DN 15 up to DN 65 PN 40
Technical Information
Nominal size DN 15 up to DN 65, PN40
Connections flange acc. DIN EN 1092-1
flange acc. ANSI #150
flange acc. ANSI #300
Nominal pressure PN 40 / ANSI #150 / ANSI #300
Max. fluid temperature:
with metal bonnet -30°C up to +200°C
with plastic bonnet -30°C up to +135°C
with diaphragm actuator -30°C up to +200°C
Ambient temperature -30°C up to +60°C Options
Viscosity of the fluid maximum 600 mm²/s (600cSt, 80°E) e.g.:
Vacuum maximum 0,001 bar abs - limit switches
See tables and diagramms,limitation for • inductive proximity switch
• elektrical switches
dangerous gases acc. Pressure equipment
Working pressure • pneumatic switches
directive 2014/68/EU (category I): - pilot valves
PS x DN < 1000 - manual override
Working pressure for maximum 12 bar - oil and grease free version
packing underneath - PTFE free version
Leakage acc. EN 12266-1 leakage class A - ASI-Bus
*: Please consider further temperature versions and limits in
technical bulletin 32
removable position
indicator
versatile bonnet (pilot
pressure connection) bonnet material brass chrome
direct pressure control (with a plated, plastic, stainless steel
pilot valve if rquired) actuation (Ø 50 mm/80 mm)
by air, water, mineral oil and aluminium, corrosion protected
other media ( Ø 125 mm)
exterior lip sealing
leak detector
piston rod, stainless
head section steel 1.4571, „roller burnished“
normally
closed
Schubert & Salzer Control Systems GmbH, Bunsenstr. 38, 85051 Ingolstadt, Tel: +49 (0)841-9654 0, Fax: +49 (0)841 9654 590
info.cs@schubert-salzer.com, www.schubert-salzer.com
Angle Bodied Flange Valve 7031
standard design
Spring closed NC (closing with flow) Spring opens NO (closing against flow)
Normally closed angled bodied flange valves, closing with the Normally open angled bodied flanged valves, closing
flow. Operates better with gases, with liquids water hammer against the flow
is possible.
35
D50 DN20 35
30
30
DN25
25 25
20 20
DN25
DN32
15 15
upper limit for ANSI #150 Upper limit for ANSI #150
DN40
DN32
10 10
DN40
5 5
DN50
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 10
pilot pressure [bar] Pilot pressure [bar]
TYPE 7031-NC-with flow TYPE 7031-NO-against flow
maximum pilot pressure 1 bar more than necessary pilot pressure for working
pressure
D80
working pressure [bar]
DN32 DN32
35 DN25
35 DN25
30
30
25 25 DN40
DN40
20 20
15 15
DN50 Upper limit for ANSI #150 DN50
upper limit for ANSI #150 DN65
10 DN80
10
DN65
5 5
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 10
pilot pressure [bar] Pilot pressure [bar]
TYPE 7031-NC-with flow TYPE 7031-NO-against flow
maximum pilot pressure 0,8 bar more than necessary pilot pressure for
working pressure
D125
working pressure [bar]
DN32 DN32
35 35
30 30
25 25 DN40
DN40
20 20
15 15
DN50 upper limit for ANSI #150 DN50 Upper limit for ANSI #150
DN65 DN65
10 10
DN80
5 5
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 10
pilot pressure [bar] Pilot pressure [bar]
TYPE 7031-NC-with flow TYPE 7031-NO-against flow
maximum pilot pressure 0,5 bar more than necessary pilot pressure for
working pressure
2/7
Angle Bodied Flanged Valve 7031
standard design
Nominal Working pressure Pilot Piston Springs Nominal Working pressure Pilot Piston Springs
size (i.e. differential) pressure Ø size (i.e. differential) pressure Ø
bar bar mm bar bar mm
DN15 22 3,5 - 10 50 1 DN40 1,9 4,5 - 10 50 2
DN20 7 3,5 - 10 50 1 DN40 3,3 5,7 - 10 50 3
DN20 13 4,5 - 10 50 2 DN40 7 3,5 - 10 80 1
DN20 19 5,7 - 10 50 3 DN40 10 4,4 - 10 80 2
DN25 2,5 3,5 - 10 50 1 DN40 13 5,6 - 10 80 3
DN25 5,8 4,5 - 10 50 2 DN40 7 1,3 - 10 125 1
DN25 9 5,7 - 10 50 3 DN40 15 2,2 - 10 125 2
DN25 22 3,5 - 10 80 1 DN40 21 3,1 - 10 125 3
DN32 1,1 3,5 - 10 50 1 DN50 4 3,5 - 10 80 1
DN32 3,1 4,5 - 10 50 2 DN50 6 4,4 - 10 80 2
DN32 5,2 5,7 - 10 50 3 DN50 7,5 5,6 - 10 80 3
DN32 12 3,5 - 10 80 1 DN50 8,5 2,2 - 10 125 2
DN32 17 4,4 - 10 80 2 DN50 13 3,1 - 10 125 3
DN32 22 5,6 - 10 80 3 DN65 4 5,6 - 10 80 3
DN32 11 1,3 - 10 125 1 DN65 5 2,2 - 10 125 2
DN32 23 2,2 - 10 125 2 DN65 7 3,1 - 10 125 3
Standard
3/7
Angle Bodied Flanged Valve 7031
reinforced design
Spring closed NC (closing with flow) Spring opens NO (closing against flow)
Normally closed angled bodied flange valves, closing with Normally open angled bodied flanged valves, closing
the flow. Operates better with gases, with liquids water against the flow
hammer is possible.
D125 35
35
30 30
DN50
25 25
DN50
20 20
DN65 DN65
15 15
upper limit for ANSI #150 Obergrenze für ANSI #150
DN80
10 10
5 5
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 10
TYP 7010-NC-with flow-reinforced pilot pressure [bar] pilot pressure [bar]
TYPE 7031-NO-against flow -reinforced
maximum pilot pressure 0,5 bar more than necessary pilot pressure for
working pressure
40
working pressure [bar]
D250 35
D125
35
PEEK
30 30
DN50 DN50
25 25
20 20
DN65
DN65
15 15
upper limit for ANSI #150 Upper limit for ANSI #150
10 10 DN80
5 5
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
TYPE 7010-NC-with flow-reinforced pilot pressure [bar] pilot pressure [bar]
TYPE 7010-NO-against flow-reinforced
maximum pilot pressure 0,5 bar more than necessary pilot pressure for
working pressure
35
D250
PEEK
30
DN50
25
20
DN65
15
DN80 Upper limit for ANSI #150
10
0
0 1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12
7 0 3 1 / V S 1 - 6 : Please quote all 6 sections.
7 - 12: Quote only if required.
Symbol: "V": Valve
Type Size "A": Actuator (valve without body)
"R": Repair kit (sealings)
1. Body type 2. Connection 3. Body material 4. Seating seal 5. Pilot function 6. Actuator
2 angle body 9 angle bodied 2 stainless steel 0 PTFE 0 NC (closing with flow) 0 piston Ø50mm
flanged valve flange valve DIN 1.4408
EN 1092-1
1 FKM (Viton) 1 NO (closing against flow) 1 piston Ø80mm
C dto. ANSI #150
F dto. ANSI #300 2 EPDM 2 NC (closing against flow) 2 piston Ø125mm
C diaphragm Ø250mm
3 NBR 3 Universal, double acting K plastic bonnet for
piston Ø50mm
M plastic bonnet for
piston Ø80mm
7. Springs 8. Head section 9. Packing 10. Temperature 11. Accessories 12. Special versions
material version
- standard - standard - standard - standard - no accessories S special versions
1 1 spring 2 packing H high temperature 1 electrical position indicator M position indicator with
underneath version with one switch cable bushing
2 2 springs K reinforced 2 electrical position indicator N position indicator with
design with two switches plug connection
5/7
Angle Bodied Flanged Valve 7031
H
D
F
45°
1.4
40
K 8
B
C
A
6/7
Angle Bodied Flanged Valve 7031
reinforced design
Dimensions and Weights
F
G
C
B
SW1 A
1.4408
L
45°
Text and pictures are not binding. We reserve the right, to alter the equipment.