You are on page 1of 3

Contact: Norma Noriega ***CORRECTED TEST CERTIFICATE —

Element Monterrey EAR-CONTROLLED DATA – 6/14/18***


Carretera Monterrey-Saltillo 3279-B, Santa Catarin
NL 66367 Date: 6/8/2018
Monterrey, Purchase Order Number: 081812
Work Order Number EXO006-06-05-65019-2

PO: POM101795 & POM101835


Customer PO: DAMOE
Material: STAINLESS STEEL - DUPLEX 2205
Lab: 81812
Specification: FOR INFORMATION ONLY
Specimens were marked: TRAPICHE 47
Base Material / Condition: NA / NA
Shape: NA
H/N / W/O: NA / NA
Label: SPECIMEN
Specimen: 292882

CHEMICAL ANALYSIS
Element Result % Min % Max %
C = 0.016 0.000 0.030
Mn = 1.73 0.00 2.00
P = 0.023 0.000 0.030
S < 0.005 0.000 0.020
Si = 0.51 0.00 1.00
Cr = 22.0 22.0 23.0
Ni = 5.26 4.50 6.50
Mo = 3.09 3.00 3.50
N = 0.17 0.14 0.20
Cu = 0.39 0.00 NS
Fe = Balance Balance Balance
Chemical Analysis performed by Optical Emission per SOP 2.02, Revision 22
Nitrogen by Fusion per SOP 13.00, Revision 12
MATERIAL IDENTIFIED AS 2205 STAINLESS STEEL (UNS S32205 12th EDITION)

Room Temperature Tensile


Test Method ASTM E 8 - 16a
Orientation LONG-TUBE

Ultimate Tensile 0.2% Offset Yield Elongation in


Initial Wall Initial Outside Initial Area
Specimen Strength (ksi) Strength (ksi) 4D (%)
Thickness (in) Diameter (in) (sq. in)
Min Min Min
Requirements N/S N/S N/S
TRAPINCHE 47 0.0350 0.254 0.0241 121 90.5 32

Respectfully submitted
15062 Bolsa Chica, Huntington Beach, CA 92649
(714) 892-1961 ph • (714) 892-8159 fax www.element.com

**Denotes non-conforming results. ***Denotes change made from original test certificate.
The information contained in this certification represents only the material submitted and is certified only for the quantities tested. Reproduction
except in full is reserved pending written approval. The recording of false, fictitious, or fraudulent statements or entries on the certificate may be
punishable as a felony under federal law. All testing was performed in a mercury free environment. All testing performed in accordance with
the latest edition of the applicable ASTM, or other Federal Test Method in effect at the time of test.
Page 1 of 3
Date: 6/8/2018
P.O. No.: 081812
W/O No.: EXO006-06-05-65019-2

***CORRECTED TEST CERTIFICATE EAR-CONTROLLED DATA 6/14/18***

Grain Size Determination


Requirement: Information Only
QTY Tested: 1
Etchant used: Kalling’s 2
Sectioning, mounting, and polishing were done in accordance with ASTM E3 Rev. 2011, and then etched in order to reveal the
grain structure.
The grain size rating was performed in accordance to ASTM E-112 Rev. 2013. Results are as follows:
Average ASTM grain size : ASTM #12.0

Sample 2 500X***

Intergranular Attack
Requirement: Information Only
Qty. Tested: 1
Etchant used: As-Polished & Kalling’s 2
Sectioning, mounting and polishing were performed in accordance with ASTM E3 Rev. 2011, and then etched in order to reveal the microstructure.
The microstructure was evaluated at 500X magnifications with the following results:
The specimen does not show evidence of intergranular attack/oxidation.

Respectfully submitted
15062 Bolsa Chica, Huntington Beach, CA 92649
(714) 892-1961 ph • (714) 892-8159 fax www.element.com

**Denotes non-conforming results. ***Denotes change made from original test certificate.
The information contained in this certification represents only the material submitted and is certified only for the quantities tested. Reproduction
except in full is reserved pending written approval. The recording of false, fictitious, or fraudulent statements or entries on the certificate may be
punishable as a felony under federal law. All testing was performed in a mercury free environment. All testing performed in accordance with
the latest edition of the applicable ASTM, or other Federal Test Method in effect at the time of test.
Page 2 of 3
Date: 6/8/2018
P.O. No.: 081812
W/O No.: EXO006-06-05-65019-2

***CORRECTED TEST CERTIFICATE EAR-CONTROLLED DATA 6/14/18***

Microhardness Evaluation
Requirement: FOR INFO. ONLY
Load in grams: 500g
Magnification: 400X
Hardness results are an average of at least three readings tested in accordance with ASTM E-384 (17).
Sample Vickers Rockwell HRC
TRAPINCHE 47 311 31
Approximate conversion per ASTM E-140 (12bE1)

Nadcap MTL Accredited by PRI, Certificate No. 3658172995, Expires 31 January 2019.
ISO 17025 Accredited by A2LA for Testing, Certificate Nos. 0093.01 & 0093.02, Expires 31 May 2018.

FOR INFORMATION ONLY


This document, which includes any attachments and exhibits hereto, was exported from the United States in accordance with the Export Administration
Regulations. Diversion contrary to U.S. law is prohibited.

This document contains technical data whose export and re-export/re-transfer is subject to control by the U.S. Department of Commerce under the Export
Administration Act and the Export Administration Regulations. The Department of Commerce’s prior written approval is required for the export or re-export/re-
transfer of such technical information to any foreign person, foreign entity or foreign organization whether in the United States or abroad. These commodities,
technology or software were exported from the United States in accordance with the Export Administration Regulations. Diversion contrary to U.S. law is
prohibited.

Respectfully submitted
15062 Bolsa Chica, Huntington Beach, CA 92649
(714) 892-1961 ph • (714) 892-8159 fax www.element.com

**Denotes non-conforming results. ***Denotes change made from original test certificate.
The information contained in this certification represents only the material submitted and is certified only for the quantities tested. Reproduction
except in full is reserved pending written approval. The recording of false, fictitious, or fraudulent statements or entries on the certificate may be
punishable as a felony under federal law. All testing was performed in a mercury free environment. All testing performed in accordance with
the latest edition of the applicable ASTM, or other Federal Test Method in effect at the time of test.
Page 3 of 3