ACDHUM - Air Change


Dehumidification Unit
First Australian made Dehumidification Unit
with air to air counterflow plate heat exchange
technology for temperature and humidity control.

DX Packaged Unit 200-5000 L/s


Chilled Water Unit 200-6000 L/s

• Heat exchange technology enables


pre-cooling and re-heating
• Higher efficiency and superior humidity control
over standard systems
• Achieves high COP
• Advanced Control System as standard
• Complete packaged design
• No return air required – 100% pressurisation
• Improves indoor air quality with up to 100% outdoor air
• Multi award winning Australian made, internationally
patented technology

Australian Innovation at its best

airchange.com.au
ACDHUM
Features & Benefits

Air Change Dehumidification Unit - DX or Chilled Water


The specialised ACDHUM range is designed to provide a more energy efficient and cost effective
solution for handling high latent loads.
The ACDHUM unit efficiently pre-conditions the temperature and humidity of the building fresh air supply.
The system is an ideal solution for situations where exhaust air cannot be recovered or used due to spill
air contamination, building pressure requirements or the practical constraint of recovering exhaust air.
Although it has been designed for hot and humid environments the ACDHUM is not only limited to that,
it can be effectively used all year round. During winter or mild temperatures the reverse cycle capability
provides efficient operation in heating mode.
Product Range
• DX Units from 200–5000L/s • Chilled Water Units from 200–6000L/s

Backward curve fans

Built-in high
High static fan
grade air filters
*EC Plug Fan (standard
for ACDHUM1)

Advanced Control
System (BACnet
compliant) allows for High efficiency
virtual plug and play sensible only air to air
counter-flow plate heat
exchanger

Variable speed
compressors

Direct coupled
fan & motor

Scroll compressors

Upgraded compressors Standard


for extra refrigeration Optional
capacity

• Air to air counterflow plate sensible heat exchanger enables pre-cooling and re-heating
• Advanced Control System (BACnet compatible) as standard
• No return air required - 100% pressurisation
• High COP - average measurement of 6 in an onsite situation and 10 under peak design conditions
• Supplies 100% outdoor air for optimal IAQ
• Complies with Section J of BCA
• Complete packaged and factory tested units, with guaranteed performance
• Assists with earning Green Star points and improves NABERS energy rating
• Australian made, designed and patented award winning heat exchange technology
How it works

The ACDHUM system will cool and dehumidify hot and humid outside air to the supply air set point
condition. In the cooling mode (see schematic below) outside air (1) is pre-cooled and dehumidified
as it passes through the air to air sensible heat exchanger (2). The air is further cooled and
dehumidified as it passes over the cooling coil (3) before being directed back through the counter
path of the heat exchanger. This supply air is reheated to supply air set point temperature (4) as it
passes back through the heat exchanger and its condition can be precisely trimmed via the bypass
damper. The main source of energy efficiency is attributed to the heat exchanger, as only fan energy
ines
is required to pre cool and reheat the supply air.
Project: Brigidine Street Contact: James Aye

Psychrometric Chart
Psychrometric Chart ACDHUM schematic

1
4

2 1

3
4 2

SA Fan Bypass Damper Cooling Coil Drain Tray HX (Sensible) Bag Filter
Modulating

5 Point
10
15 20 25Location 30 Sydney
35 Brisbane
40 45 North 50Adeilade Melbourne Darwin Perth
Dry Bulb Temperature (°C) Queensland
1. Outside Air Tdb/Twb (°C) 35.5/24 33.5/26 34.5/27.5 40/23 37.5/21.5 34.5/28 40/23
Shane Carmichael
2. Air Off Heat Exchanger Cooling Tdb/Twb (°C) 25.5/21 23.5/23.5 25/25 29/20 26.5/18.5 27.5/25.5 29/20

3. Air Off Coil Tdb/Twb (°C) 13/13 13/13 13/13 13/13 13/13 13/13 13/13

4. Supply Air After Reheat Tdb/Twb (°C) 24/17 24/17 24/17 24/17 24/17 24/17 24/17 Installations

Gold Coast University Hospital, QLD Aldi QLD & NSW Brisbane City Hall, QLD Coles, Cannon Hill, QLD
Consultant SKM (various stores) Consultant EMF Griffiths Consultant DMA Professional
Installation Hastie Air Conditioning Consultant DMA Installation Siganto Engineers
13 various ACDHUM6-W, Professional Engineers and Stacey Installation Cool Air Solutions
ACDHUM7-W & ACDHUM8-W ACDHUM2-W & ACDHUM2-D
ACDHUM3-W

Multi Award Winning Technology


ARBS Industry Awards “ESD Product” Winner 2010
AIRAH “Excellence in HVAC” Winner 2003 (Qld) & 2006 (National)
SEDA “Green Globe” Winner 2002 & 2003
Technical Data
Dehumidification Units
Model No ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM ACDHUM
1-D 2-D 3-D 4-D 5-D 6-D 7-D 1-W 2-W 3-W 4-W 5-W 6-W 7-W 8-W

Supply Air Nominal Flow Rate (L/s) 720 850 1100 1700 2400 3500 4000 720 850 1100 1700 2400 3500 4000 5000

External Static (Pa) < 150 < 200 < 250 < 150 < 200 < 250

Compressor Capacity 26 51 67 88 114 140 165 N/A

Energy Reclaim# kWr) Precool 9.5 11.3 14.6 22.6 31.8 46.4 53.1 9.5 11.3 14.6 22.6 31.8 46.4 53.1 66.3

Reheat 9.5 11.3 14.6 22.6 31.8 46.4 53.1 9.5 11.3 14.6 22.6 31.8 46.4 53.1 66.3

Total 19 22.6 29.2 45.2 63.6 92.8 106.2 19 22.6 29.2 45.2 63.6 92.8 106.2 112.6

Heat Exchanger Energy Savings 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4% 48.4%

Compressor Type 1 2 N/A

Refrigerant R407C N/A

Fan Type 3 Phase Direct Couple Motor/Fan - VSD Controlled

Volts/ph/Hz 415 / 3 / 50

Construction 50mm sandwich panel, 0.6mm clad colourbond both sides. UV treated polymer joiners for maximum strength, insulation and durability

Weight (kg) 640 975 1315 1743 2074 2536 2820 350 682 909 1211 1491 1834 2075 2424

# Data based on ambient 35.5°C/24°C and supply 24°C/17°C at nominal flow rate with 100% Outdoor Air.
Specifications subject to change without notice.

ACDHUM Schematic
A A
B B

C
C

ACDHUM - D ACDHUM - W

Dehumidification Unit Dimensions


ACDHUM - D ACDHUM - W
Size A (Width) B (Depth) C (Height) A (Width) B (Depth) C (Height)

1 1450 2590 2325 950 2590 1860

2 2100 2490 2325 1600 2490 1990

3 2750 2490 2325 2250 2490 1990

4 3550 2490 2375 2900 2490 1990

5 4200 2490 2375 3550 2490 1990 Contact Air Change engineers
6 4850 2490 2450 4200 2490 2040
for technical information or visit
7 5500 2490 2450 4850 2490 2040 www.airchange.com.au
8 N/A N/A N/A 5500 2490 2040

airchange.com.au
Offices NSW 02 9531 4699 VIC 03 9482 1010 QLD 07 3891 1974
Distributors NTH QLD 07 4775 5222 SA/NT 08 8354 0088 WA 08 9367 3288 TAS 03 6344 6888 New Zealand +64 3 343 6184
Air Change products internationally patent protected I Refrigerant Trading Authorisation No: AU23586 ACDHUM 2012

You might also like