Before using a bonding tester, the 6 foot lead has the two prongs shorted
1.
together with a piece of metal. What would the indicator read?
View Test Results When using a megger to test insulation resistance, capacitive filters should
2.
be disconnected for what reason?
Order Modules Your Answer: Remove the risk of damage to the megger INCORRECT
Correct Answer: Prevent damage to the filters
Tutorial Support This question has been asked 494 times with a success rate of 54 percent.
Comment/Reference: Leaflet 9-1 4.4.4 e AandP Mechanics General Handbook Pg
Study Notes 351
Report problem
Logout with question
Send your reference
Store this
question
http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 2 of 4
Report problem
with question
Send your reference
Store this
question
Report problem
with question
Send your reference
Store this
question
When using a digital meter to test a diode, a correct operation of the diode is
5.
indicated by a volt drop of
Your Answer: 1.5V to 2V INCORRECT
Correct Answer: 0.3V to 0.7V
This question has been asked 445 times with a success rate of 89 percent.
Comment/Reference: Forward voltage drop of a diode is 0.2V (germanium) or
0.6V (silicon).
Report problem
with question
Send your reference
Store this
question
A pressure gauge is fitted to a Dead Weight Tester. The piston area is 0.25
sq.in. and the total mass of the mass carrier and masses is 5lb. If the
6.
pressure gauge is accurate what pressure in pounds per square inch (PSI)
will it read?
Your Answer: 20psi CORRECT
This question has been asked 446 times with a success rate of 73 percent.
Comment/Reference: Pressure = Force / Area = 5/0.25 = 20 PSI
Report problem
with question
Send your reference
Store this
question
http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 3 of 4
Report problem
with question
Send your reference
Store this
question
Report problem
with question
Send your reference
Store this
question
A fuel calibration test set when used to check an aircraft with half a fuel
10.
load is connected
http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 4 of 4
General Links
--- Privacy Policy | Terms and Conditions | Contact | Equal Opportunities and Diversity | Quality Policy
Copyright © 2012 Total Training Support. All Rights Reserved.
http://club66pro.com/sequentialtest.php 1/17/2012