1. Design Criteria
1.1 General 1
1.2 Codes & Standards 1
1.3 Material Strengths 1
1.4 Design Loads 2

2. Properties
2.1 Materials 3
2.2 Frame Sections 3
2.3 Shell Sections 3
3. Loads
3.1 Load Patterns 4
3.2 Auto Seismic Loading 4
3.3 Load Cases 5
3.4 Load Combinations 5

4. Model snap shots 7


5/26/2015

1 Design Criteria
1.1 GENERAL:

Purpose of this presentation is to outline methodology for Structural Design. The Structural System
shall be a “Moment Resisting Frame System” (as per UBC – 97). An essentially complete space frame
shall provide support for vertical loads and lateral loads. The space frame shall be detailed as an
Intermediate Moment Resisting Frame concrete structure with infill brick masonry walls in Zone 2B
(Building Code of Pakistan with Seismic Provision BCP-2007).

1.2 CODES & STANDARDS:

The American codes & standards have been used for the design of the structure.

 ACI 318–08 Building Code Requirements For Structural Concrete


 BCP-2007 Building code of Pakistan (Seismic Provisions – 2007)
 IBC 2009 International Building Code
 UBC 1997 Uniform Building Code
 ASTM American Standards for Testing of Materials
 ASCE 7-05 Minimum Design Loads for Buildings and other structures

1.3 MATERIAL STRENGTHS:

Concrete Cylinder Strengths at 28 days:

 Columns & Floor, Roof Beams 3000 psi ( 210 kg/m2 )


 RCC Slabs 3000 psi ( 210 kg/m2 )

Reinforcing Bars: Yield Strength:

 Reinforcing steel Grade- 40 (40,000 psi)

Page 1 of 10
5/26/2015

1.4 DESIGN LOADS:

Dead Loads (D)


Live Loads (L)
Superimposed Dead Loads
Earthquake Loads (E)

Dead Loads:

Following specific weights have been used for computing dead loads.

 Reinforced Concrete 150 lbs/ ft3 ( 23.46 KN/m3 )


 Plain Cement Concrete 144 lbs/ ft3 ( 22.46 KN/m3 )
 Brick Masonry 120 lbs/ ft3 (18.72 KN/m3 )
 Plaster 144 lbs/ ft3 ( 22.46 KN/m3 )

Live Loads:

The live loads imposed on the floors have been classified according to the use of the floors.
Live load on Offices = 50 psf
Live load on corridor = 80 psf
Live load on Roof = 30 psf

Superimposed Dead Loads:

 Floor finish 40 lbs/ft2


 9” & 4-1/2” Brick masonry walls Loads applied as per location and weights of the walls

Earthquake Loads (E):

Earthquake loading have been based upon UBC 1997 & followings.

 Seismic Zone 2B
 Soil Profile Type SD.
 Response Modification Factor 5.5

Page 2 of 10
5/26/2015

2 Properties

This chapter provides property information for materials, frame sections and shell sections.

2.1 Materials

Table 2.1 - Material Properties - Summary

Unit
E
Name Type ν Weight Design Strengths
lb/in²
lb/ft³
3000Psi Concrete 3122018.6 0.2 150 Fc=3000 lb/in²
Fy=40000 lb/in²,
A615Gr40 Rebar 29000000 0.3 490
Fu=60000 lb/in²

Table 2.2 - Material Properties - Concrete

Unit
E α G Unit Mass Fc
Name ν Weight
lb/in² 1/F lb/in² lb-s²/ft⁴ lb/in²
lb/ft³
3000Psi 3122018.6 0.2 5.5E-06 1300841.08 150 4.662 3000

Table 2.3 - Material Properties - Rebar

Unit
E α Unit Mass Fy Fu
Name Weight
lb/in² 1/F lb-s²/ft⁴ lb/in² lb/in²
lb/ft³
A615Gr40 29000000 6.5E-06 490 15.23 40000 60000

2.2 Frame Sections

Table 2.4 - Frame Sections - Summary

Name Material Shape


Concrete
BM12X15 3000Psi
Rectangular
Concrete
BM9X15 3000Psi
Rectangular
Concrete
COL12X15 3000Psi
Rectangular
Concrete
COL12X12 3000Psi
Rectangular
Concrete
COL9X15 3000Psi
Rectangular

2.3 Shell Sections

Table 2.5 - Shell Sections - Summary

Total
Design Element
Name Material Thickness
Type Type
in
SLAB6 Slab Shell-Thin 3000Psi 6

Page 3 of 10
5/26/2015

3 Loads
This chapter provides loading information as applied to the model.

3.1 Load Patterns

Table 3.1 - Load Patterns

Self
Name Type Weight Auto Load
Multiplier
Dead Dead 1
Live Live 0
Superimposed
SDL 0
Dead
EQX Seismic 0 UBC 97
EQY Seismic 0 UBC 97

3.2 Auto Seismic Loading

Table 3.2 - Auto Seismic - UBC 97 (Part 1 of 2)

Eccentri
Load Directio Period Ct Top Bottom Soil
Type city R Z Ca
Pattern n Method ft Story Story Type
%
Program
EQX Seismic X 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQX Seismic X + Ecc. Y 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQX Seismic X - Ecc. Y 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y + Ecc. X 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y - Ecc. X 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated

Table 3.2 - Auto Seismic - UBC 97 (Part 2 of 2)

Period Weight Base


Cv Na Nv I Used Used Shear
sec kip kip
0.4 1.5 2 1.25 0.336 1868.104 297.198
0.4 1.5 2 1.25 0.336 1868.104 297.198
0.4 1.5 2 1.25 0.336 1868.104 297.198
0.4 1.5 2 1.25 0.336 1868.104 297.198
0.4 1.5 2 1.25 0.336 1868.104 297.198
0.4 1.5 2 1.25 0.336 1868.104 297.198

Page 4 of 10
5/26/2015

3.3 Load Cases

Table 3.5 - Load Cases - Summary

Name Type
Dead Linear Static
Live Linear Static
SDL Linear Static
EQX Linear Static
EQY Linear Static

3.4 Load Combinations

Table 3.6 - Load Combinations

Load
Scale
Name Case/Comb Type
Factor
o
DCon0 Live 1 Linear Add
DCon0 Dead 1
DCon0 SDL 1
DCon1 Dead 1.4 Linear Add
DCon1 SDL 1.4
DCon2 Dead 1.2 Linear Add
DCon2 Live 1.6
DCon2 SDL 1.2
DCon3 Dead 1.3 Linear Add
DCon3 Live 1
DCon3 SDL 1.3
DCon3 EQX 1
DCon4 Dead 1.3 Linear Add
DCon4 Live 1
DCon4 SDL 1.3
DCon4 EQX -1
DCon5 Dead 1.3 Linear Add
DCon5 Live 1
DCon5 SDL 1.3
DCon5 EQY 1
DCon6 Dead 1.3 Linear Add
DCon6 Live 1
DCon6 SDL 1.3
DCon6 EQY -1
DCon7 Dead 1.3 Linear Add
DCon7 SDL 1.3
DCon7 EQX 1
DCon8 Dead 1.3 Linear Add
DCon8 SDL 1.3
DCon8 EQX -1
DCon9 Dead 1.3 Linear Add
DCon9 SDL 1.3
DCon9 EQY 1
DCon10 Dead 1.3 Linear Add
DCon10 SDL 1.3
DCon10 EQY -1
DCon11 Dead 0.8 Linear Add
DCon11 EQX 1

Page 5 of 10
5/26/2015

Load
Scale
Name Case/Comb Type
Factor
o
DCon12 Dead 0.8 Linear Add
DCon12 EQX -1
DCon13 Dead 0.8 Linear Add
DCon13 EQY 1
DCon14 Dead 0.8 Linear Add
DCon14 EQY -1

Page 6 of 10
5/26/2015

MODEL FRAME

WALL LOAD ASSIGNED in kip/ft

Page 7 of 10
5/26/2015

AREAS OF LONGITUDINAL REINFORCEMENTS in in2

SLAB DEFLECTION CONTOURS

Page 8 of 10