Patient Monitoring Solutions

www.axcentmedical.com
For Out-Patient Department, Spot-check, Transport,
Ward and other Basic Monitoring.

Configuration Optional

Masimo/Nellcor SpO2, Quick Temp,


SpO2 + NIBP, Li-ion battery
Barcode scanner

SpO2+NIBP+ECG+TEMP, Masimo/Nellcor SpO2, EtCO2, Quick Temp,


Li-ion battery Barcode scanner, Thermal Recorder

Technical Specifications

Display RESP
8” color TFT LCD Screen, resolution: 800 x 600 Measurement method: Thoracic electrical
bioimpedance
ECG Measuring lead: Lead I, II
Lead type Wave gain: ×0.25, ×0.5, ×1, ×2
3-lead: I, II, III Respiratory impedance range: 0.5-5 Ω
5-lead: I, II, III, aVR, aVL, aVF, V Baseline impedance: 500-4000 Ω
Display sensitivity: Gain: 10 grades
2.5 mm/mV (×0.25), 5 mm/mV (×0.5), Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
PAVO Vital Sign Monitor 10 mm/mV (×1.0), 20 mm/mV (×2.0)
Wave sweep speed: 6.25 mm/s, 12.5 mm/s, TEMP
25 mm/s, 50 mm/s Measurement method: Thermistor
Features Bandwidth Measuring range: 5~50 °C (41~122 °F)
• 8” color TFT LCD Screen (touch screen optional) Diagnostic mode: 0.05Hz~100Hz Resolution: 0.1 °C
• Portable, lightweight and sturdy design Monitor mode: 0.5Hz~40Hz Measurement accuracy: ±0.1 °C
• Flexible parameters configuration for different clinical environments Surgery mode: 1Hz~20Hz
Strong filter mode: 5Hz~20Hz CMRR Recorder (optional)
• Rechargeable Li-ion Battery (up to 12 hours uninterruptable work)
>100dB Built-in, Thermal dot array
• Big font and font color display setting
Notch: 50/60 Hz notch filter can be set to Horizontal resolution: 16 dots/mm (25 mm/s
• Spot-check and continuous monitoring mode paper speed)
on or off
• Selectable for Adult, Pediatric and Neonatal patients Differential input impedance >5 MΩ Vertical resolution: 8 dots/mm
• Wired/Wireless CMS, support HL7 protocol to HIS Electrode polarization voltage range: ±400 mV Paper speed: 25 mm/s, 50 mm/s
• Barcode scanner support Baseline recovery time <3 s after defibrillation Number of waveform channels: 3
• Thermal recorder support (in monitor and surgery mode)
• Graphical & tabular trend review Calibration signal: 1 mV (peak - peak),
• 48 hours holographic wave review for each patient (stored in SD card) accuracy ±3%

www.axcentmedical.com
PAVO Vital Sign Monitor
Technical Specifications

NIBP Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120,


Measurement method: Automatic 180, 240, 480 minutes
oscillometric method Overpressure protection: Software and
Operating mode: Manual, automatic, hardware, double safety protection
continuous Cuff pressure range: 0-280 mmHg
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20~40 s Standard SpO2 Infrared Ear Thermometer (optional) Phasein IRMA™ Sidestream CO2 (optional)
Measurement type: Systolic, Diastolic, Mean Measurement range: 0-100% Displayed range: 34~42.2 °C (93.2~108 F°) Warm-up time: Full accuracy within
Measurement range (mmHg) Resolution: 1% Operation ambient temperature range: 10 seconds
Range of Systolic pressure: Adult 40-270 Accuracy: ±2% (70-100%, Adult/Pediatric); 10~40 °C (50~104 °F) Sampling flow rate: 50 ml/min (+/-10/min)
Pediatric 40-230 ±3% (70-100%, Neonate); Accuracy for displayed temperature range: Accuracy: ± (0.2% +2% of the reading)
Neonatal 40-135 0-69%, unspecified ≥35 °C (95.9 °F) ~ ≤42.2 °C (107.6 °F) range Measurement Range: 0 -15%
Range of Diastolic pressure: Adult 10-210 Refreshing Rate: 1s ±0.2 °C (0.4 °F) Rise time: 200 ms, typical at 50 ml/min
Pediatric 10-150 <35 °C (95.9 °F) ~ ≥34 °C (93.2 °F) range flow rate
Masimo SpO2 (optional)
Neonatal 10-100 ±0.3 °C (0.5 °F) Total response time: within 3 seconds
Measurement range: 0-100%
Range of Mean pressure: Adult 20-230 (with 2m Momoline sampling line)
Resolution: 1%
Pediatric 20-165 AWRR Range: 0-150 bpm
Accuracy: ±2% (70-100%, Adult/Pediatric),
Neonatal 20-110 AWRR Accuracy: ±1 breath
non-motion, low
Measurement accuracy
±3% (70-100%, Neonate, Phasein IRMA™ Mainstream CO2 (optional)
Maximum average error: ±5 mmHg
non-motion); Measurement Range: 0-15%
Maximum standard deviation: 8 mmHg
±3% (70-100%, motion); Warm-up time: Full accuracy within
Resolution: 1 mmHg
0-69%, unspecified 10 seconds
Refreshing Rate: 1s Accuracy: ± (0.2% +2% of the reading)
AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath

Operation Environment
Power: AC 100-250 V, 50/60 Hz
Temperature: 0-40 °C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate

Portable Design Touch Screen Quick Temp


(Optional) (Infrared Ear Thermometer)

www.axcentmedical.com
12.1”color TFT LCD screen, wide and flat screen design,ecnomic and reliable

Configuration: ECG+SpO2+NIBP+2TEMP+PR+RESP, Li-ion battery


Optional: Touch-Screen, 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-Gas, BIS,
NMT, VGA, Thermal Recorder, Wired/Wireless CMS

Technical Specifications

Display RESP
12.1” TFT (touch screen optional) Measurement method: Thoracic electrical
Resolution: 800 x 600 bioimpedance
Number of traces: 8 waveforms Measuring lead: Lead I, II
Wave gain: ×0.25, ×0.5, ×1, ×2
ECG Respiratory impedance range: 0.5-5Ω
Lead type: 3-lead, 5-lead, 12-lead Baseline impedance: 500-4000Ω
ECG waveform: 2 channels, 7 channels, Gain: 10 grades
12 channels Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Display sensitivity: 2.5 mm/mV (×0.25),
5 mm/mV (×0.5), 10 mm/mV (×1.0), Pulse Rate
20 mm/mV (×2.0) Range: 30~254 bpm
Wave sweep speed: 6.25 mm/s, 12.5 mm/s, Resolution: 1bpm
25 mm/s, 50 mm/s Accuracy: ±2bpm (non-motion)
Bandwidth ±5bpm (motion)
CETUS x12 Patient Monitor Diagnostic mode: 0.05 Hz~100 Hz Refreshing rate: 1s
Monitor mode: 0.5 Hz~40 Hz
Surgery mode: 1Hz~20Hz TEMP
Features Strong filter mode: 5 Hz~20 Hz Accuracy: ±0.1 °C or ±0.2 °C °F (without probe)
CMRR >100 dB Measurement range: 5~50 °C (41~122 °F)
• 12.1” color TFT LCD screen
Notch: 50/60 Hz notch filter can be set to Channel: Two channels
• 8 waveform display, up to 12-lead ECG analysis
on or off Resolution: 0.1 °C
• Powerful calculation
Differential input impedance >5MΩ Parameters: T1,T2 and TD
(Hemodynamic, Drug Dose, Oxygenation, Ventilation)
Electrode polarization voltage range: ±400 mV
• Pacemaker detection Baseline recovery time <3s after defibrillation
• ST & arrhythmia analysis (in monitor and surgery mode)
• OxyCRGs screen Calibration signal: 1mV (peak - peak),
• Wired/Wireless CMS, support HL7 protocol to HIS accuracy ±3%
• SpO2 pulse-tone modulation (Pitch Tone)
• MEWS (Modified Early Warning Score)
• Graphical & tabular trend review (120 hours)
• Rechargeable Lithium-Ion Battery (2600 mAh)

www.axcentmedical.com
7-lead ECG
CETUS x12 Patient Monitor
Technical Specifications

NIBP Overpressure protection: Software and


Measurement method: Automatic oscillome- hardware, double safety protection
tric method Cuff pressure range: 0-280 mmHg
Operating mode: Manual, automatic,
continuous SpO2
Measurement unit: mmHg/kPa selectable Measurement range: 0-100%
Typical measurement time: 20~40 s Resolution: 1%
Measurement type: Systolic, Diastolic, Mean Accuracy: ±
 2% (70-100%, Adult/Pediatric);
Measurement range (mmHg) ±3% (70-100%, Neonate);
Range of Systolic pressure: Adult 40-270 0-69%, unspecified
Pediatric 40-200 Refreshing Rate: 1s
Neonatal 40-135
Masimo SET® SpO2 (Optional)
Range of Diastolic pressure: Adult 10-210
Measurement range: 0-100%
Pediatric 10-150
Resolution: 1%
Neonatal 10-95
Accuracy: ±2% (70-100%, Adult/Pediatric,
Range of Mean pressure: Adult 20-230
non-motion, low prefusion);
Pediatric 20-165
±3% (70-100%, Neonate,
Neonatal 20-105
Measurement accuracy non-motion); CETUS x15
±3% (70-100%, motion);
Maximum average error: ±5 mmHg Critical Care Patient Monitor
0-69%, unspecified
Maximum standard deviation: 8 mmHg
Refreshing Rate: 1s Features
Resolution: 1 mmHg
Interval: 1, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, • 15.6” High resolution TFT LCD Touch screen
Recorder (Optional)
240, 480 minutes • 10 waveform display, up to 12-lead ECG analysis
Built-in, Thermal dot array
• Powerful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation)
Horizontal resolution: 16 dots/mm (25 mm/s
paper speed) • Pacemaker detection
Vertical resolution: 8 dots/mm • ST & arrhythmia analysis
Paper speed: 25 mm/s, 50 mm/s • SpO2 support PVI and PI, low perfusion 0.2%
Number of waveform channels: 3 • Aspect BISx module, NMT (Organon TOF-Watch®) module optional
•W
 ired/Wireless CMS, support HL7 protocol to HIS
Operation Environment
•S
 pO2 pulse-tone modulation (Pitch Tone)
Power: AC 100-250V, 50/60Hz
•V
 GA support external display
Temperature: 5-40 °C
• Graphical & tabular trend review (120 hours)
Humidity: <80%
Patient Range: Adult, Pediatric, Neonate •4
 8 hours full disclosure wave review for each patient
(stored in SD card)
www.axcentmedical.com
CETUS x15 Critical Care Patient Monitor
Multiple parameter options satisfy the need for ICU, CCU, NICU. Technical Specifications

Configuration: 5-lead ECG, SpO2, NIBP, TEMP, Resp, PR; Li-ion battery Notch: 50/60 Hz notch filter can be set Masimo SET® SpO2(Optional)
Optional: Touch-Screen, 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-Gas, BIS, NMT, to on or off Measurement range: 0-100%
VGA, Thermal Recorder, Wired/Wireless CMS Differential input impedance >5MΩ Resolution: 1%
Electrode polarization voltage range: ±400mV Accuracy: ±2% (70-100%, Adult/Pediatric,
Baseline recovery time <3s after defibrillation non-motion, low prefusion);
Masimo SET® SpO2 Bispectrial Index™ by Aspect
Provides anti-motion and anti-low Monitor the level of consciousness (in monitor and surgery mode) ±3% (70-100%, Neonate,
perfusion SpO2 measurement. of the patient under general anesthesia
or sedation. provides BIS, SQI, EMG, SR, Calibration signal: 1 mV (peak - peak), non-motion); 
SEF, TP, PC value and EEG wave. accuracy ±3% ±3% (70-100%, motion); 0-69%,
unspecified
Masimo Phasein IRMATM/ISA NMT RESP Refreshing Rate: 1s
Sidestream/Mainstream EtCO2 Intergrade Organon TOF-Watch® SX
Allows selection of the modality best Measurement method: Thoracic electrical
suited to the application, monitoring bioimpedance Pulse Rate
with infrared absorption technique.
Measuring lead: Lead I, II Range: 30~300 bpm
Wave gain: ×0.25, ×0.5, ×1, ×2 Resolution: 1 bpm
IBP C.O.
2-4 Channel, support IBP waveform Cardiac Output Respiratory impedance range: 0.5-5 Ω Accuracy: ±2bpm (non-motion)
overlapping display
Baseline impedance: 500-4000 Ω ±5bpm (motion)
Gain: 10 grades Refreshing rate: 1s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
NIBP
Technical Specifications TEMP Measurement method: Automatic
Accuracy: ±0.1 or ±0.2 °F (without probe) oscillometric method
Display ECG Measurement range: 5~50℃ (41~122 °F) Operating mode: Manual, automatic,
15.6” TFT (touch screen optional) Lead type: 3-lead, 5-lead,12-lead Channel: Two channels continuous
Resolution: 1366 x 768 ECG waveform: 2 channels, 7 channels, Resolution: 0.1℃ Measurement unit: mmHg/kPa selectable
Number of traces: 12 waveforms 12 channels Parameters::T1, T2 and TD Typical measurement time: 20~40 s
Display sensitivity: 2.5 mm/mV (×0.25), Measurement type: Systolic, Diastolic,
I/O 5 mm/mV (×0.5), 10 mm/mV (×1.0), SpO2 Mean Measurement range (mmHg)
LAN: 1 standard RJ45 port 20 mm/mV (×2.0) Measurement range: 0-100% Range of Systolic pressure: Adult 40-270
WLAN: IEEE 802.11b/g/n Wave sweep speed: 6.25 mm/s, 12.5 mm/s, Resolution: 1% Pediatric 40-200
USB: 2 USB connectors 25 mm/s, 50 mm/s Accuracy: ±2% (70-100%, Adult/Pediatric); Neonatal 40-135
SD: 1 SD card socket Bandwidth ±3% (70-100%, Neonate); Range of Diastolic pressure: Adult 10-210
VGA: 1 VGA monitor connector Diagnostic mode: 0.05 Hz~100 Hz 0-69%, unspecified Pediatric 10-150
Output: 1 connector for Nurse call, Monitor mode: 0.5 Hz~40 Hz Refreshing Rate: 1s Neonatal 10-95
Defib Sync Analog Output Surgery mode: 1 Hz~20 Hz
Strong filter mode: 5Hz~20 Hz
CMRR>100 dB

www.axcentmedical.com
CETUS x15 Critical Care Patient Monitor
Technical Specifications

Range of Mean pressure: Adult 20-230 Standard Mainstream CO2 (Optional)


Pediatric 20-165 Measurement range: 0-19.7%, 150 mmHg,
Neonatal 20-105 or 0-20 kPa
12-lead ECG 4 channel IBP
Measurement accuracy Resolution: 0.1 mmHg
Maximum average error: ±5 mmHg Measurement accuracy
Maximum standard deviation: 8 mmHg 0-40 mmHg: ± 2 mmHg
Resolution: 1 mmHg 41-70 mmHg: ± 5% of reading
Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 71-100 mmHg: ± 8% of reading
180, 240, 480 minutes 101-150 mmHg: ± 10% of reading
Overpressure protection: Software and Respiration rate: 3-150 bpm
hardware, double safety protection Respiration rate accuracy: 1 ±1bpm
Cuff pressure range: 0-280 mmHg Warm-up time: 97% within 8 s, OxyCRG screen Dynamic trends

full accuracy within 20 s


IBP (Optional)
Channel: 2-channel or 4-channel Standard Sidestream CO2 (Optional) Phasein ISA Sidestream CO2 (Optional) Phasein IRMA™ AX+ Mainstream Multi-gas
ART: 0 to 300 mmHg Measurement rage: 0-20% (0-150 mmHg) Warm-up time: Full accuracy within (Optional)
PA: -6 to 120 mmHg Accuracy: < 5.0% CO 2: ± 2 mmHg 10 seconds Gas: CO2, N2O, HAL, ISO, ENF, SEV, DES with
CVP/RAP/LAP/ICP: -10 to 40 mmHg > 5.0% CO 2: < 6% of reading Sampling flow rate: 50ml/min(+/-10/min) automatic identification
Measurement range: P1/P2 -50 to 300 mmHg Respiration rate: 2~150 BPM Measurement Range: 0-25% Warm-up time: Full accuracy within
Resolution: 1mmHg Respiration rate accuracy: 1% ±1BPM Accuracy: 0~15% (±0.2% of the reading) 20 seconds for IRMA
Accuracy: ±2% or ±1mmHg, Warm-up time: 97% within 45 s, full accuracy 15~25%, unspecified AX+ CO2 Accuracy:
whichever is greater (without sensor) within 10 min. Rise time: 200 ms, typical at 50 ml/min 0-10%: ± (0.2%+2% of the reading)
Sensitivity: 5uV/mmHg/V Rise times (t 10-90%): About 100 ms, flow rate 0-15%: ± (0.3%+2% of the reading)
Impedance range: 300 to 3000 Ω when flow is 100 ml/min, adult water trap, Total response time: within 3 seconds N2O Accuracy:
1.5 m sampling tube (with 2 m Momoline sampling line) 0-100%: ± (2%+2% of the reading)
C.O. (Optional) Delay time: <3 sec when flow is 100 ml/min, AWRR Range: 0-150 bpm HAL, ISO, ENF:
Method: Thermodilution adult water trap, 1.5 m sampling tube AWRR Accuracy: ±1 breath 0-8%: ± (0.15%+5% of the reading)
Range: C.O.: 0.2 to 20 L/min SEV:0-10%: ± (0.15%+5% of the reading)
TB: 23 to 45 ℃ Recorder (Optional) Phasein IRMA™ Mainstream CO2 (Optional) DES:0-22%: ± (0.15%+5% of the reading)
T1: -1 to 27℃ Built-in, Thermal dot array Measurement Range: 0-25% Agent identification time: <20 s (typical <10 s)
Accuracy: C.O.: ±5% or ±0.1L/min, Horizontal resolution: 16 dots/mm Accuracy: 0~15% (±0.2% of the reading) AWRR range: 0-150 bpm
whichever is greater (25 mm/s paper speed) 15~25%, unspecified AWRR accuracy: +/-1bpm
TB, T1:±0.5℃ (without sensor) Vertical resolution: 8 dots/mm Warm-up time: Full accuracy within ‚ Apnea time: 20~60 s
Paper speed: 25 mm/s, 50 mm/s 10 seconds
Number of waveform channels: 3 AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath

www.axcentmedical.com
CETUS x15 Critical Care Patient Monitor
Technical Specifications

Aspect BISx module (Optional) Acceleration transducer: Accuracy ±5% of full


Parameter Measurement: scale value
BC: 0~30 (Only limited to the combined use Temperature sensor: Range 20.0-41.5°C
of an external sensor with a BIS module) (accuracy ±5 °C)
EMG: 30~55 dB (bar chart) with intensity
between 30 dB and 80 dB (tendency chart) Operation Environment
BIS: 0~100 Power: AC 100-250 V, 50/60 Hz
SQI: 0%~100% Temperature: 5-40 °C
SR: 0%~100% Humidity: <80%
SEF: 0.5 Hz~30 Hz Patient Range: Adult, Pediatric, Neonate
TP: 40~100 Db
EEG Measurement:
Input impedance >5 MΩ
Noise (RTI) <2 μV (0.25~50 Hz)
Input signal range: ±1 Mv
EEG bandwidth between: 0.25 Hz~110 Hz

NMT Tof-Watch® SX (Optional)


Microprocessor-controlled
Stimulation Mode: TOF, TOFS, PTC,
1 Hz Twitch, 0.1 Hz Twitch, DBS DBS3.3 and
3.2 (Double Burst), Tetanic Stimulation (Burst),
5s – 50 Hz or 100 Hz
Output (accuracy ±5% of full scale value)
Surface electrodes:
Constant current, 0-60 mA (0-12/18μC)
up to 5 KOhm.
Monophasic, 200 μs or 300 μs pulse width
Needle electrodes:
Constant current,0-6 mA (0-0.24 μC)
up to 5 KOhm.
Monophasic, 40 μs pulse width

www.axcentmedical.com
CETUS xl Advanced Patient Monitor
Multiple parameter options satisfy the needs of ICU, CCU, NICU

Configuration: 5-lead ECG, SpO2, NIBP, Resp, PR; Li-ion battery


Optional: 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-gas, BIS, NMT;
VGA, Thermal Recorder, Wired/Wireless CMS

Masimo SET® SpO2 Bispectrial Index™ by Aspect


Provides anti-motion and anti-low Monitor the level of consciousness
perfusion SpO2 measurement. of the patient under general anesthesia
or sedation. provides BIS, SQI, EMG, SR,
SEF, TP, PC value and EEG wave.

Masimo Phasein IRMA™/ISA NMT


Sidestream/Mainstream EtCO2 Intergrade Organon TOF-Watch® SX
Allows selection of the modality best
suited to the application, monitoring
with infrared absorption technique.

IBP C.O.
2-4 Channel, support IBP waveform Cardiac Output
overlapping display

CETUS xl Advanced Patient Monitor Technical Specifications

Display ECG
Features 15.6” TFT Touch screen Lead type: 3-lead, 5-lead,12-lead
• 15.6”/17/19” switchable TFT LCD Touch Screen Resolution: 1366 x 768 ECG waveform: 2 channels, 7 channels,
• Aluminium material shell Number of traces: 12 waveforms 12 channels
Display sensitivity: 2.5 mm/mV (×0.25),
• Fanless design suitable for quite care environment
I/O 5 mm/mV (×0.5), 10 mm/mV (×1.0),
• 10 waveform display, up to 12-lead ECG analysis LAN: 1 standard RJ45 port 20 mm/mV (×2.0)
• Powerful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation) WLAN: IEEE 802.11b/g/n Wave sweep speed: 6.25mm/s, 12.5 mm/s,
• SpO2 support PVI and PI, low perfusion 0.2% USB: 2 USB connectors 25 mm/s, 50 mm/s
• Aspect module, NMT (Organon TOF-Watch®) module optional SD: 1 SD card socket Bandwidth
• Wired/Wireless CMS, support HL7 protocol to HIS VGA: 1 VGA monitor connector Diagnostic mode: 0.05 Hz~100 Hz
• SpO2 pulse-tone modulation (Pitch Tone) Output: 1 connector for Nurse call, Monitor mode: 0.5 Hz~40 Hz
Defib Sync Analog Output Surgery mode: 1 Hz~20 Hz
• VGA support external display
• Graphical & tabular trend review (120 hours) Strong filter mode: 5Hz~20 Hz

•4
 8 h full disclosure wave review for each patient (stored in SD card)

www.axcentmedical.com
12-lead ECG OxyCRG screen

CETUS xl Advanced Patient Monitor


Technical Specifications

CMRR>100dB SpO2
Notch: 50/60Hz notch filter can be set to Measurement range: 0-100%
on or off Resolution: 1%
Differential input impedance >5 MΩ Accuracy: ±2% (70-100%, Adult/Pediatric);
4 channel IBP Dynamic trends
Electrode polarization voltage range: ±400 mV ±3% (70-100%, Neonate);
Baseline recovery time <3s after defibrillation 0-69%, unspecified
(in monitor and surgery mode) Refreshing Rate: 1s NIBP IBP (Optional)
Calibration signal: 1 mV (peak - peak), Measurement method: Automatic Channel: 2-channel or 4-channel
accuracy ±3% Masimo SET® SpO2(Optional) oscillometric method ART: 0 to 300 mmHg
Measurement range: 0-100% Operating mode: Manual, automatic, PA: -6 to 120 mmHg
RESP Resolution: 1% continuous CVP/RAP/LAP/ICP: -10 to 40 mmHg
Measurement method: Thoracic electrical Accuracy: ±2% (70-100%, Adult/Pediatric, Measurement unit: mmHg/kPa selectable Measurement range: P1/P2 -50 to 300 mmHg
bioimpedance non-motion, low prefusion); Typical measurement time: 20~40s Resolution: 1 mmHg
Measuring lead: Lead I, II ±3% (70-100%, Neonate, Measurement type: Systolic, Diastolic, Mean Accuracy: ±2% or ±1 mmHg,
Wave gain: ×0.25, ×0.5, ×1, ×2 non-motion); Measurement range (mmHg) whichever is greater (without sensor)
Respiratory impedance range: 0.5-5 Ω ±3% (70-100%, motion); Range of Systolic pressure: Adult 40-270 Sensitivity: 5uV/mmHg/V
Baseline impedance: 500-4000 Ω 0-69%, unspecified Pediatric 40-200 Impedance range: 300 to 3000 Ω
Gain: 10 grades Refreshing Rate: 1s Neonatal 40-135
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s Range of Diastolic pressure: Adult 10-210 C.O. (Optional)
Pulse Rate Method: Thermodilution
Pediatric 10-150
TEMP Range: 30~300 bpm Range: C.O.: 0.2 to 20 L/min
Neonatal 10-95
Accuracy: ±0.1 °C or ±0.2 °F (without probe) Resolution: 1bpm TB: 23 to 45 °C
Range of Mean pressure: Adult 20-230
Measurement range: 5~50 °C (41~122 °F) Accuracy: ±2bpm (non-motion) T1: -1 to 27 °C
Pediatric 20-165
Channel: Two channels ±5bpm (motion) Accuracy: C.O.: ±5% or ±0.1L/min,
Neonatal 20-105
Resolution: 0.1 °C Refreshing rate: 1s whichever is greater TB, T1: ±0.5°C
Measurement accuracy
Parameters: T1, T2 and TD (without sensor)
Maximum average error: ±5 mmHg
Maximum standard deviation: 8 mmHg
Resolution: 1 mmHg
Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180,
240, 480 minutes
Overpressure protection: Software and
hardware, double safety protection
Cuff pressure range: 0-280mmHg

www.axcentmedical.com
CETUS xl Advanced Patient Monitor
Technical Specifications

Standard Mainstream CO2 (Optional) Phasein ISA Sidestream CO2 (Optional)


Measurement range: 0-19.7%, Warm-up time: Full accuracy within 10 se-
150 mmHg, or 0-20kPa conds
Resolution: 0.1 mmHg Sampling flow rate: 50ml/min(+/-10/min)
Vivid visualized icons ... Engineered for the most impressive operation
Measurement accuracy Measurement Range: 0 -25%
0 - 40 mmHg: ± 2 mmHg Accuracy: 0~15% (±0.2% of the reading)
41 - 70 mmHg: ± 5% of reading 15~25%, unspecified SEV:0-10%: ± (0.15%+5% of the reading) NMT Tof-Watch® SX (Optional)
71 - 100 mmHg: ± 8% of reading Rise time: 200 ms, typical at 50 ml/min DES:0-22%: ± (0.15%+5% of the reading) Microprocessor-controlled
101 - 150 mmHg: ± 10% of reading flow rate Agent identification time: <20s(typical <10s) Stimulation Mode: TOF, TOFS, PTC, 1Hz
Respiration rate: 3-150 bpm Total response time: within 3 seconds AWRR range: 0-150 bpm Twitch, 0.1Hz
Respiration rate accuracy: 1% ±1 bpm (with 2 m Momoline sampling line) AWRR accuracy: +/-1 bpm Twitch, DBS DBS3.3 and 3.2 (Double Burst),
Warm-up time: 97% within 8s, full accuracy AWRR Range: 0-150 bpm Apnea time: 20~60s Tetanic Stimulation (Burst), 5s – 50 Hz or
within 20s AWRR Accuracy: ±1 breath 100 Hz
Aspect BISx module (Optional) Output (accuracy ±5% of full scale value)
Standard Sidestream CO2 (Optional) Phasein IRMA™ Mainstream CO2 (Optional) Parameter Measurement: Surface electrodes:
Measurement rage: 0-20% (0-150 mmHg) Measurement Range: 0 -25% BC: 0~30 (Only limited to the combined use of Constant current,0-60mA(0-12/18μC) up to
Accuracy: < 5.0% CO 2: ± 2 mmHg Accuracy: 0~15% (±0.2% of the reading) an external sensor with a BIS module) 5 KOhm.
> 5.0% CO 2: < 6% of reading 15~25%, unspecified EMG: 30~55dB (bar chart) with intensity Monophasic, 200 μs or 300 μs pulse width
Respiration rate: 2~150 BPM Warm-up time: Full accuracy within between 30dB and 80dB (tendency chart) Needle electrodes:
Respiration rate accuracy: 1% ±1BPM 10 seconds BIS: 0~100 Constant current, 0-6 mA (0-0.24 μC) up to
Warm-up time: 97% within 45s, full accuracy AWRR Range: 0-150 bpm SQI: 0%~100% 5 KOhm.
within 10 min AWRR Accuracy: ±1 breath SR: 0%~100% Monophasic, 40μs pulse width
Rise times (t10-90%): About 100 ms, when SEF: 0.5 Hz~30Hz Acceleration transducer: Accuracy ±5% of full
flow is 100 ml/min, adult water trap,1.5m Phasein IRMA™ AX+ Mainstream Multi-gas TP:40~100 Db scale value
sampling tube (Optional) EEG Measurement: Input impedance >5 MΩ Temperature sensor: Range 20.0-41.5 °C
Delay time: <3sec when flow is 100 ml/min, Gas: CO2, N2O, HAL, ISO, ENF, SEV, DES with Noise (RTI) <2μV (0.25~50 Hz) (accuracy ±5 °C)
adult water trap,1.5 m sampling tube automatic identification Input signal range: ±1 Mv
Warm-up time: Full accuracy within EEG bandwidth between: 0.25 Hz~110 Hz Operation Environment
Recorder (Optional) 20 seconds for IRMA AX+ Power: AC 100-250 V, 50/60 Hz
Built-in, Thermal dot array CO2 Accuracy:  Temperature: 5-40 °C
Horizontal resolution: 16 dots/mm (25 mm/s 0-10%: ± (0.2%+2% of the reading) Humidity: <80%
paper speed) 0-15%: ± (0.3%+2% of the reading) Patient Range: Adult, Pediatric, Neonate
Vertical resolution: 8 dots/mm N2O Accuracy:
Paper speed: 25 mm/s, 50 mm/s 0-100%: ± (2%+2% of the reading)
Number of waveform channels: 3 HAL, ISO, ENF:
0-8%: ± (0.15%+5% of the reading)

www.axcentmedical.com
Patient Monitoring Solutions
For more information, please contact us.

aXcent medical GmbH


Josef-Görres-Platz 2
56068 Koblenz
Germany
Phone: +49 261 30 11 117
Fax: +49 261 30 11 111
Mail: info@axcentmedical.com

www.axcentmedical.com