Professional Documents
Culture Documents
System IMx-M
State of the art solution for
protecting and enhancing
the reliability of your
critical machinery
The SKF Multilog On-line System IMx-M is • Simultaneous measurement of all input
the latest addition to the current generation channels
of powerful, cost effective solutions suitable • Redundant Modbus RTU communications
for a variety of machinery monitoring appli- • Buffered outputs front and rear
cations. Together with SKF @ptitude Moni- • Local status indication and display
toring Suite software, the SKF Multilog • Flexible voting logic
IMx-M can provide a complete system for • Customizable filters
initiation of machinery shutdown, early fault
detection, and diagnosis. In addition, the
SKF Multilog IMx-M system can provide Machine condition monitoring
automated advice for correcting existing or • Independent of machine protection
impending conditions which can affect • DC to 40 kHz frequency range
machine reliability, availability and perform- • Overall level and vector processing
ance. • Spectrum with up to 6 400 line resolution
• Transient and steady-state data capture
10
4 2
7
8
1 1 3 3 3
10
5 5 5 5
2
SKF Multilog IMx-M system overview – rear view
13 5
11 11
12 5
10 10
14
5 4
6
8
7
9
1 1 1 1 2 2 2 3
3
System modules, components and Certifications
technical data • CE conformity according to EN 61000-6-4:2007,
EN 61000-6-2:2005, EN/IEC 61010-1:2010,
• CMON 2007 19 inch rack with backplane and power supply con- EN/IEC 61010-1:2001
nections († page 4) • ETL certified according to UL 61010-1 2nd Edition,
• CMON 2102 Machine Protection module († page 6) CAN/CSA-22.2 no. 61010-1 2nd Edition
• CMON 2103 Machine Protection and Condition Monitoring mod- • IEC 61010-1: 2010
ule pair, input / output connector board († page 8) • IEC 61010-1: 2001
• CMON 2118 Condition Monitoring module († pages 6 and 8) • CAN/CSA 22.2, no. 61010-1, 2nd Edition
• CMON 2109 Relay module († page 10) • UL 61010-1, 2nd Edition
• CMON 2119 Relay module, input / output connector board • AS 61010-1: 2003
(† page 10)
• CMON 2202 Power Supply module († page 11)
Specific design requirements
• Designed to comply with API 670
CMON 2007
19 inch rack with backplane (including power supply connectors)
Key features one module pair, cannot influence another • Redundant power bus to Machine Protec-
• Standard 19 inch rack mounted module pair. All modules are inserted from tion and Condition Monitoring modules,
• Standard 6U height the front side of the rack. On the rack rear, total eight per rack (4 pairs)
• Robust aluminium design there are termination boards for each mod-
ule set. Physical
The 19 inch rack enclosure contains the • 19 inch rack mounted, 6U high
electronics of the SKF Multilog IMx-M. • Dimensions:
Each rack holds up to four Machine Pro- Technical data –– Height: 266 mm (10.47 in.)
tection and Condition Monitoring module –– Width: 482 mm (18.98 in.)
pairs, three relay cards and up to two Backplane –– Depth: 240 mm (9.45 in.)
redundant power supplies. The rack has a • Two slots for power supplies • Weight (bare rack): 3,5 kg (123 oz.)
backplane providing electric interconnection • Four, two slot pairs (one Machine Protec-
between Condition Monitoring and Machine tion and one Condition Monitoring mod- Environmental
Protection module pairs, relay cards and ule, always mounted in pairs) • Temperature range: –20 to +65 °C
power supplies. All module pairs are 100% • Three slots for relay cards (–4 to +149 °F)
isolated from one another so that failure of • Screw terminals, RJ45 and D-sub con- • Humidity: 95% relative humidity (non-
nectors on rear of unit condensing)
4
CMON 2007 Rack dimensions
27,8 mm 27,8 mm
(1.1 in.) 426,7 mm (1.1 in.)
(16.8 in.)
265,9 mm
(10.5 in.)
190,5 mm
(7.5 in.)
435,8 mm
(17.2 in.)
213 mm
(8.4 in.)
14 mm
(0.6 in.) 213 mm
(8.4 in.)
5
CMON 2102
Machine Protection module
Outputs
• 16 rear analog buffered outputs, cutoff • Dual digital communications link
frequency (–3 dB) at 60 kHz –– Alarm status, channel value, OK limits,
• 8 rear digital buffered outputs alarm setpoints, diagnostics, trip multi-
• Two analog buffered outputs at front ply status, channel enabled / disabled,
(user selectable output channel) slot enabled / disabled
• One digital buffered output at front (user
selectable output channel)
• Single 4 to 20 mA output per analog
channel
6
Processing kW, MW, %, mH, T, °, kg/cm2, cmHg, um, ·· User defined filters (1 Hz steps from
• Radial shaft vibration (Overall: displace- mm, g, mm/s, mils, ips) 1 Hz to 2400, 4800 Hz)
ment) • TSI functions (absolute shaft vibration, –– Roll-off rate: 24 dB/oct
• GAP / Bias eccentricity (direct) and complementary • Digital / Speed processing
• Casing vibration (velocity, acceleration) differential expansion) –– Peak Speed
• Absolute shaft vibration • Piston rod drop (average / triggered)
• Position • Filters: Interface
• RPM: 0,1 Hz to 7,5 kHz (eddy current –– Programmable selections • USB service interface
probe minimum >2 Hz / 120 rpm, GAP ·· 5 to 1 000 Hz, 10 to 1 000 Hz, 1 to • RS 485, Modbus, redundant, bi-direc-
dependent) 600 Hz, 4 to 4 000 Hz, 10 to 5 000 tional
• Detection: true Peak to Peak, true Zero to Hz, 1 to 10 000 Hz, displacement,
Peak (“true Peak to Peak” / 2), true RMS velocity and acceleration Other
• Temperature (°C, °F) ·· 10 to 5 000 Hz and 1 000 to • Local storage of minimum 1 400 events
• Static parameters (psi, bar, mbar, hPa, Pa, 10 000 Hz, acceleration and velocity, per Machine Protection module
MPa, kPA, mA, A, mV, V, kV, kVA, C, F, W, single channel on a paired channel
group and no integration
Analog
buffered
Module outputs
status LED
Channel
status LED 4 to 20 mA
outputs
Redundant
RS 485 LEDs
Analog buffered
outputs
Redundant
RS 485
(protection) Status relays
7
CMON 2103
Condition Monitoring module
8
Protection LCD and keypad Interface On-board data storage (typical, per
• Set-up menu • Ethernet: 10/100 Mbit RJ45, TCP/IP module)
• Bargraph • Built-in two port data switch, 10/100 • 1 400 latest events
• Buffered output front selection Base-T • 13 000 vibration trend values
• Channel values • USB service interface • 1 000 spectra (400 lines)
Local display:
• Bargraph
• Buffered output
front selection
• Channel values
Local display
selection keypad
Ethernet
connection
status LEDs
9
CMON 2109
Relay module
Technical data
Relay specification
• Maximum switching voltage: Up to
60 V DC, 30 V RMS/42.4 V peak
• Maximum switching current: Maximum
2 A peak, maximum 1 A continuously
• Maximum switching capacity: 60 W,
62.5 VA
• Mechanical endurance: Typical 108 opera-
tions
• Electrical endurance: Minimum 105 oper-
ations at maximum rating
• Category of protection: Hermetically
sealed (RT V)
Physical
• 19 inch rack mounted
• Size: 6U high, 4TE wide
• Weight: 0,4 kg (14 oz.)
Environmental
• Temperature range: –20 to +65 °C
(–4 to +149 °F)
• Humidity: 95% relative humidity (non-
condensing)
10
CMON 2202
Power Supply module
Key features CMON 2202 Power Supply Power Supply input connector
• Four individual LED status indicators (one module (front view) board (part of backplane)
per Machine Protection and Condition (back view)
Monitoring module slot pair)
• Supports power supply redundancy
Power
presence
Technical data indicator
LEDs
Physical
• 19 inch rack mounted
• Size: 6U high, 12TE wide
Instrument
• Weight: 1,6 kg (56 oz.) ground /
protection
Environmental ground
• Temperature range: –20 to +65 °C
(–4 to +149 °F)
• Humidity: 95% relative humidity (non-
condensing)
Power supply
• 90 to 240 V AC, 47 to 63 Hz input voltage
• Maximum power consumption: 300 W
• Redundant option, individual main termi- Redundant
nal AC power
• Thermal and short circuit protection feed for
power
• Self-monitoring via PRM status informa- supply
tion and Relay Output option unit 1
Redundant
AC power
feed for
power
supply
unit 2
11
Mechanism for easy module extraction and custom label holders
Extracting modules
Simple extracting mechanisms with convenient handles located on
the top and bottom of each module makes it easy to extract and
replace modules.
Remove
12
SKF Multilog IMx-M Manager
SKF Multilog IMx-M Manager (included with every unit), is a “stand Main function and features
alone” software tool for configuring and setting up the SKF Multilog • Allows for full setup and confutation of the SKF Multilog IMx-M
IMx-M. It provides a user friendly interface with logically ordered • USB interface for initial network setup
function and module layout, to simplify the complex task of config- • Rules for verifying all settings and pre-testing of made configura-
uring the SKF Multilog IMx-M. It includes test function, live displays, tion (dry run)
alarm / alert and measurement limits visualization and has built-in • Supports saving configuration files to SKF @ptitude Observer
rules that will warn you if settings are out of range or unsafe. It sup- database directly
ports the SKF Maintenance Mode which allows you to test all inputs • SKF Maintenance Mode with SAT report
on the system with a live display, aid in verifying relays and their • Live data display for verifying installation and settings
corresponding logic, and allows you to generate a SAT report. • Tools for upgrading of firmware to both Machine Protection and
Condition Monitoring modules
• Hierarchy with familiar plant layout (supports multiple SKF Multi-
log IMx-M units)
Maintenance mode.
13
Scalable plantwide solutions for machinery monitoring
Typical non-hazardous area installation
4 to 20 mA
Distributed
SKF Multilog SKF Control
IMx-M Multilog System
(API 670) IMx-S
4 to
20 mA
SKF
Multilog
DMx
(API 670)
SKF Microlog
On-line
Main turbo-alternator sets Boiler feed pumps ID / FD fans process data
SKF offers comprehensive solutions for protection and condition SKF Multilog On-line System DMx
monitoring of all classes of rotating machinery, encompassing a API 670 features in a distributed field I/O format solution, located on
variety of architectures that can be scaled to optimize functionality the machine skid in the hazardous area. The SKF Multilog DMx com-
with respect to total installed cost. bines a high functionality in a small physical package that greatly
reduces field cable, and almost eliminates the need for instrument
SKF Multilog On-line System IMx-M room cabinets.
Provides a 19 inch rack format solution that is located in a non-haz-
ardous area such as an instrument or control room. The SKF Multi- SKF Multilog On-line System IMx-S
log IMx-M combines high functionality with high channel density, A multi-channel, on-line condition monitoring device suitable for
which leads to lower requirements for a cabinet and associated field installation in non-hazardous areas. The SKF Multilog IMx-S
infrastructure. provides fully automated monitoring and analysis capabilities and is
best suited for semi-critical and balance of plant equipment.
14
Scalable plantwide solutions for machinery monitoring
Typical hazardous area installation
Distributed
SKF Multilog SKF Control
IMx-M Multilog System
(API 670) IMx-S
4 to
Safety barrier* Safety barrier* Safety barrier* Safety barrier* 20 mA Safety barrier*
On-line
process
Critical machines Critical machines Semi-critical machines Balance of plants Balance of plants
data
ATEX Zone 1 and NEC Class I Division 1 ATEX Zone 2 and NEC Class I Division 2
* NOTE: Declaration of Certification from MTL Instruments, MTL7700 series of Safety Barriers. 7796 for Eddy Probes and 7728 for accelerometers. For additional information,
please see their web site: http://www.mtl-inst.com or contact your SKF Representative.
15
Analytical tools from SKF @ptitude Monitoring Suite software
SKF @ptitude Monitoring Suite is a comprehensive software solu- SKF @ptitude Monitoring Suite allows your operations, maintenance
tion with powerful diagnostic and analytical capabilities. SKF and reliability staff to view data from different sources using the
@ptitude Monitoring Suite provides fast, efficient and reliable stor- same application and communicate information to other depart-
age, analysis, and retrieval of complex asset information and makes ments in a customizable format.
the information accessible throughout your organization. SKF SKF @ptitude Monitoring Suite integrates the range of SKF on-
@ptitude Monitoring Suite easily scales to your specific needs, line and off-line data collection devices into one enterprise-wide
whether it is operator inspection rounds, condition monitoring data software platform.
collection or in-depth vibration analysis and expert advice.
Spectra plot.
Bode plot.
16
Transducer systems
CMSS 68 / CMSS 668 series, 8 mm eddy probe system Agency approved accelerometers*
• 8 mm tip diameter, 2,3 mm (90 mil) measurement range • CMSS 786A-IS and CMSS 786A-D2 CSA and ATEX approved,
• 5 m or 10 m system lengths intrinsically safe, general purpose, top exit, industrial accelero-
• CMSS 68 Eddy current probe meter
• CMSS 668 Driver • CMSS 787A-IS and CMSS 787A-D2 CSA and ATEX approved,
• CMSS 958 Extension cable intrinsically safe, general purpose, low profile, side exit, industrial
accelerometer
• CMSS 793-CA CSA approved, intrinsically safe, general purpose,
top exit, industrial accelerometer
• CMSS 793-EE ATEX approved, intrinsically safe, general purpose,
top exit, industrial accelerometer
• CMSS 793-FM Factory Mutual approved, intrinsically safe, gen-
eral purpose, top exit, industrial accelerometer
• CMSS 797-EE ATEX approved, intrinsically safe, general purpose,
low profile, ring mode, industrial accelerometer
17
Wiring connector blocks
CMON 9010
Screw terminal block to be used for the relay connectors (use with CMON 9014
matching cable CMON 9011 or CMON 9012) Screw terminal block to be used for the 4 to 20 mA and / or buffered
analogue ouput connectors (use with matching cable CMON 9011 or
Specifications CMON 9012)
Physical Specifications
• Dimensions:
–– Width: 101.3 mm (3.9 in.) Physical
–– Height: 77 mm (3.0 in.) • Dimensions:
–– Depth): 58.5 mm (2.3 in.) –– Width: 101.3 mm (3.9 in.)
• Weight: 199 g (7.0 oz.) –– Height: 77 mm (3.0 in.)
–– Depth): 58.5 mm (2.3 in.)
Environmental • Weight: 199 g (7.0 oz.)
• Operating temperature: –20 to +50 °C (–4 to +122 °F)
• Storage/transport temperature: –20 to +70 °C (–4 to +158 °F) Environmental
• Operating temperature: –20 to +50 °C (–4 to +122 °F)
General • Storage/transport temperature: –20 to +70 °C (–4 to +158 °F)
• Nominal voltage UN: 125 V AC / DC
• Maximum current carrying capacity per branch: General
–– 2.5 A • Nominal voltage UN: 125 V AC/DC
–– 1.5 A (with even load on all branches) • Maximum current carrying capacity per branch:
• Number of positions: 37 –– 2.5 A
• Mounting position: Any –– 1.5 A (with even load on all branches)
• Standards / regulations: DIN EN 50178, IEC 60664, IEC 62103 • Number of positions: 37
• Pollution degree: 2 • Mounting position: Any
• Surge voltage category: II • Standards / regulations: DIN EN 50178, IEC 60664, IEC 62103
• Degree of protection: IP 20 • Pollution degree: 2
• Rated surge voltage: 1.2 kV (Functional insulation) • Surge voltage category: II
• Rated insulation voltage: 125 V • Degree of protection: IP 20
• Rated surge voltage: 1.2 kV (Functional insulation)
Connection data for connection 1 • Rated insulation voltage: 125 V
• Connection name: PCB connection
• Connection in accordance with standard: IEC/EN Connection data for connection 1
• Connection method: Screw connection • Connection name: PCB connection
• Conductor cross section solid minimum: 0.2 mm² • Connection in accordance with standard: IEC/EN
• Conductor cross section solid maximum: 4 mm² • Connection method: Screw connection
• Conductor cross section stranded minimum: 0.2 mm² • Conductor cross section solid minimum: 0.2 mm²
• Conductor cross section stranded maximum: 2.5 mm² • Conductor cross section solid maximum: 4 mm²
• Conductor cross section AWG/kcmil minimum: 24 • Conductor cross section stranded minimum: 0.2 mm²
• Conductor cross section AWG/kcmil maximum: 12 • Conductor cross section stranded maximum: 2.5 mm²
• Stripping length: 8 mm • Conductor cross section AWG / kcmil minimum: 24
• Screw thread: M3 • Conductor cross section AWG / kcmil maximum: 12
• Stripping length: 8 mm
Classifications • Screw thread: M3
• eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0 Classifications
• UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2 • eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0
Approvals • UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2
• UL Recognized / cUL Recognized / GOST / cULus Recognized
Approvals
• UL Recognized / cUL Recognized / GOST / cULus Recognized
18
Wiring connector blocks Cables
General General
• Nominal voltage UN: 125 V AC/DC • Nominal voltage UN: 125 V AC/DC
• Maximum current carrying capacity per branch: • Maximum current carrying capacity per path: 2 A
–– 2.5 A • Maximum conductor resistance: ≤0.09 Ω/m
–– 1.5 A (with even load on all branches) • Single wire, cross section: 0.25 mm²
• Number of positions: 15 • AWG: 24
• Status display: No • Shielding: Yes, tinned copper-braided shield, approximately 85%
• Mounting position: Any covering
• Insertion / withdrawal cycles: >200
Connection data for connection 1
• Connection name: PCB connection Classifications
• Connection in accordance with standard: IEC/EN • eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• Connection method: Screw connection • ETIM: 2.0, 3.0, 4.0, 5.0
• Number of positions: 15 • UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2
• Conductor cross section solid minimum: 0.2 mm²
• Conductor cross section solid maximum: 4 mm² Approvals
• Conductor cross section stranded minimum: 0.2 mm² • UL Recognized / cUL Recognized / GOST / cULus Recognized
• Conductor cross section stranded maximum: 2.5 mm²
• Conductor cross section AWG/kcmil minimum: 24
• Conductor cross section AWG/kcmil maximum: 12
• Stripping length: 8 mm
• Screw thread: M3
Classifications
• eCl@ss: 4.0, 4.1, 5.0, 5.1, 6.0, 7.0, 8.0
• ETIM: 2.0, 3.0, 4.0, 5.0
• UNSPSC: 6.01, 7.0901, 11, 12.01, 13.2
Approvals
• UL Recognized / cUL Recognized / GOST / cULus Recognized
19
Cables
Specifications
Physical
• Cable length: 2 meters (6.6 feet)
Specifications Specifications • Weight: 460 g (16.2 oz.)
20
Cables
Physical
• Cable length: 2 meters (6.6 feet)
• Weight: 333 g (11.7 oz.) Physical
• Cable length: 1.5 meters (4.9 feet)
General • Weight: 200 g (7.0 oz.)
• External diameter: 12 mm
General
Connection: module side • External diameter: 9.0 mm
• Number of positions: 37
• Connectors: D-SUB pin strip Connection: module side
• Number of plugs: 1 • Number of positions: 15
• Connectors: D-SUB socket strip
Connector: controller side • Number of plugs: 1
• Number of positions: 37
• Connectors: Open end Connector: controller side
• Number of plugs: 0 • Number of positions: 15
• Connectors: D-SUB pin strip
• Number of plugs: 1
21
Cables
Specifications
Physical
Specifications • Cable length: 3 meters (9.8 feet)
• Weight: 333 g (11.7 oz.)
Physical
• Cable length: 3 meters (9.8 feet) General
• Weight: 349 g (12.3 oz.) • External diameter: 9 mm
22
Miscellaneous
CMON 2133
Isolated USB cable set for use with the SKF Multilog IMx-M (con-
tains two USB cables).
NOTE: One (1) set each, CMON 2133 is included with every SKF Multilog IMx-M
shipped.
23
Ordering information
SKF Multilog On-line System IMx-M Standard rack part numbers for the SKF Multilog On-line System
(necessary rear connector boards and SKF Multilog IMx-M Manager IMx-M (necessary rear connector boards and SKF Multilog IMx-M
included) Manager included)
Part number CMON 5000–aa-b-cc Standard rack part Description – SKF Multilog IMx-M rack
numbers with:
aa Number of channels
16 16 channels CMON 5000-16-2-0 16 channels, 2 power supplies
32 32 channels CMON 5000-16-2-32 16 channels, 2 power supplies, 32 relays
48 48 channels
64 64 channels CMON 5000-32-2-0 32 channels, 2 power supplies
CMON 5000-32-2-32 32 channels, 2 power supplies, 32 relays
b Number of power supplies CMON 5000-32-2-64 32 channels, 2 power supplies, 64 relays
1 1 power supply
2 2 power supplies CMON 5000-48-2-0 48 channels, 2 power supplies
CMON 5000-48-2-32 48 channels, 2 power supplies, 32 relays
cc Number of relays CMON 5000-48-2-64 48 channels, 2 power supplies, 64 relays
32 32 relays CMON 5000-48-2-96 48 channels, 2 power supplies, 96 relays
64 64 relays (for 32, 48 or 64 channels only)
96 96 relays (for 48 or 64 channels only) CMON 5000-64-2-0 64 channels, 2 power supplies
CMON 5000-64-2-32 64 channels, 2 power supplies, 32 relays
For example, CMON 5000-16-2-32: SKF Multilog IMx-M rack with 16 CMON 5000-64-2-64 64 channels, 2 power supplies, 64 relays
channel, 2 power supplies, 32 relays and the necessary rear connector CMON 5000-64-2-96 64 channels, 2 power supplies, 96 relays
boards.
Contact the Customer Service Group (CSG), SKF Condition Monitoring
Center – Lulea at CSG-Lulea@skf.com for other CMON 5000 part
numbers.
24
Ordering information – accessories / spare parts
25
The Power of Knowledge Engineering
Seals
Bearings Lubrication Drawing on five areas of competence and application-specific expertise amassed over more than 100
and units systems years, SKF brings innovative solutions to OEMs and production facilities in every major industry world-
wide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics
(combining mechanics and electronics into intelligent systems), and a wide range of services, from 3-D
Mechatronics Services
computer modelling to advanced condition monitoring and reliability and asset management systems.
A global presence provides SKF customers uniform quality standards and worldwide product availability.
Please contact:
SKF Condition Monitoring Center – Luleå
Aurorum 30, S-977 75 • Luleå, Sweden
Tel: +46 (0) 31 337 10 00 • Fax: +46 (0) 920 134 40
Web: www.skf.com/cm
® SKF, @PTITUDE, MICROLOG and MULTILOG are registered trademarks of the SKF Group.
All other trademarks are the property of their respective owners.
© SKF Group 2015
The contents of this publication are the copyright of the publisher and may not be reproduced (even
extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy
of the information contained in this publication but no liability can be accepted for any loss or damage
whether direct, indirect or consequential arising out of the use of the information contained herein.
SKF reserves the right to alter any part of this publication without prior notice.
Patents: US 4,768,380 · US 5,633,811 · US 5,679,900 · US 5,845,230 · US 5,852,351 ·
US 5,854,553 · US 5,854,994 · US 5,870,699 · US 5,907,491 · US 5,992,237 · US 6,006,164 ·
US 6,124,692 · US 6,138,078 · US 6,199,422 · US 6,202,491 · US 6,275,781 · US 6,301,514 ·
US 6,437,692 · US 6,489,884 · US 6,513,386 · US 6,633,822 · US 6,789,025 · US 6,792,360 ·
US 7,103,511 · US 7,697,492 · WO/2003/048714
skf.com