KL-710
Biomedical Measurement Data Acquisition System
KL-710 is a complete data acquisition system that includes both hardware and software for acquisition and
analysis of life-science data. The hardware uses the DAQ interface cards from National Instrument . As for the
software, it is written in LabVIEW. KL-710 system can use PC, Notebook, or PDA to acquire, analyze or store data.
u Features
The major software allows you to edit data and control the experiment process appearing on the screen. It performs
four general functions:
● Control the data acquisition process including the analog input, analog output, digital input, digital output, pulse
generation and trigger start.
● Perform real-time calculation including the math functions, digital filter, wave analysis, rate detection and power
spectrum.
● Perform off-line analysis including the statistics, math functions, wave analysis, rate detection and power spectrum.
● There are various types for saving data.
The software, written in LabVIEW, allows users to create their own program.
ECG_PPG ECG_PPG
u Specifications
} Module Units (KL-74001~KL-74011 & KL-74041~KL-74042)
KL-74001 General Physiological Signal (GPS) Amplifier Module
KL-74001 has one instrumentation amplifier with KI KL-74001
GENERAL PHYSIOLOGICAL
SIGNAL AMPLIFIER MODULE
Specifications:
adjustable offset and gain. It is used to amplify low-level 50/60Hz
: 30μV
Input offset voltage V OSI
2KHz
DC
Input bias current I B : 2n A
physiological signals. With a wide range of filters, it is 1KHz
200Hz
Input offset current I OS: 1n A
100Hz
0.1Hz
or 100Hz
0.05Hz
Hz or 2K Hz
.Electromyogram
Sensor Input
3-Conductor Connecting wire, 2mm EEG electrode Electrode lead Body surface Electrical conductivity jelly Position cap for EEG
electrode cable plug/10mm 3pcs (3pcs/set) electrodes
Option: For EEG
KI KL-74002
ELECTROCARDIOGRAM WILSON NETWORK
KI KL-74002A
ELECTROCARDIOGRAM
WILSON NETWORK
.Lead I
.Lead II
.Lead III
Lead I
aVL
aVF
V
aVL
aVF
V
Lead III
aVR
.aVF
Lead II Lead II
Lead I Lead I
.V
KL-74002 KL-74002A
KL-74003 IBP is used to measure direct arterial INVASIVE BLOOD PRESSURE AMPLIFIER MODULE
Specifications:
or venous blood pressure in animals for research or
Maximum input pressure : 300 mm Hg
teaching.
50/60Hz
DC
40Hz
Upper frequency response : 0.1 Hz or 1 Hz
100Hz
Lower frequency response : 40 Hz or 100 Hz
X2
Gain
X10 Notch frequency response : 50/ 60 Hz
0.1Hz
1Hz
CMRR : 85 dB minimum
Gain : 2, 10
Sensor
Input
KL-74004 can measure the indirect arterial blood pressure BLOOD PRESSURE CUFF AMPLIFIER MODULE
Specifications:
with the Korotkoff method or oscillometric method. In the X100
Maximum input pressure : 300 mm Hg
Upper frequency response : 0.3 Hz
Gain
Physiological sounds
transducer Ear phone
40Hz
LEDs : Red : 660nm
the density in the finger for using in the following application: LEDs
R_LED Infrared : 940nm
Lower frequency response : 10Hz and 40Hz
IR_LED
AC
Gain : 200
.Blood pressure waveform analysis
.Exercise physiology studies
.Psychophysiological studies Sensor
Input
10Hz
Upper frequency response : DC and 0.05 Hz
ON Lower frequency response : 1 Hz or 10 Hz
Gain : 100, 300
DC
X100
Gain
X300
0.05Hz
DC
Offset
Temperature sensor
Sensor
Input
ON
Upper frequency response : DC and 0.05 Hz
.The determination of respiration rate DC
DC
.Psychophysiological studies
Sensor
Input
Respiration transducer
Pneumotach transducer
KL-74010 Electrodermal Activity (EDA) Amplifier Module (People with cardiac pacemaker must avoid using this)
KI KL-74010
KL-74010 is a signal channel, high gain, differential amplifier ELECTRODERMALACTIVITY
AMPLIFIER MODULE
Specifications:
designed especially for measuring skin conductance. Input offset voltage VOSI : 30μV
KL-74010 measures skin conductance via the constant 1Hz
10Hz
Input bias current I B : 2n A
current technique. 0.05Hz Input offset current I OS : 1n A
Maximum input voltage : 10V
DC
Offset
Upper frequency response : DC or 0.05 Hz
is most similar to the formerly common measure of Galvanic Lower frequency response : 1 Hz or 10 Hz
Skin Resistance (GSR). KL-74010 is designed for following CMRR : 100 dB minimum
applications: Gain : 5000
.General eccrine activity measurement
Sensor Input
Sensor
Input
Ear phone
8 differential D2 D6
Analog output AI 2 AO 1
4 differential
LED Indicator
Sampling rate : 48K S/s (aggregate)
USB Port
Resolution : 14 bits differential 1. AC power cord
LED State/Device Status
13 bits single-ended 2. Connecting wire, 2mm plug / 30cm (10pcs / set)
1. Not lit :
Device not connected Max input range : ±10V 3. Alcohol prep. pad
2. On, not blinking :
Device connected
3. Single-blink :
Analog output 4. Captured and analysis software
Number of channels : 2
Operating normally
AI 5 AI 13
AI 6 AI 14
3. Electrical conductivity jelly
AI 7 AI 15
4. Body surface electrode
AI Gnd
5. EEG electrode
6. Cup electrode cord
7. Position cap for EEG
8. T-Valve
KL-74034 Functional Connector Module (for KL-74022 use) 9. Alcohol prep. pad
KI KL-74034
10. Medical tape
FUNCTIONAL CONNECTORS
4 digital input connectors, 4 digital output connectors,
2 analog output connectors, a DC+5V output connector
D0 D4
and a NRSE input ground connector from DAQ device
D1 D5
D2 D6
D3 D7
D Gnd D Gnd
AO 0 AO Gnd
AO 1 AO Gnd
+5V D Gnd
AI Sense
KL-79106
ECG Simulator
KL-710(4CH)
KL-74002A
KL-74006A
List of Experiments
KL-74001
KL-74003
KL-74004
KL-74005
KL-74007
KL-74008
KL-74009
KL-74010
KL-74041
KL-74042
KL-74023
KL-74035
KL-74011
List of Modules