The SKF Multilog On-line System IMx-M is • Simultaneous measurement of all input
the latest addition to the current generation channels
of powerful, cost effective solutions suitable • Redundant Modbus RTU communications
for a variety of machinery monitoring appli- • Buffered outputs front and rear
cations. Together with SKF @ptitude Moni- • Local status indication and display
toring Suite software, the SKF Multilog • Flexible voting logic
IMx-M can provide a complete system for • Customizable filters
initiation of machinery shutdown, early fault
detection, and diagnosis. In addition, the
SKF Multilog IMx-M system can provide Machine condition monitoring
automated advice for correcting existing or • Independent of machine protection
impending conditions which can affect • DC to 40 kHz frequency range
machine reliability, availability and perform- • Overall level and vector processing
ance. • Spectrum with up to 6 400 line resolution
• Transient and steady-state data capture

Key features • Multi-parameter gating


• SKF Acceleration Enveloping – an SKF
technique used to detect impact based
Machine protection defects
• 19 inch rack format • Adaptive alarm levels
• Design based on API 670 requirements • Data buffering in non-volatile memory
• Up to 64 analog inputs (dynamic and • Fully supported by SKF @ptitude Moni-
static) per rack toring Suite
• Up to 32 digital / speed inputs per rack • Pre and Post event data capture
• Up to 96 relay outputs per rack • Exception based data storage; Independ-
• Multiple transducer types ent Normal and Alarm storage rates, store
• Radial vibration, position, temperature data when the parameter value changes
• TSI measurements (absolute shaft vibra- by more than a pre-defined amount
tion, eccentricity, and complementary dif-
ferential expansion)
SKF Multilog IMx-M system overview – front view

10

4 2

7
8
1 1 3 3 3

10
5 5 5 5

1 Power supplies, 90 to 240 V AC 6 LED Indication


Single or dual redundant. Each power supply alone may power a Each channel provides LED color for status alarms – Alert, Danger
fully loaded rack. and Transducer OK. Module OK indication.

2 Machine Protection module 7 Front buffered outputs


Supports multiple transducer types and performs signal process- Three BNC connectors on Machine Protection input / output
ing for alarm generation. module front provide direct access to buffered transducer signals.
16 dynamic channels and eight digital inputs. Segregation of Channel assignment using keypad on Condition Monitoring mod-
input channel processing such that any single circuit failure can- ule. Ideal for use with portable data analyzers (two channels +
not affect more than two channels. phase).

3 Relay module 8 USB ports


32 electro-mechanical relays with configurable logic assigned to For direct configuration of Condition Monitoring module and
any channel in the 19 inch rack, LEDs indicators and relay status. Machine Protection module pair.

4 Condition Monitoring module 9 Local user interface


Parallel data-acquisition of dynamic data for machinery analysis Condition Monitoring module provides channel value and alarm
and diagnostics independent of protection function. Also provides status bargraph display for any two channels, selectable by the
user interface and TCP/IP communications. keypad. Communications and System OK indication LEDs.

5 16 channel Condition Monitoring module and Machine 10 Custom label holder


Protection module pair All handles top and bottom, can be used for optional custom
Consisting of 16 channel Machine Protection module and 16 labelling. Simply slide out the plastic cover to insert your own
channel Condition Monitoring module. Up to four pairs per 19 customized label(s). This drastically simplifies the installation and
inch rack. Configuration shown is maximum – 64 channels with identification labelling of the system in the field.
96 relays.

2
SKF Multilog IMx-M system overview – rear view

13 5

11 11

12 5

10 10
14

5 4
6
8
7
9
1 1 1 1 2 2 2 3

1 Condition Monitoring module and Machine Protection module 9 Disarm


pairs, input and output connectors Activation by contact closure
Maximum four pairs per rack
10 Digital field inputs
2 Relay module connectors Sensor types include, but not limited to:
Maximum three modules per rack
• Eddy current probes (phase reference and speed)
3 Power supply and ground connections • TTL inputs for speed
Maximum two power supply modules per rack • Logical inputs

4 Redundant AC power feeds 11 Analog field inputs


Sensor types include, but not limited to:
5 Relay outputs
For machine protection • Eddy current probes (radial vibration, position)
• Accelerometers and velocity sensors
6 Status relays • Temperature RTD (Pt 100)
For circuit fault and disarm indication • Process variables (4 to 20 mA)
• DC voltage
7 Ethernet connections to condition monitoring with internal
switch 12 4 to 20 mA outputs
For convenient interconnection of CPU modules with external 16 recorder outputs, assignable to monitored channel variables
network. Each CPU module has an individual TCP/IP address. (one output per channel)

8 Redundant RS 485 communications 13 Rear analog buffered outputs


Two separate RS 485 lines (L1, L2) provide redundant connec- For connection to external multi-channel data analyzers
tions to DCS. No single protection module failure or removal will
affect DCS communications with other modules. 14 Digital buffered outputs
Re-transmission of tachometer signal to other systems

3
System modules, components and Certifications
technical data • CE conformity according to EN 61000-6-4:2007,
EN 61000-6-2:2005, EN/IEC 61010-1:2010,
• CMON 2007 19 inch rack with backplane and power supply con- EN/IEC 61010-1:2001
nections († page 4) • ETL certified according to UL 61010-1 2nd Edition,
• CMON 2102 Machine Protection module († page 6) CAN/CSA-22.2 no. 61010-1 2nd Edition
• CMON 2103 Machine Protection and Condition Monitoring mod- • IEC 61010-1: 2010
ule pair, input / output connector board († page 8) • IEC 61010-1: 2001
• CMON 2118 Condition Monitoring module († pages 6 and 8) • CAN/CSA 22.2, no. 61010-1, 2nd Edition
• CMON 2109 Relay module († page 10) • UL 61010-1, 2nd Edition
• CMON 2119 Relay module, input / output connector board • AS 61010-1: 2003
(† page 10)
• CMON 2202 Power Supply module († page 11)
Specific design requirements
• Designed to comply with API 670

CMON 2007
19 inch rack with backplane (including power supply connectors)

Key features one module pair, cannot influence another • Redundant power bus to Machine Protec-
• Standard 19 inch rack mounted module pair. All modules are inserted from tion and Condition Monitoring modules,
• Standard 6U height the front side of the rack. On the rack rear, total eight per rack (4 pairs)
• Robust aluminium design there are termination boards for each mod-
ule set. Physical
The 19 inch rack enclosure contains the • 19 inch rack mounted, 6U high
electronics of the SKF Multilog IMx-M. • Dimensions:
Each rack holds up to four Machine Pro- Technical data –– Height: 266 mm (10.47 in.)
tection and Condition Monitoring module –– Width: 482 mm (18.98 in.)
pairs, three relay cards and up to two Backplane –– Depth: 240 mm (9.45 in.)
redundant power supplies. The rack has a • Two slots for power supplies • Weight (bare rack): 3,5 kg (123 oz.)
backplane providing electric interconnection • Four, two slot pairs (one Machine Protec-
between Condition Monitoring and Machine tion and one Condition Monitoring mod- Environmental
Protection module pairs, relay cards and ule, always mounted in pairs) • Temperature range: –20 to +65 °C
power supplies. All module pairs are 100% • Three slots for relay cards (–4 to +149 °F)
isolated from one another so that failure of • Screw terminals, RJ45 and D-sub con- • Humidity: 95% relative humidity (non-
nectors on rear of unit condensing)

4
CMON 2007 Rack dimensions

27,8 mm 27,8 mm
(1.1 in.) 426,7 mm (1.1 in.)
(16.8 in.)

265,9 mm
(10.5 in.)

190,5 mm
(7.5 in.)

435,8 mm
(17.2 in.)

213 mm
(8.4 in.)

14 mm
(0.6 in.) 213 mm
(8.4 in.)

5
CMON 2102
Machine Protection module

Key features Technical data


• Design based on API 670 requirements
• Multiple transducer types Physical
• RTD temperature (Pt 100) • 19 inch rack mounted
• Radial vibration, position, temperature • Size: 6U high, 4TE wide
• TSI functions (absolute shaft vibration, • Weight: 0,5 kg (18 oz.)
eccentricity, complementary differential
expansion) Environmental
• Simultaneous measurement of all chan- • Temperature range: –20 to +65 °C
nels (–4 to +149 °F)
• Redundant Modbus RTU communications • Humidity: 95% relative humidity (non-
• Buffered outputs front and rear condensing)
• Local status Indication and display
• Flexible voting logic Analog inputs
• Programmable filters • 16 analog differential inputs (8 can be
• 4 to 20 mA outputs used for RTD’s)
• 90 dB dynamic range, 100 dB crosstalk • Individual ±24 V (23.5 to 28 V) power
rejection supply, maximum 30 mA/channel
• Power supply for standard accelerometers
The CMON 2102 Machine Protection mod- (8 mA constant current) for each channel
ule accepts a variety of sensor inputs. Sig- • Input range: ±23 V
nals such as vibration, acceleration, velocity • Impedance: >100 kΩ
and displacement or other parameters are • Amplitude accuracy: Typically better than
easily adopted. Each input can be configured ±1% of full scale
for standard accelerometers, velocity sen- –– Velocity input:
sors, proximity probes, 4 to 20 mA or ±23 V. ·· 0 to 1.0 IPS ±2% of full scale
All channels are processed in parallel. ·· 0 to 2.0 IPS ±1% of full scale
In addition to the analog channels, eight ·· Specified at +25 °C (+77 °F)
digital channels may be used for measuring –– Filters ±0,5 dB in passband
speed or switch input (digital) status. • Other inputs (V DC/mA)
The design prevents a single circuit failure –– V DC: –24 to +24V
from affecting more than two measurement –– mA: 4 to 20
channels. Circuit faults are indicated via NOTE: (±2% of a full scale range of 10 V)
LEDs, digital communications interface
(Modbus protocol) and relay. All channel Digital inputs
pairs are independent, and can be config- • 8 digital Opto isolated inputs with individ-
ured for redundancy. Each channel has indi- ual ±24 V (23.5 to 28 V) power supply,
cators for alarm / shutdown and it is possi- maximum 30 mA/channel (TTL two-wire
ble to manually bypass alarm and shutdown tachometers, three-wire tachometers,
(alert / danger) functionality. The system pulse, etc.). CMON 2102 CMON 2118
provides remote reset of latching alarm / • Eddy current probes supported on 4 digi-
shutdown conditions. tal inputs (–24 V DC supply)

Outputs
• 16 rear analog buffered outputs, cutoff • Dual digital communications link
frequency (–3 dB) at 60 kHz –– Alarm status, channel value, OK limits,
• 8 rear digital buffered outputs alarm setpoints, diagnostics, trip multi-
• Two analog buffered outputs at front ply status, channel enabled / disabled,
(user selectable output channel) slot enabled / disabled
• One digital buffered output at front (user
selectable output channel)
• Single 4 to 20 mA output per analog
channel

6
Processing kW, MW, %, mH, T, °, kg/cm2, cmHg, um, ·· User defined filters (1 Hz steps from
• Radial shaft vibration (Overall: displace- mm, g, mm/s, mils, ips) 1 Hz to 2400, 4800 Hz)
ment) • TSI functions (absolute shaft vibration, –– Roll-off rate: 24 dB/oct
• GAP / Bias eccentricity (direct) and complementary • Digital / Speed processing
• Casing vibration (velocity, acceleration) differential expansion) –– Peak Speed
• Absolute shaft vibration • Piston rod drop (average / triggered)
• Position • Filters: Interface
• RPM: 0,1 Hz to 7,5 kHz (eddy current –– Programmable selections • USB service interface
probe minimum >2 Hz / 120 rpm, GAP ·· 5 to 1 000 Hz, 10 to 1 000 Hz, 1 to • RS 485, Modbus, redundant, bi-direc-
dependent) 600 Hz, 4 to 4 000 Hz, 10 to 5 000 tional
• Detection: true Peak to Peak, true Zero to Hz, 1 to 10 000 Hz, displacement,
Peak (“true Peak to Peak” / 2), true RMS velocity and acceleration Other
• Temperature (°C, °F) ·· 10 to 5 000 Hz and 1 000 to • Local storage of minimum 1 400 events
• Static parameters (psi, bar, mbar, hPa, Pa, 10 000 Hz, acceleration and velocity, per Machine Protection module
MPa, kPA, mA, A, mV, V, kV, kVA, C, F, W, single channel on a paired channel
group and no integration

CMON 2102 Machine Protection CMON 2118 Machine Protection and


module (front view) Condition Monitoring module pair, input /
output connector board (rear view)

Analog
buffered
Module outputs
status LED

Analog transducer Analog


inputs transducer
inputs

Channel
status LED 4 to 20 mA
outputs

Redundant
RS 485 LEDs

USB port for


configuration of Digital inputs Digital inputs
protection part

Analog buffered
outputs
Redundant
RS 485
(protection) Status relays

Digital buffered Disarm


output Digital buffered
outputs

7
CMON 2103
Condition Monitoring module

Key features – machine Technical data


condition monitoring
Physical
• Independent of machine protection • 19 inch rack mounted
• DC to 40 kHz frequency range • Size: 6U high, 8TE wide
• Overall level and vector processing • Weight: 0,6 kg (21 oz.)
• FFT up to 6 400 line resolution
• Transient and steady-state data capture Environmental
• Multi-parameter gating • Temperature range: –20 to +65 °C
• SKF Acceleration Enveloping (–4 to +149 °F)
• Adaptive alarm levels • Humidity: 95% relative humidity (non-
• Data buffering in nonvolatile memory condensing)
• Fully supported by SKF @ptitude Moni-
toring Suite Analog measurement
• Pre and Post event data capture • 24-bit AD conversion, no gain or AC/DC
• Exception based data storage; independ- switching necessary
ent Normal and Alarm storage rates, • True simultaneous sampling of all 16
store data when the parameter value channels (no multiplexing)
changes by more than a pre-defined • Simultaneous sampling of different chan-
amount nels with different sampling rates
• Shaft center line • Frequency range: From DC to 40 kHz
• Up to 2x static/sec and 1 dynamic/sec in • Dynamic range: 120 dB
transient mode • Signal to noise ratio: 90 dB
• Full Spectrum • Cross-talk rejection: 100 dB
• Up to 10 bands / measurement • Amplitude accuracy (typical):
–– ±2% (up to 10 kHz)
The Condition Monitoring module for the –– ±5% (10 to 20 kHz)
SKF Multilog IMx-M offers data acquisition –– ±10% (up till 30 kHz)
for condition monitoring purposes, and is • Phase accuracy: ±3° (up to 100 Hz)
independent of the machinery protection • SKF Acceleration Enveloping (1 to 4), cus-
function. It acquires and processes data tom band demodulation and DPE demod-
from all channels simultaneously and in ulation (4 bands)
parallel. This allows for multiple advanced • Advanced gear analyses
signal analysis methods to be employed.
Several measurement points can be con- Digital measurement CMON 2103 CMON 2118
nected to each channel signal and individual • Frequency range: 0.1 Hz to 7.5 kHz
conditions for warning and alarm may be –– Required pulse width: >25 µs for elec-
set for each point. These conditions can be trical positive, >67 µs for electrical
based on fixed frequencies and / or speed- negative
following frequencies (including harmonics). • Accuracy, frequency: 0.05% of measure- • Window function: Hanning and Uniform
For each measurement point, multiple con- ment value (typically 0.01% up to 2.5 kHz) • Mathematical expressions
ditions can be applied – such as warning • Pulse counting • Multi-parameter gated sampling (control
and alarm levels may be controlled by by speed and / or secondary input)
machine speed or load. A built-in hardware Signal processing – condition monitoring • Dynamic alarm levels, active range deter-
diagnostic system continuously checks all • Time waveform mined on multiple parameters
sensors, cabling and electronics for any • Vector analysis with circular alarms • Data storage on time, event or alarm
faults, signal interruption, shortcuts or pow- • FFT: 100 to 6 400 lines condition
er failure. Any malfunction can be set to • SKF Acceleration Enveloping and DPE • Data buffering in flash memory when
trigger an alert alarm. In the case of system • Integration / differentiation in frequency communication link is down
power failure, the system will automatically domain • Detection of sensor and cable fault
restart when the power returns. • Averaging (spectra, CTA and TSA) • Watchdog and self testing

8
Protection LCD and keypad Interface On-board data storage (typical, per
• Set-up menu • Ethernet: 10/100 Mbit RJ45, TCP/IP module)
• Bargraph • Built-in two port data switch, 10/100 • 1 400 latest events
• Buffered output front selection Base-T • 13 000 vibration trend values
• Channel values • USB service interface • 1 000 spectra (400 lines)

CMON 2103 Condition CMON 2118 Condition Monitoring


Monitoring module (front and Machine Protection module
view) pair, input / output connector board
(rear view)

Module status LED

Local display:
• Bargraph
• Buffered output
front selection
• Channel values

Local display
selection keypad

Ethernet
connection
status LEDs

USB port for


condition
monitoring
configuration
Ethernet
connections

9
CMON 2109
Relay module

Key features – machine CMON 2109 CMON 2119 Relay input /


protection Relay module output connector module
(front view) (rear view)
• 32 relays per module (28 SPDT, 4 DPDT)
• Up to three modules per rack
• Software configurable
• Flexible relay assignment
• On board voting logic
Module
• Voting across protection input / output status
modules LED
• Redundant operation
• Normally open / normally closed
• Normally energized / de-energized (user-
selectable)
• Latching/non-latching

Each CMON 2109 Machine protection relay Relay


module has 32 relays, for a maximum of 96 status
relays per 19 inch rack. All channels can LEDs
access all relays.
The relay module is software configur-
able, with no need for DIP switch settings.
Relay logic is flexible AND / OR / MAJORITY
Relay contacts
voting. on D-sub
connectors

Technical data
Relay specification
• Maximum switching voltage: Up to
60 V DC, 30 V RMS/42.4 V peak
• Maximum switching current: Maximum
2 A peak, maximum 1 A continuously
• Maximum switching capacity: 60 W,
62.5 VA
• Mechanical endurance: Typical 108 opera-
tions
• Electrical endurance: Minimum 105 oper-
ations at maximum rating
• Category of protection: Hermetically
sealed (RT V)

Physical
• 19 inch rack mounted
• Size: 6U high, 4TE wide
• Weight: 0,4 kg (14 oz.)

Environmental
• Temperature range: –20 to +65 °C
(–4 to +149 °F)
• Humidity: 95% relative humidity (non-
condensing)

10
CMON 2202
Power Supply module

Key features CMON 2202 Power Supply Power Supply input connector
• Four individual LED status indicators (one module (front view) board (part of backplane)
per Machine Protection and Condition (back view)
Monitoring module slot pair)
• Supports power supply redundancy

The CMON 2202 supplies power to the vari-


ous modules in the SKF Multilog IMx-M
rack. The power supply accepts AC (90 to
240 V AC/47 to 63 Hz). A single power sup-
ply can support a fully loaded rack. A second Future
power supply can provide redundancy. use

Power
presence
Technical data indicator
LEDs
Physical
• 19 inch rack mounted
• Size: 6U high, 12TE wide
Instrument
• Weight: 1,6 kg (56 oz.) ground /
protection
Environmental ground
• Temperature range: –20 to +65 °C
(–4 to +149 °F)
• Humidity: 95% relative humidity (non-
condensing)

Power supply
• 90 to 240 V AC, 47 to 63 Hz input voltage
• Maximum power consumption: 300 W
• Redundant option, individual main termi- Redundant
nal AC power
• Thermal and short circuit protection feed for
power
• Self-monitoring via PRM status informa- supply
tion and Relay Output option unit 1

Redundant
AC power
feed for
power
supply
unit 2

11
Mechanism for easy module extraction and custom label holders

Extracting modules
Simple extracting mechanisms with convenient handles located on
the top and bottom of each module makes it easy to extract and
replace modules.

Remove

Custom label holders


Simply slide out the protective plastic cover, place your own label,
and slide the plastic cover back to secure the label in place. Both top
and bottom handles can be used for customize labelling.

12
SKF Multilog IMx-M Manager

SKF Multilog IMx-M Manager (included with every unit), is a “stand Main function and features
alone” software tool for configuring and setting up the SKF Multilog • Allows for full setup and confutation of the SKF Multilog IMx-M
IMx-M. It provides a user friendly interface with logically ordered • USB interface for initial network setup
function and module layout, to simplify the complex task of config- • Rules for verifying all settings and pre-testing of made configura-
uring the SKF Multilog IMx-M. It includes test function, live displays, tion (dry run)
alarm / alert and measurement limits visualization and has built-in • Supports saving configuration files to SKF @ptitude Observer
rules that will warn you if settings are out of range or unsafe. It sup- database directly
ports the SKF Maintenance Mode which allows you to test all inputs • SKF Maintenance Mode with SAT report
on the system with a live display, aid in verifying relays and their • Live data display for verifying installation and settings
corresponding logic, and allows you to generate a SAT report. • Tools for upgrading of firmware to both Machine Protection and
Condition Monitoring modules
• Hierarchy with familiar plant layout (supports multiple SKF Multi-
log IMx-M units)

SKF Multilog IMx-M Manager


main interface.

Maintenance mode.

Measurement limits and configuration visualization. SAT report.

13
Scalable plantwide solutions for machinery monitoring
Typical non-hazardous area installation

Internet SKF @ptitude Monitoring Suite


SKF Remote Condition SKF @ptitude Decision Support
Monitoring Centers
Distributed
Reliability Control Reliability
server System (DCS) workstations
OPC server

Plant Information Network (PIN)


Ethernet Ethernet
Plant Control Network (PCN)
Redundant RS 485 Redundant RS 485
Relay Outputs

4 to 20 mA

Distributed
SKF Multilog SKF Control
IMx-M Multilog System
(API 670) IMx-S

4 to
20 mA

RS 485 SKF Machine Condition


Transmitters (MCT) (API 670)

SKF
Multilog
DMx
(API 670)
SKF Microlog

On-line
Main turbo-alternator sets Boiler feed pumps ID / FD fans process data

SKF offers comprehensive solutions for protection and condition SKF Multilog On-line System DMx
monitoring of all classes of rotating machinery, encompassing a API 670 features in a distributed field I/O format solution, located on
variety of architectures that can be scaled to optimize functionality the machine skid in the hazardous area. The SKF Multilog DMx com-
with respect to total installed cost. bines a high functionality in a small physical package that greatly
reduces field cable, and almost eliminates the need for instrument
SKF Multilog On-line System IMx-M room cabinets.
Provides a 19 inch rack format solution that is located in a non-haz-
ardous area such as an instrument or control room. The SKF Multi- SKF Multilog On-line System IMx-S
log IMx-M combines high functionality with high channel density, A multi-channel, on-line condition monitoring device suitable for
which leads to lower requirements for a cabinet and associated field installation in non-hazardous areas. The SKF Multilog IMx-S
infrastructure. provides fully automated monitoring and analysis capabilities and is
best suited for semi-critical and balance of plant equipment.

14
Scalable plantwide solutions for machinery monitoring
Typical hazardous area installation

Internet SKF @ptitude Monitoring Suite


SKF Remote Condition SKF @ptitude Decision Support
Monitoring Centers
Distributed
Reliability Control Reliability
server System (DCS) workstations
OPC server

Plant Information Network (PIN)


Ethernet Ethernet
Plant Control Network (PCN)
Redundant RS 485 Redundant RS 485
Relay Outputs
4 to 20 mA

Distributed
SKF Multilog SKF Control
IMx-M Multilog System
(API 670) IMx-S

4 to
Safety barrier* Safety barrier* Safety barrier* Safety barrier* 20 mA Safety barrier*

Safe area Safe area

RS 485 SKF Machine Condition


Transmitters (MCT) (API 670)
SKF
Multilog
DMx
(API 670)
SKF Microlog

On-line
process
Critical machines Critical machines Semi-critical machines Balance of plants Balance of plants
data
ATEX Zone 1 and NEC Class I Division 1 ATEX Zone 2 and NEC Class I Division 2

* NOTE: Declaration of Certification from MTL Instruments, MTL7700 series of Safety Barriers. 7796 for Eddy Probes and 7728 for accelerometers. For additional information,
please see their web site: http://www.mtl-inst.com or contact your SKF Representative.

SKF Machine Condition Transmitters (MCT) SKF @ptitude Monitoring Suite


Provides a range of simple single-point devices for providing tradi- Predictive maintenance software platform that brings all data from
tional 4 to 20 mA signals to the plant control system and basic field instruments together for processing into actionable information
machine trip functionality. regarding equipment reliability. The package provides the database
for complex dynamic vibration data, and provides plots and tools for
SKF Microlog Analyzer the experienced analyst. SKF @ptitide Decision Support is a data
SKF Microlog portable instruments offer a comprehensive range of reduction engine and knowledge base for automating much of the
predictive maintenance tools. analysis process. In addition, the cloud / server architecture allows
for remote diagnostic services.

15
Analytical tools from SKF @ptitude Monitoring Suite software

SKF @ptitude Monitoring Suite is a comprehensive software solu- SKF @ptitude Monitoring Suite allows your operations, maintenance
tion with powerful diagnostic and analytical capabilities. SKF and reliability staff to view data from different sources using the
@ptitude Monitoring Suite provides fast, efficient and reliable stor- same application and communicate information to other depart-
age, analysis, and retrieval of complex asset information and makes ments in a customizable format.
the information accessible throughout your organization. SKF SKF @ptitude Monitoring Suite integrates the range of SKF on-
@ptitude Monitoring Suite easily scales to your specific needs, line and off-line data collection devices into one enterprise-wide
whether it is operator inspection rounds, condition monitoring data software platform.
collection or in-depth vibration analysis and expert advice.

Spectra plot.

Time waveform plot.

Full Spectrum plot.

Bode plot.

Full Spectrum Topology plot.

16
Transducer systems

Eddy current probe systems Accelerometers and velocity sensors


SKF offers a full range of API 670 compliant non-contacting dis- SKF offers a full range of piezoelectric casing vibration sensors,
placement sensors (Eddy current probes) for use in critical machin- including models with NEC and ATEX agency approvals.
ery, including models with NEC and ATEX agency approvals.
General purpose industrial accelerometers
CMSS 65 / CMSS 665 series, 5 mm eddy probe system • CMSS 2100 Top exit, industrial accelerometer
• 5 mm tip diameter, 2 mm (80 mil) measurement range • CMSS 2200 Low profile, side exit, industrial accelerometer
• 5 m system length • CMSS 2106 High temperature, top exit, industrial accelerometer
• CMSS 65 Eddy current probe • CMSS 2207 High temperature, low profile, side exit, industrial
• CMSS 665 Driver accelerometer
• CMSS 958 Extension cable • CMSS 793V Piezoelectric industrial velocity sensor

CMSS 68 / CMSS 668 series, 8 mm eddy probe system Agency approved accelerometers*
• 8 mm tip diameter, 2,3 mm (90 mil) measurement range • CMSS 786A-IS and CMSS 786A-D2 CSA and ATEX approved,
• 5 m or 10 m system lengths intrinsically safe, general purpose, top exit, industrial accelero-
• CMSS 68 Eddy current probe meter
• CMSS 668 Driver • CMSS 787A-IS and CMSS 787A-D2 CSA and ATEX approved,
• CMSS 958 Extension cable intrinsically safe, general purpose, low profile, side exit, industrial
accelerometer
• CMSS 793-CA CSA approved, intrinsically safe, general purpose,
top exit, industrial accelerometer
• CMSS 793-EE ATEX approved, intrinsically safe, general purpose,
top exit, industrial accelerometer
• CMSS 793-FM Factory Mutual approved, intrinsically safe, gen-
eral purpose, top exit, industrial accelerometer
• CMSS 797-EE ATEX approved, intrinsically safe, general purpose,
low profile, ring mode, industrial accelerometer

* Installation must conform to hazardous area requirements when used in this


environment.

17
Wiring connector blocks

CMON 9010
Screw terminal block to be used for the relay connectors (use with CMON 9014
matching cable CMON 9011 or CMON 9012) Screw terminal block to be used for the 4 to 20 mA and / or buffered
analogue ouput connectors (use with matching cable CMON 9011 or
Specifications CMON 9012)

Physical Specifications
• Dimensions:
–– Width: 101.3 mm (3.9 in.) Physical
–– Height: 77 mm (3.0 in.) • Dimensions:
–– Depth): 58.5 mm (2.3 in.) –– Width: 101.3 mm (3.9 in.)
• Weight: 199 g (7.0 oz.) –– Height: 77 mm (3.0 in.)
–– Depth): 58.5 mm (2.3 in.)
Environmental • Weight: 199 g (7.0 oz.)
• Operating temperature: –20 to +50 °C (–4 to +122 °F)
• Storage/transport temperature: –20 to +70 °C (–4 to +158 °F) Environmental
• Operating temperature: –20 to +50 °C (–4 to +122 °F)
General • Storage/transport temperature: –20 to +70 °C (–4 to +158 °F)
• Nominal voltage UN: 125 V AC / DC
• Maximum current carrying capacity per branch: General
–– 2.5 A • Nominal voltage UN: 125 V AC/DC
–– 1.5 A (with even load on all branches) • Maximum current carrying capacity per branch:
• Number of positions: 37 –– 2.5 A
• Mounting position: Any –– 1.5 A (with even load on all branches)
• Standards / regulations: DIN EN 50178, IEC 60664, IEC 62103 • Number of positions: 37
• Pollution degree: 2 • Mounting position: Any
• Surge voltage category: II • Standards / regulations: DIN EN 50178, IEC 60664, IEC 62103
• Degree of protection: IP 20 • Pollution degree: 2
• Rated surge voltage: 1.2 kV (Functional insulation) • Surge voltage category: II
• Rated insulation voltage: 125 V • Degree of protection: IP 20
• Rated surge voltage: 1.2 kV (Functional insulation)
Connection data for connection 1 • Rated insulation voltage: 125 V
• Connection name: PCB connection
• Connection in accordance with standard: IEC/EN Connection data for connection 1
• Connection method: Screw connection • Connection name: PCB connection
• Conductor cross section solid minimum: 0.2 mm² • Connection in accordance with standard: IEC/EN
• Conductor cross section solid maximum: 4 mm² • Connection method: Screw connection
• Conductor cross section stranded minimum: 0.2 mm² • Conductor cross section solid minimum: 0.2 mm²
• Conductor cross section stranded maximum: 2.5 mm² • Conductor cross section solid maximum: 4 mm²
• Conductor cross section AWG/kcmil minimum: 24 • Conductor cross section stranded minimum: 0.2 mm²
• Conductor cross section AWG/kcmil maximum: 12 • Conductor cross section stranded maximum: 2.5 mm²
• Stripping length: 8 mm • Conductor cross section AWG / kcmil minimum: 24
• Screw thread: M3 • Conductor cross section AWG / kcmil maximum: 12
• Stripping length: 8 mm
Classifications • Screw thread: M3
• eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0 Classifications
• UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2 • eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0
Approvals • UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2
• UL Recognized / cUL Recognized / GOST / cULus Recognized
Approvals
• UL Recognized / cUL Recognized / GOST / cULus Recognized

18
Wiring connector blocks Cables

CMON 9016 Specifications


Screw terminal block to be used for the Digital connectors (use with Common specifications for the following cable models (specification
matching cable CMON 9017 and CMON 9018) differences as noted on each product description):

Specifications • CMON 9011


• CMON 9012
Physical • CMON 9013
• Dimensions: • CMON 9015
–– Width: 44.9 mm (1.8 in.) • CMON 9017
–– Height: 65.5 mm (2.6 in.) • CMON 9018
–– Depth): 45.1 mm (1.8 in.) • CMON 9019
• Weight: 100 g (3.5 oz.)
Environmental
Environmental • Operating temperature: –20 to +50 °C (–4 to +122 °F)
• Operating temperature: –20 to +50 °C (–4 to +122 °F) • Storage / transport temperature: –20 to +70 °C (–4 to +158 °F)
• Storage/transport temperature: –20 to +70 °C (–4 to +158 °F) • Flame resistance: IEC 60332-1

General General
• Nominal voltage UN: 125 V AC/DC • Nominal voltage UN: 125 V AC/DC
• Maximum current carrying capacity per branch: • Maximum current carrying capacity per path: 2 A
–– 2.5 A • Maximum conductor resistance: ≤0.09 Ω/m
–– 1.5 A (with even load on all branches) • Single wire, cross section: 0.25 mm²
• Number of positions: 15 • AWG: 24
• Status display: No • Shielding: Yes, tinned copper-braided shield, approximately 85%
• Mounting position: Any covering
• Insertion / withdrawal cycles: >200
Connection data for connection 1
• Connection name: PCB connection Classifications
• Connection in accordance with standard: IEC/EN • eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• Connection method: Screw connection • ETIM: 2.0, 3.0, 4.0, 5.0
• Number of positions: 15 • UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2
• Conductor cross section solid minimum: 0.2 mm²
• Conductor cross section solid maximum: 4 mm² Approvals
• Conductor cross section stranded minimum: 0.2 mm² • UL Recognized / cUL Recognized / GOST / cULus Recognized
• Conductor cross section stranded maximum: 2.5 mm²
• Conductor cross section AWG/kcmil minimum: 24
• Conductor cross section AWG/kcmil maximum: 12
• Stripping length: 8 mm
• Screw thread: M3

Connection data for connection 2


• Connection name: D-SUB connection
• Number of connections: 1
• Connection method: High density D-SUB pin strip
• Number of positions: 15

Classifications
• eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0
• UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2

Approvals
• UL Recognized / cUL Recognized / GOST / cULus Recognized

19
Cables

CMON 9011 CMON 9012 CMON 9013


Cable with one male and one female D-type Cable with one male and one female D-type Cable to be used for the Relay connector,
connector to be used for the relay connec- connector to be used for the relay connec- wiring to a normal terminal block interface.
tion. Connects between the relay output tion. Connects between the relay output Cable length: 2 meters.
connector and a matching screw terminal connector and a matching screw terminal
block e.g. CMON 9010. block e.g. CMON 9010.

Specifications

Physical
• Cable length: 2 meters (6.6 feet)
Specifications Specifications • Weight: 460 g (16.2 oz.)

Physical Physical General


• Cable length: 1 meter (3.3 feet) • Cable length: 2 meters (6.6 feet) • External diameter: 12 mm
• Weight: 304 g (10.7 oz.) • Weight: 510 g (10.7 oz.)
Connection: module side
General General • Number of positions: 37
• External diameter: 12.5 mm • External diameter: 12.5 mm • Connectors: D-SUB socket strip
• Number of plugs: 1
Connection: module side Connection: module side
• Number of positions: 37 • Number of positions: 37 Connector: controller side
• Connectors: D-SUB socket strip • Connectors: D-SUB socket strip • Number of positions: 37
• Number of plugs: 1 • Number of plugs: 1 • Connectors: Open end
• Number of plugs: 0
Connector: controller side Connector: controller side
• Number of positions: 37 • Number of positions: 37
• Connectors: D-SUB pin strip • Connectors: D-SUB pin strip
• Number of plugs: 1 • Number of plugs: 1

20
Cables

CMON 9015 CMON 9017


Cable to be used for the 4 to 20 mA connector wiring to a normal Cable with D-type connector to be used for the Digital connection.
terminal block. Cable length: 2 meters. Connects between the Digital output connector and a matching
screw terminal block CMON 9016. Cable length: 1.5 meters.
Specifications
Specifications

Physical
• Cable length: 2 meters (6.6 feet)
• Weight: 333 g (11.7 oz.) Physical
• Cable length: 1.5 meters (4.9 feet)
General • Weight: 200 g (7.0 oz.)
• External diameter: 12 mm
General
Connection: module side • External diameter: 9.0 mm
• Number of positions: 37
• Connectors: D-SUB pin strip Connection: module side
• Number of plugs: 1 • Number of positions: 15
• Connectors: D-SUB socket strip
Connector: controller side • Number of plugs: 1
• Number of positions: 37
• Connectors: Open end Connector: controller side
• Number of plugs: 0 • Number of positions: 15
• Connectors: D-SUB pin strip
• Number of plugs: 1

21
Cables

CMON 9018 CMON 9019


Cable with D-type connector to be used for the Digital connection. Cable to be used for the Digital connector wiring to a normal termi-
Connects between the Digital output connector and a matching nal block. Cable length: 3 meters.
screw terminal block CMON 9016. Cable length: 3 meters.

Specifications

Physical
Specifications • Cable length: 3 meters (9.8 feet)
• Weight: 333 g (11.7 oz.)
Physical
• Cable length: 3 meters (9.8 feet) General
• Weight: 349 g (12.3 oz.) • External diameter: 9 mm

General Connection: module side


• External diameter: 9.0 mm • Number of positions: 15
• Connectors: D-SUB pin strip
Connection: module side • Number of plugs: 1
• Number of positions: 15
• Connectors: D-SUB socket strip Connector: controller side
• Number of plugs: 1 • Number of positions: 15
• Connectors: Open end
Connector: controller side • Number of plugs: 0
• Number of positions: 15
• Connectors: D-SUB pin strip
• Number of plugs: 1

22
Miscellaneous

CMON 2131 CMON 2132


SKF Multilog IMx-M blank cover plate kit (to cover slots without SKF Multilog IMx-M spare connector kit. Contains spare green ter-
modules in them). The blank cover plate kit includes: minal connectors for one Machine Protection and Condition Moni-
toring module pair and all connectors needed on the power supply.
• One (1) each, Power Supply module cover plate
• Four (4) each, Machine Protection module cover plates (front,
including handles)
• Four (4) each, Condition Monitoring module plates (front, includ-
ing handles)
• Four (4) each, Machine Protection plus Condition Monitoring Con-
nector board cover plate (rear plate, example picture below)
• Three (3) each, Relay modules (front, including handles)
• Three (3) each, Relay Connector board cover plate (rear, example
picture below)

CMON 2133
Isolated USB cable set for use with the SKF Multilog IMx-M (con-
tains two USB cables).
NOTE: One (1) set each, CMON 2133 is included with every SKF Multilog IMx-M
shipped.

Isolator USB connector cable.

Machine Protection plus Relay module


Condition Monitoring blank cover plate
Connector blank cover (rear)
plate (rear) Isolator mini USB connector cable.

23
Ordering information

SKF Multilog On-line System IMx-M Standard rack part numbers for the SKF Multilog On-line System
(necessary rear connector boards and SKF Multilog IMx-M Manager IMx-M (necessary rear connector boards and SKF Multilog IMx-M
included) Manager included)

Part number CMON 5000–aa-b-cc Standard rack part Description – SKF Multilog IMx-M rack
numbers with:
aa Number of channels
16 16 channels CMON 5000-16-2-0 16 channels, 2 power supplies
32 32 channels CMON 5000-16-2-32 16 channels, 2 power supplies, 32 relays
48 48 channels
64 64 channels CMON 5000-32-2-0 32 channels, 2 power supplies
CMON 5000-32-2-32 32 channels, 2 power supplies, 32 relays
b Number of power supplies CMON 5000-32-2-64 32 channels, 2 power supplies, 64 relays
1 1 power supply
2 2 power supplies CMON 5000-48-2-0 48 channels, 2 power supplies
CMON 5000-48-2-32 48 channels, 2 power supplies, 32 relays
cc Number of relays CMON 5000-48-2-64 48 channels, 2 power supplies, 64 relays
32 32 relays CMON 5000-48-2-96 48 channels, 2 power supplies, 96 relays
64 64 relays (for 32, 48 or 64 channels only)
96 96 relays (for 48 or 64 channels only) CMON 5000-64-2-0 64 channels, 2 power supplies
CMON 5000-64-2-32 64 channels, 2 power supplies, 32 relays
For example, CMON 5000-16-2-32: SKF Multilog IMx-M rack with 16 CMON 5000-64-2-64 64 channels, 2 power supplies, 64 relays
channel, 2 power supplies, 32 relays and the necessary rear connector CMON 5000-64-2-96 64 channels, 2 power supplies, 96 relays
boards.
Contact the Customer Service Group (CSG), SKF Condition Monitoring
Center – Lulea at CSG-Lulea@skf.com for other CMON 5000 part
numbers.

Add-on modules: Components:


• CMON 5000-16-AN: 16 channel Machine Protection and Condi- • CMON 2007: 19 inch rack enclosure including backplane and
tion Monitoring add-on module pair, including rear connector power terminal card
board (CMON 2118) • CMON 2102: Machine Protection module (maximum four per
• CMON 5000-32-RE: 32 channel Relay add-on module, including rack)
rear relay input / output connector board (CMON 2119) • CMON 2103: Condition Monitoring module (one per CMON 2102)
• CMON 2109: Relay module
• CMON 2118: Machine Protection and Condition Monitoring pair
input / output rear connector board (maximum four per pack)
• CMON 2119: Relay module input / output rear connector board
(one per installed relay module)
• CMON 2202: Power Supply unit (maximum two per rack)

24
Ordering information – accessories / spare parts

Wiring connector blocks Miscellaneous


• CMON 9010: Screw terminal block to be used for the relay con- • CMON 2131: SKF Multilog IMx-M blanking plate kit (to cover slots
nectors (use with matching cable CMON 9011 or CMON 9012) without modules in them). The blank cover plate kit includes:
• CMON 9014: Screw terminal block to be used for the 4 to 20 mA –– Two (2) each Power Supply module plates
and / or buffered analogue ouput connectors (use with matching –– Four (4) each Machine Protection module plates
cable CMON 9011 or CMON 9012) –– Four (4) each Condition Monitoring module plates
• CMON 9016: Screw terminal block to be used for the Digital con- –– Three (3) each Relay module plates
nectors (use with matching cable CMON 9017 and CMON 9018) • CMON 2132: SKF Multilog IMx-M spare connector kit. Contains
spare green terminal connectors for one Machine Protection and
Cables Condition Monitoring module pair and all connectors needed on
• CMON 9011: Cable with one male and one female D-type con- the power supply.
nector to be used for the relay connection. Connects between the • CMON 2133: Isolated USB cable set for use with the SKF Multilog
relay output connector and a matching screw terminal block e.g. IMx-M (contains two USB cables).
CMON 9010. Cable length: 1 meter (3.3 feet).
• CMON 9012: Cable with one male and one female D-type con-
nector to be used for the relay connection. Connects between the Installation and training
relay output connector and a matching screw terminal block e.g. Installation and training available through your local SKF supplier or
CMON 9010. Cable length: 2 meters (6.6 feet). representative.
• CMON 9013: Cable to be used for the Relay connector, wiring to a
normal terminal block interface. Cable length: 2 meters (6.6 feet).
• CMON 9015: Cable to be used for the 4 to 20 mA connector wir- Product Support Plans (PSP)
ing to a normal terminal block. Cable length: 2 meters (6.6 feet). A range of Product Support Plans is available to protect your invest-
• CMON 9017: Cable with D-type connector to be used for the Dig- ment. Contact your local SKF representative for additional informa-
ital connection. Connects between the Digital output connector tion.
and a matching screw terminal block CMON 9016. Cable length:
1.5 meters (4.9 feet).
• CMON 9018: Cable with D-type connector to be used for the Dig-
ital connection. Connects between the Digital output connector
and a matching screw terminal block CMON 9016. Cable length: 3
meters (9.8 feet).
• CMON 9019: Cable to be used for the Digital connector wiring to
a normal terminal block. Cable length: 3 meters (9.8 feet).

25
The Power of Knowledge Engineering

Seals
Bearings Lubrication Drawing on five areas of competence and application-specific expertise amassed over more than 100
and units systems years, SKF brings innovative solutions to OEMs and production facilities in every major industry world-
wide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
Mechatronics Services
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.

Please contact:
SKF Condition Monitoring Center – Luleå
Aurorum 30, S-977 75 • Luleå, Sweden
Tel: +46 (0) 31 337 10 00 • Fax: +46 (0) 920 134 40
Web: www.skf.com/cm

® SKF, @PTITUDE, MICROLOG and MULTILOG are registered trademarks of the SKF Group.
All other trademarks are the property of their respective owners.
© SKF Group 2015
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
SKF reserves the right to alter any part of this publication without prior notice.
Patents: US 4,768,380 · US 5,633,811 · US 5,679,900 · US 5,845,230 · US 5,852,351 ·
US 5,854,553 · US 5,854,994 · US 5,870,699 · US 5,907,491 · US 5,992,237 · US 6,006,164 ·
US 6,124,692 · US 6,138,078 · US 6,199,422 · US 6,202,491 · US 6,275,781 · US 6,301,514 ·
US 6,437,692 · US 6,489,884 · US 6,513,386 · US 6,633,822 · US 6,789,025 · US 6,792,360 ·
US 7,103,511 · US 7,697,492 · WO/2003/048714

PUB CM/P8 11416/4 EN · April 2015

skf.com

You might also like