Professional Documents
Culture Documents
Category-D Hospital
Designed by: Engr. Junaid Shah
Table Of Content
1. Design Criteria
1.1 General 1
1.2 Codes & Standards 1
1.3 Material Strengths 1
1.4 Design Loads 2
2. Properties
2.1 Materials 3
2.2 Frame Sections 3
2.3 Shell Sections 3
3. Loads
3.1 Load Patterns 4
3.2 Auto Seismic Loading 4
3.3 Load Cases 5
3.4 Load Combinations 5
1 Design Criteria
1.1 GENERAL:
Purpose of this presentation is to outline methodology for Structural Design. The Structural System
shall be a “Moment Resisting Frame System” (as per UBC – 97). An essentially complete space frame
shall provide support for vertical loads and lateral loads. The space frame shall be detailed as an
Intermediate Moment Resisting Frame concrete structure with infill brick masonry walls in Zone 2B
(Building Code of Pakistan with Seismic Provision BCP-2007).
The American codes & standards have been used for the design of the structure.
Page 1 of 10
5/26/2015
Dead Loads:
Following specific weights have been used for computing dead loads.
Live Loads:
The live loads imposed on the floors have been classified according to the use of the floors.
Live load on Offices = 50 psf
Live load on corridor = 80 psf
Live load on Roof = 30 psf
Earthquake loading have been based upon UBC 1997 & followings.
Seismic Zone 2B
Soil Profile Type SD.
Response Modification Factor 5.5
Page 2 of 10
5/26/2015
2 Properties
This chapter provides property information for materials, frame sections and shell sections.
2.1 Materials
Unit
E
Name Type ν Weight Design Strengths
lb/in²
lb/ft³
3000Psi Concrete 3122018.6 0.2 150 Fc=3000 lb/in²
Fy=40000 lb/in²,
A615Gr40 Rebar 29000000 0.3 490
Fu=60000 lb/in²
Unit
E α G Unit Mass Fc
Name ν Weight
lb/in² 1/F lb/in² lb-s²/ft⁴ lb/in²
lb/ft³
3000Psi 3122018.6 0.2 5.5E-06 1300841.08 150 4.662 3000
Unit
E α Unit Mass Fy Fu
Name Weight
lb/in² 1/F lb-s²/ft⁴ lb/in² lb/in²
lb/ft³
A615Gr40 29000000 6.5E-06 490 15.23 40000 60000
Total
Design Element
Name Material Thickness
Type Type
in
SLAB6 Slab Shell-Thin 3000Psi 6
Page 3 of 10
5/26/2015
3 Loads
This chapter provides loading information as applied to the model.
Self
Name Type Weight Auto Load
Multiplier
Dead Dead 1
Live Live 0
Superimposed
SDL 0
Dead
EQX Seismic 0 UBC 97
EQY Seismic 0 UBC 97
Eccentri
Load Directio Period Ct Top Bottom Soil
Type city R Z Ca
Pattern n Method ft Story Story Type
%
Program
EQX Seismic X 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQX Seismic X + Ecc. Y 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQX Seismic X - Ecc. Y 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y + Ecc. X 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Program
EQY Seismic Y - Ecc. X 5 0.03 GF Base 5.5 SD 0.2 0.28
Calculated
Page 4 of 10
5/26/2015
Name Type
Dead Linear Static
Live Linear Static
SDL Linear Static
EQX Linear Static
EQY Linear Static
Load
Scale
Name Case/Comb Type
Factor
o
DCon0 Live 1 Linear Add
DCon0 Dead 1
DCon0 SDL 1
DCon1 Dead 1.4 Linear Add
DCon1 SDL 1.4
DCon2 Dead 1.2 Linear Add
DCon2 Live 1.6
DCon2 SDL 1.2
DCon3 Dead 1.3 Linear Add
DCon3 Live 1
DCon3 SDL 1.3
DCon3 EQX 1
DCon4 Dead 1.3 Linear Add
DCon4 Live 1
DCon4 SDL 1.3
DCon4 EQX -1
DCon5 Dead 1.3 Linear Add
DCon5 Live 1
DCon5 SDL 1.3
DCon5 EQY 1
DCon6 Dead 1.3 Linear Add
DCon6 Live 1
DCon6 SDL 1.3
DCon6 EQY -1
DCon7 Dead 1.3 Linear Add
DCon7 SDL 1.3
DCon7 EQX 1
DCon8 Dead 1.3 Linear Add
DCon8 SDL 1.3
DCon8 EQX -1
DCon9 Dead 1.3 Linear Add
DCon9 SDL 1.3
DCon9 EQY 1
DCon10 Dead 1.3 Linear Add
DCon10 SDL 1.3
DCon10 EQY -1
DCon11 Dead 0.8 Linear Add
DCon11 EQX 1
Page 5 of 10
5/26/2015
Load
Scale
Name Case/Comb Type
Factor
o
DCon12 Dead 0.8 Linear Add
DCon12 EQX -1
DCon13 Dead 0.8 Linear Add
DCon13 EQY 1
DCon14 Dead 0.8 Linear Add
DCon14 EQY -1
Page 6 of 10
5/26/2015
MODEL FRAME
Page 7 of 10
5/26/2015
Page 8 of 10