Professional Documents
Culture Documents
Abstract: To understand the basic characteristics of the human body vibration induced by low
frequency noise and to use it to evaluate the effects on health, we designed a measuring method with
a miniature accelerometer and carried out preliminary measurements. Vibration was measured on
the chest and abdomen of 6 male subjects who were exposed to pure tones in the frequency range of
20 to 50 Hz, where the method we designed was proved to be sensitive enough to detect vibration on
the body surface. The level and rate of increase with frequency of the vibration turned out to be
higher on the chest than on the abdomen. This difference was considered to be due to the mechanical
structure of the human body. It also turned out that the measured noise-induced vibration negatively
correlated with the subject's BMI (Body Mass Index), which suggested that the health effects of low
frequency noise depended not only on the mechanical structure but also on the physical constitution
of the human body.
Key words: Low frequency noise, Human body vibration, Body surface, Miniature accelerometer, Chest,
Abdomen, Body mass index (BMI)
on DAT (DigitalAudio Tape) with a data recorder (PC216Ax, beginning and end of each stimulus, only a 40-second length
Sony Precision Technology, Japan). of each set of data was analyzed by neglecting the head (10
Fifteen kinds of the low frequency noise stimuli (5 s) and tail (10 s) parts. In the case of a noise stimulus, a
frequencies x 3 sound pressure levels) were reproduced by spectral component (mY) at the frequency corresponding
12 loud speakers13)(TL-1801, Pioneer, Japan) installed in to the stimulus was converted to an acceleration (m/s2
the wall in front of the subject (Fig. 1). All of them were (r.m.s.)), being multiplied by a conversion coefficient
pure tones the frequencies of which were 20, 25, 3 40 obtained in the calibration measurement. In the case of no
and 50 Hz, and the sound pressure levels of which were noise stimulus, spectral components at five frequencies (20,
100,105 and 110 dB (SPL), respectively. The input to the 25, 3 40 and 50 Hz) were converted to accelerations.
loud speakers was adjusted so that the desired sound pressure This study was approved by the institutionalethical inquiry
level could be measured at the center of the test chamber, committee established in conformity to the Declaration of
100 cm high (corresponding to the chest of a subject sitting Helsinki16>,and informed consent of each subject was
on a chair), without a subject present. During the obtained before measurement.
measurement the sound pressure levels of the noise stimuli
were monitored by a low frequency sound level meter (NA- Evaluation of the Methods
17, Rion, Japan) in the test chamber (Fig. 1). The levels of
higher harmonics of the noise stimuli had been turned Figure 2 shows typical examples of the power spectra
sufficiently low when the stimuli were reproduced at the obtained on the left chest of a subject. Figure 2 (a)
levels of 110 dB or less13~ corresponds to the case of no exposure and Fig. 2 (b)
The subject who wore no clothes on the upper half of the corresponds to the case with exposure to 50 Hz, 100 dB
body to allow the accelerometers to be attached was exposed noise stimulus. Remarkable spectral components appearing
to the noise stimuli sitting on a chair at the center of the test around 10 Hz, which were found for all of the subjects
chamber (Fig. 1). He sat erect on the chair with his back independently of the noise stimuli, were considered to
more than 10 cm from its backrest. The temperature in the originate in the heart beat. Because these inherent spectral
chamber was initially set at 25°C at his position (not components were larger than the noise-induced ones, the
controlled to be uniform in the whole of the chamber) and, measuring method was proved not to be applicable to
if he complained, adjusted within the 23-27°C range to keep measurement in a frequency range lower than 20 Hz.
him comfortable and prevent him from sweating. The Inherent spectral components turned out to be very small
humidity in the chamber could not be controlled because of (Fig. 2 (a)) in the frequency range higher than 50 Hz for all
lack of the equipment to control it but we verified that it the subjects, whereas another difficulty was noticed in this
was stable within the 25-35% range. The illuminance in frequency range. The poor uniformity of the sound pressure
the chamber was about 90 lx at the center of it, 100 cm levels in the test chamber13~,which is one of its intrinsic
above the floor. properties, possibly made it difficult to condition the sound
The subject was instructed to be in the test chamber for pressure levels bordering on the subject's body surface to
10 min before the measurement in order to adjust to the be homogeneous. This was difficult to improve and resulted
temperature and atmosphere. After the adjusting period, in limiting the upper limit of the frequency range of the
the accelerometers were attached and the measurement noise stimuli to 50 Hz.
started. At first the inherent vibration with no noise stimulus In the frequency range from 20 to 50 Hz, the measuring
was recorded (1 min). And then a rest period with no noise method was proved to be sensitive enough for our purpose.
stimulus (1 min) and an exposure period with a noise stimulus As shown in Fig. 2 (b), an evident peak of the noise-induced
(1 min) when the vibration at each measuring position was vibration was found at the frequency corresponding to the
recorded were continued alternately. Fifteen kinds of noise noise stimulus (50 Hz, 100 dB). But, because the phase
stimuli were presented in random order for every subject. relationship between the noise-induced vibration and the
The data recorded on DAT were analyzed by means of an inherent one was unknown, the noise-induced spectral
FFT analyzer (HP3566A, Hewlett Packard, USA) and the component was simply converted to an acceleration without
power spectrum was obtained for every measuring position subtracting the amount of the inherent one in any of the
and every noise stimulus, including no exposure. For cases. Therefore, the measured accelerations were probably
eliminating the transient responses corresponding to the contributed by the inherent components and the contribution
Fig. 2. Typical examples of the power spectrum obtained on the left chest of a subject.
(a) with no exposure and (b) with exposure to 50 Hz, 100 dB noise stimulus. Inherent spectral components around 10 Hz
were considered to originate in the heart beat. An evident peak corresponding to the noise stimulus was found at 50 Hz
in (b).
was supposed to be larger at lower frequencies (20 and 25 Tables 1 and 2 show the results of the statistical analysis
Hz). For verifying the significance of the measured mentioned previously. For 110 dB, all the accelerations
accelerations (means ± SD), statistical analysis (ANOVA measured with the noise exposure were significantly (p<0.01,
followed by multiple comparison) with SPSS software was two-sided) larger than the inherent ones with no exposure.
performed on the difference between the measured At higher frequencies (31.5, 40 and 50 Hz), almost all of
accelerations and the inherent one for every measuring the accelerations measured on the chest with the noise
position. The results of the statistical analysis are discussed exposure, except in the case of 40 Hz, 100 dB stimulus,
below. were significantly (p<0.05, two-sided) greater than the
inherent ones (Table 1). On the abdomen (Table 2), similar
Results results were obtained at still higher frequencies (40 and 50
Hz). These results showed clearly that the unusual vibrations
Here only the results obtained on the left half of the body were induced on the human body by low frequency noise,
(on the left chest and on the left abdomen) are shown because but distinguishing them from the inherent ones was difficult
no difference was found between the results obtained on in lower frequencies and at lower sound pressure levels.
the right half of the body and those on the left. The noise- In Figs. 3 and 4, the measured accelerations (means ± SD)
induced vibrations corresponding to higher harmonics of are presented in terms of an acceleration level defined as
the noise stimuli could not be detected in the frequency range
Acceleration level = 201og10 (a/aa)
up to 100 Hz in any of the cases.
32 Y TAKAHASHI et al.
Table 1. Statistical significance of the difference between the noise-induced accelerations (means ± SD) measured
on the left chest and the inherent ones with no exposure
Table 2. Statistical significance of the difference between the noise-induced accelerations (means ± SD) measured on
the left abdomen and the inherent ones with no exposure
Fig. 4. The measured acceleration levels plotted as a function of the subject's BMI.
(a) on the left chest, for 110 dB noise stimulus, (b) on the left chest, for 100 dB, (c) on the left abdomen, for 110 dB and (d) on the left abdomen, for
100 dB. On the chest, the acceleration levels negatively correlated with BMI at higher frequencies (40 and 50 Hz), whereas no apparent tendency
was found at lower frequencies (20, 25 and 31.5 Hz). On the abdomen, a negative correlation with BMI was found at all frequencies.
(20 and 25 Hz) the difference between them was not clear on the chest negatively correlated with BMI at higher
because of large inherent vibrations. frequencies (40 and 50 Hz) but no apparent correlation was
Since the noise-inducedvibration is a mechanical response found at lower frequencies (20, 25 and 31.5 Hz). On the
to the noise, its characteristics are supposed to depend on abdomen (Figs. 4 (c) and (d)), on the other hand, a negative
the mechanical characteristics of the human body. To verify correlation with BMI was found at all frequencies. The
this, the acceleration levels measured with the noise stimuli patterns of correlation were found to be unchanged with
at the levels of 100 and 110 dB are plotted as a function of the sound pressure level of the noise stimulus both on the
the subject's BMI in Fig. 4. The BMI (Body Mass Index), chest and on the abdomen.
which is defined as
Discussion
BMI = W/H2
where W is the weight (kg) and H is the height (m), is a The maximum measured accelerations were 0.17 m/s2
quantity in close correlation with the amount of fat in the (r.m.s.) on the chest and 0.062 m/s2(r.m.s.) on the abdomen,
body and prevalently utilized as an index of obesity. The respectively, both of which were measured with 50 Hz, 110
fat is considered to contribute to the mechanical dB noise stimulus (Tables 1 and 2). By multiplying them
characteristics, such as stiffness, of the human body. As by the weighting factor, equal to 0.0388 at 50 Hz, for the
shown in Figs. 4 (a) and (b), the acceleration level measured whole-body horizontal vibration standardized as ISO 2631-
34 Y TAKAHASHI et al.
117),they are converted to the weighted r.m.s. accelerations, found for the human uterus2S~. Apart from the gender
0.0066 m/s2 (r.m.s.) and 0.0024 m/s2 (r.m.s.), respectively. difference, their results imply that the abdominal noise-
These levels are lower than the level of vibration at which induced vibration in our measurement is promoted in
the health effects are expected17~.Nevertheless, the noise- frequency ranges below 100 Hz.
induced vibration is deduced to be an isotropic one because In discussing noise-induced vibration, it is important to
the wavelength of low frequency noise (6.8 m for 50 Hz consider its generating and propagating mechanism in the
pure tone, supposing the sound velocity to be 340 m/s) is human body. The mechanism was not clarified by our results,
larger than the size of a man, whereas the standard treated but Fig. 4 implies that the fat in the body damps the vibration
the vibration induced in one direction. Because of this or obstructs its propagation through the body. Figure 4 also
difference, the validity of applying the standard in the case suggests that these damping characteristics are position-
of noise-induced vibration is uncertain, and it should not be dependent and frequency-dependent. Although we cannot
concluded that the low-level noise-induced vibration causes affirm that BMI is the most appropriate index of the
no health effect. relationshipbetween noise-inducedvibration and the physical
Yamada et al. 18)reported that a deaf person perceived low constitution of the human body, these results suggest that
frequency noise through a vibratory sensation on the chest. the characteristics of noise-induced vibration depend not
Our results shown in Fig. 3 are not in conflict with their only on the mechanical structure but also on the physical
work, but rather confirm it quantitatively, though evident constitution of the human body.
consistency is not proved because of the small number of In this study we measured noise-induced vibration on the
measuring positions in our study. Higher acceleration levels chest and the abdomen with a measuring method we designed.
and steeper rates of increase with frequency measured on The result suggested that its basic characteristics depended
the chest are presumed to result from easier induction of a on the mechanical structure and physical constitution of the
vibration on the lung which is organized like a balloon and human body. In other words, it appeared that the mechanical
linked to the atmosphere through the airway. Figure 3 (a) characteristics of the human body were important factors
implies that the acceleration levels measured on the chest in evaluating low frequency noise from the standpoint of
still increase in frequency ranges higher than 50 Hz. Wodicka its health effects. Nevertheless, it remains unknown how
et al. showed experimentally19~and theoretically20>that the vibrations measured on the body surface are related to
acceleration measured on the posterior chest wall peaked vibrations in the body such as the internal organs, for which
in the frequency range between 100 and 200 Hz when a it cannot be concluded what chronic health effects are caused
noise stimulus with a frequency range above 100 Hz was by long term exposure to low frequency noise. In addition,
injected directly into the subject's mouth. Apart from different the characteristics of noise-induced vibration are supposed
experimental conditions, their results suggest that the noise- to depend on other factors such as the subject's posture,
induced vibration on the chest increases further, up to gender difference, temperature, humidity and so on. Further
frequencies around 150 or 200 Hz. detail investigations are desired in order to understand all
On the abdomen, on the other hand, the noise-induced of the characteristics of noise-induced vibration and to relate
acceleration levels were lower (by about 10 dB) than those them to vibration in the inner body and the health effects on
on the chest at frequencies above 31.5 Hz (Fig. 3) and their man.
rates of increase with frequency were gentler. It is deduced
that crowdingof the internal organs and tissue in the abdomen Acknowledgments
hinders induction of a vibration. In connection with
abdominal vibration, Abrams et al. carried out a series of This study was supported in part by a fund from the
interesting experiments from a viewpoint concerned about Environmental Agency of Japan.
the effect on a fetus. They applied the vibration stimulus21-23)
and the noise stimulus24)to the abdomen of a ewe, as a model References
for a woman, and measured the vibration (sound pressure)
within the abdomen. As a result, they proved that the vibration 1) International Organization for Standardization (1990)
(sound pressure) with a frequency range below 100Hz hardly Acoustics-Determination of occupational noise
attenuated and penetrated into the deeper regions of the exposure and estimation of noise-induced hearing
abdomen. Similar less attenuation of vibration was also impairment. ISO 1999.
2) International Organization for Standardization (1997) 15) VermarienH, van VollenhovenE (1984) The recording
Acoustics-Guidelines for the measurement and of heart vibrations:A problem of vibration measurement
assessment of exposure to noise in a working on soft tissue. Med Biol Eng Comput 22,168-78.
environment. ISO 9612. 16) Anonymous (1997) World Medical Association,
3) International Organization for Standardization (1987) Declaration of Helsinki, recommendations guiding
Acoustics-Normal equal-loudness level contours. ISO physicians in biomedical research involving human
226. subjects. J Am Med Assoc 277, 925-6.
4) Berglund B, Hassmen P, Job RFS (1996) Sources and 17) International Organization for Standardization (1997)
effects of low-frequency noise. J Acoust Soc Am 99, Mechanical vibration and shock-Evaluation of human
2985-3002. exposure to whole-body vibration-Part l: General
5) Backteman 0, Kohler J, Sjoberg L (1983) Infrasound- requirements. ISO 2631-1.
Tutorial and review: Part 1. J Low Freq Noise Vib 2, 18) Yamada S, Watanabe T, Kosaka T (1983) Sensory
1-31. organs of low frequency noise. J INCE Jpn 7, 282-4
6) Backteman 0, Kohler J, Sjoberg L(1983) Infrasound- (in Japanese).
Tutorial and review: Part 2. J Low Freq Noise Vib 2, 19) Wodicka GR, Shannon DC (1990) Transfer function
176-210. of sound transmission in subglottal human respiratory
7) Backteman 0, Kohler J, Sjoberg L(1984) Infrasound- system at low frequencies. J Appl Physiol 69, 2126-
Tutorial and review: Part 3. J Low Freq Noise Vib 3, 30.
28-67. 20) Wodicka GR, Stevens KN, Golub HL, Cravalho EG,
8) Backteman 0, Kohler J, Sjoberg L(1984) Infrasound- Shannon DC (1989) A model of acoustic transmission
Tutorial and review: Part 4. J Low Freq Noise Vib 3, in the respiratory system. IEEE Trans Biomed Eng 36,
96-113. 925-34.
9) Broner N, Leventhall HG (1983) Low frequency noise 21) Abrams RM, Gerhardt KJ, Kelly-Jones A, Huang X,
annoyance assessment by low frequency noise rating Peters AJM (1997) Accelerationof the fetal head: Effect
(LFNR) curves. J Low Freq Noise Vib 2, 20-8. of distance from vibration source. J Sound Vib 206,
10) Inukai Y, Taya H, Nagamura N, Kuriyama H (1987) 442-7.
An evaluation method of combined effects of infrasound 22) Peters AJM, Abrams RM, Gerhardt KJ, Burchfield DJ,
and audible noise. J Low Freq Noise Vib 6,119-25. WassermanDE (1992) Resonance of the pregnant sheep
11) International Organization for Standardization (1995) uterus. J Low Freq Noise Vib 11,1-6.
Acoustics-Frequency-weighting characteristic for 23) Peters AJM, Abrams RM, Gerhardt KJ, Longmate JA
infrasound measurements. ISO 7196. (1991) Three dimensional sound and vibration
12) Inukai Y, Taya H, Miyano H, Kuriyama H (1986) A frequency responses of the sheep abdomen. J Low Freq
multidimensional evaluation method for the Noise Vib 10,100-11.
psychological effects of pure tones at low and infrasonic 24) Peters AJM, Gerhardt KJ, Abrams RM, Longmate JA
frequencies. J Low Freq Noise Vib 5,104-12. (1993) Three-dimensional intraabdominal sound
13) Takahashi Y, YonekawaY, Kanada K, Maeda S (1997) pressures in sheep produced by airborne stimuli. Am J
An infrasound experiment system for industrialhygiene. Obstet Gynecol 169,1304-15.
Ind Health 35, 480-8. 25) Richards DS, Frentzen B, Gerhardt KJ, McCann ME,
14) Kitazaki S, Griffin MJ (1995) A data correction method Abrams RM (1992) Sound levels in the human uterus.
for surface measurement of vibration on the human Obstet Gynecol 80,186-90.
body. J Biomech 28, 885-90.