Theoretical coverage per US gallon : 31.2 m² at the Drying times between coats :
recommended dry film thickness. For application of subsequent coat, the minimum and
Important: Spreading rates are calculated on volume solids and do maximum drying times between coats must be followed as
not include an application loss factor due to surface profile, recommended.
roughness or porosity of the surface, skill and technique of the Temperature Minimum Maximum
applicator, method of application, various surface irregularities, 61ºF 12 hours Ilimited
material lost during mixing, spillage, overthinning, climatic
conditions, and excessive film build.
77°F 8 hours Ilimited
90°F 4 hours Ilimited
Metallic zinc in dry film : 84% ± 2 If exposed to weathering for long time periods, wash the
surface with water and soap to remove dirt, oil or grease,
white corrosion or other contamination form surface, before
Total zinc in dry film : 87 % ± 2
coating. Do not use sandpaper.
Pot life : 4 hours at 77ºF.
Note : Higher temperatures reduce the pot life.
Dry heat resistance :
Maximum temperature of 932ºF (500ºC).
Shelf Life : Part A 12 months
Part B 12 months
Storage conditions : Keep the material in closed cans and
protected from weathering at temperature not higher than
104ºF (40ºC).
Equipment clean up :
Use WATER