You are on page 1of 1

DR.

FIXIT PIDICRETE CF LF
High Range Water reducing and retarding admixture for concrete

CONCRETE ADMIXTURES
Dr. Fixit Pidicrete CF LF is a superplasticising admixture to COMPATIBILITY:
produce pumpable or flowable concrete, free from bleeding Dr. Fixit Pidicrete CF LF is compatible with all types of
and segregation when added to the concrete mix having cement e.g. OPC, PPC, PSC etc.
slump atleast 20 mm without admixture.
Dr. Fixit Pidicrete CF LF is compatible with all air
It also imparts the cohesiveness to concrete mix for easy entraining agent which complies wiith IS 9103-2003
placing and pumping. and Integral water proofing compound which
SPECIFICATION: IS: 9103-1999 and ASTM-C-494-86, Type G complies with IS 2645- 1978. If other admixtures are
to be used in concrete containing Dr. Fixit Pidicrete
CF LF, they must be dispensed separately.
AREA OF APPLICATION:
Structural Concrete
STORAGE :
Ready mix concrete
Keep the liquid above freezing temperature.
Pavement Concrete
If the product has frozen, thaw it at room temperature
(25°C) and agitate until complete reconstitute in the
FEATURES & BENEFITS: original form.
Water reduction upto 20% without effecting the workability Store under cover, protect from direct sunlight.
Helps in reducing cement content for a required strength Failure to comply with recommended storage
by reducing w/c ratio. condition may result in premature deterioration of the
Increases workability at a given w/c ratio, resulting easy product and packaging.
placing, and eliminates honeycomb.
High workability for longer periods to allow long distance DOSAGE:
transport of concrete.
Dosage range of Dr. Fixit Pidicrete CF LF will be 250 ml
Reduction in shrinkage cracks to 750 ml per bag of cement. Optimum dosage should
High early and ultimate compressive strength of concrete be determined by doing site trial mixes. Dosage may go
above maximum limit for High Performance Concrete
Less permeable and hence more durable
and shall be determined by site trial mix.

METHOD OF APPLICATION:
TECHNICAL INFORMATION :

PIDICRETE CF LF
Concrete shall be mixed with 50-70% of the mixing water
Appearance : Dark Brown Liquid
(based on mix design by weight).
Sp.Gravity : 1.18 ± 0.02 at 30°C
The correct quantity of Dr. Fixit Pidicrete CF LF should be
measured with recommended dispenser and should be Chloride content : Nil
added to the concrete with remaining 30% mixing water pH Value : 6±1
and allow to mix it for recommended mixing time.
Dr. Fixit Pidicrete CF LF should not be added in dry mixes
PACKING: 225 litres
under any circumstances
CC-DF-PIDI CF LF-FLR-ENG-01/06

PRECAUTION :
Dr. Fixit Pidicrete CF LF is a non-toxic and inflammable. When
in contact with the skin, it should be washed with cold water.

Disclaimer:
The product information & application details given by the company & its agents has been
Pidilite Industries Ltd. : Construction Chemicals Division. provided in good faith & meant to serve only as a general guideline during usage. Users are
advised to carry out tests & take trials to ensure on the suitability of products meeting their
Ramkrishna Mandir Road P.O.Box No.17411, Andheri (East) MUMBAI-400 059. requirement prior to full scale usage of our products. Since the correct identification of the
problems, quality of other materials used and on-site workmanship are factors beyond our
Phone : 2834 7550 Extn. 7617, 7546, 7537 • Fax : (022) 2836 7459. control, there are no expressed or implied guarantee / warranty as to the results obtained. The
• E-mail : drfixit@pidilite.com • Website : www.doctor-fixit.com Company does not assume any liability or any consequential damage for unsatisfactory results,