NOTE ON THE SEAL QUALIFICATION TEST AND COOLER TEST FOR

KOCHI - COIMBATORE - ERODE - SALEM - LPG PIPELINE PROJECT


EIL ENQ. NO. : A538-020-PA-MR-5010-REV.A
Rev 1 21/4/2014
ITEM NOS. 20-PA-CF-101 AB & 30-PA-CF-101 AB

NOTE ON THE SEAL QUALIFICATION TEST


1 Engineered seals are required for above items as per Clause no. 15 of Spec. No. A-538-020-16-45-PA-SP-5010-REV.A.
1.1 Seals will be sourced from our Principal Eagle Burgmann, Japan in cartridge construction.
Seals will be suitable for stuffing box pressure during operation considering maximum suction pressure and for a maximum
1.2
allowable working pressure of the pump in static condition.
1.3 Test Fluid Selection & Application Group will be as per Table 7 of API 682. Propane/LPG will be used as a test fluid.
1.4 Test parameters as well as base points conditions will be as per Fig. 29 - Propane Test Parameter of API 682.
1.5 SQT will be carried out as per Fig. 33 of API 682 but in the condensed form of 4+4+1 hrs.
1.6 Pressure Cyclic Test will be carried out. However, Temperature Cyclic Test is not applicable.
For testing of the Seals for MAWP in static condition, water will be used as a media as Propane/LPG cannot be used for such
1.7 high pressure during the test.
1.8 The Propane Testing will be carried out at Eagle Burgmann, Japan.
Propane Testing in Japan can be offered only in the months of November, December & January. The Pump OEMs are
1.9 requested to make a note of this point for delivery of the mechanical seals.
1.10 Only 1 no. seal for each item will be tested for the above referred SQT.

1.11 2 nos coolers are must for Plan 53C. Temp. Rise to be restricted to 10 Degc over ambient temp. Site ambient temp. to be
created while testing the cooler as per Job spec Rev c
NOTE ON THE COOLER TESTING
1 Forced Draft Coolers will be used for Plan-53C.
1.1 2 nos coolers are must for each Plan 53C
1.2 Cooler Testing will be carried out independent of the Seal Qualification Test.
1.3 Plan-53C will not be used for the Cooler Performance Test.
2 nos coolers are must for Plan 53C. Temp. Rise to be restricted to 10 Degc over ambient temp. Site ambient temp. to be
1.4
created while testing the cooler as per Job spec Rev c
Deviation From the  specifications  ‐ Seals and Seal systems
1 Junction Box / wiring Cable  not in EBIPL scope of supply specified any where in any specification. It is in Oem scope of supply if at all required.

The Requirement is Plan 53C. Spec calls for Guided wave Radar . In plan 53C ‐ Piston movement is to  measure for Seal failure / Leakage. Guided wave radar can not be used.  We have offered special  
magnetic Level Gauge cum Level Transmitter as manufactured by  Piston accumulator Manufacturer.  Therefore Neither Make of Level Gauge or Level Transmitter  will be as per EIL  approved make. This 
2 combine equipment / Instrument will be as per Piston accumulator manufacturer`s standard only. Approved vendor list not applicable.  CCOE  certificate will be provided for Level Transmitter.
3 Level Transmitter to be Mounted in External Chamber. Please refer  explaination above. Level transmitter as offered is part of Piston accumulator assembly only. Can not be seperated out.

Rev 1 No. of coolers  and Cooler test Prameters defined as per Revised Job specification. All changes highlighted like this.