You are on page 1of 76

Pump Product Catalog

Experience In Motion
Pump Supplier to the World
Flowserve is the driving force in the global Product Brands of Distinction
industrial pump marketplace. No other pump
ACEC™ Centrifugal Pumps
company in the world has the depth or breadth
of expertise in the successful application of Aldrich ® Pumps
pre-engineered, engineered and special purpose
Byron Jackson ® Pumps
pumps and systems.
Calder™ Energy Recovery Devices

Cameron ® Pumps

Durco ® Pumps

Flowserve ® Pumps

IDP ® Pumps

Jeumont-Schneider™ Pumps

Niigata Worthington™ Pumps

Pacific ® Pumps

Pleuger ® Pumps

Scienco ® Pumps

Sier-Bath ® Rotary Pumps

TKL™ Pumps

United ® Centrifugal Pumps

Western Land Roller ® Irrigation Pumps

Wilson-Snyder ® Pumps

Worthington ® Pumps

Worthington Simpson ® Pumps

2
flowserve.com

Pump Designs
Flowserve offers a wide range of complementary
pump types, built to recognized global standards Committed to the Complete Pump
and customer specification. These include: System Life Cycle
• Single stage process
• Between bearings single stage For more than two centuries, Flowserve has
• Between bearings multistage served industries requiring solutions that add
value and reduce costs throughout the life
• Vertical
cycle of a pumping system.
• Submersible motor
• Oil and gas
• Positive displacement
• Chemical
• Nuclear
• Power generation
• Specialty
• Water
• General industry
Available Configurations
Flowserve partners
• Sealed and sealless
with customers to
• Axially and radially split respond to the
• Volute and diffuser dynamic business
• Close coupled and spacer coupled conditions that
• Single and double case affect them and to
improve efficiency, maximize throughput and
control process quality. Whether customer needs
involve on-site technical assistance, equipment
upgrades or broader project planning with full
turnkey responsibility, Flowserve delivers
professional, reliable results.

3
A Guide to Flowserve Pumps
The purpose of this publication is to provide a
brief summary of the hundreds of pumps which Oil and Gas
comprise the Flowserve product line. Pump
models are divided into five sections, beginning
with overhung pumps and continuing through Chemical
specialty designs. Each pump is identified by its
formal designation and accompanied by a full-
color cutaway illustration. Applicable engineering Power
standards are listed along with performance
characteristics and key features. The symbols
shown at right are used to identify each pump’s Water Resources
primary market applications.

For more information about Flowserve pumps, visit:


Mining
www.flowserve.com

Pulp and Paper

Primary Metals

General Industry

4
flowserve.com

Table of Contents
Pump Selection Guide............................................6-7 Positive Displacement
Product List.............................................................51
Overhung Pumps Gear.........................................................................52
Product List............................................................9 Screw.......................................................................53
Chemical Process........................................... 10-15 Reciprocating...........................................................54
API Process.................................................... 16-18
Slurry and Solids Handling............................. 19-22 Specialty Products
Industrial Process........................................... 23-25 Product List.............................................................57
Nuclear Pumps and Seals...................................58-61
Between Bearings Pumps Extreme Temperature Pumps...................................62
Product List..........................................................27 Others.................................................................63-65
Single Case - Axially Split - Single Stage........ 28-29
Single Case - Axially Split - Multistage.................30 Additional Information
Single Case - Radially Split - Single Stage............31 Introduction.............................................................67
Single Case - Radially Split - Multistage......... 32-34 Integrated Solutions Group.................................68-69
Double Case.................................................... 35-37 Other Flowserve Products........................................70
Reference Sources...................................................71
Vertical Pumps
Product List.............................................................39 Index
Wet Pit................................................................40-41 Product List........................................................72-73
Double Case........................................................42-43
Submersible.............................................................44
Slurry and Solids Handling.................................45-47
Sump..................................................................48-49 5
Pump Selection Oil and Gas Power Generation
Chemical Processing (Fossil, Renewables,
Guide Downstream Upstream & Pipeline Nuclear)

Residuum and Heavy Oil Upgrading


Gas Treating and Sulfur Recovery

Crude, Product and CO2 Pipeline


Heavy Oil, Oil Sands and Shale
Offsites and Waste Treatment

Volatile Organic Compounds


Water Supply and Treatment

Renewable Fuel Production

Flue Gas Desulfurization


Water and CO2 Injection

Caustic and Chlor-Alkali


Drilling and Production

Condensate Extraction
Boiler Feed Booster
Waste Processing
Slurry Processing
Catalytic Cracking

Pharmaceuticals
Hydrocracking

Gas to Liquids

Cooling Water
Hydrotreating

NGL and LPG

Acid Transfer

Boiler Feed
Distillation

Polymers

Auxiliary
Solvents
FPSO
Pump

LNG
Category Sub-Category
Overhung Chemical Process - X X X X X X X X X X X X X X X X X X
ANSI, ISO
API Process X X X X X X X X X X X X X X X X X X X X X X X X

Industrial Process X X X X X X X X X X X X
Slurry and Solids X X X X X X X X X X X X
Handling
Between Single Case - X X X X X X X X X X X X X X X X X X X X
Bearings Axially Split
Single Case - X X X X X X X X X X X X X X X X X X
Radially Split
Double Case X X X X X X X X X X X X
Vertical Wet Pit X X X X X X X X X

Double Case X X X X X X X X X X
Deep Well
X X X X X X
Submersible Motor
Slurry and X X X X X X X X X
Solids Handling
Sump X X X X X X X X X
Positive Gear X X X X X X X X
Displace-
ment Screw X X X X X X X X X X X X X

Multiphase X X

Reciprocating X X X X X X
Specialty Nuclear Pumps
Products
Nuclear Seals

Cryogenic Pumps X X
Cryogenic Liquid X
Expander
Geothermal
Deepwell
Submersible Pump
Hydraulic Decoking X
Systems
Power Recovery - X X X
Hydroturbine
Power Recovery -
DWEER
Thruster X X
CVP Concrete X
Volute Pumps
Barge Pump
Molten Salt
VTP Pump
X

X
X
Geothermal Well Services

X
X
Heat Transfer Fluids

X
X
X
Molten Salt Transfer

X
Transformer Cooling

X
X
X
X
X

X
X
X

X
X

X
X
X

X
Auxiliary Services

X
X
X
X
X

X
X
X
X
X
X

X
X
Nuclear)
(Fossil, Renewables,
Power Generation

Nuclear Service

X
X
X
X

X
X
X
X
X

X
X

X
Desalination

X
X
X

X
X
X
Flood Control

X
X
X
X

X
X

X
X
Ground Water Development and Irrigation

X
X
X
Sewage Collection and Treatment

X
X
X
X

X
X
X

X
Water Supply and Distribution
Water Resources

X
X
X
X
X

X
X

X
X
Water Treatment

X
X

X
X
X
Cooling Water

X
X
X

X
X
Descaling

X
X
X

X
X

Hydraulic Press

X
X
X

X
X

Plating, Galvanizing and Other Coatings


Primary Metals

X
X
X

X
X
Scale Recycle

X
X
X
X

X
X
X
X

X
Dewatering and Water Supply

X
X
X

X
X
X

Leaching Acid

X
X
X

X
X
Mining

Primary Processing
X

X
X
X
Slurry Transfer
X

X
X
X

X Bleach Chemical
X
X
X

X
X
X
X

Boiler Feed
X

X
X

X
X
X

Chemical and Liquor


X

X
X
X
X

Coatings
X
X

X
Digester
Pulp and Paper

X
X
X
Paper Stock
X
X

Shower Pumps
X
X
X
X

X
X
X

X
X
X
X

X
X

Automotive
X
X
X
X
X

X
X

X
X
X

X
X

Agriculture
X
X
X
X

X
X

X
X
X
X

X
X

Construction

X
X

Industrial Gases
X
X
X
X

X
X

X
X

X
X
X

X
X

Electronics
X
X
X
X

X
X

Fire Protection
X
X
X
X

X
X

X
X
X
X

X
X

Food Processing
General Industry

X
X
X
X

X
X

HVAC
X
X
X
X

X
X

X
X
X
X

OEM

X
X
X

Shipping
flowserve.com

X
X
X
X

X
X
X

Snowmaking
Overhung Pumps flowserve.com
Chemical Process
Mark 3 ASME Standard 10
Mark 3 Lo-Flo 10
Mark 3 Unitized Self-Primer 10
Mark 3 Recessed Impeller 11

Overhung Pumps
Mark 3 In-Line 11
Guardian Magnetic Drive 11
CPX3 ISO Standard 12
CPX3 Self-Priming 12
CPX3 Recessed Impeller 12
CPX3 Close Coupled 13
CPXV Chemical Sump 13
CPXS Magnetic Drive 13
PolyChem GRP 14
PolyChem VGRP 14
PolyChem S-Series 14
PolyChem M-Series 15
Polyshield 15
Polybase 15
API Process
HPX 16
HPXM 16
PHL 16
ERPN 17
PVXM 17
HWMA 17
PVML 18
MSP 18
DSVP 18
Slurry and Solids Handling
M 19
R 19
Titan Slurry 19
LC 20
MND 20
MNR 20
FRBH 21
FRBHJC 21
MPT 21
MF 22
MN 22
MSX 22
Industrial Process
D800 23
MEN 23
MENBLOC 23
ME 24
DS 24
SMP 24
SMX 25
F-Line 25
MVE 25

9
Mark 3 ASME Standard Mark 3 Lo-Flo Mark 3 Unitized
Self-Primer
Overhung – Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.1 • ASME (ANSI) B73.1 • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1680 m3/h (7400 gpm) • Flows to 50 m3/h (220 gpm) • Flows to 320 m3/h (1400 gpm)
• Heads to 215 m (700 ft) • Heads to 300 m (1000 ft) • Heads to 120 m (400 ft)
• Pressures to 27 bar (400 psi) • Pressures to 30 bar (450 psi) • Pressures to 20 bar (285 psi)
• Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F) • Temperatures to 370°C (700°F)
to 370°C (700°F) to 370°C (700°F) • Static suction lift to 6 m (20 ft)

Features Features Features


• Exclusive reverse vane impeller • Circular, concentric casing • Unitized casing with large priming
• Standard Mark 3A power end • Radial vane impeller chamber, air separator and volute
– External micrometer impeller • Standard Mark 3A power end • Exclusive reverse vane impeller
adjustment – External micrometer impeller standard; open impeller optional
­­­– Double row angular contact out- adjustment • Standard Mark 3A power end
board bearings and single row, ­­­– Double row angular contact out- – External micrometer impeller
deep groove inboard bearings board bearings and single row, adjustment
– Double lip oil seals deep groove inboard bearings ­­­– Double row angular contact out-
– Constant level oiler – Double lip oil seals board bearings and single row,
­– Large, reflective sight glass – Constant level oiler deep groove inboard bearings
• Choice of lubrication systems ­– Large, reflective sight glass – Double lip oil seals
• Optional ANSI 3A power end with • Choice of lubrication systems – Constant level oiler
lifetime warranty • Optional ANSI 3A power end with ­– Large, reflective sight glass
– Certified clean room assembly lifetime warranty • Choice of lubrication systems
– Inpro/Seal® VBXX isolators – Certified clean room assembly • Optional ANSI 3A power end with
– Magnetic drain plug – Inpro/Seal VBXX isolators lifetime warranty
• SealSentry™ seal chambers – Magnetic drain plug – Certified clean room assembly
• Largest shaft and bearing components • SealSentry seal chambers – Inpro/Seal VBXX isolators
in ANSI standard pumps • Oversized shaft and bearing – Magnetic drain plug
• Optional inducer components • SealSentry seal chambers
• Oversized shaft and bearing
Related Configurations See Bulletin PS-10-13 components
• Mark 3 Lo-Flo
® Inpro/Seal is a registered trademark of Inpro/Seal Company.
• Mark 3 Unitized Self-Primer See Bulletin PS-10-13
• Mark 3 Recessed Impeller
• Mark 3 Sealmatic dynamically sealed
10 See Bulletin PS-10-13
Mark 3 Recessed Mark 3 In-Line Guardian
Impeller Magnetic Drive

Overhung – Chemical Process


Standards Standards Standards
• Flowserve • ASME (ANSI) B73.2 • ASME (ANSI) B73.1 dimensions

Operating Parameters Operating Parameters Operating Parameters


• Flows to 455 m3/h (2000 gpm) • Flows to 370 m3/h (1630 gpm) • Flows to 375 m3/h (1650 gpm)
• Heads to 120 m (400 ft) • Heads to 230 m (760 ft) • Heads to 215 m (700 ft)
• Pressures to 20 bar (285 psi) • Pressures to 24 bar (350 psi) • Pressures to 24 bar (350 psi)
• Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F) • Temperatures from -75°C (-100°F)
to 370°C (700°F) to 370°C (700°F) to 290°C (550°F)

Features Features Features


• Low shear vortex pumping action • Exclusive reverse vane impeller • Magnetic drive design
• Fractional media contact with • Standard Mark 3A power end • Alloy C-276 containment shell
the impeller – External micrometer impeller • Rare earth magnets
• Standard CD4MCuN impeller adjustment • Low NPSHR, reverse vane impeller
• Thick-wall wet end components ­­­– Double row angular contact out- • Casings and impellers interchangeable
suitable for light slurries board bearings and single row, with sealed configuration
• Standard Mark 3A power end deep groove inboard bearings • Optimized internal lubrication path
– External micrometer impeller – Double lip oil seals • Silicon carbide bushings and journals
adjustment • Optional ANSI 3A power end with with double spiral grooves
­­­– Double row angular contact out- lifetime warranty • Standard and contained back pullout
board bearings and single row, – Certified clean room assembly • Options
deep groove inboard bearings – Inpro/Seal VBXX isolators – Fiber-optic leak detection
– Double lip oil seals • SealSentry seal chambers – Containment shell temperature
– Constant level oiler • Unique C-plus motor and pump shaft probes
­– Large, reflective sight glass alignment system – Process temperature probes
• Optional ANSI 3A power end with • Choice of bearing lubrication – External flush plans
lifetime warranty – Regreasable bearings
– Certified clean room assembly – Oil mist Available Configurations
– Inpro/Seal VBXX isolators – Permanently lubricated bearings • G-Series: -75°C (-100°F) to
– Magnetic drain plug 120°C (250°F)
• SealSentry seal chambers Related Configurations • H-Series: -120°C (-250°F) to
• Oversized shaft and bearing • Mark 3 in-line, recessed impeller 290°C (550°F)

Related Configurations See Bulletin PS-10-15 See Bulletin P-10-14


• Mark 3 ASME standard
• Mark 3 Sealmatic, recessed impeller

See Bulletin PS-10-13 11


Overhung – Chemical Process CPX3 ISO Standard CPX3 Self-Priming CPX3 Recessed Impeller

Standards Standards Standards


• ISO 2858 • ISO 2858 • ISO 2858
• ISO 5199 • ISO 5199 • ISO 5199

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1400 m3/h (6160 gpm) • Flows to 100 m3/h (440 gpm) • Flows to 750 m3/h (3300 gpm)
• Heads to 220 m (720 ft) • Heads to 100 m (330 ft) • Heads to 100 m (330 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F) • Temperatures from -80°C (-110°F)
to 350°C (660°F) to 350°C (660°F) to 350°C (660°F)
• 40 sizes with discharges from 20 mm
(0.75 in) to 200 mm (8 in) Features Features
• One-piece casing with integral priming • Heavy-duty casing with integral foot
Features chamber, air separator and volute and multi-ribbed discharge flange
• Heavy-duty casing with integral foot • Reflux priming principle eliminates • Vortex action minimizes abrasive
and multi-ribbed discharge flange need for internal valves and external wear and maintains solids integrity
• Reverse vane impeller standard; priming devices • Standard high-efficiency, semi-open
open impeller available • High-efficiency, low NPHSr, precision impeller precision cast in CD4MCuN
• SealSentry seal chambers cast, semi-open impeller duplex stainless steel
• Accepts multiple seal arrangements • Run dry capability • SealSentry seal chambers
• External micrometer impeller • SealSentry seal chambers • Accepts multiple seal arrangements
adjustment mechanism • Accepts multiple seal arrangements • External micrometer impeller
• Standard non-contacting labyrinth seal • External micrometer impeller adjustment mechanism
• Heavy-duty radial and thrust bearings adjustment mechanism • Standard non-contacting labyrinth seal
• One-piece, ductile iron bearing • Standard non-contacting labyrinth seal • Heavy-duty radial and thrust bearings
housing • Heavy-duty radial and thrust bearings • One-piece, ductile iron bearing
• Back pullout design • Back pullout design housing
• CE marked and compliant with • CE marked and compliant with • Back pullout design
applicable European directives such applicable European directives such • CE marked and compliant with
as ATEX; available with GOST cert. as ATEX; available with GOST cert. applicable European directives such
as ATEX; available with GOST cert.
Related Configurations Other Configurations
• CPX3 Self-Priming • CPX3 close coupled, self-priming Other Configurations
• Cpx3 Recessed Impeller • CPX3 magnetically driven, • CPX3 recessed impeller, vertical sump
• Cpx3 Close Coupled self-priming • CPX3 close coupled, recessed impeller
• CPXV Chemical Sump • CPX3 close coupled, magnetically
• CPX3 centerline mounted driven, self-priming See Bulletin PS-10-30
12 See Bulletin PS-10-30 See Bulletin PS-10-30
CPX3 Close Coupled CPXV Chemical Sump CPXS Magnetic Drive

Overhung – Chemical Process


Standards Standards Standards
• ISO 2858 • ISO 13709/API 610, 8th & 10th ed. • ISO 2858
• ISO 5199 • ISO 5199 • ISO 15783

Operating Parameters Operating Parameters Operating Parameters


• Flows to 750 m3/h (3300 gpm) • Flows to 1400 m3/h (6160 gpm) • Flows to 420 m3/h (1850 gpm)
• Heads to 100 m (330 ft) • Heads to 250 m (820 ft) • Heads to 160 m (525 ft)
• Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi) • Pressures to 25 bar (365 psi)
• Temperatures from -80°C (-110°F) • Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 350°C (660°F) to 350°C (660°F) to 250°C (480°F)

Features Features Features


• Compact, space-saving configuration • Heavy-duty casing with multi-ribbed • Reinforced PEEK® or Alloy C-276
• Investment cast muff coupling discharge flange primary containment shell
• Heavy-duty casing with integral foot • High-efficiency, semi-open impeller • Optional Alloy C-276 secondary
and multi-ribbed discharge flange • Column lengths to 10 m (32 ft) containment shell
• Radiating surfaces • Heavy-duty thrust bearings with axial • High-performance rare earth magnets
• Reverse vane impeller standard; adjustment above soleplate level • Large inner magnet clearances
open impeller available • Accepts multiple seal arrangements • Optimized internal flow circulation path
• SealSentry seal chambers • Elastomeric split element coupling • Heavy-duty casing with integral foot
• Accepts multiple seal arrangements • Options and multi-ribbed discharge flange
• External micrometer impeller −−Recessed impeller • High-efficiency, low NPHSr, precision
adjustment mechanism −−Suction strainer cast, semi-open impeller
• Accepts standard electric motors −−Spacer coupling • Advanced sintered silicon carbide
• Standard non-contacting −−Rectangular or circular soleplate bushings and journal bearings
labyrinth seal −−Oil lubrication to thrust bearing • Standard and contained back
• Back pullout design −−Zone Ø hazardous area beneath pullout design
• CE marked and compliant with soleplate configuration • CE marked and compliant with
applicable European directives such • CE marked and compliant with applicable European directives such
as ATEX; available with GOST cert. applicable European directives such as ATEX; available with GOST cert.
as ATEX; available with GOST cert.
Other Configurations Other Configurations
• CPX3 close coupled, recessed impeller Other Configurations • CPX3 close coupled, magnetic drive
• CPX3 close coupled, self-priming • CPX3 recessed impeller, • CPX3 magnetically driven,
• CPX3 close coupled, magnetic drive chemical sump self-priming
• Fully jacketed, molten salt design
See Bulletin PS-10-30 See Bulletin PS-10-30
See Bulletin PS-10-30
® Peek is a registered trademark of Victrex plc Corp. 13
PolyChem GRP PolyChem VGRP PolyChem S-Series
Engineered Polymer Engineered Polymer Fluoropolymer Lined
Composite Composite Sump
Overhung – Chemical Process

Standards Standards Standards


• ASME (ANSI) B73.5 • Flowserve • ASME (ANSI) B73.1
• ISO 2858
Operating Parameters Operating Parameters • JIS drilling
• Flows to 2050 m3/h (9000 gpm) • Flows to 565 m3/h (2500 gpm)
• Heads to 150 m (500 ft) • Heads to 110 m (350 ft) Operating Parameters
• Pressures to 17 bar (250 psi) • Pressures to 17 bar (250 psi) • Flows to 420 m3/h (1850 gpm)
• Temperatures from -45°C (-50°F) • Temperatures from -30°C (-20°F) • Heads to 145 m (480 ft)
to 120°C (250°F) to 90°C (200°F) • Pressures to 17 bar (250 psi)
• Temperatures from -30°C (-20°F)
Features Features to 150°C (300°F)
• Glass reinforced vinyl ester • Glass reinforced vinyl ester
• Unitized casing with integrally • Unitized casing with integrally Features
molded, fully gusseted suction and molded, fully gusseted suction and • PFA lined wet end
discharge flanges discharge flanges • Metal armor meets material
• Tapered polygon impeller drive • Externally adjustable, semi-open specifications of ASTM A395
• Seal chamber accommodates multiple impeller and GGG 40.3
seals, glands and flush arrangements • Shaft and bearing system operates • Enclosed impeller standard; open
• Standard Mark 3A power end well below the first critical speed impeller optional
– External micrometer impeller • Self-lubricated or external flush • Standard Mark 3A power end
adjustment mechanism bearings • SealSentry seal chamber
­­­– Double row angular contact out- • Single-piece, lightweight, filament- accommodates multiple seal types
board bearings and single row, wound, reinforced fiberglass • Shaft options
deep groove inboard bearings composite column – Standard silicon carbide shaft sleeve
– Double lip oil seals • Single and duplex configurations – Alloy shaft sleeves
– Constant level oiler • Full basket strainer – Solid shafts
• Optional ANSI 3A power end with • NEMA in-line motor • Bearing housing options
lifetime warranty • Fiberglass mounting plate – Labyrinth oil seals
– Certified clean room assembly • Tapered polygon impeller drive – Oil slinger
– Inpro/Seal VBXX isolators • Pullout bearing retainers – Regreasable or double
– Magnetic drain plug • Level controls shielded bearings
• Choice of shaft metallurgy – Oil mist lubrication
Related Configurations • Optional ANSI 3A power end with
• PolyChem VGRP engineered polymer Related Configurations lifetime warranty
composite sump • PolyChem GRP engineered polymer – Certified clean room assembly
• Self-primer composite – Inpro/Seal VBXX isolators
– Magnetic drain plug
See Bulletin PS-10-17 See Bulletin PS-10-17
14 See Bulletin PS-10-17
PolyChem M-Series Polyshield Baseplate Polybase
Fluoropolymer Lined, and Foundation System Polymer Concrete
Magnetic Drive Baseplate

Overhung – Chemical Process


Standards Standards Standards
• ASME (ANSI) B73.1 • Flowserve • ANSI and ISO standard designs
• ISO 2858
• JIS drilling Operating Parameters Features
• Temperatures to 260°C (500°F) • Solid polymer concrete construction
Operating Parameters • Low installed cost
• Flows to 135 m3/h (600 gpm) Features • Superior flatness
• Heads to 145 m (480 ft) • Combines non-metallic baseplate • Enhanced vibration dampening
• Pressures to 17 bar (250 psi) and formed concrete foundation for • Excellent corrosion resistance
• Temperatures from -30°C (-20°F) pump-driver in one complete unit • Outstanding resistance to twisting
to 150°C (300°F) • Excellent corrosion resistance or diaphragming
• Improved vibration dampening • 8-point™ adjuster alignment system
Features • Reduced installation costs and time • Choice of three polymer materials
• PFA-lined wet end • Solid one-piece polymer motor • Options
• Casing is ductile cast iron with mounting block with four 304 SS – Polybloc™ motor mounting blocks
3 mm (0.1 in) minimum PFA liner transverse motor block adjusters – Catch basin
thickness • Self-venting design with grout hole – Grout hole
• PFA-lined fiberglass containment shell and plug – Alternate equipment inserts
• Enclosed PFA-lined impeller • Standard 316 stainless steel inserts
• Rare earth magnets in • Integral catch basin with NPT See Bulletin PS-10-13
synchronous drive connection
• Metal armor meets material • Uses 200 bar (3000 psi) concrete
specifications of ASTM A395 • Suitable with ANSI, ISO, API and
and GGG40.3 other foot-mounted and centerline
• Separate inner magnet and impeller mounted pumps
components • Outstanding flatness
• Rotating shaft design • Options
• Silicon carbide radial and axial – Choice of three polymer materials
thrust bearings – Alloy 20 and Alloy C-276
• Choice of bearing lubrication inserts available
• Options – CPVC drain connection
– Long and close coupled designs
– ANSI 3A power end See Bulletin PS-90-2

See Bulletin PS-10-17

15
HPX (OH2) HPXM (OH2) PHL (OH2)
Centerline Mounted Centerline Mounted, Centerline Mounted
Low Flow
Overhung – API Process

Standards Standards Standards


• ISO 13709/API 610 (OH2), latest ed. • ISO 13709/API 610 (OH2), latest ed. • ISO 13709/API 610 (OH2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2000 m3/h (8800 gpm) • Flows to 30 m3/h (130 gpm) • Flows to 900 m3/h (4000 gpm)
• Heads to 350 m (1100 ft) • Heads to 280 m (920 ft) • Heads to 400 m (1300 ft)
• Pressures to 80 bar (1160 psi) • Pressures to 80 bar (1160 psi) • Pressures to 40 bar (600 psi)
• Temperatures from -160°C (-250°F) • Temperatures from -160°C (-250°F) • Temperatures from -160°C (-250°F)
to 450°C (840°F) to 450°C (840°F) to 450°C (840°F)
• Motor sizes to 110 kW (150 hp)
Features Features
• Centerline supported casing • Low flow, high head design Features
• Nozzle loading capability beyond • Replaceable volute inserts • Centerline supported, end
ISO 13709/API 610 requirements • High-efficiency patented design radial suction casing
• Dynamically balanced impeller blade impeller • Custom-tuned hydraulics
• Rugged shaft design • Full interchangeability with HPX bear- • Multi-channel diffuser technology
• ISO 21049/API 682 seal chamber ing assembly and mechanical seals −−Customized BEP fits
accommodates multiple seal types • Choice of bearings −−High efficiency
• Choice of bearings – Standard single row, deep groove, −−Extended MTBR
– Standard single row, deep groove, radial bearing and duplex, single row −−Low vibration
radial bearing and duplex, single row 40° angular contact thrust bearings −−Low noise
40° angular contact thrust bearings – Special bearing arrangements for • Low shaft deflection at any flow
– Special bearing arrangements for high suction pressures • ISO 21049/API 682 seal chamber
high suction pressures • ISO 21049/API 682 seal chamber accommodates multiple seal types
• Bearing lubrication and cooling options accommodates multiple seal types including dual pressurized,
– Oil mist and oil purge • Bearing lubrication and cooling unpressurized and gas
– Fan cooling options • Bearing housing cooling options
– Finned cooling insert – Oil mist and oil purge – Air fan
– Fan cooling – Water jacket
Related Configurations – Finned cooling insert • Replaceable diffusers
• HPXT centerline mounted, top suction • Optional inducer • Available boron diffusion
• HPXH centerline mounted, high surface treatment
suction pressure Related Configurations
• HPXSL centerline mounted, slurry • HPX centerline mounted Other Configurations
• HPXIND centerline mounted, inducer • Top suction nozzle
• HPXCC centerline mounted, See Bulletin PSS-10-5.1
coke crusher See Bulletin PSS-10-5.2
16 See Bulletin PS-10-5
ERPN PVXM (OH3) HWMA (OH3)
Centerline Mounted Vertical In-Line Vertical In-line, Low-Flow
High-Head

Overhung – API Process


Standards Standards Standards
• Flowserve • ISO 13709/API 610 (OH3), latest ed. • ISO 13709/API 610 (OH3), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1100 m3/h (4800 gpm) • Flows to 500 m3/h (2200 gpm) • Flows to 45 m3/h (200 gpm)
• Heads to 230 m (750 ft) • Heads to 275 m (900 ft) • Heads to 440 m (1455 ft)
• Pressures to 60 bar (870 psi) • Pressures to 40 bar (600 psi) • Pressures to 60 bar (870 psi)
• Temperatures to 350°C (660°F) • Temperatures from -100°C (-148°F) • Temperatures from -50°C (-58°F) to
to 250°C (480°F) 260°C (500°F)
Features
• Critical parameters meet Features Features
ISO 13709/API 610 (OH2) • Space saving design • Space saving design
– Vibration limits • Precision machined diffusers • Low-flow, high-head hydraulics
– Deflection limits at seal faces • Customizable hydraulics – 150 BEP • Replaceable volute inserts
– Nozzle loading capabilities hydraulic fits with 10 casings • Customizable hydraulics – 80 BEP fits
– Balancing grades • Casing and cover design with in a single pump size
• ISO 21049/API 682 seal chamber metal-to-metal fits and fully confined • Casing and cover design with metal-
accommodates multiple seal types compression gasket to-metal fits and fully confined
• Dynamically balanced, high- • ASME (ANSI) B16.5 Class 300 compression gasket
efficiency impeller raised face flanges • ASME (ANSI) B16.5 Class 600 raised
• Centerline supported casing • Dynamically balanced impeller face flanges; flat face optional
• Double volute design for discharge • Optimized NPSHr due to suction • Patented radial blade impeller
flanges 80 mm (3 in) and larger box design • Optional inducer for low NPSHr
• Renewable casing and cover • ISO 21049/API 682 seal chamber • ISO 21049/API 682 seal chamber
wear rings • Heavy-duty motor support head fits • Heavy-duty motor support head fits
• Back pullout design NEMA, C-Face and IEC drivers NEMA, C-Face, P-base and IEC drivers
• Optional inducer • 100% back pullout design • 100% back pullout design
• Choice of API materials • Flexible disc spacer coupling • Flexible disc spacer coupling
• Upper and lower labyrinth bearing • Upper labyrinth bearing isolator;
Related Configurations isolators; optional radial lip seals optional radial lip seals
• ERPN-O semi-open impeller • Bearing lubrication options • Choice of bearing lubrication systems
• High suction pressure: −−Oil cascade
35 bar (500 psi) −−Oil mist Related Configurations
−−Grease lube • WMA rigidly coupled, vertical in-line
See Bulletin PS-10-20 • HWMA2 two stage, vertical in-line
Related Configurations • WMA2 rigidly coupled, two stage,
• PVML vertical in-line vertical in-line

See Bulletin PS-10-29 See Bulletin PS-10-25 17


PVML (OH5) MSP DSVP (OH4)
Vertical In-Line Vertical In-Line, Vertical In-Line
Medium Speed
Overhung – API Process

Standards Standards Standards


• ISO 13709/API 610 (OH5), latest ed. • Flowserve • ISO 13709/API 610 (OH4), latest ed.
• BS 4082R
Operating Parameters Operating Parameters
Operating Parameters • Flows to 27 m3/h (120 gpm) • Flows to 3400 m3/h (15 000 gpm)
• Flows to 500 m3/h (2200 gpm) • Heads to 900 m (2955 ft) • Heads to 85 m (275 ft)
• Heads to 275 m (900 ft) • Pressures to 60 bar (870 psi) • Pressures to 40 bar (600 psi)
• Pressures to 40 bar (580 psi) • Maximum suction pressure to • Temperatures to 340°C (650°F)
• Temperatures from -100°C (-148°F) 40 bar (580 psi) • Motor ratings to 895 kW (1200 hp)
to 250°C (480°F) • Temperatures from -40°C (-40°F)
to 350°C (660°F) Features
Features • Speeds from 2000 rpm to 8000 rpm • Space-saving design
• Space-saving, alignment-free design • ISO 21049/API 682 seal chamber
• Custom-tuned hydraulics Features accommodates multiple seal types
• State-of-the-art diffuser technology • Closely follows ISO 13709/API 610 • Double suction enclosed impeller
−−Customized BEP fits (OH4), latest edition • Double volute case design
−−High efficiency • Modified concentric volute • Standard case wear rings
−−Extended MTBR • Open impeller with balance holes • Optional impeller wear rings
−−Low vibration and scallops • Metal-to-metal case to cover
−−Low noise • Variable frequency drive sealing with confined gasket
• ISO 21049/API 682 seal chamber • Rigid coupling • Rigid spacer type coupling
accommodates multiple seal types • Single or dual cartridge • Impeller nut design, threaded
• Dynamically balanced impeller mechanical seals to tighten with rotation
• Positively locked, anti-rotation • Options
impeller nut with threads unexposed – Inducer
to pumped fluid – Choice of materials

Related Configurations Available Configurations


• PVXM vertical in-line • Horizontal configuration
• MSP vertical in-line, single stage
See Bulletin PS-10-28 • MSP2 vertical in-line, two stage
(opposed impellers)

See Bulletin PS-10-1

18
M R Titan Slurry
Hard Metal, Radially Split, Heavy-Duty,
Abrasive Slurry Rubber Lined Slurry Radially Split, Lined

Overhung – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 10 000 m3/h (44 000 gpm) • Flows to 10 000 m3/h (44 000 gpm) • Flows to 3600 m3/h (16 000 gpm)
• Heads to 90 m (300 ft) • Heads to 50 m (165 ft) • Heads to 90 m (300 ft)
• Pressures to 10 bar (150 psi); • Pressures to 10 bar (150 psi) • Pressures to 40 bar (580 psi)
50 bar (725 psi) with the high standard; 35 bar (510 psi) optional • Sizes from 50 mm (2 in)
pressure model • Temperatures to 110°C (225°F) to 350 mm (14 in)
• Temperatures to 120°C (250°F) • Solids from 2% to 70% by weight
• Solids from 2% to 70% by weight Features
Features • Fully interchangeable elastomeric
Features • Concentric, cast iron casing with or hard metal liners
• One-piece high chrome iron, replaceable, abrasion-resistant • Radially split casing
concentric casing with replaceable rubber liner • High-efficiency, closed impeller
gland and suction side wear plates • Rubber lined, closed impeller with • Ample seal chamber accommodates
• Closed impeller with pump-out vanes front and rear pump-out vanes a variety of packing and seal types
on front and rear shrouds • Standard packing type stuffing box • Heavy-duty bearing frame sized
• Standard packing-type stuffing box with replaceable wear plate to handle belt loads
with replaceable wear plate • Full and low flow flush connections • Bearing cartridge with back-to-back
• Full and low flow flush connections • Heavy-duty bearing frame angular contact thrust bearings
• Heavy-duty bearing frame • Three-point, external end clearance • Roller type radial bearings
designed for V-belt loads adjustment • Contact lip seals
• Cartridge style bearings • Parts interchangeable with M pump • Dimensionally compatible with the
• Parts interchangeable with R pump • Directly coupled or V-belt driven industry’s most widely used pumps
• Three-point external end • Options • Optional expeller for dynamic sealing
clearance adjustment – Acid-resistant stuffing box kits
• Options – Hard metal expeller Available Configurations
– Vortex semi-recessed impeller – Mechanical seal housing • Metal lined model
– Hard metal expeller – Choice of liner materials • Rubber lined model
– Mechanical seal housing • High-pressure model
Related Configurations
Related Configurations • RJ rubber lined, slurry sump See Bulletin PS-10-8
• Severe-duty model • RJC cantilever rubber lined,
• High-pressure model slurry sump
• MJ slurry sump
• MJC cantilever slurry sump See Bulletin PS-10-18

See Bulletin PS-10-19 19


LC MND MNR
Chemical Slurry Hard Metal Rubber Lined
Absorber Recirculation Absorber Recirculation
Overhung – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 8000 m3/h (35 200 gpm) • Flows to 17 500 m3/h (77 000 gpm) • Flows to 17 500 m3/h (77 000 gpm)
• Heads to 90 m (300 ft) • Heads to 40 m (130 ft) • Heads to 40 m (130 ft)
• Pressures to 25 bar (360 psi) • Sizes from 600 mm (24 in) to • Sizes from 600 mm (24 in) to
• Temperatures to 140°C (285°F) 1000 mm (40 in) 1000 mm (40 in)
• Specific gravities to 1.7
Features Features
Features • One-piece, high-efficiency impeller • One-piece, high-efficiency impeller
• Concentric casing with tangential with mixed flow vane design with mixed flow vane design
discharge • Multiple materials of construction • Removable one-piece elastomeric
• Rigid, one-piece bearing frame • Replaceable casing wear ring casing liner
with two angular contact outboard • Opposed tapered roller bearings • Radially split casing
bearings and roller inboard bearings designed for a minimum B10 life • Multiple materials of construction
• Large diameter, heavy-duty shaft of 100 000 hours • Replaceable casing wear ring
• Choice of shaft sealing options • Product flush slurry seal • Opposed tapered roller bearings
– Wet gland packing • External end clearance adjustment designed for a minimum B10 life
– Single or double mechanical seal • Front and back pullout of 100 000 hours
– High-pressure double • Product flush slurry seal
mechanical seal Related Configurations • External end clearance adjustment
– Special high solids seals • Vertical mounting • Front and back pullout
– Alumina industry seal • MNR rubber lined absorber
• Choice of materials of construction recirculation Related Configurations
• Multiple impeller designs • Vertical mounting
• Direct coupled or belt driven See Bulletin PS-10-32 • MND hard metal absorber
• Choice of six drive arrangements recirculation
• Options
– Inducer See Bulletin PS-10-32
– Stuffing box cooling system

Related Configurations
• PL-C cantilever, chemical
slurry sump
• LC-S lineshaft, chemical
slurry sump
20 See Bulletin PS-10-11
FRBH FRBHJC MPT
Heavy-Duty Paper Stock Cantilever Sump Self-Priming,
and Process Solids Handling

Overhung – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 9085 m3/h (40 000 gpm) • Flows to 2700 m3/h (12 000 gpm) • Flows to 600 m3/h (2650 gpm)
• Heads to 100 m (330 ft) • Heads to 100 m (330 ft) • Heads to 35 m (115 ft)
• Pressures to 14 bar (200 psi) • Temperatures to 150°C (300°F) • Temperatures to 75°C (165°F)
• Temperatures to 150°C (300°F) • Speeds to 1780 rpm • Working pressures to 5 bar (72 psi)
• Sizes 50 to 200 mm (2 to 8 in)
Features Features • Solids to 75 mm (3 in) diameter
• Self-venting, top centerline • True stiff shaft cantilever design,
discharge casing without bottom bearing or Features
• Semi-open, full vane impeller with flushing water • Two-vane, semi-open, solids
back pump-out vanes • Steep head-capacity handling impeller
• Large suction inlet • Semi-open, full vane impeller with • External impeller adjustment
• Seal chamber accepts packing or back pump-out vanes • Abrasion-resistant double
mechanical seal • Direct coupled or V-belt driven mechanical seal
• Three-point end clearance adjustment • Extra heavy-duty alloy steel shaft • Quick-disconnect cover plate
• Back pullout design • Heavy-duty, volute casing
• Heavy-duty, oil-lubricated bearings Related Configurations • Replaceable seal housing
• Fully split interlocking glands • FRBH heavy-duty paper stock • Replaceable and reversible
• Extra heavy-duty alloy steel shaft and process wear plate
• Contoured wearplate match • FRBHJ vertical lineshaft sump • Solid one-piece flap valve
machined with impeller • Back pullout design
• Dry shaft construction with sealed See Bulletin PS-10-16 • Multiple drive options
impeller nut and stainless steel • Extra large diameter shaft
hook sleeve
• Rigid, one-piece bearing frame See Bulletin PS-10-9
• Options
– Large conical seal housing
– Inducer
– Expeller
– Recessed impeller

Related Configurations
• FRBHJC cantilever sump
• FRBHJ sump

See Bulletin PS-10-16 21


MF MN MSX
Solids Handling Large Capacity, Solids Handling,
Solids Handling Submersible
Overhung – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2275 m3/h (10 000 gpm) • Flows to 45 500 m3/h (200 000 gpm) • Flows to 4545 m3/h (20 000 gpm)
• Heads to 90 m (300 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes to 400 mm (16 in) • Sizes to 1800 mm (72 in) • Temperatures to 40°C (104°F)
• Discharge sizes from 80 mm (3 in)
Features Features to 500 mm (20 in)
• Variety of nozzle position options • Variety of nozzle position options • Motor to 224 kW (300 hp)
• Direct or independent motor mounting • Direct or independent motor mounting • Solids handling to 80 mm (3 in)
• Minimal shaft deflection • Minimal shaft deflection diameter spherical
• Oversized shaft and reduced overhang • Oversized shaft and reduced overhang
• Hardened chrome steel wear rings • Hardened chrome steel wear rings Features
• Seal chamber accommodates packing • Seal chamber accommodates packing • High-efficiency hydraulics
or mechanical seals or mechanical seals • EPACT rated motor
• Adjustable impeller clearance • Adjustable wear ring clearance • Spike-resistant windings
• Shaft sleeve options • Shaft sleeve options • Class H rated insulation system
– 316 stainless steel – 316 stainless steel • Dynamically balanced shaft
– Hardened chrome steel – Hardened chrome steel and rotor
• Bearing housing features • Bearing housing features • Mounting options
– Ball or tapered roller bearings – Tapered roller bearings – Wet pit
– Integral jacking bolts for wear – Integral jacking bolts for wear – Dry pit
ring adjustment ring adjustment – Transportable
– Accessible lubrication points – Accessible lubrication points
Available Configurations
Available Configurations Available Configurations • MSX Series 1: Sizes from
• MF horizontal, end suction • MN horizontal, end suction 75 mm (3 in) to 150 mm (6 in)
• MFV vertical with motor on • MNF vertical, bottom suction, direct • MSX Series 2/3: Sizes to
separate floor (shown) connected motor 500 mm (20 in)
• MFC vertical with direct connected • MNZ vertical, bottom suction, motor
motor on separate floor See Bulletin PS-50-2
• MNC vertical with base elbow, direct
See Bulletin PS-10-3 connected motor
• MNV vertical with base elbow, motor
on separate floor (shown)

See Bulletin PS-10-4


22
D800 Series MEN MENBloc
Cast Iron End Suction Close Coupled

Overhung – Industrial Process


Standards Standards Standards
• Flowserve • DIN 24255 • DIN 24255
• EN 733 • EN 733
Operating Parameters • Flowserve • Flowserve
• Flows to 340 m3/h (1500 gpm)
• Heads to 120 m (395 ft) Operating Parameters Operating Parameters
• Pressures to 15 bar (220 psi) • Flows to 800 m3/h (3520 gpm) • Flows to 340 m3/h (1500 gpm)
• Temperatures to 120°C (250°F) • Heads to 140 m (450 ft) • Heads to 100 m (330 ft)
• Pressures to 16 bar (230 psi) • Pressures to 16 bar (230 psi)
Features • Temperatures to 120°C (250°F) • Temperatures to 110°C (230°F)
• High-efficiency closed impeller
• Centerline discharge Features Features
• Sealed-for-life, pre-lubricated motor • 33 sizes available • Compact, space-saving configuration
bearings with two-year minimum life • Volute casing with top discharge • End suction, top discharge,
• Renewable wear rings and shaft • Dynamically balanced, precision cast volute casing
sleeves closed impeller with extended hub • Precision cast and dynamically
• Pre-set mechanical seal assembly and machined shroud balanced high-efficiency, closed
• Bell type mechanical seal cover • Balancing chamber and impeller impeller with extended hub
• Standard NEMA C-face motor balance holes minimize axial thrust • Impeller balance chamber and holes
• Back pullout design • Open seal chamber with integral for reduced thrust
• Threaded and flanged connections vortex breaking ribs • Open seal chamber with integral
• Oversized stainless steel shaft vortex breaking ribs
Available Configurations • Oversized bearings • Oversized stainless steel shaft
• Type D-814 frame mounted • Standard case wear rings • Oversized bearings
• Type D-824 close coupled • Back pullout design • Standard case wear rings
• Type D-834 vertical in-line • Back pullout design
Related Configurations • Baseplate and coupling not required
See Bulletin PS-10-6 • MEN-SP vertical cantilever sump • CE marked in Europe
• MHP high-pressure
• MENBLOC close coupled Related Configurations
• ME horizontal high capacity • MEN horizontal end suction
• MEV vertical high capacity • MEN-SP vertical cantilever sump
• MHP high-pressure
See Bulletin PS-10-2 • ME horizontal high capacity
• MEV vertical high capacity

See Bulletin PS-10-2


23
ME DS SMP
End Suction Double Volute, Standard Motor
End Suction
Overhung – Industrial Process

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 3000 m3/h (13 200 gpm) • Flows to 5700 m3/h (25 000 gpm) • Flows to 135 m3/h (600 gpm)
• Heads to 90 m (295 ft) • Heads to 110 m (350 ft) • Heads to 70 m (220 ft)
• Pressures from 4 to 16 bar • Pressures to 27 bar (400 psi) • Pressures to 12 bar (175 psi)
(58 to 232 psi) • Temperatures to 120°C (250°F) • Temperatures from -40°C (-40°F)
• Temperatures to 120°C (250°F) to 120°C (250°F)
Features
Features • Double volute, end suction casing Features
• Single volute, end suction casing with centerline discharge • Glass reinforced polymer, high-
with tangential discharge • Mechanically balanced, radial flow efficiency, semi-open or closed
• Back pullout design impeller impellers standard
• Radial flow impeller shrouded, • Impeller balance holes minimize • Industry standard NEMA motors
keyed on shaft axial thrust • Stainless steel, self-aligned
• Impeller balance holes minimize • Seal chamber accommodates packing mechanical seal
axial thrust and multiple mechanical seal types • Back pullout design
• Bearings • Back pullout design • Clamp-type mounting plate
−−Radial ball bearing and roller • Angular contact thrust bearing and • Options
bearings (depending on size) parallel roller radial bearing – Cast iron, bronze or 316 stainless
−−Sealed for life for lower frames, • Grease lubrication standard; oil steel impellers
rationalized with MEN sizes lubrication optional – Stub shaft design
−−Grease lubricated for higher frames • Choice of materials – from cast iron
to super duplex Related Configurations
Related Configurations • SMX non-metallic, standard
• MEV vertical, end suction Related Configurations motor pump
• MEN horizontal, end suction • DSV vertical • VSMP vertical, standard
(low capacity) • Directional discharge motor pump
• MHP horizontal, end suction (90° on the right or on the left)
(low capacity, high-pressure) • Centerline mounted See Bulletin PS-10-26
• DS horizontal, end suction
(high capacity)

24
SMX F-Line MVE
Non-Metallic End Suction, Multistage End Suction
Standard Motor

Overhung – Industrial Process


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 25 m3/h (100 gpm) • Flows to 500 m3/h (2200 gpm) • Flows to 2700 m3/h (11 890 gpm)
• Heads to 20 m (60 ft) • Heads to 250 m (820 ft) • Heads to 15 m (50 ft)
• Pressures to 12 bar (175 psi) • Discharge pressures to 25 bar • Pressures to 7 bar (100 psi)
• Temperatures to 80°C (180°F) (365 psi) • Temperatures to 100°C (212°F)
• Temperatures to 105°C (220°F)
Features Features
• Polyphenylene sulfide (PPS) casing, Features • Single volute casing with end
adapter and impeller • Modular design suction and side discharge;
• Standard NEMA 56J frame – 8 sizes top discharge optional
C-faced motor – 15 hydraulics • Mechanically balanced, mixed
• Stainless steel, self-aligned – 2 impeller types flow impeller
mechanical seal • To 9 stages, depending on model • Seal chamber accommodates packing
• Back pullout design and operating speed and multiple mechanical seal types
• 40 mm (1.5 in) port size for hose • Sleeved shaft under sealing system • Back pullout design
connection • Cast iron EN-GJL 250 pressure • Standard angular contact radial and
casings thrust bearings
Related Configurations • Cast iron EN-GJL 250 or Noryl® • Standard grease lubrication; oil
• SMP standard motor pump impellers, depending upon model lubrication optional
• VSMP vertical standard motor pump • Steel grade C 35 E shaft • Choice of materials
• 13% chromium steel sleeve −−Cast iron
See Bulletin PS-10-26 −−Ni-Resist®
Available Configurations −−Bronze
• FP horizontal, overhung impeller −−Super duplex stainless steel
• FM horizontal, close coupled
® N-Resist is a registered trademark of the International
• FD vertical Nickel Co., Inc.
• FS vertical, suspended shaft wet-pit
• FMD vertical, close coupled
• FAD vertical, rigid coupled
® Noryl is a registered trademark of General Electric Company

25
Between Bearings Pumps
Single Case - Axially Split -
Single Stage
LR 28
LNN 28

Between Bearings Pumps


DVSH 28
LPN 29
Single Case - Axially Split -
Multistage
EC 30
UZDL 30
DMX 30
Single Case - Radially Split -
Single Stage
HDX 31
HDX-TT 31
DVSR 31
Single Case - Radially Split -
Multistage
HED 32
HED-DS 32
WTB 32
WD 33
WDX 33
NM 33
WX 33
CS 34
WXH 34
Double Case
WXB 35
WXB-B 35
WNC 35
CSB 35
CHTA 36
HDB 36
HSB 36
BP 36
WCC 37
HDO 37
HSO 37
WIK 37
WIKO 37

27
LR LNN DVSH (BB1)
Axially Split, Single Stage Axially Split, Single Stage Axially Split, Single Stage
OverhungBearings
Between – General
– Industry
Single Case - Axially Split - Single Stage

Standards Standards Standards


• Flowserve • Flowserve • ISO 13709/API 610 (BB1), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2000 m3/h (8800 gpm) • Flows to 30 000 m3/h (132 000 gpm) • Flows to 12 000 m3/h (52 835 gpm)
• Heads to 170 m (560 ft) • Heads to 300 m (980 ft) • Heads to 565 m (1854 ft)
• Pressures to 21 bar (300 psi) • Pressures to 40 bar (580 psi) • Pressures to 150 bar (2175 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 140°C (285°F) • Temperatures to 200°C (400°F)
to 150°C (300°F) • Speeds to 6000 rpm
Features
Features • Heavy-duty, double volute casing Features
• Split case design with lifting lugs with side suction and side discharge • Double volute casing
• Low NPSH enclosed double • Flanges to ANSI, DIN and • Hydraulically balanced double
suction impeller ISO standards suction impeller
• Flat or raised face suction and • Hydraulically balanced, double • ISO 21049/API 682 seal chambers
discharge flanges to ANSI, DIN and suction impeller accommodates multiple seal types
ISO standards • Optimum axial and radial • Stiff shaft design
• Oil or grease lubricated radial and thrust balance • Baseplate designs and pump
thrust bearings • Standard casing wear rings; optional packages engineered to contract
– Single row, deep groove ball bear- impeller wear rings requirements
ings or duplex thrust ball bearings • Seal chamber accommodates packing • Choice of bearings
– 100 000 hours typical L10 and multiple mechanical seal types – Ball radial and thrust
bearing life • 360° supported bearing housing – Sleeve radial and ball thrust
• Seal chamber accommodates • Choice of bearings – Sleeve radial and tilting pad thrust
multiple seal types −−Standard ball radial and ball thrust • Choice of materials
• Standard case wear rings; optional −−Optional double row, angular −−Carbon steel
serrated groove designs contact thrust bearings −−12% chrome
• Optional impeller wear rings −−Optional sleeve bearings −−Austenitic stainless steels
• Available high performance coatings • Grease lubrication standard; oil mist −−Duplex stainless steels
and bath optional
Related Configurations • Choice of materials See Bulletin PS-20-2
• LRV vertical, axially split,
single stage Related Configurations
• LLR axially split, two stage • LNNV vertical, single stage
• LNNC single stage, bottom suction
See Bulletin PS-20-3 • LNE, LNS, LNST and LNGT axially
split, single stage
28 See Bulletin PS-20-1
LPN (BB1)
Axially Split, Double
Suction, Single Stage

OverhungBearings
Between – General
– Industry
Single Case - Axially Split - Single Stage
Standards
• ISO 13709/API 610 (BB1), latest ed.

Operating Parameters
• Flows to 15 000 m3/h (65 000 gpm)
• Heads to 250 m (820 ft)
• Pressures to 25 bar (365 psi); 50 bar
(725 psi) with LPN-H model
• Temperatures from -80°C (-110°F)
to 150°C (400°F)

Features
• Double volute, near-centerline
supported casing
• ASME (ANSI) B16.5 Class 150 or
Class 300 raised face flanges
• Confined gasket design
• Hydraulically balanced double
suction impeller
• ISO 21049/API 682 seal chambers
• Baseplate designs and pump
packages engineered to contract
• Heavy-duty, bracketed, 180°
supported carbon steel bearing
housing
• Standard non-contacting labyrinth seals
• Choice of bearings
−−Ball radial and ball thrust with oil
flinger system
−−Split leeve radial and ball thrust
with ring oil system
−−Split sleeve radial and tilting pad
thrust with pressure lubrication

Other Configurations
• LPN-H high-pressure, double suction
• LPN-V vertical in-line

See Bulletin PS-20-5 29


EC UZDL (BB1) DMX (BB3)
Axially Split, Multistage Axially Split, Two Stage Axially Split, Multistage
OverhungBearings
Between – General
– Industry
Single Case - Axially Split - Multistage

Standards Standards Standards


• Flowserve • ISO 13709/API 610 (BB1), latest ed. • ISO 13709/API 610 (BB1), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2340 m3/h (10 300 gpm) • Flows to 2950 m3/h (13 000 gpm) • Flows to 2950 m3/h (13 000 gpm)
• Heads to 650 m (2130 ft) • Heads to 685 m (2250 ft) • Heads to 2130 m (7000 ft)
• Pressures to 88 bar (1300 psi) • Pressures to 64 bar (910 psi) • Pressures to 275 bar (4000 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 200°C (400°F) • Temperatures to 200°C (400°F)
to 150°C (300°F) • Speeds to 2000 rpm • Speeds to 6000 rpm

Features Features Features


• Horizontally split case with integral • Double volute hydraulic passages • Double volute hydraulic passages
mounting feet • ISO 21049/API 682 seal chambers • Renewable case and impeller
• In-line mounted impellers • Shaft options wear rings
• Rotating assembly balanced as a unit – Double extension for connection • ISO 21049/API 682 seal chambers
• Case wear rings standard at to auxiliary pumps or hydraulic • Axially split center bushing
impeller eye turbines • Shaft options
• Diaphragm rings standard at impeller – Special shaft end machining for – Double extension for connection
back shroud hydraulic fitted couplings to auxiliary pumps or hydraulic
• Shaft protected by interstage sleeves • Baseplate designs and pump turbines
and packing sleeves packages engineered to contract – Special shaft end machining
• Seal chambers can accommodate • Dynamic balancing and TIR for hydraulic fitted couplings
packing or mechanical seals verifications on assembled rotors • Interstage take-off option
• Double row anti-friction radial and • Choice of bearings • Baseplate designs and pump
thrust bearings – Ball radial and thrust packages engineered to contract
• Grease lubrication – Sleeve radial and ball thrust • Dynamic balancing and TIR
– Sleeve radial and tilting pad thrust verifications on assembled rotors
– Tilting pad radial and tilting • Choice of bearings
pad thrust – Ball radial and thrust
• Choice of materials – Sleeve radial and ball thrust
– Carbon steel – Sleeve radial and tilting pad thrust
– 12% chrome • Choice of bearing lubrication systems
– Austenitic stainless steels • Choice of bearing cooling systems
−−Duplex stainless steels • Choice of materials
– Monel®
See Bulletin PS-30-3
See Bulletin PS-30-2
30 ® Monel is a registered trademark of International Nickel Co.
HDX (BB2) HDX-TT (BB2) DVSR
Radially Split, Radially Split, Power Radially Split, Volute
Double Suction Recovery Turbine Casing, Single Stage

OverhungBearings
Between – General
– Industry
Single Case - Radially Split - Single Stage
Standards Standards Standards
• ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4100 m3/h (18 000 gpm) • Flows to 4100 m3/h (18 000 gpm) • Flows to 3635 m3/h (16 000 gpm)
• Heads to 450 m (1500 ft) • Heads to 760 m (2500 ft) • Heads to 250 m (820 ft)
• Pressures to 42 bar (610 psi); • Pressures to 100 bar (1450 psi) • Pressures to 260 bar (3750 psi)
100 bar (1450 psi) with HDX-H model • Temperatures to 450°C (850°F) • Temperatures to 200°C (400°F)
• Temperatures to 450°C (850°F) • Speeds to 4000 rpm
Features
Features • Double volute, centerline supported, Features
• Double-volute, centerline supported, self-venting casing with diffuser • Double volute casing
self-venting casing • ASME (ANSI) B16.5 Class 300 • Hydraulically balanced double
• ASME (ANSI) B16.5 Class 300 flanges; optional Class 600 and suction impeller
flanges; optional Class 600 and 900 flanges • Staggered vane impellers
900 flanges • Dynamically balanced, double • Stiff shaft design
• Dynamically balanced, double suction, radial inflow turbine runner • IS0 21049/API 682 seal chambers
suction impeller • Stiff shaft design • Baseplate designs and pump packages
• Stiff shaft design • ISO 21049/API 682 seal chambers engineered to contract
• ISO 21049/API 682 seal chambers • Standard dual, single-row, back-to- • Choice of bearings
• Standard dual, single-row, back-to- back mounted, angular contact type −−Sleeve radial and ball thrust
back mounted, angular contact type thrust bearing −−Sleeve radial and tilting pad thrust
thrust bearing • Bearing options −−Tilting pad radial and tilting
• Bearing options – Sleeve radial and ball thrust pad thrust
– Sleeve radial and ball thrust – Sleeve radial and tilting pad thrust • Choice of materials
– Sleeve radial and tilting pad thrust – Lubrication systems available −−Carbon steel
– Lubrication systems available • 360° supported bearing housing −−12% chrome
• 360° supported bearing housing • Double case covers
• Double case covers
Other Configurations
Related Configurations • High-pressure
• HDX-H high-pressure, radially split, • In-line side nozzles
double suction • Side-side nozzles (90° rotated)
• In-line side nozzles
• Same-side nozzles (90° rotated)

See Bulletin PS-20-4


31
HED (BB2) HED-DS (BB2) WTB (BB2)
Radially Split, Two Stage Radially Split, Double Radially Split, Double
Suction, Two Stage Suction, Three Stage
OverhungBearings
Between – General
– Industry
Single Case - Radially Split - Multistage

Standards Standards Standards


• ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed. • ISO 13709/API 610 (BB2), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1000 m3/h (4400 gpm) • Flows to 2000 m3/h (8800 gpm) • Flows to 1400 m3/h (6165 gpm)
• Heads to 650 m (2100 ft) • Heads to 750 m (2460 ft) • Heads to 1100 m (3610 ft)
• Pressures to 120 bar (1750 psi) • Pressures to 120 bar (1750 psi) • Pressures to 108 bar (1565 psi)
• Temperatures to 450°C (850°F) • Temperatures to 450°C (850°F) • Temperatures to 430°C (800°F)
• Speeds to 3600 rpm
Features Features
• Heavy-duty, double volute casing • Double suction first stage impeller Features
with 180° staggered volutes • Heavy-duty, double volute casing • Meets intent of key ISO/API
• Top-top nozzle configuration with 180° staggered volutes requirements
• ISO 13709/API 682 seal chambers • Top-top nozzle configuration • Heavy-duty, centerline supported, dual
• Dynamic balancing and TIR • ISO 13709/API 682 seal chambers volute casing with integral crossover
verifications on assembled • Dynamic balancing and TIR • ASME (ANSI) B16.5 Class 300 flanges;
rotating element verifications on assembled Class 600 and 900 flanges optional
• Baseplate designs and pump packages rotating element • Dynamically balanced, double suction
engineered to contract • Baseplate designs and pump first stage impeller; single suction on
• Choice of bearings packages engineered to contract smallest three-stage only
– Ball radial and thrust • Choice of bearings • Balance holes on second and third
– Sleeve radial and ball thrust – Ball radial and thrust stage impellers
– Sleeve radial and tilting pad thrust – Sleeve radial and ball thrust • IS0 21049/API 682 seal chambers
• Choice of materials – Sleeve radial and tilting pad thrust • 360° supported, carbon steel
– Carbon steel • Choice of materials bearing housing
– 12% chrome – Carbon steel • Choice of bearings
−−Austenitic stainless steel – 12% chrome −−Sleeve radial and ball thrust
−−Duplex stainless steel −−Austenitic stainless steel −−Sleeve radial and tilting pad thrust
−−Monel lining −−Duplex stainless steel −−Dual, single row, angular contact
−−Monel lining anti-friction thrust bearings installed
Other Configurations back-to-back and single row, deep
• HED-DS radially split, double suction, Other Configurations groove anti-friction radial bearing
two stage • HED radially split, two stage
• In-line side nozzles • In-line side nozzles Available Configurations
• Same-side nozzles • Same-side nozzles • WTB three stage, double suction
• High-pressure • High-pressure • WTB two stage, single suction
• WTB two stage, double suction
See Bulletin PS-30-4 See Bulletin PS-30-4
32 See Bulletin PS-30-14
WD and WDX NM WX
Radially Split, Multistage, Radially Split, Radially Split,
Ring Section Multistage, Ring Section Multistage, Ring Section

OverhungBearings
Between – General
– Industry
Single Case - Radially Split - Multistage
Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 190 m3/h (800 gpm) • Flows to 3 000 m3/h (13 210 gpm) • Flows to 300 m3/h (1320 gpm)
• Heads to 700 m (2300 ft) • Heads to 500 m (1640 ft) • Heads to 1200 m (3940 ft)
• Pressures to 75 bar (1090 psi) • Pressures to 60 bar (870 psi) • Pressures to 150 bar (2175 psi)
• Temperatures to 210°C (410°F) • Temperatures to 140°C (285°F) • Temperature from -50°C (-58°F) to
200°C (400°F)
Features Features
• Multivane diffusers • Modular design Features
• Identical radially-split ring – 15 sizes • Separate cast diffusers and
section sets – 22 hydraulics channel rings
• O-ring interstage sealing • Low NPSH suction volute design • Centerline mounted, self-venting
arrangement • Machined impeller shrouds for casing
• Deep-groove ball bearing design increased efficiency • Top/top nozzles
• Angular contact, double row • Impeller balance holes minimize • Interstage O-ring seals
thrust bearing axial thrust • Individual impeller balance
• 360° machine registered bearing • Shrouded diffusers with return guide • Precision fit rotor
housing fits vanes minimize radial thrust • Optional inducer for low NPSHr
• Dynamically balanced, precision • Removable seal housings
machined enclosed impellers accommodate gland packing and
• Packing or mechanical sealing mechanical seals
• Options • Standard cast iron construction;
– Multiple flange orientations high alloy construction available
– End suction design with product
lubricated sleeve bearing Other Configurations
– Radial suction design with product • NMV vertical, multistage ring section
lubricated sleeve bearing • NMD vertical, multistage ring section
– Inducer • NM-S vertical, suspended shaft
wet pit
• NMAD vertical, rigid shaft coupling

33
CS WXH
Radially Split, Radially Split, Multistage,
Multistage, Ring Section High Pressure,
Ring Section
OverhungBearings
Between – General
– Industry
Single Case - Radially Split - Multistage

Standards Standards
• Flowserve • Flowserve

Operating Parameters Operating Parameters


• Flows to 450 m3/h (1980 gpm) • Flows to 900 m3/h (4000 gpm)
• Heads to 1250 m (4110 ft) • Heads to 2650 m (8700 ft)
• Pressures to 125 bar (1800 psi) • Pressures to 250 bar (3625 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 250°C (480°F)
to 120°C (248°F)
Features
Features • Cast suction and discharge heads
• Separate cast diffusers and with integral nozzles
channel rings • Single or double suction first stage
• Secondary O-ring seals impeller designs
• Complete radial balance • Investment cast diffusers and return
• Press fit stationary wear parts channel hydraulic passages
• Balance disc wear indicator • Compression type interstage O-ring
• Disc balancing device • Separate, high strength sub-base
• Centerline or foot mounted casing • Replaceable stationary wear parts
• Optional nozzle orientation mounted in the diffusers
• Choice of bearings • Standard flanged balance drum with
– Ball radial and thrust serrated running clearances; optional
– Sleeve radial and ball thrust straight balance drum
– Sleeve radial and tilting • Seal chamber accepts single, double
pad thrust and tandem mechanical seals
• Large diameter shaft with staggered
impeller and balancing device keyways
• No pre-warming required
• Chrome steel nozzles
• Choice of bearings
−−Ball radial and thrust
−−Sleeve radial and ball thrust
−−Sleeve radial and tilting pad thrust

See Bulletin PS-30-1

34
WXB and WXB-B WNC CSB
Diffuser Casing, Diffuser Casing, Diffuser Casing,
Multistage, Process Barrel Multistage, Utility Barrel Multistage, Utility Barrel

OverhungBearings
Between – General
– Industry
Double Case
Standards Standards Standards
• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 300 m3/h (1320 gpm) • Flows to 1400 m3/h (6200 gpm) • Flows to 1500 m3/h (6600 gpm)
• Heads to 1200 m (3940 ft) • Pressures to 350 bar (5075 psi) • Discharge pressures to 300 bar
• Pressures to 150 bar (2175 psi) • Temperatures to 200°C (390°F) (4350 psi)
• Temperatures to 200°C (390°F) • Temperatures to 250°C (480°F)
Features • Speeds to 8000 rpm
Features • Diffuser case construction
• Diffuser case construction • Shear ring design Features
• Removeable cartridge type • High-strength forged steel barrel; • Internal casing with segmented
inner case sub-assembly alloy barrels available stage elements
• Large eye first stage impeller • Removable cartridge type • Diffuser-guide vane construction
• Low flow high head Barske impeller inner case sub-assembly • Precision cast in-line impellers of
on WXB-B • Shear ring barrel closing system high-quality chrome steel
• Patented balancing device • Single or double suction first • Heavy-duty barrel with forged steel
• Sleeve mounted deep groove radial stage impeller discharge cover
and back-to-back mounted angular • Standard antifriction or sleeve type • Fully enclosed or shrouded precision
contact bearings radial bearings cast diffusers on high-energy
• High-capacity, antifriction type • High-capacity antifriction type applications
thrust bearing thrust bearing; tilting pad thrust • Tilt pad thrust and tri-land
• Bearing lubrication system with bearing available radial bearings
oil bath, constant level oiler and • Renewable casing rings • Renewable casing rings and sleeves
sight glass • Straight balance drum forged from • Flanged balance drum forged from
• Renewable casing and impeller rings hardened stainless steel hardened stainless steel; straight
• High shaft diameter/bearing span ratio • Chrome plated shafting under drum optional
• Options journal bearings • Chrome plated shafting under
– Hydrodynamic sleeve type • Ground forged steel shafting journal bearings
radial bearings • Ground forged steel shafting
– Thrust bearing cooling system (air) Related Configurations
– Labyrinth type end seals • WNC-HP high-pressure, diffuser See Bulletin PS-30-12
casing, multistage, utility barrel
Available Configurations
• WXB: standard hydraulics See Bulletin PS-30-12
• WXB-B: low flow, high head hydraulics

See Bulletins PS-30-6 and PSS-30-6.1


35
CHTA HDB and HSB BP (BB5)
Diffuser Casing, Volute Casing, Diffuser Casing,
Multistage, Utility Barrel Multistage, Utility Barrel Multistage, Process Barrel
OverhungBearings
Between – General
– Industry
Double Case

Standards Standards Standards


• ASME Section VIII • ASME Section VIII • ISO 13709/API 610 (BB5), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 5250 m3/h (23 000 gpm) • Flows to 4000 m3/h (17 600 gpm) • Flows to 1050 m3/h (4620 gpm)
• Heads to 4300 m (14 000 ft) • Heads to 4300 m (14 000 ft) • Heads to 3500 m (11 480 ft)
• Discharge pressures to 450 bar • Discharge pressures to 450 bar • Discharge pressures to 295 bar
(6525 psi) (6525 psi) (4260 psi)
• Temperatures to 250°C (480°F) • Temperatures to 425°C (800°F) • Temperatures to 425°C (800°F)
• Speeds to 6000 rpm • Speeds to 9000 rpm • Speeds to 6000 rpm

Features Features Features


• Internal casing with segmented • Axially split inner casing • Diffuser, guide-vane style inner casing
stage elements • Dual volute design with symmetrical with segmented stage elements
• Diffuser-guide vane construction upper and lower halves • Inner casing bolted head at one end
• Precision cast in-line impellers • Opposed impellers • Heavy-duty barrel with forged steel
of high-quality chrome steel • Heavy-duty forged steel barrel discharge cover
• Heavy-duty barrel with forged steel and discharge cover • Multi-vane diffuser and channel
discharge cover • Individually mounted and secured ring design
• Fully enclosed or shrouded impellers • Precision cast diffusers
precision cast diffusers on high- • Dynamic balancing and TIR • Precision cast keyed impellers;
energy applications verifications on assembled rotor optional shrink fit impellers for high-
• Balance drum and sleeve made from • One full pressure sealing to speed or high-temperature service
hardened stainless steel forgings atmosphere and one full pressure • Single or double suction first stage
• Tilt pad thrust and tri-land sealing to suction impeller
radial bearings • Minimal pressure breakdowns • Straight style balance drum
• Serrated running fits across running clearances • Forged shaft; optional stepped
• Renewable casing rings and sleeves • Sleeve radial and tilting pad shaft for high speed or high-
• Flanged balance drum design thrust bearings temperature service
• Chrome plated shafting under • Baseplate designs and pump • Choice of bearings
journal bearings packages engineered to contract −−Ball radial and ball thrust with oil
• Ground forged steel shafting requirements flinger lubrication system
−−Sleeve radial and tilting pad
See Bulletin PS-30-12 See Bulletin PS-30-12 thrust bearings with pressure
lubrication system

See Bulletin PS-30-11


36
WCC (BB5) HDO and HSO (BB5) WIK and WIKO (BB5)
Diffuser Casing, Volute Casing, Multistage, Diffuser Casing,
Multistage, Process Barrel Process Barrel Multistage, Process Barrel

OverhungBearings
Between – General
– Industry
Double Case
Standards Standards Standards
• ISO 13709/API 610 (BB5), latest ed. • ISO 13709/API 610 (BB5), latest ed. • ISO 13709/API 610 (BB5), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 1000 m3/h (4400 gpm) • Flows to 4000 m3/h (17 600 gpm) • Flows to 4000 m3/h (17 610 gpm)
• Heads to 2800 m (9200 ft) • Heads to 5365 m (16 000 ft) • Heads to 7000 m (23 000 ft)
• Discharge pressures to 275 bar • Discharge pressures to 450 bar • Discharge pressures to 650 bar
(3987 psi) (6525 psi) (9425 psi)
• Temperatures to 425°C (800°F) • Temperatures to 425°C (800°F) • Temperatures to 450°C (840°F)
• Speeds to 3580 rpm; 6000 rpm • Speeds to 9000 rpm • Speeds to 13 000 rpm
with high-speed option
Features Features
Features • Dual volute, axially split inner casing • Radially split inner casings
• Internal casing with segmented with opposed grouped impellers • Multi-vane diffuser and channel
stage elements • Heavy-duty barrel with forged steel ring design
• Diffuser-guide vane construction discharge cover • Tandem or imposed impellers
• Multi-vane diffuser-channel • Symmetrical upper and lower • Inner casing with a bolted head
ring collectors half inner volutes at one end
• Precision cast chrome steel in-line • Individually mounted and secured – Optional cartridge element design
impellers impellers – Optional shear ring design
• Single suction or double suction • Dynamic balancing and TIR • Heavy-duty forged steel barrel casing
first stage impeller verifications on assembled rotor and discharge head
• Heavy-duty barrel with • One full pressure sealing • Precision cast and milled diffusers
discharge cover to atmosphere and one full • Precision cast impellers
• Removable cartridge type pressure sealing to suction • Shrink fit and double-keyed impellers
inner case sub-assembly • Sleeve radial and tilting pad • Straight style balance drum
• Straight or flanged balance drum thrust bearings • Tilt pad thrust and sleeve
with serrated running surfaces • Baseplate designs and pump radial bearings
• Tilt pad thrust and heavy-duty packages engineered to contract • Large diameter shaft stepped at each
journal bearings requirements impeller and balance drum
• Force feed lubricated bearings • NEMA taper shaft extension
• Precision-ground forged Other Configurations
steel shafting • Coke crusher (for most sizes) Available Configurations
• WIK: tandem impellers
See Bulletin PS-30-7 See Bulletin PS-30-8 • WIKO: opposed impellers
• Coke crusher (for most sizes)

See Bulletin PS-30-9


37
Vertical Pumps
Wet Pit
WUJ 40
VTP 40
QL 40
QLQ 40

Vertical Pumps
VCT 41
AFV 41
CVP 41
Double Case
QLC 42
QLQC 42
VPC 42
WUC 42
APKD 43
Submersible
Pleuger SUBM 44
Byron Jackson SUBM 44
MSX 44
Slurry and Solids Handling
MVX 45
MFV 45
MNV 45
FRBHJC 46
MJ 46
MJC 46
RJ 46
RJC 46
Terra-Titan 47
MSX 47
Drain-Titan 47
Sump
CPXV Chemical Sump 48
ESP3 Chemical Sump 48
PolyChem VGRP 48
Drain-Titan 49
VSMP 49
ECPJ 49

39
WUJ (VS1) VTP QL and QLQ
Vertical Lineshaft, Vertical Turbine Vertical, Double Suction,
Multistage Twin Volute
Vertical – Wet Pit

Standards Standards Standards


• ISO 13709/API 610 (VS1), latest ed. • Flowserve • Flowserve
• ASME Sections VIII and IX • ASME Sections VIII and IX
• Directive 94/9/EC (ATEX 100) Operating Parameters
• Flows to 13 600 m3/h (60 000 gpm) Operating Parameters
Operating Parameters • Heads to 700 m (2300 ft) • Flows to 25 000 m3/h (110 000 gpm)
• Flows to 3000 m3/h (13 200 gpm) • Pressures to 100 bar (1450 psi) • Heads to 500 m (1640 ft)
• Heads to 2000 m (6560 ft) • Temperatures from -45°C (-50°F) • Pressures to 70 bar (1015 psi)
• Pressures to 200 bar (2900 psi) to 300°C (570°F) • Temperatures to 200°C (400°F)
• Temperatures from -200°C (-328°F) • Sizes from 150 mm (6 in) • Column sizes to 1500 mm (48 in)
to 350°C (660°F) to 1375 mm (55 in)
• Settings to 365 m (1200 ft) Features
Features • Heavy-wall, twin-volute casing
• Radial or mixed flow hydraulics Features • Double suction (first stage) impeller
• Multivane diffuser design • Above- or below-grade discharge • Open lineshaft standard; enclosed
• Optional axial thrust tilting pad • Enclosed or semi-open impellers lineshaft optional
bearing configuration • Open or enclosed lineshaft • Heavy-duty discharge head
• Stiff shaft design construction • Sealed for life bottom bearing
• ISO 21049/API 682 seal chamber • Product or enclosed oil lubrication • Options
accommodates multiple seal types • Flanged or threaded column pipe – ISO 13709/API 610 (VS2), latest ed.,
• Flanged spacer type coupling • High-pressure stuffing box and Directive 94/9/EC (ATEX 100)
• Screen-type, non-sparking • Rigid, adjustable coupling compliant configurations
coupling guard • Drive options – Vertical solid shaft or hollow
• Casing and impeller wear rings – Hollow shaft or solid shaft motor shaft motors with thrust bearing
• Centerline aligned and flanged – Dry or submersible electric motors – Oiler and solenoid switch for
columns – Variable speed drives pump bearing lubrication
• Reinforced motor stand – Engine with right angle gear – Water, grease or oil lubricant
• Optional inducer – Steam turbine – Lubrication lines for bottom bearing
• Options – Antifriction (self-lubricated) or tilting
Related Configurations – Thrust balanced impeller pad axial thrust bearing assembly
• WUC (VS6) double case, – O-ring bowl – Rigid, adjustable spacer coupling
multistage – Adjustable flanged coupling
Available Configurations
See Bulletin PS-40-8 Related Configurations • QL single stage
• VTP molten salt design • QLQ multistage
• VPC vertical turbine, double case • QLC double case, single stage
• QLQC double case, multistage
See Bulletin PS-40-7
40 See Bulletin PS-40-4
VCT AFV CVP
Vertical, Mixed Flow Vertical, Axial Flow Vertical, Concrete Volute

Vertical – Wet Pit


Standards Standards Standards
• Hydraulic Institute • Flowserve • Flowserve
• AWWA • Hydraulic Institute
Operating Parameters
Operating Parameters • Flows to 181 700 m3/h Operating Parameters
• Flows to 181 700 m3/h (800 000 gpm) • Flows to 115 000 m3/h (500 000 gpm)
(800 000 gpm) • Heads to 11 m (35 ft) • Heads to 45 m (147 ft)
• Heads to 110 m (350 ft) • Speeds to 1770 rpm
• Sizes from 1200 mm (48 in) to • Sizes from 200 mm (8 in) Features
3380 mm (133 in) to 3.1 m (123 in) • Vertical dry-pit design
• Settings to 8 m (25 ft) • Removable metallic pump pullout
Features unit within a concrete volute
• Five-mitered elbow discharge head Features • Suction bell connected to preformed
with above- or below-grade discharge • Three- or four-vane axial flow design high efficiency, vortex-free concrete
• Pullout or non-pullout construction • Cast or fabricated bowl assembly suction box
• Flanged outer column with integral • Flanged outer column pipe with • Open mixed flow and closed mixed
bearing bracket integral bearing bracket flow impeller options
• Enclosed or semi-open impellers • Oil, fresh water or self lubricating • Dry shaft design
• Oil, fresh water or self-lubricating lineshaft construction • No submerged bearings
column construction • Fabricated discharge with mitered • Bearings and sealing systems
• Seal chamber accepts packing or elbow easily accessible
mechanical seal • Above- or below-ground discharge • Prefabricated concrete segments
• Three-piece rigid, adjustable • Multiple drive options • Highly corrosion and erosion resistant
motor coupling −−Solid or hollow shaft motor • Liquidyne® or mechanical shaft seal
• Shaft sleeves under the bearings and −−Steam turbine • Inflatable static seal
seal chamber −−Diesel engine • Engineered to customer specifications
• Options • Options
– Discharge head with integral axial −−Casing liners Available Configurations
thrust bearing assembly −−Integral axial thrust bearing • BSV open mixed flow impeller design
– Cast or fabricated bowl assembly assembly • BCV closed mixed flow impeller design
– Integrated suction bell bearing
bracket See Bulletin PS-40-3 See Bulletin PS-40-1
– Multiple stages ® Liquidyne is a registered trademark of IHC
– Thrust collar
– Sand cap
• Engineered to customer specifications

See Bulletin PS-40-6


41
QLC and QLQC VPC WUC (VS6)
Vertical Double Case, Vertical Turbine, Vertical, Double Case,
Double Suction, Double Case Multistage
Twin Volute
Vertical – Double Case

Standards Standards Standards


• Flowserve • ASME Sections VIII and IX • ISO 13709/API 610 (VS6), latest ed.
• ASME Sections VIII and IX • Hydraulic Institute • ASME Sections VIII and IX
• AWWA • German Pressure Vessel
Operating Parameters Association (AD)
• Flows to 25 000 m3/h (110 000 gpm) Operating Parameters • British Standard BS 5500
• Heads to 500 m (1640 ft) • Flows to 13 600 m3/h (60 000 gpm) • Compliance with Pressure
• Pressures to 70 bar (1015 psi) • Heads to 1070 m (3500 ft) Equipment Directive 97/23/EC
• Temperatures from -45°C (-50°F) • Pressures to 100 bar (1450 psi)
to 200°C (400°F) • Temperatures from -45°C (-50°F) Operating Parameters
to 230°C (450°F) • Flows to 3000 m3/h (13 200 gpm)
Features • Heads to 2000 m (6560 ft)
• Double case construction Features • Pressures to 200 bar (2900 psi)
• Heavy-wall twin-volute casing • Diffuser design • Temperatures from -200°C (-328°F)
• Double suction (first stage) impeller • Above- or below-grade discharge to 350°C (660°F)
• Open lineshaft construction • ASME Class 150 or 300 slip-on flanges
• Seal chamber accommodates • Single or multistage designs Features
cartridge style single, dual • Enclosed or semi-open impellers • Radial or mixed flow hydraulics
unpressurized and dual pressurized • Large eye first stage impeller • Low suction-velocity can design
mechanical seals • Product or oil bearing lubrication • Optional axial thrust tilting pad
• Heavy-duty discharge head • Flanged column pipe bearing configuration
• Options • High-pressure stuffing box • Stiff shaft design
−−ISO 13709/API 610 (VS7), latest • Rigid, adjustable flanged coupling • ISO 21049/API 682 seal chamber
ed., compliant designs • Drive options accommodates multiple seal types
−−Directive 94/9/EC (ATEX 100) – Hollow shaft or solid shaft motor • Flanged spacer type coupling
available – Variable speed drive • Screen-type, non-sparking
−−Vertical solid shaft or hollow shaft – Engine with right angle gear coupling guard
motors with thrust bearing – Steam turbine • Inside drain line
−−Antifriction (self-lubricated) or tilting • Other options • Casing and impeller wear rings
pad axial thrust bearing assembly – Integral axial thrust bearing • Reinforced motor stand
– Rigid, adjustable spacer coupling assembly • Optional inducer
– O-ring construction
Available Configurations – Keyed impellers Related Configurations
• QLC double case, single stage – Bowl and impeller wear rings • WUJ (VS1) vertical line shaft,
• QLQC double case, multistage multistage
• QL single stage Related Configurations • WUC-LNG cryogenic (VS6) double
• QLQ multistage • VTP vertical turbine case, multistage
42 See Bulletin PS-40-4 See Bulletin PS-40-7 See Bulletin PS-40-9
APKD
Vertical, Double Case,
Double Suction

Vertical – Double Case


Standards
• Flowserve

Operating Parameters
• Flows to 4600 m3/h (20 200 gpm)
• Heads to 500 m (1640 ft)
• Pressures to 50 bar (725 psi)
• Temperatures from -45°C (-50°F)
to 95°C (200°F)
• Speeds to 1800 rpm

Features
• Double suction first stage impeller
• Double case construction
• Impellers keyed with lock collars
• Twin-volute casing
• Heavy-duty discharge head
• Open lineshaft construction
• Flanged column assembly with
bearing retainers
• Large shaft with keyed lineshaft
couplings
• Mechanically sealed
• Rigid, adjustable flanged coupling
• Solid shaft motor with NEMA or IEC
thrust bearing
• Optional suction can drain

Related Configurations
• APKC single suction design

43
Pleuger SUBM Byron Jackson SUBM MSX
Deep-Well Submersible Deep-Well Submersible Solids Handling,
(Water-Filled Design) (Oil-Filled Design) Submersible
Vertical – Submersible

Standards Standards Standards


• Flowserve • Flowserve • Flowserve
• CSA, WIMES 3.03, EMV, KTV, CE, • NSF Standard 61 Certification
VDE and other certifications • Certification program accredited by Operating Parameters
RvA, Dutch Council for Accreditation • Flows to 4545 m3/h (20 000 gpm)
Operating Parameters • Heads to 90 m (300 ft)
• Flows to 4500 m3/h (19 800 gpm) Operating Parameters • Temperatures to 40°C (104°F)
• Heads to 800 m (2625 ft) • Flows to 4500 m3/h (19 800 gpm) • Discharge sizes from 80 mm (3 in)
• Motor sizes to 5000 kW (6700 hp) • Heads to 800 m (2625 ft) to 500 mm (20 in)
• Speeds from 200 to 3600 rpm • Motor sizes to 1500 kW (2000 hp) • Motor to 224 kW (300 hp)
• Speeds from 1000 to 3600 rpm • Solids handling to 80 mm (3 in)
Features diameter spherical
• Wet type motors with watertight Features
insulated windings • Oil-filled motors with self-contained Features
• Dynamically balanced impellers force feed, filtered, cooled oil • High-efficiency hydraulics
• Prefilled motors with food grade circulation system • EPACT rated motor
additives • Vacuum pressure impregnated (VPI) • Spike-resistant windings
• Heavy-duty, adjustable, self-aligning epoxy, class F insulation system • Class H rated insulation system
thrust bearings • Double-acting thrust bearing system • Dynamically balanced shaft
• Friction welded shafts • Dynamically balanced, heavy-duty, and rotor
• Non-toxic Class Y winding insulation high-efficiency impellers • Mounting options
for potable water services • Variable frequency drive and high- – Wet pit
• Variable frequency drive and high- temperature options – Dry pit
temperature options • Choice of materials – Transportable
• Choice of materials – Cast iron
– Cast iron – Bronze Available Configurations
– Bronze – Austenitic stainless steels • MSX Series 1: Sizes from
– Austenitic stainless steels −−Duplex stainless steels 75 mm (3 in) to 150 mm (6 in)
−−Duplex stainless steels – Reinforced composite • MSX Series 2/3: Sizes to
– Reinforced composite • Choice of seals 500 mm (20 in)
– Mercury seal
Related Configurations – Double mechanical seal See Bulletin PS-50-2
• Byron Jackson SUBM deep-well – Single, pressurized mechanical seal
submersible (oil-filled design)
Related Configurations
See Bulletin PS-50-3 • Pleuger SUBM deep-well
submersible (water-filled design)
44 See Bulletin PS-50-3
MVX MFV MNV
Solids Handling, Wet Pit Solids Handling Large Capacity,
Solids Handling

Vertical – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 17 000 m3/h (75 000 gpm) • Flows to 2275 m3/h (10 000 gpm) • Flows to 45 500 m3/h (200 000 gpm)
• Heads to 40 m (130 ft) • Heads to 90 m (300 ft) • Heads to 90 m (300 ft)
• Sizes 250 mm (10 in) to 1200 mm • Sizes to 400 mm (16 in) • Sizes to 1800 mm (72 in)
(48 in)
• Drivers to 950 kW (1250 hp) Features Features
• Solids up to 150 mm (6 in) • Variety of nozzle position options • Variety of nozzle position options
• Direct or independent motor mounting • Direct or independent motor mounting
Features • Minimal shaft deflection • Minimal shaft deflection
• Heavy-duty fabricated discharge • Oversized shaft and reduced overhang • Oversized shaft and reduced overhang
head designed with fabricated flange • Hardened chrome steel wear rings • Hardened chrome steel wear rings
and splitter vane • Seal chamber accommodates packing • Seal chamber accommodates packing
• Symmetrical bowl with multi- or mechanical seals or mechanical seals
volute design • Adjustable impeller clearance • Adjustable wear ring clearance
• Hydraulically balanced design • Shaft sleeve options • Shaft sleeve options
• Enclosed non-clog impeller – 316 stainless steel – 316 stainless steel
• Enclosed lineshaft – Hardened chrome steel – Hardened chrome steel
• Splitter vane in the column and • Bearing housing features • Bearing housing features
discharge head – Ball or tapered roller bearings – Tapered roller bearings
• Mechanical seal or soft packing shaft – Integral jacking bolts for wear – Integral jacking bolts for wear
sealing options ring adjustment ring adjustment
• Hollow or solid shaft motor style – Accessible lubrication points – Accessible lubrication points
• 416 stainless steel lineshafts
• Separate steel soleplate Available Configurations Available Configurations
• Bronze lineshaft bearings • MF horizontal, end suction • MN horizontal, end suction
• Suction bell • MFV vertical with motor on • MNF vertical, bottom suction,
• Standard suction bell wear rings separate floor (shown) direct connected motor
• Optional impeller wear rings • MFC vertical with direct connected • MNZ vertical, bottom suction,
motor motor on separate floor
See Bulletin PS-40-5 • MNC vertical with base elbow,
See Bulletin PS-10-3 direct connected motor
• MNV vertical with base elbow,
motor on separate floor (shown)

See Bulletin PS-10-4


45
FRBHJC MJ and MJC RJ and RJC
Cantilever Sump Hard Metal, Slurry Sump Rubber Lined, Slurry Sump
Vertical – Slurry and Solids Handling

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 2700 m3/h (12 000 gpm) • Flows to 225 m3/h (1000 gpm) • Flows to 225 m3/h (1000 gpm)
• Heads to 100 m (330 ft) • Heads to 30 m (100 ft) • Heads to 30 m (100 ft)
• Temperatures to 150°C (300°F) • Pressures to 10 bar (150 psi) • Pressures to 10 bar (150 psi)
• Speeds to 1780 rpm • Temperatures to 110°C (225°F) • Temperatures to 110°C (225°F),
• Solids from 2% to 70% by weight depending on material
Features • Speeds to 1780 rpm • Solids from 2% to 70% by weight
• True stiff shaft cantilever design, • Speeds to 1780 rpm
without bottom bearing or Features
flushing water • Abrasion- and corrosion-resistant Features
• Steep head capacity high chrome iron concentric casing • Radially split casing with anti-
• Semi-open, full vane impeller with • Integrally cast straightening vanes prerotation vanes in suction nozzle
back pump-out vanes in the suction nozzle • Casing liners pressure molded
• Direct coupled or V-belt driven • Closed impeller with pump-out vanes on steel backing plates; multiple
• Extra heavy-duty alloy steel shaft on front and rear shrouds materials available
• MJ has fluted cutlass rubber • Pressure molded rubber closed
Related Configurations bearings impeller with pump-out vanes on
• FRBH heavy-duty paper stock • MJC has restriction bushing front and rear shrouds
and process • Directly coupled or V-belt driven • RJ has fluted cutlass rubber
• FRBHJ vertical lineshaft sump • Options bearings
– Hard metal expeller • RJC has restriction bushing
See Bulletin PS-10-16 – Open and recessed impellers • Directly coupled or V-belt driven
– Choice of materials • Options
– Hard metal expeller
Available Configurations – Choice of liner materials
• MJ submerged bearing and
lineshaft design Available Configurations
• MJC cantilever design • RJ submerged bearing and
• M horizontal, hard metal lineshaft design
abrasive slurry • RJC cantilever design
• R horizontally split, rubber
See Bulletin PS-10-19 lined slurry

See Bulletin PS-10-18


46
Terra-Titan MSX Drain-Titan
Cantilever Sump Solids Handling, Urethane Lined,
Submersible Double Suction Sump

Vertical – Slurry and Solids Handling


Standards Standards Standards
• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 250 m3/h (1100 gpm) • Flows to 4545 m3/h (20 000 gpm) • Flows to 160 m3/h (700 gpm)
• Heads to 45 m (150 ft) • Heads to 90 m (300 ft) • Heads to 40 m (130 ft)
• Pressures to 5 bar (70 psi) • Temperatures to 40°C (104°F) • Pressures to 4 bar (55 psi)
• Temperatures to 100°C (212°F) • Discharge sizes from 80 mm (3 in) • Sizes from 40 mm (1.5 in)
• Sizes from 40 mm (1.5 in) to 500 mm (20 in) to 100 mm (4 in)
to 125 mm (5.0 in) • Motor to 224 kW (300 hp) • Solids to 15 mm (0.5 in)
• Sump depths from 700 mm • Solids handling to 80 mm (3 in)
(28 in) to 1800 mm (72 in) diameter spherical Features
• Double suction, urethane coated
Features Features wet-end
• One-piece suspended, oversized • High-efficiency hydraulics • Robust, integral unit construction
cantilever shaft construction • EPACT rated motor • Large diameter, stiff cantilever
• Interchangeable urethane or hard • Spike-resistant windings drive shaft
metal wetted parts • Class H rated insulation system • No submerged bearings or seals
• Concentric casing design • Dynamically balanced shaft • Double-sided impeller with
• Double suction, hydraulically and rotor pre-set clearance
balanced open impeller • Mounting options • Keyed and bored shaft coupling
• External impeller adjustment – Wet pit • Standard single lip oil seal
• Renewable Terraprene urethane – Dry pit • Urethane lined, slotted outlet
shaft sleeve – Transportable pipe flange
• Greased for life, heavy-duty, • Grease lubricated, single row,
self-aligning roller bearings Available Configurations deep groove ball bearings
• Upper and lower strainers • MSX Series 1: Sizes from • No priming required
• Run-dry capability 75 mm (3 in) to 150 mm (6 in) • Run-dry capability
• ANSI and ISO configurations • MSX Series 2/3: Sizes to
• Portable 500 mm (20 in) See Bulletin PS-10-7
• Lifting lugs
• Rigid motor mount pivot bar See Bulletin PS-50-2
• Available bottom suction tailpipe
• Multiple drive options

See Bulletin PS-10-7

47
CPXV ESP3 PolyChem VGRP
Chemical Sump Chemical Sump Engineered Polymer
Composite Sump
Vertical – Sump

Standards Standards Standards


• ISO 13709/API 610, 8th & 10th ed. • Flowserve • Flowserve
• ISO 5199
Operating Parameters Operating Parameters
Operating Parameters • Flows to 1365 m3/h (6000 gpm) • Flows to 565 m3/h (2500 gpm)
• Flows to 1400 m3/h (6160 gpm) • Heads to 90 m (300 ft) • Heads to 110 m (350 ft)
• Heads to 250 m (820 ft) • Pressures to 12 bar (175 psi) • Pressures to 17 bar (250 psi)
• Pressures to 25 bar (365 psi) • Temperatures to 180°C (350°F) • Temperatures from -30°C (-20°F)
• Temperatures from -40°C (-40°F) to 90°C (200°F)
to 350°C (660°F) Features
• Optimized lineshaft bearing design Features
Features to ISO 13709/API 610 spacing • Glass reinforced vinyl ester
• Heavy-duty casing with multi-ribbed requirements • Unitized casing with integrally
discharge flange • Double row external thrust bearings molded, fully gusseted suction
• High-efficiency, semi-open impeller • Single and duplex configurations and discharge flanges
• Column lengths to 10 m (32 ft) • Flanged discharge • Externally adjustable, semi-
• Heavy-duty thrust bearings with axial • Large basket strainer open impeller
adjustment above soleplate level • Industry standard TCV motors • Shaft and bearing system operates
• Accepts multiple seal arrangements • Lubrication options well below the first critical speed
• Elastomeric split element coupling – Product lube for clear liquids • Self-lubricated or external
• Options – Dual particle separator for flush bearings
−−Recessed impeller light solids • Single-piece, lightweight, filament-
−−Suction strainer – Grease lubrication wound, reinforced fiberglass
−−Spacer coupling • Mounting plate sealing options composite column
−−Rectangular or circular soleplate – Vapor tight • Single and duplex configurations
−−Oil lubrication to thrust bearing – Vapor proof • Full basket strainer
−−Zone Ø hazardous area beneath – Pressurized design • NEMA in-line motor
soleplate configuration • Options • Fiberglass mounting plate
• CE marked and compliant with – Upper stuffing box • Tapered polygon impeller drive
applicable European directives such – Sealing ring • Pullout bearing retainers
as ATEX; available with GOST – Suction tailpipes • Level controls
certification – Level controls • Choice of shaft metallurgy

Other Configurations Related Configurations Related Configurations


• CPXVR recessed impeller, • ESP3 Lo-Flo • PolyChem GRP engineered
chemical sump • ESP3 recessed impeller polymer composite
• Fully jacketed, molten salt design • ESP3 high chrome iron
See Bulletin PS-10-17
48 See Bulletin PS-10-30 See Bulletin PS-10-24
Drain-Titan VSMP ECPJ (VS4)
Urethane Lined, Vertical Standard Motor Sump
Double Suction Sump

Vertical – Sump
Standards Standards Standards
• Flowserve • Flowserve • ISO 13709/API 610 (VS4), latest ed.

Operating Parameters Operating Parameters Operating Parameters


• Flows to 160 m3/h (700 gpm) • Flows to 135 m3/h (600 gpm) • Flows to 1000 m3/h (4400 gpm)
• Heads to 40 m (130 ft) • Heads to 70 m (220 ft) • Heads to 150 m (500 ft)
• Pressures to 4 bar (55 psi) • Pressures to 12 bar (175 psi) • Pressures to 20 bar (285 psi)
• Sizes from 40 mm (1.5 in) • Temperatures from -40°C (-40°F) • Temperatures to 350°C (660°F)
to 100 mm (4 in) to 120°C (250°F) • 45 sizes available
• Solids to 15 mm (0.5 in)
Features Features
Features • Glass reinforced polymer, high- • Lineshaft configuration
• Double suction, urethane coated efficiency, semi-open or closed • Four impeller designs
wet-end impellers standard – Closed multivane impeller with
• Robust, integral unit construction • Industry standard NEMA motors front wear rings and back vanes
• Large diameter, stiff cantilever • Stainless steel, self-aligned – Closed multivane impeller with
drive shaft mechanical seal front and rear wear rings
• No submerged bearings or seals • Back pullout design – Open multivane impeller with
• Double-sided impeller with • Clamp-type mounting plate back vanes
pre-set clearance • Options – Free flow impeller with back vanes
• Keyed and bored shaft coupling – Cast iron, bronze or 316 stainless • Multiple shaft sealing options
• Standard single lip oil seal steel impellers – V-ring
• Urethane lined, slotted outlet – Stub shaft design – Throttle bushing
pipe flange – Lip seal with grease-filled
• Grease lubricated, single row, Related Configurations stuffing box
deep groove ball bearings • SMP standard motor pump – Soft packing
• No priming required • SMX non-metallic standard • ISO 21049/API 682 seal chamber
• Run-dry capability motor pump accommodates multiple seal types
• Column lengths to 6 m (22 ft);
See Bulletin PS-10-7 See Bulletin PS-10-26 suction pipe available
• Choice of ISO/API materials
• NACE MR0175 materials available
• Internal or external bearing flushing
• Bearing cooling
• Suction strainer

See Bulletin PS-10-10


49
Positive Displacement
Gear
GR Series 52
GA Series 52
Gearex 52

Positive Displacement
Screw
TSP 53
MP1 53
MP1 Systems Packaging 53
Reciprocating
YHT 54
HS 54
VTE 54
VQE 54
V 54
VSE 54

51
GR Series GA Series Gearex
Double Helical, Gear Cast Iron, Double Helical,
Double Helical, Gear Timed Gear
OverhungDisplacement
Positive – General Industry
– Gear

Standards Standards Standards


• Flowserve • Flowserve • Flowserve

Operating Parameters Operating Parameters Operating Parameters


• Flows to 275 m3/h (1200 gpm) • Flows to 27 m3/h (120 gpm) • Flows to 180 m3/h (800 gpm)
• Pressures to 35 bar (500 psi) • Pressures to 17 bar (250 psi) • Pressures to 20 bar (300 psi)
• Temperatures to 350°C (650°F) • Temperatures to 175°C (350°F) • Temperatures from -50°C (-60°F)
• Speeds to 1800 rpm • Speeds to 1800 rpm to 450°C (850°F)
• Viscosities to 1 million ssu • Viscosities to 50 000 ssu • Viscosities to 1 million ssu

Features Features Features


• Double helical, herringbone gears • Double helical, herringbone gears • Double helical, herringbone gears
• Quiet, pulse-free flow • Quiet, pulse-free flow • Quiet, pulse-free flow
• High speed pump capability • High speed pump capability - • External timing gears
• Between bearings design off-the-shelf motors • Between bearings design
• Hydraulically balanced design • Between bearings design • Heavy-duty, double row roller
• Stuffing box accommodates packing • Self-lubricated babbitted carbon bearings
or mechanical seals sleeve bearings standard; bronze • Direct coupled
• High-capacity, double row roller bearing bearings optional • Options
• Self-priming • Hydraulically balanced design – – Water cooled bearings
• Run dry capability no thrust bearings needed – Steam or water jacketed bodies
• Low NPSHr • Convertible stuffing box accommo- – Vertical mounting configuration
• Back pullout design dates packing or mechanical seals – Mechanical seals
• Options • Threaded ports – Lantern rings
– Mechanical seal • Back pullout design – Shaft slingers
– Direct V-belt drive • Available integral safety relief valve – Split bearing brackets
– Extra deep jacketed stuffing box • Multiple mounting configurations – Flange mounting brackets
– Jacketed body – Jackshafts for V-belt drives
– Babbitted carbon sleeve bushing Related Configurations
– INSUROCK® wearplates • GAS foot mounting (standard)
– Integral safety relief valve • GAF flange mounting
• GAC close coupled
Available Configurations
• GSX series stainless steel, double
• GR standard gear width
helical, rotary gear pumps
• GRW wide gears for high flows
• GRH narrow gears for high pressures

See Bulletin PS-60-3


52 ® INSUROCK is a registered trademark of Richardson Company, Inc.
TSP MP1 MP1
Double Suction, Multiphase Twin-Screw Systems Packaging
Twin-Screw

OverhungDisplacement
Positive – General Industry
– Screw
Standards Standards Standards
• API 676, latest ed. • API 676, latest ed. • Flowserve
• ASME
Operating Parameters Operating Parameters
• Flows to 2550 m3/h (11 200 gpm) • Flows to 1990 m3/h (8750 gpm) Features
• Pressures to 100 bar (1450 psi) • Pressures to 50 bar (720 psi) • Standard or custom engineered
• Temperatures to 450°C (850°F) • Temperatures to 450°C (850°F) system packaging available
• Speeds to 1800 rpm • Speeds to 2000 rpm • Driver options
• Viscosities to 200 million ssu • Viscosities to 8000 cp −−Electric motor
• Slurry concentrations to 70% • Multiphase pumping to 100% GVF −−Electric motor with variable speed
by weight (gas void fractions) drive (VSD)
−−Diesel or natural gas engine
Features Features • Complete piping systems
• Positive displacement • Non-contacting design with −−Suction, discharge, bypass and
timed two-screw one-piece pump shafts recycle piping
• Double suction design • Three pumping locks for low −−Block valves, control valves and
• Split bearing bracket for ease pulsation flow check valves
of maintenance • Through-bolt bearing bracket design −−Filters and strainers
• Versatile ISO 21049/API 682 • ISO 21049/API 682 seal chamber −−Pressure, temperature and flow
compliant stuffing box design with split brackets accommodates instrumentation
• Integral or pinned screw elements single and double cartridge seals • Complete, integrated control systems
• Spur-tooth timing gears • Double suction design with low −−PLC based
• Chrome-plated pump bores NPSH capability −−Controls for pump, valves, instru-
• Options • AGMA 11 helical timing gears mentation and alarms, VSD, etc.
– Fully external bearings and • Chrome plated bores and hard −−Motor control center
timing gears coated screws • Single and multiple skid options
– Internal bearings and timing gears • Options for integration of controls, pump
– Temperature control packages −−Multiple hard coatings for bores and piping
– Hopper-top construction and screws • Special enclosures for arctic-
– Vertical barge configuration −−Choice of materials, including NACE like conditions or other harsh
– Choice of materials −−Customized pitch environments
– Multiple hard coatings for bores −−Customized packaging
and screws −−Variable speed drive
−−Natural gas or diesel engine drive
See Bulletin PS-60-1
Other Configurations
• High pressure: 100 bar (1450 psi)

See Bulletin PS-60-2 53


YHT and HS VTE , VQE, V and VSE
Horizontal Reciprocating Vertical Reciprocating
OverhungDisplacement
Positive – General Industry
– Reciprocating

Standards Standards
• API 674, latest ed. • API 674, latest ed.
• ASME section III • ASME section III

Operating Parameters Operating Parameters


• 75 mm (3 in) to 250 mm • 140 mm (5.5 in) to 225 mm
(10 in) stroke (9 in) stroke
• Flows to 775 m3/h (3400 gpm) • Flows to 1140 m3/h (5000 gpm)
• Standard pressures to 555 bar • Standard pressures to 619 bar
(8030 psi); custom pressures to (8975 psi); custom pressures to
2070 bar (30 000 psi) 2070 bar (30 000 psi)
• Temperatures from -40°C (-40°F) • Temperatures from -40°C (-40°F)
to 350°C (650°F) to 350°C (650°F)
• Power to 2560 kW (3430 hp) • Power to 3450 kW (4625 hp)
• Speeds to 530 rpm • Speeds to 360 rpm

Features Features
• Self-aligning plungers • Outboard packed inverted design
• Sectionalized fluid end components • Easily accessible stuffing box
• Fully enclosed power end with • Integrated suction and discharge
generous oil reservoir manifold
• Independent crosshead extension rod • Complete separation of liquid end
• Integrally cast and precision machined from power end
cylindrical crosshead guides • Valve design suitable for conditions
• Triple lip seal at crosshead extensions of service
• Fully reversible crankshaft for V-belt • Spherical feature for plunger alignment
drive or direct coupling • Power-end maintenance
• Stuffing box assemblies individually inspection covers
bolted to fluid cylinder • Forced feed lubrication
• Splash-type or full pressure • Options
lubrication system −−Spring loaded packing
• Threaded primary drain −−Pulsation dampeners
• Options −−Sectionalized fluid ends
– Overhead motor mounting
– Spring loaded stuffing box See Bulletin PS-70-1
– Discharge pulsation dampeners

See Bulletin PS-70-1


54
Overhung – General Industry

55
Specialty Products
Nuclear Pumps and Seals
DFSS 58
DVSS 58
N-Seals 58
WDF 58

Specialty Products
DVSR 59
CN 59
HDR 59
CA 60
CAM 60
CAV 60
EG 61
MEV 61

Extreme Temperature
WUC-LNG Cryogenic 62
VKW Cryogenic 62
TKW Cryogenic 62
Byron Jackson 62
SUBM Geothermal
Others
Hydraulic Decoking Systems 63
Pleuger WFSD 63
Azimuthing Thruster
DWEER™ 64
ERT 64
CVP 64
Barge Pump 65
Molten Salt VTP 65

57
DFSS and DVSS N-Seals Nuclear WDF Nuclear
Nuclear Radially Split, Mechanical Seals Vertical, Single Stage
Single Stage
Overhung Products
Specialty – General
– Nuclear
IndustryPumps and Seals

Standards Standards Standards


• ASME Section III, Class 1 • ASME Section III, Class 1 • ASME Section III, Class 2 and 3

Operating Parameters Operating Parameters Operating Parameters


• Flows to 24 500 m3/h (108 000 gpm) • Pressures to 150 bar (2175 psi) • Flows to 900 m3/h (4000 gpm)
• Heads to 250 m (820 ft) • Temperatures to 80°C (180°F) • Heads to 245 m (800 ft)
• Pressures to 170 bar (2500 psi) • Speeds to 1800 rpm
• Temperatures to 300°C (580°F) Services
• Speeds to 1800 rpm Services • Containment spray
• Power rating to 9400 kW (12 600 hp) • Primary coolant • Low pressure safety injection
• Reactor recirculation • Residual heat removal
Services • Primary heat transport
• Primary coolant Features
• Reactor recirculation Features • Vertical, single stage design
• Primary heat transport • Controlled leakage seal • Bottom suction, horizontal discharge
• Two to four stage configurations • Forged diffuser casing design
Features • Provisions for monitoring pressure, • Optimized hydraulic performance
• Fourth generation design temperature and flow at each stage • Unique spacer coupling design
• One-piece cast pump casing • Internal screens for trapping particles • Mechanical seal replacement without
• Double volute design case for BWR • Each stage capable of handling full motor or casing cover removal
and PHWR system pressure - redundancy • Upgraded rotor design
• Diffuser with torus-type design • Optional hydrodynamic features and – Radial bearing located between
casing for PWR dirt grooves coupling and seal
• Upgraded rotating element • Variety of seal face materials available – Reduced shaft deflection
– One-piece welded shaft-impeller- • All stages use the same components – Improved pump and mechanical
journal assembly and are interchangeable seal life and reliability
– Fully machined and balanced • Seal faces are supported by gaskets • Cartridge mechanical seal
as single rotating unit to minimize pressure points • Reduced assembly time
• Hydrostatic-pressurized radial bearing and deflection
– Operates submerged in radioactive See Bulletin FPD-2
system water at loop temperature See Bulletin PSS-80-2.2
of approximately 300°C (580°F)

See Bulletin FPD-2

58
DVSR Nuclear CN Nuclear HDR Nuclear
Radially Split, Volute Radially Split, Diffuser Radially Split, Volute
Casing, Single Stage Casing, Single Stage Casing, Single Stage

Overhung Products
Specialty – General
– Nuclear
IndustryPumps and Seals
Standards Standards Standards
• ASME Section VIII • ASME Section VIII • ASME Section VIII

Operating Parameters Operating Parameters Operating Parameters


• Flows to 4535 m3/h (19 945 gpm) • Flows to 5065 m3/h (22 300 gpm) • Flows to 5065 m3/h (22 300 gpm)
• Heads to 800 m (2625 ft) • Heads to 800 m (2625 ft) • Heads to 800 m (2625 ft)
• Pressures to 100 bar (1470 psi) • Pressures to 100 bar (1470 psi) • Pressures to 100 bar (1470 psi)
• Temperatures to 210°C (410°F) • Temperatures to 210°C (410°F) • Temperatures to 210°C (410°F)
• Power to 8000 kW (10 700 hp) • Power to 11 200 kW (15 000 hp) • Power to 11 200 kW (15 000 hp)
• Speeds to 6000 rpm • Speeds to 6000 rpm • Speeds to 6000 rpm

Services Services Services


• Reactor and steam generator feedwater • Reactor and steam generator • Reactor and steam generator
feedwater feedwater
Features
• Cast volute casing configuration Features Features
• Double cover design • Diffuser casing configuration • Volute casing configuration
• High speed pump design • Forged barrel • Forged barrel
• Double suction impeller • High-speed pump design • High-speed pump design
• Centerline mounted • Double suction impeller • Double suction impeller
• Pressure breakdown bushing or • Special impeller designs for low • Special impeller designs for low
mechanical seal NPSHa conditions NPSHa conditions
• Sleeve radial and tilting pad thrust • Centerline mounted • Centerline mounted
bearings standard • Pressure breakdown bushing or • Pressure breakdown bushing or
mechanical seal mechanical seal
See Bulletin FPD-2 • Sleeve radial and tilting pad thrust • Sleeve radial and tilting pad thrust
bearings standard bearings standard

See Bulletin PS-80-2 See Bulletin PS-80-2

59
CA Nuclear CAM Nuclear CAV Nuclear
Diffuser Casing, Diffuser Casing, Vertical, Double Case,
Multistage, Utility Barrel Multistage, Utility Barrel Multistage
Overhung Products
Specialty – General
– Nuclear
IndustryPumps and Seals

Standards Standards Standards


• ASME Section III, Class 2 and 3 • ASME Section III, Class 2 and 3 • ASME Section III, Class 2 and 3

Operating Parameters Operating Parameters Operating Parameters


• Flows to 5250 m3/h (23 000 gpm) • Flows to 45 m3/h (200 gpm) • Flows to 60 m3/h (265 gpm)
• Discharge pressures to 450 bar • Heads to 1920 m (6300 ft) • Heads to 2000 m (6560 ft)
(6500 psi) • Pressures to 235 bar (3410 psi) • Pressures to 235 bar (3410 psi)
• Temperatures to 250°C (480°F) • Temperatures to 120°C (250°F) • Temperatures to 100°C (212°F)
• Speeds to 6000 rpm • Speeds to 3600 rpm
Services
Services • CVCS charge Services
• Safety injection • Control rod drive • CVCS charge

Features Features Features


• Internal casing with segmented • Multistage, double case design • Multistage, double case design
stage elements • Unique, compact design patented • Barrel rated at full discharge pressure
• Diffuser-guide vane construction modular impellers • Suction and discharge connections at
• Precision cast in-line impellers – Low-flow stability and reliability bottom of barrel
• Heavy-duty forged barrel with forged over a wide range of flows • Diffuser design with back-to-back
steel discharge cover – No surging or pulsations impeller mounting to minimize thrust
• Balance drum and sleeve, made • Ball-ball construction • Cartridge mechanical seal
from hardened stainless forgings • Dry disk spacer coupling • Thrust bearings provided in either
• Ball thrust and ball radial bearings • Flanged axial thrust-balancing device pump or motor as required
• Fan-cooled bearing housings • Modularized assembly and • Spacer coupling
• Renewable casing rings and sleeves disassembly may be conducted
• Ground forged steel shafting without the use of a torch See Bulletin FPD-2
• Cartridge seals • Forged barrel with no
attachment welds
See Bulletin FPD-2 • Cartridge mechanical seals with
no attachment welds
• No auxiliary cooling required

See Bulletin FPD-2

60
EG Nuclear MEV Nuclear
Radially Split, Double Vertical, Single Stage
Suction

Overhung Products
Specialty – General
– Nuclear
IndustryPumps and Seals
Standards Standards
• ASME Section III, Class 3 • ASME Section III, Class 3

Operating Parameters Operating Parameters


• Flows to 4000 m3/h (17 610 gpm) • Flows to 5400 m3/h (23 760 gpm)
• Heads to 60 m (200 ft) • Heads to 50 m (160 ft)
• Pressures to 14 bar (200 psi) • Pressures to 14 bar (200 psi)
• Temperatures to 80°C (180°F) • Temperatures to 80°C (180°F)
• Power to 950 kW (1275 hp) • Speeds to 3600 rpm
• Speeds to 3600 rpm
Services
Services • Essential and non-essential
• Component cooling water service water

Features Features
• Cast volute casing • Cast casing and cover
• Double cover design • Bottom suction, horizontal discharge
• Double suction impeller configuration
• Centerline mounting • Single stage, enclosed impeller
• Side suction and side discharge • Fabricated motor stand
located above the mounting feet • Cartridge mechanical seal
• Cartridge mechanical seal • Radial roller and double ball
• 360° bearing housings thrust bearings
• Ball radial and ball thrust bearings • Grease lubricated bearings

See Bulletin FPD-2 See Bulletin FPD-2

61
WUC-LNG Cryogenic (VS6) VKW and TKW Cryogenic Byron Jackson SUBM
Vertical, Double Case, Liquid Expander (VS6) Geothermal Deep-Well
Multistage Double Case, Multistage, Submersible
Electric Generator
Overhung Products
Specialty – General
– Extreme
IndustryTemperature Pumps

Standards Standards Standards


• API 610 (VS6), latest edition • API 610 (VS6), latest edition • IEC/VDE and other certifications
• ASME Sections VIII and IX • ASME Sections VIII and IX
• German Pressure Vessel Operating Parameters
Association (AD) Operating Parameters • Flows to 720 m3/h (3170 gpm)
• British Standard BS 5500 • Expander flows to 2500 m3/h • Heads to 800 m (2625 ft)
• Compliance with Pressure Equipment (11 000 gpm) • Temperatures to 160°C (320°F)
Directive 97/23/EC • Inlet pressures to 70 bar (1000 psi) • Motor sizes to 1500 kW (2000 hp)
• Temperatures to -180°C (-290°F) • Speeds from 2900 to 3500 rpm
Operating Parameters • Power to 3 MW (4000 hp) • Inner well diameters from 340 mm
• Flows to 3000 m3/h (13 000 gpm) • Runaway speed to 5400 rpm (13-3/8 in) to 508 mm (20 in)
• Heads to 1200 m (3900 ft)
• Pressures to 200 bar (3000 psi) Features Features
• Temperatures from -200°C (-325°F) • Variable or fixed geometry • Pump and motor design for
to -45°C (-50°F) • Externally driven remote and local geothermal application
controlled variable wickets • Oil filled motor with self-contained
Features • Optimal isentropic efficiency force feed, filtered, cooled oil
• Coffer dam system • Overall improvement of compressor circulation system
• Radial or mixed flow hydraulics power efficiency • Vacuum pressure impregnated (VPI)
• Low suction velocity can design • Air-cooled generator epoxy, Class F, insulation system
• Optional axial thrust tilting pad • Temperature reduction through • Winding insulation system Class C
bearing configuration liquid expansion 220°C (428°F)
• Stiff shaft design • Additional electric generation • Double cable plug construction
• API 682 compliant mechanical • Low vibration • Double-acting thrust bearing system
seal chamber • Low noise level • Dynamically balanced heavy-duty,
• Flanged spacer type coupling • State-of-the-art gas seal high-efficiency impellers
• Screen-type, non-sparking • Optimum specific speed selection • Optional variable frequency
coupling guard • Choice of materials
• Inside drain line Available Configurations • Double mechanical seal
• Casing and impeller wear rings • TWK variable geometry, double • Motor design with breather diaphragm
• Reinforced motor stand casing, multistage, electric generator for pressure compensation
• Optional inducer • VKW fixed geometry, double case, • Non-return design for high pressure
multistage, electric generator • Down hole monitoring system
Related Configurations
• WUC (VS6) double case, See Bulletin PSS-90-7.1 Other Configurations
multistage • Byron Jackson SUBM deep-well
submersible (oil-filled design)
See Bulletin PSS-40-9.1
62
Hydraulic Decoking Systems Pleuger WFSD
Azimuthing Thruster

Overhung Products
Specialty – General
– Others
Industry
Flowserve Automated Hydraulic • Provides greater system automation Standards
Decoking Systems and improved efficiency while • Flowserve
• Increase delayed coking unit (DCU) improving operator safety, reducing
capacity and improve operator safety cycle time and easing maintenance Applications
• Installed in more than 95% of • Mode shifting helps to free impeded • Semi-submersible drilling rigs
the world’s DCUs tools from slumped beds • Floating production, storage and
• Complete systems with virtually all offloading vessels
equipment needed to operate and Advanced Cutting Control • Drill ships
control the hydraulic decoking process • Complete systems and enclosures • Crane vessels and pipelay vessels
• Extensive aftermarket support to monitor and control the operations
including specialists to evaluate • Continuous feedback signals Features
system performance, improve indicate equipment and drum status • Up to 5 m (16.5 ft) propeller diameter
reliability, and recommend operational (i.e., position in drum, rotational • Up to 4500 kW (6000 hp) input
and safety best practices speed, wore rope tension, etc.) • 4- or 5-blade fixed pitch propeller
• Embedded intelligence to process • 7° tilted propeller shaft
Complete Coke Cutting Systems data for monitoring and control; −−Propulsion and steering with thrust
• Jet pump train: ISO 13709/API 610 operator interface only required in any direction
(BB5) jet pump, driver, lube oil skid for sequence exception −−Minimal thruster-hull and
and control system panel • Video and acoustic equipment to thruster-thruster interaction for
• Coke cutting system: decoking monitor cutting deck operations and higher net thruster output
control valve, AutoShift™ combination coke chute conditions −−Mounting and dismantling
cutting tool, rotary joint, isolation and • Remote winch and rotary joint underwater without dry-docking
bleed valves, drill stem, tool guide and operation −−Customization to meet specific
enclosure and high-pressure hose • Remote sensing of cutting jet application needs
• Cutting assembly lifting system: impingement on the coke drum • Duplex thrust bearing allows
crosshead, free-fall arresters, winches • Interlocking safety systems windmilling at any speed
and winch controls, pulley blocks, • IPS APEX™ data monitoring, • Automatic pressure compensation
and latch mechanism to stow transmission and control systems system adapts differential pressure
the crosshead to draft
• Automation, controls and Online Assurance Programs • Fully flooded gear housing provides
instrumentation • Access to data aggregation tools via optimum lubrication
the Technology Advantage™ Portal • Easy underwater mounting; secured
AutoShift Combination Cutting Tool • Enable experts to monitor, diagnose during installation by hydraulically
• Removes the operator from the and communicate operating operated locking mechanism
cutting deck solutions to increase unit uptime • Fully redundant closed-loop hydraulic
• Mode shifting is accomplished steering system as standard
automatically and remotely by water See Bulletin PS-90-6
pressurization and depressurization See Bulletin PSS-90-8.1
63
DWEER TM ERT CVP
Dual Work Exchange Energy Recovery Turbine Vertical, Concrete Volute
Energy Recovery
Overhung Products
Specialty – General
– Others
Industry

Standards Standards Standards


• Flowserve • Flowserve • Flowserve
• Hydraulic Institute
Operating Parameters Operating Parameters
• Brine flows to 350 m3/h (1.4 mgd); • Brine flow to 1200 m3/h (5280 gpm) Operating Parameters
greater flows can be achieved • Pressures up to 80 bar (2715 ft) • Flows to 115 000 m3/h (500 000 gpm)
by placing multiple DWEER units • Efficiency up to 90% • Heads to 45 m (147 ft)
in parallel • Power to 1500 kW (2025 hp)
• Pressures to 75 bar (1090 ft) • Special designs available on request Features
• Vertical dry-pit design
Features Features • Removable metallic pump pullout
• Highest efficiency energy recovery • Especially designed for sea water unit within a concrete volute
device available reverse osmosis (SWRO) applications • Suction bell connected to preformed
• Noise levels below 83 dBa • Standardized product line high efficiency, vortex-free concrete
• Self adjustable to changing operating • Wetted parts in super duplex suction box
conditions stainless steel and non-metallics • Open mixed flow and closed mixed
• Super duplex stainless steel or fiber • Proven long-term reliability – over 25 flow impeller options
reinforced plastic pressure vessel years operating experience • Dry shaft design
• No leakage/lubrication required • Simple plant integration and control • No submerged bearings
• Patented LinX™ valve regulates • Horizontal split casing • Bearings and sealing systems
flow into vessels • External standard bearings easily accessible
• Proven long-term reliability • Labyrinth double seals • Prefabricated concrete segments
• Capable of passing solids/debris • Flat operating curve over typical RO • Highly corrosion and erosion resistant
(no additional strainers required) performance range • Liquidyne® or mechanical shaft seal
• System responsibility with • No mixing, overflush or leakage • Inflatable static seal
integrated controls • Engineered to customer specifications
• Slow operating speed See Bulletin FPD-18
• Smooth increase and decrease of Available Configurations
system pressure during startup and • BSV open mixed flow impeller design
shutdown • BCV closed mixed flow impeller design

See Bulletin FPD-18 See Bulletin PS-40-1


® Liquidyne is a registered trademark of IHC

64
Barge Pump Molten Salt VTP

Overhung Products
Specialty – General
– Others
Industry
Standards Standards
• Flowserve • Flowserve

Operating Parameters Operating Parameters


• Flows to 1020 m3/h (4500 gpm) • Flows to 13 600 m3/h (60 000 gpm)
• Heads to 185 m (600 ft) • Heads to 530 m (1740 ft)
• Pressures to 8.6 bar (125 psi) • Pressures to 100 bar (1450 psi)
• Temperatures from -30°C (-20°F) • Temperatures to 600°C (1100°F)
to 230°C (450°F) • Settings to 20 m (65 ft)
• Discharge flanges to 250 mm (10 in)
Features
Features • Low pump submergence allows for
• Pollution prevention design greater energy generation
• Discharge head with access ports • Low NPSHr for enhanced suction
• Rabbeted fit motor shaft performance
to headshaft • Excellent heat dissipation prevents
• 1.5 m (5 ft) column pieces with distortion at high temperatures
integrally fabricated bearing support • Advanced fluid sealing system
• Automatic stuffing box bleed-off • Materials engineered to equalize
and valved drain line thermal growth and forestall distortion
• Special low NPSH priming • Wet pit or tank mounted
stage impeller • Dynamically balanced enclosed
• Semi-open series stage impeller impellers
• Automatic air separation chamber • Flanged column pipe with open
with continuous seal lineshaft construction
• Product lubricated bearings
See Bulletin PSS-40-7.2 • Cooling fan/disc
• Drain tubes
• Other options
−−Integral axial thrust bearing
−−Thrust balanced impeller
−−Coupling bellows
−−ISO 13709/API 610 construction

Related Configurations
• FRBHJC cantilever sump
• CPXV chemical sump

See Bulletin FPD-16 65


Additional Information
Integrated Solutions Group 68
Other Flowserve Products 70
Reference Sources 71

Additional Information

67
Flowserve Integrated Solutions Group
Reduce life cycle costs. It’s About the Bottom Line
Manage assets more efficiently. Flowserve ISG helps customers take advantage
of a focused set of aftermarket capabilities and
Increase plant uptime. technologies developed to derive greater value from
their plant investments. Through the application of
Enhance workforce skills. engineering know-how, industry-specific expertise,
comprehensive training capabilities and advanced
technologies, Flowserve helps customers focus on
Whether in a refinery, power plant or chemical the issues that have the greatest potential to improve
their bottom lines.
complex, these ideas are taking hold as plant
operators intensify their focus on maximizing
Flowserve ISG helps customers achieve:
plant profitability. Historically, applying these con-
• Plant output optimization through increased
cepts to pumps and pumping systems has been equipment availability
achieved through reactive aftermarket programs. • Energy reductions at the plant, unit or
The Flowserve Integrated Solutions Group (ISG) is equipment level
dedicated to helping customers proactively apply • Equipment optimization by increasing mean
the principles of life cycle cost savings, asset opti- time between repair (MTBR) or by optimizing
performance for actual system requirements
mization and equipment availability to pumps and
• Workforce skill set development for technical,
pumping systems. maintenance and operations resources
• Environmental protection
• Safety and health protection
• Cost reductions through inventory and
procurement optimization

No two situations are the same, so ISG tailors


its solutions and programs to help each customer
realize the full potential of its assets.

68
flowserve.com

To help customers achieve maximum value from their Business Consulting


investments, Flowserve ISG offers a comprehensive Flowserve ISG Business Consultants help customers
set of aftermarket services and programs. identify savings opportunities associated with business
and operational processes. Typical engagements
Technical Services focus on procurement efficiency, inventory optimiza-
A global team of more than 150 design and applications tion and high-level performance analyses and com-
engineers is focused exclusively on helping customers pare business performance metrics to established
maximize operational performance and plant profitability. industry benchmarks. Implementation plans with
With access to diagnostic technologies, testing facilities, cost justifications provide customers with a roadmap
mechanical and hydraulic engineering tools, and for achieving identified savings and efficiency gains.
numerous support resources, this team performs
exhaustive system assessments and implements
solutions based on life cycle cost justifications. Technology Advantage™
• Technical assessments of pumps and systems Whether temporarily employed for data
for reliability and energy consumption acquisition or permanently deployed as part of
• Equipment upgrades, re-rates and retrofits an asset management program, Technology
• Energy reduction and bad actor programs Advantage solutions allow customers to easily
access, acquire and interpret data while also
Asset Management incorporating industry-leading diagnostics.
Flowserve can help customers proactively manage This platform includes important capabilities
their plant assets. Flowserve ISG offers various levels such as:
of asset management capability, from point-specific
• Equipment monitoring via wired and wireless
equipment monitoring to comprehensive management
systems with simple integration to plant
solutions with equipment records, drawings, real-time
control systems
operational data and decision workflows.
• Diagnostics technologies with intelligent,
Education and Training application-specific algorithms that predict
Educational Services offers a wide range of programs equipment behavior and fault conditions
that help plant operators, reliability engineers and • System optimization and control technologies
maintenance personnel deepen their understanding that respond to user-defined process
of pumps and pumping systems. parameters and adjust equipment operation
• Maximize plant asset availability and reliability to optimized or safe duty points
• Increase mean time between repair (MTBR) • Data visualization and asset management
• Improve proficiency in the installation, maintenance tools through the Technology Advantage Portal
and repair of pumping equipment and systems
69
Providing Complete
Fluid Motion
Control Equipment
and Services

Other Flowserve Products


Flowserve has the systems, products and Flowserve Valves
experience to help processes run smarter, safer With the industry’s most complete range of valves,
and more efficiently. In addition to its extensive actuators, positioners, controls, switches and steam
pump product line, Flowserve offers high-quality systems, Flowserve provides customers a one-stop
solution for their flow control needs.
seals and valves.
With comprehensive research and development,
engineering and global support, Flowserve valves
Flowserve Seals offers valve applications solutions from simple
Flowserve manufactures and markets highly engineered isolation service to intelligent process control.
mechanical shaft seals for containing corrosive, volatile, To learn more about Flowserve valves and seals,
abrasive, precious or flammable fluid. They are used on visit www.flowserve.com.
pumps and other rotating equipment.
The complete seal line includes cartridge, dry-running,
metal or elastomer bellows, split and zero emission gas
barrier seals. Offering innovative seal design and
service on demand, Flowserve is
committed to the development of
new technologies to further reduce
maintenance and operating costs
for its customers.

70
flowserve.com

Reference Sources
Pump Industry Standards Cameron Hydraulic Data
To learn about industry standards pertaining to the First published in 1926 and now in its 19th edition,
design and performance of pumps contact the following the Cameron Hydraulic Data book is an indispens-
organizations: able aid to engineers involved with the specification,
• American Petroleum Institute (API) selection and application of pumping equipment.
www.api.org This comprehensive reference tool includes:
• Hydraulic principles and formulae
• American Society of Mechanical Engineers
• Friction data
(ASME – ANSI) www.asme.org
• Properties of common liquids
• American Society of Testing and Materials (ASTM) • Steam and electrical data
www.astm.org • Weights, dimensions, and ratings of pipe
• European Sealing Association (ESA) flanges and fittings
www.europeansealing.com • Metric conversions
• Europump To obtain a copy of the Cameron Hydraulic Data
www.europump.org book visit: www.cameronbook.com.
• Deutsches Institut für Normung (DIN)
www.din.de/ Pump Engineering Manual
• Fluid Sealing Association (FSA) This publication is devoted to explaining centrifugal
www.fluidsealing.com pump principles. It covers the basics from applica-
• Hydraulic Institute (HI) tion analysis and affinity laws through hydraulics
www.pumps.org and mechanical phenomena to troubleshooting.
• International Organization for Standardization (ISO) To obtain a copy of the Pump Engineering Manual
www.iso.org visit: www.cameronbook.com.

PROS+
PROS+ proposal and order system is the most compre-
hensive and user-friendly pump selection program in
the industry. This software ensures correct sizing and
selection of Flowserve pumps to best suit your process
application needs.
PROS+ is available from your local sales representative
or on-line at www.flowserve.com. 71
Index

A L
DVSR (nuclear) . . . . . . . . . . . . . . . . . . . . . . . 59
AFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
DVSS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
APKC (See APKD). . . . . . . . . . . . . . . . . . . . . . . 43 LLR (See LR). . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DWEER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
APKD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 LNN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
E LR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
B LRV (See LR). . . . . . . . . . . . . . . . . . . . . . . . . . . 28
EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Barge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 LPN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
ECPJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
BCV (see CVP). . . . . . . . . . . . . . . . . . . . . . . 41, 64
EG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
BP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 M
ERPN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
BSV (see CVP). . . . . . . . . . . . . . . . . . . . . . . 41, 64 M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
ERT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Byron Jackson SUBM (Oil-Filled Design). . . 44 Mark 3 ASME Standard. . . . . . . . . . . . . . . . 10
ESP3 Chemical Sump . . . . . . . . . . . . . . . . . 48
Mark 3 In-Line . . . . . . . . . . . . . . . . . . . . . . . . 11
C F Mark 3 Lo-Flo. . . . . . . . . . . . . . . . . . . . . . . . . 10
CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Mark 3 Recessed Impeller . . . . . . . . . . . . 11
F-Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
CAM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Mark 3 Unitized Self-Primer. . . . . . . . . . . 10
FRBH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
CAV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 ME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
FRBHJC . . . . . . . . . . . . . . . . . . . . . . . . . . . 21, 46
CHTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MEN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 G MENBLOC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CPX3 Close Coupled. . . . . . . . . . . . . . . . . . . 13 GA Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 MEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
CPX3 ISO Standard. . . . . . . . . . . . . . . . . . . . 12 Gearex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 MF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
CPX3 Self-Priming . . . . . . . . . . . . . . . . . . . . 12 GR Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 MFV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
CPX3 Recessed Impeller . . . . . . . . . . . . . . 12 Guardian. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 MJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
CPXS Magnetic Drive. . . . . . . . . . . . . . . . . . 13 MJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
CPXV Chemical Sump. . . . . . . . . . . . . . 13, 48 H MN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
CS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 HDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MNV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
CSB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 HDO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 MND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
CVP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41, 64 HDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 MNR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
HDX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Molten Salt VTP. . . . . . . . . . . . . . . . . . . . . . . 65
D HDX-TT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 MP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
D800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 HED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 MP1 Systems Packaging . . . . . . . . . . . . . . 53
DFSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 HED-DS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 MPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
DMX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 HPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Drain-Titan. . . . . . . . . . . . . . . . . . . . . . . . 47, 49 HPXM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MSP2 (See MSP). . . . . . . . . . . . . . . . . . . . . . . . 18
DS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 HS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 MSX. . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 44, 47
DSVP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 HSB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MVE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
DVSH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 HSO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 MVX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
DVSR (non-nuclear). . . . . . . . . . . . . . . . . . . 31 HWMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
HWMA2 (See HWMA). . . . . . . . . . . . . . . . . . . . 17
72 Hydraulic Decoking Systems. . . . . . . . . . . 63
flowserve.com

N S W
NM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 WCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
N-Seals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 SMX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 WD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SUBM WDF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
P (See Bryon Jackson SUBM or Pleuger SUBM) . . 44 WDX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
PHL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 WFSD Thruster
Pleuger SUBM (Water-Filled Design) . . . . 44 (See Pleuger WFSD Azimuthing Thruster) . . . . . 63
T
Pleuger WFSD Azimuthing Thruster. . . . 63 WIK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Terra-Titan. . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Polybase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 WMA (See HWMA) . . . . . . . . . . . . . . . . . . . . . . 17
Titan Slurry. . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PolyChem GRP . . . . . . . . . . . . . . . . . . . . . . . 14 WMA2 (See HWMA). . . . . . . . . . . . . . . . . . . . . 17
TKW Cryogenic Liquid Expander. . . . . . . 62
PolyChem M-Series. . . . . . . . . . . . . . . . . . . 15 WNC-HP (See WNC). . . . . . . . . . . . . . . . . . . . . 35
TSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
PolyChem S-Series. . . . . . . . . . . . . . . . . . . . 14 WNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PolyChem VGRP . . . . . . . . . . . . . . . . . . . 14, 48 U WTB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Polyshield . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 WUC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
UZDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PVML. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 WUC-LNG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
PVXM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 V WUJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 WX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Q WXB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
VCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
QL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 WXB-B (See WXB) . . . . . . . . . . . . . . . . . . . . . . 35
VKW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
QLC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 WXH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
VPC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
QLQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
VQE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
QLQC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Y
VSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
YHT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
R VSMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
VTE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
VTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
RJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
RJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

73
USA and Canada
Flowserve Corporation
5215 North O’Connor Blvd.
Suite 2300
Irving, Texas 75039-5421 USA
Telephone: 1 937 890 5839

Europe, Middle East, Africa


Flowserve Corporation
Gebouw Hagepoint
Westbroek 39-51
4822 ZX Breda
Netherlands
Telephone: 31 76 502 8920

Latin America
Flowserve Corporation
Boulevard del Cafetal
Edificio Ninina, Local 7
El Cafetal - Caracas
Venezuela 1061
Telephone: 58 212 985 3092
Telefax: 58 212 985 1007

Asia Pacific
Flowserve Pte. Ltd.
10 Tuas Loop
Singapore 637345
Telephone: 65 6771 0600
Telefax: 65 6779 4607

Bulletin FPD-100f (E/A4) Printed in USA. March 2010. © Flowserve Corporation

To find your local Flowserve representative:

For more information about Flowserve Corporation,


visit www.flowserve.com or call USA 1 800 728 PUMP (7867)

flowserve.com

You might also like