Members Area View Result Breakdown

Before using a bonding tester, the 6 foot lead has the two prongs shorted
1.
together with a piece of metal. What would the indicator read?

Your Answer: Zero at the centre INCORRECT


Correct Answer: Full scale right
 
This question has been asked 484 times with a success rate of 68 percent.
Members Home
Comment/Reference: Leaflet 9-1 3.10.2 a Infinity is full scale to the right.
My Personal Details
Report problem
with question
My Control Panel
Send your reference
Store this
Take a Test
question

View Test Results   When using a megger to test insulation resistance, capacitive filters should
2.
be disconnected for what reason?
Order Modules Your Answer: Remove the risk of damage to the megger INCORRECT
Correct Answer: Prevent damage to the filters
Tutorial Support This question has been asked 494 times with a success rate of 54 percent.
Comment/Reference: Leaflet 9-1 4.4.4 e AandP Mechanics General Handbook Pg
Study Notes 351
Report problem
Logout with question
Send your reference
Store this
question

http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 2 of 4

When carrying out a serviceability check on a bonding tester - short together


3.
the three prongs of both probes and ensure which of the following?
Your Answer: A full scale reading is obtained INCORRECT
Correct Answer: A zero reading
This question has been asked 465 times with a success rate of 72 percent.
Comment/Reference: Leaflet 9-1 3.10.2 (b)

Report problem
with question
Send your reference
Store this
question

If an insulation resistance tester is operated and the leads are suspended in


4.
free air, what will the meter read?
Mid scale - it is a ratiometer movement and there is no
Your Answer:
current flowing in the external circuit INCORRECT
Correct Answer: Infinity
This question has been asked 435 times with a success rate of 79 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

When using a digital meter to test a diode, a correct operation of the diode is
5.
indicated by a volt drop of
Your Answer: 1.5V to 2V INCORRECT
Correct Answer: 0.3V to 0.7V
This question has been asked 445 times with a success rate of 89 percent.
Comment/Reference: Forward voltage drop of a diode is 0.2V (germanium) or
0.6V (silicon).
Report problem
with question
Send your reference
Store this
question

A pressure gauge is fitted to a Dead Weight Tester. The piston area is 0.25
sq.in. and the total mass of the mass carrier and masses is 5lb. If the
6.
pressure gauge is accurate what pressure in pounds per square inch (PSI)
will it read?
Your Answer: 20psi CORRECT
This question has been asked 446 times with a success rate of 73 percent.
Comment/Reference: Pressure = Force / Area = 5/0.25 = 20 PSI

Report problem
with question
Send your reference
Store this
question

7. When testing a fuel metering unit, how is it checked?


Your Answer: With the meter in parallel with the unit INCORRECT
Correct Answer: With the meter in series with the unit
This question has been asked 464 times with a success rate of 66 percent.
Comment/Reference: A fuel metering unit is checked with the fuel meter in series
with the meter under test. No reference found
Report problem
with question

http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 3 of 4

Send your reference


Store this
question

8. When using a bonding tester


Your Answer: an anodised component cannot be tested INCORRECT
Correct Answer: ensure prongs penetrate anodised layer
This question has been asked 457 times with a success rate of 86 percent.
Comment/Reference: Leaflet 9-1 Para.3.10.6

Report problem
with question
Send your reference
Store this
question

9. On a static leak tester, pressure is released by


Your Answer: an internal balance valve in the tester INCORRECT
Correct Answer: a bleed valve in the tester
This question has been asked 448 times with a success rate of 73 percent.
Comment/Reference: (No Comment/Reference Available)

Report problem
with question
Send your reference
Store this
question

A fuel calibration test set when used to check an aircraft with half a fuel
10.
load is connected

Your Answer: to gauge with fuel level in parallel INCORRECT


Correct Answer: to gauge with fuel level in series
This question has been asked 463 times with a success rate of 64 percent.
Comment/Reference: The test set is connected in series with the fuel level
conditioner
Report problem
with question
Send your reference
Store this
question

Continue with Next 10 Questions

Module Specific Links

All About Circuits Digital electronics tutorials


Arinc 429 tutorial PDF - Allow it to load in the pop-up, then click Save, to save it to
your computer for off-line reading.
Collins Avionics Glossary All the Avionics acronyms. Download PDF.
Fibre Optics Theory and Hardware site Perfect for Chapter 5.10 CAA Acronyms
Gore Fibre Optics and Terms
Inertial Navigation A superb document about the design, function, operation,
errors etc. of all types of INS and IRS including the workings of the Ring Laser
Gyro.
Play Hookey Great theory site for Modules 3, 4 and 5
STD-MIL-1553 Tutorial PDF - Allow it to load in the pop-up, then click Save, to
save it to your computer for off-line reading.
Tech Topics Fibre Optics Basics
Trimble GPS tutorials

http://club66pro.com/sequentialtest.php 1/17/2012
club66 professional - Sequential Test Page 4 of 4

Do you know of any good study websites for this module?


Tell us about them and we will post them here.

General Links

A+P Advisory Civil Aircraft


airtech Part-66 Ask a Subject
Mechanics Circular Inspection
books.com syllabus Specialist
Handbooks 43 Procedures

--- Privacy Policy | Terms and Conditions | Contact | Equal Opportunities and Diversity | Quality Policy
    Copyright © 2012 Total Training Support. All Rights Reserved.

http://club66pro.com/sequentialtest.php 1/17/2012

You might also like