test 11.6:2012,
Acceptance level 3B.
See section Performance curves and technical data on
page 22 for selection of a standard pump.
Note: Product specific data for the pump can also be
seen online in Grundfos Product Center using the
product number 97632183.

7
5 S pumps, range 62

5. Product range
Product range

Explosion-proof pumps
Explosion proof range
Accessories

Cable length To be ordered separately


Pump type Pump Horizontal base
[ft (m)]
stand** Vertical base Auto-coupling
stand system*
S1.30.A50.540.4.62H.S.320.G.Ex.D 50 (15) 97660708 - - 97626242
S1.30.A50.540.4.62H.C.320.G.Ex.D 50 (15) 97660709 - - 97626242
S1.30.A50.540.4.62H.D.320.G.Ex.D 50 (15) 97660710 - 96308238 -
S1.30.A50.540.4.62H.H.320.G.Ex.D 50 (15) 97660731 96787496 - -
S1.40.A50.540.4.62M.S.292.G.Ex.D 50 (15) 97660732 - - 97626242
S1.40.A50.540.4.62M.C.292.G.Ex.D 50 (15) 97660733 - - 97626242
S1.40.A50.540.4.62M.D.292.G.Ex.D 50 (15) 97660734 - 96094523 -
S1.40.A50.540.4.62M.H.292.G.Ex.D 50 (15) 97660735 96787497 - -
S1.30.A50.700.4.62H.S.334.G.Ex.D 50 (15) 97660736 - - 97626242
S1.30.A50.700.4.62H.C.334.G.Ex.D 50 (15) 97660737 - - 97626242
S1.30.A50.700.4.62H.D.334.G.Ex.D 50 (15) 97660738 - 96308238 -
S1.30.A50.700.4.62H.H.334.G.Ex.D 50 (15) 97660739 96787496 - -
S2.40.A80.540.4.62L.S.245.G.Ex.D 50 (15) 97660740 - - 97506541
S2.40.A80.540.4.62L.C.245.G.Ex.D 50 (15) 97660741 - - 97506541
S2.40.A80.540.4.62L.D.245.G.Ex.D 50 (15) 97660742 - 96856263 -
S2.40.A80.540.4.62L.H.245.G.Ex.D 50 (15) 97660743 96857521 - -
S2.40.A80.700.4.62L.S.256.G.Ex.D 50 (15) 97660744 - - 97506541
S2.40.A80.700.4.62L.C.256.G.Ex.D 50 (15) 97660745 - - 97506541
S2.40.A80.700.4.62L.D.256.G.Ex.D 50 (15) 97660746 - 96856263 -
S2.40.A80.700.4.62L.H.256.G.Ex.D 50 (15) 97660747 96857521 - -
S1.40.A50.700.4.62M.S.308.G.Ex.D 50 (15) 97660748 - - 97626242
S1.40.A50.700.4.62M.C.308.G.Ex.D 50 (15) 97660749 - - 97626242
S1.40.A50.700.4.62M.D.308.G.Ex.D 50 (15) 97660750 - 96094523 -
S1.40.A50.700.4.62M.H.308.G.Ex.D 50 (15) 97660751 96787497 - -
S1.40.A50.790.4.62M.S.326.G.Ex.D 50 (15) 97660752 - - 97626242
S1.40.A50.790.4.62M.C.326.G.Ex.D 50 (15) 97660753 - - 97626242
S1.40.A50.790.4.62M.D.326.G.Ex.D 50 (15) 97660754 - 96094523 -
S1.40.A50.790.4.62M.H.326.G.Ex.D 50 (15) 97660755 96787497 - -
S2.40.A80.790.4.62L.S.272.G.Ex.D 50 (15) 97660756 - - 97506541
S2.40.A80.790.4.62L.C.272.G.Ex.D 50 (15) 97660757 - - 97506541
S2.40.A80.790.4.62L.D.272.G.Ex.D 50 (15) 97660758 - 96856263 -
S2.40.A80.790.4.62L.H.272.G.Ex.D 50 (15) 97660759 96857521 - -
S1.30.A50.790.4.62H.S.351.G.Ex.D 50 (15) 97660760 - - 97626242
S1.30.A50.790.4.62H.C.351.G.Ex.D 50 (15) 97660761 - - 97626242
S1.30.A50.790.4.62H.D.351.G.Ex.D 50 (15) 97660762 - 96308238 -
S1.30.A50.790.4.62H.H.351.G.Ex.D 50 (15) 97660763 96787496 - -

* Installation type S and C pumps with discharge flange size 10" (DN 250) and higher are supplied with guide claw mounted on the flange.
** The horizontal base stand is included in the pump product number.

8
S pumps, range 62
6
6. Variants

Variants
List of variants
Motor
82 ft (25 m)
Various cable lengths
165 ft (50 m)
33 ft (10 m)
50 ft (15 m)
EMC power cables Screened power cables for variable speed drives
82 ft (25 m)
165 ft (50 m)
Special motor Special voltage
PTC thermistors in windings
Special oil Non-toxic Shell Ondina X420

Motor protection
PTC + moisture switch FPV1
Klixon + moisture switch + WIO* FPV2a
PTC + moisture switch + WIO* FPV2b
Klixon + moisture switch + WIO* + Pt100 at lower and upper bearing FPV4a
PTC + moisture switch + WIO* + Pt100 at lower and upper bearing FPV4b

Materials
Stainless steel lifting bracket AISI 316
Stainless steel impeller Duplex and 316 stainless steel Variant Q
Ceramic coatings for volute and impellers Belzona 1321

Tests
Test at specified duty on standard impeller curve
Trimmed impeller for specified duty test
Additional test of entire QH curve (incl. report) 5-10 flows from pump performance curve
HI 11.6:2012 grade 2B/2U
tolerances
Different test standard Efficiency guaranteed by Grundfos
HI 11.6:2012 grade 1B/1U
tolerances
Vibration test (incl. report) According to Grundfos factory quality standard
Performance test on dry test stand Not yet available
NPSHr test Not yet available
String test Contact Grundfos
Witness test Contact Grundfos

Miscellaneous
Special packaging Contact Grundfos
Special nameplate Contact Grundfos
Other variants Contact Grundfos

* WIO sensor is standard for explosion-proof pumps. Available as accessory for non-explosion-proof pumps.

9
7 S pumps, range 62

7. Construction
Construction

Sectional drawings, motors

TM04 2308 2308

Fig. 4 Explosion-proof motor without cooling jacket

10
S pumps, range 62
7

Construction
TM04 2309 2308

Fig. 5 Explosion-proof motor with cooling jacket

11
7 S pumps, range 62

Sectional drawings, pumps


Construction

301

494

TM04 2310 2308

Fig. 6 S pump 62 frame

12
S pumps, range 62
7

Construction
702

703
701

TM04 2315 2308

Fig. 7 Installation type S and C pump on auto coupling

13
7 S pumps, range 62
Construction

TM04 2316 2308


Fig. 8 Installation type D pump

TM04 2313 2308

Fig. 9 Installation type H pump

14
S pumps, range 62
7
Components and material specification

Construction
Motor Pump
Pos. Component Material (AISI/DIN W.-Nr.) Pos. Component Material (AISI/DIN W.-Nr.)
7a Rivet Stainless steel (316/1.4436) 7a Rivet
25a Screw Stainless steel (316/1.4436) 9a Key (for keyway) Stainless steel (316/1.4436)
25 Pressure test plug Stainless steel (316/1.4436) 12c Adjusting screw Stainless steel (316/1.4436)
48 Stator lamination 26 Screw Stainless steel (316/1.4436)
55** Stator housing Cast iron (EN-JL 1040 / A48-40B) 37 O-ring NBR rubber
58 Seal housing Cast iron 37b O-ring NBR rubber
60 Bearing bracket cover Cast iron Cast Iron
49** Impeller
61c Upper bearing bracket Cast iron EN-GJL-250 (A48-40B)
72a O-ring NBR rubber Cast Iron
50 Volute casing
72 O-ring NBR rubber EN-GJL-250 (A48-40B)
76a Approval plate 67 Impeller screw Stainless steel (316/1.4436)
100 O-ring NBR rubber 76 Nameplate
105b Mechanical seal SiC/SiC or SiC/carbon 301 Motor housing
105 Mechanical seal SiC/SiC or SiC/carbon 494 Plug Stainless steel (316/1.4436)
150c Cooling jacket Galvanized steel 495 O-ring NBR rubber
153 Ball bearing Stainless steel
154 Ball bearing Stainless steel Accessories
155** Lower bearing bracket Cast iron
157b O-ring NBR rubber Pos. Component Material
157 O-ring NBR rubber Auto-coupling base
701** Cast iron
164a** Motor top cover Cast iron unit
168* Cable entry PA or cast iron 702** Guide rail bracket Cast iron
172 Shaft with rotor Stainless steel (329/1.4462) 703** Guide claw Cast iron
173b Earth terminal 731 Base stand, vertical Galvanized steel
173c Washer Stainless steel (316/1.4436) 749 Bend Cast iron
173e Screw Stainless steel (316/1.4436) 761** Hose connector Cast iron or stainless steel
173f Spring washer Stainless steel (316/1.4436) 487 Base stand, horizontal Galvanized steel
173g Earth connector 799 Anchor bolt
173 Screw Stainless steel (316/1.4436)
* Ex versions have cast iron cable entry and two moisture switches.
176a Terminal block ** Available of stainless steel (custom-built option).
176b Screw Stainless steel (316/1.4436)
176c Terminal block
176d Terminal block
178 Screw Stainless steel (316/1.4436)
180 Cable clamp PA or cast iron
181a Screw Stainless steel (316/1.4436)
181 Cable ATON
Hexagon socket head
182b Stainless steel (316/1.4436)
cap screw
184b Screw Stainless steel (316/1.4436)
184 Screw Stainless steel (316/1.4436)
187a Washer Stainless steel (316/1.4436)
187 Circlip
188 Circlip
190 Lifting bracket Galvanized steel
193 Plug Stainless steel (316/1.4436)
194 O-ring NBR rubber
197 Washer Stainless steel (316/1.4436)
198 Rubber seal
248 Screw Stainless steel (316/1.4436)
250a Cable entry PA or cast iron
250b Rubber seal
250 Cable clamp PA or cast iron
252 Cable ATON
520a Screw Stainless steel (316/1.4436)
520b Nut Stainless steel (316/1.4436)
520* Moisture switch
522 Holder

15
8 S pumps, range 62

8. Product description
Product description

Features Ball bearings


The bearings are greased for life.
SmartTrim
Main bearings: Double-row angular contact ball
On conventional pumps, maintaining factory-set bearing. Single or pair mounted angular contact ball
impeller clearance is a time-consuming and costly bearings for axial forces and cylindrical roller bearing
task. The pumps need to be disconnected from the for radial forces.
pipework and to be totally dismantled, and new parts
Support bearings: Single-row deep-groove ball
need to be mounted in order to maintain full pumping
bearing.
efficiency. Not so with Grundfos SmartTrim!
All Grundfos heavy-duty channel-impeller pumps, Shaft seal
whether for submerged or dry installation, are The pumps have a shaft seal consisting of a separate
equipped with the unique SmartTrim impeller primary and a secondary shaft seal.
clearance adjustment system. This enables you to The material combination of the primary shaft seal of
easily restore factory-set impeller clearance and all pump types is silicon carbide/silicon carbide. For
maintain peak pumping efficiency (fig. 10). All you the secondary shaft seal, the material combination is
need to do is to tighten the adjustment screws on the silicon carbide/carbon.
exterior of the impeller housing. This can be done on The shaft seals are placed in the oil chamber of the
site, quickly and easily, without dismantling the pump pump. The oil chamber provides reliable sealing
and without using special tools. between the pumped liquid and the motor.
Efficiency drop in % The shaft seals have no springs or other parts in direct
contact with the pumped liquid. This prevents rags and
0
Factory-set impeller clearance fibres from getting caught. The shaft seals are
bidirectional, meaning that they can operate in either
3 A
direction thus allowing for opposite rotation caused by
6 back-flow of liquid through the pump.
9 Motor
12
TM04 2391 2508

The motor is a watertight, totally encapsulated motor


15 B with:
• insulation class H (356 °F (180 °C))
Years
1 2 3 4 5 • temperature rise class F (189 °F (105 °K))
Fig. 10 Impeller clearance adjustment cycle • enclosure class IP68.
For motor protection and sensors, see section Sensors
A: With Grundfos SmartTrim impeller clearance below.
adjustment system
B: Without impeller clearance adjustment system
SmartSeal
For pumps with 10" (250 mm) discharge or larger, the
Grundfos SmartSeal auto-coupling gasket mounted on
the pump discharge flange provides a completely
leak-proof connection between the pump and the base
unit of the auto-coupling system. This optimizes the
efficiency of the entire pumping system and keeps
operating costs at a minimum.

16
S pumps, range 62
8
Power cables Sensors

Product description
Standard cable As standard the pump is equipped with:
• Three thermal switches (Klixon), one in each phase.
Outer cable diameter Bending
Cable type [in. (mm)] radius • One moisture switch in terminal block.in standard
[mm2] pumps. Two moisture switches in explosion-proof-
min. max. [in. (mm)]
pumps.
4x6 0.62 (15.7) 0.68 (17.2) 4.3 (110)
4 x 10 0.82 (20.9) 0.92 (23.4) 5.5 (140) Customized sensor options
4 x 16 0.94 (23.8) 1.04 (26.3) 6.3 (160) 1. WIO (water-in-oil) sensor
EMC cable The WIO sensor measures the water content in the
oil and converts the value into an analog current
Outer cable diameter Bending signal. The two sensor conductors are for power
Cable type [in. (mm)] radius
[mm2] supply as well as for carrying the signal to the
min. max. [in. (mm)] measuring device or controller. The sensor
3 x 6/6 0.54 (13.6) 0.6 (15.2) 3 (76) measures the water content from 0 to 20 %. It also
3 x 10/10 0.7 (17.8) 0.78 (19.8) 3.9 (99) sends a signal if the water content is outside the
3 x 16/16 0.82 (20.9) 0.9 (22.9) 4.53 (115) normal range (warning), or if there is air in the oil
Control cable chamber (alarm). The sensor is fitted in a stainless
steel tube for mechanical protection.The sensor is
Outer cable diameter Bending either built-in with the motor (Ex) or installed as an
Cable type [in. (mm)] radius
[mm2]
accessory. If the sensor is installed externally it is
min. max. [in. (mm)] fitted in a plastic hose for mechanical protection.
0.63 - 0.65 The WIO sensor is connected to the Grundfos IO
7 x 1.5 0.57 (14.4) 4 (100)
(16.0 - 16.4) 113 module.
10 x 1.5 0.71 (18) 0.79 (20) 4.7 (12)
2. PVS 3 (pump vibration sensor)
The cables are 50 ft (15 m) long as standard. For The vibration sensor monitors the vibration level of
18 x 1.5 cable used for full sensor model, please refer the pump by using measurements of three axes and
to factory for dimensions. Other cable lengths are combining them into a single measurement
available on request. See section List of variants on outputted in an analog current signal. The sensor
page 9. acts only as a general indicator of changes in the
The number and dimension of cables depend on the vibration levels. The PVS3 is to be connected to the
motor size. Grundfos IO 113 and SM 113 modules. A
substantial increase in vibration will trigger a
Motor power warning or an alarm.
Cable
[Hp (kW)]
An increase in vibrations can be caused by a
20 - 27 - 37 clogged impeller, worn bearings, closed force main
2 x 4 x 6 mm2 + 7 x 1.5 mm2
(15 - 20 - 28)
valves, etc. indicating that service inspection should
40 - 55 - 58
2 x 4 x 10 mm2 + 7 x 1.5 mm2 be carried out quickly in order to protect the pump
(30 - 41 - 43)
2 x 4 x 16 mm2 + 7 x 1.5 mm2 67 (50) or the pipe system from being damaged.
3. Bearing temperature sensor
Cable entry
PT 100 bearing temperature sensor installed within
Watertight PA or cast iron cable entry with soft shape the motor housing. Sensors to be connect using a
and sealing rings to prevent damage of the cable or SM 113 and IO 113.
leaks.
Testing
All pumps are tested before leaving the factory. The
factory test report is based on ANSI-HI centrifugal
pump test 11.6:2012, Acceptance level 3B. Test
reports can be ordered directly with the pump or can
be ordered separately based on the pump serial
number. See section List of variants on page 9.

17
8 S pumps, range 62

Operating conditions Explosion-proof pumps


Product description

Pumps without cooling jacket in submerged


Approval standards
installation:
These pumps are approved by FM according to
• Continuous operation when pump is fully
FM3600, FM3615 and FM3615.80.
submerged to top of motor.
• Intermittent operation with max. 20 starts per hour Explanation to FM approval
when pump is submerged to middle of motor and
with short periods of operation down to the top of The S pumps have the following explosion protection
the pump housing. classification: Class I, Division 1, Groups C and D, T4,
Note: Explosion proof pumps should be fully T3C, IP68
submerged. Standards Code Description
Pumps with cooling jacket in submerged and dry Class I
Explosive atmosphere is caused by
gas or vapors.
installation:
Division 1 Area classification
• Continuous and intermittent operation with max. 20 FM3600 Groups C
Classification of gases
starts per hour with water level down to the top of FM3615 and D
FM3615.80 Maximum surface temperature is 320
the pump housing. T3C
°F (160 °C)
Note: Explosion proof pump should be fully
Enclosure class according to IEC
submerged in a submersible application. IP68
60529

Pumped liquids
Pump controllers
pH value: 4-10
Liquid temperature: 32 °F - 104 °F (0 °C - +40 °C) S pumps, range 62, can be controlled by Grundfos
When pumping liquids with a density and/or a Dedicated Controls (DC).
kinematic viscosity higher than that of water, use The Grundfos Dedicated Controls system can control
motors with correspondingly higher outputs. from one to six pumps.
Sound pressure The Dedicated Controls system starts/stops the S
pumps by means of:
The sound pressure level of the pump is lower than the
• float switches
limiting values stated in the EC Council directive 2006/
42/EC relating to machinery (the EC Machinery • pressure sensor or
Directive). • ultrasonic sensor.
Furthermore, it is possible to control the water level by
Motor range both float switches and an analog pressure sensor or
ultrasonic sensor.
Shaft power [Hp (kW)] No. of poles Optionally, it can control a mixer and/or a flush valve.
54 (40) 4 The Dedicated Controls system can be extended with
64 (48) 4 an IO 113 module per pump (for S pumps with built-in
79 (59) 4 analog sensor).
For further settings, see the installation and operating
instructions for the pump controller selected.

18
S pumps, range 62
8
Wiring diagrams

Product description
Sensors Power cable
Thermal switch
Motor

Moisture switches

Oil indicator
(WIO)

TM06 4937 3215

TM05 1758 3611


4...20 mA

Switch board Internal wiring


Switch board Internal connection for
connection connections
connection sensors

Fig. 11 Wiring diagram for standard sensors Fig. 13 Wiring diagram for 460 volt

Sensors
Thermal switch

Thermistors

Moisture switches

Pt100 lower bearing

Pt100 stator
Pt100 upper bearing

Oil indicator
(WIO)

TM06 4954 3315


TM06 1919 3414

4...20 mA

Switch board Internal connection for


connections sensors

Fig. 12 Wiring diagrams for full sensor model Fig. 14 Wiring diagram for frame size 62

19
9 S pumps, range 62

9. Curve charts and technical data


Curve charts and technical data

The following many pages are divided into sections:


Pages 20 and 21 A brief explanation of how to read the curve charts, the curve conditions, etc.

Performance curves and technical data:


Page 22 Low pressure
Page 26 Medium pressure
Page 30 High pressure

How to read the curve charts


Total pump head Max. efficiency mark Pump type
H = Htotal
62: Range 62
M: Pressure range (Medium pressure)
S: Installation type

+ +
>P@ >IW@
  06
6
$
 
 +]
6
$ +,%
 
 

 QH curve for the individual


 pump


 
136+

>IW@

 

 6$ 

NPSH curve for all variants
 6$  shown. When sizing the pumps,
   add a safety margin of at least
1.6 ft (0.5 m)
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

  The power curves indicate shaft

TM04 6583 1914


 power [P2] for the pumps shown




          4>86*30@

Note: The pumps are tested according to ANSI HI 11.6:2012 grade 3B tolerance. Testing equipment and measuring
instruments are designed and calibrated according to the standards mentioned. The pumps are approved according to
tolerances for entire curves, specified in grade 3B.

20
S pumps, range 62
9
Curve conditions Performance tests

Curve charts and technical data


The guidelines below apply to the curves shown in the The requested duty point for every pump is tested
performance charts on page 22 to page 32. according to Hi 11.6:2012, grade 3B, and without
• ANSI-HI centrifugal pump test 11.6:2012, certification.
Acceptance level 3B. In case of pumps ordered on the basis of impeller
• The curves show pump performance with different diameter only (no requested duty point), the pump will
impeller diameters at rated speed. be tested close to the best efficiency point (BEP) of the
• The bold part of the curves show the published performance curve which is related to the
recommended operating range. ordered impeller diameter (according to HI 11.6:2012,
grade 3B).
• The curves apply to the pumping of airless water at
a temperature of 68 °F (+20 °C) and a kinematic If the customer requires either more points on the
viscosity of 1 cSt (1 mm2/s). curve to be checked or certain minimum performances
or certificates, individual measurements must be
• NPSH: The curves show average values measured
made, and a certificate can be ordered.
under the same conditions as the performance
curves.
When dimensioning the pump, add a safety margin Certificates
of at least 1.6 ft (0.5 m).
Certificates have to be confirmed for every order and
• In case of other densities than 133.5 ounces/gallon are available on request as follows:
(1000 kg/m3), the discharge pressure is proportional
• Certificate of compliance with the order (EN 10204 -
to the density.
2.1)
• When pumping liquids with a density higher than
• Pump test sheet.
133.5 ounces/gallon (1000 kg/m3), motors with
correspondingly higher outputs must be used.
Calculation of total head
Witness test
The total pump head consists of the height difference When the pumps are being tested or are tested with a
between the measuring points + the differential head + certification it is possible for the customer to witness
the dynamic head. the testing procedure according to HI 11.6:2012.
The witness test is not a certificate and will not result in
a written statement from Grundfos. The witness itself is
H total = H geo + Hstat + Hdyn
the only guarantee that everything is carried out as
prescribed in the testing procedure.
Hgeo: Height difference between measuring points. If the customer wants to witness test the pump
Hstat: Differential head between suction and the performance, place this request on the order.
discharge side of the pump.
Hdyn: Calculated values based on the velocity of the
pumped liquid on the suction and the discharge
side of the pump.

21
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

10. Performance curves and technical data


S 62 low pressure, 4-pole
S2.40.A80.540 and S2.40.A80.700
+ +
>P@ >IW@
/6

6
$
+]

 +,%

  136+
6
$
 >IW@

  


 

 6$ 
 6$

 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 


 6$

 

TM04 6581 1914


6$





          4>86*30@

+ +
>P@ >IW@

6
 $


+&'+
6
   $

+]

 +,%
 




136+
  >IW@
 

 

 6$ 
 6$
 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

 
TM04 6580 1914






          4>86*30@

22
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight*
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
57.9 37.8 14.0 26.0 25.4 9.4 8" 1411
S2.40.A80.540.4.62L.S. S - 97632195
(1471) (960) (356) (660) (646) (240) (DN 200) (640)
57.9 37.8 14.0 26.0 25.4 9.4 8" 1543
S2.40.A80.540.4.62L.C C - 97632196
(1471) (960) (356) (660) (646) (240) (DN 200) (700)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1698
S2.40.A80.540.4.62L.D D 97632197
(1491) (960) (356) (660) (646) (263) (DN 200) (DN 200) (770)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1698
S2.40.A80.540.4.62L.H H 97632198
(1491) (960) (356) (660) (646) (263) (DN 200) (DN 200) (770)
57.9 37.8 14.0 26.0 25.4 9.4 8" 1411
S2.40.A80.700.4.62L.S S - 97632199
(1471) (960) (356) (660) (646) (240) (DN 200) (640)
57.9 37.8 14.0 26.0 25.4 9.4 8" 1543
S2.40.A80.700.4.62L.C C - 97632200
(1471) (960) (356) (660) (646) (240) (DN 200) (700)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1698
S2.40.A80.700.4.62L.D D 97632201
(1491) (960) (356) (660) (646) (263) (DN 200) (DN 200) (770)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1698
S2.40.A80.700.4.62L.H H 97632202
(1491) (960) (356) (660) (646) (263) (DN 200) (DN 200) (770)

* With 50 ft (15 m) cable

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of Breakdown
No. of Starting
Pump type RPM inertia torque Mmax
poles method
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)] [lbf*ft (Nm)]
59 54 7.12 438.8
S2.40.A80.540.4.62L 4 1770 Y/D 73 571 87 89 90 0.60 0.70 0.77
(44) (40) (0.3) (595)
71 64 7.12 438.8
S2.40.A80.700.4.62L 4 1764 Y/D 85 571 88 90 90 0.65 0.75 0.79
(53) (64) (0.3) (595)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S2.40.A80.540.4.62L.S. 9.6 (245) 4 (100) 145 (10) 66 (20)
S2.40.A80.540.4.62L.C 9.6 (245) 4 (100) 145 (10) 66 (20)
S2.40.A80.540.4.62L.D 9.6 (245) 4 (100) 145 (10) 66 (20)
S2.40.A80.540.4.62L.H 9.6 (245) 4 (100) 145 (10) 66 (20)
S2.40.A80.700.4.62L.S 10.0 (256) 4 (100) 145 (10) 66 (20)
S2.40.A80.700.4.62L.C 10.0 (256) 4 (100) 145 (10) 66 (20)
S2.40.A80.700.4.62L.D 10.0 (256) 4 (100) 145 (10) 66 (20)
S2.40.A80.700.4.62L.H 10.0 (256) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

23
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

S 62 low pressure, 4-pole


S2.40.A80.790
H H
[m] [ft]
S2.40.A80.790.4. 62L.S
120
60 Hz
HI 11.6:2012 3B
30 100 NPSH
[ft]
80 40

20
S2.40.A80.790.4.
60 30

40 20
10

20 10

0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 50 100 150 200 250 300 Q [l/s]


P2 P2
[kW] [hp]
60 80
S2.40.A80.790.4.

50 70

60
40

TM04 6838 1914


50

30 40

30
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

H H
[m] [ft]
S2.40.A80.790.4. 62L.C/D/H
120
60 Hz
HI 11.6:2012 3B
30 100 NPSH
[ft]
80 40

20 S2.40.A80.790.4.
60 30

40 20
10

20 10

0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

0 50 100 150 200 250 300 Q [l/s]


P2 P2
[kW] [hp]
60 80 S2.40.A80.790.4.

50 70

60
40
TM04 6922 1914

50

30 40

30
0 500 1000 1500 2000 2500 3000 3500 4000 4500 Q [US GPM]

24
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight*
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
57.9 37.8 14.0 26.0 25.4 9.4 8" 1455
S2.40.A80.790.4.62L.S S - 97632211
(1471) (960) (356) (660) (646) (240) (DN 200) (660)
57.9 37.8 14.0 26.0 25.4 9.4 8" 1609
S2.40.A80.790.4.62L.C C - 97632212
(1471) (960) (356) (660) (646) (240) (DN 200) (730)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1742
S2.40.A80.790.4.62L.D D 97632213
(1494) (960) (356) (660) (646) (263) (DN 200) (DN 200) (790)
58.8 37.8 14.0 26.0 25.4 10.3 8" 8" 1742
S2.40.A80.790.4.62L.H H 97632214
(1494) (960) (356) (660) (646) (263) (DN 200) (DN 200) (790)

* With 50 ft (15 m) cable

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of
No. of Starting Breakdown torque
Pump type RPM inertia
poles method Mmax [lbf*ft (Nm)]
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)]
88 79
S2.40.A80.790.4.62L 4 1768 Y/D 105 527 88 90 90 0.61 0.72 0.79 9.0 (0.38) 476.5 (646)
(66) (59)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S2.40.A80.790.4.62L.S 10.7 (272) 4 (100) 145 (10) 66 (20)
S2.40.A80.790.4.62L.C 10.7 (272) 4 (100) 145 (10) 66 (20)
S2.40.A80.790.4.62L.D 10.7 (272) 4 (100) 145 (10) 66 (20)
S2.40.A80.790.4.62L.H 10.7 (272) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

25
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

S 62 medium pressure, 4-pole


S1.40.A50.540 and S1.40.A50.700
+ +
>P@ >IW@
  06
6
$
 
 +]
6
$ +,%
 
 





 
136+

>IW@

 

 6$ 

 6$ 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

 

TM04 6583 1914







          4>86*30@

+ +
>P@ >IW@
 
6
0&'+
$
 
 +]
6$ +,%
 
 





 
136+

>IW@

 

 6$ 

 6$ 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

 
TM04 6584 1914






          4>86*30@

26
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight*
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
57.6 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.540.4.62M.S S - 1323 (600) 97632187
(1463) (690) (276) (440) (552) (245) (DN 125)
57.6 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.540.4.62M.C C - 1455 (660) 97632188
(1463) (690) (276) (440) (552) (245) (DN 125)
57.8 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.540.4.62M.D D 1587 (720) 97632189
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)
57.8 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.540.4.62M.H H 1698 (770) 97632190
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)
57.6 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.700.4.62M.S S - 1323 (600) 97632203
(1463) (690) (276) (440) (552) (245) (DN 125)
57.6 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.700.4.62M.C C - 1455 (660) 97632204
(1463) (690) (276) (440) (552) (245) (DN 125)
57.8 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.700.4.62M.D H 1587 (720) 97632205
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)
57.8 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.700.4.62M.H D 1587 (720) 97632206
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)

* With 50 ft (15 m) cable

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of
No. of Starting Breakdown torque
Pump type RPM inertia
poles method Mmax [lbf*ft (Nm)]
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)]
59 54
S1.40.A50.540.4.62M 4 1770 Y/D 73 571 87 89 90 0.60 0.70 0.77 7.12 (0.3) 438.8 (595)
(44) (40)
71 64
S1.40.A50.700.4.62M 4 1764 Y/D 85 571 88 90 90 0.65 0.75 0.79 7.12 (0.3) 438.8 (595)
(53) (48)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S1.40.A50.540.4.62M.S 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.540.4.62M.C 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.540.4.62M.D 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.540.4.62M.H 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.700.4.62M.S 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.700.4.62M.C 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.700.4.62M.D 11.5 (292) 4 (100) 145 (10) 66 (20)
S1.40.A50.700.4.62M.H 11.5 (292) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

27
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

S 62 medium pressure, 4-pole


S1.40.A50.790
+ +
>P@ >IW@

6$
06
  +]
 +,%

 




136+
  >IW@
 
 6$
 

 

 

  
            4>86*30@

         4>OV@


3 3
>N:@ >KS@
 
6$

 




TM04 6837 1914




 


            4>86*30@

H H
[m] [ft]
220
S1.40.A50.790.4.
62M.C/D/H
60 200 60 Hz
180 HI 11.6:2012 3B
50 160

140
40
120
NPSH
30 100 [ft]
80 40
20 S1.40.A50.790.4.
60 30

40 20
10
20 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

0 20 40 60 80 100 120 140 160 Q [l/s]


P2 P2
[kW] [hp]
60 80
S1.40.A50.790.4.

50 70

60
40
TM04 6921 1914

50

30 40

30
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 Q [US GPM]

28
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight*
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
57.8 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.790.4.62M.S S - 1367 (620) 97632207
(1463) (690) (276) (440) (552) (245) (DN 125)
57.8 27.1 10.8 17.3 21.7 9.6 5"
S1.40.A50.790.4.62M.C C - 1499 (680) 97632208
(1463) (690) (276) (440) (552) (245) (DN 125)
57.7 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.790.4.62M.D H 1631 (740) 97632209
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)
57.7 27.1 10.8 17.3 21.7 9.8 8" 5"
S1.40.A50.790.4.62M.H D 1631 (740) 97632210
(1467) (690) (276) (440) (552) (249) (DN 200) (DN 125)

* With 50 ft (15 m) cable

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of Breakdown
No. of Starting
Pump type RPM inertia torque Mmax
poles method
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)] [lbf*ft (Nm)]
88 79
S1.40.A50.790.4.62M 4 1768 Y/D 105 527 88 90 90 0.61 0.72 0.79 9 (0.38) 476.5 (646)
(66) (59)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S1.40.A50.790.4.62M.S 12.8 (326) 4 (100) 145 (10) 66 (20)
S1.40.A50.790.4.62M.C 12.8 (326) 4 (100) 145 (10) 66 (20)
S1.40.A50.790.4.62M.D 12.8 (326) 4 (100) 145 (10) 66 (20)
S1.40.A50.790.4.62M.H 12.8 (326) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

29
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

S 62 high pressure, 4-pole


S1.30.A50.540 and S1.30.A50.700

+ +
>P@ >IW@
 6
$

+6

  +]
 6
$
+,%

  





136+
  >IW@
 

 

 6$ 
 6$
 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

 

TM04 6579 1914







          4>86*30@

+ +
>P@ >IW@

6
 $


+&'+
6
   $

+]

 +,%

 




136+
  >IW@
 

 

 6$ 
 6$
 

  
          4>86*30@

       4>OV@


3 3
>N:@ >KS@
 
6$

 6$

 
TM04 6580 1914






          4>86*30@

30
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight*
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
56.5 27.1 10.2 17.3 20.6 9.0 5"
S1.30.A50.540.4.62H.S S - 1323 (600) 97632183
(1435) (690) (260) (440) (523) (230) (DN 125)
56.5 27.1 10.2 17.3 20.6 9.0 5"
S1.30.A50.540.4.62H.C C - 1455 (660) 97632184
(1435) (690) (260) (440) (523) (230) (DN 125)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5"
S1.30.A50.540.4.62H.D H 1587 (720) 97632185
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5"
S1.30.A50.540.4.62H.H D 1698 (770) 97632186
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125)
56.5 27.1 10.2 17.3 20.6 9.0 5"
S1.30.A50.700.4.62H.S S - 1323 (600) 97632191
(1435) (690) (260) (440) (523) (230) (DN 125)
56.5 27.1 10.2 17.3 20.6 9.0 5"
S1.30.A50.700.4.62H.C C - 1455 (660) 97632192
(1435) (690) (260) (440) (523) (230) (DN 125)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5"
S1.30.A50.700.4.62H.D H 1587 (720) 97632193
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5"
S1.30.A50.700.4.62H.H D 1587 (720) 97632194
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125)

* With 50 ft (15 m) cable

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of Breakdown
No. of Starting
Pump type RPM inertia torque Mmax
poles method
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)] [lbf*ft (Nm)]
59 54
S1.30.A50.540.4.62H. 4 1770 Y/D 73 571 87 89 90 0.60 0.70 0.77 7.12 (0.3) 438.8 (595)
(44) (40)
71 65
S1.30.A50.700.4.62H 4 1764 Y/D 85 571 88 90 90 0.65 0.75 0.79 7.12 (0.3) 438.8 (595)
(53) (48)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S1.30.A50.540.4.62H.S 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.540.4.62H.C 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.540.4.62H.D 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.540.4.62H.H 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.700.4.62H.S 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.700.4.62H.C 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.700.4.62H.D 12.6 (320) 4 (100) 145 (10) 66 (20)
S1.30.A50.700.4.62H.H 12.6 (320) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

31
10 Performance curves and technical data S pumps, range 62
Performance curves and technical data

S 62 high pressure, 4 pole


S1.30.A50.790
H H
[m] [ft]
S1.30.A50.790.4.
62H.S
240
60 Hz
HI 11.6:2012 3B
60 200 NPSH
[ft]
160 40

40
120 S1.30.A50.790.4. 30

80 20
20

40 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 20 40 60 80 100 120 Q [l/s]


P2 P2
[kW] [hp]
60 80
S1.30.A50.790.4.

50 70

60
40

TM04 6839 1914


50

30 40

30
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

H H
[m] [ft]
S1.30.A50.790.4.
62H.C/D/H
240
60 Hz
HI 11.6:2012 3B
60 200 NPSH
[ft]
160 40

40
120 S1.30.A50.790.4. 30

80 20
20

40 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

0 20 40 60 80 100 120 Q [l/s]


P2 P2
[kW] [hp]
60 80 S1.30.A50.790.4.

50 70

60
40
TM04 6923 1914

50

30 40

30
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]

32
S pumps, range 62 Performance curves and technical data
10

Performance curves and technical data


Product range and dimensions
Installation Weight
Pump type A C D E F H DN1 DN2 Product number
type [lb (kg)]
56.5 27.1 10.2 17.3 20.6 9.0 5" 1367
S1.30.A50.790.4.62H.S S - 97632215
(1435) (690) (260) (440) (523) (230) (DN 125) (620)
56.5 27.1 10.2 17.3 20.6 9.0 5" 1499
S1.30.A50.790.4.62H.C C - 97632216
(1435) (690) (260) (440) (523) (230) (DN 125) (680)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5" 1631
S1.30.A50.790.4.62H.D H 97632217
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125) (740)
58.1 27.1 10.2 17.3 20.6 10.7 6" 5" 1631
S1.30.A50.790.4.62H.H D 97632218
(1477) (690) (260) (440) (523) (272) (DN 150) (DN 125) (740)

Electrical data
P1 P2 IN Istart ηmotor [%] Cos φ Moment of Breakdown
No. of Starting
Pump type RPM inertia torque Mmax
poles method
[Hp (kW)] [A] [A] 1/2 3/4 1/1 1/2 3/4 1/1 [lbft2 (kgm2)] [lbf*ft (Nm)]
S1.30.A50.790.4.62H 66 79 4 1768 Y/D 105 527 88 90 90 0.61 0.72 0.79 9 (0.38) 529.5 (718)

Note: Enclosure class: IP68

Pump data
Impeller diameter Max. solids size Pump housing pressure Max. installation depth
Pump type
[in. (mm)] [in. (mm)] [PSI (PN)] [ft (m)]
S1.30.A50.790.4.62H.S 13.8 (351) 4 (100) 145 (10) 66 (20)
S1.30.A50.790.4.62H.C 13.8 (351) 4 (100) 145 (10) 66 (20)
S1.30.A50.790.4.62H.D 13.8 (351) 4 (100) 145 (10) 66 (20)
S1.30.A50.790.4.62H.H 13.8 (351) 4 (100) 145 (10) 66 (20)

Dimensional sketches
Size DN PSI (PN) Dc Dt D∅
A40 145 7.1 0.78
8 x 18
(DN 100) (10) (180) (20)
A50 145 8.3 0.86
8 x 18
(DN 125) (10) (210) (22)
A60 145 9.5 0.86
8 x 22
(DN 150) (10) (240) (22)
A80 145 11.6 0.94
8 x 22
(DN 200) (10) (295) (24)
A100 145 13.8 1.02
12 x 22
(DN 250) (10) (350) (26)
TM04 2411 2508

33
11 S pumps, range 62

11. Accessories
Accessories

Accessories (for installation)


Pump type Installation accessories
S 50-70 S and C NPS 3-8 (DN 80-200) without guide claw (guide claw included in auto-coupling kit)
S 50-70 S and C NPS 10-24 (DN 250-600) with guide claw mounted on the pump
S 50-70 D Pump without installation accessories (accessories as separate kit)
S 50-70 H Base stand for horizontal, dry installation supplied together with the pump

Weight Product
Pictures Description Size PN
[kg] number

Discharge flange
Cast-iron, epoxy-coated auto-coupling system NPS 8" (DN 200) 551 (250) 10 97506541
complete with:
• guide claw*
• base unit
• upper guide rail bracket NPS 5"/NPS 6" 229.28
Gr8126

• gaskets and bolts. 10 97626242


(DN 125/150) (104)

NPS 5"/NPS 6"


3 96829331
(DN 125/150)
Intermediate guide rail bracket For guide rails longer than 19.5 ft (6 m)
NPS 8"/NPS 24"
8 96255842
(DN 200/DN 600)

Guide rails Standard pipes. Not supplied by Grundfos

NPS 6" (DN150) 96308238


Suction flange

Vertical base stand (without bend) NPS 8" (DN 200) 96094523
TM04 4035 0509

NPS 10" (DN 250) 96856263

* Installation type S and C pumps with discharge flange size NPS 10" (DN 250) and higher are supplied with guide claw mounted on the flange.

34
S pumps, range 62
11
Other accessories

Accessories
Product
Pictures Description Dimensions
number

13 ft (4 m) galvanized lifting chain with lifting link and safety hook.


96468294
With certificates.

20 ft (6 m) galvanized lifting chain with lifting link and safety hook.


96468295
With certificates.

26 ft (8 m) galvanized lifting chain with lifting link and safety hook. 7054.8 lb
S 62-72 96468296
With certificates. (3200 kg)

33 ft (10 m) galvanized lifting chain with lifting link and safety hook.
96468297
With certificates.

40 ft (12 m) galvanized lifting chain with lifting link and safety hook.
96468298
With certificates.

13 ft (4 m) stainless steel lifting chain with lifting link and safety hook.
96490259
With certificates.

20 ft (6 m) stainless steel lifting chain with lifting link and safety hook.
96490270
With certificates.

26 ft (8 m) stainless steel lifting chain with lifting link and safety hook. 7054.8 lb
S 62-72 96490271
With certificates. (3200 kg)
TM02 6126 5102

33 ft (10 m) stainless steel lifting chain with lifting link and safety hook.
96490272
With certificates.

40 ft (12 m) stainless steel lifting chain with lifting link and safety hook.
96490273
With certificates.

35
12 S pumps, range 62

12. Dimensions
Dimensions

Installation on auto coupling

Min level
Installation S

Min level
Installation C

TM05 1662 3411


Fig. 15 Dimensional sketches, installation on auto-coupling system

Note: Z12a is minimum recommended distance from pit bottom to bottom of pump suction side.
Note: Z11 is total height of pump installed on Grundfos installation accessory in the pit.
This figure might not equal Z12a + Z1.

36
S pumps, range 62
12

Dimensions
Pump type C F Z01 Z1 Z2 Z3 Z4 Z6 Z7 Z8 Z9 Z10 Z11
in. 27.1 20.6 56.5 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.2
S1.30.A50.540.4.62H 8 x 23
(mm) (690) (523) (1435) (300) (123) (280) (1261) (947) (697) (110) (88) (1605)
in. 27.1 20.6 56.5 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.2
S1.30.A50.700.4.62H 8 x 23
(mm) (690) (523) (1435) (300) (123) (280) (1261) (947) (697) (110) (88) (1605)
in. 27.1 20.6 56.5 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.2
S1.30.A50.790.4.62H 8 x 23
(mm) (690) (523) (1435) (300) (123) (280) (1261) (947) (697) (110) (88) (1605)
in. 27.1 20.6 57.6 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.7
S1.40.A50.540.4.62M 8 x 23
(mm) (690) (523) (1463) (300) (123) (280) (1261) (947) (697) (110) (88) (1618)
in. 27.1 20.6 57.6 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.7
S1.40.A50.700.4.62M 8 x 23
(mm) (690) (523) (1463) (300) (123) (280) (1261) (947) (697) (110) (88) (1618)
in. 27.1 20.6 57.6 11.8 4.8 11.0 49.6 37.3 27.4 4.3 3.5 63.7
S1.40.A50.790.4.62M 8 x 23
(mm) (690) (523) (1463) (300) (123) (280) (1261) (947) (697) (110) (88) (1618)

Z17
Pump type Z12a Z12b Z13 Z14 Z15 Z16 ZDc1 ZDN1 ZDt1 ZL1 ZL2 ZM
G S
in. 3.1 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.30.A50.540.4.62H 0 0 4 x M16
(mm) (80) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)
in. 3.1 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.30.A50.700.4.62H 0 0 4 x M16
(mm) (80) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)
in. 3.1 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.30.A50.790.4.62H 0 0 4 x M16
(mm) (80) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)
in. 3.9 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.40.A50.540.4.62M 0 0 4 x M16
(mm) (100) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)
in. 3.9 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.40.A50.700.4.62M 0 0 4 x M16
(mm) (100) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)
in. 3.9 15.7 11.0 22.6 0.1 0.1 9.4 6" 1.0 22.5 5.8
S1.40.A50.790.4.62M 0 0 4 x M16
(mm) (100) (400) (280) (575) (3.0) (3.0) (240) (DN 150) (25) (571) (147)

37
12 S pumps, range 62
Dimensions

Min level
Installation S

Min level
Installation C

TM05 1667 3411


Fig. 16 Dimensional sketches, installation on auto-coupling system

Note: Z12a is minimum recommended distance from pit bottom to bottom of pump suction side.
Note: Z11 is total height of pump installed on Grundfos installation accessory in the pit.
This figure might not equal Z12a + Z1.

38
S pumps, range 62
12

Dimensions
Pump type C F Z01 Z1 Z2 Z3 Z4 Z6 Z7 Z8 Z9 Z10 Z11
in. 37.8 25.4 57.9 16.9 7.9 21.1 67.8 53.2 41.4 6.7 3.5 64.0
S2.40.A80.540.4.62L 8 x 23
(mm) (960) (646) (1471) (430) (200) (535) (1721) (1352) (1052) (170) (88) (1627)
in. 37.8 25.4 57.9 16.9 7.9 21.1 67.8 53.2 41.4 6.7 3.5 64.0
S2.40.A80.700.4.62L 8 x 23
(mm) (960) (646) (1471) (430) (200) (535) (1721) (1352) (1052) (170) (88) (1627)
in. 37.8 25.4 57.9 16.9 7.9 21.1 67.8 53.2 41.4 6.7 3.5 64.0
S2.40.A80.790.4.62L 8 x 23
(mm) (960) (646) (1471) (430) (200) (535) (1721) (1352) (1052) (170) (88) (1627)

Z17
Pump type Z12a Z12b Z13 Z14 Z15 Z16 ZDc1 ZDN1 ZDt1 ZL1 ZL2 ZM
G S
in. 6.1 7.7 7.9 3.4 14.4 19.0 0.1 0.1 11.6 8" 1.2 30.0 8.7
S2.40.A80.540.4.62L 4 x M24
(mm) (156) (196) (200) (86) (365) (485) (3.0) (3.0) (295) (DN 200) (31) (761) (222)
in. 6.1 7.7 7.9 3.4 14.4 19.0 0.1 0.1 11.6 8" 1.2 30.0 8.7
S2.40.A80.700.4.62L 4 x M24
(mm) (156) (196) (200) (86) (365) (485) (3.0) (3.0) (295) (DN 200) (31) (761) (222)
in. 6.1 7.7 7.9 3.4 14.4 19.0 0.1 0.1 11.6 8" 1.2 30.0 8.7
S2.40.A80.790.4.62L 4 x M24
(mm) (156) (196) (200) (86) (365) (485) (3.0) (3.0) (295) (DN 200) (31) (761) (222)

39
12 S pumps, range 62

Dry, vertical installation


Dimensions

TM05 1658 3411


Fig. 17 Dimensional sketch, dry, vertical installation

40
S pumps, range 62
12

Dimensions
Pump type C F X03 X05 X4 X5 X6 X10 X13 X131 X132 X14 X15
in. 27.1 20.6 0.9 0.9 11.8 11.6 24.4 6" 17.7 5.9 4.7 11.4 20.5
S1.30.A50.540.4.62H.H
(mm) (690) (523) (24) (24) (300) (296) (621) (DN 150) (450) (150) (120) (290) (520)
in. 27.1 20.6 0.9 0.9 11.8 11.6 24.4 6" 17.7 5.9 4.7 11.4 20.5
S1.30.A50.700.4.62H.H
(mm) (690) (523) (24) (24) (300) (296) (621) (DN 150) (450) (150) (120) (290) (520)
in. 27.1 20.6 0.9 0.9 11.8 11.6 24.4 6" 17.7 5.9 4.7 11.4 20.5
S1.30.A50.790.4.62H.H
(mm) (690) (523) (24) (24) (300) (296) (621) (DN 150) (450) (150) (120) (290) (520)
in. 27.1 21.7 0.9 0.9 13.8 13.5 28.3 8" 20.7 6.9 4.7 10.4 23.9
S1.40.A50.540.4.62M.H
(mm) (690) (552) (24) (24) (350) (344) (719) (DN 200) (525) (175) (120) (265) (606)
in. 27.1 21.7 0.9 0.9 13.8 13.5 28.3 8" 20.7 6.9 4.7 10.4 23.9
S1.40.A50.700.4.62M.H
(mm) (690) (552) (24) (24) (350) (344) (719) (DN 200) (525) (175) (120) (265) (606)
in. 27.1 21.7 0.9 0.9 13.8 13.5 28.3 8" 20.7 6.9 4.7 10.4 23.9
S1.40.A50.790.4.62M.H
(mm) (690) (552) (24) (24) (350) (344) (719) (DN 200) (525) (175) (120) (265) (606)
in. 37.8 25.4 0.9 1.1 15.7 16.7 33.7 8" 23.6 7.9 5.9 18.1 27.2
S2.40.A80.540.4.62L.H
(mm) (960) (646) (24) (28) (400) (425) (857) (DN 200) (600) (200) (150) (460) (692)
in. 37.8 25.4 0.9 1.1 15.7 16.7 33.7 8" 23.6 7.9 5.9 18.1 27.2
S2.40.A80.700.4.62L.H
(mm) (960) (646) (24) (28) (400) (425) (857) (DN 200) (600) (200) (150) (460) (692)
in. 37.8 25.4 0.9 1.1 15.7 16.7 33.7 8" 23.6 7.9 5.9 18.1 27.2
S2.40.A80.790.4.62L.H
(mm) (960) (646) (24) (28) (400) (425) (857) (DN 200) (600) (200) (150) (460) (692)

Pump type X16 X17 XDc3 XDt1 Dt2 XM1


in. 82.6 35.1 9.4 0.9 0.9
S1.30.A50.540.4.62H.H M20 x 6
(mm) (2098) (893) (240) (24) (24)
in. 82.6 35.1 9.4 0.9 0.9
S1.30.A50.700.4.62H.H M20 x 6
(mm) (2098) (893) (240) (24) (24)
in. 82.6 35.1 9.4 0.9 0.9
S1.30.A50.790.4.62H.H M20 x 6
(mm) (2098) (893) (240) (24) (24)
in. 86.0 38.1 11.6 1.0 1.0
S1.40.A50.540.4.62M.H M20 x 6
(mm) (2186) (968) (295) (26) (26)
in. 86.0 38.1 11.6 1.0 1.0
S1.40.A50.700.4.62M.H M20 x 6
(mm) (2186) (968) (295) (26) (26)
in. 86.0 38.1 11.6 1.0 1.0
S1.40.A50.790.4.62M.H M20 x 6
(mm) (2186) (968) (295) (26) (26)
in. 92.6 44.1 14.2 1.1 1.1
S2.40.A80.540.4.62L.H M20 x 6
(mm) (2351) (1120) (362) (28) (28)
in. 92.6 44.1 14.2 1.1 1.1
S2.40.A80.700.4.62L.H M20 x 6
(mm) (2351) (1120) (362) (28) (28)
in. 92.6 44.1 14.2 1.1 1.1
S2.40.A80.790.4.62L.H M20 x 6
(mm) (2351) (1120) (362) (28) (28)

41
12 S pumps, range 62

Dry, horizontal installation


Dimensions

TM05 1660 3411


Fig. 18 Dimensional sketch, dry, horisontal installation

42
S pumps, range 62
12

Dimensions
Pump type D F Q03 Q1 Q2 Q3 Q4 Q5 Q6 Q8 Q10 QDc1 DN1
in. 10.2 20.6 0.71 58.9 11.4 32.1 14.7 4.5 19.7 15.4 32.1 9.4 6"
S1.30.A50.540.4.62H.H
(mm) (260) (523) (18) (1495) (290) (815) (375) (115) (500) (390) (815) (240) (DN 150)
in. 10.2 20.6 0.71 58.9 11.4 32.1 14.7 4.5 19.7 15.4 32.1 9.4 6"
S1.30.A50.700.4.62H.H
(mm) (260) (523) (18) (1495) (290) (815) (375) (115) (500) (390) (815) (240) (DN 150)
in. 10.2 20.6 0.71 58.9 11.4 32.1 14.7 4.5 19.7 15.4 32.1 9.4 6"
S1.30.A50.790.4.62H.H
(mm) (260) (523) (18) (1495) (290) (815) (375) (115) (500) (390) (815) (240) (DN 150)
in. 10.9 20.5 0.71 58.5 10.5 32.1 14.7 4.5 19.7 15.4 32.1 11.7 8"
S1.40.A50.540.4.62M.H
(mm) (276) (522) (18) (1485) (267) (815) (375) (115) (500) (390) (815) (298) (DN 200)
in. 10.9 20.5 0.71 58.5 10.5 32.1 14.7 4.5 19.7 15.4 32.1 11.7 8"
S1.40.A50.700.4.62M.H
(mm) (276) (522) (18) (1485) (267) (815) (375) (115) (500) (390) (815) (298) (DN 200)
in. 10.9 20.5 0.71 58.5 10.5 32.1 14.7 4.5 19.7 15.4 32.1 11.7 8"
S1.40.A50.790.4.62M.H
(mm) (276) (522) (18) (1485) (267) (815) (375) (115) (500) (390) (815) (298) (DN 200)
in. 14.0 25.4 0.75 59.5 11.1 47.6 21.7 4.5 19.7 15.4 34.1 14.3 8"
S2.40.A80.540.4.62L.H
(mm) (356) (646) (19) (1512) (281) (1210) (550) (115) (500) (390) (865) (362) (DN 200)
in. 14.0 25.4 0.75 59.5 11.1 47.6 21.7 4.5 19.7 15.4 34.1 14.3 8"
S2.40.A80.700.4.62L.H
(mm) (356) (646) (19) (1512) (281) (1210) (550) (115) (500) (390) (865) (362) (DN 200)
in. 14.0 25.4 0.75 59.5 11.1 47.6 21.7 4.5 19.7 15.4 34.1 14.3 8"
S2.40.A80.790.4.62L.H
(mm) (356) (646) (19) (1512) (281) (1210) (550) (115) (500) (390) (865) (362) (DN 200)

Pump type D1N Q01 QZ1 DN2 D2N D02 QDc2 Dt2
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.30.A50.540.4.62H.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.30.A50.700.4.62H.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.30.A50.790.4.62H.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.40.A50.540.4.62M.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.40.A50.700.4.62M.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 8" 0.71 5" 8 0.9 8.5 0.9
S1.40.A50.790.4.62M.H M20
(mm) (DN 200) (18) (DN 125) (203) (22.9) (216) (22.9)
in. 12" 0.71 8" 8 0.9 11.7 1
S2.40.A80.540.4.62L.H M20
(mm) (DN 300) (18) (DN 200) (203) (22.9) (297) (25.4)
in. 12" 0.71 8" 8 0.9 11.7 1
S2.40.A80.700.4.62L.H M20
(mm) (DN 300) (18) (DN 200) (203) (22.9) (297) (25.4)
in. 12" 0.71 8" 8 0.9 11.7 1
S2.40.A80.790.4.62L.H M20
(mm) (DN 300) (18) (DN 200) (203) (22.9) (297) (25.4)

43
13 S pumps, range 62

13. Further product documentation


Further product documentation

Grundfos Product Center is an online


search and sizing tool to help you make
the right choice.

http://product-selection.grundfos.com

SIZING enables you to REPLACEMENT enables you to find a


size a pump based on replacement product.
entered data and Search results will include information on
selection choices.
• the lowest purchase price
• the lowest energy consumption
• the lowest total life cycle cost.

CATALOG gives you LIQUIDS enables you to find pumps


access to the Grundfos designed for aggressive, flammable
product catalog. or other special liquids.

All the information you need in one place Downloads


Performance curves, technical specifications, pictures, dimensional drawings, motor On the product pages, you can download
curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. installation and Operating Instructions, data
The Product Center displays any recent and saved items - including complete projects - booklets, service instructions, etc. in PDF format.
right on the main page.

44
S pumps, range 62
13
Grundfos GO

Further product documentation


Mobile solution for professionals on the GO!
Grundfos GO is the mobile tool box for professional users on the go. It is the most comprehensive platform for mobile
pump control and pump selection including sizing, replacement and documentation. It offers intuitive, handheld
assistance and access to Grundfos online tools, and it saves valuable time for reporting and data collection.

GET IT ON

Subject to alterations.

45
© Copyright Grundfos Holding A/S
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
97682350 1015
ECM: 1164157

GRUNDFOS Chicago
3905 Enterprise Court
P.O. Box 6620
Aurora, IL 60598-0620
Phone: +1-630-236-5500
Fax: +1-630-236-5511

GRUNDFOS Kansas City


17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Fax: +1-913-227-3500
www.grundfos.us

GRUNDFOS Canada
2941 Brighton Road
Oakville, Ontario L6H 6C9 Canada
Phone: +1-905 829 9533
Fax: +1-905 829 9512
www.grundfos.ca

GRUNDFOS México
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
C.P. 66600 Apodaca, N.L Mexico
Phone: +011-52-81-8144 4000
Fax: +011-52-81-8144 4010
www.grundfos.mx