GOVERNMENT OF MADHYA PREDESH

PUBLIC HEALTH ENGINEERING DEPARTMENT

UNIFIED SCHEDULE OF RATES


FOR
WATER SUPPLY, SEWERAGE
AND ALLIED WORKS

IN FORCE FROM
rd
3 July 2018

Issued
By

Engineer in Chief
Public Health Engineering Department
Bhopal, Madhya Pradesh

Price : 500/-
CONTENTS

CHAPTER PARTICULARS PAGES NO.


NO. FROM-TO
1 PREFACE 1
(A) WATER SUPPLY & SEWERAGE WORKS 2
2 GENERAL NOTES 3 -6

I Cast Iron Pipes & Specials with Socket & Spigot 7 - 26


Joints (Lead Joint)
II Cast Iron Tyton Pipes with Tyton Joints 27 - 30
III Cast Iron Pipes & specials with Flanged Joints 31 - 48
IV Ductile Iron Pressure Pipes & Specials with Tyton 49 - 74
Joints

V Asbestos Cement Pressure Pipes & Cast Iron 75 - 84


Fittings

VI Galvanised Iron Pipes, Gun Metal / Brass Valves 85 - 103


and Fittings

VII PVC Pipes & Fittings 104 - 109

VIII Cast Iron Valves 110 - 116

IX HDPE pipe, MDPE pipe & Specials 117 - 132

X Mild Steel Pipes and Specials 133 - 143

XI Bar Wrapped steel cylinder pipes (BWSC) 144 - 156

XII Stone Ware Pipes for Sewers 157 - 164

XIII Reinforced Cement Concrete Pipes 165 - 174

XIV Double Wall Corrugated (DWC) Pipes 175 - 178

XV Sewer Appurtenances 179 - 195

XVI Allied Civil Works 196 - 217


XVII General Miscellaneous 218 - 232

(B) CONSTRUCTION OF TUBEWELL & 233


ALLIED WORKS
3 GENERAL NOTES 234 - 238

XVIII Resistivity survey 239 – 240

XIX Construction of ordinary tube well 241 – 243

XX Construction of gravel packed tube well 244 – 246

XXI Installation of hand pump, construction of 247 – 249


platform, drain and soakage pit

XXII Development, yield test and disinfection of tube 250 – 251


well

XXIII Odex Type of Tube well 252 – 253

XXIV Miscellaneous Item of Tube well 254 – 268

Annexure 1- Issue rates 269


Annexure 2- Strata chart proforma 270

Annexure 3- Resistivity survey report proforma 271 – 272

Annexure 4- Yield test report proforma 273-274

(C) SEWERAGE MAINTENANCE WORKS 275

4 GENERAL NOTES 276

XXV Sewerage maintenance 277 – 284

5 DRAWINGS 285 - 303


PREFACE

The Unified Schedule of Rates for Water Supply, Sewerage and Allied works
were made applicable in Public Health Engineering Department for the entire state of
Madhya Pradesh as “Unified Schedule of Rates” which was enforced form 1st June
2016. As two years have passed since the issue of this USOR and meanwhile the new
taxation system in the form of Goods & Service Tax (GST) has also been enforced
from 1st July 2017.This has substantially effected the rates of all the items of the
USOR. So, it was necessary to revise the USOR looking to the hike in the prices of
materials and labour etc. involved in above works and segregate the GST portion to be
paid separately over and above the USOR rates as per the prevailing government
norms from time to time.

This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the contractor
in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross amount.

This Unified Schedule of Rates for all the works related to the Public Health
Engineering Department has been revised to facilitate the preparation of realistic
estimates and bringing uniformity in the rates and specifications of various type of
works to be executed by the Public Health Engineering Department in Madhya
Pradesh.

I extend my thanks to Shri Ashok Baghel, Chief Engineer (E&M), Shri C.K.
Singh, Shri R.K. Hirodiya, Superitending Engineers; Shri P.K. Raghuvanshi, Shri Alok
Kumar Jain, Shri Ajay Diwakar, Shri Sunil Kumar Chaturvedi, Shri Udit Garg,
Executive Engineers; Shri R.K. Chawla, Shri C.S. Kawalkar, Shri Sunil Shakargaye,
Shri C.B. Magarde, Shri J.P. Ganote, Assistant Engineers; Shri Rajendra Kumar
Shrivastava, Shri Priyank Patel, Sub Engineers; Shri Mahesh Pal Computer Operator
Shri Suresh Jasutkar, Stenographer for their commendable efforts in preparing this
schedule of rates.
This Unified Schedule of Rates (USOR) for the work of Water Supply,
Sewerage and Allied works shall come in to force from 3rd of July 2018.

(K.K. Songaria)
Engineer-In-Chief
Public Health Engineering Department
Madhaya Pradesh, Bhopal

1
PART - (A)

WATER SUPPLY
&
SEWERAGE WORKS

2
UNIFIED SCHEDULE OF RATES
GENERAL NOTES
WATER SUPPLY AND SEWERAGE WORKS
1. Definitions:
The following terms and expressions wherever they appear in the schedule of
rates shall have the meaning and implications assigned to them.
(i) Engineer in Charge:- Engineer in Charge would refer to the Executive
Engineer of Public Health Engineering Division in charge of work.
(ii) Diameter:- Diameter of pipes, specials, valves etc. shall be the nominal
internal diameter of the bore except for PVC pipe for which the diameter of
pipe will denote the outer nominal diameter of pipe . These would be as per
IS codes.
(iii) Providing & Fixing:- The provision of all materials and labour and the
performance of all workmanship together with the use of all materials and
labour, transport, tools, plants, appliances and all other provisions necessary
for the proper execution of work as described in the concerned item of
schedule of rates and the provision and uses of all coverings or casing etc.
necessary to protect the work from inclement weather etc. and from damages
from falling materials or other causes and all required safety arrangements.
(iv) Laying and Fixing only:
As defined, for 'providing and fixing' except the provision of the materials
(which will be supplied free of cost by the department for incorporation in the
work) to be fixed or laid, but including taking supply of the articles from the
Public Health Engineering Department Stores and the provisions of materials
necessary for the proper execution of the work as described in the item of
schedule of rates which are subsidiary to, but are not supplied as part of the
principal articles such as bolts, nuts, packing, jointing materials etc, and the
like unless other-wise specifically excluded and mentioned in the tender
documents.
This also include testing, closing, preparing, loading and returning empty
cases, containers, bags & baggage of the articles provided by the Department
if any, to the place of issue without any extra charges.
(v) Loading and unloading of pipe :-
During unloading, the pipe shall not be drawn on hard ground and shall be
gently unloaded using proper supports without causing any damage to the
pipe etc. Unloading of pipes on timber skids without steadying rope and thus
allowing the pipe to bump against one another shall not be allowed and the
contractor shall be responsible for any damage.
(vi) Best:
With reference to quality of materials and workmanship the word ‘Best’
When used shall mean that in the opinion of the Engineer-in-Charge, there is
no superior material or article or class of workmanship obtainable in the
market.
(vii) (a) I.S.S.:
The Indian Standard Specifications as issued by the Bureau of Indian
Standards, New Delhi current and updated.

3
(b) B.S.S.
The British Standard Specifications as issued by the British Standard
Institution current and up dated.
(viii) Complete:
The provision of all such materials and labour and the performance of all
such workmanship which may be necessary for the proper execution of the
work in best workmanship manner but not particularly described in the items
of schedule of rates due to their petty nature.

2. Approval of materials:
All materials shall be used strictly in accordance with the specifications and
of the description and make as detailed in items of schedule of rate. The
quantity of the various kinds of materials to be used in the works shall in all
cases be determined by the Executive Engineer. All materials before use in
the works shall require prior approval of the Engineer-in-charge.
When materials are specified to comply with an I.S. or B.S., the contractor
shall, if required, furnish the manufactures' certificate that the materials
satisfy the requirement of the I.S. or B.S. respectively.

3. Alternative:
No alternative materials other than those specified in the agreement will
generally be allowed to be used in the works except when their use becomes
absolutely necessary in the interest of work on such grounds as non-
availability in the market due to import restrictions or any other particular
reasons beyond control of the contractor. But in all such cases, the Executive
Engineer after satisfying himself about the facts will permit in writing the use
of such alternatives and will recommend suitable alternation in rates for such
works to the competent authority. No permission for using such alternative
material shall however be granted if so mentioned in the tender documents.

4. Laying:
The approximate positions of all fittings shall generally be shown on the
plans prepared for the purpose. But it will be the sole responsibility of the
contractor to ascertain the work on the spot and the exact position where each
fitting is to be fixed from the Engineer-in-Charge before carrying out the
work.
When the pipe is closed and trench gets flooded by rain, due care shall be
taken to prevent the pipe from flooding.

5. Testing of materials:
The contractor, on completion, or whenever required by the Engineer-in-
Charge, shall prove all materials and pipes, fittings, joints and other
accessories etc. to be clear, clean, perfect in working conditions and strong
enough to withstand the test so specified here-in-under different items of the
specifications. For this purpose the contractor at his own expense, shall
provide all instruments and suitable appliances and carry out the necessary
test before the Engineer-in-Charge or his representative to his entire

4
satisfaction. The contractor shall rectify any defects as to the materials or
workmanship, so noticed, and the defective portions re-tested at his expense.
Till such time the test is completed an extra 10% of the bill amount shall be
withheld from the contractor's running bill and same will be released only
after testing, up to the entire satisfaction of the Engineer-in-Charge such
material/works shall be replaced/redone if so required by Engineer in Charge.

6. Lead:
Rates include all leads & lifts for the materials and no extra lead on account
of shifting of materials from one place to another is payable, unless it is
specifically mentioned in the contract agreement.

7. Specifications:
Work shall be executed in accordance with the specifications given in this
schedule and the specifications for works in vogue in P.H.E.D., Govt of
M.P., and the specifications attached with the 'Notice Inviting Tenders' and
the "Contract Agreement". Latest C.P.H.E.E.O. manual, published by the
Ministry of Urban Development, Govt. of India shall also be applicable. In
case of any discrepancy, the specific provision in the 'Contract Agreement'
will take precedence and the decision of the authority, sanctioning the tender,
shall be binding and final.
The materials to be used in works i.e. pipes; specials, valves etc. are to be
supplied by the departmental store, unless otherwise mentioned in the
contract document. As such, specifications for the same are not given in this
schedule of rates. In case any materials are required to be supplied by the
contractor for any particular work, materials conforming to relevant I.S.
Specification, B.S. specification, material of best quality available in the
market shall only to be used after the approval of the Engineer in Charge.

8. Civil works:
It shall be done as per specification given in chapter XII and standard IS code
for each work.

9. Safety:
The contractor shall be fully and solely responsible for making all the safety
arrangements pertaining to the work. The contractor shall be fully responsible
and liable in all respects for any accidents and subsequent legal
consequences.

10. Interpretation:
The Engineer in Chief P.H.E.D., Bhopal shall be the sole deciding Authority
as to the meaning, interpretation and implications of various provisions in
this schedule of rates. His decision shall be final and binding on all
concerned.

5
11. Award of Contract:-
The rates for various items of works given in this Unified Schedule of Rates
are based on average current market rates of materials & labour for whole of
the Madhya Pradesh State. The market rates may vary from place to place in
the State depending upon the local conditions. No contract should, therefore
be awarded directly on the rates given in this Unified Schedule of Rates
without inviting proper tenders.

12. Application of Rates for Departmental Work:-


The rates for various items of works given in this Unified Schedule of Rates
includes for 10% contractor’s profit, 1% T&P, 3% sundries and 1% water
charges. If the work is carried out Departmentally then the rates applicable
for Departmental works shall be 9.56% [(100x11)/115] less than the rates of
various items given in this Unified Schedule of Rates. The over all rate to
carry out the work departmentally shall be decided by the Superintending
Engineer of the circle based on prevailing rate in circle after deducting 9.56%
from the rates. No work shall be done departmentally unless other wise
permitted in writing by the competent authority as per manual provisions.

13. As per prevailing excise duty norms, duty exemption is on certain diameter of
Water Supply Pipes. Therefore no excise duty is considered while computing
the rates for cast iron pipes and A.C. Pressure pipe., it will be payable as per
actual on producing the necessary certificate on this account to respective
Executive Engineer of the Division where such work is executed after the
award of the contract and after obtaining full excise duty exemption as per
prevailing rules. All the concerned officers shall be responsible to get all the
prevailing exemptions in any tax or duty as per prevailing policy. The
computation of rates for D.I. pipes, S.W. pipes, R.C.C. pipe, U.P.V.C. pipes
of G.I. pipes are exclusive of excise duty and excise duty exemption shall be
obtained as per prevailing rules for these pipes also and this benefit shall be
availed by the deptt.

14. All necessary permissions regarding road cutting, blasting, electrical line/pole
shifting, road diversion/closer, under ground utility services shifting/closer
disturbance, tree cutting etc. and all other permissions or licenses or permits
etc. Where ever applicable, such as from labour dept., mining dept., P& T
dept., Electricity board or company district administration, PWD, WRD,
Local Urban bodies etc. shall also be obtained by the contractor from the
competent authority at his own cost. The contractor shall be fully responsible
for any consequences for any lapse in this.

6
CHAPTER – I

CAST IRON PIPES AND SPECIALS WITH


SOCKET AND SPIGOT JOINTS
(LEAD JOINTS)

7
Chapter – I
CAST IRON PIPES AND SPECIALS WITH SOCKET
AND SPIGOT JOINTS (CLASS LA, A, B)
NOTES:
1. The C.I.pipe shall conform to IS -1536-1976
2. The C.I.fittings shall conform to IS -1538-1976 (Part I to XXIV).
3. The laying of C.I. pipes shall be done as per IS -3114:1985
4. The caulking lead shall conform to IS 782: 1978
5. All measurements shall be of the finished work.
6. Work shall be executed in accordance with the relevant Indian Standard
Specifications (Updated) and all the conditions of the agreement of the work.
7. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.

SOCKET & SPIGOT CAST IRON PIPES WITH LEAD JOINTS


(CLASS LA, A and B)
S.No. Items Unit Rates in Rs.
1.1 Providing, laying and jointing
following socket and spigot cast
iron (Spun) Pipes including Class LA Class A Class B
testing of joints, cost of pipes and
jointing materials etc. complete.
80mm Dia RM 1085.00 1179.00 1264.00
100mm Dia RM 1344.00 1480.00 1598.00
125mm Dia RM 1722.00 1879.00 2017.00
150mm Dia RM 2146.00 2352.00 2539.00
200mm Dia RM 3086.00 3348.00 3596.00
250mm Dia RM 4085.00 4448.00 4747.00
300mm Dia RM 5268.00 5759.00 6101.00
350mm Dia RM 6518.00 7070.00 7641.00
400mm Dia RM 7932.00 8668.00 9214.00
50mm Dia RM 9565.00 10508.00 11082.00
500mm Dia RM 11197.00 12198.00 12921.00
600mm Dia RM 14922.00 16291.00 17287.00
700mm Dia RM 18906.00 20656.00 22048.00
750mm Dia RM 20783.00 22721.00 24352.00
800mm Dia RM 29368.00 32293.00 35218.00
8
S.No. Items Unit Rates in Rs.
900mm Dia RM 35151.00 38678.00 42264.00
1000mm Dia RM 41451.00 45673.00 49718.00
1.2 Labour for laying in position
following socket & spigot cast Class LA Class A Class B
iron (Spun) pipes.
80mm Dia RM 18.00 20.00 21.00
100mm Dia RM 22.00 25.00 27.00
125mm Dia RM 29.00 32.00 34.00
150mm Dia RM 36.00 40.00 43.00
200mm Dia RM 53.00 58.00 62.00
250mm Dia RM 72.00 78.00 83.00
300mm Dia RM 92.00 101.00 107.00
350mm Dia RM 116.00 126.00 134.00
400mm Dia RM 142.00 155.00 165.00
450mm Dia RM 171.00 188.00 198.00
500mm Dia RM 200.00 218.00 231.00
600mm Dia RM 267.00 291.00 309.00
700mm Dia RM 344.00 376.00 401.00
750mm Dia RM 385.00 421.00 452.00
800mm Dia RM 545.00 599.00 653.00
900mm Dia RM 664.00 731.00 799.00
1000mm Dia RM 799.00 880.00 958.00
1.3 Providing lead caulked joints to
following socket & spigot cast
iron (spun) pipes and specials
class 'LA' 'A' and 'B' including
testing of the joints and cost of
jointing materials (i.e. pig lead
and spun yarn) etc. complete.
80mm Dia Each 179.00 179.00 179.00
100mm Dia Each 236.00 236.00 236.00
125mm Dia Each 258.00 258.00 258.00
150mm Dia Each 347.00 347.00 347.00
200mm Dia Each 521.00 521.00 521.00
250mm Dia Each 631.00 631.00 631.00
300mm Dia Each 786.00 786.00 786.00
350mm Dia Each 845.00 845.00 845.00
400mm Dia Each 999.00 999.00 999.00
450mm Dia Each 1327.00 1327.00 1327.00
500mm Dia Each 1531.00 1531.00 1531.00
600mm Dia Each 1722.00 1722.00 1722.00
700mm Dia Each 2022.00 2022.00 2022.00
750mm Dia Each 2367.00 2367.00 2367.00
800mm Dia Each 2992.00 2992.00 2992.00
900mm Dia Each 3635.00 3635.00 3635.00

9
S.No. Items Unit Rates in Rs.
1000mm Dia Each 4281.00 4281.00 4281.00
1.4 Labour for providing lead
caulked joints to following socket
& spigot cast iron (spun) pipes
and specials class 'LA' 'A' and 'B'
including testing of joints but
excluding cost of jointing
materials (i.e. pig lead and spun
yarn).
80mm Dia Each 125.00 125.00 125.00
100mm Dia Each 172.00 172.00 172.00
125mm Dia Each 180.00 180.00 180.00
150mm Dia Each 250.00 250.00 250.00
200mm Dia Each 353.00 353.00 353.00
250mm Dia Each 423.00 423.00 423.00
300mm Dia Each 533.00 533.00 533.00
350mm Dia Each 603.00 603.00 603.00
400mm Dia Each 654.00 654.00 654.00
450mm Dia Each 885.00 885.00 885.00
500mm Dia Each 1058.00 1058.00 1058.00
600mm Dia Each 1129.00 1129.00 1129.00
700mm Dia Each 1334.00 1334.00 1334.00
750mm Dia Each 1570.00 1570.00 1570.00
800mm Dia Each 2117.00 2117.00 2117.00
900mm Dia Each 2663.00 2663.00 2663.00
1000mm Dia Each 3210.00 3210.00 3210.00
1.5 Providing and laying in position Medium Heavy
following double socket cast iron Class Class
90° bend.
80mm Dia Each 1394.00 1597.00
100mm Dia Each 1975.00 2123.00
125mm Dia Each 2554.00 2786.00
150mm Dia Each 3391.00 3652.00
200mm Dia Each 5195.00 5652.00
250mm Dia Each 7303.00 8006.00
300mm Dia Each 9912.00 10861.00
350mm Dia Each 13261.00 14561.00
400mm Dia Each 16942.00 18637.00
450mm Dia Each 20990.00 23275.00
500mm Dia Each 26554.00 29373.00
600mm Dia Each 38027.00 42271.00
700mm Dia Each 52811.00 58799.00
750mm Dia Each 61569.00 68662.00
800mm Dia Each 72133.00 80436.00

10
S.No. Items Unit Rates in Rs.
900mm Dia Each 94857.00 106041.00
1000mm Dia Each 120928.00 135137.00
1.6 Providing and laying in position Medium Heavy
following double socket cast iron Class Class
45° bend.
80mm Dia Each 1394.00 1597.00
100mm Dia Each 1975.00 2123.00
125mm Dia Each 2485.00 2717.00
150mm Dia Each 3253.00 3514.00
200mm Dia Each 4851.00 5307.00
250mm Dia Each 6753.00 7386.00
300mm Dia Each 9086.00 9898.00
350mm Dia Each 11910.00 12997.00
400mm Dia Each 15022.00 16362.00
450mm Dia Each 18430.00 20288.00
500mm Dia Each 22928.00 25107.00
600mm Dia Each 32054.00 35302.00
700mm Dia Each 43637.00 48061.00
750mm Dia Each 50405.00 55649.00
800mm Dia Each 58764.00 64792.00
900mm Dia Each 75870.00 83855.00
1000mm Dia Each 95755.00 105840.00
1.7 Providing and laying in position Medium Heavy
following double socket cast iron Class Class
22½° bend.
80mm Dia Each 1188.00 1460.00
100mm Dia Each 1768.00 1917.00
125mm Dia Each 2210.00 2373.00
150mm Dia Each 2909.00 3101.00
200mm Dia Each 4369.00 4688.00
250mm Dia Each 5996.00 6423.00
300mm Dia Each 7848.00 8453.00
350mm Dia Each 10132.00 10934.00
400mm Dia Each 12675.00 13659.00
450mm Dia Each 15372.00 16662.00
500mm Dia Each 19017.00 20556.00
600mm Dia Each 26152.00 28405.00
700mm Dia Each 35175.00 38035.00
750mm Dia Each 40592.00 43916.00
800mm Dia Each 46818.00 50925.00
900mm Dia Each 59799.00 65082.00
11
S.No. Items Unit Rates in Rs.
1000mm Dia Each 74778.00 81378.00
1.8 Providing and laying in position Medium Heavy
following double socket cast iron Class Class
11¼° bend.
80mm Dia Each 1257.00 1391.00
100mm Dia Each 1631.00 1779.00
125mm Dia Each 2072.00 2235.00
150mm Dia Each 2703.00 2895.00
200mm Dia Each 4025.00 4344.00
250mm Dia Each 5514.00 5873.00
300mm Dia Each 7229.00 7696.00
350mm Dia Each 9208.00 9868.00
400mm Dia Each 11466.00 12237.00
450mm Dia Each 13808.00 14884.00
500mm Dia Each 17097.00 18351.00
600mm Dia Each 23165.00 24920.00
700mm Dia Each 30695.00 33057.00
750mm Dia Each 35330.00 38085.00
800mm Dia Each 40631.00 43957.00
900mm Dia Each 51764.00 55767.00
1000mm Dia Each 64254.00 69147.00
1.9 Providing and laying in position Medium Heavy
following all socket cast iron Tees Class Class
(all sizes in Milimeters) Body x
Branch Dia
80x80 Each 1855.00 1991.00
100x80 Each 2308.00 2346.00
100x100 Each 2450.00 2601.00
125x80 Each 2834.00 2914.00
125x100 Each 2976.00 3169.00
125x125 Each 3189.00 3425.00
150x80 Each 3345.00 3552.00
150x100 Each 3764.00 3808.00
150x125 Each 3905.00 4064.00
150x150 Each 4118.00 4455.00
200x80 Each 5331.00 5796.00
200x100 Each 5473.00 5938.00
200x125 Each 5615.00 6080.00
200x150 Each 5828.00 6293.00

12
S.No. Items Unit Rates in Rs.
200x200 Each 6325.00 6790.00
250x80 Each 7287.00 7934.00
250x100 Each 7429.00 8076.00
250x125 Each 7642.00 8288.00
250x150 Each 7854.00 8501.00
250x200 Each 8280.00 8927.00
250x250 Each 8777.00 9495.00
300x80 Each 9756.00 10656.00
300x100 Each 9827.00 10727.00
300x125 Each 10040.00 10940.00
300x150 Each 10182.00 11082.00
300x200 Each 10750.00 11650.00
300x250 Each 11247.00 12217.00
300x300 Each 11885.00 12856.00
350x200 Each 13380.00 14607.00
350x250 Each 13947.00 15174.00
350x300 Each 14586.00 15813.00
350x350 Each 15225.00 16523.00
400x200 Each 16699.00 18249.00
400x250 Each 17266.00 18817.00
400x300 Each 17834.00 19456.00
400x350 Each 18544.00 20166.00
400x400 Each 19396.00 21017.00
450x250 Each 21591.00 22199.00
450x300 Each 22230.00 23147.00
450x350 Each 22940.00 23975.00
450x400 Each 23650.00 24992.00
450x450 Each 24501.00 26570.00
500x250 Each 25726.00 26528.00
500x300 Each 26365.00 27476.00
500x350 Each 27075.00 28304.00
500x400 Each 27784.00 29392.00
500x450 Each 28636.00 30899.00
500x500 Each 29630.00 32373.00
600x300 Each 36538.00 38547.00
600x350 Each 37248.00 39375.00
600x400 Each 38099.00 40534.00
600x450 Each 38951.00 42112.00

13
S.No. Items Unit Rates in Rs.
600x500 Each 39874.00 43445.00
600x600 Each 42074.00 46169.00
700x350 Each 50655.00 53427.00
700x400 Each 51507.00 54657.00
700x450 Each 52429.00 56306.00
700x500 Each 53352.00 57639.00
700x600 Each 55268.00 59866.00
700x700 Each 57752.00 63091.00
750x400 Each 59256.00 62677.00
750x450 Each 60249.00 64326.00
750x500 Each 61243.00 65800.00
750x600 Each 63159.00 68099.00
750x700 Each 65359.00 70898.00
750x750 Each 66920.00 73220.00
800x400 Each 68594.00 71690.00
800x450 Each 69517.00 73339.00
800x500 Each 70511.00 74742.00
800x600 Each 72640.00 77254.00
800x700 Each 74840.00 80124.00
800x750 Each 75975.00 82020.00
800x800 Each 77679.00 85044.00
900x450 Each 89217.00 94062.00
900x500 Each 90211.00 95466.00
900x600 Each 92553.00 98332.00
900x700 Each 94966.00 101344.00
900x750 Each 96101.00 103241.00
900x800 Each 97379.00 105697.00
900x900 Each 100644.00 110389.00
1000x500 Each 113324.00 120021.00
1000x600 Each 115595.00 122746.00
1000x700 Each 118434.00 126326.00
1000x750 Each 119640.00 128293.00
1000x800 Each 120989.00 130820.00
1000x900 Each 123685.00 134803.00
1000x1000 Each
127518.00 139998.00

14
S.No. Items Unit Rates in Rs.
1.10 Providing and laying in position Medium Heavy
following all socketed cast iron Class Class
crosses (all sizes in millimeter).
80mm Each 2289.00 2423.00
100mm Each 2938.00 3156.00
125mm Each 3861.00 4093.00
150mm Each 4974.00 5303.00
200mm Each 7535.00 8060.00
250mm Each 10468.00 11240.00
300mm Each 14110.00 15127.00
1.11 Providing and laying in position Medium Heavy
following socket & spigot cast Class Class
iron tapers (Reducer) (all sizes in
mm).
100x80 Each 1457.00 1494.00
125x80 Each 1840.00 1849.00
125x100 Each 1911.00 2104.00
150x80 Each 2344.00 2609.00
150x100 Each 2415.00 2680.00
150x125 Each 2628.00 2715.00
200x100 Each 3486.00 3880.00
200x125 Each 3628.00 4022.00
200x150 Each 3841.00 4235.00
250x125 Each 4803.00 5237.00
250x150 Each 4945.00 5450.00
250x200 Each 5370.00 5946.00
300x150 Each 6563.00 7249.00
300x200 Each 7059.00 7817.00
300x250 Each 7556.00 8146.00
350x200 Each 8199.00 8422.00
350x250 Each 8767.00 9282.00
350x300 Each 9334.00 10301.00
400x250 Each 10950.00 11411.00
400x300 Each 11660.00 12501.00
400x350 Each 12369.00 13471.00
450x350 Each 14140.00 14820.00
450x400 Each 14991.00 16120.00
500x350 Each 16287.00 16665.00
500x400 Each 17139.00 17966.00

15
S.No. Items Unit Rates in Rs.
500x450 Each 18061.00 19686.00
600x400 Each 22273.00 23288.00
600x450 Each 23267.00 25080.00
600x500 Each 24331.00 26696.00
700x500 Each 29151.00 31309.00
700x600 Each 31564.00 34459.00
750x600 Each 35694.00 38362.00
750x700 Each 38603.00 42297.00
1.12 Providing and laying in position Medium Heavy
including testing following Class Class
Double Socket cast iron tapers
(reducer) (all sizes in mm)
100x80 Each 1457.00 1636.00
125x80 Each 1840.00 2275.00
125x100 Each 1911.00 2601.00
150x80 Each 2344.00 2893.00
150x100 Each 2415.00 3106.00
150x125 Each 2557.00 3212.00
200x100 Each 3486.00 4093.00
200x125 Each 3628.00 4377.00
200x150 Each 1855.00 4661.00
250x150 Each 4945.00 5663.00
250x200 Each 5370.00 6372.00
300x150 Each 6563.00 6895.00
300x200 Each 7059.00 7533.00
300x250 Each 7556.00 8005.00
350x200 Each 8199.00 9345.00
350x250 Each 8767.00 10559.00
350x300 Each 9334.00 11933.00
400x250 Each 10950.00 11837.00
400x300 Each 11660.00 13211.00
400x350 Each 12369.00 14536.00
450x350 Each 14140.00 15529.00
450x400 Each 14991.00 17114.00
500x350 Each 16287.00 17446.00
500x400 Each 17139.00 19101.00
500x450 Each 18061.00 20821.00
600x400 Each 22273.00 23998.00
600x450 Each 23267.00 24654.00
600x500 Each 24331.00 26625.00

16
S.No. Items Unit Rates in Rs.
700x500 Each 29151.00 30599.00
700x600 Each 31564.00 34459.00
750x600 Each 35694.00 36801.00
750x700 Each 38603.00 41091.00
1.13 Providing and laying in position Medium Heavy
following cast iron collars Class Class
80mm dia Each 1188.00 1322.00
100mm dia Each 1493.00 1642.00
125mm dia Each 1866.00 2029.00
150mm dia Each 2428.00 2620.00
200mm dia Each 3475.00 3794.00
250mm dia Each 4619.00 5047.00
300mm dia Each 5990.00 6457.00
350mm dia Each 7501.00 8090.00
400mm dia Each 8977.00 9819.00
450mm dia Each 11177.00 12111.00
500 mm dia Each 13257.00 14369.00
600 mm dia Each 17334.00 18805.00
700 mm dia Each 22376.00 24168.00
750 mm dia Each 25446.00 27489.00
800 mm dia Each 29254.00 31583.00
900 mm dia Each 36333.00 39127.00
1000mm dia Each 44201.00 47459.00
1.14 Providing and laying in position
following cast iron socket caps.

80mm dia Each 293.00 381.00


100mm dia Each 392.00 510.00
125mm dia Each 421.00 547.00
150mm dia Each 570.00 741.00
200mm dia Each 860.00 1032.00
250mm dia Each 1041.00 1250.00
300mm dia Each 1311.00 1573.00
350mm dia Each 1386.00 1663.00
400mm dia Each 1653.00 1984.00
450mm dia Each 2146.00 2360.00
500 mm dia Each 2519.00 2771.00
600 mm dia Each 2756.00 3032.00
700 mm dia Each 3247.00 3572.00
750 mm dia Each 3828.00 4211.00
800 mm dia Each 5005.00 5406.00
900 mm dia Each 6182.00 6677.00
1000 mm dia Each 7366.00 7955.00

17
S.No. Items Unit Rates in Rs.
1.15 Providing and laying in position Medium Heavy
following cast iron plugs. Class Class
80mm dia Each 431.00 565.00
100mm dia Each 599.00 747.00
125mm dia Each 765.00 928.00
150mm dia Each 1120.00 1312.00
200mm dia Each 1755.00 2005.00
250mm dia Each 2418.00 2776.00
300mm dia Each 3238.00 3636.00
350mm dia Each 4088.00 4606.00
400mm dia Each 5280.00 5837.00
450mm dia Each 6768.00 7560.00
500 mm dia Each 8279.00 9178.00
600 mm dia Each 11290.00 12476.00
700 mm dia Each 15407.00 16844.00
750 mm dia Each 18121.00 19738.00
800 mm dia Each 21716.00 23477.00
900 mm dia Each 28013.00 30096.00
1000 mm dia Each 35383.00 37788.00
1.16 Providing and laying in position Medium Heavy
following sizes of socket & spigot Class Class
or all socketed cast iron specials
class MEDIUM or HEAVY which
does not appear in above items
of schedule.
80mm to 300mm Dia Kg 87.00 87.00
Above 300mm Dia Kg 84.00 84.00
1.17 Labour for laying in position Medium Heavy
following double socket cast iron Class Class
45° bends.
80mm dia Each 34.00 38.00
100mm dia Each 49.00 51.00
125mm dia Each 63.00 68.00
150mm dia Each 82.00 87.00
200mm dia Each 122.00 131.00
250mm dia Each 175.00 188.00
300mm dia Each 238.00 255.00
350mm dia Each 312.00 335.00
400mm dia Each 397.00 426.00
450mm dia Each 483.00 523.00
500 mm dia Each 606.00 654.00
600 mm dia Each 869.00 945.00

18
S.No. Items Unit Rates in Rs.
700 mm dia Each 1198.00 1306.00
750 mm dia Each 1382.00 1511.00
800 mm dia Each 1595.00 1745.00
900 mm dia Each 2068.00 2272.00
1000mm dia Each 2623.00 2886.00
1.18 Labour for laying in position Medium Heavy
following double socket cast Iron Class Class
900 bends
80mm dia Each 34.00 38.00
100mm dia Each 49.00 51.00
125mm dia Each 65.00 70.00
150mm dia Each 87.00 91.00
200mm dia Each 133.00 141.00
250mm dia Each 192.00 207.00
300mm dia Each 264.00 285.00
350mm dia Each 352.00 382.00
400mm dia Each 454.00 494.00
450mm dia Each 559.00 612.00
500 mm dia Each 713.00 781.00
600 mm dia Each 1047.00 1152.00
700 mm dia Each 1471.00 1625.00
750 mm dia Each 1713.00 1897.00
800 mm dia Each 1992.00 2209.00
900 mm dia Each 2631.00 2931.00
1000mm dia Each 3370.00 3756.00
1.19 Labour for laying in position Medium Heavy
following double socket cast Class Class
iron 22½°. bends.
80mm dia Each 27.00 34.00
100mm dia Each 42.00 44.00
125mm dia Each 55.00 57.00
150mm dia Each 72.00 74.00
200mm dia Each 108.00 112.00
250mm dia Each 152.00 158.00
300mm dia Each 200.00 211.00
350mm dia Each 260.00 274.00
400mm dia Each 327.00 346.00
450mm dia Each 392.00 416.00
500 mm dia Each 490.00 519.00
600 mm dia Each 694.00 741.00
700 mm dia Each 947.00 1009.00
750 mm dia Each 1091.00 1163.00
800 mm dia Each 1241.00 1334.00

19
S.No. Items Unit Rates in Rs.
900 mm dia Each 1591.00 1715.00
1000mm dia Each 2000.00 2161.00
1.20 Labour for laying in position Medium Heavy
following double socket castiron Class Class
11¼ ° bends.
80mm dia Each 30.00 32.00
100mm dia Each 38.00 40.00
125mm dia Each 51.00 53.00
150mm dia Each 65.00 68.00
200mm dia Each 97.00 101.00
250mm dia Each 137.00 141.00
300mm dia Each 181.00 188.00
350mm dia Each 232.00 243.00
400mm dia Each 291.00 304.00
450mm dia Each 346.00 363.00
500 mm dia Each 433.00 454.00
600 mm dia Each 606.00 637.00
700 mm dia Each 814.00 861.00
750 mm dia Each 935.00 990.00
800 mm dia Each 1057.00 1127.00
900 mm dia Each 1353.00 1439.00
1000mm dia Each 1688.00 1798.00
1.21 Labour for laying in position Medium Heavy
including testing following all Class Class
socket cast iron, tees (all Sizes in
mm)
80x80 Each 46.00 49.00
100x80 Each 57.00 59.00
100x100 Each 61.00 63.00
125x80 Each 72.00 76.00
125x100 Each 76.00 80.00
125x125 Each 82.00 87.00
150x80 Each 91.00 95.00
150x100 Each 95.00 99.00
150x125 Each 99.00 106.00
150x150 Each 106.00 112.00
200x80 Each 133.00 141.00
200x100 Each 137.00 146.00
200x125 Each 141.00 150.00
200x150 Each 148.00 156.00
200x200 Each 162.00 171.00
250x80 Each 186.00 198.00
250x100 Each 190.00 203.00

20
S.No. Items Unit Rates in Rs.
250x125 Each 196.00 209.00
250x150 Each 203.00 215.00
250x200 Each 215.00 228.00
250x250 Each 230.00 245.00
300x80 Each 251.00 270.00
300x100 Each 253.00 272.00
300x125 Each 260.00 279.00
300x150 Each 264.00 283.00
300x200 Each 281.00 300.00
300x250 Each 295.00 317.00
300x300 Each 314.00 335.00
350x200 Each 357.00 384.00
350x250 Each 373.00 401.00
350x300 Each 392.00 420.00
350x350 Each 411.00 441.00
400x200 Each 447.00 483.00
400x250 Each 464.00 500.00
400x300 Each 481.00 519.00
400x350 Each 502.00 540.00
400x400 Each 528.00 565.00
450x250 Each 578.00 622.00
450x300 Each 597.00 641.00
450x350 Each 618.00 663.00
450x400 Each 639.00 684.00
450x450 Each 665.00 711.00
500x250 Each 690.00 751.00
500x300 Each 709.00 770.00
500x350 Each 730.00 791.00
500x400 Each 751.00 814.00
500x450 Each 776.00 840.00
500x500 Each 806.00 871.00
600x300 Each 1004.00 1099.00
600x350 Each 1025.00 1120.00
600x400 Each 1051.00 1146.00
600x450 Each 1076.00 1173.00
600x500 Each 1104.00 1201.00
600x600 Each 1169.00 1270.00

21
S.No. Items Unit Rates in Rs.
700x350 Each 1409.00 1538.00
700x400 Each 1435.00 1566.00
700x450 Each 1462.00 1595.00
700x500 Each 1490.00 1623.00
700x600 Each 1547.00 1677.00
700x700 Each 1620.00 1756.00
750x400 Each 1648.00 1804.00
750x450 Each 1677.00 1834.00
750x500 Each 1707.00 1865.00
750x600 Each 1764.00 1922.00
750x700 Each 1829.00 1988.00
750x750 Each 1876.00 2036.00
800x400 Each 1891.00 2072.00
800x450 Each 1918.00 2102.00
800x500 Each 1948.00 2131.00
800x600 Each 2011.00 2194.00
800x700 Each 2076.00 2262.00
800x750 Each 2110.00 2298.00
800x800 Each 2161.00 2351.00
900x450 Each 2469.00 2718.00
900x500 Each 2498.00 2747.00
900x600 Each 2568.00 2821.00
900x700 Each 2640.00 2893.00
900x750 Each 2673.00 2929.00
900x800 Each 2711.00 2965.00
900x900 Each 2808.00 3066.00
1000x500 Each 3150.00 3477.00
1000x600 Each 3218.00 3547.00
1000x700 Each 3302.00 3636.00
1000x750 Each 3338.00 3674.00
1000x800 Each 3378.00 3711.00
1000x900 Each 3458.00 3792.00
1000x1000 Each 3572.00 3908.00
1.22 Labour for laying in position Medium Heavy
following all socket cast iron Class Class
crosses. (all sizes in mm)
80mm dia Each 61.00 63.00

22
S.No. Items Unit Rates in Rs.
100mm dia Each 78.00 82.00
125mm dia Each 106.00 110.00
150mm dia Each 135.00 141.00
200mm dia Each 205.00 215.00
250mm dia Each 289.00 306.00
300mm dia Each 392.00 416.00
1.23 Labour for laying in position Medium Heavy
including testing following Class Class
socket and spigot cast iron
tapers, (reducer) (all Sizes in
mm)
100x80 Each 32.00 34.00
125x80 Each 42.00 44.00
125x100 Each 44.00 49.00
150x80 Each 53.00 57.00
150x100 Each 55.00 59.00
150x125 Each 61.00 65.00
200x100 Each 78.00 84.00
200x125 Each 82.00 89.00
200x150 Each 89.00 95.00
250x125 Each 112.00 118.00
250x150 Each 116.00 124.00
250x200 Each 129.00 139.00
300x150 Each 156.00 169.00
300x200 Each 171.00 186.00
300x250 Each 186.00 205.00
350x200 Each 203.00 219.00
350x250 Each 219.00 238.00
350x300 Each 236.00 260.00
400x250 Each 276.00 302.00
400x300 Each 298.00 325.00
400x350 Each 319.00 350.00
450x350 Each 357.00 390.00
450x400 Each 382.00 420.00
500x350 Each 409.00 445.00
500x400 Each 435.00 475.00
500x450 Each 462.00 506.00
600x400 Each 580.00 633.00
600x450 Each 610.00 667.00
600x500 Each 641.00 703.00

23
S.No. Items Unit Rates in Rs.
700x500 Each 770.00 840.00
700x600 Each 842.00 922.00
750x600 Each 947.00 1038.00
750x700 Each 1034.00 1137.00
1.24 Labour for laying in position Medium Heavy
including testing following Class Class
Double Socket cast iron taper
(reducer (all sizes in mm)
100x80 Each 32.00 38.00
125x80 Each 42.00 57.00
125x100 Each 44.00 63.00
150x80 Each 53.00 65.00
150x100 Each 55.00 72.00
150x125 Each 59.00 80.00
200x100 Each 78.00 91.00
200x125 Each 82.00 99.00
200x150 Each 89.00 108.00
250x150 Each 116.00 131.00
250x200 Each 129.00 152.00
300x150 Each 156.00 158.00
300x200 Each 171.00 177.00
300x250 Each 186.00 200.00
350x200 Each 203.00 247.00
350x250 Each 219.00 276.00
350x300 Each 236.00 308.00
400x250 Each 276.00 314.00
400x300 Each 298.00 346.00
400x350 Each 319.00 382.00
450x350 Each 357.00 411.00
450x400 Each 382.00 449.00
500x350 Each 409.00 468.00
500x400 Each 435.00 509.00
500x450 Each 462.00 540.00
600x400 Each 580.00 654.00
600x450 Each 610.00 654.00
600x500 Each 641.00 701.00
700x500 Each 770.00 819.00
700x600 Each 842.00 922.00
750x600 Each 947.00 992.00
750x700 Each 1034.00 1101.00

24
S.No. Items Unit Rates in Rs.
1.25 Labour for laying in position Medium Heavy
including testing following cast Class Class
Iron Collars
80 mm Dia Each 27.00 30.00
100 mm Dia Each 34.00 36.00
125 mm Dia Each 44.00 46.00
150 mm Dia Each 57.00 59.00
200 mm Dia Each 80.00 84.00
250 mm Dia Each 110.00 116.00
300 mm Dia Each 143.00 150.00
350 mm Dia Each 181.00 190.00
400 mm Dia Each 217.00 232.00
450 mm Dia Each 268.00 281.00
500 mm Dia Each 319.00 335.00
600 mm Dia Each 433.00 456.00
700 mm Dia Each 568.00 597.00
750 mm Dia Each 641.00 675.00
800 mm Dia Each 720.00 760.00
900 mm Dia Each 895.00 945.00
1000 mm Dia Each 1093.00 1154.00
1.26 Labour for laying in position Medium Heavy
following socketed cast iron caps. Class Class
80 mm Dia Each 10.00 15.00
100 mm Dia Each 13.00 19.00
125 mm Dia Each 18.00 25.00
150 mm Dia Each 22.00 32.00
200 mm Dia Each 35.00 51.00
250 mm Dia Each 50.00 72.00
300 mm Dia Each 68.00 97.00
350 mm Dia Each 90.00 129.00
400 mm Dia Each 114.00 162.00
450 mm Dia Each 143.00 205.00
500 mm Dia Each 174.00 249.00
600 mm Dia Each 253.00 361.00
700 mm Dia Each 347.00 496.00
750 mm Dia Each 402.00 574.00
800 mm Dia Each 464.00 663.00
900 mm Dia Each 598.00 855.00
1000 mm Dia Each 759.00 1085.00

25
S.No. Items Unit Rates in Rs.
1.27 Labour for laying in position Medium Heavy
including testing following cast Class Class
iron plugs.
80 mm Dia Each 4.00 6.00
100 mm Dia Each 6.00 8.00
125 mm Dia Each 11.00 13.00
150 mm Dia Each 17.00 19.00
200 mm Dia Each 27.00 30.00
250 mm Dia Each 42.00 46.00
300 mm Dia Each 59.00 63.00
350 mm Dia Each 80.00 87.00
400 mm Dia Each 108.00 114.00
450 mm Dia Each 137.00 146.00
500 mm Dia Each 171.00 181.00
600 mm Dia Each 253.00 268.00
700 mm Dia Each 361.00 380.00
750 mm Dia Each 424.00 445.00
800 mm Dia Each 496.00 519.00
900 mm Dia Each 648.00 677.00
1000 mm Dia Each 831.00 867.00
1.28 Labour for laying in position Medium Heavy
following sizes of socket & spigot Class Class
or all socketed cast iron standard
specials class ‘MEDIUM’ or
‘HEAVY’ Which do not
appear in above items of the
schedule.
80 mm to 750 mm Dia Kg 2.00 2.00

26
CHAPTER – II

CAST IRON TYTON PIPES


WITH TYTON JOINTS

27
Chapter – II
CAST IRON TYTON PIPES WITH TYTON JOINTS (CLASS LA, A, B)

NOTES:
1. The C.I. pipe shall conform to IS -1536-1976
2. The C.I. fittings shall conform to IS -1538-1976 (Part I to XXIV).
3. The laying of C.I. pipes shall be done as per IS -3114:1985
4. The caulking lead shall conform to IS 782: 1978
5. All measurements shall be of the finished work.
6. Work shall be executed in accordance with the relevant Indian Standard
Specifications (Updated) and all the conditions of the agreement of the work.
7. The rubber sealing rings for jointing of pipe line shall be conforming to IS
5382: 1985
8. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

SOCKET AND SPIGOT CAST IRON PIPES WITH TYTON JOINTS


(CLASS LA, A, AND B)

S.No. Items Unit Rates in Rs.


2.1 Providing, laying and jointing
following cast iron tyton pipes with
tyton joints including testing of
joints, cost of pipes and jointing
materials etc complete.
Class LA Class A Class B
80mm Dia Meter 1177.00 1205.00 1293.00
100mm Dia Meter 1448.00 1513.00 1634.00
125mm Dia Meter 1839.00 1921.00 2063.00
150mm Dia Meter 2281.00 2405.00 2596.00
200mm Dia Meter 3302.00 3424.00 3678.00
250mm Dia Meter 4347.00 4550.00 4857.00
300mm Dia Meter 5603.00 5891.00 6243.00
350mm Dia Meter 6907.00 7235.00 7251.00
400mm Dia Meter 8554.00 8869.00 9431.00
450mm Dia Meter 10283.00 10750.00 11345.00
500mm Dia Meter 11942.00 12481.00 13226.00
600mm Dia Meter 15853.00 16668.00 17695.00
700mm Dia Meter 20185.00 21139.00 22572.00
750mm Dia Meter 22186.00 23258.00 24935.00
800mm Dia Meter 30914.00 33053.00 36051.00
900mm Dia Meter 37003.00 39598.00 43275.00

28
S.No. Items Unit Rates in Rs.
1000mm Dia Meter 43575.00 46771.00 50923.00
2.2 Labour for laying in position Class LA Class- A Class-B
including testing following cast iron
tyton pipes.
80mm Dia Meter 18.00 20.00 21.00
100mm Dia Meter 22.00 25.00 27.00
125mm Dia Meter 29.00 32.00 34.00
150mm Dia Meter 36.00 40.00 43.00
200mm Dia Meter 53.00 58.00 62.00
250mm Dia Meter 72.00 78.00 83.00
300mm Dia Meter 92.00 101.00 107.00
350mm Dia Meter 116.00 126.00 134.00
400mm Dia Meter 142.00 155.00 165.00
450mm Dia Meter 171.00 188.00 198.00
500mm Dia Meter 200.00 218.00 231.00
600mm Dia Meter 267.00 291.00 309.00
700mm Dia Meter 344.00 376.00 401.00
750mm Dia Meter 385.00 421.00 452.00
800mm Dia Meter 545.00 599.00 653.00
900mm Dia Meter 664.00 731.00 799.00
1000mm Dia Meter 799.00 880.00 958.00
2.3 Providing tyton joints to following
tyton pipes of class 'LA' 'A' and 'B'
including testing of joints and cost
of jointing materials (i.e. Rubber
Gasket and Soap solution etc.).
80mm Dia Each 83.00
100mm Dia Each 92.00
125mm Dia Each 103.00
150mm Dia Each 117.00
200mm Dia Each 191.00
250mm Dia Each 228.00
300mm Dia Each 292.00
350mm Dia Each 335.00
400mm Dia Each 556.00
450mm Dia Each 640.00
500mm Dia Each 652.00
600mm Dia Each 808.00
700mm Dia Each 1123.00
750mm Dia Each 1233.00
800mm Dia Each 1306.00
900mm Dia Each 1566.00
1000mm Dia Each 1788.00

29
S.No. Items Unit Rates in Rs.
2.4 Labour for providing tyton joints to
following tyton pipes class 'LA' 'A'
and 'B' including testing of joints
but excluding cost of Rubber
Gasket.
80mm Dia Each 55.00
100mm Dia Each 58.00
125mm Dia Each 61.00
150mm Dia Each 65.00
200mm Dia Each 68.00
250mm Dia Each 82.00
300mm Dia Each 88.00
350mm Dia Each 102.00
400mm Dia Each 132.00
450mm Dia Each 146.00
500mm Dia Each 156.00
600mm Dia Each 190.00
700mm Dia Each 222.00
750mm Dia Each 232.00
800mm Dia Each 246.00
900mm Dia Each 289.00
1000mm Dia Each 310.00

30
CHAPTER – III

CAST IRON PIPES AND SPECIALS WITH


FLANGED JOINTS

31
Chapter – III
CAST IRON PIPES AND SPECIALS WITH FLANGED JOINTS

NOTES:
1. The Horizontal C.I. double flanged pipe shall conform to IS -7181-1986
2. The C.I. fittings shall conform to IS -1538-1976 (Part I to XXIV).
3. The laying of C.I. pipes shall be done as per IS -3114:1985
4. All measurements shall be of the finished work.
5. Work shall be executed in accordance with the relevant Indian Standard
Specifications (Updated) and all the conditions of the agreement of the work.
6. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

CAST IRON PIPES AND SPECIALS WITH FLANGED JOINTS (CLASS A, B)

S.No. ITEMS Unit Rates in Rs.


3.1 Providing, fixing and testing
following double flanged cast iron
(horizontal cast) pipe per IS : 7181
of One Meter length.
80mm Dia Each 1673.00
100mm Dia Each 2140.00
125mm Dia Each 2607.00
150mm Dia Each 3216.00
200mm Dia Each 4374.00
250mm Dia Each 5841.00
300mm Dia Each 7368.00
350mm Dia Each 9136.00
400mm Dia Each 11414.00
450mm Dia Each 13828.00
500mm Dia Each 15990.00
600mm Dia Each 21160.00
700mm Dia Each 27042.00
750mm Dia Each 29447.00
3.2 Labour only for fixing including
testing following double flanged
cast iron (horizontal cast) pipe per
IS : 7181 of One Meter length.
80mm Dia Each 128.00
100mm Dia Each 139.00
125mm Dia Each 152.00
150mm Dia Each 166.00

32
S.No. ITEMS Unit Rates in Rs.
200mm Dia Each 189.00
250mm Dia Each 236.00
300mm Dia Each 269.00
350mm Dia Each 321.00
400mm Dia Each 406.00
450mm Dia Each 463.00
500mm Dia Each 513.00
600mm Dia Each 646.00
700mm Dia Each 788.00
750mm Dia Each 850.00
3.3 Providing, fixing including testing
following double flanged cast iron
(horizontal cast) pipe per IS : 7181
of Two Meter length.
80mm Dia Each 3036.00
100mm Dia Each 3850.00
125mm Dia Each 4779.00
150mm Dia Each 5934.00
200mm Dia Each 8244.00
250mm Dia Each 10982.00
300mm Dia Each 14024.00
350mm Dia Each 17308.00
400mm Dia Each 21431.00
450mm Dia Each 25970.00
500mm Dia Each 30087.00
600mm Dia Each 39986.00
700mm Dia Each 50911.00
750mm Dia Each 55701.00
3.4 Labour only for fixing including
testing following double flanged
cast iron (horizontal cast) pipe per
IS : 7181 of Two Meter length.
80mm Dia Each 146.00
100mm Dia Each 161.00
125mm Dia Each 181.00
150mm Dia Each 202.00
200mm Dia Each 242.00
250mm Dia Each 307.00
300mm Dia Each 361.00
350mm Dia Each 438.00
400mm Dia Each 548.00
450mm Dia Each 634.00
500mm Dia Each 713.00
600mm Dia Each 913.00
700mm Dia Each 1132.00

33
S.No. ITEMS Unit Rates in Rs.
750mm Dia Each 1235.00
3.5 Providing, fixing including testing
following double flanged cast iron
(horizontal cast) pipe per IS : 7181
of 2.75 M length.
80mm Dia Each 4045.00
100mm Dia Each 5116.00
125mm Dia Each 6386.00
150mm Dia Each 7945.00
200mm Dia Each 11106.00
250mm Dia Each 14784.00
300mm Dia Each 18946.00
350mm Dia Each 23349.00
400mm Dia Each 28838.00
450mm Dia Each 34948.00
500mm Dia Each 40509.00
600mm Dia Each 53905.00
700mm Dia Each 68554.00
750mm Dia Each 75102.00
3.6 Labour only for fixing including
testing following double flanged
cast iron (horizontal cast) pipe per
IS : 7181 of 2.75 Meter length.
80mm Dia Each 146.00
100mm Dia Each 161.00
125mm Dia Each 181.00
150mm Dia Each 202.00
200mm Dia Each 242.00
250mm Dia Each 307.00
300mm Dia Each 361.00
350mm Dia Each 438.00
400mm Dia Each 548.00
450mm Dia Each 634.00
500mm Dia Each 713.00
600mm Dia Each 913.00
700mm Dia Each 1132.00
750mm Dia Each 1235.00
3.7 Providing flanged joints to
following double flanged cast iron
(horizontal cast) pipes and specials
class 'A' and 'B' including labour&
cost of jointing materials (i.e. Bolt,
Nuts and Rubber insertions)
including testing of joint etc.
complete

34
S.No. ITEMS Unit Rates in Rs.
80mm Dia Each 155.00
100mm Dia Each 214.00
125mm Dia Each 218.00
150mm Dia Each 249.00
200mm Dia Each 252.00
250mm Dia Each 350.00
300mm Dia Each 356.00
350mm Dia Each 482.00
400mm Dia Each 699.00
450mm Dia Each 843.00
500mm Dia Each 947.00
600mm Dia Each 1167.00
700mm Dia Each 1587.00
750mm Dia Each 1597.00
800mm Dia Each 1757.00
900mm Dia Each 2104.00
1000mm Dia Each 2475.00
3.8 Labour for Providing Flanged
joint to following flanged cast iron
pipes and specials class 'A' and 'B'
including testing of joints but
excluding cost of jointing materials
(i.e. Bolts & Nut, Rubber insertion)
80mm Dia Each 55.00
100mm Dia Each 58.00
125mm Dia Each 61.00
150mm Dia Each 65.00
200mm Dia Each 68.00
250mm Dia Each 82.00
300mm Dia Each 88.00
350mm Dia Each 102.00
400mm Dia Each 132.00
450mm Dia Each 146.00
500mm Dia Each 156.00
600mm Dia Each 190.00
700mm Dia Each 222.00
750mm Dia Each 232.00
800mm Dia Each 246.00
900mm Dia Each 289.00
1000mm Dia Each 310.00

35
S.No. ITEMS Unit Rates in Rs.
3.9 Labour only for providing flanged
joints to following double flanged
horizontally cast iron pipes and
specials in vertical or inclined
direction including testing of joints
but excluding cost or jointing
materials (i.e. bolts, nuts and
rubber insertion sheet)
80mm to 750mm dia 200% above the rates provided vide
in truly vertical position item No.3.2, 3.4 & 3.6
In inclined position at inclination 100% above rates provided vide item
45% & above No. 3.2, 3.4 & 3.6
In inclined position at inclination less Same as rates provided vide item no.
than 45% 3.2, 3.4 & 3.6
3.10 Providing & Laying in position
including testing following cast
iron flanged sockets (all sizes in
mm) confirming to IS 1538 Medium Class Heavy Class
80mm Dia Each 862.00 933.00
100mm Dia Each 1077.00 1149.00
125mm Dia Each 1364.00 1436.00
150mm Dia Each 1795.00 1867.00
200mm Dia Each 2585.00 2657.00
250mm Dia Each 4164.00 4452.00
300mm Dia Each 5313.00 5672.00
350mm Dia Each 6749.00 7180.00
400mm Dia Each 8329.00 8831.00
450mm Dia Each 9621.00 10196.00
500mm Dia Each 11703.00 12421.00
600mm Dia Each 15868.00 16801.00
700mm Dia Each 20750.00 21971.00
750mm Dia Each 23550.00 24915.00
800mm Dia Each 26536.00 28074.00
900mm Dia Each 32304.00 34177.00
1000mm Dia Each 39362.00 41645.00
3.11 Providing and laying in position
including testing following cast
iron flanged spigot (tail piece)
80mm Dia Each 790.00 862.00
100mm Dia Each 933.00 1005.00
125mm Dia Each 1221.00 1364.00
150mm Dia Each 1508.00 1651.00
200mm Dia Each 2513.00 2800.00
250mm Dia Each 3375.00 3805.00
300mm Dia Each 4308.00 4882.00

36
S.No. ITEMS Unit Rates in Rs.
350mm Dia Each 5457.00 6103.00
400mm Dia Each 6606.00 7467.00
450mm Dia Each 7826.00 8831.00
500mm Dia Each 9334.00 10483.00
600mm Dia Each 14432.00 16299.00
700mm Dia Each 18740.00 21181.00
750mm Dia Each 21253.00 23981.00
800mm Dia Each 23689.00 23992.00
900mm Dia Each 28448.00 34136.00
1000mm Dia Each 34187.00 39130.00
3.12 Providing and laying in position
including testing following cast
iron double flanged 90° bends (all
sizes in mm) Medium Class Heavy Class
80mm Dia Each 862.00 933.00
100mm Dia Each 1149.00 1651.00
125mm Dia Each 1508.00 2226.00
150mm Dia Each 2082.00 3518.00
200mm Dia Each 3231.00 5170.00
250mm Dia Each 4667.00 7180.00
300mm Dia Each 6462.00 9837.00
350mm Dia Each 8831.00 12996.00
400mm Dia Each 11632.00 16227.00
450mm Dia Each 18524.00 20822.00
500mm Dia Each 28146.00 31736.00
600mm Dia Each 40639.00 45880.00
700mm Dia Each 47962.00 54209.00
750mm Dia Each 56606.00 64054.00
800mm Dia Each 66691.00 75507.00
900mm Dia Each 87876.00 100028.00
1000mm Dia Each 115332.00 130993.00
3.13 Providing and laying in position
including testing following cast iron
double flanged 45° bends (all sizes
in mm)
80mm Dia Each 949.00 1005.00
100mm Dia Each 1220.00 1292.00
125mm Dia Each 1694.00 1795.00
150mm Dia Each 2304.00 2441.00
200mm Dia Each 3659.00 3877.00
250mm Dia Each 5420.00 5744.00
300mm Dia Each 7589.00 8042.00
350mm Dia Each 7792.00 8257.00
400mm Dia Each 10096.00 10698.00
450mm Dia Each 12535.00 13283.00

37
S.No. ITEMS Unit Rates in Rs.
500mm Dia Each 15652.00 16586.00
600mm Dia Each 23173.00 24556.00
700mm Dia Each 32862.00 34823.00
750mm Dia Each 38756.00 41070.00
3.14 Providing and laying in position Medium Class Heavy Class
including testing following cast iron
double flanged 90° Duck Foot Bend
80mm Dia Each 1436.00 1508.00
100mm Dia Each 1795.00 1867.00
125mm Dia Each 2441.00 2585.00
150mm Dia Each 3231.00 3375.00
200mm Dia Each 5026.00 5313.00
250mm Dia Each 7467.00 7970.00
300mm Dia Each 10483.00 11201.00
350mm Dia Each 14360.00 15365.00
400mm Dia Each 18812.00 20176.00
450mm Dia Each 23335.00 25130.00
500mm Dia Each 29725.00 32023.00
600mm Dia Each 45019.00 48609.00
3.15 Providing and laying in position Medium Class Heavy Class
including testing following cast
iron all flanged Tees (all sizes in
mm) Body x Branch

80x80 Each 1436.00 1508.00


100x80 Each 1651.00 1795.00
100x100 Each 1723.00 1867.00
125x80 Each 2082.00 2298.00
125x100 Each 2298.00 2441.00
125x125 Each 2369.00 2585.00
150x80 Each 2728.00 2944.00
150x100 Each 2800.00 3016.00
150x125 Each 2944.00 3231.00
150x150 Each 3087.00 3375.00
200x80 Each 4021.00 4452.00
200x100 Each 4093.00 4523.00
200x125 Each 4308.00 4739.00
200x150 Each 4452.00 4882.00
200x200 Each 4811.00 5313.00
250x80 Each 5744.00 6390.00
250x100 Each 5816.00 6462.00
250x125 Each 6031.00 6677.00
250x150 Each 6247.00 6893.00
250x200 Each 6606.00 7324.00
250x250 Each 7108.00 7826.00

38
S.No. ITEMS Unit Rates in Rs.
300x80 Each 7826.00 8760.00
300x100 Each 7970.00 8903.00
300x125 Each 8113.00 9047.00
300x150 Each 8329.00 9262.00
300x200 Each 8760.00 9765.00
300x250 Each 9262.00 10267.00
300x300 Each 9765.00 10842.00
350x200 Each 10914.00 12134.00
350x250 Each 11201.00 12421.00
350x300 Each 12206.00 13498.00
350x350 Each 12565.00 14001.00
400x200 Each 13570.00 15150.00
400x250 Each 13857.00 15437.00
400x300 Each 14934.00 16658.00
400x350 Each 15365.00 17160.00
400x400 Each 15868.00 17663.00
450x250 Each 16658.00 18668.00
450x300 Each 17735.00 19889.00
450x350 Each 18165.00 20391.00
450x400 Each 18596.00 20822.00
450x450 Each 19027.00 21253.00
500x250 Each 20176.00 22617.00
500x300 Each 21396.00 23981.00
500x350 Each 21899.00 24556.00
500x400 Each 22402.00 25058.00
500x450 Each 22832.00 25561.00
500x500 Each 23335.00 26063.00
600x300 Each 29725.00 33459.00
600x350 Each 30443.00 34105.00
600x400 Each 31018.00 34823.00
600x450 Each 31448.00 35326.00
600x500 Each 31951.00 35828.00
600x600 Each 33100.00 37049.00
700x350 Each 40926.00 46096.00
700x400 Each 41500.00 46742.00
700x450 Each 42147.00 47388.00
700x500 Each 42721.00 48034.00
700x600 Each 43870.00 49255.00
700x700 Each 45378.00 50763.00
750x400 Each 47532.00 53563.00
750x450 Each 48106.00 54137.00
750x500 Each 48896.00 54999.00
750x600 Each 49829.00 55932.00
750x700 Each 50763.00 56866.00
800x400 Each 54712.00 61604.00

39
S.No. ITEMS Unit Rates in Rs.
800x450 Each 55286.00 62251.00
800x500 Each 55932.00 62969.00
800x600 Each 57296.00 64405.00
800x700 Each 58661.00 65769.00
800x750 Each 59450.00 66630.00
800x800 Each 60384.00 67564.00
900x450 Each 69359.00 78334.00
900x500 Each 70364.00 79411.00
900x600 Each 71800.00 80990.00
900x700 Each 73236.00 82498.00
900x750 Each 74098.00 83360.00
900x800 Each 74959.00 84221.00
900x900 Each 76180.00 85442.00
3.16 Providing and laying in position Medium Class Heavy Class
including testing following cast
iron double flanged Tapers (all size
in mm) Body x Branch

100x80 Each 790.00 862.00


125x80 Each 1292.00 1436.00
125x100 Each 1436.00 1580.00
150x80 Each 1508.00 1651.00
150x100 Each 1651.00 1795.00
150x125 Each 1795.00 1939.00
200x100 Each 2082.00 2226.00
200x125 Each 2226.00 2441.00
200x150 Each 2441.00 2657.00
250x125 Each 2728.00 2944.00
250x150 Each 2872.00 3159.00
250x200 Each 3303.00 3590.00
300x150 Each 3375.00 3662.00
300x200 Each 3805.00 4164.00
300x250 Each 4308.00 4667.00
350x200 Each 5672.00 6247.00
350x250 Each 6247.00 6893.00
350x300 Each 6893.00 7611.00
400x250 Each 7036.00 7826.00
400x300 Each 7754.00 8616.00
400x350 Each 8544.00 9478.00
450x300 Each 8401.00 9334.00
450x350 Each 9406.00 10411.00
450x400 Each 10267.00 11344.00
500x350 Each 10339.00 11488.00
500x400 Each 11273.00 12493.00
500x450 Each 12062.00 13355.00
40
S.No. ITEMS Unit Rates in Rs.
600x400 Each 13642.00 15078.00
600x450 Each 14360.00 15940.00
600x500 Each 15509.00 17160.00
700x500 Each 18237.00 20176.00
700x600 Each 20607.00 22761.00
750x600 Each 21971.00 24268.00
750x700 Each 23981.00 26422.00
800x600 Each 24699.00 27284.00
800x700 Each 26710.00 29438.00
800x750 Each 27858.00 30730.00
900x700 Each 29797.00 32884.00
900x750 Each 31089.00 34320.00
900X800 Each 33100.00 36474.00
1000x800 Each 37192.00 40926.00
1000x900 Each 40208.00 44301.00
3.17 Providing and laying in position
including testing following all
flanged cast iron crosses (all sizes
in mm)
80mm Dia Each 1795.00 1939.00
100mm Dia Each 2226.00 2441.00
125mm Dia Each 2944.00 3303.00
150mm Dia Each 3877.00 4308.00
200mm Dia Each 6031.00 6677.00
250mm Dia Each 8760.00 9693.00
300mm Dia Each 11847.00 12924.00
3.18 Providing and laying in position
including testing following all
flanged cast iron blank flanges (all
sizes in mm)
80mm Dia Each 323.00 359.00
100mm Dia Each 388.00 431.00
125mm Dia Each 517.00 574.00
150mm Dia Each 711.00 790.00
200mm Dia Each 1034.00 1149.00
250mm Dia Each 1486.00 1651.00
300mm Dia Each 2068.00 2298.00
350mm Dia Each 2779.00 3087.00
400mm Dia Each 3554.00 3949.00
450mm Dia Each 4330.00 4811.00
500mm Dia Each 5493.00 6103.00
600mm Dia Each 8142.00 9047.00
700mm Dia Each 11438.00 12709.00
750mm Dia Each 13376.00 14863.00
800mm Dia Each 15832.00 17591.00

41
S.No. ITEMS Unit Rates in Rs.
900mm Dia Each 20226.00 22473.00
1000mm Dia Each 26236.00 29151.00
3.19 Labour for laying in position Medium Class Heavy Class
including testing following cast
iron flanged sockets (all sizes in
mm)
80mm Dia Each 25.00 27.00
100mm Dia Each 32.00 34.00
125mm Dia Each 40.00 42.00
150mm Dia Each 53.00 55.00
200mm Dia Each 76.00 78.00
250mm Dia Each 122.00 131.00
300mm Dia Each 156.00 167.00
350mm Dia Each 198.00 211.00
400mm Dia Each 245.00 260.00
450mm Dia Each 283.00 300.00
500mm Dia Each 344.00 365.00
600mm Dia Each 466.00 494.00
700mm Dia Each 610.00 646.00
750mm Dia Each 692.00 732.00
800mm Dia Each 780.00 825.00
900mm Dia Each 949.00 1004.00
1000mm Dia Each 1157.00 1224.00
3.20 Labour for laying in position
including testing following cast
iron flanged Spigot (all sizes in Medium Class Heavy Class
mm)
80mm Dia Each 23.00 25.00
100mm Dia Each 27.00 30.00
125mm Dia Each 36.00 40.00
150mm Dia Each 44.00 49.00
200mm Dia Each 74.00 82.00
250mm Dia Each 99.00 112.00
300mm Dia Each 127.00 143.00
350mm Dia Each 160.00 179.00
400mm Dia Each 194.00 219.00
450mm Dia Each 230.00 260.00
500mm Dia Each 274.00 308.00
600mm Dia Each 424.00 479.00
700mm Dia Each 551.00 622.00
750mm Dia Each 625.00 705.00
800mm Dia Each 696.00 705.00
900mm Dia Each 836.00 1003.00
1000mm Dia Each 1005.00 1150.00

42
S.No. ITEMS Unit Rates in Rs.
3.21 Labour for laying in position
including testing following cast
iron double flanged 90° Bend (all Medium Class Heavy class
sizes in mm)
80mm Dia Each 25.00 27.00
100mm Dia Each 34.00 49.00
125mm Dia Each 44.00 65.00
150mm Dia Each 61.00 103.00
200mm Dia Each 95.00 152.00
250mm Dia Each 137.00 211.00
300mm Dia Each 190.00 289.00
350mm Dia Each 260.00 382.00
400mm Dia Each 342.00 477.00
450mm Dia Each 544.00 612.00
500mm Dia Each 827.00 933.00
600mm Dia Each 1194.00 1348.00
700mm Dia Each 1409.00 1593.00
750mm Dia Each 1663.00 1882.00
800mm Dia Each 1960.00 2219.00
900mm Dia Each 2582.00 2940.00
1000mm Dia Each 3389.00 3850.00
3.22 Labour for laying in position
including testing following cast
iron double flanged 45° bend (all
sizes in mm)
80mm Dia Each 27.00 30.00
100mm Dia Each 34.00 38.00
125mm Dia Each 47.00 53.00
150mm Dia Each 65.00 72.00
200mm Dia Each 103.00 114.00
250mm Dia Each 152.00 169.00
300mm Dia Each 213.00 236.00
350mm Dia Each 218.00 243.00
400mm Dia Each 283.00 314.00
450mm Dia Each 351.00 390.00
500mm Dia Each 439.00 487.00
600mm Dia Each 649.00 722.00
700mm Dia Each 921.00 1023.00
750mm Dia Each 1086.00 1207.00
3.23 Labour for laying in position
including testing following cast
iron double flanged 90° duck foot
bend. (all sizes in mm) Medium Class Heavy Class
80mm Dia Each 42.00 44.00
100mm Dia Each 53.00 55.00

43
S.No. ITEMS Unit Rates in Rs.
125mm Dia Each 72.00 76.00
150mm Dia Each 95.00 99.00
200mm Dia Each 148.00 156.00
250mm Dia Each 219.00 234.00
300mm Dia Each 308.00 329.00
350mm Dia Each 422.00 452.00
400mm Dia Each 553.00 593.00
450mm Dia Each 686.00 739.00
500mm Dia Each 874.00 941.00
600mm Dia Each 1323.00 1428.00
3.24 Labour for laying in position Medium Class Heavy Class
including testing following cast
iron all flanged tees (all sizes in
mm) Body x Branch
80x80 Each 42.00 44.00
100x80 Each 49.00 53.00
100x100 Each 51.00 55.00
125x80 Each 61.00 68.00
125x100 Each 68.00 72.00
125x125 Each 70.00 76.00
150x80 Each 80.00 87.00
150x100 Each 82.00 89.00
150x125 Each 87.00 95.00
150x150 Each 91.00 99.00
200x80 Each 118.00 131.00
200x100 Each 120.00 133.00
200x125 Each 127.00 139.00
200x150 Each 131.00 143.00
200x200 Each 141.00 156.00
250x80 Each 169.00 188.00
250x100 Each 171.00 190.00
250x125 Each 177.00 196.00
250x150 Each 184.00 203.00
250x200 Each 194.00 215.00
250x250 Each 209.00 230.00
300x80 Each 230.00 257.00
300x100 Each 234.00 262.00
300x125 Each 238.00 266.00
300x150 Each 245.00 272.00
300x200 Each 257.00 287.00
300x250 Each 272.00 302.00
300x300 Each 287.00 319.00
350x200 Each 321.00 357.00
350x250 Each 329.00 365.00
350x300 Each 359.00 397.00

44
S.No. ITEMS Unit Rates in Rs.
350x350 Each 369.00 411.00
400x200 Each 399.00 445.00
400x250 Each 407.00 454.00
400x300 Each 439.00 490.00
400x350 Each 452.00 504.00
400x400 Each 466.00 519.00
450x250 Each 490.00 549.00
450x300 Each 521.00 584.00
450x350 Each 534.00 599.00
450x400 Each 546.00 612.00
450x450 Each 559.00 625.00
500x250 Each 593.00 665.00
500x300 Each 629.00 705.00
500x350 Each 644.00 722.00
500x400 Each 658.00 736.00
500x450 Each 671.00 751.00
500x500 Each 686.00 766.00
600x300 Each 874.00 983.00
600x350 Each 895.00 1002.00
600x400 Each 912.00 1023.00
600x450 Each 924.00 1038.00
600x500 Each 939.00 1053.00
600x600 Each 973.00 1089.00
700x350 Each 1203.00 1355.00
700x400 Each 1220.00 1374.00
700x450 Each 1239.00 1393.00
700x500 Each 1255.00 1412.00
700x600 Each 1289.00 1447.00
700x700 Each 1334.00 1492.00
750x400 Each 1397.00 1574.00
750x450 Each 1414.00 1591.00
750x500 Each 1437.00 1616.00
750X600 Each 1464.00 1644.00
750x700 Each 1492.00 1671.00
750x750 Each 1519.00 1699.00
800x400 Each 1608.00 1810.00
800x450 Each 1625.00 1829.00
800x500 Each 1644.00 1850.00
800x600 Each 1684.00 1893.00
800x700 Each 1724.00 1933.00
800x750 Each 1747.00 1958.00
800x800 Each 1775.00 1986.00
900x450 Each 2038.00 2302.00
900x500 Each 2068.00 2334.00
900x600 Each 2110.00 2380.00

45
S.No. ITEMS Unit Rates in Rs.
900x700 Each 2152.00 2424.00
900x750 Each 2178.00 2450.00
900x800 Each 2203.00 2475.00
900x900 Each 2239.00 2511.00
3.25 Labour for laying in position
including testing following cast
iron double flanged Tapers (all
sizes in mm)
Body x Branch Medium Class Heavy Class
100x80 Each 23.00 25.00
125x80 Each 38.00 42.00
125x100 Each 42.00 46.00
150x80 Each 44.00 49.00
150x100 Each 49.00 53.00
150x125 Each 53.00 57.00
200x100 Each 61.00 65.00
200x125 Each 65.00 72.00
200x150 Each 72.00 78.00
250x125 Each 80.00 87.00
250x150 Each 84.00 93.00
250x200 Each 97.00 106.00
300x150 Each 99.00 108.00
300x200 Each 112.00 122.00
300x250 Each 127.00 137.00
350x200 Each 167.00 184.00
350x250 Each 184.00 203.00
350x300 Each 203.00 224.00
400x250 Each 207.00 230.00
400x300 Each 228.00 253.00
400x350 Each 251.00 279.00
450x300 Each 247.00 274.00
450x350 Each 276.00 306.00
450x400 Each 302.00 333.00
500x350 Each 304.00 338.00
500x400 Each 331.00 367.00
500x450 Each 354.00 392.00
600x400 Each 401.00 443.00
600x450 Each 422.00 468.00
600x500 Each 456.00 504.00
700x500 Each 536.00 593.00
700x600 Each 606.00 669.00
750x600 Each 646.00 713.00
750x700 Each 705.00 776.00
800x600 Each 726.00 802.00

46
S.No. ITEMS Unit Rates in Rs.
800x700 Each 785.00 865.00
800x750 Each 819.00 903.00
900x700 Each 876.00 966.00
900x750 Each 914.00 1009.00
900x800 Each 973.00 1072.00
1000x800 Each 1093.00 1203.00
1000x900 Each 1182.00 1302.00
3.26 Labour for laying in position Medium Class Heavy Class
including testing following all
flanged cast iron crosses (all sizes
in mm)
80mm Dia Each 53.00 57.00
100mm Dia Each 65.00 72.00
125mm Dia Each 87.00 97.00
150mm Dia Each 114.00 127.00
200mm Dia Each 177.00 196.00
250mm Dia Each 257.00 285.00
300mm Dia Each 348.00 380.00
3.27 Labour for laying in position
including testing following cast
iron blank flanges (all sizes in mm)
80mm Dia Each 9.00 11.00
100mm Dia Each 11.00 13.00
125mm Dia Each 15.00 17.00
150mm Dia Each 21.00 23.00
200mm Dia Each 30.00 34.00
250mm Dia Each 44.00 49.00
300mm Dia Each 61.00 68.00
350mm Dia Each 82.00 91.00
400mm Dia Each 104.00 116.00
450mm Dia Each 127.00 141.00
500mm Dia Each 161.00 179.00
600mm Dia Each 239.00 266.00
700mm Dia Each 336.00 373.00
750mm Dia Each 393.00 437.00
800mm Dia Each 465.00 517.00
900mm Dia Each 594.00 660.00
1000mm Dia Each 771.00 857.00
3.28 Providing and laying in position Medium Class Heavy Class
including testing following sizes
of flanged cast iron standard
specials class medium or heavy
which does not appear in above
items of the schedule
47
S.No. ITEMS Unit Rates in Rs.
80mm to 300mm dia Kg 62.00 62.00
Above 300mm dia Kg 71.00 71.00
3.29 Labour for laying in position
including testing following sizes of
flanges, cast iron standard specials
which does not appear in above
items of the schedule

80mm to 750mm dia Kg 2.00 2.00


3.30 Labour only for laying including
testing following Horizontal Cast
Iron Pipes in inclined or vertical
position
80mm to 750mm dia In truly vertical position 200% above
rates provided vide item No. 3.2, 3.4, 3.6.
In inclined position at inclination less
than 45% Same as rates provided vide
item No. 3.2, 3.4, 3.6

48
CHAPTER – IV

DUCTILE IRON PRESSURE PIPES WITH


(TYTON JOINTS)
VALVES AND SPECIALS

49
Chapter – IV
DUCTILE IRON PRESSURE PIPES WITH
(TYTON JOINTS) VALVES AND SPECIALS
NOTES:
1 All the pipes, specials, joints to be used in the work shall confirm to relevant
Indian standard duly inspected and tested and having B.I.S. certification mark.
2 The jointing materials i.e. Tyton rings if supplied by the Department from
departmental store, no extra charges for carting of the same to site of work will be
payable. In case jointing materials are required to be arranged by the contractor
the same should confirm to relevant Indian standard duly inspected and tested and
bearing B.I.S. certification Mark.
3 The rates include charges for all tools and plant, chain pulley blocks, other
appliances etc. required for lifting and laying the pipes and specials in position
including testing as per approved drawings.
4 The rates include provision and use of all coverings etc. to protect the work from
inclement weather etc. and from damages from falling materials and other causes.
5 The rate include provision of handling, storing under cover as required and
returning of empty cases or container to Public Health Engineering Department
Stores without any extra cost, for such materials as may be supplied by the
department.
6 All measurements should be of the finished work.
7 Fitting must of superior quality & equivalent to Kiswak /Electrosteel /Kejriwal
/Jindal.
8 Rates include the supply of pipes and specials at departmental store/site store.
9 Works will be executed in accordance with the general specifications in vogue in
P.H.E. Department and the specials notes if any, covered in the contract agreement
of the work and all the relevant latest version of I.S. Specifications as detailed
below;
S.No. I.S. Number Title
1. IS 8329:2000 Centrifugally cast (spun) ductile iron pressure pipes for
water, gas and sewage (Third revision)
2. IS 9523:2000 Ductile Iron fittings for pressure pipes for water, gas
and sewage.
3. IS 12288:1987 Code of practice for use and laying of ductile iron pipes.
4. IS 5328:1985 Rubber sealing rings for gas mains, water mains and
sewage (First revision)
5. IS 14846:2000 The Sluice Valves (50-1200 mm size)
6. IS 14845: 2000 The resilient seated C.I. Air relief valve
7. IS 5312: 2004 The Swing check type reflux valves

50
(Part I & II)
8. IS 13095:1991 The Butter fly valves

10. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.

DUCTILE IRON PRESSURE PIPES WITH


(TYTON JOINTS) VALVES AND SPECIALS

S. No. Items Unit Rates in Rs.


4.1 Providing, laying and jointing including testing
following socket & spigot centrifugally cast (Spun)
Ductile Iron pressure pipes with inside cement
mortar lining (class K-7) conforming to IS
8329/2000 with suitable Rubber Gasket (Push on)
joints as per IS:5382/85
100mm Dia Metre 927.00
150mm Dia Metre 1302.00
200mm Dia Metre 1704.00
250mm Dia Metre 2246.00
300mm Dia Metre 2860.00
350mm Dia Metre 3438.00
400mm Dia Metre 4167.00
450mm Dia Metre 4949.00
500mm Dia Metre 5930.00
600mm Dia Metre 7732.00
700mm Dia Metre 10731.00
750mm Dia Metre 12111.00
800mm Dia Metre 13594.00
900mm Dia Metre 16539.00
1000mm Dia Metre 19889.00
4.2 Labour for laying in position including testing
following socket & spigot Ductile Iron(K-7)
pressure pipes

100mm Dia Metre 21.00


150mm Dia Metre 29.00
200mm Dia Metre 44.00
250mm Dia Metre 58.00
300mm Dia Metre 73.00
350mm Dia Metre 97.00
400mm Dia Metre 116.00

51
S. No. Items Unit Rates in Rs.
450mm Dia Metre 137.00
500mm Dia Metre 160.00
600mm Dia Metre 211.00
700mm Dia Metre 268.00
750mm Dia Metre 351.00
800mm Dia Metre 445.00
900mm Dia Metre 547.00
1000mm Dia Metre 660.00
4.3 Providing, laying and jointing including testing
following socket & spigot centrifugally cast (Spun)
Ductile Iron pressure pipes with inside cement
mortar lining (class K-9) conforming to IS
8329/2000 with suitable Rubber Gasket (Push on)
joints as per IS:5382/85
100mm Dia Metre 1041.00
150mm Dia Metre 1469.00
200mm Dia Metre 2003.00
250mm Dia Metre 2679.00
300mm Dia Metre 3404.00
350mm Dia Metre 4124.00
400mm Dia Metre 4972.00
450mm Dia Metre 5887.00
500mm Dia Metre 6987.00
600mm Dia Metre 9113.00
700mm Dia Metre 11969.00
750mm Dia Metre 13263.00
800mm Dia Metre 14518.00
900mm Dia Metre 17654.00
1000mm Dia Metre 21213.00
4.4 Labour for laying in position including testing Metre
following socket & spigot Ductile Iron (K-9)
pressure pipes
100mm Dia Metre 21.00
150mm Dia Metre 29.00
200mm Dia Metre 44.00
250mm Dia Metre 58.00
300mm Dia Metre 73.00
350mm Dia Metre 97.00
400mm Dia Metre 116.00
450mm Dia Metre 137.00
500mm Dia Metre 160.00

52
S. No. Items Unit Rates in Rs.
600mm Dia Metre 211.00
700mm Dia Metre 268.00
750mm Dia Metre 351.00
800mm Dia Metre 445.00
900mm Dia Metre 547.00
1000mm Dia Metre 660.00
4.5 Providing Rubber ISI marked Gasket (push on)
joint as per IS-5382/85 to following DI pipes class
K-7 and K-9 including testing of joints and cost of
jointing materials (Rubber Gasket and soap
solution etc.)

100mm Dia Each 92.00


150mm Dia Each 117.00
200mm Dia Each 191.00
250mm Dia Each 228.00
300mm Dia Each 292.00
350mm Dia Each 335.00
400mm Dia Each 556.00
450mm Dia Each 640.00
500mm Dia Each 652.00
600mm Dia Each 808.00
700mm Dia Each 1123.00
750mm Dia Each 1233.00
800mm Dia Each 1306.00
900mm Dia Each 1566.00
1000mm Dia Each 1788.00
4.6 Labour for providing including testing,Rubber
Gasket (push on) joints to following D.I. Pipes
class K-7 & K-9 including joints but excluding
cost of Rubber Gasket.

100mm Dia Each 58.00


150mm Dia Each 65.00
200mm Dia Each 68.00
250mm Dia Each 82.00
300mm Dia Each 88.00
350mm Dia Each 102.00
400mm Dia Each 132.00
450mm Dia Each 146.00
500mm Dia Each 156.00

53
S. No. Items Unit Rates in Rs.
600mm Dia Each 190.00
700mm Dia Each 222.00
750mm Dia Each 232.00
800mm Dia Each 246.00
900mm Dia Each 289.00
1000mm Dia Each 310.00

DUCTILE IRON FITTING PN- 16


Note:- If PN-10 fitting is used than 90% of rate is payable in payable
for providing and fixing of fitting.

4.7 Providing and Laying including testing ductile


iron PN 16 type flanged sockets conforming to IS-
9523/2000 having dimension as per table 23 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal
cement mortar lining with finishing as per clause
13 of IS-9523/2000.

100mm Each 1016.00


150mm Each 1581.00
200mm Each 2371.00
250mm Each 3162.00
300mm Each 4178.00
350mm Each 6497.00
400mm Each 8256.00
450mm Each 10286.00
500mm Each 12993.00
600mm Each 17847.00
700mm Each 28380.00
750mm Each 31115.00
800mm Each 37783.00
900mm Each 47015.00
1000mm Each 60863.00
4.8 Labour only for Laying including testing Ductile
Iron PN 16 type flanged sockets conforming to IS-
9523/2000 having dimension as per table 23 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000.
100mm Each 19.00
150mm Each 30.00
200mm Each 44.00

54
S. No. Items Unit Rates in Rs.
250mm Each 59.00
300mm Each 78.00
350mm Each 101.00
400mm Each 129.00
450mm Each 160.00
500mm Each 203.00
600mm Each 260.00
700mm Each 350.00
750mm Each 384.00
800mm Each 466.00
900mm Each 580.00
1000mm Each 751.00
4.9 Providing and Laying including testing ductile PN
16 type iron flanged spigot conforming to IS-
9523/2000 having dimension as per table 24 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000.
100mm Each 1129.00
150mm Each 1807.00
200mm Each 2597.00
250mm Each 3613.00
300mm Each 4743.00
350mm Each 7579.00
400mm Each 9474.00
450mm Each 11910.00
500mm Each 14888.00
600mm Each 21520.00
700mm Each 33509.00
750mm Each 37954.00
800mm Each 42399.00
900mm Each 50776.00
1000mm Each 63428.00
4.10 Labour only for Laying including testing Ductile
Iron PN 16 type flanged Spigot conforming to IS-
9523/2000 having dimension as per table 24 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000.

100mm Each 21.00

55
S. No. Items Unit Rates in Rs.
150mm Each 34.00
200mm Each 49.00
250mm Each 68.00
300mm Each 89.00
350mm Each 118.00
400mm Each 148.00
450mm Each 186.00
500mm Each 232.00
600mm Each 335.00
700mm Each 414.00
750mm Each 468.00
800mm Each 523.00
900mm Each 627.00
1000mm Each 783.00
4.11 Providing and Laying including testing Ductile
iron Mechanical joint collar with follower glands
conforming to IS-9523/2000 having dimension as
per table 24 of IS-9523/2000 in the following
nominal diameter/sizes with external bitumen and
internal cement mortar lining.
100mm Each 2087.00
150mm Each 3072.00
200mm Each 3970.00
250mm Each 5986.00
300mm Each 7019.00
350mm Each 11152.00
400mm Each 13649.00
450mm Each 15606.00
500mm Each 18402.00
600mm Each 23356.00
700mm Each 43733.00
750mm Each 48903.00
800mm Each 55546.00
900mm Each 65344.00
1000mm Each 84234.00
4.12 Labour only for Laying including testing Ductile
Iron Mechanical Joint collar with follower glands
conforming to IS-9523/2000 having dimension as
per table 24 of IS-9523/2000 in the following
nominal diameter /sizes with internal cement
mortar lining.
100mm Each 46.00

56
S. No. Items Unit Rates in Rs.
150mm Each 65.00
200mm Each 82.00
250mm Each 118.00
300mm Each 137.00
350mm Each 190.00
400mm Each 222.00
450mm Each 253.00
500mm Each 295.00
600mm Each 371.00
700mm Each 557.00
750mm Each 620.00
800mm Each 701.00
900mm Each 817.00
1000mm Each 1021.00
4.13 Providing and Laying including testing Ductile
Iron Double Socket 90° Bends conforming to IS-
9523/2000 having dimension as per table 15 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.
100mm Each 1126.00
150 mm Each 2047.00
200mm Each 3276.00
250mm Each 4709.00
300mm Each 6654.00
350mm Each 11316.00
400mm Each 14698.00
450mm Each 19120.00
500mm Each 24323.00
600mm Each 32922.00
700mm Each 50249.00
750mm Each 62395.00
800mm Each 66920.00
900mm Each 88649.00
1000mm Each 110139.00
4.14 Labour only for Laying including testing Ductile
Iron Double Socket 90° Bends conforming to IS-
9523/2000 having dimension as per table 15 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.

57
S. No. Items Unit Rates in Rs.
100mm Each 23.00
150 mm Each 42.00
200mm Each 68.00
250mm Each 97.00
300mm Each 137.00
350mm Each 184.00
400mm Each 238.00
450mm Each 310.00
500mm Each 395.00
600mm Each 601.00
700mm Each 848.00
750mm Each 994.00
800mm Each 1179.00
900mm Each 1572.00
1000mm Each 2034.00
4.15 Providing and Laying including testing Ductile
Iron Double Socket 45° Bends conforming to IS-
9523/2000 having dimension as per table 16 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.
100mm Each 1024.00
125mm Each 1331.00
150 mm Each 1638.00
200mm Each 2662.00
250mm Each 3685.00
300mm Each 5016.00
350mm Each 8455.00
400mm Each 10666.00
450mm Each 13917.00
500mm Each 17559.00
600mm Each 26534.00
700mm Each 45654.00
750mm Each 52828.00
800mm Each 62611.00
900mm Each 82666.00
1000mm Each 106145.00
4.16 Labour only for Laying including testing Ductile
Iron Double Socket 45° Bends conforming to IS-
9523/2000 having dimension as per table 16 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.

58
S. No. Items Unit Rates in Rs.
100mm Each 21.00
125mm Each 27.00
150 mm Each 34.00
200mm Each 55.00
250mm Each 76.00
300mm Each 103.00
350mm Each 137.00
400mm Each 173.00
450mm Each 226.00
500mm Each 285.00
600mm Each 430.00
700mm Each 591.00
750mm Each 684.00
800mm Each 810.00
900mm Each 1070.00
1000mm Each 1374.00
4.17 Providing and Laying including testing Ductile
Iron Double Socket 22.5° Bends conforming to IS-
9523/2000 having dimension as per table 17 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.
100mm Each 921.00
125mm Each 1228.00
150 mm Each 1433.00
200mm Each 2252.00
250mm Each 3173.00
300mm Each 4197.00
350mm Each 6764.00
400mm Each 8715.00
450mm Each 11056.00
500mm Each 13917.00
600mm Each 20358.00
700mm Each 34892.00
750mm Each 40110.00
800mm Each 47447.00
900mm Each 61469.00
1000mm Each 74676.00

59
S. No. Items Unit Rates in Rs.
4.18 Labour only for Laying including testing Ductile
Iron Double Socket 22.5° Bends conforming to IS-
9523/2000 having dimension as per table 17 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining.
100mm Each 19.00
125mm Each 25.00
150 mm Each 30.00
200mm Each 46.00
250mm Each 65.00
300mm Each 87.00
350mm Each 110.00
400mm Each 141.00
450mm Each 179.00
500mm Each 226.00
600mm Each 331.00
700mm Each 452.00
750mm Each 519.00
800mm Each 614.00
900mm Each 795.00
1000mm Each 966.00
4.19 Providing and Laying including testing Ductile
Iron Double Socket 11.25° bends conforming to
IS-9523/2000 having dimension as per table 18 of
IS-9523/2000 in the following nominal diameter/
sizes with external bitumen coating and internal
cement mortar lining
100mm Each 921.00
125mm Each 1126.00
150 mm Each 1331.00
200mm Each 2150.00
250mm Each 2866.00
300mm Each 3788.00
350mm Each 5983.00
400mm Each 7414.00
450mm Each 9495.00
500mm Each 11836.00
600mm Each 17299.00
700mm Each 28697.00
750mm Each 32773.00
800mm Each 39458.00
900mm Each 52719.00
1000mm Each 62611.00

60
S. No. Items Unit Rates in Rs.
4.20 Labour only for Laying including testing Ductile
Iron Double Socket 11.25° bends conforming to
IS-9523/2000 having dimension as per table 18 of
IS-9523/2000 in the following nominal diameter
/sizes with external bitumen coating and internal
cement mortar lining.
100mm Each 19.00
125mm Each 23.00
150 mm Each 27.00
200mm Each 44.00
250mm Each 59.00
300mm Each 78.00
350mm Each 97.00
400mm Each 120.00
450mm Each 154.00
500mm Each 192.00
600mm Each 281.00
700mm Each 371.00
750mm Each 424.00
800mm Each 511.00
900mm Each 652.00
1000mm Each 810.00
4.21 Providing and Laying including testing Ductile
Iron All socket Tees conforming to IS-9523/2000
having dimension as per table 21 of IS-9523/2000
in the following nominal diameter/sizes with
external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000.
100mm x 80mm Each 1433.00
100mm x 100mm Each 1536.00
150mm x 80mm Each 1945.00
150mm x 100mm Each 2150.00
150mm x 150mm Each 2457.00
200mm x 80mm Each 2866.00
200mm x 100mm Each 3071.00
200mm x 150mm Each 3574.00
200mm x 200mm Each 4095.00
250mm x 80mm Each 3685.00
250mm x 100mm Each 3890.00
250mm x 150mm Each 4402.00

61
S. No. Items Unit Rates in Rs.
250mm x 250mm Each 5630.00
300mm x 100mm Each 5016.00
300mm x 200mm Each 6347.00
300mm x 300mm Each 7882.00
4.22 Labour only for Laying including testing Ductile
Iron All socket Tees conforming to IS-9523/2000
having dimension as per table 21 of IS-9523/2000
in the following nominal diameter/sizes with
external bitumen coating and internal cement
mortar lining.
100mm x 80mm Each 30.00
100mm x 100mm Each 32.00
150mm x 80mm Each 40.00
150mm x 100mm Each 44.00
150mm x 150mm Each 51.00
200mm x 80mm Each 59.00
200mm x 100mm Each 63.00
200mm x 150mm Each 72.00
200mm x 200mm Each 84.00
250mm x 80mm Each 76.00
250mm x 100mm Each 80.00
250mm x 150mm Each 91.00
250mm x 250mm Each 116.00
300mm x 100mm Each 103.00
300mm x 200mm Each 131.00
300mm x 300mm Each 162.00
4.23 Providing and Laying including testing Ductile
Iron Double Socket branch flange Tee conforming
to IS-9523/2000 having dimension as per table 21
of IS-9523/2000 in the following nominal
diameter/sizes with external bitumen coating and
internal cement mortar lining with finishing as
per clause 13 of IS-9523/2000.
100mm x 80mm Each 1694.00
100mm x 100mm Each 1807.00
150mm x 80mm Each 2371.00
150mm x 100mm Each 2484.00
150mm x 150mm Each 3049.00
62
S. No. Items Unit Rates in Rs.
200mm x 80mm Each 3275.00
200mm x 100mm Each 3501.00
200mm x 150mm Each 4065.00
200mm x 200mm Each 4743.00
250mm x 80mm Each 4178.00
250mm x 100mm Each 4404.00
250mm x 150mm Each 5081.00
250mm x 200mm Each 5759.00
250mm x 250mm Each 6662.00
300mm x 80mm Each 5432.00
300mm x 100mm Each 5646.00
300mm x 150mm Each 6436.00
300mm x 200mm Each 7227.00
300mm x 250mm Each 8243.00
300mm x 300mm Each 9372.00
350mm x 100mm Each 8121.00
350mm x 200mm Each 10151.00
350mm x 350mm Each 14617.00
400mm x 80mm Each 9204.00
400mm x 100mm Each 9745.00
400mm x 150mm Each 10963.00
400mm x 200mm Each 12011.00
400mm x 300mm Each 15023.00
400mm x 400mm Each 18813.00
450mm x 100mm Each 12046.00
450mm x 250mm Each 16242.00
500mm x 100mm Each 14482.00
500mm x 200mm Each 17460.00
500mm x 400mm Each 25174.00
500mm x 500mm Each 30724.00
600mm x 200mm Each 24092.00
4.24 Labour only for Laying including testing Ductile
Iron Double Socketed Branch Flange Tee
Conforming to IS-9523/2000 having dimension as
per table 21 of IS-9523/2000 in the following
nominal diameter/sizes with external bitumen
coating and internal cement mortar lining.
100mm x 80mm Each 32.00
100mm x 100mm Each 34.00
150mm x 80mm Each 44.00

63
S. No. Items Unit Rates in Rs.
150mm x 100mm Each 46.00
150mm x 150mm Each 57.00
200mm x 80mm Each 61.00
200mm x 100mm Each 65.00
200mm x 150mm Each 76.00
200mm x 200mm Each 89.00
250mm x 80mm Each 78.00
250mm x 100mm Each 82.00
250mm x 150mm Each 95.00
250mm x 200mm Each 108.00
250mm x 250mm Each 124.00
300mm x 80mm Each 101.00
300mm x 100mm Each 106.00
300mm x 150mm Each 120.00
300mm x 200mm Each 135.00
300mm x 250mm Each 154.00
300mm x 300mm Each 175.00
350mm x 100mm Each 127.00
350mm x 200mm Each 158.00
350mm x 350mm Each 228.00
400mm x 80mm Each 143.00
400mm x 100mm Each 152.00
400mm x 150mm Each 171.00
400mm x 200mm Each 188.00
400mm x 300mm Each 234.00
400mm x 400mm Each 293.00
450mm x 100mm Each 188.00
450mm x 250mm Each 253.00
500mm x 100mm Each 226.00
500mm x 200mm Each 272.00
500mm x 400mm Each 392.00
500mm x 500mm Each 479.00
600mm x 200mm Each 376.00
4.25 Providing and Laying including testing Ductile
Iron Double Socket Reducer conforming to IS-
9523/2000 having dimension as per table 21 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000.
100mm x 80mm Each 823.00
150mm x 80mm Each 1333.00
150mm x 100mm Each 1331.00
200mm x 100mm Each 2043.00
64
S. No. Items Unit Rates in Rs.
200mm x 150mm Each 1951.00
250mm x 150mm Each 2764.00
300mm x 150mm Each 3777.00
300mm x 200mm Each 3886.00
300mm x 250mm Each 3593.00
350mm x 200mm Each 6373.00
350mm x 250mm Each 6115.00
350mm x 300mm Each 5868.00
400mm x 250mm Each 8066.00
400mm x 300mm Each 7678.00
400mm x 350mm Each 7179.00
450mm x 350mm Each 9499.00
450mm x 400mm Each 9004.00
500mm x 350mm Each 12256.00
500mm x 400mm Each 11667.00
600mm x 400mm Each 18113.00
600mm x 500mm Each 16908.00
4.26 Labour only for laying including testing ductile
iron double socket reducer conforming to IS-
9523/2000 having dimension as per table 20 of IS-
9523/2000 in the following nominal diameter/sizes
with external bitumen coating and internal cement
mortar lining with finishing as per clause 13 of IS-
9523/2000
100mm x 80mm Each 21.00
150mm x 80mm Each 30.00
150mm x 100mm Each 27.00
200mm x 100mm Each 38.00
200mm x 150mm Each 46.00
250mm x 150mm Each 57.00
300mm x 150mm Each 68.00
300mm x 200mm Each 76.00
300mm x 250mm Each 84.00
350mm x 200mm Each 103.00
350mm x 250mm Each 101.00
350mm x 300mm Each 110.00
400mm x 250mm Each 133.00
400mm x 300mm Each 129.00
400mm x 350mm Each 141.00
450mm x 350mm Each 158.00
450mm x 400mm Each 175.00
500mm x 350mm Each 228.00

65
S. No. Items Unit Rates in Rs.
500mm x 400mm Each 279.00
600mm x 400mm Each 327.00
600mm x 500mm Each 401.00
4.27 Providing , Laying including testing and Jointing
of welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 1m. for class K-9
with inside cement mortar lining for the following
sizes/dia pipes.
100mm Dia Each 3047.00
150mm Dia Each 3974.00
200mm Dia Each 5234.00
250mm Dia Each 6664.00
300mm Dia Each 8126.00
350mm Dia Each 10243.00
400mm Dia Each 12506.00
450mm Dia Each 16879.00
500mm Dia Each 18956.00
600mm Dia Each 25071.00
700mm Dia Each 31285.00
750mm Dia Each 36381.00
800mm Dia Each 38385.00
900mm Dia Each 47044.00
1000mm Dia Each 56761.00
4.28 Providing, Laying including testing and Jointing
of welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 2m. for class K-9
with inside cement mortar, lining for the
following sizes/dia pipes.
100mm Dia Each 5519.00
150mm Dia Each 7356.00
200mm Dia Each 9796.00
250mm Dia Each 12639.00
300mm Dia Each 15324.00
350mm Dia Each 19530.00
400mm Dia Each 23751.00
450mm Dia Each 31986.00
500mm Dia Each 35788.00
600mm Dia Each 47739.00

66
S. No. Items Unit Rates in Rs.
4.29 Providing , Laying including testing and Jointing
of welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 3 m for class K-9
with inside cement mortar, lining for the
following sizes/dia pipes
100mm Dia Each 8054.00
150mm Dia Each 10804.00
200mm Dia Each 14424.00
250mm Dia Each 18680.00
300mm Dia Each 22638.00
350mm Dia Each 28888.00
400mm Dia Each 35068.00
450mm Dia Each 47166.00
500mm Dia Each 52695.00
600mm Dia Each 70485.00
4.30 Providing, Laying including testing and Jointing
welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to IS
8329/2000 in the length of 4m for class K-9 with
inside cement mortar lining for the following
sizes/dia pipes.
100mm Dia Each 10589.00
150mm Dia Each 14252.00
200mm Dia Each 19051.00
250mm Dia Each 24722.00
300mm Dia Each 29952.00
350mm Dia Each 38245.00
400mm Dia Each 46385.00
450mm Dia Each 62346.00
500mm Dia Each 69603.00
600mm Dia Each 93231.00
4.31 Providing, Laying including testing and Jointing
welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 4.5 m. for class K-9
with inside cement mortar lining for the following
sizes/dia pipes.
100mm Dia Each 11856.00
150mm Dia Each 15975.00
200mm Dia Each 21365.00
250mm Dia Each 27743.00

67
S. No. Items Unit Rates in Rs.
300mm Dia Each 33488.00
350mm Dia Each 42924.00
400mm Dia Each 52044.00
450mm Dia Each 69937.00
500mm Dia Each 78056.00
600mm Dia Each 104604.00
4.32 Providing, Laying including testing and Jointing
welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 5m. for class K-9
with inside cement mortar lining for the following
sizes/dia pipes.
100mm Dia Each 13124.00
150mm Dia Each 17699.00
200mm Dia Each 23679.00
250mm Dia Each 30763.00
300mm Dia Each 37266.00
350mm Dia Each 47602.00
400mm Dia Each 57702.00
450mm Dia Each 77527.00
500mm Dia Each 86510.00
600mm Dia Each 115977.00
4.33 Providing, Laying including testing and Jointing
of welded double flanged centrifugal cast (spun)
ductile Iron pressure pipes conforming to
IS:8329/2000 in the length of 5.2m. for class K-9
with inside cement mortar lining for the following
sizes/dia pipes
100mm Dia Each 13631.00
150mm Dia Each 18389.00
200mm Dia Each 24604.00
250mm Dia Each 31972.00
300mm Dia Each 38574.00
350mm Dia Each 49474.00
400mm Dia Each 59966.00
450mm Dia Each 80563.00
500mm Dia Each 89891.00
600mm Dia Each 120527.00
4.34 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes conforming to IS:8329/2000 in the
length of 1m. for class K-9 with inside cement
mortar lining for the following sizes/dia pipes
100mm Dia Each 53.00
150mm Dia Each 84.00

68
S. No. Items Unit Rates in Rs.
200mm Dia Each 114.00
250mm Dia Each 152.00
300mm Dia Each 194.00
350mm Dia Each 238.00
400mm Dia Each 285.00
450mm Dia Each 333.00
500mm Dia Each 390.00
600mm Dia Each 521.00
4.35 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes confirming to IS: 8329/2000 in the
length of 2m. for class K-9 with inside cement
mortar lining for the following sizes/dia pipes.
100mm Dia Each 91.00
150mm Dia Each 148.00
200mm Dia Each 198.00
250mm Dia Each 266.00
300mm Dia Each 340.00
350mm Dia Each 418.00
400mm Dia Each 500.00
450mm Dia Each 589.00
500mm Dia Each 688.00
600mm Dia Each 914.00
4.36 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes conforming to IS: 8329/2000 in the
length of 3m. for class K-9 with inside cement
mortar, lining for the following sizes/dia pipes.
100mm Dia Each 129.00
150mm Dia Each 211.00
200mm Dia Each 283.00
250mm Dia Each 380.00
300mm Dia Each 534.00
350mm Dia Each 597.00
400mm Dia Each 715.00
450mm Dia Each 844.00
500mm Dia Each 985.00
600mm Dia Each 1306.00

69
S. No. Items Unit Rates in Rs.
4.37 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes conforming to IS: 8329/2000 in the
length of 4m. for class K-9 with inside cement
mortar, lining for the following sizes/dia pipes
100mm Dia Each 167.00
150mm Dia Each 274.00
200mm Dia Each 367.00
250mm Dia Each 494.00
300mm Dia Each 728.00
350mm Dia Each 776.00
400mm Dia Each 931.00
450mm Dia Each 1099.00
500mm Dia Each 1283.00
600mm Dia Each 1699.00
4.38 Labour only for Laying including testing and
Jointing welded double flanged centrifugal cast
(spun) ductile Iron pressure pipes conforming to
IS: 8329/2000 in the length of 4.5m. for class K-9
with inside cement mortar, lining for the following
sizes/dia pipe
100mm Dia Each 186.00
150mm Dia Each 306.00
200mm Dia Each 409.00
250mm Dia Each 551.00
300mm Dia Each 704.00
350mm Dia Each 866.00
400mm Dia Each 1038.00
450mm Dia Each 1227.00
500mm Dia Each 1432.00
600mm Dia Each 1895.00
4.39 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes conforming to IS: 8329/2000 in the
length of 5m. for class K-9 with inside cement
mortar lining for the following sizes/dia pipes.
100mm Dia Each 205.00
150mm Dia Each 338.00
200mm Dia Each 452.00
250mm Dia Each 608.00
300mm Dia Each 922.00
350mm Dia Each 956.00

70
S. No. Items Unit Rates in Rs.
400mm Dia Each 1146.00
450mm Dia Each 1355.00
500mm Dia Each 1580.00
600mm Dia Each 2091.00
4.40 Labour only for Laying including testing welded
double flanged centrifugal cast (spun) ductile Iron
pressure pipes conforming to IS:8329/2000 in the
length of 5.2m for class K-9 with inside cement
mortar lining for the following sizes/dia pipes.
100mm Dia Each 212.00
150mm Dia Each 350.00
200mm Dia Each 468.00
250mm Dia Each 630.00
300mm Dia Each 806.00
350mm Dia Each 992.00
400mm Dia Each 1189.00
450mm Dia Each 1406.00
500mm Dia Each 1640.00
600mm Dia Each 2170.00

DUCTILE IRON VALVES


S. No. Item Unit Rates inRs.
4.41 Providing & fixing of following Ductile iron CLASS CLASS PN-
double flanged sluice valves as per PN- 10 16
I.S.:14846-2000 fitted with cap including
jointing & testing with cost of jointing
material such as bolts, nuts, rubber
insertions etc. all complete
80mm dia Each 6486.00 6799.00
100mm dia Each 8717.00 9136.00
150mm dia Each 13296.00 11986.00
200mm dia Each 21645.00 21961.00
250mm dia Each 30919.00 41126.00
300mm dia Each 48535.00 54205.00
350mm dia Each 71260.00 85086.00
400mm dia Each 107438.00 107438.00
450mm dia Each 151161.00 151161.00
500mm dia Each 201969.00 201969.00

71
S. No. Item Unit Rates inRs.
4.42 Fixing of following Ductile iron double CLASS PN-10/PN-16
flanged sluice valves fitted with cap testing
with cost of jointing material such as bolts,
nuts, rubber insertions etc. all complete
(only valve to be supplied by deptt. free of
cost.
80mm dia Each 225.00
100mm dia Each 352.00
150mm dia Each 511.00
200mm dia Each 706.00
250mm dia Each 1141.00
300mm dia Each 1290.00
350 mm dia Each 2128.00
400 mm dia Each 3267.00
450 mm dia Each 3953.00
500 mm dia Each 4990.00
4.43 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron double flanged sluice valves
(vide item no.1) including jointing and
testing but without cost of Jointing
materials.
80mm dia Each 107.00
100mm dia Each 148.00
150mm dia Each 216.00
200mm dia Each 323.00
250mm dia Each 464.00
300mm dia Each 599.00
350 mm dia Each 1046.00
400 mm dia Each 1237.00
450 mm dia Each 1479.00
500 mm dia Each 1790.00
4.44 Providing & fixing following ductile iron CLASS CLASS PN-
double flanged check valvewithout damper PN- 10 16
(non-returnvalve) including jointing &
testing with cost of jointing material such
as bolts,nuts and rubber insertion all
complete as per IS : 5312 (Part II)
200mm dia Each 21481.00 21797.00
250mm dia Each 30548.00 40755.00
300mm dia Each 48467.00 57916.00
350 mm dia Each 70920.00 84746.00
400 mm dia Each 106865.00 106865.00
500 mm dia Each 202073.00 202073.00
600 mm dia Each 315199.00 315199.00
4.45 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron double flanged check valve
without damper (non-return
valve)including jointing & testing with cost
of jointing material such as bolts,nuts and

72
S. No. Item Unit Rates inRs.
rubber insertion all complete as per IS :
5312 (Part II)
200mm dia Each 542.00
250mm dia Each 770.00
300mm dia Each 1222.00
350 mm dia Each 1788.00
400 mm dia Each 2694.00
500 mm dia Each 5094.00
600 mm dia Each 7946.00
4.46 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron double flanged check valve
without damper (non-return
valve)excluding jointing & testing with cost
of jointing material such as bolts,nuts and
rubber insertion all complete as per IS :
5312 (Part II)
200mm dia Each 206.00
250mm dia Each 337.00
300mm dia Each 428.00
350 mm dia Each 657.00
400 mm dia Each 856.00
500 mm dia Each 1203.00
600 mm dia Each 1829.00
4.47 Providing & fixing following ductile iron CLASS CLASS PN-
butterfly valves including jointing & PN- 10 16
testing with cost of jointing material such
as bolts, nuts and rubber insertion all
complete as per IS :13095-1991
100mm dia Each 6300.00 7940.00
150mm dia Each 7380.00 9288.00
200mm dia Each 9977.00 12557.00
250mm dia Each 14709.00 20337.00
300mm dia Each 17650.00 26253.00
350mm dia Each 49644.00 62471.00
400mm dia Each 59215.00 74518.00
450mm dia Each 69943.00 88099.00
500mm dia Each 96720.00 121703.00
4.48 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron butterfly valves including
jointing & testing but without cost of
jointing materials
100mm dia Each 118.00
150mm dia Each 136.00
200mm dia Each 166.00
250mm dia Each 206.00
300mm dia Each 337.00
350mm dia Each 484.00
400mm dia Each 577.00

73
S. No. Item Unit Rates inRs.
450mm dia Each 682.00
500mm dia Each 943.00
4.49 Labour for laying and fixing of following CLASS PN-10/PN-16
Ductile Iron butterfly valves including
jointing & testing but with cost of jointing
materials
100mm dia Each 159.00
150mm dia Each 186.00
200mm dia Each 252.00
250mm dia Each 371.00
300mm dia Each 445.00
350mm dia Each 1252.00
400mm dia Each 1493.00
450mm dia Each 1763.00
500mm dia Each 2438.00
4.50 Providing & fixing following ductile iron CLASS CLASS PN-
single chamber triple function temper PN- 10 16
proof air valves, small orifice with screwed
end as per IS : 14845-2000 including
jointing & testing with cost of jointing
material and rubber insertion all complete
as per IS :13095-1991
50mm dia Each 6137.00 6436.00
80mm dia Each 6423.00 6736.00
100mm dia Each 8582.00 9000.00
150mm dia Each 11771.00 11771.00
4.51 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron single chamber triple function
temper proof air valves small orifice with
screwed end i/c jointing & testing but
without cost of jointing material.
50mm dia Each 60.00
80mm dia Each 86.00
100mm dia Each 118.00
150mm dia Each 136.00
4.52 Labour for laying and fixing of following CLASS PN-10/PN-16
ductile iron single chamber triple function
temper proof Air valves small orifice with
screwed end i/c jointing & testing but with
cost of jointing material.
50mm dia Each 155.00
80mm dia Each 162.00
100mm dia Each 216.00
150mm dia Each 297.00

74
CHAPTER – V

ASBESTOS CEMENT PRESSURE PIPES

AND

CAST IRON FITTINGS

75
Chapter – V
ASBESTOS CEMENT PRESSURE PIPES AND CAST IRON FITTINGS
NOTES:

1. The A.C.P. pipes shall be confirming to IS - 1592:1980


2. The laying of A.C.P pipes shall be done as per IS - 6530: 1972
3. C.I. specials for A.C.P. pipes shall be done as per IS - 5531:1977
4. The C.I.D. joints shall be confirming to IS - 8794:1988
5. The rubber sealing of the D. Joint shall be confirming to IS - 10292:1988
6. All measurements shall be of the finished work.
7. Work shall be executed in accordance with the Indian Standards Specifications
and special notes if any, covered in the agreement of the work.
8. This USOR contains the rates of all the items without GST. GST shall be paid
separately as per prevailing government norms as claimed by the contractor
in his bill.
All the estimates based on this USOR will include GST as an extra amount as
per prevailing rates on the sum of the estimate to arrive at the gross amount.

ASBESTOS CEMENT PRESSURE PIPES AND CAST IRON FITTINGS

Item Items Unit Rate in Rupees


No.
Class 15 Class 20 Class 25
5.1 Providing, laying and jointing of
following Asbestos cement pressure
pipe ISI marked and conforming to IS-
1592/03 tested to the required pressure
including testing of joints, cost of pipes
& detachable joint ISI marked
conforming to IS/8794/1988 all
complete manufactured by mazza
process
80mm Dia Mtr. 266.00 296.00 333.00
100mm Dia Mtr. 351.00 430.00 519.00
125 mm Dia Mtr. 459.00 554.00 678.00
150mm Dia Mtr. 624.00 758.00 934.00
200mm Dia Mtr. 1019.00 1277.00 1582.00
250mm Dia Mtr. 1322.00 1729.00 2040.00
300mm Dia Mtr. 1799.00 2293.00 2860.00
350 mm Dia Mtr. 2321.00 2911.00 3547.00

76
Item Items Unit Rate in Rupees
No.
5.2 Providing, laying and jointing of
following Asbestos cement pressure
pipe with A.C. coupler Joint ISI
marked and conforming to IS-1592/03
tested to the required pressure
including testing of joints, cost of pipes
all complete manufactured by mazza
process
80mm Dia Mtr. 361.00 381.00 350.00
100mm Dia Mtr. 485.00 567.00 662.00
125 mm Dia Mtr. 603.00 697.00 826.00
150mm Dia Mtr. 702.00 827.00 991.00
200mm Dia Mtr. 1068.00 1290.00 1580.00
250mm Dia Mtr. 1375.00 1691.00 2054.00
300mm Dia Mtr. 1825.00 2290.00 2844.00
350 mm Dia Mtr. 2285.00 2884.00 3537.00
5.3 Labour for laying in position including
testing following Asbestos cement
pressure pipes class 15,20,25
80mm Dia Mtr. 7.00 7.00 7.00
100mm Dia Mtr. 8.00 8.00 8.00
125 mm Dia Mtr. 11.00 11.00 11.00
150mm Dia Mtr. 13.00 13.00 13.00
200mm Dia Mtr. 21.00 21.00 21.00
250mm Dia Mtr. 27.00 27.00 27.00
300mm Dia Mtr. 35.00 35.00 35.00
350 mm Dia Mtr. 43.00 43.00 43.00
5.4 Providing detachable joints to
following asbestos cement pressure
pipes and fittings including C.I.
detachable joints confirming to
IS/8794/1988 with bolts, nuts and
rubber rings confirming to IS- 5382/85
& IS- 10292/88 manufactured by
mazza process including testing
80mm Dia Each 294.00 318.00 341.00
100mm Dia Each 360.00 394.00 406.00
125 mm Dia Each 475.00 506.00 539.00
150mm Dia Each 552.00 595.00 648.00
200mm Dia Each 748.00 861.00 914.00
250mm Dia Each 997.00 1148.00 1221.00
300mm Dia Each 1209.00 1424.00 1517.00
350 mm Dia Each 1849.00 1852.00 1854.00

77
Item Items Unit Rate in Rupees
No.
5.5 Labour for providing detachable joints
to following asbestos cement pressure
pipes and fittings class 15, 20 & 25
including testing of joints but excluding
cost of C.I. Detachable joints.
80mm Dia Each 86.00 88.00 91.00
100mm Dia Each 101.00 103.00 106.00
125 mm Dia Each 116.00 118.00 121.00
150mm Dia Each 131.00 133.00 136.00
200mm Dia Each 146.00 148.00 151.00
250mm Dia Each 161.00 164.00 166.00
300mm Dia Each 176.00 179.00 181.00
350 mm Dia Each 191.00 194.00 196.00
5.6 Providing A.C. Coupler joints to
following A.C. pressure pipes
confirming to IS specification including
testing of joints rubber ring complete
manufactured by mazza process
80mm Dia Each 138.00 146.00 160.00
100mm Dia Each 146.00 154.00 173.00
125 mm Dia Each 234.00 260.00 314.00
150mm Dia Each 361.00 435.00 523.00
200mm Dia Each 384.00 481.00 615.00
250mm Dia Each 559.00 761.00 863.00
300mm Dia Each 881.00 1207.00 1524.00
350 mm Dia Each 2199.00 2263.00 2326.00
5.7 Labour for providing A.C. Coupler
joint for the following asbestos cement
pressure pipes and fittings class 15, 20
& 25 including testing of joint but
excluding cost of A.C. Coupler and
rubber rings
80mm Dia Each 68.00 70.00 73.00
100mm Dia Each 81.00 83.00 86.00
125 mm Dia Each 93.00 93.00 96.00
150mm Dia Each 103.00 106.00 108.00
200mm Dia Each 116.00 118.00 121.00
250mm Dia Each 128.00 131.00 133.00
300mm Dia Each 141.00 143.00 146.00
350 mm Dia Each 151.00 151.00 151.00
5.8 Providing & laying in position including
testing following cast iron plain ended
standard specials confirming to
IS/5531/1988 (Reaffirmed 2002)
manufactured by mazza process
78
Item Items Unit Rate in Rupees
No.
(i) Cast Iron Plain ended 90° Bend Class 15 Class 20 Class 25
80mm Dia Each 545.00 624.00 703.00
100mm Dia Each 760.00 932.00 1054.00
125 mm Dia Each 1061.00 1291.00 1463.00
150mm Dia Each 1506.00 1843.00 2072.00
200mm Dia Each 2617.00 3205.00 3621.00
250mm Dia Each 3829.00 4689.00 5191.00
300mm Dia Each 5593.00 6869.00 7600.00
350 mm Dia Each 7529.00 9178.00 10683.00
(ii) Cast Iron Plain ended 45° Bend Class 15 Class 20 Class 25
80mm Dia Each 552.00 631.00 710.00
100mm Dia Each 746.00 918.00 1040.00
125 mm Dia Each 1004.00 1233.00 1398.00
150mm Dia Each 1405.00 1714.00 1943.00
200mm Dia Each 2337.00 2882.00 3291.00
250mm Dia Each 3284.00 4051.00 4553.00
300mm Dia Each 4675.00 5786.00 6553.00
350 mm Dia Each 6095.00 7529.00 8819.00
(iii) Cast Iron Plain ended 22½° Bend Class 15 Class 20 Class 25
80mm Dia Each 409.00 466.00 545.00
100mm Dia Each 552.00 688.00 803.00
125 mm Dia Each 731.00 911.00 1076.00
150mm Dia Each 1032.00 1276.00 1506.00
200mm Dia Each 1721.00 2151.00 2567.00
250mm Dia Each 2345.00 2947.00 3449.00
300mm Dia Each 3327.00 4194.00 4962.00
350 mm Dia Each 4230.00 5342.00 6446.00
(iv) Cast Iron Plain ended 11¼° Bend Class 15 Class 20 Class 25
80mm Dia Each 337.00 380.00 459.00
100mm Dia Each 452.00 574.00 688.00
125 mm Dia Each 595.00 746.00 911.00
150mm Dia Each 846.00 1054.00 1283.00
200mm Dia Each 1412.00 1793.00 2208.00
250mm Dia Each 1871.00 2395.00 2897.00
300mm Dia Each 2653.00 3406.00 4166.00
350 mm Dia Each 3305.00 4252.00 5241.00
(v) Cast Iron Plain ended Tees
Body & Branch Class 15 Class 20 Class 25
80x80mm Each 695.00 796.00 918.00
100x80mm Each 903.00 1040.00 1176.00
100x100mm Each 997.00 1233.00 1412.00
125X80mm Each 1147.00 1362.00 1527.00
125X100mm Each 1269.00 1620.00 1821.00
125X125mm Each 1427.00 1749.00 1993.00

79
Item Items Unit Rate in Rupees
No.
150x80mm Each 1735.00 2101.00 2366.00
150x100mm Each 1814.00 2223.00 2510.00
150X125mm Each 1914.00 2345.00 2660.00
150x150mm Each 2086.00 2553.00 2890.00
200X80 mm Each 2968.00 3641.00 4073.00
200X100 mm Each 3054.00 3743.00 4216.00
200X125mm Each 3162.00 3872.00 4374.00
200X150 mm Each 3391.00 4087.00 4610.00
200X200 mm Each 3736.00 4589.00 5213.00
250X80 mm Each 4388.00 4632.00 5887.00
250X100 mm Each 4474.00 5478.00 6037.00
250X125mm Each 4596.00 5621.00 6209.00
250X150 mm Each 4775.00 5844.00 6460.00
250X200 mm Each 5198.00 6367.00 7077.00
250X250 mm Each 5585.00 6862.00 7600.00
(vi) Cast Iron Plain ended Tees
300x80 to 350x350mm
Body & Branch Class 15 Class 20 Class 25
300X80mm Each 6460.00 7887.00 8676.00
300X100mm Each 6546.00 8030.00 8819.00
300X125mm Each 6675.00 8174.00 9034.00
300X150mm Each 6783.00 8317.00 9178.00
300X200mm Each 7313.00 8963.00 9895.00
300X250mm Each 7744.00 9464.00 10181.00
300X300mm Each 8317.00 10253.00 11400.00
350X200mm Each 9680.00 11831.00 13695.00
350X250mm Each 10110.00 12332.00 14340.00
350X300mm Each 10755.00 13121.00 15272.00
350X350mm Each 11329.00 13910.00 16133.00
(vii) Cast Iron Plain ended Crosses Class 15 Class 20 Class 25
80X80mm Each 875.00 989.00 1147.00
100X100mm Each 1240.00 1542.00 1778.00
125X125mm Each 1764.00 2165.00 2495.00
150X150mm Each 2588.00 3169.00 3621.00
200X200mm Each 4639.00 5693.00 6525.00
250X250mm Each 6876.00 8461.00 9464.00
300X300mm Each 10253.00 12619.00 14125.00
350X350mm Each 13910.00 16993.00 19789.00
(viii) Cast Iron Plain ended Reducers Class 15 Class 20 Class 25
100X80mm Each 602.00 717.00 817.00
125X80mm Each 710.00 846.00 968.00
125X100mm Each 789.00 968.00 1111.00
150X80mm Each 868.00 1040.00 1190.00
150X100mm Each 946.00 1169.00 1341.00

80
Item Items Unit Rate in Rupees
No.
150X125mm Each 1054.00 1291.00 1491.00
200X100mm Each 1305.00 1613.00 1879.00
200X125mm Each 1405.00 1735.00 2029.00
200X150mm Each 1570.00 1936.00 2259.00
250X125mm Each 1706.00 2137.00 2459.00
250X150mm Each 1871.00 2323.00 2689.00
250X200mm Each 2223.00 2768.00 3227.00
300X150mm Each 2330.00 2911.00 3406.00
300X200mm Each 2689.00 3356.00 3951.00
300X250mm Each 2976.00 3585.00 4359.00
350X200mm Each 4223.00 5184.00 5987.00
350X250mm Each 4675.00 5750.00 6611.00
350X300mm Each 5299.00 6525.00 7529.00
(ix) Cast Iron Adopter (Flange Spigot) Class 15 Class 20 Class 25
(T.P.)
80mm Each 531.00 566.00 609.00
100mm Each 652.00 731.00 789.00
125mm Each 839.00 932.00 1054.00
150mm Each 1097.00 1226.00 1341.00
200 mm Each 1628.00 1850.00 2058.00
250 mm Each 2639.00 3033.00 3284.00
300mm Each 3427.00 3965.00 4352.00
350mm Each 4266.00 4933.00 5557.00
(x) Cast Iron Blank end cap Class 15 Class 20 Class 25
(Dead end cap)
80mm Each 244.00 265.00 315.00
100mm Each 351.00 423.00 509.00
125mm Each 488.00 581.00 710.00
150mm Each 731.00 868.00 1047.00
200mm Each 1334.00 1606.00 1950.00
250mm Each 1893.00 2273.00 2710.00
300mm Each 2803.00 3363.00 4044.00
350mm Each 3678.00 4402.00 5205.00
5.9 Labour for laying in position including
testing following cast iron plain ended
standard specials confirming to
IS/5531/1988 (Reaffirmed 2002)
(i) Cast Iron Plain ended 90° Bend Class 15 Class 20 Class 25
80mm Each 16.00 18.00 21.00
100mm Each 22.00 27.00 31.00
125mm Each 31.00 38.00 43.00
150mm Each 44.00 54.00 61.00
200mm Each 77.00 94.00 106.00
250mm Each 112.00 137.00 152.00

81
Item Items Unit Rate in Rupees
No.
300mm Each 164.00 201.00 222.00
350 mm Each 220.00 269.00 313.00
(ii) Cast Iron Plain ended 45° Bend Class 15 Class 20 Class 25
80mm Each 16.00 18.00 21.00
100mm Each 22.00 27.00 30.00
125mm Each 29.00 36.00 41.00
150mm Each 41.00 50.00 57.00
200mm Each 68.00 84.00 96.00
250mm Each 96.00 119.00 133.00
300mm Each 137.00 169.00 192.00
350mm Each 178.00 220.00 258.00
(iii) Cast Iron Plain ended 22½° Bend Class 15 Class 20 Class 25
80mm Each 12.00 14.00 16.00
100mm Each 16.00 20.00 24.00
125mm Each 21.00 27.00 31.00
150mm Each 30.00 37.00 44.00
200mm Each 50.00 63.00 75.00
250mm Each 69.00 86.00 101.00
300mm Each 97.00 123.00 145.00
350mm Each 124.00 156.00 189.00
(iv) Cast Iron Plain ended 11¼° Bend Class 15 Class 20 Class 25
80mm Each 10.00 11.00 13.00
100mm Each 13.00 17.00 20.00
125mm Each 17.00 22.00 27.00
150mm Each 25.00 31.00 38.00
200mm Each 41.00 52.00 65.00
250mm Each 55.00 70.00 85.00
300mm Each 78.00 100.00 122.00
350mm Each 97.00 124.00 153.00
(v) Cast Iron Plain ended Tees
Body & Branch Class 15 Class 20 Class 25
80x80mm Each 20.00 23.00 27.00
100x80mm Each 26.00 30.00 34.00
100x100mm Each 29.00 36.00 41.00
125X80mm Each 34.00 40.00 45.00
125X100mm Each 37.00 47.00 53.00
125X125mm Each 42.00 51.00 58.00
150x80mm Each 51.00 61.00 69.00
150x100mm Each 53.00 65.00 73.00
150X125mm Each 56.00 69.00 78.00
150x150mm Each 61.00 75.00 85.00
200X80 mm Each 87.00 106.00 119.00
200X100 mm Each 89.00 110.00 123.00
200X125mm Each 93.00 113.00 128.00

82
Item Items Unit Rate in Rupees
No.
200X150 mm Each 99.00 120.00 135.00
200X200 mm Each 109.00 134.00 153.00
250X80 mm Each 128.00 136.00 172.00
250X100 mm Each 131.00 160.00 177.00
250X125mm Each 135.00 165.00 182.00
250X150 mm Each 140.00 171.00 189.00
250X200 mm Each 152.00 186.00 207.00
250X250 mm Each 163.00 201.00 222.00
(vi) Cast Iron Plain ended Tees
Body & Branch Class 15 Class 20 Class 25
300X80mm Each 189.00 231.00 254.00
300X100mm Each 192.00 235.00 258.00
300X125mm Each 195.00 239.00 264.00
300X150mm Each 199.00 243.00 269.00
300X200mm Each 214.00 262.00 290.00
300X250mm Each 227.00 277.00 298.00
300X300mm Each 243.00 300.00 334.00
350X200mm Each 283.00 346.00 401.00
350X250mm Each 296.00 361.00 420.00
350X300mm Each 315.00 384.00 447.00
350X350mm Each 332.00 407.00 472.00
(vii) Cast Iron Plain ended Crosses Class 15 Class 20 Class 25
80X80mm Each 26.00 29.00 34.00
100X100mm Each 36.00 45.00 52.00
125X125mm Each 52.00 63.00 73.00
150X150mm Each 76.00 93.00 106.00
200X200mm Each 136.00 167.00 191.00
250X250mm Each 201.00 248.00 277.00
300X300mm Each 300.00 369.00 413.00
350X350mm Each 407.00 497.00 579.00
(viii) Cast Iron Plain ended Reducers Class 15 Class 20 Class 25
100X80mm Each 18.00 21.00 24.00
125X80mm Each 21.00 25.00 28.00
125X100mm Each 23.00 28.00 33.00
150X80mm Each 25.00 30.00 35.00
150X100mm Each 28.00 34.00 39.00
150X125mm Each 31.00 38.00 44.00
200X100mm Each 38.00 47.00 55.00
200X125mm Each 41.00 51.00 59.00
200X150mm Each 46.00 57.00 66.00
250X125mm Each 50.00 63.00 72.00
250X150mm Each 55.00 68.00 79.00
250X200mm Each 65.00 81.00 94.00
300X150mm Each 68.00 85.00 100.00

83
Item Items Unit Rate in Rupees
No.
300X200mm Each 79.00 98.00 116.00
300X250mm Each 87.00 105.00 128.00
350X200mm Each 124.00 152.00 175.00
350X250mm Each 137.00 168.00 194.00
350X300mm Each 155.00 194.00 220.00
(ix) Cast Iron Adopter (Flange Spigot) (T.P.) Class 15 Class 20 Class 25
80mm Each 16.00 17.00 18.00
100mm Each 19.00 21.00 23.00
125mm Each 25.00 27.00 31.00
150mm Each 32.00 36.00 39.00
200mm Each 48.00 54.00 60.00
250 mm Each 77.00 89.00 96.00
300mm Each 100.00 116.00 127.00
350mm Each 125.00 144.00 163.00
(x) Cast Iron Blank end cap(Dead end cap) Class 15 Class 20 Class 25
80mm Each 7.00 8.00 9.00
100mm Each 10.00 12.00 15.00
125mm Each 14.00 17.00 21.00
150mm Each 21.00 25.00 31.00
200mm Each 39.00 47.00 57.00
250mm Each 5.00 67.00 79.00
300mm Each 82.00 98.00 118.00
350mm Each 108.00 129.00 152.00
5.10 Labour for laying in position Cast Iron
Plain Ended Specials all sizes of any
class which does not appear in this
U.S.O.R.
80mm to 350mm dia Quinta 210.00 210.00 210.00
l

84
CHAPTER – VI

GALVANISED IRON PIPES,


GUN METAL / BRASS VALVES AND
FITTINGS

85
Chapter – VI
GALVANISED IRON PIPES, SPECIALS AND GUN METAL
OR BRASS FITTINGS

NOTES:

1. The G.I. pipes shall be confirming to IS - 1239:2004 (Part II)


2. The hot dip Zinc coating on M.S. tubes shall be confirming to IS - 4736: 1986
3. The Copper alloy Gate valves, Globe wheel valves, Check valves shall be
confirming to IS - 778: 1984 (Reaffirmed 2005)
4. The ferrules for water service connection shall be confirming to IS - 8794:1988
5. All measurement shall be of the finished work.
6. Work shall be executed in accordance with the Indian Standards Specifications
and special notes if any, covered in the agreement of the work.
7. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

GALVANISED IRON PIPES, SPECIALS AND GUN METAL OR


BRASS FITTINGS

Item ITEMS Unit Rate in Rupees


No.

6.1 Providing laying and jointing of


following galvanized Iron (MS)
Pipes with specials (such as
bends, elbows, tees etc) class
light, medium & heavy including
testing of joints, cost of pipes,
specials and jointing materials all
complete. Pipes and sockets
conforming to IS-1239/2011 Part-
II
Light Medium Heavy
15mm dia R Mtr. 84.00 106.00 125.00
20mm dia R Mtr. 118.00 134.00 159.00
25mm dia R Mtr. 169.00 204.00 245.00
32mm dia R Mtr. 207.00 250.00 303.00
40mm dia R Mtr. 269.00 296.00 360.00

86
Item ITEMS Unit Rate in Rupees
No.
50mm dia R Mtr. 330.00 402.00 490.00
65mm dia R Mtr. 473.00 531.00 647.00
80mm dia R Mtr. 541.00 665.00 783.00
100mm dia R Mtr. 793.00 982.00 1157.00
125mm dia R Mtr. - 1283.00 1438.00
150mm dia R Mtr. - 1433.00 1607.00
6.2 Labour for laying and jointing of
following galvanized Iron (MS)
pipes with specials (such as
bends, elbows, tees etc) class
light, medium & heavy including
testing of joints and cost of
jointing materials but excluding
cost of pipes & specials.
Light Medium Heavy
15mm dia R Mtr. 10.00 11.00 12.00
20mm dia R Mtr. 11.00 12.00 13.00
25mm dia R Mtr. 16.00 17.00 19.00
32mm dia R Mtr. 17.00 18.00 20.00
40mm dia R Mtr. 21.00 24.00 26.00
50mm dia R Mtr. 23.00 26.00 29.00
65mm dia R Mtr. 39.00 43.00 47.00
80mm dia R Mtr. 41.00 46.00 51.00
100mm dia R Mtr. 61.00 68.00 75.00
125mm dia R Mtr. -. 88.00 96.00
150mm dia R Mtr. - 105.00 115.00
6.3 Providing and fixing following
gate (full way) valves tested to
300lbs/Sq inch or 21.00 kg/sq.cm.
confirming to IS 778/1984
(Reaffirmed 2005) Class-I
Screwed Flanged
15mm dia Each 416.00 541.00
20mm dia Each 537.00 698.00
25mm dia Each 885.00 1151.00
32mm dia Each 1287.00 1673.00
40mm dia Each 1653.00 2149.00
50mm dia Each 2483.00 3228.00
65mm dia Each 4566.00 5936.00
80mm dia Each 6382.00 8297.00
100mm dia Each 12066.00 15686.00
6.4 Providing and fixing following
gate (full way) valves tested to
300lbs/Sq inch or 21.00 kg/sq.cm.

87
Item ITEMS Unit Rate in Rupees
No.
confirming to IS 778/1984
(Reaffirmed 2005) Class-II
Screwed Flanged
15mm dia Each 519.00 674.00
20mm dia Each 661.00 860.00
25mm dia Each 1099.00 1428.00
32mm dia Each 1606.00 2088.00
40mm dia Each 1963.00 2552.00
50mm dia Each 3113.00 4047.00
65mm dia Each 5678.00 7381.00
80mm dia Each 7827.00 10175.00
100mm dia Each 14464.00 18803.00
6.5 Providing and fixing following
class-I Globe wheel valves,
confirming to IS 778/1984
(Reaffirmed 2005), tested to
21.09 kg/sq.cmt.
Screwed Flanged
15mm dia Each 378.00 491.00
20mm dia Each 549.00 714.00
25mm dia Each 851.00 1106.00
32mm dia Each 1382.00 1797.00
40mm dia Each 1891.00 2458.00
50mm dia Each 2593.00 3371.00
65mm dia Each 5009.00 6511.00
80mm dia Each 6650.00 8645.00
100mm dia Each 11355.00 14762.00
6.6 Providing and fixing following
class-II Globe wheel valves,
confirming to IS 778/1984
(Reaffirmed 2005), tested to
21.09 kg/sq.cmt.
Screwed Flanged
15mm dia Each 467.00 607.00
20mm dia Each 662.00 861.00
25mm dia Each 1053.00 1369.00
32mm dia Each 1722.00 2238.00
40mm dia Each 2350.00 3055.00
50mm dia Each 3284.00 4270.00
65mm dia Each 5824.00 7571.00
80mm dia Each 7567.00 9837.00
100mm dia Each 13602.00 17683.00

88
Item ITEMS Unit Rate in Rupees
No.
6.7 Providing and fixing following
check (non-return) valves Class-
I, confirming to IS-778/1984
(Reaffirmed 2005) female ends,
tested to 21.09 kg/sq.cmt.
Screwed Flanged
15mm dia Each 378.00 491.00
20mm dia Each 549.00 714.00
25mm dia Each 851.00 1106.00
32mm dia Each 1382.00 1797.00
40mm dia Each 1891.00 2458.00
50mm dia Each 2593.00 3371.00
65mm dia Each 5009.00 6511.00
80mm dia Each 6650.00 8645.00
100mm dia Each 11355.00 14762.00
6.8 Providing and fixing following
check (non-return) valves Class-
II, confirming to IS-778/1984
(Reaffirmed 2005) female ends,
tested to 21.09 kg/sq.cmt.

Screwed Flanged
15mm dia Each 453.00 588.00
20mm dia Each 659.00 856.00
25mm dia Each 1021.00 1327.00
32mm dia Each 1658.00 2156.00
40mm dia Each 2268.00 2949.00
50mm dia Each 3112.00 4045.00
65mm dia Each 6011.00 7814.00
80mm dia Each 7980.00 10375.00
100mm dia Each 13626.00 17714.00
6.9 Providing and fixing following
GM or brass ferrules confirming
to IS-2692/1989 (Reaffirmed
2005), tested to 21.09 kg/sq.cm.
i/c boring and tapping the main
Screwed
15mm dia Each 495.00
20mm dia Each 712.00
25mm dia Each 1869.00
6.10 Labour for laying, fixing
including testing and carriage of
Screwed or flanged Gate valves
(full way) Class-I

89
Item ITEMS Unit Rate in Rupees
No.
Screwed Flanged
15mm dia Each 15.00 19.00
20mm dia Each 19.00 25.00
25mm dia Each 32.00 41.00
32mm dia Each 46.00 60.00
40mm dia Each 59.00 77.00
50mm dia Each 89.00 115.00
65mm dia Each 163.00 212.00
80mm dia Each 228.00 297.00
100mm dia Each 431.00 561.00
6.11 Labour for laying, fixing and
including testing carriage of
Screwed or flanged Gate valves
(full way) Class-II
Screwed Flanged
15mm dia Each 19.00 24.00
20mm dia Each 24.00 31.00
25mm dia Each 39.00 51.00
32mm dia Each 57.00 75.00
40mm dia Each 70.00 91.00
50mm dia Each 111.00 145.00
65mm dia Each 203.00 264.00
80mm dia Each 280.00 364.00
100mm dia Each 517.00 672.00
6.12 Labour for laying, fixing and
including testing carriage of
Screwed or flanged globe wheel
valves Class-I
Screwed Flanged
15mm dia Each 14.00 18.00
20mm dia Each 20.00 26.00
25mm dia Each 30.00 40.00
32mm dia Each 49.00 64.00
40mm dia Each 68.00 88.00
50mm dia Each 93.00 121.00
65mm dia Each 179.00 233.00
80mm dia Each 238.00 309.00
100mm dia Each 406.00 528.00
6.13 Labour for laying, fixing and
including testing carriage of
Screwed or flanged globe wheel
valves Class-II
Screwed Flanged
15mm dia Each 17.00 22.00

90
Item ITEMS Unit Rate in Rupees
No.
20mm dia Each 24.00 31.00
25mm dia Each 38.00 49.00
32mm dia Each 62.00 80.00
40mm dia Each 84.00 109.00
50mm dia Each 117.00 153.00
65mm dia Each 208.00 271.00
80mm dia Each 271.00 352.00
100mm dia Each 486.00 632.00

6.14 Labour for laying, fixing and


including testing carriage of
Screwed or flanged check (non-
return) valves Class-I,
15mm dia Each 14.00 18.00
20mm dia Each 20.00 26.00
25mm dia Each 30.00 40.00
32mm dia Each 49.00 64.00
40mm dia Each 68.00 88.00
50mm dia Each 93.00 121.00
65mm dia Each 179.00 233.00
80mm dia Each 238.00 309.00
100mm dia Each 406.00 528.00

6.15 Labour for laying, fixing and


including testing carriage of
Screwed or flanged check (non-
return) valves Class-II,
Screwed Flanged
15mm dia Each 16.00 21.00
20mm dia Each 24.00 31.00
25mm dia Each 37.00 47.00
32mm dia Each 59.00 77.00
40mm dia Each 81.00 105.00
50mm dia Each 111.00 145.00
65mm dia Each 215.00 279.00
80mm dia Each 285.00 371.00
100mm dia Each 487.00 633.00
6.16 Labour for laying, fixing and
including testing carriage of
following GM or brass ferrules
Screwed
15mm dia Each 132.00
20mm dia Each 191.00
25mm dia Each 500.00

91
Item ITEMS Unit Rate in Rupees
No.
6.17 Providing & fixing including
testing water taps Brass
Stainless CI self
Heavy
Steel closing
Duty
15mm dia Each 195.00 250.00 364.00
20mm dia Each 250.00 310.00 490.00
6.18 Labour for fixing including
testing and carriage of water Brass
Stainless CI self
taps Heavy
Steel closing
Duty
15mm dia Each 8.00 10.00 13.00
20mm dia Each 10.00 12.00 18.00
6.19 Providing and fixing Screwed
Ball valves tested to 21.09 kg/cm
confirming to IS 778/1984
15mm dia Each 406.00
20mm dia Each 559.00
25mm dia Each 870.00
32mm dia Each 1485.00
40mm dia Each 2108.00
50mm dia Each 3104.00
65mm dia Each 6574.00
80mm dia Each 11300.00
100mm dia Each 17559.00
6.20 Labour only for fixing and
carriage of Ball valves tested to
21 kg/cm confirming to IS
778/1984
15mm dia Each 15.00
20mm dia Each 20.00
25mm dia Each 31.00
32mm dia Each 53.00
40mm dia Each 75.00
50mm dia Each 111.00
65mm dia Each 235.00
80mm dia Each 404.00
100mm dia Each 628.00
6.21 Providing and fixing G. I. Union in
G.I. Pipe line i/c cutting threading
testing etc. complete (New work)
confirming to IS 1879
15mm dia Each 107.00
20mm dia Each 184.00
25mm dia Each 238.00
32mm dia Each 313.00

92
Item ITEMS Unit Rate in Rupees
No.
40mm dia Each 425.00
50mm dia Each 550.00
65mm dia Each 876.00
80mm dia Each 1332.00
100mm dia Each 2075.00
6.22 Labour for fixing G. I. Union in
G.I. Pipe line i/c cutting
threading, testing and carriage of
etc. complete (New work)
15mm dia Each 13.00
20mm dia Each 22.00
25mm dia Each 29.00
32mm dia Each 38.00
40mm dia Each 52.00
50mm dia Each 67.00
65mm dia Each 107.00
80mm dia Each 162.00
100mm dia Each 252.00
6.23 Providing and fixing G. I. Union
in G.I. Pipe line i/c cutting
threading testing etc. complete
(Old work) confirming to IS 1879
15mm dia Each 130.00
20mm dia Each 223.00
25mm dia Each 289.00
32mm dia Each 379.00
40mm dia Each 515.00
50mm dia Each 666.00
65mm dia Each 1062.00
80mm dia Each 1614.00
100mm dia Each 2515.00
6.24 Labour for fixing G. I. Union in
G.I. Pipe line i/c cutting
threading, testing and carriage
etc. complete (Old work)
15mm dia Each 35.00
20mm dia Each 60.00
25mm dia Each 77.00
32mm dia Each 101.00
40mm dia Each 138.00
50mm dia Each 178.00
65mm dia Each 284.00
80mm dia Each 432.00
100mm dia Each 673.00

93
Item ITEMS Unit Rate in Rupees
No.
6.25 Providing and fixing G. I. socket
in G.I. Pipe line i/c cutting
threading testing etc. complete
(Old work) confirming to IS 1879
15mm dia Each 22.00
20mm dia Each 33.00
25mm dia Each 45.00
32mm dia Each 67.00
40mm dia Each 82.00
50mm dia Each 138.00
65mm dia Each 180.00
80mm dia Each 268.00
100mm dia Each 446.00
125mm dia Each 603.00
150mm dia Each 704.00
6.26 Labour only for fixing G.I. socket
in G.I. Pipe line i/c cutting
threading, testing and carriage of
etc. complete .
(Old work)
15mm dia Each 6.00
20mm dia Each 9.00
25mm dia Each 12.00
32mm dia Each 18.00
40mm dia Each 22.00
50mm dia Each 37.00
65mm dia Each 48.00
80mm dia Each 72.00
100mm dia Each 119.00
125mm dia Each 161.00
150mm dia Each 188.00
Providing and fixing G. I. Bend
6.27 90 degree in G.I. Pipe line i/c
cutting threading testing etc.
complete (Old work) confirming
to IS 1879
15mm dia Each 45.00
20mm dia Each 65.00
25mm dia Each 111.00
32mm dia Each 189.00
40mm dia Each 225.00
50mm dia Each 345.00
65mm dia Each 428.00
80mm dia Each
505.00
94
Item ITEMS Unit Rate in Rupees
No.
100mm dia Each 1453.00
125mm dia Each 1652.00
150mm dia Each 2011.00
6.28 Labour only for fixing G. I. Bend
90 degree in G.I. Pipe line i/c
cutting threading, testing and
carriage etc. complete (Old work) .
15mm dia Each 12.00
20mm dia Each 17.00
25mm dia Each 30.00
32mm dia Each 50.00
40mm dia Each 60.00
50mm dia Each 92.00
65mm dia Each 114.00
80mm dia Each 135.00
100mm dia Each 389.00
125mm dia Each 442.00
150mm dia Each 538.00
6.29 Providing and fixing G. I. Tee in
G.I. Pipe line i/c cutting
threading testing etc. complete
(Old work) confirming to IS 1879
15mm dia Each 69.00
20mm dia Each 113.00
25mm dia Each 155.00
32mm dia Each 263.00
40mm dia Each 342.00
50mm dia Each 561.00
65mm dia Each 964.00
80mm dia Each 1234.00
100mm dia Each 2289.00
6.30 Labour only for fixing G. I. Tee
in G.I. Pipe line i/c cutting
threading, testing and carriage
etc. complete (Old work)
15mm dia Each 18.00
20mm dia Each 30.00
25mm dia Each 41.00
32mm dia Each 70.00
40mm dia Each 91.00
50mm dia Each 150.00
65mm dia Each 258.00
80mm dia Each 330.00
100mm dia Each 612.00

95
Item ITEMS Unit Rate in Rupees
No.
6.31 Providing and fixing G. I.
Elbow in G.I. Pipe line i/c
cutting threading testing etc.
complete (Old work)
confirming to IS 1879
15mm dia Each 48.00
20mm dia Each 83.00
25mm dia Each 114.00
32mm dia Each 187.00
40mm dia Each 235.00
50mm dia Each 442.00
65mm dia Each 693.00
80mm dia Each 935.00
100mm dia Each 1818.00
6.32 Labour only for fixing G. I.
Elbwo in G.I. Pipe line i/c cutting
threading testing etc. complete
(Old work)

15mm dia Each 13.00


20mm dia Each 22.00
25mm dia Each 30.00
32mm dia Each 50.00
40mm dia Each 63.00
50mm dia Each 118.00
65mm dia Each 186.00
80mm dia Each 250.00
100mm dia Each 487.00
6.33 Providing and fixing G. I.
Nipple of minimum length in
G.I. Pipe line i/c cutting,
threading, testing and carriage
etc. complete (Old work)
confirming to IS 1879
15mm dia Each 30.00
20mm dia Each 46.00
25mm dia Each 67.00
32mm dia Each 113.00
40mm dia Each 139.00
50mm dia Each 207.00
65mm dia Each 382.00
80mm dia Each 564.00
100mm dia Each 1054.00

96
Item ITEMS Unit Rate in Rupees
No.
6.34 Labour only for fixing G. I. .
Nipple of minimum length in G.I.
Pipe line i/c cutting threading
testing etc. complete (Old work)
15mm dia Each 8.00
20mm dia Each 12.00
25mm dia Each 18.00
32mm dia Each 30.00
40mm dia Each 37.00
50mm dia Each 55.00
65mm dia Each 102.00
80mm dia Each 151.00
100mm dia Each 282.00
6.35 Providing and fixing G. I. Barrel
Nipple (reducer) in G.I. Pipe line
i/c cutting threading testing etc.
complete (New work) confirming
to IS 1879
15x80mm Each 25.00
15x100mm Each 30.00
20x80mm Each 31.00
20x100mm Each 34.00
25x80mm Each 42.00
25x100mm Each 43.00
32x80mm Each 58.00
32x100mm Each 75.00
40x80mm Each 81.00
40x100mm Each 103.00
50x80mm Each 87.00
50x100mm Each 113.00
50x150mm Each 122.00
65x80mm Each 90.00
65x100mm Each 145.00
65x150mm Each 210.00
80x100mm Each 167.00
80x150mm Each 178.00
100x150mm Each 266.00
80x125mm Each 293.00
100x125mm Each 362.00
125x150mm Each 487.00
6.36 Labour only for fixing G. I. .
Barrel Nipple (reducer)G.I. Pipe
line i/c cutting threading testing
etc. complete (New work)

97
Item ITEMS Unit Rate in Rupees
No.
15x80mm Each 3.00
15x100mm Each 4.00
20x80mm Each 4.00
20x100mm Each 4.00
25x80mm Each 5.00
25x100mm Each 5.00
32x80mm Each 7.00
32x100mm Each 9.00
40x80mm Each 10.00
40x100mm Each 13.00
50x80mm Each 11.00
50x100mm Each 14.00
50x150mm Each 15.00
65x80mm Each 11.00
65x100mm Each 18.00
65x150mm Each 26.00
80x100mm Each 20.00
80x150mm Each 22.00
100x150mm Each 32.00
80x125mm Each 36.00
100x125mm Each 44.00
125x150mm Each 59.00
6.37 Providing and fixing G. I. Barrel
Nipple (reducer) in G.I. Pipe line
i/c cutting threading testing etc.
complete (Old work) confirming
to IS 1879
15x80mm Each 30.00
15x100mm Each 36.00
20x80mm Each 37.00
20x100mm Each 42.00
25x80mm Each 50.00
25x100mm Each 52.00
32x80mm Each 71.00
32x100mm Each 91.00
40x80mm Each 98.00
40x100mm Each 125.00
50x80mm Each 105.00
50x100mm Each 137.00
50x150mm Each 148.00
65x80mm Each 109.00
65x100mm Each 176.00
65x150mm Each 255.00
80x100mm Each 203.00

98
Item ITEMS Unit Rate in Rupees
No.
80x150mm Each 216.00
100x150mm Each 322.00
80x125mm Each 356.00
100x125mm Each 439.00
125x150mm Each 590.00
6.38 Labour only for fixing G. I.
Barrel Nipple (reducer)G.I. Pipe
line i/c cutting threading testing
etc. complete (Old work)
15x80mm Each 8.00
15x100mm Each 10.00
20x80mm Each 10.00
20x100mm Each 11.00
25x80mm Each 13.00
25x100mm Each 14.00
32x80mm Each 19.00
32x100mm Each 24.00
40x80mm Each 26.00
40x100mm Each 34.00
50x80mm Each 28.00
50x100mm Each 37.00
50x150mm Each 40.00
65x80mm Each 29.00
65x100mm Each 47.00
65x150mm Each 68.00
80x100mm Each 54.00
80x150mm Each 58.00
100x150mm Each 86.00
80x125mm Each 95.00
100x125mm Each 117.00
125x150mm Each 158.00
6.39 Providing and fixing G. I.
threaded Flange in G.I. Pipe line
i/c cutting threading testing etc.
complete (New work) confirming
to IS 1879
15mm dia Each 76.00
20mm dia Each 80.00
25mm dia Each 101.00
32mm dia Each 119.00
40mm dia Each 147.00
50mm dia Each 189.00
65mm dia Each 224.00
80mm dia Each 301.00

99
Item ITEMS Unit Rate in Rupees
No.
100mm dia Each 400.00
125mm dia Each 652.00
150mm dia Each 743.00
200mm dia Each 1213.00
6.40 Labour only for fixing G.I.
threaded Flange in G.I. Pipe line
i/c cutting threading, testing and
carriage etc.complete(New work)
15mm dia Each 9.00
20mm dia Each 10.00
25mm dia Each 12.00
32mm dia Each 14.00
40mm dia Each 18.00
50mm dia Each 23.00
65mm dia Each 27.00
80mm dia Each 37.00
100mm dia Each 49.00
125mm dia Each 79.00
150mm dia Each 90.00
200mm dia Each 147.00
6.41 Providing and fixing G. I.
threaded Flange in G.I. Pipe line
i/c cutting threading testing etc.
complete (Old work) confirming
to IS 1879
15mm dia Each 92.00
20mm dia Each 97.00
25mm dia Each 122.00
32mm dia Each 144.00
40mm dia Each 178.00
50mm dia Each 229.00
65mm dia Each 272.00
80mm dia Each 365.00
100mm dia Each 484.00
125mm dia Each 790.00
150mm dia Each 901.00
200mm dia Each 1470.00
6.42 Labour only for fixing G. I.
threaded Flange in G.I. Pipe line
i/c cutting threadingt,testing and
carriage etc. complete (Old work)
15mm dia Each 25.00
20mm dia Each 26.00
25mm dia Each 33.00

100
Item ITEMS Unit Rate in Rupees
No.
32mm dia Each 39.00
40mm dia Each 48.00
50mm dia Each 61.00
65mm dia Each 73.00
80mm dia Each 98.00
100mm dia Each 130.00
125mm dia Each 211.00
150mm dia Each 241.00
200mm dia Each 393.00
6.43 Providing and fixing wrought
steel Plug in G.I. Pipe line with
outer threading testing etc.
complete (New & Old work)
confirming to IS 1879
15mm dia Each 20.00
20mm dia Each 27.00
25mm dia Each 44.00
32mm dia Each 73.00
40mm dia Each 104.00
50mm dia Each 160.00
65mm dia Each 206.00
80mm dia Each 258.00
100mm dia Each 459.00
6.44 Labour only for fixing wrought
steel Plug in G.I. Pipe line with
outer threading, testing and
carriage etc. complete. (Old
Work)
15mm dia Each 5.00
20mm dia Each 7.00
25mm dia Each 12.00
32mm dia Each + 20.00
40mm dia Each 28.00
50mm dia Each 43.00
65mm dia Each 55.00
80mm dia Each 69.00
100mm dia Each 123.00
6.45 Providing and fixing wrought
steel Cap Plug with threading in
G.I. Pipe line testing etc.
complete confirming ti IS:1879
(New & Old Work)
15mm dia Each 39.00
20mm dia Each 57.00

101
Item ITEMS Unit Rate in Rupees
No.
25mm dia Each 90.00
32mm dia Each 128.00
40mm dia Each 168.00
50mm dia Each 235.00
65mm dia Each 299.00
80mm dia Each 483.00
100mm dia Each 829.00
6.46 Labour only for fixing
wrought steel Cap Plug with
threading in G.I. Pipe line,
testing and carriage etc.
complete (Old work)
15mm dia Each 10.00
20mm dia Each 15.00
25mm dia Each 24.00
32mm dia Each 34.00
40mm dia Each 45.00
50mm dia Each 63.00
65mm dia Each 80.00
80mm dia Each 129.00
100mm dia Each 222.00
6.47 Providing and fixing G. I.
Cross with outer threading in
G.I. Pipe line i/c cutting
threading testing etc. complete
(Old work)
15mm dia Each 109.00
20mm dia Each 144.00
25mm dia Each 214.00
32mm dia Each 338.00
40mm dia Each 428.00
50mm dia Each 676.00
6.48 Labour only for fixing G. I.
cross outer threading in G.I.
Pipe line i/c cutting, threading,
testing and carriage etc.
complete (Old work)
15mm dia Each 29.00
20mm dia Each 39.00
25mm dia Each 57.00
32mm dia Each 90.00
40mm dia Each 115.00
50mm dia Each 181.00

102
Item ITEMS Unit Rate in Rupees
No.
6.49 Providing and fixing Tank Nipple
with outer threading in G.I. Pipe
line i/c cutting threading testing etc.
complete confirming to IS 1879

15mm dia Each 81.00


20mm dia Each 112.00
25mm dia Each 188.00
32mm dia Each 268.00
40mm dia Each 352.00
50mm dia Each 558.00
6.50 Labour only for Tank Nipple
with outer threading in G.I. Pipe
line i/c cutting, threading, testing
and carriage etc. complete

15mm dia Each 10.00


20mm dia Each 14.00
25mm dia Each 23.00
32mm dia Each 33.00
40mm dia Each 43.00
50mm dia Each 68.00

103
CHAPTER – VII

P.V.C. PIPES & FITTINGS

104
Chapter – VII
P.V.C. PIPES & FITTINGS
NOTES:
1. The Unplasticized P.V.C. pipes shall be confirming to IS - 4985:2000
2. The laying and jointing of UPVC pipes shall be done as per IS - 4736: 1986
3. The injection mould PVC fitting with solvent cement joint shall be confirming to
IS - 7834: 1975 (Part I to VIII)
4. All measurements shall be of the finished work.
5. Work shall be executed in accordance with the Indian Standards Specifications
and special notes if any, covered in the agreement of the work.
6. This USOR contains the rates of all the items without GST. GST shall be paid
separately as per prevailing government norms as claimed by the contractor
in his bill.
All the estimates based on this USOR will include GST as an extra amount as
per prevailing rates on the sum of the estimate to arrive at the gross amount.

P.V.C. PIPES & FITTINGS

S.No. Items Unit Rates in RS.


7.1 Providing, laying and jointing
following P.V.C. pipes with
solvent cement joint for 6, 8
and 10 kg/ sq. cm. pressures
including testing of joints,
cost of jointing materials etc. 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
complete in all respect.
90 mm dia. R. mtr. 156.00 226.00 257.00
110 mm dia. R. mtr. 217.00 307.00 351.00
140 mm dia. R. mtr. 362.00 516.00 570.00
160 mm dia. R. mtr. 463.00 655.00 738.00
180 mm dia. R. mtr. 603.00 870.00 954.00
200 mm dia. R. mtr. 814.00 1120.00 1297.00
7.2 Labour for laying in position
including testing following PVC
pipes of 6, 8 and 10Kg/Sqcm.
pressure. 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
90 mm dia. R. mtr. 4.00 4.00 4.00
110 mm dia. R. mtr. 5.00 5.00 5.00
140 mm dia. R. mtr. 6.00 6.00 6.00
160 mm dia. R. mtr. 7.00 7.00 7.00
180 mm dia. R. mtr. 9.00 9.00 9.00

105
S.No. Items Unit Rates in RS.
200 mm dia. R. mtr. 12.00 12.00 12.00
7.3 Providing, Solvent Cement
Joints to PVC Pipes and
fittings of 6, 8 and 10 Kg/Sq
cm. Pressure including
testing of joints and cost of
jointing materials (i.e. socket,
coupler & solvent cement) 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2

90 mm dia. Each 24.00 24.00 24.00


110 mm dia. Each 27.00 27.00 27.00
140 mm dia. Each 33.00 33.00 33.00
160 mm dia. Each 39.00 39.00 39.00
180 mm dia. Each 42.00 42.00 42.00
200 mm dia. Each 58.00 58.00 58.00
7.4 Labour for providing solvent
cement joints to PVC pipes
and fittings of 6, 8 and 10Kg
/Sq cm. Pressure including
testing of joints but excluding
cost of jointing materials (i.e.
coupler and solvent cement) 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2

90 mm dia. Each
Joint 19.00 19.00 19.00
110 mm dia. Each
Joint 20.00 20.00 20.00
140 mm dia. Each
Joint 22.00 22.00 22.00
160 mm dia. Each
Joint 24.00 24.00 24.00
180 mm dia. Each
Joint 26.00 26.00 26.00
200 mm dia. Each
Joint 32.00 32.00 320.00
7.5 Providing and laying in
position including testing
following PVC bends suitable
for 6, 8 and 10 Kg/Sq. cm. 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
pressure pipes.

90 mm dia. Each 153.00 202.00 250.00


110 mm dia. Each 248.00 336.00 398.00
140 mm dia. Each 592.00 814.00 942.00
160 mm dia. Each 788.00 1110.00 1322.00
180 mm dia. Each 1190.00 1513.00 1816.00
200 mm dia. Each 1470.00 1943.00 2348.00

106
S.No. Items Unit Rates in RS.
7.6 Providing and laying in
position including testing
following PVC Tees, suitable
for 6, 8 and 10 Kg/Sqm. 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
Pressure pipes.
90 mm dia. Each 91.00 112.00 127.00
110 mm dia. Each 120.00 210.00 251.00
140 mm dia. Each 314.00 331.00 348.00
160 mm dia. Each 521.00 547.00 667.00
180 mm dia. Each 645.00 787.00 987.00
200 mm dia. Each 870.00 1146.00 1512.00
7.7 Providing and laying in
position including testing
following PVC flanged tail
pieces suitable for 6, 8 and 10
Kg./Sq. cm. Pressure pipes. 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
90 mm dia. Each 65.00 69.00 74.00
110 mm dia. Each 128.00 137.00 146.00
140 mm dia. Each 204.00 218.00 233.00
160 mm dia. Each 350.00 374.00 401.00
180 mm dia. Each 469.00 501.00 537.00
200 mm dia. Each 621.00 664.00 713.00
7.8 Providing and laying in
position including testing
following PVC end Cap
(plugs) suitable for 6, 8 and 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
10 Kg/Sq cm. Pressure pipes.
90 mm dia. Each 37.00 44.00 58.00
110 mm dia. Each 53.00 63.00 84.00
140 mm dia. Each 83.00 101.00 135.00
160 mm dia. Each 137.00 167.00 226.00
180 mm dia. Each 183.00 224.00 304.00
200 mm dia. Each 221.00 272.00 369.00
7.9 Providing and laying in
position including testing
PVC coupler suitable for 6, 8
6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
and 10 Kg/Sq. cm. Pressure
pipes.
90 mm dia. Each 50.00 60.00 85.00
110 mm dia. Each 79.00 94.00 133.00
140 mm dia. Each 148.00 178.00 277.00
160 mm dia. Each 260.00 315.00 356.00
180 mm dia. Each 364.00 433.00 446.00
200 mm dia Each 469.00 508.00 536.00

107
S.No. Items Unit Rates in RS.
7.10 Providing and laying in
position including testing of
following PVC Reducers
suitable for 6, 8 and 10 Kg/Sq 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
cm. Pressure pipes.

110x90 mm dia. Each 70.00 83.00 99.00


140x90 mm dia. Each 111.00 130.00 141.00
160x90 mm dia. Each 141.00 167.00 243.00
180x90 mm dia. Each 147.00 174.00 258.00
140x110 mm dia. Each 114.00 135.00 158.00
160x110 mm dia. Each 141.00 167.00 245.00
180x110 mm dia. Each 198.00 236.00 265.00
200x110 mm dia. Each 254.00 302.00 351.00
160x140 mm dia. Each 146.00 173.00 207.00
180x140 mm dia. Each 207.00 246.00 286.00
200x140 mm dia Each 342.00 408.00 473.00
180x160 mm dia Each 224.00 266.00 309.00
200x160 mm dia. Each 360.00 430.00 499.00
200x180 mm dia. Each 372.00 444.00 515.00
7.11 Labour for laying in position
including testing all types of
PVC fittings such as bends,
tees, plugs etc. for following 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
PVC pipes.
90 mm dia. Each 7.00 7.00 7.00
110 mm dia. Each 8.00 8.00 8.00
140 mm dia. Each 10.00 10.00 10.00
160 mm dia. Each 12.00 12.00 12.00
180 mm dia. Each 12.00 12.00 12.00
200 mm dia. Each 14.00 14.00 14.00
7.12 Providing and fixing PVC D-
joint ( Detachable joint) in 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
PVC pipe line suitable for
classes up to 10kg/sqcm
Pressure pipes. i/c nut bolt,
cutting of pipe, testing of
joints etc complete.

90 mm dia. Each 110.00 110.00 110.00


110 mm dia. Each 124.00 124.00 124.00
140 mm dia. Each 166.00 166.00 166.00
160 mm dia. Each 193.00 193.00 193.00
180mm dia. Each 228.00 228.00 228.00
200mm dia. Each 331.00 331.00 331.00

108
S.No. Items Unit Rates in RS.
7.13 Labour only for fixing PVC
D-joint ( Detachable joint) in 6Kg/Cm2 8 Kg/Cm2 10Kg/Cm2
PVC pipe line suitable for
classes up to 10kg/sqcm
Pressure pipes. i/c cutting of
pipe, testing of joints etc
complete.
90 mm dia. Each 18.00 18.00 18.00
110 mm dia. Each 20.00 20.00 20.00
140 mm dia. Each 26.00 26.00 26.00
160 mm dia. Each 31.00 31.00 31.00
180mm dia. Each 36.00 36.00 36.00
200mm dia. Each 53.00 53.00 53.00

109
CHAPTER – VIII

CAST IRON VALVES

110
Chapter – VIII
CAST IRON VALVES
NOTES:
1. The Sluice Valves (50-1000 mm size) shall be confirming to IS -14846:2000
2. The resilient seated C.I. Air relief valve shall be confirming to IS - 14845:
2000
3. The Swing check type reflux valves shall be confirming to IS - 5312: 2004
(Part I & II )
4. The Butter fly valves shall be conforming to IS - 13095:1991
5. All measurement shall be of the finished work.
6. Work shall be executed in accordance with the Indian Standards Specifications
and special notes if any, covered in the agreement of the work.
7. This USOR contains the rates of all the items without GST and the GST shall
be paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

CAST IRON VALVES

S.No. Items Unit Rates in Rupees


8.1 Providing & fixing of following Cast PN-1.0 PN-1.6
iron double flanged sluice valves as per
I.S.:14846-2000 fitted with cast iron cap
including jointing & testing with cost of
jointing material such as bolts, nuts,
rubber insertions etc. all complete
50mm dia Each 2432.00 2610.00
65mm dia Each 2870.00 3085.00
80mm dia Each 3397.00 3647.00
100mm dia Each 4671.00 5006.00
125mm dia Each 5678.00 6101.00
150mm dia Each 6933.00 7434.00
200mm dia Each 12068.00 12965.00
250mm dia Each 17742.00 18896.00
300mm dia Each 22207.00 23670.00

111
S.No. Items Unit Rates in Rupees
8.2 Fixing of following Cast iron double PN-1.0
flanged sluice valves fitted with cast iron
cap testing with cost of jointing material
such as bolts, nuts, rubber insertions etc.
all complete (only valve to be supplied by
deptt. free of cost.
50mm dia Each 208.00
65mm dia Each 215.00
80mm dia Each 225.00
100mm dia Each 352.00
125mm dia Each 384.00
150mm dia Each 511.00
200mm dia Each 706.00
250mm dia Each 1141.00
300mm dia Each 1290.00
350 mm dia Each 2128.00
400 mm dia Each 3267.00
450 mm dia Each 3953.00
500 mm dia Each 4990.00
600 mm dia Each 7230.00
700 mm dia Each 8603.00
750 mm dia Each 9251.00
800 mm dia Each 12176.00
900 mm dia Each 13778.00
1000 mm dia Each 17489.00
Labour for laying and fixing of
8.3 following cast iron double flanged sluice
valves (vide item no.1) including
jointing and testing but without cost of
Jointing materials.
50mm dia Each 76.00
65mm dia Each 95.00
80mm dia Each 107.00
100mm dia Each 148.00
125mm dia Each 174.00
150mm dia Each 216.00
200mm dia Each 323.00
250mm dia Each 464.00
300mm dia Each 599.00
350mm dia Each 1046.00
400mm dia Each 1237.00
450mm dia Each 1479.00
500mm dia Each 1790.00
600mm dia Each 2723.00
700mm dia Each 3123.00

112
S.No. Items Unit Rates in Rupees
750mm dia Each 3243.00
800mm dia Each 3684.00
8.4a Providing & fixing following cast iron CLASS-
double flanged single door reflux (non PN- 1.0
return) valves including jointing &
testing with cost of jointing material
such as bolts,nuts and rubber insertion
all complete as per IS :5312 (Part I)
50mm dia Each 1873.00
65mm dia Each 2347.00
80mm dia Each 2923.00
100mm dia Each 3745.00
150mm dia Each 6481.00
200mm dia Each 12582.00
250mm dia Each 18758.00
300mm dia Each 24286.00
350mm dia Each 42082.00
8.4b Providing & fixing following cast iron
double flanged multi door reflux (non CLASS CLASS PN-
return) valves including jointing & PN- 1.0 1.60
testing with cost of jointing material
such as bolts,nuts and rubber insertion
all complete as per IS : 5312 (Part II)

400mm dia Each 50419.00 59609.00


450mm dia Each 59233.00 85230.00
500mm dia Each 105694.00 159546.00
600mm dia Each 145494.00 199172.00
700mm dia Each 165868.00 251499.00
750mm dia Each 243391.00 292609.00
800mm dia Each 276660.00 334562.00
8.5 Labour for laying and fixing of
following Cast Iron Double Flanged
reflux (non return) valves including
jointing & testing but without cost of
jointing materials

50mm dia Each 60.00


65mm dia Each 75.00
80mm dia Each 86.00
100mm dia Each 118.00
125mm dia Each 136.00
150mm dia Each 166.00
200mm dia Each 206.00
250mm dia Each 337.00

113
S.No. Items Unit Rates in Rupees
300mm dia Each 428.00
350mm dia Each 657.00
400mm dia Each 856.00
450mm dia Each 964.00
500mm dia Each 1203.00
600mm dia Each 1829.00
700mm dia Each 2099.00
750mm dia Each 2179.00
800mm dia Each 2476.00
8.6 Providing & fixing following cast iron CLASS CLASS PN-
butterfly valves including jointing & PN- 1.0 1.6
testing with cost of jointing material
such as bolts,nuts and rubber insertion
all complete as per IS :13095-1991

50mm dia Each 1534.00 1610.00


65mm dia Each 1756.00 1844.00
80mm dia Each 2009.00 2109.00
100mm dia Each 2675.00 2808.00
150mm dia Each 3407.00 3577.00
200mm dia Each 6524.00 6850.00
250mm dia Each 10930.00 11476.00
300mm dia Each 14919.00 15664.00
8.7 Labour for laying and fixing of
following Cast Iron butterfly valves
including jointing & testing but without
cost of jointing materials

50mm dia Each 60.00


65mm dia Each 75.00
80mm dia Each 86.00
100mm dia Each 118.00
150mm dia Each 136.00
200mm dia Each 166.00
250mm dia Each 206.00
300mm dia Each 337.00
8.8 Providing & fixing following cast iron CLASS CLASS PN-
single air valves, small orifice with PN- 1.0 1.6
screwed end as per IS: 14845-2000
including jointing & testing with cost of
jointing material and rubber insertion
all complete as per IS :13095-1991

25mm dia Each 2864.00 3007.00


40mm dia Each 3036.00 3188.00

114
S.No. Items Unit Rates in Rupees
8.9 Labour for laying and fixing of
following Cast Iron Air valves small
orifice with screwed end i/c jointing &
testing but without cost of jointing
material.
25mm dia Each 25
40mm dia Each 33
8.10 Providing & fixing following cast iron CLASS CLASS PN-
single acting air valves, large orifice PN- 1.0 1.6
with screwed end as per IS : 14845-2000
including jointing & testing with cost of
jointing material and rubber insertion
all complete as per IS :13095-1991
25mm dia Each 2864.00 3007.00
40mm dia Each 3036.00 3188.00
50mm dia Each 3523.00 3699.00
8.11 Labour for laying and fixing of
following Cast Iron Air valves large
orifice with screwed end i/c jointing &
testing but without cost of jointing
material. .
25mm dia Each 25.00
40mm dia Each 33.00
50mm dia Each 60.00
8.12 Providing & fixing following cast iron CLASS CLASS PN-
double acting air valves, flanged PN- 1.0 1.6
without inbuilt isolating valve as per IS
: 14845-2000 including jointing &
testing with cost of jointing material
and rubber insertion all complete as per
IS :13095-1991
40mm dia Each 3254.00 3416.00
50mm dia Each 3853.00 4045.00
65mm dia Each 4066.00 4269.00
80mm dia Each 5673.00 5956.00
100mm dia Each 8874.00 9317.00
150mm dia Each 16412.00 17233.00
200mm dia Each 27973.00 29372.00
8.13 Labour for laying and fixing including
testing following Cast Iron double
acting air valves, flanged without in-
built isolating valve.
40mm dia Each 33.00
50mm dia Each 60.00
65mm dia Each 75.00
80mm dia Each 86.00
115
S.No. Items Unit Rates in Rupees
100mm dia Each 118.00
150mm dia Each 136.00
200mm dia Each 166.00
8.14 Providing & fixing following cast iron
double acting air valves, flanged with
inbuilt isolating valve as per IS : 14845- CLASS CLASS PN-
2000 including jointing & testing with PN- 1.0 1.6
cost of jointing material and rubber
insertion all complete as per IS :13095-
1991
40mm dia Each 3576.00 3755.00
80mm dia Each 6232.00 6543.00
100mm dia Each 9751.00 10239.00
150mm dia Each 18040.00 18942.00
200mm dia Each 28813.00 30253.00
8.15 Labour for laying and fixing, including
testing following Cast Iron double
acting air valves, flanged with in-built
isolating valve.
40mm dia Each 33.00
80mm dia Each 60.00
100mm dia Each 118.00
150mm dia Each 136.00
200mm dia Each 166.00

116
CHAPTER IX

HDPE PIPE, MDPE PIPE


(POLYETHYLENE PIPES FOR WATER SUPPLY)
& SPECIALS

117
CHAPTER IX
HDPE PIPE, MDPE PIPE & SPECIALS

NOTES:

1. This specification covers the requirements for successfully designing,


manufacturing, supplying, laying, jointing and testing at works and site of High
Density Polyethylene Pipes used for water supply. Use of HDPE Pipes shall be
of pressure class of minimum PN 6 or above.

2. Applicable Codes
The manufacturing, testing, supplying, laying, jointing and testing at work
sites of HDPE pipes shall comply with IS: 4984-2016 all currently applicable
statutes, regulations, standards and amendments and others as follows-

Code no. Title / Specification


IS 4984 High Density Polyethylene Pipes renamed as PE (Polyethylene
Pipes) for Water Supply
IS 2530 Methods of test for polyethylene molding materials and polyethylene
compounds GRP Pipes, Joints and Fittings for use for Potable Water
Supply
IS 5382 Rubber sealing rings for gas mains, water mains and sewers.
IS 4905 Methods for random sampling
IS 7328 High density polyethylene materials for molding and extrusion
IS 7634 Laying & Jointing of Polyethylene (PE) Pipes
IS 9845 Method of analysis for the determination of specific and/or overall
migration of constituents of plastics material and articles intended to
come into contact with foodstuffs
IS 10141 Positive list of constituents of polyethylene in contact with food
stuffs, pharmaceuticals and drinking water.
IS 10146 Polyethylene for its safe use in contact with foodstuff,
Pharmaceuticals and drinking water.

3. Color
The color of the pipe shall be black.

4. Materials
The material used for the manufacturer of pipes should not constitute toxicity
hazard, should not support microbial growth, should not give rise to
unpleasant taste or odour, cloudiness or discoloration of water. Pipe
manufacturers shall obtain a certificate to this effect from the manufacturers
of raw material by any internationally reputed organization as per the
satisfaction of the Engineer-in-Charge in charge.

118
5. Raw Material
(a) Resin used to manufacture the HDPE pipes shall be 100% virgin PE Black
pre-compounded confirming to IS: 4984, IS: 7328 and ISO: 4427-2007
(latest version). The resin proposed to be used for manufacturing of the pipes
should also comply with the following norms as per ISO 9080-2003 (latest
version).
(b) The resin should also have been certified by an independent laboratory of
international repute like Bodycote/Slevan/Advantica for having passed 10,000
hour long term hydrostatic strength (LTHS) test extrapolated to 50 years to
show that the resin has a minimum MRS of over 10MPa. There should not be
any brittle knee at 80OC before 5000 hours. Internal certificate of any resin
manufacturer will not be acceptable.
(c) Certificate from reputed organization OR Raw material supplier for having
passed the full scale rapid crack propagation test as per ISO 13478. High
density Polyethylene (HDPE) used for the manufacture of pipes shall conform
to designation PEEWA-50-T-003 of IS 7328. HDPE conforming to
designation PEEWA-50- T-003 of IS: 7328 may also be used. Melt Flow Rate
(MFR) of the specific base density material shall also conform to clause of IS:
7328.
(d) The resin shall be compounded wit carbon black. The carbon black content in
the material shall be within 2.5±0.5% and the dispersion of carbon black shall
be satisfactory when tested as per IS: 2530.
6. Anti-oxidant
The percentage of anti-oxidant used shall not be more than 0.3 percent by
mass of finished resin. The anti-oxidant used shall be physiologically harm
less and shall be selected from the list given in IS: 10141
7. Reworked Material
No addition of Reworked/ Recycled Material from the manufacturer’s own
rework material resulting from the manufacture of pipes is permissible and
the vendor is required to use only 100% virgin resin compound.
8. Maximum Ovality of Pipe
The outside diameter of pipes, tolerance on the same and ovality of pipe shall
be as given in table 2 of IS 4984.
9. Detectability
HDPE Pipes shall be detectable when buried underground, by providing an
insulated copper wire having minimum diameter of 1.20 mm, firmly attached
along the entire length of pipe.
To avoid theft or dislocation during handling / laying or earth refilling in
trench, the insulated Copper wire shall be firmly fixed on the outer surface of
HDPE pipe at Pipe manufacturer’s works through external adhesion or co-
extrusion or any other appropriate method.
10. Length of Straight Pipe
The length of straight pipe used shall be more than 6 m or as agreed by
Engineer-in-Charge in charge. Short lengths of 3 meter (minimum) up to a
maximum of 10% of the total supply may be permitted.
11. Coiling
The pipes supplied in coils shall be coiled on drums of minimum diameter of

119
25 times the nominal diameter of the pipe ensuring that kinking of pipe is
prevented. Pipe beyond 110mm dia shall be supplied in straight length not less
than 6m.
12. Fittings & Specials
All HDPE fittings/ specials shall be of minimum PN 6 or above Pressure
class, fabricated in accordance with IS: 8360 (Part I & III). PE Injection
molded fittings shall be as per IS: 8008
(Part I to IX). All fittings/specials shall be fabricated or molded at factory
only. No
fabrication or molding will be allowed at site, unless specifically permitted by
the Engineer-in-Charge. Fittings will be welded on to the pipes or other
fittings by use of Electro- fusion process. Recommended makes for PE /
Compression fittings / specials are Kimplas, Georg-Fischer, Glynwed,
Trustlene, Astore, Magnum and GPS.
13. Bends
HDPE bends shall be plain square ended conforming to IS: 8360 Part I & III
Specifications.
Bends shall be molded.
14. Tees
HDPE Tees shall be plain square ended conforming to IS: 8360 Part I & II
Specifications.
Tees may be equal tees or reduced take off tees. Tees shall be molded.
15. Reducers
HDPE Reducers shall be plain square ended conforming to IS: 8008 Part I &
VII
Specifications. Reducer must be molded.
16. Flanged HDPE Pipe Ends
HDPE Stub ends shall be square ended conforming to IS: 8008 Part I & VI
Specifications. Stub ends will be welded on the pipe. Flange will be of slip on
flange type as described below.
17. Slip-On Flanges
Slip-on flanges shall be metallic flanges covered by epoxy coating or plastic
powder coating. Slip-on-flanges shall be conforming to standard mating
relevant flange of valves, pipes etc. Nominal pressure rating of flanges will be
PN10.

18. Electro Fusion Tapping Saddle, Branch Saddle & Electro Fusion
fittings:

a. All the Electro fusion fittings should be manufactured with top quality
virgin pre-compounded PE 100 resin which should be compatible with
the distribution mains.
b. The products shall comply with the requirements o f EN 12201-3, EN
1555-3 or ISO 8085-3.
c. All the fittings shall be of SDR 11 rating.
d. The fittings shall have the approval from any three Agencies like
KIWA, DVGW, WRC-NSF, U.K. CIPET etc.

120
e. All the products shall be manufactured by injection molding
using virgin compounded PE 100 polymer having a melt flow rate
between 0.2- 1.4 grams/10 minutes and shall be compatible for
fusing on PE 100 distribution mains manufactured according to
the relevant national or international standards. The polymer used
should comply with the requirements of EN 12201 -1.
f. Process voltage of all saddles must not exceed a maximum of 40 volts.

19. Compression Fitting-


Compression fitting used for House service connection should comply as
per ISO 14236 with Threaded metal inserts –SS 304 with BSP Threads
Pressure Testing-
The Pressure rating of compression fittings should be as per clause 8 of ISO
14236 which shall be PN 16
Dimensions-
The Dimension of compression fittings shall be as per clause 7.1of ISO
14236 Performed.
 Leak tightness under internal pressure.
 Leak tightness under internal Vacuum.
 Long term Pressure Test for Leak tightness for assembled joint
 MRS Value as per ISO 9080
 Resistance to Internal Pressure.
Effects on Quality of Water-
The Compression fitting for intended for conveyance of Potable
water for Human consumption to be tested to comply with BS 6920
specifications in any of the laboratories like DVGW/ KIWA/ SPGN/
WRC –NSF and certificate of compliance to be produced for the
following parameters:
a. Odor & Flavor of Water.
b. Appearance of Water.
c. Growth of Micro Organism.
d. Extraction of Metals.
e.
All fittings with threaded ends should be with BSP threads.

20. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

121
HDPE PIPE (NOW RENAMED AS POLYETHYLENE PIPES)
MDPE PIPE & SPECIALS
S.No. Items Unit Rates in Rs.
9.1 Providing, Laying, Jointing & field
testing of HDPE pipes (High Density
Polyethylene Pipes) confirming to IS
4984/14151/12786/13488 with necessary
jointing material like mechanical
connector of jointing pipes by heating
to the ends of pipes with the help of
Teflon coated electric mirror/ heater to
the required temperature and then
pressing the ends together against each
other, to form a monolithic & leak
proof joint by thermosetting process. It
may be required to be done with Jack/
Hydraulic Jacks/ Butt fusion machine.
(50 mm & above fusion jointed &
below 50mm mechanical jointed)
Pressure 6Kg/ 8Kg/ 10 Kg/
sq.cm : sq.cm : sq.cm:
63 mm dia R. mtr. 114.00 140.00 173.00
75 mm dia R. mtr. 164.00 201.00 246.00
90 mm dia R. mtr. 232.00 282.00 353.00
110 mm dia R. mtr. 388.00 426.00 518.00
125 mm dia R. mtr. 451.00 546.00 668.00
140 mm dia R. mtr. 563.00 686.00 837.00
160 mm dia R. mtr. 753.00 900.00 1097.00
180 mm dia R. mtr. 930.00 1129.00 1389.00
200 mm dia R. mtr. 1151.00 1395.00 1708.00
225 mm dia R. mtr. 1456.00 1765.00 2171.00
250 mm dia R. mtr. 1795.00 2173.00 2668.00
280 mm dia R. mtr. 2240.00 2731.00 3349.00
315 mm dia R. mtr. 2825.00 3460.00 4238.00
9.2 Providing and laying including testing
Bend 90̊ confirming to IS
specifications.
Pressure 6Kg/ 8Kg/ 10 Kg/
sq.cm : sq.cm : sq.cm:
63 mm dia Each 83.00 89.00 124.00
75 mm dia Each 129.00 133.00 159.00
90 mm dia Each 199.00 213.00 255.00
110 mm dia Each 264.00 308.00 345.00
125 mm dia Each 379.00 457.00 579.00
140 mm dia Each 514.00 641.00 792.00
160 mm dia Each 737.00 926.00 1152.00
180 mm dia Each 1018.00 1288.00 1614.00
200 mm dia Each 1364.00 1733.00 2180.00
122
S.No. Items Unit Rates in Rs.
9.3 Providing and laying including testing
Bend 45̊ confirming to IS
specification.
Pressure 6Kg/ 8Kg/ 10 Kg/
sq.cm : sq.cm : sq.cm:
63 mm dia Each 96.00 96.00 126.00
75 mm dia Each 146.00 146.00 193.00
90 mm dia Each 210.00 210.00 285.00
110 mm dia Each 312.00 359.00 452.00
125 mm dia Each 434.00 526.00 665.00
140 mm dia Each 633.00 738.00 951.00
160 mm dia Each 913.00 1122.00 1366.00
180 mm dia Each 1235.00 1364.00 1873.00
200 mm dia Each 1627.00 1758.00 2482.00
9.4 Providing and laying including testing
Equal Tee confirming to IS
specification
Pressure 6Kg/ 8Kg/ 10Kg/
sq.cm : sq.cm : sq.cm:
PN 6 PN 8 PN 10
63 mm dia Each 102.00 113.00 125.00
75 mm dia Each 169.00 176.00 216.00
90 mm dia Each 300.00 305.00 369.00
110 mm dia Each 439.00 453.00 530.00
125 mm dia Each 485.00 607.00 718.00
140 mm dia Each 663.00 830.00 984.00
160 mm dia Each 957.00 1207.00 1439.00
180 mm dia Each 1330.00 1686.00 2024.00
200 mm dia Each 1791.00 2281.00 2746.00
9.5 Providing and laying including testing
Pipe end confirming to IS specification.
Pressure 6Kg/ 8Kg/ 10Kg/
sq.cm : sq.cm : sq.cm:
PN 6 PN 8 PN 10
63 mm dia Each 74.00 76.00 78.00
75 mm dia Each 95.00 103.00 103.00
90 mm dia Each 138.00 155.00 155.00
110 mm dia Each 175.00 207.00 207.00
125 mm dia Each 272.00 308.00 308.00
140 mm dia Each 342.00 389.00 389.00
160 mm dia Each 348.00 409.00 409.00
180 mm dia Each 538.00 615.00 615.00
200 mm dia Each 573.00 635.00 657.00

123
S.No. Items Unit Rates in Rs.
9.6 Providing and laying including testing
Reducer: confirming to IS
specifications.

Pressure 6Kg/sq. 8Kg/sq.cm 10Kg/sq.c


cm : : m:
PN 6 PN 8 PN 10
63 mm dia Each 91.00 92.00 95.00
75 mm dia Each 116.00 118.00 124.00
90 mm dia Each 125.00 131.00 138.00
110 mm dia Each 127.00 153.00 163.00
125 mm dia Each 133.00 178.00 182.00
140 mm dia Each 158.00 196.00 202.00
160 mm dia Each 206.00 256.00 285.00
180 mm dia Each 242.00 327.00 363.00
200 mm dia Each 279.00 381.00 406.00
9.7 Providing butt fusion welded
joint/joining by heating to the ends
with the help of Teflon coated electric
mirror/heater ends together etc. by
thermosetting processes to HDPE Pipe
and specials. (6 kg. 8 kg. 10 kg.) (50
mm & above fusion jointed & below 50
mm mechanical jointed) including
testing
63 mm dia Each 105.00
75 mm dia Each 132.00
90 mm dia Each 146.00
110 mm dia Each 161.00
125 mm dia Each 194.00
140 mm dia Each 206.00
160 mm dia Each 223.00
180 mm dia Each 235.00
200 mm dia Each 250.00
9.8 Providing and laying including testing
End Cap confirming to IS
specifications.
Pressure 6Kg/ 8Kg/ 10 Kg/
sq.cm : sq.cm : sq.cm:
63 mm dia Each 75.00 76.00 80.00
75 mm dia Each 93.00 98.00 102.00
90 mm dia Each 105.00 106.00 113.00
110 mm dia Each 110.00 110.00 116.00

124
S.No. Items Unit Rates in Rs.
125 mm dia Each 132.00 182.00 185.00
140 mm dia Each 190.00 216.00 222.00
160 mm dia Each 226.00 315.00 328.00
180 mm dia Each 325.00 379.00 395.00
200 mm dia Each 388.00 453.00 472.00
9.9 Providing and Supplying Blue MDPE
pipes conforming to ISO 4427:1996
manufactured from virgin resin PE 80
Food grade compounded Raw Material
having Blue Colour only with quality
assurance certificate from quality
agencies like WRC/CIPET (India)/
DVGM /KIWA /SPGN etc. for usage in
Drinking Water System The cost shall
include testing of all materials,
Inspection charges, transportation up
to site, transit insurance, loading,
unloading, stacking etc. complete.
PN 16 (SDR 9) 6Kg/ 8Kg/ 10 Kg/
sq.cm : sq.cm : sq.cm:
20 mm dia R. mtr 36.00
25 mm dia R. mtr 50.00
32 mm dia R. mtr 83.00
40 mm dia R. mtr 108.00
50 mm dia R. mtr 164.00
9.10 Providing & Supply of Electro Fusion
Tapping Ferrule (Branch Tapping
Saddle) female BSP Threaded with SS
304 insert fittings in accordance with
BS EN 12201 : Part-3 suitable for
drinking water with in black/ blue
colour manufactured from
compounded PE80/PE100 pipes, in
pressure rating SDR 11 with min PN
12.5 rated . The cost such as testing,
inspection charges, transportation up
to site, transit insurance, loading,
unloading, stacking etc. complete.
9.10.1 Electo Fusion Tapping Ferrule Saddle
9.10.1 63x15mm Each 999.00
9.10.2 63x20mm Each 999.00
9.10.3 63x25mm Each 999.00
9.10.4 75x15mm Each 999.00
9.10.5 75x20mm Each 999.00
9.10.6 75x25mm Each 999.00

125
S.No. Items Unit Rates in Rs.
9.10.7 90x15mm Each 999.00
9.10.8 90x20mm Each 999.00
9.10.9 90x25mm Each 999.00
9.10.10 90x32mm Each 1296.00
9.10.11 90X40mm Each 1296.00
9.10.12 90X50mm Each 1296.00
9.10.13 110X15mm Each 999.00
9.10.14 110X20mm Each 999.00
9.10.15 110X25mm Each 999.00
9.10.16 110X32mm Each 1296.00
9.10.17 110x40mm Each 1296.00
9.10.18 110x50mm Each 1296.00
9.10.19 160x15mm Each 999.00
9.10.20 160x20mm Each 999.00
9.10.21 160x25mm Each 999.00
9.10.22 160x32mm Each 1416.00
9.10.23 160x40mm Each 1416.00
9.10.24 160x50mm Each 1416.00
9.10.25 200x15mm Each 1410.00
9.10.26 200x20mm Each 1410.00
9.10.27 200x25mm Each 1410.00
9.10.28 200x32mm Each 2040.00
9.10.29 200x40mm Each 2040.00
9.10.30 200x50mm Each 2040.00
9.11 Providing & Supply of Compression
fitting, PN 16 rated in conformation to
ISO: 14236-2000 and shall be tested as
per ISO: 3459, ISO: 3501 & ISO: 3503,
suitable for drinking water &
approved by WRAS, UKI KIWA etc.,
in food grade polypropylene and shall
be inclusive of all cost such as testing,
inspection charges, transportation up
to site, transit insurance, loading,
unloading, stacking etc. complete.
9.11.1.1 Compression Fittings Metal inserted
Compression Female
Threaded Adaptor with SS 304
Material
9.11.1.1 20x15mm Each 170.00
9.11.1.2 25x20mm Each 220.00

126
S.No. Items Unit Rates in Rs.
9.11.1.3 32x25mm Each 300.00
9.11.1.4 40x32mm Each 510.00
9.11.1.5 50x40mm Each 660.00
9.11.1.6 63x50mm Each 900.00
Metal inserted Compression Male
9.11..2 Threaded Adaptor with SS 304
Material
9.11.2.1 20x15mm Each 170.00
9.10.2.2 25X20mm Each 220.00
9.11.2.3 32X25mm Each 300.00
9.11.2.4 40X32mm Each 510.00
9.11.2.5 50x40mm Each 660.00
9.11.2.6 63x50mm Each 900.00
9.11.3 Compression 90̊ Elbow threaded male
off take in Metal
9.11.3.1 20x15mm Each 180.00
9.11.3.2 25X20mm Each 240.00
9.11.3.3 32X25mm Each 330.00
9.11.3.4 40X32mm Each 1150.00
9.11.3.5 50x40mm Each 1500.00
9.11.3.6 63x50mm Each 2200.00
9.11.4 Compression 90̊ Elbow threaded
Female off take in Metal
9.11.4.1 20x15mm Each 180.00
9.11.4.2 25X20mm Each 240.00
9.11.4.3 32X25mm Each 330.00
9.11.4.4 40X32mm Each 1150.00
9.11.4.5 50x40mm Each 1500.00
9.11.4.6 63x50mm Each 2200.00
9.11.5 Compression 90 ̊ Elbow
9.11.5.1 20mm Each 110.00
9.11.5.2 25mm Each 150.00
9.11.5.3 32mm Each 195.00
9.11.5.4 40mm Each 390.00
9.11.5.5 50mm Each 554.00
9.11.5.6 63mm Each 751.00
9.12 Providing & Supply of PVC Ball
Valves in PN16 rating with one end
compression using Blue color
compression nut in polypropylene

127
S.No. Items Unit Rates in Rs.
material & other end with female
threads conforming to ISO:4422-4,
certified from WRAS UK/KIWA etc.
suitable for food products & drinking
water, female threads in accordance
with ISO:7/BS/:21/IS: 554 and shall be
inclusive of all cost such as testing,
inspection charges, transportation up
to site, transit insurance, loading,
unloading, stacking etc. complete.
PVC Ball Valve with Compression &
Female Threads.

9.12.1 20x15mm Each 175.00


9.12.2 25X20mm Each 227.00
9.12.3 32X25mm Each 256.00
9.12.4 40X32mm Each 550.00
9.12.5 50x40mm Each 737.00
9.12.6 63x50mm Each 1133.00
9.13 Providing & Supplying of Clamp
Saddle (DI Strap Saddle) for House
Service connections from metal pipe
water distribution mains shall be of
fastened strap type with threaded
outlet for service connection. Clamp
Saddle shall be suitable for nominal
size of distribution mains pipe line. The
strap shall be elastomer coated
(insulated) type for firm grip on pipe as
well as to protect the coating on the
pipe and to insulate the unidentical
metals. The saddle shall be single strap
type up to pipe sizes of NB 600 and
service outlet 15mm, 20mm & 25mm.
Fasteners shall be of threaded nut bolt
washer type. The sealing between the
saddle and mains shall be obtained by
using a profiled elastomer seal
matching to the curvature of the pipe.
The seal shall be of elastomer type,
suitable for all potable water
application. The material of
construction of the body, straps,
fasteners etc. shall be of non-corrosive
material such as engineering plastic
(PE/PP) or stainless steel or a
combination of both. and shall be
inclusive of all cost such as testing,

128
S.No. Items Unit Rates in Rs.
inspection charges, transportation up
to site, transit insurance, loading,
unloading, stacking etc. complete.
9.13.1 80 NB x 15mm, 20mm, 25mm Each 1000.00
9.13.2 100 NB x 15mm, 20mm, 25mm Each 1100.00
9.13.3 150 NB x 15mm, 20mm, 25mm Each 1300.00
9.13.4 200 NB x 15mm, 20mm, 25mm Each 1500.00
9.13.5 250 NB x 15mm, 20mm, 25mm Each 1700.00
9.13.6 300 NB x 15mm, 20mm, 25mm Each 1900.00
9.14 Providing & Supply of Electro Fusion
Fittings in accordance with BS EN
12201 : Part-3 suitable for drinking
water with in black/blue color
manufactured from compounded
PE80/PE100 virgin polymer and
compatible with PE80/PE100 pipes, in
pressure rated SDR 11 with min PN
12.5 rated for water application and
shall be inclusive of all cost such as
testing, inspection charges,
transportation up to site, transit
insurance, loading, unloading, stacking
etc. complete.
9.14.1 Electro Fusion Coupler
9.14.1.1 20mm Each 100.00
9.14.1.2 25mm Each 100.00
9.14.1.3 32mm Each 100.00
9.14.1.4 40mm Each 185.00
9.14.1.5 50mm Each 229.00
9.14.1.6 63mm Each 247.00
9.14.1.7 75mm Each 444.00
9.14.1.8 90mm Each 476.00
9.14.1.9 110mm Each 678.00
9.10.1.10 125mm Each 689.00
9.14.1.11 140mm Each 1478.00
9.14.1.12 160mm Each 1620.00
9.14.1.13 180mm Each 2419.00
9.14.1.14 200mm Each 3158.00
9.14.1.15 225mm Each 3749.00
9.14.1.16 250mm Each 4568.00
9.14.1.17 280mm Each 9153.00

129
S.No. Items Unit Rates in Rs.
9.14.1.18 315mm Each 9186.00
9.14.2 Electro Fusion Equal Tee
9.14.2.1 20mm Each 250.00
9.14.2.2 25mm Each 250.00
9.14.2.3 32mm Each 250.00
9.14.2.4 40mm Each 848.00
9.14.2.5 50mm Each 942.00
9.14.2.6 63mm Each 1050.00
9.14.2.7 75mm Each 1400.00
9.14.2.8 90mm Each 1740.00
9.14.2.9 110mm Each 2100.00
9.14.2.10 125mm Each 2600.00
9.14.2.11 140mm Each 5892.00
9.14.2.12 160mm Each 8600.00
9.14.2.13 180mm Each 11000.00
9.14.2.14 200mm Each 13000.00
9.14.2.15 225mm Each 19000.00
9.14.2.16 250mm Each 21000.00
9.14.2.17 280mm Each 23000.00
9.14.3 Electro Fusion Elbow 90̊
9.14.6.3. 20mm Each 190.00
1
9.14.3.2 25mm Each 190.00
9.14.3.3 32mm Each 190.00
9.14.3.4 40mm Each 500.00
9.14.3.5 50mm Each 500.00
9.14.3.6 63mm Each 500.00
9.14.3.7 75mm Each 1100.00
9.14.3.8 90mm Each 1500.00
9.14.3.9 110mm Each 2000.00
9.14.3.10 125mm Each 2400.00
9.14.3.11 140mm Each 5100.00
9.14.3.12 160mm Each 6600.00
9.14.3.13 180mm Each 8500.00
9.14.3.14 200mm Each 16000.00
9.14.3.15 225mm Each 18000.00
9.14.3.16 250mm Each 20000.00

130
S.No. Items Unit Rates in Rs.
9.14.3.17 280mm Each 22000.00
9.14.3.18 315mm Each 25000.00
9.16.4 Electro Fusion Reducer
9.14.4.1 25x20mm Each 200.00
9.14.4.2 32x20mm Each 200.00
9.14.4.3 32x25mm Each 200.00
9.14.4.4 40x32mm Each 670.00
9.14.4.5 50x32mm Each 840.00
9.14.4.6 50x40mm Each 928.00
9.14.4.7 63x32mm Each 990.00
9.14.4.8 63x40mm Each 1001.00
9.14.4.9 63x50mm Each 1160.00
9.14.4.10 90x63mm Each 1641.00
9.14.4.11 90x75mm Each 2100.00
9.14.4.12 110x75mm Each 2650.00
9.14.4.13 110x90mm Each 3020.00
9.14.4.14 125x90mm Each 3820.00
9.14.4.15 125x110mm Each 3820.00
9.14.4.16 140x90mm Each 4200.00
9.14.4.17 140x110mm Each 4200.00
9.14.4.18 140x125mm Each 4200.00
9.14.4.19 160x110mm Each 5500.00
9.14.4.20 160x125mm Each 5500.00
9.14.4.21 160x140mm Each 5500.00
9.14.4.22 180x125mm Each 6200.00
9.14.4.23 180x140mm Each 6200.00
9.14.4.24 180x160mm Each 6200.00
9.14.4.25 200x160mm Each 7400.00
9.14.4.26 200x180mm Each 7400.00
9.14.4.27 225x160mm Each 9000.00
9.14.4.28 225x180mm Each 9000.00
9.14.4.29 225x200mm Each 9000.00
9.14.4.30 250x160mm Each 11000.00
9.14.4.31 250x200mm Each 11000.00
9.14.4.32 250x225mm Each 11000.00
9.14.5 Electro Fusion End Cap
9.14.5.1 20mm Each 152.00

131
S.No. Items Unit Rates in Rs.
9.14.5.2 25mm Each 152.00
9.14.5.3 32mm Each 152.00
9.14.5..4 40mm Each 330.00
9.14.5.5 50mm Each 400.00
9.14.5.6 63mm Each 580.00
9.14.5.7 75mm Each 870.00
9.14.5.8 90mm Each 1100.00
9.14.5.9 110mm Each 1400.00
9.14.5.10 125mm Each 1700.00
9.14.5.11 140mm Each 2500.00
9.14.5.12 160mm Each 3600.00
9.14.5.13 180mm Each 4400.00
9.14.5.14 200mm Each 5200.00
9.14.5.15 225mm Each 8500.00
9.14.5.16 250mm Each 10000.00
9.14.5.17 280mm Each 11000.00
9.14.5.18 315mm Each 12000.00
9.14.6 Spigot Long Neck Pipe End (Stub End)
for Electro Fusion Joint
9.14.6.1 63mm Each 358.00
9.14.6.2 75mm Each 403.00
9.14.6.3 90mm Each 505.00
9.14.6.4 110mm Each 770.00
9.14.6.5 125mm Each 1213.00
9.14.6.6 140mm Each 1380.00
9.14.6.7 160mm Each 1975.00
9.14.6.8 180mm Each 2663.00
9.14.6.9 200mm Each 3130.00
9.14.6.10 225mm Each 3755.00
9.14.6.11 250mm Each 4313.00
9.14.6.12 280mm Each 4828.00
9.14.6.13 315mm Each 6275.00

132
CHAPTER- X

MILD STEEL PIPES AND SPECIALS

133
CHAPTER – X
MILD STEEL PIPES AND SPECIALS
NOTES :
1. This Specification covers the requirements for manufacturing, supplying, laying,
jointing, testing at worksite of Electrically Welded Steel pipes, internally lined
with cement concrete and externally coated with cement mortar, used for water
supply mains.
2. Applicable Codes
IS : 3589 Seamless/Electrically Welded Steel Pipes for Water, Gas, Sewage
Specification
IS: 5822 Code of Practice for laying of Electrically Welded Steel Pipes for
Water Supply.
IS : 7322 Specification for Specials for Steel Cylinder Reinforced Concrete
Pipes
IS : 432 Mild Steel and Medium Tensile Bars Reinforcement Part I
IS : 432 Specifications for Mild Steel and Medium Tensile Bars and Hard
Drawn Steel Wire (Third Revision) Part II
IS: 2328 Flattening Test for Seamless Pipes
IS : 12269 Specification for 53 Grade Ordinary Portland Cement (OPC)
IS: 6452 Specification for High Alumina Cement for Structural Use (Ist
Revision)
IS : 8112 Specification for Curing of High Strength OPC
IS : 8041 Specifications for Curing of Rapid Hardening Cement
IS : 269 Specifications for Ordinary Portland Cement (OPC)
IS : 455 Specifications for Portland Slag Cement
IS : 1489 Specifications for Portland Pozzolana Cement
IS : 8043 Specifications for Hydrophobic Portland Cement
IS : 3600 Methods of Testing Fusion Welded Joints and Weld Metal in Steel
cylinder pipes with concrete lining and crating (specifications)
Part I
Steel :
2.1. Other I.S. Codes not Specifically mentioned here but pertaining to the use of
Electrically Welded Steel pipes shall form part of these Specifications.
3. The preferred outside Diameter and thickness of the pipes shall be as per the
Table -1 of IS : 1916: 1969
4. Length : The pipes shall be manufactured in lengths of 6m, unless otherwise
specified.
5. Welding : For manufacturing of the site pipes, the welding & testing should
comply with IS: 816.

134
6. Fabrication of specials: Specials such as bends, tapers, tees shall Conform to IS:
7322, Specials shall be fabricated by cutting plates of the specified thickness to
the required shape obtained by developing the form of specials on ground.
7. Measurement:
The net length of pipes as laid or fixed should be measured in running meters
correct to a fraction of the decimal. Specials should be excluded and enumerated
and paid for separately. The portion of the pipe within the collar at the joints shall
not be included in the length of pipe work.
8. Rates
The rates include charges for all tools & plants, required for lifting and laying the
pipes and specials in positions as per approved drawing and specifications.
The rates include provision and use of all coverings etc. to protect the works from
inclement weather etc. and from damages from fall of materials, and other causes.
9. The rates shown in item are exclusive of the cost of any type of coating but
dimensionally suitable for internal epoxy lining. In case of inside cement mortar
lining extra weight of shell shall be adjusted at the rate of Rs. 81.00 (Eighty one
only) per kg according to the following factor.
Extra mass per meter length of pipe = tc x t x 0.01233

Where in tc = Cement mortar coating thickness in mm


t = Shell thickness in mm

10. The estimate rates for pipe using steel plate (shell) thickness other than
mentioned in item shall be adjusted to the rate of Rs. 81.00 per kg for deffered
thickness.
11 This USOR contains the rates of all the items without GST. GST shall be paid
separately as per prevailing government norms as claimed by the contractor
in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.
M.S. PIPES AND SPECIALS

S. No. Item Unit Rate (in Rs.)


10.1 Manufacturing, Supplying at site & laying,
jointing of following M.S. pipes as per IS
specifications, duly testing for usage in Drinking
water inclusive of all materials, inspection
charges, transit insurance, loading/unloading,
FOR site and stacking etc. complete as per
direction of Engineer-in-Charge. (Excluding
protective coating)

135
S. No. Item Unit Rate (in Rs.)
10.1.1 Dia of pipe 100.00 mm (I.D) Thickness of pipe
(i) 4mm RM 671.00
(ii) 6mm RM 1030.00
(iii) 8mm RM 1404.00
10.1.2 Dia of pipe 150.00 mm (I.D) Thickness of pipe
(i) 4mm RM 994.00
(ii) 6mm RM 1515.00
(iii) 8mm RM 2054.00
10.1.3 Dia of pipe 200.00 mm (I.D) Thickness of pipe
(i) 4mm RM 1317.00
(ii) 6mm RM 2001.00
(iii) 8mm RM 2703.00
10.1.4 Dia of pipe 250.00 mm (I.D) Thickness of pipe
(i) 4mm RM 1639.00
(ii) 6mm RM 2486.00
(iii) 8mm RM 3353.00
10.1.5 Dia of pipe 300.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 1962.00
(ii) 6mm RM 2972.00
(iii) 8mm RM 4003.00
10.1.6 Dia of pipe 350.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 2284.00
(ii) 6mm RM 3457.00
(iii) 8mm RM 4652.00
10.1.7 Dia of pipe 400.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 2607.00
(ii) 6mm RM 3943.00
(iii) 8mm RM 5302.00
(iv) 10mm RM 6653.00
10.1.8 Dia of pipe 450.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 2930.00
(ii) 6mm RM 4429.00
(iii) 8mm RM 5951.00
(iv) 10mm RM 7464.00
10.1.9 Dia of pipe 500.00 mm (I.D) Thickness of pipe :
(i) 5mm RM 4054.00
(ii) 6mm RM 4914.00
(iii) 8mm RM 6601.00
(iv) 10mm RM 8276.00
(v) 12mm RM 10021.00
10.1.10 Dia of pipe 550.00 mm (I.D) Thickness of pipe
(i) 5mm RM 4455.00
(ii) 6mm RM 5400.00
(iii) 8mm RM 7251.00
(iv) 10mm RM 9087.00

136
S. No. Item Unit Rate (in Rs.)
(v) 12mm RM 10999.00
10.1.11 Dia of pipe 600.00 mm (I.D) Thickness of pipe :
(i) 6mm RM 5885.00
(ii) 8mm RM 7900.00
(iii) 10mm RM 9897.00
(iv) 12mm RM 11978.00
10.112 Dia of pipe 650.00 mm (I.D) Thickness of pipe
(i) 6mm RM 6371.00
(ii) 8mm RM 8450.00
(iii) 10mm RM 10709.00
(iv) 12mm RM 12956.00
10.1.13 Dia of pipe 700.00 mm (I.D) Thickness of pipe :
(i) 6mm RM 6856.00
(ii) 8mm RM 9199.00
(iii) 10mm RM 11520.00
(iv) 12mm RM 13934.00
(v) 14mm RM 16219.00
10.1.14 Dia of pipe 750.00 mm (I.D) Thickness of pipe :
(i) 7mm RM 8543.00
(ii) 8mm RM 9849.00
(iii) 10mm RM 12331.00
(iv) 12mm RM 14912.00
10.1.15 Dia of pipe 800.00 mm (I.D) Thickness of pipe :
(i) 7mm RM 9107.00
(ii) 8mm RM 10499.00
(iii) 10mm RM 13143.00
(iv) 12mm RM 15891.00
10.1.16 Dia of pipe 850.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 11148.00
(ii) 10mm RM 13954.00
(iii) 12mm RM 16869.00
10.1.17 Dia of pipe 900.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 11798.00
(ii) 10mm RM 14765.00
(iii) 12mm RM 17847.00
10.1.18 Dia of pipe 950.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 12447.00
(ii) 10mm RM 15576.00
(iii) 12mm RM 18825.00
10.1.19 Dia of pipe 1000.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 13097.00
(ii) 10mm RM 16387.00
(iii) 12mm RM 19804.00
10.1.20 Dia of pipe 1050.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 13747.00

137
S. No. Item Unit Rate (in Rs.)
(ii) 10mm RM 17198.00
(iii) 12mm RM 20782.00
10.1.21 Dia of pipe 1100.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 18010.00
(ii) 12mm RM 21761.00
10.1.22 Dia of pipe 1150.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 18821.00
(ii) 12mm RM 22739.00
10.1.23 Dia of pipe 1200.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 19632.00
(ii) 12mm RM 23717.00
10.1.24 Dia of pipe 1250.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 20443.00
(ii) 12mm RM 24695.00
10.1.25 Dia of pipe 1300.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 21254.00
(ii) 12mm RM 25673.00
10.1.26 Dia of pipe 1350.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 22065.00
(ii) 12mm RM 26652.00
10.1.27 Dia of pipe 1400.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 27630.00
(ii) 14mm RM 3491.00
10.1.28 Dia of pipe 1450.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 28608.00
(ii) 14mm RM 33252.00
10.1.29 Dia of pipe 1500.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 29586.00
(ii) 14mm RM 34387.00
10.1.30 Dia of pipe 1550.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 30565.00
(ii) 14mm RM 35523.00
10.1.31 Dia of pipe 1600.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 36658.00
(ii) 16mm RM 41786.00
10.1.32 Dia of pipe 1650.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 37794.00
(ii) 16mm RM 43079.00
(iii) 18mm RM 48377.00
10.1.33 Dia of pipe 1700.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 38929.00
(ii) 16mm RM 44372.00
(iii) 18mm RM 49827.00
10.1.34 Dia of pipe 1750.00 mm (I.D) Thickness of pipe
(i) 14mm RM 40065.00

138
S. No. Item Unit Rate (in Rs.)
(ii) 16mm RM 45664.00
(iii) 18mm RM 51277.00
10.1.35 Dia of pipe 1800.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 41200.00
(ii) 16mm RM 46957.00
(iii) 18mm RM 52727.00
10.1.36 Dia of pipe 1850.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 42336.00
(ii) 16mm RM 48250.00
(iii) 20mm RM 60117.00
10.1.37 Dia of pipe 1900.00 mm (I.D) Thickness of pipe :
(i) 16mm RM 49543.00
(ii) 18mm RM 55627.00
(iii) 20mm RM 61725.00
10.1.38 Dia of pipe 1950.00 mm (I.D) Thickness of pipe :
(i) 16mm RM 50835.00
(ii) 18mm RM 57077.00
(iii) 20mm RM 63332.00
10.1.39 Dia of pipe 2000.00 mm (I.D) Thickness of pipe :
(i) 16mm RM 52128.00
(ii) 18mm RM 58527.00
(iii) 20mm RM 64939.00
FABRICATION OF M.S. PIPE AND
SPECIALS
10.2 Fabrication of M.S. pipes & specials from steel Kg. 73.00
plates as per relevant IS specifications
inclusive of cost of all materials, for any
thickness as per design, inspection charges,
testing, transit insurance, loading/ unloading,
FOR site and stacking etc. complete as per
direction of the Engineer in charge.
fabricating of pipes and specials from steel
plates .
10.3 Labour only for lowering and laying of MS Kg 1.21
pipe and specials as per approved specification
complete as directed by Engineer incharge
10.4 Providing and applying primer and one coat Sqm 33.00
of red oxide externally
10.5 Providing and applying primer and one coat Sqm 71.00
of red oxide of iron paint, internally
Laying of M.S. Pipes and Specials
10.6 Labour Only for lowering & laying of M.S.
Pipes as per approved specification and as
directed by Engineer incharge.
10.6.1 4mm to 8mm thick

139
S. No. Item Unit Rate (in Rs.)
100mm Upto 500mm. dia RM 71.00
Above 500mm. Upto 750mm. dia RM 116.00
Above 750mm. Upto 1050mm. dia RM 160.00
10.6.2 10mm to 12mm thick
400mm Upto 750mm. dia RM 191.00
Above 750mm. Upto 1050mm. dia RM 264.00
Above 1050mm. Upto 1200mm. dia RM 329.00
Above 1200mm. Upto 1550mm. dia RM 394.00
10.6.3 14mm to 20mm thick
Above 700mm. Upto 1000mm. dia RM 314.00
Above 1000mm. Upto 1250mm. dia RM 392.00
Above 1250mm. Upto 1450mm. dia RM 468.00
Above 1450mm. Upto 1750mm. dia RM 554.00
Above 1750mm. Upto 2000mm. dia RM 649.00
10.7 Providing rigid welded joint to the following
MS pipes including testing of joints and cost of
jointing material as per relevant approved
specification complete.
10.7.1 Dia of pipe 250.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 55.00
(ii) 6mm RM 112.00
(iii) 8mm RM 234.00
10.7.2 Dia of pipe 300.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 65.00
(ii) 6mm RM 133.00
(iii) 8mm RM 269.00
10.7.3 Dia of pipe 350.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 76.00
(ii) 6mm RM 155.00
(iii) 8mm RM 322.00
10.7.4 Dia of pipe 400.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 86.00
(ii) 6mm RM 176.00
(iii) 8mm RM 366.00
(iv) 10mm RM 450.00
10.7.5 Dia of pipe 450.00 mm (I.D) Thickness of pipe :
(i) 4mm RM 97.00
(ii) 6mm RM 198.00
(iii) 8mm RM 411.00
(iv) 10mm RM 504.00
10.7.6 Dia of pipe 500.00 mm (I.D) Thickness of pipe :
(i) 5mm RM 108.00
(ii) 6mm RM 219.00
(iii) 8mm RM 455.00
(iv) 10mm RM 558.00

140
S. No. Item Unit Rate (in Rs.)
(v) 12mm RM 1003.00
10.7.7 Dia of pipe 550.00 mm (I.D) Thickness of pipe :
(i) 5mm RM 119.00
(ii) 6mm RM 242.00
(iii) 8mm RM 499.00
(iv) 10mm RM 611.00
(v) 12mm RM 1098.00
10.7.8 Dia of pipe 600.00 mm (I.D) Thickness of pipe :
(i) 6mm RM 263.00
(ii) 8mm RM 543.00
(iii) 10mm RM 665.00
(iv) 12mm RM 1194.00
10.7.9 Dia of pipe 650.00 mm (I.D) Thickness of pipe :
(i) 6mm RM 284.00
(ii) 8mm RM 587.00
(iii) 10mm RM 718.00
(iv) 12mm RM 1289.00
10.7.10 Dia of pipe 700.00 mm (I.D) Thickness of pipe :
(i) 6mm RM 306.00
(ii) 8mm RM 631.00
(iii) 10mm RM 772.00
(iv) 12mm RM 1385.00
(v) 14mm RM 1393.00
10.7.11 Dia of pipe 750.00 mm (I.D) Thickness of pipe :
(i) 7mm RM 328.00
(ii) 8mm RM 675.00
(iii) 10mm RM 825.00
(iv) 12mm RM 1481.00
10.7.12 Dia of pipe 800.00 mm (I.D) Thickness of pipe :
(i) 7mm RM 350.00
(ii) 8mm RM 718.00
(iii) 10mm RM 879.00
(iv) 12mm RM 1681.00
10.7.13 Dia of pipe 850.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 762.00
(ii) 10mm RM 932.00
(iii) 12mm RM 1673.00
10.7.14 Dia of pipe 900.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 806.00
(ii) 10mm RM 986.00
(iii) 12mm RM 1747.00
10.7.15 Dia of pipe 950.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 851.00
(ii) 10mm RM 1040.00
(iii) 12mm RM 1864.00

141
S. No. Item Unit Rate (in Rs.)
10.7.16 Dia of pipe 1000.00 mm (I.D) Thickness of pipe
(i) 8mm RM 895.00
(ii) 10mm RM 1093.00
(iii) 12mm RM 1959.00
10.7.17 Dia of pipe 1050.00 mm (I.D) Thickness of pipe :
(i) 8mm RM 939.00
(ii) 10mm RM 1147.00
(iii) 12mm RM 2055.00
10.7.18 Dia of pipe 1100.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1201.00
(ii) 12mm RM 2150.00
10.7.19 Dia of pipe 1150.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1255.00
(ii) 12mm RM 2246.00
10.7.20 Dia of pipe 1200.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1308.00
(ii) 12mm RM 2342.00
10.7.21 Dia of pipe 1250.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1362.00
(ii) 12mm RM 2437.00
10.7.22 Dia of pipe 1300.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1415.00
(ii) 12mm RM 2533.00
10.7.23 Dia of pipe 1350.00 mm (I.D) Thickness of pipe :
(i) 10mm RM 1469.00
(ii) 12mm RM 2629.00
10.7.24 Dia of pipe 1400.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 2725.00
(ii) 14mm RM 2732.00
10.7.25 Dia of pipe 1450.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 2820.00
(ii) 14mm RM 2828.00
10.7.26 Dia of pipe 1500.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 2916.00
(ii) 14mm RM 2923.00
10.7.27 Dia of pipe 1550.00 mm (I.D) Thickness of pipe :
(i) 12mm RM 3011.00
(ii) 14mm RM 3019.00
10.7.28 Dia of pipe 1600.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 3114.00
(ii) 16mm RM 3123.00
10.7.29 Dia of pipe 1650.00 mm (I.D) Thickness of pipe
(i) 14mm RM 3211.00
(ii) 16mm RM 3218.00
(iii) 18mm RM 3226.00

142
S. No. Item Unit Rate (in Rs.)
10.7.30 Dia of pipe 1700.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 3306.00
(ii) 16mm RM 3314.00
(iii) 18mm RM 3321.00
10.7.31 Dia of pipe 1750.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 3402.00
(ii) 16mm RM 3409.00
(iii) 18mm RM 3417.00
10.7.32 Dia of pipe 1800.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 3498.00
(ii) 16mm RM 3505.00
(iii) 18mm RM 3512.00
10.7.33 Dia of pipe 1850.00 mm (I.D) Thickness of pipe :
(i) 14mm RM 3593.00
(ii) 16mm RM 3600.00
(iii) 20mm RM 3616.00
10.7.34 Dia of pipe 1900.00 mm (I.D) Thickness of pipe :
(i) 16mm RM 3696.00
(ii) 18mm RM 3704.00
(iii) 20mm RM 3712.00
10.7.35 Dia of pipe 1950.00 mm (I.D) Thickness of pipe
(i) 16mm RM 3792.00
(ii) 18mm RM 3800.00
(iii) 20mm RM 3387.00
10.7.36 Dia of pipe 2000.00 mm (I.D) Thickness of pipe :
(i) 16mm RM 3888.00
(ii) 20mm RM 3903.00
10.8 Providing & applying 30 mm thick 1:3 cement Sqm 430.00
mortar coating out side face of M.S pipe as per
relevant IS specification including testing
along with fixing of (100 x3 mm) wire mesh as
per approved specification per Sqmm
10.9 Providing & applying inside 20 mm thick 1:2 Sqm 315.00
cement mortar on inside face of pipe as per
relevant IS specification including testing as
directed by Engineer in Charge
10.10 Providing & applying 400 micron epoxy Sqm 144.00
coating as per relevat IS specification on out
side face of pipe including testing.
10.11 Providing & applying 400 micron food grade Sqm 225.00
epoxy coating on inside face of pipe as per
relevant IS specification including testing.

143
CHAPTER- XI

BAR WRAPPED STEEL CYLINDER PIPES


(BWSC)

144
CHAPTER-XI
BAR WRAPPED STEEL CYLINDER PIPES (BWSC)
NOTES :
1. Scope
This specification covers the requirements for design, manufacturing, testing,
supplying, laying, jointing, welding and testing at works and site of Bar Wrapped
Steel Cylinder (BWSC) Pipes used for water supply mains.

2. Applicable Codes
IS : 226 Specifications for structural Steel (Standard Quality)
IS : 383 Specifications for coarse and fine aggregates from natural sources for
concrete.
IS : 432 Specifications for mild steel and medium tensile steel bar/wires for
concrete reinforcement.
Part 1 Mild Steel and medium tensile steel bar/wires
Part 2 Hard drawn steel wire
IS : 1566 Specifications for Hard Drawn Steel Wire for Concrete
Reinforcement
IS : 2062 Specifications for Steel for General Structural Purposes
IS : 3597 Methods of Test for Concrete Pipes
IS : 3658 Code of Practice for liquid penetrant flaw detection
IS : 5822 Code of Practice for laying of Electrically Welded Steel Pipes for
Water Supply
IS : 7322 Specifications for Specials for Steel Cylinder Reinforced Concrete
pipes
IS: 15155 Specifications for Bar Wrapped steel Cylinder Pipes (including
Fittings)
AWWA Manual M-9 Concrete pressure pipe
EN 641 Reinforced Concrete Pressure Pipe, Cylinder Type, including Joints
& fittings.
2.1. Other I.S. Codes not Specifically mentioned here but pertaining to the use of
BWSC pipes form part of these Specifications.
3. Design Criteria
3.1. The reinforcement of the pipe shall consist of a welded steel cylinder and bar/wire
is directly wrapped under low tension. The average circumferential stress in the
steel cylinder and bar/wire reinforcement of the pipe shall be as given below:
3.1.1 At factory test pressure, stress shall not exceed 187 N/mm2 nor 75 percent of the
minimum yield strength of the steel used in the cylinder.

145
3.1.2 At site test pressure, stress shall neither exceed 165 N/mm2 nor 75 percent of the
minimum yield strength of the steel used in the cylinder.
3.1.3 At working pressure, stress shall not exceed 125 N/mm2 nor 50 percent of the
minimum yield strength of the steel used in the cylinder.
4. Preparing Pipe faces for Welding: Before aligning, assembling and welding, the
pipe faces shall be cleaned by scrapping by wire brushes or any other method
specified by the authority.
5. Welding : Generally the welding of pipe in the field should comply with IS 816:
1969.
5.1 For field welding rates applicable for similar welding in M.S. Pipes, shall be
adopted.
6. Internal Diameter : The internal diameter shall be measured at each end of the
pipe at approximately 50mm from the ends. Two measurements of the internal
diameter at 90º to each other shall be made at each end and centre. The internal
diameter shall be maintained within the tolerance specified.
7. Wall Thickness : Measurement of outside circumference of the pipe shall be
made at three positions and average outside diameter of the pipe shall be
calculated. The inside diameter shall be measured at three positions and average
shall be calculated.
8. Specials and Fittings
8.1 . The steel for fabricated steel plate specials, in cut, shaped and welded so that
finished special has the required shape and internal dimensions. Adjacent
segments are jointed by butt welding. Before lining and coating the welding of
special shall be tested by use of hot oil or dye penetrant according to IS 3658 and
defects, if any shall be rectified. The steel plate thickness for specials shall be as
given in IS 7322.
8.2 . All the specials shall be tested for hydrostatic pressure as specified for BWSC
pipes and to the pressure specified for pipes in the reaches where the specials are
fitted.
9. For lowering, laying & pouring of cement mortar in the field on joints (after
laying & welding) rate as per P.S.C. pipes Lowering, laying & jointing shall be
adopted.
10. When ever manufacturer is separate and contractor for lowering, laying, jointing
& testing are different, the principal contractor shall enter in to the agreement
with BWSC pipe manufacturer for satisfactory manufacturing, transporting,
lowering, laying, jointing and testing of pipe.

146
11. Measurement:
The net length of pipes as laid or fixed shall be measured in running meters
correct to a cm. Specials shall be excluded and measured and paid separately
under the relevant item. The portion of the pipe at the joints (inside the joints)
shall not be included in the length of pipe work. Excavation, refilling, masonry
and concrete work wherever required shall be measured and paid for separately
under relevant items of work.
12. Rates
The rate shall include the cost of materials and labour involved in all the
operations except for the items measured/enumerated separately under clause
'Measurements', which shall be paid for separately.
13. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing norms as claimed by the contractor in his
bill. All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.

BAR WRAPPED STEEL CYLINDER PIPES (BWSC)


Sr.No. Item Unit Rate (In Rs.)
11.1. Providing Bar Wrapped Steel Cylinder
Pipes test Presure 4 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.

350 mm RM 2360.00
400 mm RM 2696.00
450 mm RM 3120.00
500 mm RM 3473.00
600 mm RM 4622.00
700 mm RM 5429.00
800 mm RM 6204.00
900 mm RM 7844.00
1000 mm RM 9054.00
1100 mm RM 13221.00
1200 mm RM 14668.00
1300 mm RM 16056.00
1400 mm RM 17863.00
1500 mm RM 20687.00
1600 mm RM 22028.00

147
Sr.No. Item Unit Rate (In Rs.)
11.2. Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
4 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 480.00
400 mm RM 552.00
450 mm RM 631.00
500 mm RM 752.00
600 mm RM 850.00
700 mm RM 1001.00
800 mm RM 1147.00
900 mm RM 1449.00
1000 mm RM 1459.00
1100 mm RM 2081.00
1200 mm RM 2315.00
1300 mm RM 2457.00
1400 mm RM 2150.00
1500 mm RM 2317.00
1600 mm RM 2651.00
11.3 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 6 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2364.00
400 mm RM 2700.00
450 mm RM 2124.00
500 mm RM 3481.00
600 mm RM 4629.00
700 mm RM 5444.00
800 mm RM 6212.00
900 mm RM 7852.00
1000 mm RM 9067.00
1100 mm RM 13229.00
1200 mm RM 14680.00
1300 mm RM 16065.00
1400 mm RM 17875.00
1500 mm RM 20703.00
1600 mm RM 22048.00

148
Sr.No. Item Unit Rate (In Rs.)
11.4 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure 6
Kg/Sqcm including testing & cost of jointing
material as per relevant IS specification.
350 mm RM 481.00
400 mm RM 554.00
450 mm RM 634.00
500 mm RM 755.00
600 mm RM 854.00
700 mm RM 1004.00
800 mm RM 1150.00
900 mm RM 1451.00
1000 mm RM 1463.00
1100 mm RM 2082.00
1200 mm RM 2317.00
1300 mm RM 2459.00
1400 mm RM 2151.00
1500 mm RM 2319.00
1600 mm RM 2653.00
11.5 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 8 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2367.00
400 mm RM 2708.00
450 mm RM 3129.00
500 mm RM 3491.00
600 mm RM 4635.00
700 mm RM 5461.00
800 mm RM 6222.00
900 mm RM 7857.00
1000 mm RM 9080.00
1100 mm RM 13241.00
1200 mm RM 14697.00
1300 mm RM 16074.00
1400 mm RM 17891.00
1500 mm RM 20721.00
1600 mm RM 22063.00

149
Sr.No. Item Unit Rate (In Rs.)
11.6 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
8 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 481.00
400 mm RM 558.00
450 mm RM 638.00
500 mm RM 759.00
600 mm RM 859.00
700 mm RM 1008.00
800 mm RM 1153.00
900 mm RM 1452.00
1000 mm RM 1466.00
1100 mm RM 2084.00
1200 mm RM 2320.00
1300 mm RM 2463.00
1400 mm RM 2153.00
1500 mm RM 2322.00
1600 mm RM 2656.00
11.7 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 10 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2368.00
400 mm RM 2717.00
450 mm RM 3136.00
500 mm RM 3501.00
600 mm RM 4644.00
700 mm RM 5482.00
800 mm RM 6234.00
900 mm RM 7862.00
1000 mm RM 9096.00
1100 mm RM 13258.00
1200 mm RM 14717.00
1300 mm RM 16087.00
1400 mm RM 17911.00
1500 mm RM 20742.00
1600 mm RM 22083.00

150
Sr.No. Item Unit Rate (In Rs.)
11.8 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
10 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 482.00
400 mm RM 562.00
450 mm RM 642.00
500 mm RM 764.00
600 mm RM 863.00
700 mm RM 1012.00
800 mm RM 1158.00
900 mm RM 1453.00
1000 mm RM 1471.00
1100 mm RM 2087.00
1200 mm RM 2324.00
1300 mm RM 2467.00
1400 mm RM 2156.00
1500 mm RM 2325.00
1600 mm RM 2659.00
11.9 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 12 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2371.00
400 mm RM 2723.00
450 mm RM 3141.00
500 mm RM 3513.00
600 mm RM 4656.00
700 mm RM 5505.00
800 mm RM 6522.00
900 mm RM 7869.00
1000 mm RM 9476.00
1100 mm RM 13278.00
1200 mm RM 14738.00
1300 mm RM 16103.00
1400 mm RM 17936.00
1500 mm RM 20976.00
1600 mm RM 22094.00

151
Sr.No. Item Unit Rate (In Rs.)
11.10 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
12 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 482.00
400 mm RM 568.00
450 mm RM 647.00
500 mm RM 769.00
600 mm RM 868.00
700 mm RM 1017.00
800 mm RM 1218.00
900 mm RM 1455.00
1000 mm RM 1542.00
1100 mm RM 2091.00
1200 mm RM 2328.00
1300 mm RM 2471.00
1400 mm RM 2160.00
1500 mm RM 2509.00
1600 mm RM 2783.00
11.11 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 14 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2373.00
400 mm RM 2733.00
450 mm RM 3151.00
500 mm RM 3576.00
600 mm RM 4744.00
700 mm RM 5909.00
800 mm RM 7136.00
900 mm RM 8632.00
1000 mm RM 10876.00
1100 mm RM 13327.00
1200 mm RM 14903.00
1300 mm RM 16890.00
1400 mm RM 19383.00
1500 mm RM 24192.00
1600 mm RM 25464.00

152
Sr.No. Item Unit Rate (In Rs.)
11.12 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
14 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 483.00
400 mm RM 572.00
450 mm RM 663.00
500 mm RM 778.00
600 mm RM 877.00
700 mm RM 1109.00
800 mm RM 1421.00
900 mm RM 1586.00
1000 mm RM 1723.00
1100 mm RM 2100.00
1200 mm RM 2361.00
1300 mm RM 2615.00
1400 mm RM 2376.00
1500 mm RM 2671.00
1600 mm RM 3321.00
11.13 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 16 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2377.00
400 mm RM 2745.00
450 mm RM 3173.00
500 mm RM 3770.00
600 mm RM 5004.00
700 mm RM 6269.00
800 mm RM 7123.00
900 mm RM 9211.00
1000 mm RM 11136.00
1100 mm RM 13762.00
1200 mm RM 15897.00
1300 mm RM 18186.00
1400 mm RM 20849.00
1500 mm RM 24808.00
1600 mm RM 27276.00

153
Sr.No. Item Unit Rate (In Rs.)
11.14 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
16 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 484.00
400 mm RM 577.00
450 mm RM 688.00
500 mm RM 844.00
600 mm RM 955.00
700 mm RM 1217.00
800 mm RM 1492.00
900 mm RM 1714.00
1000 mm RM 1742.00
1100 mm RM 2246.00
1200 mm RM 2626.00
1300 mm RM 2855.00
1400 mm RM 2653.00
1500 mm RM 2996.00
1600 mm RM 3405.00
11.15 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 18 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2381.00
400 mm RM 2753.00
450 mm RM 3326.00
500 mm RM 3959.00
600 mm RM 5282.00
700 mm RM 6631.00
800 mm RM 7596.00
900 mm RM 9789.00
1000 mm RM 11941.00
1100 mm RM 14615.00
1200 mm RM 16933.00
1300 mm RM 19346.00
1400 mm RM 22401.00
1500 mm RM 26495.00
1600 mm RM 29600.00

154
Sr.No. Item Unit Rate (In Rs.)
11.16 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
18 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 485.00
400 mm RM 584.00
450 mm RM 702.00
500 mm RM 874.00
600 mm RM 998.00
700 mm RM 1271.00
800 mm RM 1608.00
900 mm RM 1799.00
1000 mm RM 1841.00
1100 mm RM 2354.00
1200 mm RM 2759.00
1300 mm RM 3070.00
1400 mm RM 2808.00
1500 mm RM 3146.00
1600 mm RM 3709.00
11.17 Providing Bar Wrapped Steel Cylinder
Pipes test Presure 20 Kg/Sqcm including
testing, inspection, trasportaion at site,
transit insurance, loading unloading &
stacking etc. complete.
350 mm RM 2462.00
400 mm RM 2912.00
450 mm RM 3520.00
500 mm RM 4222.00
600 mm RM 5630.00
700 mm RM 7114.00
800 mm RM 8892.00
900 mm RM 10625.00
1000 mm RM 13222.00
1100 mm RM 15835.00
1200 mm RM 18370.00
1300 mm RM 21049.00
1400 mm RM 24614.00
1500 mm RM 29589.00
1600 mm RM 32698.00

155
Sr.No. Item Unit Rate (In Rs.)
11.18 Labour only for laying & jointing Bar
Wrapped Steel Cylinder Pipes test Presure
20 Kg/Sqcm including testing & cost of
jointing material as per relevant IS
specification.
350 mm RM 490.00
400 mm RM 595.00
450 mm RM 734.00
500 mm RM 940.00
600 mm RM 1075.00
700 mm RM 1378.00
800 mm RM 1737.00
900 mm RM 1978.00
1000 mm RM 2018.00
1100 mm RM 2593.00
1200 mm RM 3031.00
1300 mm RM 3381.00
1400 mm RM 3053.00
1500 mm RM 3436.00
1600 mm RM 3981.00

156
CHAPTER –XII

STONE WARE PIPES FOR SEWERS

157
CHAPTER XII
STONE WARE PIPES FOR SEWERS
(Pipes conforming to IS: 651-1992)

Notes :
1.1 The salt Glazed stoneware pipe shall be confirming to IS-651 : 1992.
1.2 The laying to S.W. pipes shall be done as per IS - 4127 : 1983
1.3 The bedding of the S.W. pipes shall be as per the specification given in the
CPHEEO mannual of sewerage & sewage treatment, payment for which
shall be made as per chapter XII allied civil works.
1.4 The testing of the sewer line& refilling sahll be done as per CPHEEO
manual on sewerage and sewage management.
1.5 In order to avoid damage to the pipes and especially to the spigot end, pipes
shall not be dragged along concrete and similar pavements with hard
surfaces.
1.6 The pipes and fittings shall be inspected for defects and be rung with a light
hammer preferable while suspended to detect cracks.
1.7 All lumps, blisters and excess coating materials shall be removed gently
from the socket and spigot of each pipe. The out side of the spigot and the
inside of the socket shall be wiped clean and dry before the pipe is laid.
1.8 In shallow trenches, manual handing is enough but in deep trenches, they
shall be lowered in to the trench by mean of ropes. Under no
circumstances the pipe shall be dropped or dumped into the trench.

1.9 Every precaution shall be taken to prevent foreign material from entering
the pipe when it is being placed in the line.

1.10 The pipe between two manholes shall be laid truly in a straight line without
vertical and horizontal undulations. The pipe shall be laid true to line and
grade as specified in the relevant specifications.

2 Laying:

2.1 while unloading, pipes shall not be thrown from the truck on hard ground.

3. Trenches:
The width of trench at and below the top of sewer should be the minimum
necessary for its proper installation with the due consideration to its bedding. It
should be as per clause 7.1.1 page 126 of construction of sewers as per
CPHEEO manual on sewerage and sewage treatment (second edition).
3.1 Unloading of pipes on timber skids without a steadying rope and thus allowing
the pipes to bump hard against one another should not be allowed.

158
3.2 Where the sewer has to be laid in a soft under ground strata or in a reclaimed
land, the trench shall be excavated deeper than what is ordinary required. The
trench bottom shall be stabilised by the addition of coarse gravel or rock, in
case of very bed soil the trench bottom shall be filled in with cement concrete.
For class of bedding details clause 6.5.3.1 page 116 of CPHEEO manual on
sewerage and sewage treatment should be followed.

3.3 In order to avoid damage to the pipes and especially to the spigot end, pipes
should not be dragged along concrete and similar pavements with hard surfaces.

3.4 The pipe and fittings shall be inspected for defects and be rung with a light
hammer preferably while suspended, to detect cracks.

3.6 All lumps, blisters and excess coating materials shall be removed gently from
the socket and spigot end of each pipe and the outside of the spigot and the
inside of the socket shall be wiped clean an dry before the pipe is laid.

3.7 In shallow trenches manual handling is enough but in deep trenches, they
should be lowered into the trench by means of ropes. Under no circumstances
shall not the pipes be dropped or dumped into the trench.

3.8 Every precaution shall be taken to prevent foreign materials from entering the
pipe when it is being placed in the line.

3.9 The pipes between two main holes shall be laid truely in a straight line without
vertical and horizontal undulations. The pipes shall be laid true to line and
grade as specified.

3.10 Sight rails provided at all changes of direction or gradient sand at distances of
about 15 meters along straight lengths, with centre line marked each horizontal
rail, which is fixed at true level, shall be used for laying all inverts.

3.11 Normally the socket ends should face the up stream. When the line runs up hill
the socket ends should face the upgrade.

3.12 The stone ware pipes shall be laid with sockets facing up the gradient, on
desired, special bedding. Hunching or encasing may be provided where
conditions so demand as discussed in clause 6.5 of CPHEEO manual on
sewerage and sewage treatment.

3.14 Where pipes are not bedded on concrete, the trench floor shall be left slightly
high and carefully buttoned up as pipe laying proceeds, so that the pipes
barrels rest on firm and undisturbed ground. If the excavation has been carried
too low the desired levels shall be made up with concrete 1:5:10 (1cement: 5
fine cement: 10 graded stone aggregate 40 mm nominal size) for which no
extra payment shall be made. The pipe shall be secured in place with approved
back fill material or concrete tamped under it except at the socket.

159
3.15 Pipe and fittings, which do not allow a sufficient and uniform space for
joints, shall be removed and replaced with pipe and fittings of proper
dimensions to ensure such uniform space.

3.16 At times when pipe laying is not in progress, the open ends of pipe shall be
closed by a water light plug or canvas or other means approved by the
Engineer in charge.

3.17 Trenches shall be kept free from water until the material in the joints has
hardens.

3.18 When the pipe is closed and the trench to be flooded by rain; care shall be
taken to prevent the pipe from floating.

3.19 The cutting of pipe for inserting, fittings or closure pieces shall be done in a
neat and work manlike manner without damage to the pipe or inside coating
so as to leave a smooth surface and at right angle to the axis of the pipe.

3.20 The Engineer In-charge should consult the appropriate authorities before
preparing plans and specifications for pipeline crossing Railway lines,
Irrigation channels or similar works.

3.21 The connection to an existing sewer shall be done through manholes.

3.22 Before connecting a pipe to a manhole, a relieving arch or any other similar
protection device should be made in the manhole for the safety of the pipe.

3.23 The pipes when laid, should not be subjected to superimposed load beyond
their safe crushing strength.

4. Jointing:

4.1 The stoneware pipes shall be cement jointed.

4.2 The materials shall consist of the following.

(a) Spun yarn or tarred gaskets.

(b) Cement.

(c) Sand

4.3. In each joint, spun yarn soaked in neat cement slurry or tarred gasket shall
be passed round the joint and inserted in it by means of a caulking tool.

160
More yarn or gasket shall be added if necessary and shall be well caulked.
Yarn or gasket so rammed shall not occupy more then one fourth of the
depth of socket.

4.4 Cement mortar (1:1) (one part of cement to one part of sand) shall be
slightly moistened and carefully inserted by hand into the remaining space of
the joint after caulking of yarn or gasket. The mortar shall than be caulked
into the joint with a caulking tool. More cement mortar shall be added until
the joint space has been completely filled with tightly caulked mortar. The
joint shall then be finished off neatly outside the socket at an angle of 45
degrees (IS 4127-1983)

4.5 The cement mortar joints shall be cured at least for seven days before
testing.

4.6 The joint with cast iron or concrete pipes shall be made with cement joints.

5. Testing:

5.1 Each section of sewer shall be tested for water tightness preferably between
manholes.

5.2 Before commencing the hydraulic test the pipelines shall be filled with water
for about a week before commencing the application of pressure to allow for
the absorption by pipe wall.
.
5.3 The sewers are tested by plugging the upper end with a provision for an air
out let pipe with stopcock. The water is filled through a funnel connected at
the lower end provided with a plug. After the air has expelled through the air
out let, the stop cock is closed and water level in the funnel is noted after 30
minutes and gravity of water required to restore the original water level is
determined. The pipe line under pressure is then inspected while the funnel
is still in position. There shall be no any leaks in the pipe or joints (small
sweating on the pipe surface is permitted).

5.4 Any sewer or part there of that does not meet the test shall be emptied and
repaired or re-laid as required and tested again..

5.5 The leakage of quantity of water to be supplied to maintain the test pressure
during the period of 10 minutes shall not exceed 0.2 litres/mm dia. of pipe
per kilometre length per day.

5.6 It should be done as per clause 7.1.5 page 131 of CPHEEO manual on
sewerage and sewage treatment.

161
6. Refilling :

No trench shall be filled in unless the sewer stretches have been tested and
approved for water tightness of joints. However partial filling may be done
keeping the joints open to avoid disturbance. Soft material screened free
from stones or hard substances shall first be used and hand pressured under
and around the pipes to half their height. Similarly soft material shall be put
up to a height of 30cm above top of pipe and then this will be moistened
with water and well rammed. The reminder of the trench can be filled with
hard material, in stages, each not exceeding 60 cm. At each stage the filling
shall be well rammed, consolidated and completely saturated with water and
then only further filling shall be continued. It should be done as per
procedure given in clause 7.1.9 page 133 of CPHEEO manual on sewerage
and sewage treatment.

7. Measurements:

The lengths of pipe shall be measured in the running meters nearest to a cm


as laid or fixed, from inside of one manhole to the inside of the other
manhole the length shall be taken. Along the centre line of the pipes overall
fittings. Such as bends, junction, etc., which shall not be measured
separately. Excavation refilling shoring and timbering in trenches and
cement concreting where ever required shall be measured separately under
relevant item of work.

8. Rate :

The rate shall include the cost of material and labour involved in all the
operation described above including the cost of concrete which shall be paid
separately.

9. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at
the gross amount.

162
STONE WARE PIPES FOR SEWERS
(Pipes conforming to IS: 651-1992)

S. No. Items Unit Rates in Rs.


12.1 Providing and Laying and Jointing salt
glazed stone ware (S.W.) pipes socket and
spigot with stiff cement mortar 1:1
including testing of joints complete
100mm R. Meter 252.00
150 mm R. Meter 364.00
200 mm R. Meter 588.00
250 mm R. Meter 942.00
300 mm R. Meter 1250.00
12.2 Labour only for Laying and Jointing salt
glazed stone ware (S.W.) pipes s&s
(socket and spigot) with stiff cement
mortar 1:1 including testing of joints
complete.
100mm R. Meter 81.00
150 mm R. Meter 117.00
200 mm R. Meter 139.00
250 mm R. Meter 182.00
300 mm R. Meter 207.00
12.3 Providing and laying cement concrete
1:5:10 (1 cement:5 fine send: 10 graded
stone aggregate 40 mm nominal size)
around S.W. pipe including bed concrete
15 cm thick i/c curing, testing etc.
complete for 100 mm dia. to 300 mm dia
pipe.(For type" Concrete Alround" )
100mm dia SW pipe R. Meter 514.00
150mm dia R. Meter 628.00
200mm dia R. Meter 733.00
250mm dia R. Meter 802.00
300mm dia R. Meter 972.00
12.4 Providing and laying cement concrete
1:5:10 (1 cement:5 fine send: 10 graded
stone aggregate 40 mm nominal size) up
to haunches of SW – pipes including bed
concrete i/c curing, testing etc complete
for 100mm to 300mm dia SW pipe For
Type "Concrete up to Haunches ")

163
S. No. Items Unit Rates in Rs.
100mm dia pipe R. Meter 244.00
150mm dia R. Meter 394.00
200mm dia R. Meter 465.00
250mm dia R. Meter 542.00
300mm dia R. Meter 625.00
12.5 Dismantling of old S.W. pipes including
breaking of joints and bed concrete
stacking of useful materials near the site
within 50 m lead and disposal of
unserviceable materials in to municipal
dumps :
100mm dia pipe R. Meter 27.00
150mm dia R. Meter 30.00
200mm dia R. Meter 32.00
250mm dia R. Meter 34.00
300mm dia R. Meter 36.00

164
CHAPTER- XIII

REINFORCED CEMENT CONCRETE PIPES

165
CHAPTER- XIII
REINFORCED CEMENT CONCRETE PIPES
(PIPES CONFORMING TO IS : 458-1988)
NOTES :
All the pipes, specials, joints to be used in the work shall conform to
relevant Indian Standards duly inspected and tested and having B.I.S.
certification mark.

1. Laying:

1.1 Reasonable care shall be exercised in loading, transporting and unloading


concrete pipes. Handling shall be such as to avoid impact. Gradual
unloading by inclined plane or by chain block is recommended.

1.2 Pipes shall be lowered in to the trench carefully by mechanical appliances.


Under no circumstances shall the pipes be dropped or dumped in to the
trench.

1.3 All pipe sections and connections shall be inspected carefully before being
laid. Broken or defective pipes or connections shall not be used.

1.4 All lumps, blisters and excess coating materials shall be removed gently
from the ends of each pipe and they should be wiped clean and dry before
the pipe is laid.

1.5 In the case of pipes with joints to be made with loose collars, the collars
shall be slipped on before the next pipe is laid.

1.6 Every precaution shall be taken to prevent foreign materials from entering
the pipe when it is being placed in the line

1.7 Pipes shall be laid in true line and grade, as specified.

1.8 Sight rails provided at all change of directions or gradients and at distances
of about 15 metered along. Straight lengths with centre line marked on each
horizontal rail which is fixed at true level, shall be used for laying all inverts
with the help of proper boning rods.

1.9 Laying of pipes shall always proceed upgrade of a slope. If the pipes have
spigot and socket joints, the socket ends shall face upstream. In the cases of
pipes with joints to be made with loose collars, the collars shall be slipped
one before the next pipe is laid.

1.10 The pipe shall be secured in place with approved back fill material or
concrete tamped under it except at the joint portion.

166
1.11 Precautions shall be taken to prevent dirt from entering the joint space.

1.12 When pipe laying is not in progress, the open ends of pipe shall be closed by
a water tight plug or canvas or other means approved by the Engineer in
charge.

1.13 Trench shall be kept free from water until the material in the joints has
hardened.

1.14 When the pipe is closed and the trench liable to be flooded by rain, care shall
be taken to prevent the pipe from floating.

1.15 Walking or working on the completed pipe shall not be permitted until the
trench has been back filled to a height of at least 30 CM over the pipe,
except as may be necessary in tamping or back filling.

1.16 The cutting of pipe for inserting, fittings or closure pieces shall be done in a
neat and workmanlike manner without danger to the pipe so as to leave a
smooth surface and at right angles to the axis of the pipe.

1.17 The Engineer-in-Charge should consult the appropriate authorities before


preparing plans and specifications for pipe line crossing railway lines,
Irrigation, channels or similar other works and services.

1.18 The connection to an existing sewer shall be done through manholes.

1.19 Before connecting a pipe to a manhole, a relieving arch or any other similar
protection device should be made in the manhole for the safety of the pipe.

1.20 The pipe when laid should not be subjected to super imposed load beyond
what the pipe can safety take up.

2. Pipe Bedding:

2.1 In case where the foundation conditions are unsafe such as in the proximity
of trees or poles, under existing or proposed tracks, under manholes etc; the
pipe shall be encased, in low strength concrete bedding or compacted sand
or gravel.

2.2 The following class of pipe beddings are recommended as per CPHEEO
manual. The class of bedding depends upon the site condition and loading.

Class A bedding It may either concrete cradle or concrete arch


depend upon the design.
Class B bedding- It is having a shaped bottom or compacted
granular bedding with a carefully compacted
back fill.

167
Class C bedding- It is ordinary bedding having a compacted
granular bedding with a lightly compacted back
fill.

2.3 The pipe bedding materials must remain firm and not permit displacement of
pipes. Where rock or other unyielding foundation material is encountered,
bedding shall be according to one of the classes A, B or C but with the
following additional requirements.
Class A bedding-The hard unyielding material should be excavated down to
the bottom of the concrete cradle.
Class B or C bedding- The hard unyielding material should be excavated
below the bottom of the pipe and pipe bell to depth of at least 15cm.
The width of trench should be at least 1.25 times the outside dia of pipe and
it should be refilled with granular material.

2.4 When the pipe is laid in a trench in rock, hard clay, shale or other hard
material, the space below the pipe shall be excavated and replaced with an
equalising bed of concrete, sand or compacted earth. In no place the pipe
shall be laid directly on such hard material.

2.5 The bedding shall be as per details given in chapter VI 'Structural design of
buried sewer' given in CPHEEO manual on sewerage and sewage treatment
(1993 second edition).

3. Jointing:

(a) The socket and spigot pipes are laid and jointed with rubber gasket.

(b) In case of collar jointed pipe, the jointing shall be done with hemp yarn
soaked in cement slurry tamped with just sufficient quantity of water to have
a consistency of semi dry condition, well packed and thoroughly rammed
with caulking tools and then filled with cement mortar 1:2. The joint shall be
finished off with a fillet slopping at 45 degrees to the surface of the pipe.
The finished joint shall be protected and cured for at least 24 hours. For
jointing, procedure shall be followed as per I.S. 783 – 1985.

4. Testing:
4.1 Each section of sewer shall be tested for water tightness preferably between
manholes.
4.2 In case of cement mortar joints, the sewer line shall be tested three days after
the cement mortar joints have been made.
4.3 The pipe line shall be filled with water for about a week before commencing
the application of pressure to allow for the absorption by pipe wall.
4.4 The pipe line shall be tested by plugging the upper end with a provision for
an air outlet pipe with stop cock. The water shall be filled through a funnel
connected at the lower end provided with a plug. After expelling the air

168
through the air outlet, the stop cock shall be closed and water level in the
funnel shall be raised to 2.5 m above the invet at the upper end. Water level
in the funnel is noted after 30 minutes and the quantity of water required to
restore the original water level in the funnel is determined. The pipe line
under pressure is then inspected while funnel is still in position. There shall
not be any leaks in the pipe or joints (small sweating on the pipe surface is
permitted).
4.5 Any sewer or part thereof that doesn’t meet the test shall be emptied and
repaired or re-laid as required and tested again.
4.6 The leakage or quantity or water to be supplied to maintain the test pressure
during the period of 10 minutes should not exceed 0.2 liters/mm diameter of
pie per Km. length per day.
4.7 For non pressure pipes the leakage should be observed for a period of 24
hours .
4.8 Ex filtration test for detection of leakage shall be carried out at a time when
the ground water table is low.
4.9 Air testing shall be done particularly in large diameter pipes when the
required quantity of water is not available for testing subjected to the
provisions made in the agreement. It is done as per procedure given in
CPHEEO manual ( 1993 second edition).

5. Back filling of trenches:

The method of backfilling to be used shall vary with the width of trench, the
character of material excavated, the method of excavation and degree of
compaction required.
(1) In open country, it shall be sufficient to mound the trench and after natural
settlement return to regrade the areas.
(2) In developed streets, it shall be compacted to minimize the load.
(3) Soft material screened free from stones or hard substances shall first be used
and hand pressed under and around the pipes to half the height. Similar soft
material shall then be put up to a height of 30 cm. above the top of pipe and
this will be moistened with water and well rammed. The remaining trench
can be filled with hard material, in layers each not exceeding 60 cm. At
each stage the filling shall be well rammed, consolidated and completely
saturated with water and then only further filling shall be continued.

6. This USOR contains the rates of all the items without GST. GST shall
be paid separately as per prevailing government norms as claimed by
the contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at
the gross amount.

169
CHAPTER XIII
REINFORCED CEMENT CONCRETE PIPES
(PIPES CONFORMING TO IS : 458-1988)

Sr.No. Item Unit Rate (In Rs.)


13.1 Providing and Laying non-pressure (NP2)
RCC socket & spigot pipes with rubber
gasket joint including testing of joints.
100 mm Dia Per Meter 418.00
150 mm Dia Per Meter 436.00
200 mm Dia Per Meter 508.00
250 mm Dia Per Meter 617.00
300 mm Dia Per Meter 843.00
350 mm Dia Per Meter 965.00
400 mm Dia Per Meter 1127.00
450 mm Dia Per Meter 1361.00
500 mm Dia Per Meter 1481.00
600 mm Dia Per Meter 1868.00
700 mm Dia Per Meter 2449.00
800 mm Dia Per Meter 3201.00
900 mm Dia Per Meter 3750.00
1000 mm Dia Per Meter 4341.00
1100 mm Dia Per Meter 5211.00
1200 mm Dia Per Meter 6494.00
1600 mm Dia Per Meter 10420.00
13.2 Labour only for Laying and Jointing non-
pressure (NP2) RCC socket & spigot pipes
with rubber gasket joint including testing of
joints.
100 mm Dia Per Meter 76.00
150 mm Dia Per Meter 120.00
200 mm Dia Per Meter 139.00
250 mm Dia Per Meter 180.00
300 mm Dia Per Meter 223.00
350 mm Dia Per Meter 226.00
400 mm Dia Per Meter 258.00
450 mm Dia Per Meter 296.00
500 mm Dia Per Meter 329.00
600 mm Dia Per Meter 399.00
700 mm Dia Per Meter 447.00
800 mm Dia Per Meter 534.00
900 mm Dia Per Meter 642.00
1000 mm Dia Per Meter 703.00
1100 mm Dia Per Meter 775.00
1200 mm Dia Per Meter 890.00
1600 mm Dia Per Meter 1285.00
13.3 Providing and Laying non-pressure (NP3)
RCC socket & spigot pipes with rubber
gasket joint including testing of joints.

170
Sr.No. Item Unit Rate (In Rs.)
150 mm Dia Per Meter 568.00
250 mm Dia Per Meter 888.00
300 mm Dia Per Meter 1109.00
350 mm Dia Per Meter 1502.00
400 mm Dia Per Meter 1927.00
450 mm Dia Per Meter 2129.00
500 mm Dia Per Meter 2411.00
600 mm Dia Per Meter 2901.00
700 mm Dia Per Meter 3831.00
800 mm Dia Per Meter 4849.00
900 mm Dia Per Meter 5752.00
1000 mm Dia Per Meter 6564.00
1100 mm Dia Per Meter 7497.00
1200 mm Dia Per Meter 8243.00
1400 mm Dia Per Meter 10320.00
1600 mm Dia Per Meter 12168.00
1800 mm Dia Per Meter 15568.00
13.4 Labour only for laying and Jointing non-pressure
(NP3) RCC socket & spigot pipes with rubber
gasket joint including testing of joints.
150 mm Dia Per Meter 120.00
250 mm Dia Per Meter 165.00
300 mm Dia Per Meter 229.00
350 mm Dia Per Meter 355.00
400 mm Dia Per Meter 389.00
450 mm Dia Per Meter 444.00
500 mm Dia Per Meter 477.00
600 mm Dia Per Meter 591.00
700 mm Dia Per Meter 653.00
800 mm Dia Per Meter 797.00
900 mm Dia Per Meter 985.00
1000 mm Dia Per Meter 1097.00
1100 mm Dia Per Meter 1140.00
1200 mm Dia Per Meter 1233.00
1400 mm Dia Per Meter 1599.00
1600 mm Dia Per Meter 1899.00
1800 mm Dia Per Meter 2228.00
13.5 Providing and Laying non-pressure (NP4)
RCC socket & spigot pipes with rubber
gasket joint including testing of joints.
250 mm Dia Per Meter 992.00
300 mm Dia Per Meter 1410.00
350 mm Dia Per Meter 1980.00
400 mm Dia Per Meter 2301.00
450 mm Dia Per Meter 2762.00
500 mm Dia Per Meter 3124.00
600 mm Dia Per Meter 3626.00
700 mm Dia Per Meter 4465.00
800 mm Dia Per Meter 5656.00
171
Sr.No. Item Unit Rate (In Rs.)
900 mm Dia Per Meter 6622.00
1000 mm Dia Per Meter 7500.00
1100 mm Dia Per Meter 8245.00
1200 mm Dia Per Meter 9168.00
1400 mm Dia Per Meter 11734.00
1600 mm Dia Per Meter 14203.00
1800 mm Dia Per Meter 18233.00
13.6 Labour only for laying and jointing non-
pressure (NP4) RCC socket & spigot pipes
with rubber gasket joint including testing of
joints.
250 mm Dia Per Meter 191.00
300 mm Dia Per Meter 249.00
350 mm Dia Per Meter 362.00
400 mm Dia Per Meter 409.00
450 mm Dia Per Meter 451.00
500 mm Dia Per Meter 498.00
600 mm Dia Per Meter 598.00
700 mm Dia Per Meter 674.00
800 mm Dia Per Meter 825.00
900 mm Dia Per Meter 1006.00
1000 mm Dia Per Meter 1121.00
1100 mm Dia Per Meter 1169.00
1200 mm Dia Per Meter 1316.00
1400 mm Dia Per Meter 1686.00
1600 mm Dia Per Meter 1899.00
1800 mm Dia Per Meter 2228.00
13.7 Providing, Laying & jointing non-pressure
(NP2) RCC pipes with collars jointed with
stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints.
150 mm Dia Per Meter 269.00
200 mm Dia Per Meter 392.00
250 mm Dia Per Meter 418.00
300 mm Dia Per Meter 492.00
350 mm Dia Per Meter 611.00
400 mm Dia Per Meter 709.00
450 mm Dia Per Meter 849.00
500 mm Dia Per Meter 879.00
600 mm Dia Per Meter 974.00
700 mm Dia Per Meter 1534.00
800 mm Dia Per Meter 2041.00
900 mm Dia Per Meter 2629.00
1000 mm Dia Per Meter 3179.00
1100 mm Dia Per Meter 3671.00
1200 mm Dia Per Meter 4473.00
13.8 Labour only for laying & jointing non-
pressure (NP2) RCC pipes with collars jointed
172
Sr.No. Item Unit Rate (In Rs.)
with stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints.
150 mm Dia Per Meter 65.00
200 mm Dia Per Meter 86.00
250 mm Dia Per Meter 108.00
300 mm Dia Per Meter 115.00
350 mm Dia Per Meter 128.00
400 mm Dia Per Meter 134.00
450 mm Dia Per Meter 147.00
500 mm Dia Per Meter 156.00
600 mm Dia Per Meter 186.00
700 mm Dia Per Meter 205.00
800 mm Dia Per Meter 220.00
900 mm Dia Per Meter 277.00
1000 mm Dia Per Meter 351.00
1100 mm Dia Per Meter 425.00
1200 mm Dia Per Meter 523.00
13.9 Providing, Laying & jointing non-pressure
(NP3) RCC pipes with collars jointed with
stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints
150 mm Dia Per Meter 344.00
200 mm Dia Per Meter 510.00
250 mm Dia Per Meter 564.00
300 mm Dia Per Meter 656.00
350 mm Dia Per Meter 982.00
400 mm Dia Per Meter 1376.00
450 mm Dia Per Meter 1474.00
500 mm Dia Per Meter 1651.00
600 mm Dia Per Meter 1915.00
700 mm Dia Per Meter 2975.00
800 mm Dia Per Meter 3140.00
900 mm Dia Per Meter 3673.00
1000 mm Dia Per Meter 4411.00
1100 mm Dia Per Meter 5228.00
1200 mm Dia Per Meter 5527.00
13.10 Labour only for laying & jointing non-
pressure (NP3) RCC pipes with collars jointed
with stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints.
150 mm Dia Per Meter 68.00
200 mm Dia Per Meter 90.00
250 mm Dia Per Meter 112.00
300 mm Dia Per Meter 120.00
350 mm Dia Per Meter 134.00
400 mm Dia Per Meter 139.00
173
Sr.No. Item Unit Rate (In Rs.)
450 mm Dia Per Meter 153.00
500 mm Dia Per Meter 162.00
600 mm Dia Per Meter 193.00
700 mm Dia Per Meter 213.00
800 mm Dia Per Meter 229.00
900 mm Dia Per Meter 288.00
1000 mm Dia Per Meter 364.00
1100 mm Dia Per Meter 442.00
1200 mm Dia Per Meter 544.00
13.11 Providing, Laying & jointing non-pressure
(NP4) RCC pipes with collars jointed with
stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints
150 mm Dia Per Meter 371.00
200 mm Dia Per Meter 520.00
250 mm Dia Per Meter 606.00
300 mm Dia Per Meter 832.00
350 mm Dia Per Meter 1359.00
400 mm Dia Per Meter 1440.00
450 mm Dia Per Meter 1546.00
500 mm Dia Per Meter 1774.00
600 mm Dia Per Meter 2042.00
700 mm Dia Per Meter 3156.00
800 mm Dia Per Meter 3307.00
900 mm Dia Per Meter 3888.00
1000 mm Dia Per Meter 4685.00
1100 mm Dia Per Meter 5301.00
1200 mm Dia Per Meter 5738.00
13.12 Labour only for Laying & jointing non-
pressure (NP4) RCC pipes with collars jointed
with stiff mixture of cement mortar in the
proportion 1:2 ( 1 cement : 2 sand ) including
testing of joints.
150 mm Dia Per Meter 71.00
200 mm Dia Per Meter 94.00
250 mm Dia Per Meter 117.00
300 mm Dia Per Meter 125.00
350 mm Dia Per Meter 139.00
400 mm Dia Per Meter 145.00
450 mm Dia Per Meter 159.00
500 mm Dia Per Meter 168.00
600 mm Dia Per Meter 200.00
700 mm Dia Per Meter 221.00
800 mm Dia Per Meter 238.00
900 mm Dia Per Meter 298.00
1000 mm Dia Per Meter 377.00
1100 mm Dia Per Meter 459.00
1200 mm Dia Per Meter 566.00
174
CHAPTER- XIV

DOUBLE WALL CORRUGATED (DWC) PIPES

175
CHAPTER- XIV
DOUBLE WALL CORRUGATED (DWC) PIPES

1. Dimensions of Pipes : (i) Mean outside diameter :- The mean outside diameter,
outside diameter at any point and tolerances shall be as give in the table 1 of IS
15328 and shall be measured according to the method in IS:12235 (part-1). (ii)
Wall thickness :- The nominal wall thickness, e, shall be in accordance with
table 2 of IS 15328. Tolerances in outside diameters shall be those given in IS
4985.

2. Marking :- The colour of marking shall be different from the basic colour of
the pipe. It shall be as under. (i) Identification of the source of manufacture. (ii)
Outside diameter, (iii) Stiffness class, and (iv) Batch or lot number

3. Joints : Elastomeric Sealing rings :- Elastomeric sealing rings shall be free from
substances (for example, plasticizers) that can have a detrimental effect on the
polyvinyl chloride of the pipe or fittings used in conjunction with the pipes.

4. Laying of pipes includes all precautions to guard against possible damage to


the existing structure/pipes lines, cables etc., taking precautions to prevent dirt
from entering the pipe ends, lowering and laying pipes and specials in the
trenches with specials arrangement such as cranes, tripods with chain pulley
block, use of slings of canvas etc. to fit the ends of pipes and fittings/ specials to
lift and lower the same. Inspection of pipes and fittings for defects by striking
with a light hammer while suspended. Laying of pipes perfectly true in
alignment and to gradient etc.

5. Minimum Cover
5.1 A minimum cover of 0.9 m should be ensured when normal truck traffic is
expected and 1.8m should be ensured when heavy truck traffic is expected.
5.2 Bedding and backfill material must be free from boulders, sharp stones, flints
etc.
5.3 Bedding should be prepared by laying on soft soil duly compacting and
watering so that thickness of bedding is 100 mm to 150 mm. Please refer
Drawing No. 3
6. Providing and supply of DWC HDPE pipes class SN8 for non pressure
underground sewerage drainage application as per EN: 13476-3 is also given in
the given chapter. Pipes and fittings shall be as per relevant BIS/ISO
specifications. Material should be used after obtaining third party quality
assurance certificate
7. Measurement
All measurement should be of the finished work only. The net length of pipes as
laid or fixed shall be measured in running meters correct to 10mm. The portion
of the pipe inside the joints shall not be included in the length of pipe work.

176
Excavation, refilling, masonry and concrete work wherever required shall be
measured and paid for separately under relevant items of work.

8. Rates
The rate shall include the cost of material and labour involved in all the
operation described above excluding the cost of concrete which shall be paid
separately.

9. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

DOUBLE WALL CORRUGATED (DWC) PIPES

S.No. Items Unit Rate in Rs.


14.1 Providing of DWC/ PE (Earlier RM
HDPE) Pipes of renowned
manufacturer duly tested and
inspected i/c transportation
charges, transit insurance,
loading/ unloading and stacking at
site/ store etc, complete.
Internal Dia/Outer dia
14.1.1 100 mm/ 120 mm RM 147
14.1.2 135 mm/ 160 mm RM 220
14.1.3 150 mm/ 180 mm RM 260
14.1.4 170 mm/ 200 mm RM 314
14.1.5 200 mm/ 238 mm RM 431
14.1.6 250 mm/ 290 mm RM 671
14.1.7 300 mm/ 345 mm RM 895
14.1.8 400 mm/ 480 mm RM 1619
14.1.9 500 mm/ 580 mm RM 2360
14.1.10 600 mm/ 715 mm RM 4069
14.1.11 800 mm/ 955 mm RM 6747
14.1.12 1000 mm/ 1200 mm RM 10989
14.2 Laying and jointing of DWC /PE
(HDPE) Pipes of renowned
manufacturer duly tested, and
inspected i/c transportation
charges, transit insurance, loading/
unloading and stacking at site/
store etc, complete.
Internal Dia/Outer dia
14.2.1 100 mm/ 120 mm RM 24.00
177
S.No. Items Unit Rate in Rs.
14.2.2 135 mm/ 160 mm RM 26.00
14.2.3 150 mm/ 180 mm RM 37.00
14.2.4 170 mm/ 200 mm RM 37.00
14.2.5 200 mm/ 238 mm RM 37.00
14.2.6 250 mm/ 290 mm RM 47.00
14.2.7 300 mm/ 345 mm RM 90.00
14.2.8 400 mm/ 480 mm RM 90.00
14.2.9 500 mm/ 580 mm RM 146.00
14.2.10 600 mm/ 715 mm RM 146.00
14.2.11 800 mm/ 955 mm RM 189.00
14.2.12 1000 mm/ 1200 mm RM 258.00
14.3 Providing fittings for structural
wall polyethylene piping systems (
pipe with online/offline coupler
and elasticmeric sealing ring) with
non-smooth external annular
corrugated and smooth internal
surfaces (double wall) for non –
pressure underground sewerage,
drainage as per IS 16098(PART-
2):2013&EN 13476-3.

Internal dia/Outer dia Coupler Sealing Bend


Rate Ring Rate
Rate
14.3.1 100 mm/ 120 mm RM 47.00 11.00 204.00
14.3.2 135 mm/ 160 mm RM 81.00 20.00 310.00
14.3.3 150 mm/ 180 mm RM 110.00 23.00 370.00
14.3.4 170 mm/ 200 mm RM 167.00 34.00 538.00
14.3.5 200 mm/ 238 mm RM 204.00 59.00 645.00
14.3.6 250 mm/ 290 mm RM 502.00 128.00 1148.00
14.3.7 300 mm/ 345 mm RM 1053.00 280.00 1756.00
14.3.8 400 mm/ 480 mm RM 1670.00 516.00 3340.00
14.3.9 500 mm/ 580 mm RM 2344.00 617.00 4793.00
14.3.10 600 mm/ 715 mm RM 3292.00 1623.00 8013.00
14.3.11 800 mm/ 955 mm RM 7037.00 3967.00 16846.00
14.3.13 1000 mm/ 1200 mm RM 10398.00 5908.00 24480.00

178
CHAPTER- XV

SEWER APPURTENANCES

179
CHAPTER XV
SEWER APPURTENANCES

SEWER APPURTENANCES
Following are the General Sewer Appurtenances-
(I) Manholes
(II) Inverted Siphons
(III) Storm Water Inlets
(IV) Sewer Ventilators
Out of the above, manholes are the most essential items in any sewerage
system.

1 Manholes
1.1 Function

Manholes is the essential ancillary structure in any sewerage system. They shall
be provided for inspection, testing, cleaning, repairing and removal of
obstruction from sewer line.

1.2 Provision: -
Manholes should be built at every change of alignment, gradient or diameter, at
the head of all sewer and branches and at every junction of two or more sewers,
on sewer, which is to be cleaned manually or which cannot be entered for
cleaning or inspection.

1.3 Spacing: -
The Maximum spacing of manholes in the sewer shall be kept as follows: -
Pipe dia (mm) Max. Spacing (mt)
Upto 900 30
900 to 1500 90-150
1500 to 2000 150-200
Above 2000 300

A spacing allowance of 100m per 1m dia of sewer is a general rule in case of


very large sewers.

1.4 Types of manholes:

Following is the general classification of manholes-

1.4.1 Straight-through manholes: -

The simplest type of manhole is that built on a straight run of sewer with no side
junctions. Where there is a change in the size of sewer, the soffit or crown
level of the two sewers should be the same, except where special conditions
require otherwise.

180
1.4.2 Junction Manholes: -

A manhole should be built at every junction of two or more sewers, and the
curved portions of the inverts of tributary sewers should be formed within the
manhole. To achieve this with the best economy of space, the chamber may be
built of a shape other than rectangular. The soffit of the smaller sewer at a
junction should be not lower than that of the larger sewer, in order to avoid the
surcharging of the former when the letter is running full, and the hydraulic
design usually assumes such a condition. The gradient of the smaller sewer may
be increased from the previous manhole sufficiently to reduce the difference of
invert level at the point of junction to a convenient amount.

1.4.3 Side Entrance Manholes: -

In large sewer or where it is difficult to obtain direct vertical access to the sewer
from ground level, owing to existing services, gas, water etc. the access shaft
should be constructed in the nearest convenient position off the line of sewer,
and connected to the manhole chamber by a lateral passage.

In the tunnelled sewer the shaft and the lateral access heading may be used as a
working shaft, the tunnel being broken out from the end of the heading, or
alternatively the shaft and heading may be used as a working shaft, the tunnel
being broken out from the end of the heading, or alternatively the shaft and
heading maybe constructed after the main tunnel is completed, provision having
been made for breaking in from the access heading to build the chamber.

The floor of the side-entrance passage, which should fall at about 1 in 30


towards the sewer, should enter the chamber not lower than the soffit level of
the sewer. In large sewer where the floor of the side entrance passage is above
the soffit either steps or a ladder (which should be protected either by a
removable handrail or by safety chains) should be provided to reach the
benching.

1.4.4 Drop Manholes; -

When a sewer connects with another sewer, where the difference in level
between water lines (peak flow levels) of main line and the invert level of
branch line is more than 600 mm or a drop of more than 600 mm is required to
be given in the same sewer line and it is uneconomical or impractical to arrange
the connection with in 600 mm a drop connection shall be provided for which is
manholes maybe built incorporating a vertical or nearly vertical drop pipe from
the higher sewer to the lower one. This pipes maybe either outside the shaft and
enclosed in concrete or supported on brackets inside the shaft, which should be
suitably enlarged. If the drop pipe is outside the shaft, a continuation of the
sewer should be built through the shaft wall to from a rodding and inspection
eye, which should be provided with a half blank flange. If the drop pipe is
inside the shaft. It should be in cast iron and it would be advantageous to

181
provide adequate means for rodding and water cushion of 150 mm depth should
also be provided. The diameter of the backdrop should be at-least as large as
that of the incoming pipe

The drop pipe should terminate at its lower end with a plain or duck-foot bend
turned so as to discharge its flow at 45 degree or less then to the direction of the
flow in the main sewer and the pipe, unless of cast iron, should be surrounded
with 150 mm of concrete.
In the case of sewer over 450 mm in diameter the drop in level may be
accomplished by one of the following methods: -

(a) A cascade: - This is a steep ramp composed of steps over which the flow is
broken up and retarded. A pipe connecting the two levels is often concreted
under the steps to allow small flow to pass without trickling over the steps. The
cascade steps maybe made of heavy-duty bricks of class- I quality (IS: 2180-
1985) cement concrete with granolithic finish or dressed granite.

(b) A Ramp: - A ramp maybe formed by increasing the grade of the last length
of the upper sewer to about 45 degrees or by constructing a steeply graded
channel or culvert leading from the high level to the low level sewer. In order to
break up the flow down the ramp and minimize the turbulence in the main
sewer the floor of culvert ramp should be obstructed by raced transverse ribs of
either bricks or concrete at 1.50m intervals and a stilling pool provided at the
bottom of the ramp and

(c) By drop in previous successive manholes instead of providing the total drop
require at the junction manholes, the same may be achieved by giving smaller
deeps in successive manhole preceding the junction manhole. Thus, for
example, if a total drop of 2.4m is required to be given, 0.6m drop maybe given
in each of the previous three manholes and the last 0.6m-drop maybe given at
the junction manhole.

1.4.5 Scraper (Service) Type Manhole: -


All sewers above 450mm diameter should have manhole at intervals for 110 to
120 m of scraper type. This manhole should have clear opening of 1200 X 900
mm at top to facilitate lowering of buckets.

1.4.6 Flushing manholes: -


Where it is not possible to obtain self-cleaning velocities due to flatness of the
gradient specially at the top end of branch sewer which receive very little flow,
it is essential that same form of flushing device be incorporated in the system.
This can be done by making grooves at intervals of 45 to 50m in the main drains
in which wooden planks are inserted & water allow to head up and which will
rush on with great velocity when the planks are removed. Alternatively, an
overhead water tanks is built, from which connection are made through pipe
flushing hydrants to rush water to the sewer. The relevant Indian standard is :IS

182
4111(part two).Flushing can be very conveniently accomplished by use of fire
hydrant or tanker.

Where flushing manhole is provided, they are located generally at the head of a
sewer. Sufficient velocity shall be imparted in the sewer to wash away the
deposited solid. The flush is usually effective up to a certain distance after
which the imparted velocity gets dissipated.

The automatic systems which are operated by mechanical units gets often
corroded by the sewer gases and do not generally function satisfactorily and
hence are not recommended. In case of hard chock ages in sewers, care should
be exercised to be ensuring that there is no possibility or back flow of sewer
into the water supply mains.
Approximate quantities of water needed for flushing are as follows: -

S.No. Slope Quantity of water (litres)


200mmdia 250mmdia 300mmdia
1. 0.00502300 2500 3000
2. 0.00751500 1800 2300
3. 0.01001300 1500 2000
4. 0.0200500 800 1000
5. 0.0300400 500 700

2. Constructional Details: -
Manhole is usually constructed directly over the centre line of the sewer they
are usually constructed with brickwork. However in areas where sewers are to
be laid in high water condition manhole shall be constructed in R.C.C. They are
circular, rectangular or square in shape. Manholes should be of such size as will
allow necessary cleaning and inspection of manholes.

(a) Rectangular Manholes - The minimum internal sizes of rectangular manholes


between brick face should be as follows:
(I) For depth of manholes less than 0.9m, 900mm x 800mm and
(ii) For depths of manholes from 0.9mm and upto 2.5m, 1200mm x 900mm

(b) Arch type manholes - For depth of 2.5m and above, arch type manholes can
be provided and the internal size of the chambers between brick faces shall be
1400mm x 900mm. The width of manhole chamber on bents and junction of
pipes with diameter greater than 450mm should be suitably increased to 900mm
or more so that benching width on either side of the channel at-least 200mm.

3. Circular manholes -
Circular manholes are longer than rectangular and arch type manhole and thus
there are preferred over rectangular as well as arch type manholes. The circular
manholes can be provided for all depths starting from 0.9m circular manholes are
straight down in lower portion and slanting in top portion so as to narrow down

183
the top opening equal to internal dia.of manhole over. Depending upon the depth
of manhole, the diameter of manhole changes. The internal diameter of circular
manholes may be kept as following for verifying depths.

(I) For depths 0.9m and up to 1.65mm, 900mm diameter.


(ii) For depths above 1.65m and up to 2.30m, 1200mm diameter.
(iii) For depths above 2.30m and up to 9.0m, 1500mm diameter.
(iv) For depths above 9.0m and up to 14.0m, 1800mm diameter.

Typical circular manholes are shown in fig.6

If the sewer is constructed in a tunnel, the manhole should be located at the


access or working shaft and the manhole chamber maybe constructed of a size
to suit the working shaft or vice-versa.

The width /diameter of the manhole should not be less than internal diameter of
the sewer +150mm benching as both sides (150mm+ 150mm) The opening for
entry into the manhole (without cover) should be such minimum diameters as to
allow a workman with the cleaning equipments into the interior of the manhole
without difficulty. A minimum clear opening of 60cm preferably circular is
recommended. Suitable steps usually cast iron shall be provided for entry.

Access shaft for large sewers - Access shaft shall be circular in shape and shall
have a minimum internal dia of 750mm, where the depth of the shaft exceeds
3m suitable dimensions shall be provided to facilitate cleaning and
maintenance.

Access shaft where built of brick work should be carvel led on three sides to
reduce it to the size of the opening in the cover frame, and to provide easy
access on the fourth side to step iron or ladder .In determining sizes the
dimensions of the maintenance equipments likely to be used in sewer, shall be
kept in view.

Where the diameter of the sewer is increased, the crown of the entering leaving
pipes shall be fixed at the same level and necessary slopes given in the inverted
of the manholes chamber .In exceptional cases and where unavoidable the
crown of the entering sewer maybe fixed at lower level but in each cases too the
peak flow level of the two sewer shall be kept the same.

A slab generally of plain cement concrete at least 150mm thick should be


provided at the base to support the walls of the manhole and to prevent the entry
of foul water. The thickness of the base also shall be suitably increased up to
300mm, for manholes on large dia sewers, with adequate reinforcement
provided to withstand excessive uplift pressures. In the case of larger manholes,
the flow in the sewer should be carried in U-Shaped smooth channel constructed
integrally with the concrete base of the manhole. The side of the channel should
be equal to the dia. of the largest sewer pipe. The adjacent floor should have a

184
slope of 1 in 10 draining to the channel. Where more than one sewer enters the
manhole the flow through channel should be curved smoothly and should have
sufficient capacity to carry the maximum flow.

It is desirable to place the first pipe joint outside the manhole as close as
practicable. The pipe shall be built inside the wall of the manhole flush with the
internal periphery protected with an arch of masonry or cement concrete to
prevent it from being crushed.

The sidewalls of the manhole are usually constructed of cement brickwork


250mm thick and corbelled suitably to accommodate the frame of the manhole
cover.

The inside and outside of the brickwork should be plastered with cement mortar
1:3 (1 cement: 3 coarse sand) and inside finished smooth with a coat of neat
cement.

Where subsoil water condition exist, a richer mix may be used and it shall
further be water proofed with addition of approved water proofing compound in
a quantity as per manufacturer's specifications.

4 Covers and frames: -


The size of manhole covers should be such that there should be clear opening of
not less than 560mm diameter for manholes exceeding 0.9m depths. When cast
iron manhole covers and frames are used they shall confirm to IS 1726 (parts 1
to 7). The frames of manhole shall be firmly embedded to correct alignment and
level in plain concrete on the top of masonry. After completion of the work,
manhole covers shall be sealed by means of thick grease.
Where sewer are to be laid in high subsoil water conditions, manholes maybe
constructed in R.C.C. of grade M 20 or 1:1.5:3. The manholes in this type of
construction shall be preferably circular.

Heavy reinforced concrete covers with suitable lifting arrangements could also
be used instead of C.I manhole covers. However pre-cast cement concrete
covers reinforced by materials other than mild steel should be used provided
that those are properly tested & certified for use by competent authority. Fibre
reinforcement plastic covers (FRP) conforming to relevant IS: may be used
wherever such covers are available.

185
5. Inverted siphon

5.1 Function and provision


In the course of laying sewers, at times it is found necessary to cross
obstructions like nallah etc. Such obstruction shall be crossed by means of
"Inverted Syphon” i.e. by laying the sewer under the obstruction and regaining
as much elevation as possible after the obstruction is passed .As the siphons are
depressed below the hydraulic grade line, maintenance of self cleaning velocity
at all flows is very important. Two considerations, which govern the profile of a
siphon, are provision for hydraulic losses and case of cleaning.

5.2. Construction
To ensure self-cleaning velocities for the wide variations in flows, generally,
two or more pipes not less than 200mm dia are provided in parallel so that up to
the average flows, first pipe is used and when the flow exceeds the average, the
second and subsequent pipes take the balance flow. Siphons may need cleaning
other than gravity sewers and hence should not have any sharp bends either
horizontal or vertical. Only smooth curves of adequate radius should be used.
The design criteria for inverted syphons are given in IS: 411 part -III. It is
necessary to have a self-cleaning velocity of 1.0 mps for the minimum flow to
avoid deposition in the line.
Provision should be made for isolating the individual pipes as well as the siphon
to facilitate cleaning.
It is desirable to provide a course screen to prevent the entry of rags etc, into
the siphon.

5.3. Inlet and outlet chambers: -


In the multiple pipe siphon, the inlet should be such that the pipes coming to
action successively as the flow increases. This may be achieved by providing
lateral with heights kept in accordance with the depth of flow at which one or
more siphon pipes functions. In the two-pipe siphon, the first should take 1.25
to 1.5 times the average flow and second should take the balance of the flow.

A manhole at each end of the siphon should be provided with clearance for
rodding. The design of inlet and outlet chambers should allow sufficient room
for entry for cleaning and maintenance of siphons. The outlet chambers should
be so designed as to prevent the flow of sewage into pipes, which are not being
used at the time of minimum flow.

6. Hatch box:
Hatch boxes of adequate size in manholes shall be provided on the pipes so as
to give access into the pipes for rodding.

186
7. By pass:
Proper by pass arrangements should be provided from the inlet chamber and if
required special arrangements should be made for pumping the sewage to the
lower reach of sewer line. Alternatively a vacuum pump maybe provided at the
outlet to overcome maintenance problems arising out of dogging and silting of
siphons. If it is possible a blow off may be installed at the low point to facilitate
emergency maintenance operations.
8 storm water inlets :-
There are device meant to admit the surface runoff to the sewers and form a
very important part of the systems. Their location and design should therefore
be given careful considerations.
Storm water inlets maybe categorised under three major groups viz. curb inlets,
gutter inlets and combination inlets, each being either depressed or flush
depending upon their elevation with reference to the pavement surface.
The actual structure of an inlet is usually made of brickwork. Normally cast-iron
gratings conforming to IS : 5961 shall be used . In case there is no vehicular
traffic, fabricated steel gratings maybe used. The clear opening shall not be
more than 25mm. The connecting pipe from the street inlet to the main street
sewer should not be less than 200mm in dia. and should have sufficient slope.
Maximum spacing of inlets would depend upon various conditions of road
surface, size and type of inlet and rainfall. A maximum spacing of 30m is
recommended.
9. Sewer ventilators :-
In a modern, well designed sewerage system, there is no need to provide
ventilation on such elaborate scale considered necessary in the past, especially
with the present day policy to omit intercepting traps in house connections. The
ventilating columns/shafts are not necessary where intercepting traps are not
provided. It is necessary however, to make provision for the escape of air to
take care of the exigencies of full flow and also to keep the sewage as fresh as
possible especially in outfall sewers. In case of storm sewers providing
ventilating manhole covers can do these.

9.1 Provision: -
Ventilating columns/ shafts shall be provided at an internal of 180m in all mains
intercepting and outfall sewers, near the manholes.
The connections of house drains to the sewer shall be allowed without the use
of any intercepting trap and thus permitting ventilation of laterals and branch
sewers via. House drains and their ventilating pipes.

187
9.2. Construction: -
The ventilating shaft shall consist of vertical columns of R.C.C. or cast iron
about 6 to 8 metre in height and about 100 to 150mm in diameter (opening) at
the top, the diameter increasing uniformly towards the bottom for stability. The
shaft shall be provided with a Crowell or fitted with a wire ground at the top.

10. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

188
SEWER APPURTENANCES

S.No. Items Unit Rate


(Rs.)
15.1 Providing and fixing SW gully trap complete with
CI grating, Brick masonry chamber in cement
mortar 1:5 (1 cement :5 fine sand) water tight CI
cover with frame of 30x30cm size including
necessary Excavation, cement concrete CC 1:5:10
(1 cement: 5 fine sand: 10 graded stone aggregate 40mm
size),CC 1:2:4(1cement:2coarse sand:4 graded stone
aggregate 20mm nominal size ) for fixing CI cover
with frame,12 mm thick cement plaster 1:2 (1
cement:2 coarse sand ) finished with a floating coat of
neat cement complete.

15.1.1 100x100mm size "P" Gully Trap Chamber Each 1850.00

15.1.2 125x100mm size "P", "Q" or "S" type Gully trap Each 1927.00
chamber
15.1.3 180x150mm size "P" or "S" type Each 2019.00

MAN HOLES

15.2 Constructing Brick Masonry Manhole in Cement


Mortar 1 :4 (1 cement : 4 fine sand) R.C.C. top slab
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size), foundation concrete
1:4:8 mix (1cement : 4 coarse sand : 8 graded stone
aggregate 40mm nominal size) inside plastering 12mm
thick with cement mortar 1:3 (1cement : 3 fine sand)
finished with a floating coat of neat cement and
making channels in CC 1:2:4 (1 cement : 2 coarse sand
: 4 graded stone aggregate 20mm nominal size) including
finishing the channel to shape, curing etc. (
Excavation foot rest and external cement plaster
shall be paid for separately)
15.2.1 Inside size 90x80 cm and 45 cm deep including CI Each 9468.00
cover with frame 455x610 mm internal dimensions
total weight of cover and frames to be not less than
( 23+15) 38 kg .
15.2.2 Inside size 90x80 cm and 60 cm deep including CI Each 10266.00
cover with frame 455x610mm internal dimensions
total weight of cover and frames to be not less than
(23+15) 38 kg

189
S.No. Items Unit Rate
(Rs.)
15.2.3 Inside size 120x90 cm and 90 cm deep Manhole Each 20434.00
including CI cover with frame ( medium duty ) 500
mm internal diameter total weight of cover and
frame to be not less than (58+58) 116 kg.
15.2.4 Inside size 120x90 cm and 90 cm deep Manhole Each 27334.00
including CI cover with frame ( Heavy duty ) 560
mm internal diameter total weight of cover and
frame to be not less than (108+100) 208 kg.
15.2.5 Manhole for property ( House ) connection

(i) Inside size 60x60 cm and 90 cm deep manhole with Each 7986.00
fixing of ISI marked pre cast RCC manhole cover
& frame i/c transportation etc. 600x600 mm size
heavy duty .
(ii) Inside size 60x45 cm and 60 cm deep manhole with Each 6053.00
fixing of ISI marked pre cast RCC manhole cover
& frame i/c transportation etc. 600x450 mm size
heavy duty
15.3 Extra for depth up to 1.00 m for man holes over
item 15.2
15.3.1 90x80cm size manhole over item per 5321.00
meter
15.3.2 120x90cm size manhole over item. per 6358.00
meter
15.3.3 60x60cm size manhole over item per 4024.00
meter
15.3.4 60x45 cm size manhole over item per 3635.00
meter
15.4 Constructing Brick Masonry Circular Man Hole
1500 mm internal dia at bottom & 560 mm dia at
top in cement Mortar 1:4 (1 cement: 4 fine sand),
inside Cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 fine sand) finished with a
floating coat of neat cement, foundation concrete
20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size ) and
making channels in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) finished with a floating coat of neat cement
etc. all complete.

190
S.No. Items Unit Rate
(Rs.)
15.4.1 For one manhole upto 2650 mm deep with fixing Each 25490.00
of 560 mm dia ISI marked reinforcement cement
concrete cover & frame heavy duty including
transportation etc. in cement concrete 1:2:4 all
complete.
( Excavation, foot rests & cement plaster at the
15.4.2 external
For one surface
manholeshall
uptobe2650
paid for
mmseparately
deep with) fixing Each 31942.00
of 560 mm dia CI cover & frame (medium duty)
weight not less than (58+58) 116 kg. including
transportation etc. in cement concrete 1:2:4 all
complete.
( Excavation, foot rests & cement plaster at the
15.5 external
Extra forsurface
depthshall
for be paid for
circular separately
manholes ) item
over
15.4
15.5.1 Depth 2.65m to 4.25 m per 10196.00
meter
15.5.2 Depth 4.25m to 9.75m per 14020.00
meter
15.6 Constructing Brick Masonry Circular Man Hole
1200 mm internal dia at bottom & 560 mm dia at
top in cement Mortar 1:4 (1 cement: 4 fine sand),
inside Cement plaster 12 mm thick with cement
mortar 1:3 (1 cement : 3 fine sand) finished with a
floating coat of neat cement, foundation concrete
20 cm thick in 1:3:6 ( 1 cement : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size ) and
making channels in cement concrete 1:2:4 (1 cement
: 2 coarse sand : 4 graded stone aggregate 20mm nominal
size) finished with a floating coat of neat cement
etc. all complete.
15.6.1 For one manhole upto 1650 mm deep with fixing Each 16126.00
of 560 mm dia ISI marked reinforcement cement
concrete cover & frame heavy duty including
transportation etc. in cement concrete 1:2:4 all
complete.
( Excavation, foot rests & cement plaster at the
15.6.2 external
Add extrasurface shall1.65
for depth be paid for mtr.
to 2.30 separately) Per 6450.00
Mtr.

191
S.No. Items Unit Rate
(Rs.)
15.7 Constructing Brick Masonry Circular Man Hole
900 mm internal dia at bottom & 560 mm dia at top
in cement Mortar 1:4 (1 cement: 4 fine sand), inside
Cement plaster 12 mm thick with cement mortar
1:3 (1 cement : 3 fine sand) finished with a floating
coat of neat cement, foundation concrete 20 cm
thick in 1:3:6 ( 1 cement : 3 fine sand : 6 graded stone
aggregate 40 mm nominal size ) and making channels
in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) finished
with a floating coat of neat cement etc. all
complete.
15.7.1 For one Manhole 900mm deep with fixing of 560 Each 11727.00
mm dia ISI marked reinforcement cement concrete
cover & frame heavy duty including transportation
etc. in cement concrete 1:2:4 all complete.
( Excavation, foot rests & cement plaster at the
external surface shall be paid for separately)
15.7.2 Add extra for depth 0.90 to 1.65 mtr. Each 4691.00
15.8 Providing MS foot rests i/c fixing in manhole with
20x20x10cm CC blocks of 1:3:6 (1 cement:3 coarse
sand : 6 graded stone aggregate 20mm nominal size )

15.8.1 With 20mm square bar foot rest Each 255.00

15.8.2 With 20mm round bar foot rest Each 225.00

15.9 Making connection of drain or sewer line with


existing service lines Manhole including breaking
into and making good the walls, floors etc. with
cement concrete 1 :2:4 ( 1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size), cement
plastered with CM 1:3(1 cement : 3 coarse sand)
finished with a floating coat of neat cement and
making necessary channels etc. complete.
15.9.1 For 100 to 200 mm dia pipes Each 347.00
15.9.2 For 250 to 300 mm dia pipes Each 398.00
15.9.3 For 350 to 450 mm dia pipes Each 650.00

192
S.No. Items Unit Rate
(Rs.)
15.10 Providing SCI (Sand Cast Iron) drop connection
with SCI (Sand Cast Iron) drop pipe and bend
encased alround with CC 1:5:10 (1 cement: 5
coarse sand: 10 graded stone aggregate 40 mm
nominal size) including cutting holes and making
good with brick work in cement mortar 1:5 (1
cement:5 fine sand) plastered with cement mortar 1:3
(1 cement: 3 fine sand ) on inside walls including lead
caulked joints and jointing SW pipes & SCI pipes
with stiff cement mortar 1:1(1 cement: 1fine sand)
including making required channel etc. complete.
15.10.1 100 mm dia Sand cast iron drop connection Each 4667.00
15.10.2 150 mm dia Sand cast iron drop connection Each 7001.00
15.10.3 Extra rate shall be payable for depths of drop more
than 60 cm
(i) 100 mm dia Sand cast iron drop connection Per 1400.00
mtr.
(ii) 150 mm dia Sand cast iron drop connection Per 2100.00
mtr.
15.11 Road Gully Chambers
Construction of Brick masonry road gully chambers
with brick work in cement mortar 1:5 (1 cement: 5
fine sand ) and 12mm thick plaster in cement mortar
1:3 including foundation concrete 1:5:10 (1 cement
:5 coarse sand :10 graded stone aggregate 40mm nominal
size ) including excavation etc. complete.
15.11.1 Chamber 45x45x77.5cm with vertical grating each 4304.00
450x100 mm
15.11.2 Chamber 50x45x60cm with horizontal grating each 3814.00
500x450 mm
15.11.3 Chamber 110 x 50 x 77.5cm with horizontal 500 x each 6667.00
450 mm and vertical gratings 450x100 mm both.
REPAIRING
15.12 Dismantling of manhole including R.C.C./C.C. top
slab, CI / pre cast RCC cover with frame including
stacking of useful materials near the site and
disposal of unserviceable materials into municipal
dumps within 50 m lead
15.12.1 Manhole size 90x80 and 45 cm deep Each 832.00
15.12.2 Manhole size 90x80 and 60 cm deep Each 918.00
15.12.3 Manhole size 120x90 and 90 cm deep Each 1375.00
15.12.4 Manholes size 60x45 and 60 cm deep. Each 450.00
15.12.5 Manholes size 60x60 and 90 cm deep. Each 653.00

193
S.No. Items Unit Rate
(Rs.)
15.12.6 Extra for depth of manholes dismantling
(i) Manhole size 90x80 cm, depth above 60 cm Per 528.00
Mtr.
(ii) Manhole size 120x90cm, depth above 90 cm Per 629.00
Mtr.
(iii) Manholes size 60x45 cm, depth above 60 cm Per 371.00
Mtr.
(iv) Manholes size 60x60 cm, depth above 90 cm Per 409.00
Mtr.
15.12.7 Manhole 1.50 m dia circular and upto 2.65 m deep Each 2872.00
15.12.8 Manhole 1.20 m dia circular, and upto 1.65 m deep Each 1788.00
15.12.9 Manhole 0.90 m dia circular and upto 0.90 m deep Each 1080.00
15.12.10 Extra for depth of manholes dismantling
(i) Manhole 1.50 m dia circular, depth 2.65 to 4.25m Per 1149.00
Mtr.
(ii) Manhole 1.50 m dia circular, depth 4.25 to 9.75m Per 1580.00
Mtr.
(iii) Manhole 1.20 m dia circular, depth 1.65 to 2.30 m Per 715.00
Mtr.
(iv) Manhole 0.90 m dia circular, depth 0.90 to 1.65m Per 432.00
Mtr.
15.13 Replacement of M.S. Foot rests in manhole
including dismantling concrete block and fixing
with 20x20x10 cm C.C. blocks of 1:3:6 (1 cement :
3 coarse sand : 6 graded stone aggregate 20mm nominal
size)
15.13.1 With 20mm square bar foot rest. Each 284.00
15.13.2 With 20mm round bar foot rest. Each 255.00
15.14 Pumping out to remove the sewers blockages by Per 215.00
using suitable pump sets operated by generators , Hours
whole assembly mounted on two/four wheels trailer
/pickup van. Including diesel & labour charges etc.
15.15 Providing and fixing in position Cast Iron Kg. 75.00
Manhole Covers and frame conforming to IS 1726.
All exposed edges rounded end finished in cement
mortar etc. complete.
15.16 Labour only for fixing in position Cast Iron Kg 5.00
Manhole Covers & frame conforming to IS-1726.
15.17 Providing & fixing of ISI marked pre cast
reinforced cement concrete manhole cover
including frame and transporting at site, cost of
all material etc.
15.17.1 500 mm dia extra heavy duty Each 2636.00

194
S.No. Items Unit Rate
(Rs.)
15.17.2 560 mm dia extra heavy duty Each 2836.00
15.17.3 600 mm dia extra heavy duty Each 3236.00
15.17.4 500 mm dia heavy duty Each 1986.00
15.17.5 560 mm dia heavy duty Each 2336.00
15.17.6 600 mm dia heavy duty Each 2586.00
15.17.7 600 x 900 mm size extra heavy duty Each 4536.00
15.17.8 600 x 900 mm size heavy duty Each 3986.00
15.17.9 450 x 900 mm size heavy duty Each 3536.00
15.17.10 600 X 600 mm size extra heavy duty Each 3236.00
15.17.11 600 X 600 mm size heavy duty Each 2486.00
15.17.12 600 X 600 mm size medium duty Each 2036.00
15.17.13 600 X 450 mm size heavy duty Each 2286.00
15.17.14 600 X 450 mm size medium duty Each 1936.00
15.17.15 450 X 450 mm size heavy duty Each 1736.00
15.17.16 450 X 450 mm size medium duty Each 1436.00
15.18 Providing & fixing of ISI marked pre cast
reinforced cement concrete manhole cover
without frame and transporting at site, cost of
all material etc.
15.18.1 500 mm dia extra heavy duty Each 1630.00
15.18.2 560 mm dia extra heavy duty Each 1930.00
15.18.3 600 mm dia extra heavy duty Each 2230.00
15.18.4 500 mm dia heavy duty Each 1280.00
15.18.5 560 mm dia heavy duty Each 1630.00
15.18.6 600 mm dia heavy duty Each 2030.00
15.18.7 600 x 900 mm size extra heavy duty Each 3930.00
15.18.8 600 x 900 mm size heavy duty Each 3630.00
15.18.9 450 x 900 mm size heavy duty Each 2730.00
15.18.10 600 X 600 mm size extra heavy duty Each 1980.00
15.18.11 600 X 600 mm size heavy duty Each 1830.00
15.18.12 600 X 600 mm size medium duty Each 1280.00
15.18.13 600 X 450 mm size heavy duty Each 1580.00
15.18.14 600 X 450 mm size medium duty Each 1050.00
15.18.15 450 X 450 mm size heavy duty Each 1080.00
15.18.16 450 X 450 mm size medium duty Each 880.00

195
CHAPTER XVI

ALLIED CIVIL WORKS

196
CHAPTER XVI
ALLIED CIVIL WORKS

Excavation And Preparation Of Trench

1. The rates for various items of civil works given in this chapter shall be
applicable for the civil works connected with laying and jointing of water
supply and sewerage pipeline works only. These rates shall not be applicable
for the items of civil works for which the rates has already given in the
relevant chapters.

2. The trenches shall run in perfectly straight line between points or manholes,
as shown on the approved drawings.

3. The excavation of the trench shall be commenced at the downstream end of


the sewer and be continued up the gradient.

4. The trench shall be excavated only so far in advance of pipe laying as


specified by the Engineer in Charge. It shall usually be so regulated as to
enable the excavation to be completed about one day in advance of pipe
laying.

5. The trench shall be so shored and drained that the workmen may work there
in safely and efficiently.

6. The trench shall be kept free from water. Excavation below water table shall
be done after dewatering trenches. The discharge of the trench dewatering
pumps shall be conveyed either to discharge channels or to natural drains.

7. The excavation shall be carried out with manual labour or with suitable
mechanical equipment as approved by the Engineer in charge.

8. When the pipeline is under a roadway, a minimum cover of 100 cm is


recommended for adoption but it may be modified to suit local conditions
and in case of A.C. pipe a cover of at least 1.25 m is provided. Where the
pipe line or drains crosses the road, the road crossing shall be excavated half
at a time, the 2nd half being, commenced after the pipes have been laid in
the 1st half and the trench refilled. Necessary safety measures for traffic as
directed shall be adopted. All water mains; cables and any other such
services etc. met within the course of excavation shall be carefully protected
and supported. Care shall be taken not to disturb the electrical and
communicator cable met with during course of excavation, removal of
which if necessary shall be arranged by the engineer in charge.
9. Trench shall be of sufficient width to provide a free working space on either
side of pipe. At the bottom between the faces, it shall be such as to provide
not less than 200mm clearance on either side of pipe. Additional width shall

197
have to be provided at position of sockets, flenges, D.Joints for jointing.
Depth of pit at such places shall also be sufficient to permit finishing of
joints.

10. In obtaining the formation of the bottom of the trenches in case of sewer
line, the usual method of using sight rails and boning rods shall be adopted
during the whole of the process. The sight rails shall be fixed at all changes
of direction or gradient and at suitable intervals, which may not be more
than 15 meters apart, before excavation is started. The centre line shall be
marked on each horizontal rail, which is fixed at true level.

11. The excavation shall be boned in at least once in every 2 meters, the foot of
the boning rod being set on a block of wood of the exact thickness of the
material of the pipes.

12. Except where special foundations are to be provided, the trench shall be
excavated in accordance with one of the following alternatives as may be
considered appropriate by the Engineer in charge.

(a) The trench shall be excavated to the exact gradient specified so that
no making of the sub grade by back filling is required and the
concrete bed, where required, may be prepared with greatest ease
giving a uniform and continuous bearing and support for the pipe

(b) When the bottom of the trench at the specified gradient is found to be
unstable or to include ashes and cinders, all types of refuse, vegetable
or other organic material, or large pieces or fragments of inorganic
material, they shall be removed to the satisfaction of the Engineer in
charge. Before laying the concrete bed, where necessary, the specific
gradient shall be attained by back filling with an approved material in
compacted layers of 8 cm. The layers shall then be tamped as
directed by the Engineer in Charge.

(c) The bed of the trench, if in soft or made up earth, shall be well
watered and rammed before laying the pipes and the depression. If
any shall be properly filled with approved earth and consolidated in
20 cm layer.

(d) The bed of the trench, if in B.C. Soil, shall be excavated 20cm more
than the normal depth and then filled up by moorum or granular
material.

13. If the sides of the trench are not vertical the toes of the side slopes shall end
at the top of the pipe and practically, vertical sided trench shall be dug from
these down to the sub grade.

198
14. The bottom of the trench shall be properly trimmed off to present a plain
surface and all irregularities shall be levelled.

15. Where rock and large stone or boulders are encountered the trench shall be
trimmed to a depth of at least 8 cm below the level at which the bottom of
the barrel of the pipe is to be laid and the trench brought back to the required
grade by filling with selected fine sand broken stone (passing sieve of
12.5mm aperture size) and compacted so as to provide a smooth bedding for
the pipes.

16. After the Excavation of the trench is completed hollows shall be cut at
required position to receive the socket of the pipe and these hollows shall be
of sufficient depth to ensure that the bearer of the pipe shall rest throughout
their entire length on the solid ground and that sufficient space left for
joining the under side of the pipe joint. These socket holds shall be refilled
with sand after joining the pipe.

17. Where the bottom of the trench at sub grade is found to consist of material
which is unstable to such a degree that, in the opinion of the Engineer in
charge, it cannot be removed and replaced with an approved material
thoroughly compacted in place to support the pipe properly, a suitable
foundation for the consist of piling, timbers or other materials, in accordance
with plan prepared by the Engineer in Charge shall be constructed.

18. Trench excavation in rock in inhabited areas should be done by hammering


and chiselling or other appropriate mechanical means but not by blasting.

19. Excavation for trenches in rock by blasting shall be permitted only in open
areas, with the written permission of the competent authority, after the
Engineer in charge has satisfied himself that there is no danger to persons or
property if blasting is done in that area. All necessary licenses etc shall be the
responsibility of the contractor.

20. Proper precautions shall be taken for the protection of persons or property
during blasting by the contractor after obtaining necessary permission for
blasting from the concerned authorities..

21. The hours of blasting shall be fixed by the Engineer in charge in consultation
with the concerned local authorities.

22. The procedure of blasting shall conform to the requirements of local


administration controlling authorities.

23. Open cut deep trenches in bad ground shall be sheeted and braced as
required by local municipal regulations and as may be necessary to protect
life, property or the work. Payment shall be regulated as per terms of the
agreement.

199
24. When close sheeting is required, it shall be so driven as to prevent adjacent
soil from entering the trench either below or through such sheeting for which
no extra payment shall be made.

25. Engineer in charge shall have the right to order the sheeting to be driven to
the full depth of the trench or to such additional depths as may be required
for the protection of the work, as per manual on water supply and sewage
and sewage treatment (1993 Second edition) for which no extra payment
shall be made.

26. Where the soil in the lower limits of a trench has the necessary stability, the
Engineer in charge at his discretion, may permit stopping of the driving of
sheeting at some designated elevation above the trench bottom for which no
extra payment shall be made.

27. Sheeting done in trenches near heavy or important buildings shall be left in
ground, if any settlement of the buildings is anticipated as per direction of
Engineer in Charge and for which no extra payment shall be made.

28. Sheeting and bracing which have been ordered left in place should be
removed for a distance of 90 cm. below the established street level or the
existing surface of the street whichever is lower for which no extra payment
shall be made.

29. Trench bracing, except that which has been left in place may be removed
after the back filling has been completed or has been brought up to such an
elevation as to permit its safe removal for which no extra payment shall be
made.

30. Sheeting and bracing may be removed before filling the trench, but only in
such manner as will ensure the adequate protection of the completed work
and adjacent structures.

31. All surface materials which in the opinion of the Engineer in charge, are
suitable for reuse in restoring the surface, shall be kept separate from the
general excavation material as directed by the Engineer in charge.

32. The excavated material shall be not placed within one meter or half of the
depth of the trench, whichever is greater, from the edge of the trench. The
excavated material shall be separated and stacked so that in refilling it may
be re laid and compacted in the order to the satisfaction of the engineer in
charge.

33. (a) If the hard rock is found throughout the depth, then the trench after pipe
laying should be filled up with good excavated earth except B.C. soil, if
available within 50m lead, on either side of pipe and up to 30cm above

200
the pipe and remaining depth shall be filled up with excavated hard
rock. The balance hard rock shall be compulsorily issued to the
contractor at such issue rate, which are specified in the contract
agreement after maintaining proper M.A.S. account. If good soil and
hard rock in excavation is obtained, then suitable action as explained
above shall be taken accordingly.
If hard rock in excavation is obtained throughout the length and no
good soil is obtained on either side within 50m of excavation then it
shall be filled up by moorum and payment shall be made as per item
No. 16.11. In this case overall rock shall be compulsorily issued at the
rate of Rs 170 per cum to be specified in the contract agreement after
maintaining proper M.A.S. account. Payment shall be regulated as per
terms of agreement at appropriate rate.

(b) In case of B.C. soil the side of pipe and filling above 30 cm of pipe
shall be done by moorum and balance depth shall be filled up by
excavated B.C. Soil.
34. Hydrants under pressure, surface boxes, fire or other utility controls shall be
left unobstructed and accessible until the work is completed.
35. Gutters shall be kept clear or other satisfactory provisions made for street
drainage and natural watercourses shall not be obstructed.
36. To protect person from injury and to avoid danger to property, adequate
barricades, construction signs, torches, red lanterns and guards as required
shall be placed and maintained during the progress of the construction work
and until it is safe for traffic to use the road way.

37. All materials, piles, equipment and pipe which may serve as obstructions to
traffic shall be enclosed by fences or barricade and shall be protected by
proper lights when the visibility is poor.

38. The rules and regulations or the local authority regarding safety provisions
shall be observed.

39 The work shall be carried in such a manner, which will cause the least
interruption to traffic, and the road or street may be closed in such a manner
that it causes the least interruption to the traffic.

40 Where it is necessary for traffic to cross open trenches, suitable cross over
planks shall be provided.

41 Suitable signs indicating that a street is closed shall be placed and necessary
detour signs for the proper maintenance of traffic shall be provided.

42 Temporary support, adequate protection and maintenance of all underground


and surface structure, drains, sewers and other obstructions encountered in
the progress of the work shall be provided under the direction of the
Engineer in charge.

201
43 The structure, which may have to be disturbed, shall be restored upon
completion of the work.

44 Trees, shrubbery, fences, poles and all other property and surface structures
shall be protected unless their removal is shown on the drawing or authorised
by the Engineer in charge.

45 Root of trees within a distance of about 0.5m from the site of the pipeline
shall be removed or killed for which no extra payment shall be made.

46 No valve or other control of the existing serving shall be operated without


the permission of the Engineer in charge.

47 The rates include the element of hire and running charges of all types of
plants, machinery & equipment, required to complete the work, unless
specified otherwise.

48 The rates also include the element of testing of samples of various materials
brought by contractor for use on the work, as well as other necessary test for
item of work as stipulated in the specifications.

49 The work should not be accepted in any case if the contractor fails to
observe the instruction of department regarding testing of material.

50 Before making any payment, it will be responsibility of the officer making


payment to assure that all tests are as per prescribed frequency have been
carried out and found as per requirement.

51 The contractor shall have to provide bound ruled register named as Site
Order Book it shall be kept in the charge of Deptt. Supervisory staff
inspecting officer will enter their remarks in this book which will be noted
by contractor or his authorized representative for compliance and report

As mentioned in para 12.9, the width of excavation shall be as per


specification given in the relevant I.S. Specification. The bottom width,
which shall be kept as minimum required for the work as per ISS and if the
depth of the trench is more the top width shall depend on the angle of repose
for a particular type of soil where the pipe line is to be laid.

52 The rate for cutting and making in the same condition include all lead of the
material and also required work and equipment to complete the work as per
specification and as directed by Engineer incharge.

53 The contractor shall be fully responsible to carry out the work in a most safe
way and he shall be fully liable and responsible for any accidents due to any
reason, during the currency of the contract.

202
II. SPECIFICATION FOR CIVIL WORKS
All the civil works shall be done strictly as per relevant I.S. Specifications
and all the materials shall also confirm to the relevant I.S. Specifications. All
the necessary tests of material and work shall be carried out for each work.
Where applicable, the contractor shall also submit manufacturer's test
certificates for materials to the Engineer in Charge.

Materials Specification
(a) Cement :
Cement to be used in the work shall be any of the following types with prior
approval of Engineer-in-charge.

Ordinary Portland cement 43 or 53 grade confirming to IS : 8112-1489 or


P.P.C. conforming to I.S. : 1489 bearing ISI mark.

(b) Coarse Aggregate :


coarse aggregate consist of clear, hard, strong, dense, nonporous and durable
pieces of crushed stone. They shall not consist pieces of elongated particles
salt, alkali, vegetable matter or other deleterious material.

All coarse aggregate shall confirm to IS:383 & tests for conformity shall be
carried out as per IS:2386 Part I to VIII. The maximum value of flakiness
index for coarse aggregate shall not exceed 35%. The coarse aggregate shall
satisfy the following requirement of grading.

I.S.Sieve Percentage by Weight Passing the Sieve


40mm 20mm 12.5mm
63mm 100 -- --
40mm 95-100 100 --
20mm 30-70 95-100 100
12.5mm -- -- 90-100
10mm 10-35 25-55 40-85
4.75mm 0-5 0-10 0-10

(c) Sand / Fine Aggregate :


Sand shall not contain dust, lumps, soft or flaky materials fine aggregate
having positive alkali silica reaction shall not be used. All fine aggregate
shall confirm to IS : 383. The fineness modulus of fine aggregate shall
neither be less than 2.0 nor greater than 3.5. Sand to be used in work shall
confirm to IS-1542-1960 for plaster and IS-166-1965 for masonry work.
Clay content should not be more than permissible limit.

(d) Water :
Water used for mixing and curing shall be clean and free from injurious
amounts of oils, acids, salts, sugar, organic material or other substances that
may be deleterious to concrete potable water in generally consider
satisfactory for mixing and curing of concrete.

203
(e) Steel :
For R.C.C. works steel to be used shall confirms to IS-1786. All steel be
procured from original producer and no re-rolled steel shall be used in the
work. Only new steel shall be delivered to site. Brittle burnt, defective,
cracked bar shall be discarded.
(f) Concrete :
Normally concrete shall be mixed either in a concrete mixer or in a batching
& mixing plant. Hand mixing is prohibited and under unavoidable
circumstances it should be done only with the prior permission of Engineer-
in-charge. Mixing shall be continue till materials are uniformly distributed
and a uniform colour of entire mass is obtained and each particle of
aggregate shows coating of cement. In no case mixing shall be done for less
than 2 minutes. Concrete shall be transported and placed as near as
practicable to its final position within 30 minutes of its discharge from the
mixer.
(i) Structural steel shall be of tested, standard quality confirming to IS-226-69
and commercial quality shall confirm to IS-1977-69.
(ii) Steel work riveted or bolted shall confirm to IS-1148-1968 and IS-800-1962.
(iii) Welding of steel shall be electric arc welding as per IS-816-1956 and shall
be on the lines given in 800-1962.
(iv) Rolled steel section for fabrication of steel shall confirm to IS-7452-1974.
(v) Rates of steel angle includes all forgoing, reducing to required size, shape
and figure, drilling, tapping, punching etc. and every description of
workmanship that may be necessary to fabricate, finish, erect and fix in
position in perfect manner.
(g) Bricks :
(i) The brick work shall be carried out as per relevant I.S. Specifications and the
drawing, specification and direction by the Engineer-in-charge.
(ii) Burnt clay bricks shall confirm to the requirement of IS-1077. They shall be
free from cracks and flaws and nodules of free lime. The brick shall have
smooth rectangular faces with sharp edges and corners.
(iii) Cement mortar for work shall be as per the relevant specification.
(iv) All bricks shall be thoroughly socked in tank filled with water for minimum
period one hour prior to being laid Such socked bricks shall be stacked on a
clean place where they are not contaminated with earth / dirt etc.
(v) The thickness of joint shall not exceed 10mm
(vi) The Brick work shall be built in uniform layers.
(vii) Brick work shall be done true to plumb in specified manner. All courses shall
be laid truly horizontal and vertical joints shall be truly vertical.
(viii) In case of vertical or inclined joints proper bond between old and new
masonry has to ensured by interlocking the bricks.

204
(ix) Green work / fresh work shall be protected from rain by suitable covering
and shall be kept constantly moist on all faces for minimum of 7 days.
(h) MORTAR :
The mortar mixing shall preferably be done in mechanical mixer operated
manually or by power. Hand mixing can be restored to as long as uniform
density of the mix and its strength are assured subject to prior approval of
Engineer-in-charge. Hand mixing operation, if permitted, carried out on
clean water tight platform when cement and sand shall be first mixed dry in
required proportion several times till the mixture is of uniform. Minimum
quantity of water shall be added to bring the mortar to the consistency of still
paste.
Mortar shall be mixed only in such quantity as required for immediate use.
The mortar normally be considered to use within 30 minutes. Mortar after 30
minutes remains unused shall be rejected and removed from site.
(i) PLASTER :
Plastering shall be done where shown on as per drawing. Plastering shall be
started from top and worked down. Wooden screeds 75mm wide and of the
thickness of the plaster shall be fixed vertically 2.5 to 4 mt. apart to act as
gauge and guide in applying plaster. The mortar shall be laid on the wall
between the screeds using the plasters float and pressing the mortar so that
packed joints are properly filled. The plaster shall there be finished off with
a wooden straight edge reaching across the screeds. The straight edge shall
be worked on the screeds with small upward and side ways motion 50mm to
75mm at a time. Finally, the surface shall be finished off with a plasters
wooden float metal floats shall not be used.
Curing shall be commenced as soon as mortar used for finishing has
hardened sufficiently not be damaged during curing. It shall be kept wet for a
period of at least 7 days.
(j) FORM WORK :
(i) Form work shall include all temporary form for forming concrete of shape
with all props, staging, centring required for support.
(ii) All material shall confirm to relevant I.S. specifications
(iii) Form work shall be constructed with metal or timber, for metal all bolts
should be counter sunk.
(iv) The form work should be robust and strong and joint shall be leak proof,
staging must have cross bracing and diagonal bracing in both direction.
(v) The rates include provision of gradient in form work for terrace roof and
gradient shall be provided necessarily for water drained out quickly and
effectively. Concrete shall not be freely dropped into place from height
exceeding 1.50 mt. And it shall be compacted in its final position within 30
minutes of its discharge from mixer. It shall be compacted thoroughly by
vibration or other means during placing so as to produce a dense
homogenous void free mass having required surface finish.

205
This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.

206
ALLIED CIVIL WORKS

S.No. Items Unit Rates in


Rs.
EXCAVATION
16.1 Surface dressing of the ground including removing 100 1038.00
vegetation and in - equalities not exceeding 15 cm deep Sqm
and disposal of rubbish, lead up to 50 m and lift up to
1.5 m.
All kind of soil
16.2(a) Clearing jungle including uprooting of rank vegetation, 100 535.00
grass, brush wood, trees and saplings of girth up to 30 Sqm
cm measured at a height of 1 m above ground level and
removal of rubbish up to a distance of 50 m outside the
periphery of the area cleared.
16.2(b) Clearing grass and removal of rubbish up to a distance 100 274.00
of 50 m outside the periphery of the area cleared. Sqm

16.3 Installation of HDPE pipe by Horizontal Direction


Drilling Method including preparing and setting up the
plant and equipment, making string of new pipe
material, installing new pipe string and making the
system ready for commissioning by HDD operation
including drilling, stringing, reaming and pulling back
the new pipe on the designed bore path alignment,
proper disposal of drilling fluid, as per code of practice
for horizontal direction drilling technique suiting indian
conditions. Required pipes/ specials and other civil
work shall be paid separately-in all types of soils. (This
item shall be executed only after prior permission of
Superintending Engineer)
HDPE pipe of any class-90 mm outer dia Meter 451.00
HDPE pipe of any class-110 mm outer dia Meter 492.00
16.4 Earth work in excavation by mechanical means Cum 140.00
(Hydraulic excavator) / manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10
sqm on plan) including disposal of excavated earth,
lead up to 50 m and lift up to 1.5 m, disposed earth to
be leveled and neatly dressed.
All kind of soil
16.5 For muddy area cum 210.00
16.6 Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10
sqm on plan) including disposal of excavated earth,
lead up to 50 m and lift up to 1.5 m, disposed earth to

207
S.No. Items Unit Rates in
Rs.
be leveled and neatly dressed. Soft rock with or without
blasting or bituminous pavement / cement concrete
road.
(a) In ordinary or Soft rock with or without blasting or 255.00
bituminous pavement / cement concrete road.
(b) Hard rock (requiring blasting.) 436.00
(c) Hard rock requiring chiseling / where blasting is 587.00
prohibited.

16.7 Extra for every additional lift of 1.5m or part there of cum 7.00
over item 16.4 to 16.6.

16.8 Extra for every additional lead up to 50 m or part cum 77.00


thereof over item 16.4 to 16.6.

16.9 Pumping out water caused by springs, tides or river KL 81.00


seepage, broken water mains or drains or the like
16.10 Filling available excavated earth in trenches, plinth cum 37.00
(a) sides of foundation in layers not exceeding 20cm. in
depth including consolidation of each layer by ramming
watering, lead up to 50m and lift up to 1.5m in all kinds
of soils
(b) Filling available excavated earth in trenches, lead up to Cum 24.00
50m and lift up to 1.5m in all kind of soil excluding
watering and ramming.
16.11 Supply & Filling moorum for pipe bedding or over the cum 643.00
(a) pipe ( including supply of moorum )
(b) Supply & Filling crusher stone dust for pipe bedding or cum 882.00
over the pipe ( including supply of crusher stone dust.)

DISMANTLING & DEMOLISHING

16.12 Demolishing Brick work in lime or cement mortar in Cum


any mix including stacking of serviceable material and 629.00
disposal of unserviceable material with in 50 meter lead
as per direction of engineer-in-charge.
( In cement mortar)
16.13 Demolishing stone rubble masonary manually/ Cum 354.00
mechanical means including stacking of serviceable
material and disposal of unserviceable material with in
50 meter lead as per direction of engineer-in-charge.( In
lime mortar)
208
S.No. Items Unit Rates in
Rs.
16.14 Demolishing stone rubble masonary manually/ Cum 750.00
mechanical means including stacking of serviceable
material and disposal of unserviceable material with in
50 meter lead as per direction of engineer-in-charge.( In
cement mortar )
16.15 Demolishing cement concrete manually / by mechanical
means including disposal of material within 50 m lead
as per direction of engineer-in- charge.

16.15.1 Nominal concrete 1:3:6 or richer mix ( i/c equivalent Cum 745.00
design mix )
16.15.2 Nominal concrete 1:4:8 or Leaner mix ( i/c equivalent Cum 459.00
design mix )
16.15.3 Dismantling of Cement Concrete Pavment by Cum 968.00
mechanical means using pneumatic tools, cutter
breaking to pieces not exceeding 0.02 cum in volume
and stock piling at designated locations and disposal of
dismantled materials up to a lead of 1000 metres,
stacking serviceable and unserviceable materials
separately

16.16 Demolishing R.C.C. work manually / by mechanical Cum 1087.00


means including stacking of steel bars and disposal of
unserviceable material within 50 m lead as per direction
of engineer-in- charge.
16.17 Dismantling old plaster or skirting raking out joints and Sqm 14.00
cleaning the surface for plaster including disposal of
rubbish to the dumping within 50 meters lead.

16.18 Dismantling stone slab flooring laid in cement mortar Sqm 82.00
(a) including stacking of serviceable material and disposal
of unserviceable material within 50 m lead
(b) Dismantling kharanja of any thickness in cement Sqm 63.00
mortar of any mix

REPAIRS TO BUILDING/ ROAD WORK

16.19 Providing & Fixing of stone slab 30 mm thick in Sqm 148.00


(a) cement mortar 1:6 (1 cement 6 sand)
(b) Labour only for Fixing of stone slab 30 mm thick in Sqm 68.00
cement mortar 1:6 (1 cement 6 sand)
(c) Providing & Fixing of Kharanja of any thickness in Sqm. 498.00
C.M. 1:6 ( 1 cement 6 sand )
(d) Labour only for fixing of Kharanja of any thickness. Sqm 132.00

209
S.No. Items Unit Rates in
Rs.
16.20 Cutting of Water bound macadam road and making Cum 1045.00
good the same including supply of extra quantities of
materials i.e. aggregate, moorum screening and labour
required including compaction inlayer by appropriate
methods.
16.21 Cutting of Bituminous road and making good the same Cum 2121.00
including supply of extra quantities of materials i.e.
aggregate, moorum screening and labour required
including compaction inlayer by appropriate methods.

CEMENT CONCRETE

16.22 Providing and laying mechanically mixed cement


concrete with crushed stone aggregate excluding
centering and shuttering (with 40mm nominal size
graded stone aggregate)
(a) In foundation and plinth

i 1:5:10 ( M-5) cum 3472.00


ii 1:4:8 (M-7.5) cum 3682.00

iii 1:3:6 (M-10) cum 3965.00


iv 1:2:4 (M-15) cum 4661.00

(b) In walls & Superstructure up to 4 mt. height above


plinth (with 40mm nominal graded metal)
i. 1:3:6 (M-10) cum 4038.00
ii. 1:2:4 (M-15) cum 4733.00

16.23 Providing & laying mechanically mixed cement


concrete 20mm nominal size graded crushed stone
excluding cost of centering & shuttering.

(a) In Plinth & foundation

i 1:3:6 (M-10) cum 4113.00


ii 1:2:4 (M-15) cum 4695.00
1
iii 1:1 /2:3 (M-20 ) cum 5161.00
iv 1:1:2 (M-25) cum 6385.00

(b) In walls and superstructure up to 4 mt. height above


plinth (with 20mm nominal graded metal)

i 1:3:6 (M-10) Cum 4187.00

210
S.No. Items Unit Rates in
Rs.
ii 1:2:4 (M-15) Cum 4769.00
iii 1:11/2:3 (M-20 ) Cum 5235.00
iv 1:1:2 (M-25) Cum 6458.00

REINFORCED CEMENT CONCRETE

16.24 Providing & laying mechanically mixed R.C.C.


(a) excluding centering & shuttering and reinforcement
in foundation/plinth (20mm graded metal)

i 1:1.5:3 (M 20) cum 4751.00


ii 1:1:2 (M 25) cum 5974.00
iii 1:0.75:1.5 (M 30) cum 6294.00
(b) Providing & laying mechanically mixed R.C.C.
excluding centering & shuttering and reinforcement
in superstructure up to 4 mtr. Height above plinth
level (20mm graded metal)

i 1:1.5:3 (M 20) cum 4787.00


ii 1:1:2 (M 25) cum 6010.00
iii 1:0.75:1.5 (M 30) cum 6331.00

STEEL

16.25 Providing and placing in position cold twisted steel and Kg 55.00
(a) hot rolled deformed steel reinforcement for R.C.C.
work i/c cutting, bending, binding etc. complete i/c cost
of binding wire and wastage.
(b) Structural steel work in single section, fixed with or Kg 59.00
without connecting plate, including cutting, hoisting
fixing in position and applying a priming coat of
approved steel primer all complete.
(c) Structural steel work riveted, bolted or welded in built- Kg 76.00
up section trusses and framed work i/c cutting /hoisting
/fixing in position and applying a priming coat of
approved steel primer all complete.
(d) Steel work in welded built-up section/ framed work,
including cutting hoisting, fixing in position and
applying a priming coat of approved steel primer using
structural steel etc. as required.

211
S.No. Items Unit Rates in
Rs.
(i) In stringers treads landings etc. of stair cases including Kg 79.00
use of chequered plate wherever required all complete.

(ii) In gratings, frames, guard bar, ladder , railings, Kg 97.00


brackets, gates and similar works
Providing and fixing 1mm thick M.S. sheet door Sqm 2892.00
shutters with frame and diagonal braces of 40x40x6
mm angle iron, 3mm M.S. gusset plates at the
junctions and corners i/c all necessary fittings complete
16.26
including applying a priming coat of approved steel
primer. with diagonal braces and central cross pieces of
M.S. angle / flats as required.

CEMENT MORTAR

16.27 Cement Mortar 1:3 (1 Cement : 3 sand) Cum 4671.00


(a)
(b) Cement Mortar 1:4 (1 Cement : 4 sand) Cum 3917.00

(c) Cement Mortar 1:5 (1 Cement : 5 sand) Cum 3451.00

(d) Cement Mortar 1:6 (1 Cement : 6 sand) Cum 3160.00


(e) Cement Mortar 1:8 (1 Cement : 8 sand) Cum 3063.00

BRICK WORK

16.28 Brick work with well burnt chimney bricks having


(a) crushing strength not less than 25 kg/cm² and water
absorption not more than 20 % in foundation & plinth
i/c curing etc. complete.
i. In Cement Mortar 1:3 Cum 5985.00
ii. In Cement Mortar 1:4 Cum 5703.00
iii. In Cement Mortar 1:5 Cum 5587.00
iv. In Cement Mortar 1:6 Cum 5514.00
(b) Brick work with well burnt chimney bricks having
crushing strength not less than 25 kg/cm² and water
absorption not more than 20% in super structure above
plinth level and up to floor two level i/c form work &
curing etc. complete.
i. In Cement Mortar 1:3 Cum 6520.00

212
S.No. Items Unit Rates in
Rs.
ii. In Cement Mortar 1:4 Cum 6004.00
iii. In Cement Mortar 1:5 Cum 5878.00
iv. In Cement Mortar 1:6 Cum 5794.00
(c) Extra rate for Brick work in superstructure above floor Cum 159.00
two level for each additional floor or part thereof
respective item.

(d) Half brick masonary with well burnt chimney bricks


crushing strength not less than 25kg/cm² and water
absorption not more than 20% is superstructure above
plinth level and up to floor two level.
i. Cement mortar 1:3 Sqm 752.00
ii. Cement mortar 1:4 Sqm 690.00
(e) Brick work with open Bhatta bricks having crushing
strength not less than 20 kg/cm² and water absorption
not more than 25% in foundation & plinth i/c curing
etc. complete.

(i) In Cement Mortar 1:3 Cum 5695.00


(ii) In Cement Mortar 1:4 Cum 5491.00
(iii) In Cement Mortar 1:5 Cum 5364.00
(iv) In Cement Mortar 1:6 Cum 5287.00
(f) Brick work with open Bhatta bricks having crushing
strength not less than 20 kg/cm² and water absorption
not more than 25% in super structure above plinth level
and up to floor two level i/c form work & curing etc.
complete.

(i) In Cement Mortar 1:3 Cum 6395.00


(ii) In Cement Mortar 1:4 Cum 5713.00
(iii) In Cement Mortar 1:5 Cum 5587.00
(iv) In Cement Mortar 1:6 Cum 5509.00

PLASTER

16.29 12mm thick cement plaster in single coat including


(a) finishing even, smooth and curing complete.
i. 1:3(Cement 1: Sand 3) Sqm 156.00

213
S.No. Items Unit Rates in
Rs.
ii 1:4(Cement 1: Sand 4) Sqm 146.00
iii 1:5(Cement 1: Sand 5) Sqm 139.00
iv 1:6(Cement 1: Sand 6) Sqm 135.00
(b) 15mm thick cement plaster in single coat i/c finished
even, smooth and curing complete
i. in CM 1:3 Sqm 169.00
ii in CM 1:4 Sqm 157.00
iii in CM 1:5 Sqm 148.00
iv in CM 1:6 Sqm 143.00
v. Neat cement punning Sqm 27.00
(c) 18mm thick cement plaster in 2 coats under layer Sqm 196.00
12mm CP 1:5 (1 cement:5 coarse sand) and top
layer 6mm thick cement plaster 1:3 (1 cement:3 fine
sand) finished even, smooth and curing complete.
(d) 20 mm thick cement plaster in single coat i/c finishing
even, smooth and curing complete
i. in CM 1:3 Sqm 211.00
ii in CM 1:4 Sqm 194.00
iii in CM 1:5 Sqm 183.00
iv in CM 1:6 Sqm 177.00

FORM WORK

16.30 Providing & fixing form work i/c centering and


shuttering including strutting, propping etc. and
removal of form work for:
i Foundation , footing, bases of columns ,etc for mass sqm 182.00
concrete
ii Wall ( any thickness ) including attached pilasters, sqm 317.00
buttresses, plinth and string courses etc.
iii Suspended floors, roofs, landings, balconies and access sqm 354.00
platform.
iv Lintels, beams , plinth beams, girders, bressumers and sqm 298.00
cantilevers.
v Columns, pillars, piers, Abutments, posts and Struts sqm 406.00
vi Stairs, ( excluding landings ) except spiral- staircases sqm 429.00
16.31 Close timbering in trenches including strutting,
shoring and packing cavities(wherever required)
complete (Measurement to be taken of the face area
timbered)

214
S.No. Items Unit Rates in
Rs.
i Depth not exceeding 1.5 mtr. Sqm 168.00
ii Depth exceeding 1.5 mtr. but not exceeding 3.0 mtr. Sqm 173.00
iii Depth exceeding 3.0 mtr. but not exceeding 4.5 mtr. Sqm 178.00
iv Depth exceeding 4.5 mtr. but not exceeding 6.0 mtr. Sqm 183.00
v Depth exceeding 6.0 mtr. but not exceeding 7.5 mtr. Sqm 188.00
vi Depth exceeding 7.5 mtr. but not exceeding 9.0 mtr. Sqm 193.00
16.32 Close Timbering in case of shafts, wells, cesspits
manholes and the like including strutting, shoring and
packing cavities ( wherever required ) etc. complete
( Measurements to be taken of the face area timbered )

i Depth not exceeding 1.5 mtr. Sqm 171.00


ii Depth exceeding 1.5 mtr. but not exceeding 3.0 mtr. Sqm 181.00
iii Depth exceeding 3.0 mtr. but not exceeding 4.5 mtr. Sqm 192.00
iv Depth exceeding 4.5 mtr. but not exceeding 6.0 mtr. Sqm 202.00
v Depth exceeding 6.0 mtr. but not exceeding 7.5 mtr. Sqm 212.00
vi Depth exceeding 7.5 mtr. but not exceeding 9.0 mtr. Sqm 222.00
STONE WORK
16.33 Coursed rubble masonry ( first sort ) with hard stone in cum 4341.00
foundation and plinth
cement mortar 1:6

16.34 Coursed rubble masonry ( Second sort ) with hard stone cum 4047.00
in foundation and plinth
Cement mortar 1:6
16.35 Coursed rubble masonry with hard stone ( first or
Second sort ) in Superstructure above plinth level
and up to floor two level.

i Masonry work ( first sort) in Cement mortar 1:6 cum 4971.00


ii Masonry work ( Second sort) in Cement mortar 1:6 cum 4677.00

16.36 Extra Coursed rubble masonry with hard stone ( first or cum 110.00
Second sort ) in Superstructure above floor II level
for every floors or part thereof.

215
S.No. Items Unit Rates in
Rs.
16.37 Extra Coursed rubble masonry with hard stone
(first or Second sort ) in
i Square or rectangular pillars cum 366.00

ii Circular pillars cum 1228.00

16.38 Pointing on stone work with cement mortar 1:3


( 1 cement : 3 fine sand )

i Flush / ruled pointing sqm 127.00


ii Raised and cut pointing sqm 232.00

FINISHING WORK

16.39 White washing with lime to give an even shade :


i New work ( three or more coats ) sqm 15.00
16.40 White washing with lime to give an even shade :
i Old work ( two or more coats ) sqm 9.00

ii Old work ( One or more coats ) sqm 5.00


16.41 Finishing walls with water proofing cement paint of
required shade :
i New work ( two or more coats applied @ 3.84 kg/10 sqm 53.00
sqm)
16.42 Finishing walls with Acrylic Smooth exterior paint of
required shade :
i New work ( two or more coats applied @ 1.67 ltr/10 sqm 91.00
sqm over and including priming coat of exterior primer
applied @ 2.20 kg/ 10sqm)

16.43 Painting with synthetic enamel paint of approved brand


and manufacture to give an even shade :
i ( two or more coats ) on New work sqm 68.00
16.44 Painting with synthetic enamel paint of approved brand
and manufacture to give an even shade :

i ( One or more coats ) on Old work sqm 45.00

216
S.No. Items Unit Rates in
Rs.
CONSTRUCTION OF BRICK MASONARY
VALVE CHAMBER

16.45 Construction of Brick masonary valve chamber with No. 6219.00


20 cm thick wall in 1:6 C.M. with 12mm thick 1:4
Cement Plaster and base course 10 cm. thick in M-15.
Inside Dimensions 110x80x100cm M-20 RCC chamber
cover size 130x100cmx120cm including cost of
materials, labour etc. complete.

217
CHAPTER XVII

GENERAL MISCELLANEOUS

218
CHAPTER XVII
GENERAL MISCELLANEOUS
NOTES:

1. The rates include all tools and plants, chain, pulley blocks, other appliances etc.
required for execution of the works.

2 The works to be executed in accordance with the I.S.Specifications, General


specifications in vogue in P.H.E. Department and the special notes if any
covered under the N.I.T. of the work.

3 Rates for items of cutting and making good roads etc. include lead for the
materials and reconstruction by appropriate compaction equipment and methods
as per relevant IS Codes.

4 Where cracked pipe or cut piece is required to be used on line to take a tyton
ring joint, it is necessary to cut the cracked portion and chamfer for the pipe. In
a cut piece, only chamfering would be required. These rates have been
introduced separately for cutting and chamfering. The rates include requirement
of tools and plants, lead and lift etc.

5 During the course of execution, it sometimes becomes necessary to provide a


non-standard special to fit into the pipeline. This can be made out of steel
plates.

6. All materials shall conform to relevant ISS.

7. Pavement and road surface may be removed as a part of the trench excavation
and the amount removed shall depend upon the width of trench specified for the
installation of the pipe and the width and length of the pavement area required
to be removed for laying pipes. The width of pavement removal along the
normal trench for the installation of the pipe shall not exceed the width of the
trench specified by more then 15 CM on each side of the trench. Wherever in
the opinion of the Engineer in charge existing conditions make it necessary or
advisable to remove additional pavement, it shall be removed as directed by the
Engineer in charge.

8. Where any pavement, shrubbery, fence, poles or other property and surface
structures have been damaged, removed or disturbed during the course of the
work, such property and surface structures shall be replaced or repaired after
completion of work.

9. All pavements, paved foot paths, curbing, gutters, shrubbery, fences, poles, rod
or other property and surface structures removed or disturbed as a part of the
work shall be restored to a condition equal to that before the work began,
furnishing all labour and material incidental thereto. In restoring the pavement
sound materials may be reused. No Permanent pavement shall be restored unless

219
and until, in the opinion of the Engineer in charge the condition of the backfill
is such as to properly support the pavement.

10. All construction material, and all tools and temporary structures shall be
removed form the site as directed by the Engineer in charge. All dirt, rubbish
and excess earth form the excavation shall be taken off to a specified dumping
site as directed by Engineer in Charge and the construction site shall be kept
clean to the satisfaction of the Engineer-in-charge.

11. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

220
GENERAL MISCELLANEOUS

S. No. Items Unit Rates in Rs.


17.1 Labour for cutting following cast iron
pipes of any type and class.
80 mm dia. Per Cut 48.00
100 mm dia. Per Cut 65.00
150 mm dia. Per Cut 121.00
200 mm dia. Per Cut 162.00
250 mm dia. Per Cut 201.00
300 mm dia. Per Cut 241.00
350 mm dia. Per Cut 280.00
400 mm dia. Per Cut 320.00
450 mm dia. Per Cut 359.00
500 mm dia. Per Cut 400.00
600 mm dia. Per Cut 475.00
700 mm dia. Per Cut 514.00
750 mm dia. Per Cut 553.00
800 mm dia. Per Cut 593.00
900 mm dia. Per Cut 633.00
17.2 Labour for cutting following Asbestos
Cement Pressure Pipes of any type and
class.
80 mm dia. Per Cut 24.00
100 mm dia. Per Cut 33.00
150 mm dia. Per Cut 61.00
200 mm dia. Per Cut 81.00
250 mm dia. Per Cut 100.00
300 mm dia. Per Cut 111.00
350 mm dia. Per Cut 128.00
17.3 Labour for cutting following P. V. C.
Pipes of any type and class.
80 mm dia. Per Cut 12.00
100 mm dia. Per Cut 16.00
150 mm dia. Per Cut 30.00
200 mm dia. Per Cut 41.00
17.4 Labour only for cutting following
Ductile Iron pipes of any type and class.
80 mm dia. Per Cut 42.00
100 mm dia. Per Cut 57.00
150 mm dia. Per Cut 106.00
200 mm dia. Per Cut 142.00
250 mm dia. Per Cut 177.00
300 mm dia. Per Cut 212.00

221
S. No. Items Unit Rates in Rs.
350 mm dia. Per Cut 246.00
400 mm dia. Per Cut 281.00
450 mm dia. Per Cut 316.00
500 mm dia. Per Cut 352.00
600 mm dia. Per Cut 418.00
700 mm dia. Per Cut 452.00
750 mm dia. Per Cut 487.00
800 mm dia. Per Cut 522.00
900 mm dia. Per Cut 557.00
17.5 Labour for cutting following
Galvanised Iron (MS) Pipes of any type
and class.
15 mm dia. Per Cut 4.00
20 mm dia. Per Cut 7.00
25 mm dia. Per Cut 10.00
32 mm dia. Per Cut 15.00
40 mm dia. Per Cut 20.00
50 mm dia. Per Cut 24.00
65 mm dia. Per Cut 29.00
80 mm dia. Per Cut 37.00
100 mm dia Per Cut 39.00
125 mm dia Per Cut 45.00
150 mm dia Per Cut 50.00
17.6 Chamfering cast iron pipes of all types
and classes to make suitable for tyton
joints.
Up To150 mm dia. Each
851.00
End
200 mm dia. Each
1059.00
End
250 mm dia. Each
1167.00
End
300 mm dia. Each
1326.00
End
400 mm dia. Each
1591.00
End
450 mm dia. Each
1730.00
End
500 mm dia. Each
1857.00
End
600 mm dia. Each
2122.00
End
700 mm dia. Each
2387.00
End

222
S. No. Items Unit Rates in Rs.
750 mm dia. Each
2652.00
End
800 mm dia. Each
2918.00
End
900 mm dia. Each
3183.00
End
1000 mm dia. Each
3148.00
End
17.7 Dismantling following old cast iron
socket and spigot pipes class 'L.A.' 'A'
& 'B' including breaking lead caulked
joints, melting of lead and making it in
to blocks including stacking of pipes at
site lead upto 60 mtrs. Class Class Class
LA A B
80 mm dia. R.Mtr. 9.00 10.00 11.00
100 mm dia. R.Mtr. 11.00 12.00 13.00
125 mm dia. R.Mtr. 15.00 16.00 17.00
150 mm dia. R.Mtr. 18.00 20.00 22.00
200 mm dia. R.Mtr. 27.00 29.00 31.00
250 mm dia. R.Mtr. 36.00 39.00 42.00
300 mm dia. R.Mtr. 47.00 51.00 54.00
350 mm dia. R.Mtr. 59.00 64.00 68.00
400 mm dia. R.Mtr. 72.00 79.00 84.00
450 mm dia. R.Mtr. 87.00 96.00 101.00
500 mm dia. R.Mtr. 102.00 111.00 118.00
600 mm dia. R.Mtr. 136.00 149.00 157.00
700 mm dia. R.Mtr. 175.00 191.00 203.00
750 mm dia. R.Mtr. 195.00 213.00 228.00
800 mm dia R.Mtr. 275.00 302.00 329.00
900 mm dia R.Mtr. 335.00 369.00 403.00
1000 mm dia. R.Mtr. 403.00 444.00 483.00
17.8 Unloading from railway wagon, pipes
and machinery
(a) Pipes upto 500 mm dia and machinery Tonne 450.00
below 1.00 tonne
(b) Pipes 500 mm dia and above heavy Tonne 2040.00
Machinery weighing more than one
tonne require use of crane etc.
17.9 Stacking of pipe and machinery at Tonne 580.00
station Yard.
17.10 Carriage of Material by Mechanical
transport including loading unloading &
stacking etc.

223
S. No. Items Unit Rates in Rs.
17.10.1 Lime, Alum., Bleaching Powder Distance Per Rates in Rs.
1. Distance 1 Km. Cum 90.00
2. Distance 2 km Cum 103.00
3. Distance 3 km Cum 116.00
4. Distance 4 km Cum 128.00
5. Distance 5 km Cum 140.00
6. Beyond 5km upto 10km. add per km Cum 10.00
7. Beyond 10km. upto 20km. add per Cum 8.00
km.
8. Beyond 20km. add per km. Cum 7.00
17.10.2 Earth & Moorum Cum
1. Distance 1 km Cum 113.00
2. Distance 2 km Cum 129.00
3. Distance 3 km Cum 145.00
4. Distance 4 km Cum 160.00
5. Distance 5 km Cum 175.00
6. Beyond 5km upto 10km. add per km Cum 12.00
7. Beyond 10km. upto 20km. add per Cum 10.00
km.
8. Beyond 20km. add per km. Cum 8.00
17.10.3 G.I.,C.I.,ACP Pipes below 100mm dia Cum
(a) and other heavy material and
machinery
1. Distance 1 km Per Tonne 80.00
2. Distance 2 km Per Tonne 92.00
3. Distance 3 km Per Tonne 103.00
4. Distance 4 km Per Tonne 114.00
5. Distance 5 km Per Tonne 124.00
6. Beyond 5km upto 10km. add per km Per Tonne 9.00
7. Beyond 10km. upto 20km. add per Per Tonne 7.00
km.
8. Beyond 20km. add per additional Per Tonne 6.00
PVC pipes- 90,110,140,160,180,200
17.10.3 mm dia pipes
(b)
1. Distance 1 km Per Tonne 204.00
2. Distance 2 km Per Tonne 231.00
3. Distance 3 km Per Tonne 260.00
4. Distance 4 km Per Tonne 285.00
5. Distance 5 km Per Tonne 312.00
6. Beyond 5 Km upto 10 km. add Per Tonne 23.00
per km
7. Beyond 10 km. upto 20 km. Per Tonne 19.00
add per km.
8. Beyod 20 km. add per additional Per Tonne 16.00

224
S. No. Items Unit Rates in Rs.
17.10.4 Steel ( All types)
1. Distance 1 km Per Tonne 80.00
2. Distance 2 km Per Tonne 92.00
3. Distance 3 km Per Tonne 103.00
4. Distance 4 km Per Tonne 114.00
5. Distance 5 km Per Tonne 124.00
6. Beyond 5km upto 10km. add per km Per Tonne 9.00
7. Beyond 10km. upto 20km. add per Per Tonne 7.00
km.
8. Beyond 20km. add per additional km. Per Tonne 6.00
17.10.5 R.C.C., Pipes, Steel Pipes, ACP pipes,
CI & DI Pipes
17.10.5.1 100,150,200,250,&300 mm dia
1. Distance 1 Km. Per Tonne 184.00
2. Distance 2 km Per Tonne 209.00
3. Distance 3 km Per Tonne 233.00
4. Distance 4 km Per Tonne 256.00
5. Distance 5 km Per Tonne 279.00
6. Beyond 5km upto 10km. Add per Per Tonne 20.00
km
7. Beyond 10km. upto 20km. add Per Tonne 17.00
per km.
8. Beyond 20km. add per additional Per Tonne 13.00
km.
17.10.5.2 350,100,450,& 500 mm dia

1. Distance 1 Km. Per Tonne 1228.00


2. Distance 2 km Per Tonne 1391.00
3. Distance 3 km Per Tonne 1553.00
4. Distance 4 km Per Tonne 1708.00
5. Distance 5 km Per Tonne 1859.00
6. Beyond 5km upto 10km. add per km Per Tonne 135.00
7. Beyond 10km. upto 20km. add per km. Per Tonne 110.00
8.Beyond 20km. add per additional km Per Tonne 90.00
17.10.5.3 600,700,750,800&900mm dia

1. Distance 1 Km. Per Tonne 3070.00


2. Distance 2 km Per Tonne 3478.00
3. Distance 3 km Per Tonne 3882.00
4. Distance 4 km Per Tonne 4269.00
5. Distance 5 km Per Tonne 4647.00
6. Beyond 5km upto 10km. add per km Per Tonne 336.00
7. Beyond 10km. upto 20km. add per km. Per Tonne 276.00
8.Beyond 20km. add per additional km. Per Tonne 224.00

225
S. No. Items Unit Rates in Rs.
17.10.5.4 1000,1100, and 1200 mm dia

1. Distance 1 Km. Per Tonne 6139.00


2. Distance 2 km Per Tonne 6688.00
3. Distance 3 km Per Tonne 7763.00
4. Distance 4 km Per Tonne 8539.00
5. Distance 5 km Per Tonne 9293.00
6. Beyond 5km upto 10km. add per km Per Tonne 673.00
7. Beyond 10km. upto 20km. add per Per Tonne 551.00
km.
8. Beyond 20km. add per additional km. Per Tonne 448.00

17.11 Providing and installation of automatic


water level indicator for supervisory
control cum auto on/off of motor pump
assembly inclusive of control panel ,500 1 Job 18000.00
mtr long 2 core ,4 pair cable for small
rural water supply scheme, having
source within 500mtr as per approved
specification and as directed by
Engineer in charge.(In case of lesser
length of cable,equivalent amount @ Rs
12 /-per meter of short length will be
deducted from above rate)
17.12 Providing and installation of automatic
water level indicator for supervisory
control cum auto on/off panel of motor
pump assembly, using GSM module
based water level controller and 1 Job 25000.00
accessories for small water supply
scheme, having source more than
500mtr but within 10 Kms as per
approved specification and as directed
by Engineer in charge.
17.13 Providing and supply of Electro Fusion
Tapping Ferrule (Branch Tapping saddle)
Female BSP Threaded woth SS 304 insert
fittings in accordance with BS EN 12201:
Part-3 suitable for drinking water with in
No. 1980.00
black/ blue color manufactured from
compounded PE 80/ PE-100 virgin
polymer and compatible with PE80/PE 100
pipes, in pressure rating SDR 11 with min
PN 12.5 rated for water application with

226
S. No. Items Unit Rates in Rs.
elecctro fusion tapping ferrule saddle,
90x15mm and providing and supplying
blue 20mm dia PN-16 MDPE pipes 5-10
mtr confirming to IS 4427:1996
Manufactured from virgin resin PE 80 food
grade compounded Raw Material having
Blue color only with quality assurance
certificate from quality agencies like WRC/
CIPET (India) / DVGM/ KIWA/ SPGN
etc. for usage in drinking water system the
cost shall include testing of all materials all
taxes central, state municipal inspection
charges transportation up to site, transit
insurance, loading, unloading, stacking etc.
complete i/c cost of 15mm dia UPVC pipe
sockety Elbow, Union 20x15 mm dia PVC
reducer and providing and stainless steel
water tap with grouting of vertical pipe as
per requirement as per approved
specification and as directed by Engineer in
charge.
17.14 House hold connection with 15mm S.S. tap
including earth work in excavaton for pipe
trench in all kinds of soil & W.B.M. in
areas with demolishing cement concrete
road and reconstruction of same good with
providing and fixing 15mm G.M./ brass
ferrule 90x15mm MS/ PVC Clamp in main
line 15mm dia PVC pipe heavy class from 1 JOb 1620.00
main pipe line to house of consumer up to
5 to 10 meter long as per site condition
PVC specials such as 15mm PVC sockets
elbows, union with all other work
pertaining to it job completed, as per
approved specification and as directed by
Engineer incharge
17.15 House hold connection with 15mm S.S. tap
including earth work in excavaton for pipe
trench in all kinds of soil & W.B.M. in
areas with demolishing cement concrete
road and reconstruction of same good with
providing and fixing 15mm G.M./ brass
ferrule 90x15mm MS/ PVC Clamp in main
Job 1800.00
line, 15mm dia G.I. pipe from main pipe
line to house of consumer up to 5 to 10
meter long as per site condition i/c specials
such as G.I. Bends, elbows, tees,union etc.
with all other work pertaining to job
completed, as per approved specification
and as directed by Engineer incharge

227
S. No. Items Unit Rates in Rs.
RECTANGULAR CONCRETE
BLOCK PAVEMENT
17.16 Manufacturing, laying of cement
concrete blocks of cement Concrete
(C.C.) M30 grade and spreading 25mm
thick sand under neath and filling joints
with sand on existing base including
testing.
Concrete M30 grade for block, Sqm 1271.00
(0.600x0.450x0.200)
(Concrete M30 for edge block,
(i) (0.300x0.300x0.300))
Concrete M30 grade for block, Sqm 1076.00
(0.450x0.300x0.150)
(ii) (Concrete M30 edge for block,
(0.300x0.300x0.300))

INTERLOCKING CONCRETE
BLOCK PAVEMENT
17.17 Providing and Laying of Interlocking
Concrete Block Pavements having
(i) thickness 80 mm over bedding sand Sqm 498.00
conforming to table 1500.6 shall be
uniformly laid to a compacted thickness
of 30mm complete including testing.

(ii) Providing and Laying of Interlocking Sqm 431.00


Concrete Block Pavements having
thickness 60 mm overbedding sand
conforming to table 1500.6 shall be
uniformly laid to a compacted thickness
of 25mm complete.
17.18 Supply & erection of readymade mini Each 13500.00
pump house (control panel box) GI
sheet of 18 gauge of size 90cmx90cm
x60cm with 40x40x5mm angle Iron
frame to fix it 200mm below ground
level with hold fasts grouted in
foundation and 300mm above ground
level for clearance suitable for fixing of
control panel, fuse unit, main switch
etc. as per approved specification.
17.19 Provision for Jointing of TW to Rising Job 2700.00
Main with cost of Material/ specials
such as GI Union / CI Flange, GI
Reducer UPVC MTA FTA etc. as per
228
S. No. Items Unit Rates in Rs.
requiement of site i/c cost of labour etc.
complete as per approved specification
and as directed by Engineer in charge.
17.20 Provision for jointing of Rising main to Job 4500.00
supmp well/OHT and OHT to
Distribution pipe line with cost of
material/specials such as Bends, MTA
as per rerquirement of site i/c cost of
labour with excavation, labour as per
requirement complete as per approved
specification and as directed by
Engineer in charge.
17.21 Providing and Installation of automatic Job 7200
water level controller (Auto switch off)
with accessories i/c labour and material
etc. complete, as per approved
specification and directed by Engineer
in charge.
17.22 Provision for inter connection of old to
new pipe line with excavation of trench
as per requirement/ repairing of
leakage of pipe line of any diameter &
type of pipe line in muddy area i/c
searching of leakage point, dewetering
the trench, repairing the leakage laying
& jointing of pipe and specials, back
filling the trench i/c testing of joints
cost of labour & specials such as D-
joints couplers, solvent cement etc.
complete Job work as per approved
specification and as directed by
Engineer in charge.
50mm dia Job 1350.00
90mm dia Job 1800.00
110mm dia Job 2250.00
17.23 Provision for inter connection of old to
new pipe line with excavation of trench
as per requirement of any diameter &
type of pipe line in muddy area i/c
dewetering the trench laying & jointing
of pipe and specials, back filling the
trench i/c testing of joints cost of labour
& specials such as D-Joints couplers,
solvent cement etc, complete job work
as per approved specification and as
directed by Engineer in charge.

229
S. No. Items Unit Rates in Rs.
50/90mm dia Job 1575.00
90/110 mm dia Job 2025.00
110/110mm dia Job 2250.00
90/90 mm dia Job 1800.00
17.24 Supply of Woltman Turbine Bulk meter Job 13500.00
class b, multijet, magnetically coupled
as per specifications conforming to IS
770/1994, ISO 4064/1 and EEC
approved, including transportation to
site, storage, safety, installation, testing
commissioning, making connection
with existing pipeline having total
measuring capacity of 10,000 Kilolitre
with least cound of one Kilolitre
including excavation at site, dewetering
and reinstating the same after
completion and as per specifications
including all taxes.
17.25 Provision for Rewindidng of Job 4500.00
submerssible Motor of any diameter i/c
cost of material, labour, transportation
etc. complete in case of breakdown
maintenance as per approved
specification and as directed by
Engineer in charge.
17.26 Provision for Repairing of Job 2250.00
submerssible pump of any diameter i/c
cost of material, labour, transportation
etc. in case of breakdown maintenance
as per approved specification and as
directed by Engineer in charge
17.27 Provision for Repairing of Starter/ Job 1080.00
control panel i/c cost of material,
labour, transportation etc. complete as
per approved specification and as
directed by Engineer in charge
17.28 Provision for Repairing of old existing Job 1250.00
CI Sluice Valve i/c repairing of spindle,
check nut, changing of gland, lathe
work as per requirement, changing of
nut bolt, rubber sheet etc. complete as
per approved specification and as
directed by Engineer in charge.
BOUNDARY PILLAR
17.29 Reinforced cement concrete M15 grade Each 470.00
boundary pillars/local stone of standard

230
S. No. Items Unit Rates in Rs.
design, fixed in position including
finishing and lettering but excluding
painting .
G.I.BARBED WIRE FENCING 1.2 M.
HIGH
17.30 Providing and fixing 1.2 m high GI R.M. 357.00
barbed wire fencing with 1.8 m RCC
posts 150 mm x 150 mm placed every 3
m centre-to-centre founded in M15
grade cement concrete, 0.6 m below
ground level, every 15th post, last but
one end post and corner post shall be
strutted on both sides and end post on
one side only and provided with 9
horizontal lines and 2 diagonals
interwoven with horizontal wires, fixed
with GI staples, turn buckles etc.
complete .
G.I.BARBED WIRE FENCING 1.8 M.
HIGH
17.31 Providing and fixing 1.8 m high GI R.M. 503.00
barbed wire fencing with 2.4 m RCC
M15 grade 150 mm x 150 mm concrete
post placed every 3 m centre-to-centre
founded in M15 grade cement concrete,
0.6 m below ground level, every 15th
post, last but one end post and corner
post shall be strutted on both sides and
end post on one side only and provided
with 12 horizontal lines and 2 diagonals
interwoven with horizontal wires, fixed
with GI staples, turn buckles etc.
complete..
SIGN BOARD
17.32 Providing and fixing of typical Job 12467.00
informatory sign board. Three MS
Plates of 1.6 mm thick, top and middle
plate duly welded with MS flat iron
25mm x 5m size on back on edges. The
lower plate will be welded with MS
angle iron frame of 25mm x 25mm x
5mm. The angle iron frame of the lower
most plate and flat iron frame of middle
plate will be welded to 2 nos. 75mm x
75 mm of 12 SWG sheet tubes posts
duly embedded in cement concrete M-

231
S. No. Items Unit Rates in Rs.
15 grade blocks of 450mm x 450mm x
600mm, 600mm below ground level.
The top most diamond plate will be
welded to middle plate by 47mm x
47mm of 12 SWG steel plate tube. All
M.S. will be stove enameled on both
sides. Lettering and printing arrows,
border etc. will be painted with ready
mixed synthetic enamel paint of
superior quality in required shade and
colour. All sections of framed posts
and steel tube will be painted with
primer and two coats of epoxy paint
complete.
17.33 Construction of cement concrete Job 9152.00
information board in CC 1:2.5:5 (M15)
with skin reinforcement of 8 mm dia
HYSD bars @ 300 mm C/C both ways
size including excavation, base concrete
(M-15), priming, painting two coats
synthetic enamel paint on new concrete
surface including painting-figring Logo
and Slogen including writing of all
information about the project etc.
complete. As directed by the Engineer
incharge.
17.34 Providing and fixing of typical Job 17036.00
information board made of 75mm
square or 75mm dia. circular steel tube
of 12 SWG 3.2 m hight and cross
member 2 Nos. 1m long, fixed with
Angle iron 50 x 50 x 5 mm MS angle
on the back side 2Nos vertical and 4
Nos horizontal. It is mounted by 2
plates of 1.6mm thick and size 900 x
750 mm, the pipe shall be erracted on
600 x 600 x 750 mm foundation blocks
at appropriate depth made of cement
concrete 1:2:4, painted by standard
color with lettering, border, heading and
logo etc. using sinthetic enamel paint of
superior quality including welding,
excavation, concreting, painting of
base, border and lettering, painting and
other required details etc complete as
directed by Engineer-in-charge.

232
PART (B)

CONSTRUCTION OF TUBEWELL
AND ALLIED WORKS

233
:: GENERAL NOTES ::
CONSTRUCTION OF TUBEWELL AND ALLIED WORKS

1. The rates for various items of drilling works given in this unified schedule of
rates are based on average rates for whole of the Madhya Pradesh State. The
market rates may vary from place to place in the state depending upon the
local conditions. No contract shall, therefore be awarded directly at the rates
given in this unified schedule of rates without inviting tenders as per rules.

2. Tube wells drilled shall be perfectly vertical. The rates for drilling are
inclusive of the verticality test required to be conducted. All the relevant
Indian standards specifications of the B.I.S. shall also be applicable.

3. The rates for drilling provided in the Unified Schedule of Rates are inclusive
of depreciation charges of all the machinery, tools & plants required for
drilling operation, transportation of drilling machine, erection of machine at
site, removal of machine from site after completion, cost of water, cost of
drilling mud, fuel, labour and all other unforeseen items for drilling work and
clearance of site after completion of work.

4. For locating the proper site for tube well construction within the selected
habitation, if resistivity survey is required then the resistivity survey shall be
carried out by a well qualified and experienced geohydrologist using his own
suitable resistivity meter.

5. In the ordinary tube wells the casing pipe of specified diameter shall be
lowered up to a minimum depth of 9 meters below ground level. If the
collapsible strata in overburden continues beyond 9 meters depth then the
casing pipe shall be lowered up to rock level and embedded in rock in a depth
of 0.15 meter. The casing pipe shall also be extended above ground level in a
height of about 0.3 meter.

6. The diameter of ordinary tube wells constructed for installation of hand


pumps shall be 125 mm up to bottom level of the casing pipe and 115 mm in
the rock below the casing. Such tube wells shall be designated as 125/115
mm dia ordinary tube wells.

7. The ordinary tube wells constructed for installation of hand pumps in the
basaltic rock area where intertrappean formation (collapsible strata between
the rocks) is present. The nominal diameter of the tube well up to the level
of intertrappean formation shall be 150 mm. The intertrappean formation
shall be cased by 125 mm dia G.I. casing pipe. Therefore, the finished
nominal diameter of tube well in the intertrappean formation shall be 125 mm
but in the rock below the intertrappean formation, the nominal diameter of
tube well shall be 115 mm. Such tube wells shall be designated as
150/125/115 mm dia ordinary tube wells.

234
8. The nominal diameter of ordinary tube wells constructed for installation of
power pumps shall be 150 mm or 200 mm for the entire depth depending
upon the type and size of pump to be installed in the tube well. Such tube
wells shall be designated as 150 mm dia ordinary tube well & 200 mm dia
ordinary tube wells.

9. The gravel packed tube wells shall be constructed in alluvial formations,


suitable for such tube wells, in which the fine and uniform sand is present in
the water bearing aquifer. Such tube wells shall be constructed by direct
circulation rotary drilling method or reverse circulation rotary drilling method
using suitable rotary drilling machine.

10. The diameters of boreholes for construction of 100 mm, 150 mm & 200 mm
finished nominal diameter gravel packed tube wells shall be 300 mm, 350
mm and 400 mm respectively exclusive of pipe wall thickness. The thickness
of the gravel shroud around the screen shall generally be not less than 10 cm.
Such tube wells shall be designated as 300(100) mm dia, 350(150) mm dia,
400(200) mm dia gravel packed tube wells.

11. The gravel packed tube wells shall be constructed only after obtaining the
technical clearance of drawing & design of gravel packed tube well from the
concerned Chief Engineer.

12. The rates are inclusive of the preparation and submission of strata chart of the
tube well constructed in the prescribed proforma.

13. It shall be the responsibility of the contractor to collect the water sample from
completed tube well and send it to departmental laboratory for chemical and
bacteriological analysis. The water sample for chemical analysis shall be
collected in 2 liters plastic bottle and samples for bacteriological analysis
shall be collected in 300 ml sterilized bottle as per the direction of Engineer
in charge. Only testing charges will be borne by the department.

14. All risks of accidents and Jamming and breaking of drilling tools etc. shall be
contractor's liability. No extra charges shall be payable to the contractor on
this account.

15. Contractor shall also make arrangements of first aid facilities for any
accident. All care and precautions shall be taken and it shall be ensured that
there shall be no accidents while drilling the borehole. Proper dress and
equipments like gumboots, helmets etc. shall be provided by the contractor to
the workmen at site.

16. During any operation carried out for construction of tube well, if any tool,
pipe etc. falls down in the tube well then the contractor shall carry out the
necessary fishing operation at his own cost. The contractor shall use his own
equipment for such operation. If the tube well becomes useless due to any

235
reason, it shall be treated as abandoned tube well and no payment shall be
made for such abandoned tube well.

The contractor shall be fully responsible to fill up the abandoned bore hole
with hard soil including compaction and watering so as to make top surface
as good as original soil immediately and before shifting the drilling machine
to prevent any accident. No payment would be made to the contractor on
account of this.

17. If a tube well is found dry or with less yield and if it is not to be used for
water supply due to any reason, the tube well shall be fitted with MS cap
securely and a concrete block of 0.45m X 0.45m X 0.45m with M15 cement
concrete would be constructed on it to prevent any accident or damage to the
tube well and also to use the bore at any later stage for recharging or for any
other purpose.

18. The Lowering and fixing of casing pipe in ordinary tube well and lowering of
casing assembly in the gravel packed tube wells shall be done in the presence
of authorised representative of the Engineer in Charge of work. The G.I.
casing pipe to be lowered and fixed in intertrappean formation shall be
jointed by welding only. In the case of gravel packed tube well it shall be
ensured by the contractor that the slotted pipes or screened pipes shall be
lowered in the tube well at the locations of water bearing aquifers as per
design. The contractor shall also ensure that joints of the pipes in casing
assembly are rigid and water tight and a bail plug is properly fixed in the
bottom of casing assembly.

19. All the gravel to be used, as pack in gravel packed tube wells shall be as
specified in IS 4097: 1988 (Reaffirmed - 1993).

20. The development of tube well shall be continued during drilling operation. At
the time of flushing by compressor the discharge from tube well during the
development process shall also be measured by ‘V’ notch for yield and shall
be recorded on regular intervals for which no separate payment shall be
made. In case of gravel packed tube wells, development by compressor for
minimum eight hours after completion of drilling of tube well shall be done
and paid as per item number 4 of chapter 5. The development of ordinary
tubewells (other than gravel packed tubewells) shall be done by the drilling
machines during the drilling operations and no separate payment for
development of such ordinary tubewells shall be made. The development of
all type of the tubewells shall be done as per IS specifications (IS11189 –
1985)

21. In case of ordinary tubewells (other than gravel packed tubewells) where
power pump is to be installed, the yield test of tube well shall be conducted
by suitable capacity single phase or three phase submersible pumping set to
be operated by generator set or by taking temporary electric connection at

236
site. It shall be the responsibility of the contractor to arrange for suitable
capacity submersible pumping set, generator set, or temporary electrical
connection, suitable measuring equipments for measuring the discharge and
draw down of the tube well. The rates for item of yield test given in this
unified schedule of rates include all such arrangements. The maximum
duration of yield test shall be eight hours.

22. The tube well shall be disinfected after completion of yield test using
bleaching powder solution as per the direction of Engineer in charge, and
paid as per provision in the USoR.

23. The installation of hand pump over the tube well shall be carried out as per IS
specifications (IS15500 PART 1 to 8– 2004). All the exterior parts of pump
coming in contact with the water shall be thoroughly cleaned and dusted with
bleaching powder. The hand pump after installation shall be tested for its
proper installation by operating it continuously at least for four hour and
measuring the rate of discharge from hand pump. The rates for the item of
installation of hand pump and yield test by hand pump given in this unified
schedule of rates shall be applicable.

24. For construction of platform and drain for the hand pump, the contractor shall
use only steel plate frame shuttering designed as per the dimensional
requirement of platform and drain. This shuttering shall be got approved from
the Engineer-in-Charge. In case of construction of platforms in areas having
black cotton soil, the top thirty centimeters of the black cotton soil shall be
excavated and replaced with morrum boulder, duly rammed and watered in
layers, prior to the construction of such platforms including drain, pedestal
and washing platform. Rates for these works have been provided for in the
USOR.

25. All contracts based on this unified schedule of rates shall be governed by the
directions and other notes and conditions given in this unified schedule of
rates, in addition to all the other conditions of the agreement. As the rates in
this unified schedule of rates are linked to these conditions and directions, it
shall not be necessary to attach the copies of these conditions to the contract
agreement.

26. In the interpretation of description of items or rates of this unified schedule


of rates and specifications, the decision of the Engineer-In- Chief shall be
final.

27. The issue rates of casing pipes, hand pumps and other material given in
Annexure-1 of this unified schedule rates are only for the purpose of
preparing realistic estimates. These rates are not given for making purchases
or for entering into any contracts.

237
28. The rates for various items of works given in this unified schedule of rates
includes for 1% overhead and 10% contractor's profit. If the work is carried
out departmentally then the rates applicable for departmental works shall be
at-least 9.90% [(100x11)/111] less than the rates of various items given in
this unified schedule of rates.

29. The following Indian standard shall be referred to:-


(1) I.S.2800 (Part-I) :1991 (Reaffirmed 2001)- Code of practice for
construction & testing of tube wells/Bore wells.
(2) I.S. 2800(Part-II):1979 (Reaffirmed 1999)- Code of practice for
construction & testing of tube wells/Bore wells.
(3) I.S. 4097-1988(Reaffirmed 1999): Specification for Gravel for use as
pack in tube wells
(4) I.S.11189-1985(Reaffirmed1999): Methods of tubewell development
(5) I.S.1239 (Part-I) 1990 Mild steel tubes, tubular & other wrought steel
fittings-specifications.
(6) I.S. 12818: 1992 Unplasticized PVC screen and casing pipes for
bore/tube well- specification.
(7) I.S. 15500 (Parts 1 to 8) Deep well hand pumps, components and
special tools- specifications.
(8) The issue rates for various items like Hand pump, Casing pipes etc.
has been arrived after adding 3% storage and handling charges and
these rates are to be considered for preparation of estimates only and
no payment of material shall be made on the basis of these issue
rates.
(9) Rate for hand pump is taken as per LUN Contract Ref. No. RC/2011
2012/0156 dt. 28 Mar 2012, MPLUN Service Commission @ 2%
Service Tax on MPLUN @ 10.30%
(10) Rate for G.I. Pipe medium class is taken as per LUN R/L No.
LUN/MKT/Coord/PS-XY 2010-11/2181/R.II dated 26.02.11 & i/c of
third party inspection charges @ 0.5% & G S T Extra
(11) Rates for UPVC casing pipe are taken as per LUN RC/LUN/MKT
/2010-11/0128-2 dated 4.03.11, & i/c of third party inspection
charges @ 0.5% & G S T Extra

30. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra
amount as per prevailing rates on the sum of the estimate to arrive at the
gross amount.

238
CHAPTER - XVIII

RESISTIVITY SURVEY

239
CHAPTER- XVIII
RESISTIVITY SURVEY

S.No. Item Unit Rate in


Rs.
18.1 Carrying out the resistivity survey by VES method Per 1606.00
using Schlumberger configuration for locating the successful
proper spot with three soundings for drilling of tube point
well within the selected Habitation, including
photography , interpretation of resistivity data and
submission of report in the desired format along with
resistivity readings, necessary graph and
photographs.
18.2 Geophysical & Hydrological Survey for lineament 1 Job 5960.00
marking in field unconfined aquifer analysis,
analyzing ground water movement, estimation of
SWI yield finalizing of recharging structure,
inclusive of preparation of requisite map and final
report as per hydro-geological specification for
recharging shaft along with all activities.

240
CHAPTER - XIX

CONSTRUCTION OF ORDINARY
TUBE WELL

241
CHAPTER- XIX
CONSTRUCTION OF ORDINARY TUBE WELL

S.No. Item Unit Rate in


Rs.
19.1 Drilling of perfectly vertical bore hole of a diameter to
receive 125 mm nominal diameter casing pipe upto desired
depth below ground level inclusive of the labour charges
for transporting, lowering and fixing of 125 mm nominal
diameter M.S./ G.I /U.P.V.C..casing pipe indise the bore
hole including all works pertaining to drilling such as
transportation , installation and removal of drilling machine
etc. complete.
(a) In all type of collapsible strata consisting of soils, clays, Meter 499.00
sand , moorum, gravel, blouders etc
(b) In all types of rocks. Meter 581.00
19.2 Drilling of perfectly vertical bore hole of 115 m.m. Meter 548.00
diameter up to desired depth below ground level in all types
of rocks including all works pertaining to drilling such as
transportation, installation and removal of drilling machine
etc. complete.
19.3 Drilling of perfectly vertical bore hole of a diameter
suitable to receive 150 mm nominal diameter casing pipe
upto desired depth below ground level inclusive of the
labour charges for transporting, lowering and fixing of 150
mm nominal diameter and fixing of 150 mm nominal
diameter M.S./ G.I. / U.P.V.C. casing pipe inside the bore
hole including all works pertaining to drilling such as
transportation, installation and removal of drilling machine
etc. complete.
(a) In all type of collapsible strata consisting of soils, clays, Meter 518.00
sand , moorum, gravel, boulders etc.
(b) In all types of rocks. Meter 628.00
19.4 Drilling of perfectly vertical bore hole of 150 m.m. Meter 599.00
diameter up to desired depth below ground level in all types
of rock including all works pertaining to drilling such as
transportation, installation and removal of drilling machine
etc. complete.
19.5 Drilling of perfectly vertical bore hole of 165 m.m. Meter 603.00
diameter up to desired depth below ground level in all types
of rock including all works pertaining to drilling such as
transportation, installation and removal of drilling machine
etc. complete.

242
S.No. Item Unit Rate in
Rs.
19.6 Drilling of perfectly vertical bore hole of a diameter
suitable to receive 200 mm nominal diameter casing pipe
upto desired depth below ground level inclusive of the
labour charges for transporting, lowering and fixing of 200
mm nominal diameter M.S./ G.I. / U.P.V.C. casing pipe
inside the bore hole including all works pertaining to
drilling such as transportation, installation and removal of
drilling machine etc. complete.
(a) In all type of collapsible strata consisting of soils, clays, Meter 536.00
sand , moorum, gravel, boulders etc.
(b) In all types of rocks. Meter 707.00
19.7 Drilling of perfectly vertical bore hole of 200 m.m.
diameter up to desired depth below ground level including
all works pertaining to drilling such as transportation,
installation and removal of drilling machine etc. complete.
(a) In all type of collapsible strata (intertrappean formation ) Meter 611.00
including charges for transportation , lowering and fixing
of 150 mm nominal diameter GI casing pipe, welded joints
only .
(b) In all types of rocks. Meter 763.00
19.8 Drilling of perfectly vertical bore hole of 150 mm diameter Meter 615.00
up to desired depth below ground level un all types of strata
including all works pertaining to drilling such as
transportation installation and removal of drilling machine
etc. complete in intertrappean formations (collapsible strata
between rocks) including charges for transportation and
making all necessary arrangements’ etc, including lowering
and fixing of 125 mm nominal diameter (G.I. or U.P.V.C.
casing pipe .
19.9 Providing and fixing of well cap on top of the tube well for
protection
M. S. Caps -
(a) 100 mm dia. each 270.00
(b) 125 mm dia. each 305.00
(c) 150 mm dia. each 370.00
(d) 200 mm dia. each 400.00
20 Construction of concrete block over dry tube wells for each 619.00
protection of size 0.45m x 0.45m x 0.45 m in M-15
cement concrete mix complete work.

243
CHAPTER-XX

CONSTRUCTION OF GRAVEL PACKED


TUBEWELL

244
CHAPTER-XX
CONSTRUCTION OF GRAVEL PACKED TUBEWELL

S.No. Item Unit Rate in Rs.


20.1 Drilling of perfectly vertical bore hole of
following diameters for construction of Gravel
Packed tube well up to desired depth in alluvial
formation consisting of Soils, Clays, Sand, Gravel,
Moorum, Boulders etc. and retaining the bore hole
by using suitable drilling mud or foam or
temporary housing pipe including all works
pertaining to drilling such as transportation,
installation and removal of drilling machine etc.
complete.
(a) 300 m.m diameter Meter 836.00
(b) 350 m.m diameter Meter 878.00
(c) 400 m.m diameter Meter 917.00
20.2 Labour charges for assembling, centering and
lowering of properly designed casing pipe
assembly inside the bore hole drilled for
construction of Gravel Packed tube well including
the cost of providing and fixing of centraliser, and
transportation of casing assembly etc. complete .
(a) Casing assembly composed of 100 m.m. diameter Meter 44.00
blank and slotted G.I. Casing pipes.
(b) Casing assembly composed of 150 m.m. diameter Meter 57.00
blank and slotted G.I. Casing pipes.
(c) Casing assembly composed of 200 m.m. diameter Meter 70.00
blank and slotted G.I. Casing pipes.
(d) Casing assembly composed of 100 m.m. dia. Meter 30.00
UPVC blank and screened pipes.
(e) Casing assembly composed of 150 m.m. dia. Meter 41.00
UPVC blank and screened pipes.
(f) Casing assembly composed of 200 m.m. dia. Meter 53.00
UPVC blank and screened pipes.
20.3 Providing and fixing of M.S. bail plug as per I.S. 2800
( PART-I) 1991 in the bottom of casing assembly

(a) 100 m.m diameter each 530.00

(b) 150 m.m diameter each 605.00


each 690.00
(c) 200 m.m diameter

245
S.No. Item Unit Rate in Rs.
20.4 Providing gravel packing with uniformly graded Cu.m 4211.00
gravel as per I.S.4097 of 1967 ( revised up to
date ) in the annular space between outer wall of
casing pipe assembly and inner wall of bore hole
including cost of gravel , transportation, stacking ,
washing and packing in layers of suitable
thickness including all lead and lifts complete .
20.5 Providing gravel with uniformly graded gravel as Cu.m 3800.00
per I.S.4097 of 1967 ( revised up to date ) for
gravel packing .
20.6 Providing and fixing of well cap on top of the tube
well for protection
M. S. Caps -
(a) 100 mm dia. each 270.00

(b) 125 mm dia. each 305.00

(c) 150 mm dia. each 370.00

(d) 200 mm dia. each 400.00


20.7 Construction of concrete block over dry tube wells each 619.00
for protection of size 0.45m x 0.45m x 0.45 m in
M-15 cement concrete mix complete work.

246
CHAPTER-XXI

INSTALLATION OF HAND PUMP AND


CONSTRUCTION OF PLATFORM
DRAIN AND SOKAGE PIT

247
CHAPTER-XXI
INSTALLATION OF HAND PUMP AND CONSTRUCTION OF
PLATFORM DRAIN AND SOKAGE PIT

S.No. Item Unit Rate in


Rs.
21.1 Labour charges for installation of India Mark II Hand Each 1031.00
Pump with 30 meter long 32 mm dia. Riser pipe
assembly and all other accessories including
transportation of Hnad Pump from specified
departmental stores to site.
21.2 Add to item No. 1 above for fixing the extra length of meter 20.00
riser pipe assembly beyond 30 meters
21.3 Construction of 76 cm x 76 cm x 40 cm foundation Each 941.00
block in 1:2:4 cement concrete for fixing the pedestal
of Hand Pump including excavation , cost of material
and labours etc. complete.
21.4 Construction of cement concrete plateform as per Each 4121.00
design around the hand pump in 1:2:4 cement
concrete including excavation, centering, shuttering,
cost of all the materials and labours and curing etc.
complete.
21.5 Construction of cement concrete plateform as per Each 4482.00
design around the hand pump in 1:2:4 cement
concrete including excavation, centering, shuttering,
cost of all the materials and labour and curing etc.
complete. Including filling in 30 cm depth after
removing Black cotton soil including ramming,
watering etc. complete in areas of Black cotton soils.

21.6 Construction of cement concrete drain as per design meter 323.00


in 1:2:4 cement concrete including excavation,
centering, shuttering, cost of all the materials and
labour and curing etc. complete.
21.7 Construction of cement concrete drain as per design meter 450.00
in 1:2:4 cement concrete including excavation,
centering, shuttering, cost of all the materials and
labour and curing etc. complete. Including filling in
30 cm depth after removing Black cotton soil
including ramming, watering etc. complete in areas of
Black cotton soils.

248
S.No. Item Unit Rate in
Rs.
21.8 Construction of 1.20 cm x 1.20 cm x 0.20 m cement Each 1289.00
concrete washing platform in cement concrete 1:2:4
including excavation, centering, shuttering, cost of all
the materials and labour and curing etc. complete.

21.9 Construction of 1.20 cm x 1.20 cm x 0.20 m cement Each 1456.00


concrete washing platform in cement concrete 1:2:4
including excavation, centering, shuttering, cost of all
the materials and labour and curing etc. complete.
Including filling in 30 cm depth after removing Black
cotton soil including ramming, watering etc. complete
in areas of Black cotton soils.
21.10 Construction of sokage pit of 70 cm dia. And 1.0 m Each 949.00
deep including excavation, brick lining at top in 1:4
cement mortar, filling broken bricks etc. and cost of
all the materials and labour and curing etc. complete.

249
CHAPTER- XXII

DEVELOPMENT, YIELD TEST


AND
DISINFECTION OF TUBE WELL

250
CHAPTER- XXII
DEVELOPMENT, YIELD TEST AND
DISINFECTION OF TUBE WELL

S.No. Item Unit Rate in


Rs.
22.1 Conducting the yield test of tubewell by operating the
pumping set continuously for a desired time period and
measuring the discharge and drawdown of tubewell at
a suitable time interval as per the direction of Engineer
in Charge including cost of energy, cost of installation
of suitable measuring device and hire charges of
pumping set etc. complete.

(a) Submersible pumping set up to 1 to 3 H.P. Per 631.00


hour
(b) Submersible pumping set above 3 to 7.5 H.P. Per 677.00
hour
(c) Submersible pumping set above 7.5 H.P. Per 766.00
hour
22.2 Development of gravel packed tube well by Air Per 942.00
Compressor of suitable capacity including hire charges hour
for all the required tools and plants etc. complete, for
maximum duration of eight hours.

22.3 Measurement of yield of tube well by operating hand Each 688.00


pump continuously for four hours manually.

22.4 Disinfection of tube well using bleaching powder Each 60.00


solution as per the direction of the Engineer in Charge
including the cost of bleaching powder and labour etc.
complete.

251
CHAPTER- XXIII

ODEX TYPE OF TUBEWELL

252
CHAPTER- XXIII
ODEX TYPE OF TUBEWELL
S.No. Item Unit Rate in
Rs.
23.1 Drilling of perfectly vertical bore hole by odex
method of a diameter to receive 125 mm nominal
diameter casing pipe up to desired depth below
ground level inclusive of the labour charges for
transporting, lowering and fixing of 125 mm nominal
diameter suitable for odex drilling M.S./G.I./
Seamless casing pipe inside the bore hole BY
welding joint including all works pertaining to
drilling such as transportation , installation and
removal of drilling machine etc. complete.
(a) In all type of collapsible strata consisting of soils, Meter 743.00
clays, sand , moorum, gravel, boulders etc.
(b) In all types of rocks. Meter 864.00
23.2 After completion of bore hole by odex method Meter 455.00
making of slots cutting on casing pipe at the aquifers
level . The size of slots is 2mm wide x 7.5mm long in
set of 4 slots around the length wise in casing pipe
(G.I./MS/Seamless) . Each meter length of casing
should have 140 slots on total cylindrical portion of
casing pipe .
23.3 Cost of casing shoe ( Guide Bush ) for odex drilling Each 5060.00
23.4 Drilling of perfectly vertical bore hole by odex
method of a diameter to receive 150 mm nominal
diameter casing pipe upto desired depth below
ground level inclusive of the labour charges for
transporting, lowering and fixing of 125 mm nominal
diameter suitable for odex drilling M.S./G.I./
Seamless casing pipe indise the bore hole BY
welding joint including all works pertaining to
drilling such as transportation , installation and
removal of drilling machine etc. complete.
(a) In all type of collapsible strata consisting of soils, Meter 804.00
clays, sand , moorum, gravel, blouders etc.
(b) In all types of rocks. Meter 975.00
23.5 After completion of bore hole by odex method Meter 525.00
making of slots cutting on casing pipe at the aquifers
level . The size of slots is 2mm wide x 7.5mm long in
set of 4 slots around the length wise in casing pipe
(G.I./MS/Seamless) . Each meter length of casing
should have 172 slots on total cylindrical portion of
casing pipe .
23.6 Cost of casing shoe ( Guide Bush ) for odex drilling Each 5850.00

253
CHAPTER- XXIV

MISCELLANEOUS ITEMS
OF
TUBEWELL

254
CHAPTER- XXIV
MISCELLANEOUS ITEMS OF TUBEWELL

S.No. Item Unit Rate in


Rs.

HYDROFRACTURING AND CLEANING OF


TUBEWELL
24.1 Hydro fracturing of perfectly vertical bore hole for 1 Job 13463.00
200/150/115 mm diameter bore hole up to 90 m depth
below ground level including yield testing before and
after Hydro fracture, transportation, installation and
removing of Hydro fracturing unit.
24.2 Cleaning of perfectly vertical bore hole for 1 Job 12641.00
200/150/115 mm diameter bore hole up to 60 mtrs
depth below ground level including transportation,
installation and removing of Drilling machine.
24.3 Add to item no. 24.2 above cleaning beyond 60 m Per 132.00
depth. meter
24.4 Survey work dry/ low yield tube well hydro fracturing Each 1483.00
of tube well for detection of fracture zones in tube well
by using the hole camera with monitor including
transportation and providing C.D. & photographs.
24.5 Labour charges for taking out assembly from the tube Each 870.00
well of India Mark II hand pump with 30 meters long
32mm dia riser pipe assembly and all other
accessories.
24.6 Add to item No. 24.5 above for fixing extra length of Per 29.00
pipe beyond 30 meters. Mtr.
24.7 Labour charges for lowering the assembly with Each 728.00
complete fittings of India Mark II Hand pump from the
tube well with 32mm dia 30 Meters long riser pipe
assembly and other accessories
24.8 Add to above item No. 24.7 for fixing extra length of Per 24.00
riser pipe assembly beyond 30 meters. Mtr

CONSTRUCTION OF RECHARGING PIT IN


SUBMERGENCE AREA
24.9 Construction of recharging pit of internal size 2.00 X 1 Job 41124.00
2.00X1.35 mtr. near Existing tube well , in
submergence area of pond / reservoir Including
excavation, base concrete, brick masonry work and
providing and filling filter media like boulders,
gravels, sand and synthetic membrance below sand as
per specifications, and drawing no.19 complete.

255
S.No. Item Unit Rate in
Rs.
CONSTRUCTION OF RECHARGING PIT AROUND
EXISTING TUBE WELL GIVING LESS YIELD
WITH STEINING AND CATCH DRAIN

24.10 Construction of recharging circular pit of 3.00 m outer 1 Job 54277.00


dia and 2.00 mtrs depth around the existing tube well
giving less yield perforation work in casing pipe and
providing and fixing of nariyal rope around perforated
area in full length, steening work and surrounding
catch drain work with M-20 RCC , making 90 mm dia
circular holes by fixing pieces of 90 mm dia PVC
pipes @ 300 mm c/c before concreting of steining
work of recharge pit just below G.L. to permit rain
water to enter in to the pit from catch drain, providing
and filling of recharge pit by filter media like
boulders, gravels sand and synthetic membrane
below sand as per specifications and drawing no. 20
complete.

CONSTRUCTION OF RECHARGING PIT AROUND


TUBE WELL GIVING LESS YIELD

24.11 Construction of recharging circular pit of 3.00 m dia 1 Job 16518.00


and 2.00m depth around the dry tube well, perforation
work in casing pipe and providing and fixing of nariyal
rope around perforated area in full length, providing
and filling of recharge pit by boulders, gravels sand as
filter media, synthetic membrance below sand and
making ground slope towards the constructed pit to
divert the rain water ( in soft/hard rock area) as per
specifications and drawing no. 21 complete.

REPAIRING OF HAND PUMP


24.12 Labour only for minor repairing work of India Mark II 1 Job 457.00
hand pump including replacement of unserviceable
parts ie chain, handle, axle either one or more parts as
the case may be along with overhauling of hand pump
set and transportation etc as per approved
specifications inclusive of the free services of
departmental technician (Material will be supplied by
the department).
24.13 Labour only for major repairing work of India Mark II 1 Job 1058.00
hand pump including replacement of unserviceable
parts such as washer, cylinder, riser pipe, link rod
either one or more parts as the case may be along with
overhauling, minor repairing work and transportation

256
S.No. Item Unit Rate in
Rs.
etc as per approved specification inclusive of free
services of departmental technician (Material will be
supplied by the department).
24.14 Labour only for minor repairing work of India Mark II 1 Job 585.00
hand pump including replacement of unserviceable
parts i.e chain, handle, axle either one or more parts as
the case may be along with overhauling of hand pump
set and transportation etc as per approved
specifications (Material will be supplied by the
department).
24.15 Labour only for major repairing work of India Mark II 1 Job 1109.00
hand pump including replacement of unserviceable
parts such as washer, cylinder, riser pipe, link rod
either one or more parts as the case may be along with
overhauling, minor repairing work and transportation
etc as per approved specification (Material will be
supplied by the department).

TAKING OUT FALLEN HAND PUMP PIPE


LINE ASSEMBLEY FROM TUBE WELL

24.16 Labour only for taking out of fallen hand pump pipe 1 Job 2472.00
line assembly from tube well using special T&P
required for the same i/c depositing all the obtained
material in departmental store complete item .-Depth
up to 150 mtr.

24.16.1 Removal of ordinarily Fallen Pipe Line of Hand Pump 1 Job 6126.00
from Tube well i/c arrangement of labour, skilled
person & arrangement of all tools and plant required
for the job i/c all safety measures and transportation of
recovered material from village to the departmental
store or transportation of material required for hand
pump installation from store to village, installation of
Handpump i/c loading, unloading etc. complete.

24.16.2 Removal of choked fallen pipe line of Hand Pump 1 Job 2226.00
from TW i/c arrangement of additonal labour skilled
person, arrangement of all special type tools and plant
required for the job, i/c all safety measures etc. all
complete. (This item will be paid in addition to item
No.24.16.1 if fallen pipe line is chocked)

REMOVING OF UNSERVICEABLE

257
S.No. Item Unit Rate in
Rs.
HANDPUMP
24.17 Removing of unserviceable hand pump along with 1 Job 2050.00
assembly from existing tube well i/c excavation,
cutting of casing pipe if necessary, dismantling CC
around pedestal, caping of tube well i/c making of
cement concrete block M-15 size 0.45x0.45x0.45 cm
and depositing all the obtained material in
departmental store .
24.18 LOWERING & TAKING OUT OF
SUBMERSIBLE PUMP SET
24.18.1 Labour only for taking out of single phase submersible 1 Job 1549.00
pumping set of capacity 1 to 3 HP from the tube well
with flexible/ rigid pipe line assembly, electrical cable,
nylone rope, testing etc. complete including
disconnecting the electrical cable from pump & starter
-Depth up to 150 mtr..

24.18.2 Labour only for lowering of single phase submersible 1 Job 1701.00
pumping set of capacity 1 to 3 HP in the tube well
with flexible/ rigid pipe line assembly, electrical cable,
nylone rope, testing etc. complete including
connecting the electrical cable from pump & starter -
Depth up to 150 mtr.

24.18.3 Labour only for taking out of three phase submersible


pumping set from the tube well with pipe line
assembly, electrical cable, testing etc. complete
including disconnecting the electrical cable from pump
& starter .
(i) 3 HP to 7.5 HP - Depth up to 150 mtr. 1 Job 2004.00
(ii) Above 7.5 HP to 12.5 HP - Depth up to 150 mtr. 1 Job 2308.00
(iii) Above 12.5 HP - Depth up to 150 mtr. 1 Job 2611.00
24.18.4 Labour only for lowering of three phase submersible
pumping set in the tube well with pipe line assembly,
electrical cable, testing etc. complete including
connecting the electrical cable from pump & starter .
(i) 3 HP to 7.5 HP - Depth up to 150 mtr. 1 Job 2156.00
(ii) Above 7.5 HP to 12.5 HP - Depth up to 150 mtr. 1 Job 2460.00
(iii) Above 12.5 HP - Depth up to 150 mtr. 1 Job 2763.00

TAKING OUT FALLEN SUBMERSIBLE


PUMPING SET FROM TUBE WELL
24.19 Labour only for taking out of fallen submersible
pumping set from the tube well with pipe line
assembly, electrical cable etc. complete using special

258
S.No. Item Unit Rate in
Rs.
T&P required for the same i/c depositing all the
obtained material in departmental store .
(i) 1 to 3 HP - Depth up to 150 mtr. 1 Job 2758.00
(ii) 3 to 7.5 HP - Depth up to 150 mtr. 1 Job 2933.00
(iii) 7.5 to 12.5 HP - Depth up to 150 mtr. 1 Job 3382.00
(iV) Above 12.5 HP - Depth up to 150 mtr. 1 Job 3630.00

24.20 REPAIRING OF SUBMERSIBLE MOTOR PUMP


SET
24.20.1 Removing the old burn winding from stator & cleaning
of slot then complete rewinding of submersible motor
by using PVC insulated ISI marked quality copper
conductor with suitable gauge including insulating
material like bamboo, strip, fire proof papers, leeve,
cotton tape, PVC tape including cable jointing of
motor.
A Single phase 100 mm dia
1 HP 1 Job 1975.00
2 HP 1 Job 2475.00
3 HP 1 Job 2660.00
B Three Phase 100mm & 150 mm Dia.
3 HP (100mm dia.) 1 Job 2938.00
4 HP (100mm dia.) 1 Job 3030.00
5 HP (100mm dia.) 1 Job 3401.00
3 HP (150mm dia.) 1 Job 3004.00
4 HP (150mm dia.) 1 Job 3097.00
5 HP (150mm dia.) 1 Job 3533.00
6 HP (150mm dia.) 1 Job 3864.00
Above 6.0 to7.5 HP (150mm dia.) 1 Job 5529.00
Above 7.5 to 10 HP (150mm dia.) 1 Job 6165.00
Above 10.0 to 12.5 HP (150mm dia.) 1 Job 7091.00
Above 12.5 to 15 HP (150mm dia.) 1 Job 7553.00
24.20.2 Providing & Fixing of non return valve body
1 HP to 5 HP /100mm 1 Job 427.00
3 HP to 15 HP / 150mm 1 Job 616.00
24.20.3 Providing & Fixing of Discharge outlet
1 HP to 5 HP /100mm 1 Job 240.00
3 HP to 15 HP / 150mm 1 Job 330-.00
24.20.4 Providing & Fixing of Adjusting Cap
1 HP to 5 HP /100mm 1 Job 66.00
3 HP to 15 HP / 150mm 1 Job 71.00
24.20.5 Providing & Fixing of L N key BMM
1 HP to 5 HP /100mm 1 Job 24.00
3 HP to 15 HP / 150mm 1 Job 29.00

259
S.No. Item Unit Rate in
Rs.
24.20.6 Providing & Fixing of Bush for D O L
1 HP to 5 HP /100mm 1 Job 151.00
3 HP to 15 HP / 150mm 1 Job 175.00
24.20.7 Providing & Fixing of Sleeve for D O L
1 HP to 5 HP /100mm 1 Job 132.00
3 HP to 15 HP / 150mm 1 Job 146.00
24.20.8 Providing & Fixing of stage case CI 1 Job
3 HP to 15 HP / 150mm 333.00
24.20.9 Providing & Fixing of Bowl bush GM
3 HP to 15 HP / 150mm 1 Job 184.00
24.20.10 Providing & Fixing of Bowl bush Rubber
3 HP to 15 HP / 150mm 1 Job 108.00
24.20.11 Providing & Fixing of Neck Ring GM
3 HP to 15 HP / 150mm 1 Job 156.00
24.20.12 Providing & Fixing of Pump sleeve SS
3 HP to 15 HP / 150mm 1 Job 118.00
1 HP to 5 HP /100mm 1 Job 382.00
3 HP to 15 HP / 150mm 1 Job 472.00

24.20.14 Providing & Fixing of moter bush Rubber


1 HP to 5 HP /100mm 1 Job 264.00
3 HP to 15 HP / 150mm 1 Job 312.00
24.20.15 Providing & Fixing of Impeller
1 HP to 5 HP /100mm PP 1 Job 62.00
3 HP to 15 HP / 150mm GM 1 Job 406.00
24.20.16 Providing & Fixing of Diffuser GM
3 HP to 15 HP / 150mm 1 Job 257.00
24.20.17 Providing & Fixing of Diffuser PP
1 HP to 5 HP /100mm 1 Job 62.00
3 HP to 15 HP / 150mm 1 Job 137.00
24.20.18 Providing & Fixing of sand guard
1 HP to 5 HP /100mm 1 Job 62.00
3 HP to 15 HP / 150mm 1 Job 137.00
24.20.19 Providing & Fixing of Distance piece
1 HP to 5 HP /100mm 1 Job 45.00
3 HP to 15 HP / 150mm 1 Job 108.00
24.20.20 Providing & Fixing of Oil seal
1 HP to 5 HP /100mm 1 Job 48.00
3 HP to 15 HP / 150mm 1 Job 52.00
24.20.21 Providing & Fixing of Oil seal Sleeve
1 HP to 5 HP /100mm 1 Job 108.00
3 HP to 15 HP / 150mm 1 Job 161.00
24.20.22 Providing & Fixing of Nylon Nut
1 HP to 5 HP /100mm 1 Job 10.00

260
S.No. Item Unit Rate in
Rs.
3 HP to 15 HP / 150mm 1 Job 11.00
24.20.23 Providing & Fixing of Stud for Suction
1 HP to 5 HP /100mm 1 Job 20.00
3 HP to 15 HP / 150mm 1 Job 26.00
24.20.24 Providing & Fixing of GM Washer
1 HP to 5 HP /100mm 1 Job 7.00
3 HP to 15 HP / 150mm 1 Job 12.00
24.20.25 Providing & Fixing of Grub Screw
1 HP to 5 HP /100mm 1 Job 11.00
3 HP to 15 HP / 150mm 1 Job 11.00
24.20.26 Providing & Fixing of Pump Shaft (SS) per Stage
3 HP to 15 HP / 150mm 1 Job 180.00
24.20.27 Providing & Fixing of Pump Shaft Key
1 HP to 5 HP /100mm 1 Job 52.00
3 HP to 15 HP / 150mm 1 Job 62.00
24.20.28 Providing & Fixing of Suction Housing
1 HP to 5 HP /100mm 1 Job 236.00
3 HP to 15 HP / 150mm 1 Job 339.00
24.20.29 Providing & Fixing of Pump Coupling & Motor
Coupling
1 HP to 5 HP /100mm 1 Job 358.00
3 HP to 15 HP / 150mm 1 Job 528.00
24.20.30 Providing & Fixing of Suction Housing Plate
3 HP to 15 HP / 150mm 1 Job 239.00
24.20.31 Providing & Fixing of Intermediate suction Case
3 HP to 15 HP / 150mm 1 Job 170.00
24.20.32 Providing & Fixing of Suction Housing Bush
3 HP to 15 HP / 150mm 1 Job 221.00
24.20.33 Providing & Fixing of Intermediate suction Bush
3 HP to 15 HP / 150mm 1 Job 221.00
24.20.34 Providing & Fixing of stud for Motor flange upper
1 HP to 5 HP /100mm 1 Job 17.00
3 HP to 15 HP / 150mm 1 Job 21.00
24.20.35 Providing & Fixing of stud for Motor flange lower
1 HP to 5 HP /100mm 1 Job 26.00
3 HP to 15 HP / 150mm 1 Job 33.00
24.20.36 Providing & Fixing of Bearing Housing upper
1 HP to 5 HP /100mm 1 Job 330.00
3 HP to 15 HP / 150mm 1 Job 509.00
24.20.37 Providing & Fixing of Bearing Housing lower
1 HP to 5 HP /100mm 1 Job 330.00
3 HP to 15 HP / 150mm 1 Job 509.00
24.20.38 Providing & Fixing of upper flange & lower flange
1 HP to 5 HP /100mm 1 Job 180.00

261
S.No. Item Unit Rate in
Rs.
3 HP to 15 HP / 150mm 1 Job 221.00
24.20.39 Providing & Fixing of Motor base
1 HP to 5 HP /100mm 1 Job 406.00
3 HP to 15 HP / 150mm 1 Job 528.00
24.20.40 Providing & Fixing of Thrust bearing plate complete
1 HP to 5 HP /100mm 1 Job 692.00
3 HP to 15 HP / 150mm 1 Job 786.00
24.20.41 Providing & Fixing of Thrust bearing (Carben)
1 HP to 5 HP /100mm 1 Job 472.00
3 HP to 15 HP / 150mm 1 Job 585.00
24.20.42 Providing & Fixing of Revolving disk
1 HP to 5 HP /100mm 1 Job 339.00
3 HP to 15 HP / 150mm 1 Job 519.00
24.20.43 Providing & Fixing of Thrust bearing housing CI
1 HP to 5 HP /100mm 1 Job 132.00
3 HP to 15 HP / 150mm 1 Job 203.00
24.20.44 Providing & Fixing of Rotor Sleeve
1 HP to 5 HP /100mm 1 Job 170.00
3 HP to 15 HP / 150mm 1 Job 207.00
24.20.45 Providing & Fixing of Rubber Parts 1 Job
1 HP to 5 HP /100mm 1 Job 57.00
3 HP to 15 HP / 150mm 75.00
24.20.46 Providing & Fixing of Intermediate coupling
1 HP to 5 HP /100mm 1 Job 283.00
3 HP to 15 HP / 150mm 1 Job 312.00
24.20.47 Providing & Fixing of Flange locking
1 HP to 5 HP /100mm 1 Job 48.00
3 HP to 15 HP / 150mm 1 Job 52.00
24.20.48 Providing & Fixing of Disk Locking
1 HP to 5 HP /100mm 1 Job 19.00
3 HP to 15 HP / 150mm 1 Job 21.00
24.20.49 Providing & Fixing of Chuck Nut
1 HP to 5 HP /100mm 1 Job 36.00
3 HP to 15 HP / 150mm 1 Job 48.00
24.20.50 Providing & Fixing of 8 mm Nut SS
3 HP to 15 HP / 150mm 1 Job 11.00
24.20.51 Providing & Fixing of 10 mm Nut SS
1 HP to 15 HP / 150mm 1 Job 15.00
24.20.52 Providing & Fixing of 12 mm Nut SS
1 HP to 15 HP / 150mm 1 Job 19.00
24.20.53 Providing & Fixing of Stud for Suction
1 HP to 15 HP / 150mm 1 Job 24.00
24.20.54 Providing & Fixing of Top Bush & Top Sleeve
1 HP to 5 HP /100mm 1 Job 264.00

262
S.No. Item Unit Rate in
Rs.
3 HP to 15 HP / 150mm 1 Job 32.00
24.20.55 Providing & Fixing of Pump intermediate bush &
sleeve
1 HP to 5 HP /100mm 1 Job 255.00
3 HP to 15 HP / 150mm 1 Job 312.00
24.20.56 Providing & Fixing of Pump stainer
1 HP to 5 HP /100mm 1 Job 101.00
3 HP to 15 HP / 150mm 1 Job 139.00
24.20.57 Providing & Fixing of center D O
1 HP to 5 HP /100mm 1 Job 161.00
3 HP to 15 HP / 150mm 1 Job 330.00
24.20.58 Providing & Fixing of New rotor
1 HP (100 mm dia) 1 Job 4904.00
2 HP ( 100 mm dia) 1 Job 5281.00
3 HP (100 mm dia) 1 Job 5941.00
4 HP ( 100 mm dia) 1 Job 6507.00
5 HP (100 mm dia) 1 Job 7073.00
3 HP ( 150 mm dia) 1 Job 7921.00
4 HP ( 150 mm dia) 1 Job 8016.00
5 HP ( 150 mm dia) 1 Job 8204.00
6 HP (150 mm dia) 1 Job 8770.00
Above 6.0 to7.5 HP (150 mm ) 1 Job 9996.00
Above 7.5 to 10 HP (150 mm ) 1 Job 11033.00
Above 10.0 to 12.5 HP (150 mm) 1 Job 15088.00
Above 12.5 to 15 HP (150 mm ) 1 Job 16974.00
24.20.59 Providing & Fixing of Adapter Piece
1 HP to 5 HP /100mm 1 Job 170.00
3 HP to 15 HP / 150mm 1 Job 236.00
24.20.60 Providing & Fixing of Water drain plug
1 HP to 5 HP /100mm 1 Job 38.00
3 HP to 15 HP / 150mm 1 Job 48.00
24.20.61 Providing & Fixing of Cable Guard
1 HP to 5 HP /100mm 1 Job 111.00
3 HP to 15 HP / 150mm 1 Job 139.00
24.20.62 Labour only for stator servicing :-
1 HP - 5 HP / 100 mm 1 Job 472.00
3 HP - 5 HP / 150mm 1 Job 490.00
5 HP - 10 HP / 150mm 1 Job 613.00
10 HP - 15 HP / 150mm 1 Job 708.00
24.20.63 Labour only for Rotor Balancing :-
1 HP - 5 HP / 100 mm 1 Job 754.00
3 HP - 5 HP / 150mm 1 Job 849.00
5 HP - 10 HP / 150mm 1 Job 1037.00
10 HP - 15 HP / 150mm 1 Job 1320.00

263
S.No. Item Unit Rate in
Rs.
24.20.64 Labour only for Impeller Brass welding & Turning 1 Job 283.00
24.20.65 Labour only for Motor Rotor sleeve turning & 1 Job 613.00
grinding
24.20.66 Labour only for Flange stud Welding 1 Job 38.00
24.20.67 Labour only for Motor opening, servicing, fitting & 1 Job 425.00
testing
24.20.68 Labour only for Copper welding, Turning & Grinding 1 Job 754.00
to enduring of rotor
24.20.69 Labour only for Welding Turning key way cutting of 1 Job 377.00
coupling side of rotor
24.20.70 Labour only for Pump opening & fitting 1 Job 377.00

REPAIRING OF CONTROL PANEL

24.20.71 Providing & Fixing of Relay unit L&T Type 1 Job 561.00
24.20.72 Providing & Fixing of Relay unit BCH Type 1 Job 1269.00
24.20.73 Providing & Fixing of Contacter L&T Type - 16 Amp 1 Job 1080.00
24.20.74 Providing & Fixing of Contacter BCH Type - 16 Amp 1 Job 1551.00
24.20.75 Providing & Fixing of Contacter BCH Type - 25 Amp 1 Job 2023.00
24.20.76 Providing & Fixing of Kit Point Set L&T Type 1 Job 420.00
24.20.77 Providing & Fixing of Kit Point Set BCH Type -16 1 Job 797.00
Amp
24.20.78 Providing & Fixing of Kit Point Set BCH Type - 25 1 Job 608.00
Amp
24.20.79 Providing & Fixing of No Volt Coil L&T Type 1 Job 420.00
24.20.80 Providing & Fixing of No Volt Coil BCH Type 1 Job 420.00
24.20.81 Providing & Fixing of Timer Set L&T Type 1 Job 1269.00
24.20.82 Providing & Fixing of Timer Set BCH Type 1 Job 1551.00
24.20.83 Providing & Fixing of Auxillary Switch 1 Job 523.00
24.20.84 Providing & Fixing of Timer Coil 1 Job 391.00
24.20.85 Providing & Fixing of Amp meter (Round) 1 Job 123.00
24.20.86 Providing & Fixing of Volt Meter (Round) 1 Job 123.00
24.20.87 Providing & Fixing of Amp meter (Square) 1 Job 170.00
24.20.88 Providing & Fixing of Volt Meter (Square) 1 Job 170.00
24.20.89 Providing & Fixing of ON Switch 1 Job 85.00
24.20.90 Providing & Fixing of Off Switch 1 Job 85.00
24.20.91 Providing & Fixing of Terminal Plate 1 Job 137.00
24.20.92 Providing & Fixing of Indicator Lamp 1 Job 33.00
24.20.93 Providing & Fixing of MCB -Single Pole - 16 -25 1 Job 108.00
Amp

264
S.No. Item Unit Rate in
Rs.
24.20.94 Providing & Fixing of MCB -Three Pole - 32 Amp 1 Job 647.00
24.20.95 Providing & Fixing of MCB -Three Pole - 40 Amp 1 Job 608.00
24.20.96 Providing & Fixing of MCB -Three Pole - 63 Amp 1 Job 655.00
24.20.97 Providing & Fixing of Capacitor 36 MFD 1 Job 326.00
24.20.98 Providing & Fixing of Capacitor 50 MFD 1 Job 326.00
24.20.99 Providing & Fixing of Capacitor 120-150 MFD 1 Job 344.00
24.20.100 Providing & Fixing of Capacitor 200-250 MFD 1 Job 363.00
24.20.101 Providing and fixing of suitable rating ISI marked
wired with lugs & sleeves in place of burnt wiring of
control panel.
1 HP - 3 HP (Single Phase) 1 Job 406.00
3 HP - 5 HP ( Three Phase) 1 Job 500.00
5 HP - 10 HP ( Three Phase) 1 Job 689.00
10 HP - 15 HP ( Three Phase) 1 Job 877.00
REPLACEMENT OF FLAT COPPER CABLE
24.20.102 Providing and fixing of ISI marked PVC insulated
three core flat copper cable.
1.5 sq mm 1 Job 43.00
2.5 sq mm 1 Job 66.00
4.0 sq mm 1 Job 97.00
6.0 sq mm 1 Job 142.00

HORIZONTAL / INCLINED / VERTICAL


BORES INSIDE THE DUG WELL

24.20.103 Labour charges for lowering and taking out the drilling Each 3460.00
machine mast assembly, drill rods and drilling
equipments etc. and installation of drilling machines
mast inside the dug well Complete work.

24.20.104 Drilling of Horizontal / Inclined / Vertical bore hole of Per 908.00


115 mm diameter inside existing dug well up to desired meter
depth with insertion of suitable perforated
PVC/HDPE/ G.I..Pipe provided by department in all
types of strata i.e. Soil, Rock, Hard Rock including all
works pertaining to drilling such as transportation,
installation and removal of drilling machine in side
dug well etc. complete.

SINGLE/ THREE PHASE SUBMERSIBLE/


CENTRIFUGAL MOTOR PUMP SET
24.20.105 Supplying & Installation of Energy efficiant five star

265
S.No. Item Unit Rate in
Rs.
BEE rating ISI Marked required capacity single
phase, 50 Hz, 220V, deep well submersible pump
Stainless Steel body, suitable for 4"/6" tube well with
Contral Panel Starter suitable for Submersible pump
with dry run protection, connections, including
clamps, bore cap etc. as required as per specifications
but excluding pipe, SS/ Nylon wire rope and
connection cable.
(i) 0.5 H.P. with 6 to 7 stages, Head Mt. 46-13 Discharge Each 20553
LPM 10-55
(ii) 1 H.P. with upto 5 stages, Head Mt. 35-15 Discharge Each 21716
LPM 40-125
(iii) 1 H.P. with 7 to 8 stages, Head Mt. 61-18 Discharge Each 22085
LPM 25-90
(iv) 1 H.P. with 10 to 11 stages, Head Mt. 74-21 Discharge Each 22879
LPM 15-55
(v) 1 H.P. with 12 to 14 stages, Head Mt. 91-28 Discharge Each 23588
LPM 10-45
(vi) 1.5 H.P. with up to 6 stages, Head Mt. 42-17 Each 25795
Discharge LPM 65-150
(vii) 1.5 H.P. with up to 7 to 8 stages, Head Mt. 56-21 Each 26504
Discharge LPM 40-125
(viii) 1.5 H.P. with to 10 to 11 stages, Head Mt. 84-26 Each 26051
Discharge LPM 25-90
(ix) 1.5 H.P. with 16 to 17 stages, Head Mt. 114-33 Each 26135
Discharge LPM 15-55
(x) 1.5 H.P. with 18 to 20 stages, Head Mt. 130-41 Each 28064
Discharge LPM 10-45
(xi) 2 H.P. with up to 7 to 8 stages, Head Mt. 56-16 Each 29505
Discharge LPM 65-205
(xii) 2 H.P. with to 10 to 11 stages, Head Mt. 77-30 Each 29760
Discharge LPM 40-125
(xiii) 2 H.P. with 14 to 15 stages, Head Mt. 114-36 Each 28569
Discharge LPM 25-90
(xiv) 2 H.P. with 20 to 22 stages, Head Mt. 147-42 Each 28144
Discharge LPM 15-55
(xv) 2 H.P. with 25 stages, Head Mt. 163-58 Discharge Each 32738
LPM 10-45
(xvi) 3 H.P. with 10 to 12 stages, Head Mt. 84-23 Each 31660
Discharge LPM 65-205
(xvii) 3 H.P. with 15 to 17 stages, Head Mt. 119-45 Each 32614
Discharge LPM 40-125
(xviii) 3 H.P. with 20 to 22 stages, Head Mt. 167-51 Each 31320
Discharge LPM 25-90

266
S.No. Item Unit Rate in
Rs.
24.20.106 Supplying & Installation of Energy efficiant five star BEE
rating ISI Marked required capacity of Three Phase, 50 Hz,
415V, deep well submersible pump Steel body, suitable for
6"tube well with Control Panel Starter suitable for
Submersible pump with dry run protection, single phase
preventer, connections, including clamps, bore cap etc. as
required as per specifications but excluding pipe and
connection cable.
(i) 3 H.P. with up to 6 stages, Head Mt. 55-7 Discharge Each 35576
LPM 60-510
(ii) 5 H.P. with up to 5 stages, Head Mt. 55-13 Discharge Each 39914
LPM 120-510
(iii) 5 H.P. with 8 to 9 stages, Head Mt. 83-32 Discharge Each 42638
LPM 60-270
(iv) 5 H.P. with 10 to 11 stages, Head Mt. 101-40 Each 45020
Discharge LPM 60-270
(v) 7.5 H.P. with 8 to 10 stages, Head Mt. 117-31 Each 49845
Discharge LPM 60-420
(vi) 7.5 H.P. with 13 to 14 stages, Head Mt. 129-52 Each 56699
Discharge LPM 60-270
(vii) 7.5 H.P. with 15 stages, Head Mt. 138-60 Discharge Each 58883
LPM 60-270
(viii) 10 H.P. with 16 stages, Head Mt. 147-64 Discharge Each 62060
LPM 60-270
(ix) 10 H.P. with 20 stages, Head Mt. 184-80 Discharge Each 68414
LPM 60-270
24.20.107 Supplying and laying of submersible flat cable ISI
marked 3 core copper wire of suitable size with proper
clamping of approved make.
(i) 2.5 Sq.mm.multi strand Per 119
Mtr
(ii) 4.0 Sq.mm.multi strand Per 167
Mtr
(iii) 6.0 Sq.mm.multi strand Per 247
Mtr
(iv) 10.0 Sq.mm.multi strand Per 398
Mtr
24.20.108 Supplying and laying of approved Make Nylon rope Per 60
12mm thick complete with binding for support of Mtr
pump and motor
24.20.109 Supplying and laying of approved make stainless steel Per 137
wire rope 6 mm thick complete with binding for Mtr
support of pump and motor
24.20.110 Supplying and Installation of approved Make required
capacity single phase, 50 Hz, 220V, Centrifugal

267
S.No. Item Unit Rate in
Rs.
Mono-block pump self priming, with Starter,
connections, base channel foundation etc. as required
as per specifications but excludding Pipe and
connection cable.
(i) 1 H.P. Head Mt.6-30, Discharge LPH 2400-900 Each 11803
(ii) 1 H.P. Head Mt.21-45, Discharge LPH 1800-400 Each 7330
(Domestic Model)
24.20.111 Supplying & Installation of approved Make required
capacity single phase, 50 Hz, 240V, Centrifugal
Mono-block pump, with Starter, connections, base
channel foundation etc. as required as per
specifications but excluding Pipe and connection
cable.
(i) 1.0 H.P. Head Mt.3-24, Discharge LPH 27000-1500 Each 11315
(ii) 1.5 H.P. Head Mt.3-21, Discharge LPH 39600-6000 Each 13592
(iii) 2.0 H.P. Head Mt.3-18, Discharge LPH 48600-3000 Each 15088
24.20.112 Supplying & Installation of approved Make required
capacity 3 phase, 50 Hz, 415V, Centrifugal Mono-
block pump, with Starter,i/c single phase preventor,
connections, base channel foundation etc. as required
as per specifications but excluding Pipe and
connection cable.
(i) 3.0 H.P. Head Mt.6-15, Discharge LPM 740-465 Each 19076
(ii) 5.0 H.P. Head Mt.6-33, Discharge LPM 1380-450 Each 23370
(iii) 7.5 H.P. Head Mt.24-37, Discharge LPM 780-320 Each 29917
24.20.113 Supplying & Installation of Five star BEE rating ISI
Marked required capacity of Three phase, 50 Hz,
415V, Open well Submersible pump, with Control
Panel Starter with Dry Run Protection, single phase
preventer, connections, etc. as required as per
specifications but excluding pipe and connection
cable.
(i) 3.0 H.P. Head Mt.15-24, Discharge LPM 615-195 Each 22252
(ii) 5.0 H.P. Head Mt.15-24, Discharge LPM 930-420 Each 23917

268
ANNEXURE-1
ISSUE RATES OF ISI MARK HAND PUMPS.
G.I. RISER, G.I. CASING & UPVC CASING PIPES FOR
PREPARATION OF ESTIMATES ONLY.

S.No. Item Unit Rate in Rs.


1 ISI mark India mark-II deep well hand pump Each 6709.00
complete with 10 Nos. MS connecting rods. (12 mm
x 3 M long) Normal stand assembly .
2 ISI mark India mark-II deep well hand pump Each 6813.00
complete with 10 Nos. MS connecting rods. (12 mm
x 3 M long) telescopic stand assembly .
3 ISI mark India mark-II extra deep well hand pump Each 9826.00
complete with 20 Nos. MS connecting rods. (12 mm
x 3 M long) 2 counter weight lectrogalvanized &
passivated normal stand assembly .
4 ISI mark India mark-II extra deep well hand pump Each 9964.00
complete with 20 Nos. MS connecting rods. (12 mm
x 3 M long) 2 counter weight electrogalvanized &
passivated telescopic stand assembly .
5 ISI Mark 32 mm dia. G.I. riser pipe in 3 meter Meter 202.00
length socketed on one end as per I.S. 1239 (Part I)
1990 up-to- date amendments and socket as per I.S.
2062/1990 up-to-date amendment.
6 ISI marked G.I. casing pipe (Plain) medium class in
4 to 7 meters length one end fitted with socket as per
I.S.: 1239 (Part-2) 1992 with IV th revision ( Up-to-
date amendments).
100 mm dia Meter 695.00
125 mm dia Meter 927.00
150 mm dia Meter 1116.00
7 ISI marked UPVC casing pipe Confirming to IS
12818/92 (with up-to-date amendments).
Screen pipes with ribs 100 mm dia Meter 392.00
Screen pipes with ribs 150 mm dia Meter 693.00
Screen pipes with ribs 200 mm dia Meter 1098.00
CM casing pipes 100 mm dia Meter 284.00
CM casing pipes 125 mm dia Meter 454.00
CM casing pipes 150 mm dia Meter 488.00
CM casing pipes 200 mm dia Meter 923.00
CS casing pipes 150 mm dia Meter 424.00
CS casing pipes 200 mm dia Meter 754.00

269
ANNEXURE-2
STRATA - CHART

District .......................................... Block ..........................Panchayat…………………


Name of Revenue village............................... Name of habitation .......................
Name of Contractor ........................... …………… Registration no. of machine
Agreement No. ...................................Work Order No..........................................
Date of starting of Tube well construction ............................................................
Date of completion of tube well construction ......................................................
Name of Sub-Engineer in charge of work .............................................................
Measurement Book Number........................................
Exact location of drilling …………………………………………..
G L Details
Depth Strata 1. Type of tube well---------------------------
2 .Diameter of tube well --------------mm
3. Total depth of tube well ---------------mt.
4. Details of casing pipe
Type (G.I/ UPVC/ BLANK/SLOTTED)
Diameter ………….mm
Length ………meter
5. Static water level in the tube well -------mt.
6. Type of pump installed ----------------
7. Length of riser pipe installed
Type (G.I / UPVC) -----------------mt.
8. Yield of tube well ---------------
9. Draw down at above yield ----------mt.

Signature of contractor Signature of Signature of


Sub-Engineer Assistant Engineer
Office ………… Office………….

270
ANNEXURE-3

GEOPHYSICAL RESISTIVITY SURVEY REPORT

1. District .......................................... Block ..........................Panchayat…………………

2. Name of village........................... Name of habitation .....................

3. Name of Hydrogeologist.........................Registration no. & Date of Validity……….

4. Agreement No & Date. ........................Work Order No.................No. of Survey


alloted.........................

5. Date of Survey: - ......................................

6. Name of PHED Person (Mechanic/Sub Eng./DC/BC):

7. Model No & Make of Resistivity meter used for sounding...................................


8. Resistivity Survey Purpose:-.. HP/PWSS
9. Toposheet No/HGM No.: - -
10. Geomorphology of the area :- Valley/PLW/PLM/PLU/PPS
11. Geological Succession of the area under investigation :- Alluvium/Basalt/ Granite/others
12. Hydrogeology of the area:- River system following & Static water table

13. Details of the Resistivity Survey : No. of VES- 03 (Interpretation by Schlumberger


method)

Vertical Latitude / App. Resistivity of layer in Thickness of layer in Total


Electric Longitude ohm (m) (m) depth
Sounding of VES (m)
data ρ4(
ρ1 ( in ρ2( in ρ3( in
in
Ohm- Ohm- Ohm- h1 h2 h3 H
Ohm- h4
m) m) m)
m)
VES No. I
VES No. II
VES No.
III

Subsequently, the above interpretation on the layers identified are geologically Presented in
the following sequence:

271
15. Recommended site :-

i. Location of Site: - --------- Longitude E: ------------- Latitude N: - ----------


ii. Direction of site from Village………….

S.No Characteristics:- Sub- Depth below Ground Level Aquifer Shallow/Deeper


Surface Strata (m) ( I, II, III) Aquifer
(Litholog) expected.
From To

iii. Type of drilling machine :-D.T.H./combination bore/Gravel Pack


iv. Diameter of T/W:-
v. Depth of Tube well :- ……mt
vi. Expected Casing (Compact & Perforated) requirement : - ----to----mt / ---to--mt/
---to --mt.

vii. Expected Yield :- ………LPH (Liter Per Hour)


viii. Remarks :
ix. Suggestive Recharge Structure :-
16. Enclosures :-
(i) Photocopy of Toposheet / HGM Map of area.
(ii) Map (Not to scale) showing the location of Survey Point (to be attached separately) in
A4 size sheet.
(iii) Location site plan of three sounding sites
(iv) Reading chart of Sounding
(v) Depth probe graph /curves.
(vi) Photograph of site with installed instrument
(vii) Detail of Private Tube well nearby:

S. Location of Tube well Depth (m) Yield (LPH)


No.

Signature of AE/Sub Eng. / DC( Hydrologist) Signature of Geo-hydrologist & Seal

272
ANNEXURE-4
YIELD TEST OF TUBE WELLS.

District .......................................... Block ..........................Panchayat…………………

Name of Revenue village............................... Name of habitation .......................

Name of contractor ...............................................................................................

Agreement No. .................................. Work order No........................................

Date of yield test ...................................................................................................

Diameter of tube well .......................... Depth of tube well .................................

Static water level in tube well ................................................................................

Type and K.W. of pumping set used for yield test ..............................................

Type of measuring device used for measurement of discharge ...........................

Depth at which the pumping set installed.............................................................

Time at which the yield test started ....................................................................

Sketch of casing pipe


with measuring point

Measuring Point (pezometer)

Casing

Ground level

273
Pump Test Results

S. Time Step Durati Disch- Water level Draw Down Remark


No No. on of arge (cu. in the tube in meters =
. step mtr. / well static water
(hrs.) hr.) measured level (-)
from ground water level
level at the at the end of
end of each pumping at
step in meters given time
1
2
3
4

Note :- Discharge at static water level shell be taken on dependable yield of Tube
well.

Signature of Signature of Signature of


Contractor Sub-Engineer Assistant Engineer

274
PART-(C)

SEWERAGE MAINTENANCE
WORKS

275
GENERAL NOTES
SEWERAGE MAINTENANCE

1. Contractor is bound to follow the guide line of CPHEEO manual on sewerage


& sewage treatment system ( Part-B) issued by Ministry of Urban Devlopment,
New Delhi w.e.f. November 2013
2. The tools, plant, machinery and pumps required for cleaning should be arranged
by the contractor at his own cost.
3. The payment will be made after successful testing of line only. No payment will
be made for testing work in pieces.
4. No payment will be made for dewatering whatsoever involve in cleaning of
manhole & sewer line. The payment of Dat (temporary plugging of chambers)
will be made for cleaning of chamber only in accordance with volume of pipes,
manholes and drains. The rates of Dat are included in the SOR.
5. The manhole cover for replacement will be issued from the store & no extra
payment will be made for loading, unloading and transportation of manhole
cover with frame upto the work site.
6. The contractor shall be fully and solely responsible for making all safety
arrangements pertaining to the work such as barricading, lighting , arrangement
of gas masks, safety belts and oxygen cylinder etc.
7. Shifting of silt and garbage will be done as per the direction of the Engineer-in-
charge.
8. Providing and fixing of CI/SFRC manhole cover with frame may be replaced(if
required) but the cover shall be as per ISI mark only. The payment will be made
as per rates applicable in the USOR.
9. The rates for various works given in the unified schedule of rates include
contractor profit over head expenses, water and T&P expenses.
10. Some poisonous & inflammable gases are observed in deep sewers manholes, to
prevent any disaster due to trance gases, the safety of cleaning staff is the
responsibility of the contractor.
11. The department is not responsible for any accident during cleaning of sewer
line. The contractor is fully responsible for any compensation to labour or for
any legal action arising due to the accident.

10. This USOR contains the rates of all the items without GST. GST shall be
paid separately as per prevailing government norms as claimed by the
contractor in his bill.
All the estimates based on this USOR will include GST as an extra amount
as per prevailing rates on the sum of the estimate to arrive at the gross
amount.

276
CHAPTER XXV

SEWERAGE MAINTENANCE WORKS

277
CHAPTER- XXV
SEWERAGE MAINTENANCE

S.No. Item Unit Rates


in Rs.
25.1 Lifting & Placing of manhole cover during
cleaning of chocked sewer line & manhole.
i. SFRC 500 mm dia size Each 26.00
ii. SFRC 560 mm dia size Each 32.00
iii SFRC 600 mm dia size Each 39.00
iv SFRC 450x900 mm size Each 45.00
v SFRC 600x450 mm size Each 26.00
vi SFRC 600x600 mm size Each 32.00
vii SFRC 600x900 mm size Each 39.00
viii SFRC 1.2 x 0.9 mtr. size Each 84.00
ix C.I. 560 mm dia size Each 39.00
x C.I. 1.2 x 0.9 mtr. Size Each 96.00
25.2 Lifting & placing of manholes cover & frame
including dismantling of existing C.C. coping
during Raising of manholes ( civil work to be
paid separately)
i. SFRC 500 mm dia size Each 72.00
ii. SFRC 560 mm dia size Each 85.00
iii SFRC 600 mm dia size Each 97.00
iv SFRC 450x900 mm size Each 117.00
v SFRC 600x450 mm size Each 72.00
vi SFRC 600x600 mm size Each 85.00
vii SFRC 600x900 mm size Each 97.00
viii SFRC 1.2 x 0.9 mtr. size Each 169.00
ix C.I. 560 mm dia size Each 97.00
x C.I. 1.2 x 0.9 mtr. Size Each 201.00
25.3 Replacement of SFRC manhole cover with Kg. 20.00
frame or without frame of approved quality of
any shape & size with cost of material & labour
(civil work to be paid separately)
25.4 Labour only for replacement of SFRC manhole Kg` 2.00
cover with frame or without frame of any shape
& size (civil work to be paid separately)
25.5 Making arrangement for dat (plugging of
sewer) including all required material such
as steel plate, manila rope, gunny bags, earth
etc. or by and other plugging device with all
required T & P and safety equipment
including dewatering.

278
S.No. Item Unit Rates
in Rs.
25.5.1 Depth upto 1.5 m
i. 100 mm dia Each 607.00
ii. 150 mm dia Each 811.00
iii. 200 mm dia Each 814.00
iv 250 mm dia Each 818.00
v 300 mm dia Each 822.00
(a) Extra rate of depth 1.5m to 3m or part
100 mm dia to 300 mm Each 39.00
(b) Extra rate of depth 3m to 4.5 or part
100 mm dia. to 300 mm Each 78.00
(c) Extra rate of depth 4.5 m to 6m or part
100 mm dia to 300 mm Each 116.00
25.5.2 Depth upto 1.5 m for RCC Sewer.
i. 350 mm dia Each 1108.00
ii. 400 mm dia Each 1115.00
iii. 450 mm dia Each 1122.00
iv. 500 mm dia Each 1130.00
(a) Extra rate of depth 1.5 m to 3m or part
350 mm to 500 mm dia Each 51.00
(b) Extra rate of depth 3m to 4.5 m or part
350 mm to 500 mm dia Each 102.00
(c) Extra rate of depth 4.5m to 6m or part
350 mm dia to 500 mm Each 153.00
(d) Extra rate of depth 6m to 7.5 m or part
350 mm dia to 500 mm Each 204.00
(e) Extra rate of depth 7.5m to 9m or part
350 mm dia 500 mm Each 306.00
25.5.3 Depth upto 1.5 m for RCC Sewer.
i. 600 mm dia Each 1577.00
ii. 700 mm dia Each 1598.00
iii. 800 mm dia Each 1623.00
iv. 900 mm dia Each 1650.00
v. 1000 mm dia Each 1679.00
(a) Extra rate of depth. 1.5m to 3m to or part
600 mm to 1000 mm dia Eact 71.00
(b) Extra rate of depth. 3m to 4.5 m to or part
600 mm to 1000 mm dia Each 142.00
(c) Extra rate of depth. 4.5 m to 6m to or part
600 mm dia to 1000 mm Each 213.00
(d) Extra rate of depth. 6m to 7.5m or part
600 mm dia to 1000mm Each 284.00
(e) Extra rate of depth. 7.5m to 9m or part
600 mm dia to 1000 mm Each 506.00

279
S.No. Item Unit Rates
in Rs.
25.5.4 Depth upto 1.5 m for RCC Sewer.
i. 1200mm dia Each 2239.00
ii. 1400 mm dia Each 2344.00
iii. 1600 mm dia Each 2440.00
iv. 1800 mm dia Each 2548.00
(a) Extra rate of depth 1.5 to 3m to or part
1200 mm to 1800 mm dia Each 93.00
(b) Extra rate of depth 3m to 4.5 m to or part
1200 mm to 1800 mm dia Each 186.00
(c) Extra rate of depth 4.5m to 6m to or part
1200 mm to 1800 mm dia Each 279.00
(d) Extra rate of depth 6m to 7.5 m or part
1200 mm to 1800 mm dia Each 372.00
(e) Extra rate of depth 7.5 m to 9m or part
1200 mm to 1800 mm dia Each 559.00
(f) Extra rate of depth 9m to 10.5m or part
1200 mm to 1800 mm dia Each 745.00
(g) Extra rate of depth 10.5 m to 12m or part
1200 mm to 1800 mm dia Each 931.00
25.6 Cleaning of Silt, sludge brick bats, polythene
bags, garbage etc. from chocked sewer
manholes / sewer drains & Nallahs/ wet well
of SPH/ Anaerobic & Facultative Pond of
STP with all required T&P such as bucket,
manila rope, and all required safety
equipment such as safety belt, gas mask,
oxygen cylinder etc. including disposal of silt/
sludge upto 50 mtr lead & 1.5 mtr. lift as
directed by Engineer-in-Charge including
dewatering but excluding dat (plugging of
sewer pipe line)
Depth up to 1.5 mtr Cu.M 441.00
(a) Extra rate for depth 1.5 m to 3m or part Cu.M 22.00
(b) Extra rate for depth 3m to 4.5 m or part Cu.M 44.00
(c) Extra rate for depth 4.5 m to 6m or part Cu.M 50.00
(d) Extra rate for depth 6m to 7.5 m or part Cu.M 55.00
(e) Extra rate for depth 7.5m to 9m or part Cu.M 62.00
(f) Extra rate for depth 9m to 10.5 m or part Cu.M 66.00
(g) Extra rate for depth 10.5 m to 12m or part Cu.M 77.00
25.7 Cleaning of Silt, sludge brick bats, polythene
bags, garbage etc. from chocked sewer line
with all required T&P and Safety equipment
such as bucket, manila rope, safety belt, gas
mask, oxygen cylinder etc. including disposal

280
S.No. Item Unit Rates
in Rs.
of silt, sludge upto 50m lead & lift up to
1.5mtr. as directed by Engineer-in- Charge
including dewatering but excluding dat
(plugging of sewer pipe line)
25.7.1 150 mm dia Per Mtr. 37.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 2.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 4.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 6.00
25.7.2 200 mm dia Per Mtr. 45.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 2.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 5.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 7.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 9.00
25.7.3 250 mm dia Per Mtr. 53.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 3.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 5.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 8.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 11.00
25.7.4 300 mm dia Per Mtr. 64.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 3.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 6.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 10.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 13.00
25.7.5 350 mm dia RCC Per Mtr. 227.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 11.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 23.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 34.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 45.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 68.00
25.7.6 400 mm dia RCC Per Mtr. 273.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 14.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 27.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 41.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 55.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 82.00
25.7.7 450 mm dia RCC Per Mtr. 314.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 16.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 31.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 47.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 63.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 84.00
25.7.8 500 mm dia RCC Per Mtr. 341.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 17.00

281
S.No. Item Unit Rates
in Rs.
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 34.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 52.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 68.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 102.00
(a) Extra rate for depth 9m to 10.5m or part Per Mtr. 136.00
25.7.9 600 mm dia RCC Per Mtr. 409.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 20.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 41.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 61.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 82.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 123.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 164.00
25.7.10 700 mm dia RCC Per Mtr. 491.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 25.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 49.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 74.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 98.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 147.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 196.00
25.7.11 750 mm dia RCC Per Mtr. 541.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 26.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 55.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 81.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 108.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 162.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 216.00
25.7.12 800 mm dia RCC Per Mtr. 547.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 30.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 59.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 89.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 119.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 183.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 245.00
25.7.13 900 mm dia RCC Per Mtr. 682.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 34.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 68.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 102.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 136.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 205.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 273.00
25.7.14 1000 mm dia RCC Per Mtr. 781.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 39.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 78.00

282
S.No. Item Unit Rates
in Rs.
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 116.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 156.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 234.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 312.00
(g) Extra rate for depth 10.5m to 12m or part Per Mtr. 390.00
25.7.15 1200 mm dia RCC Per Mtr. 933.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 47.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 93.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 140.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 187.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 280.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 373.00
(g) Extra rate for depth 10.5m to 12m or part Per Mtr. 467.00
25.7.16 1400 mm dia RCC Per Mtr. 1078.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 54.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 108.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 162.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 216.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 323.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 431.00
(g) Extra rate for depth 10.5m to 12m or part Per Mtr. 539.00
25.7.17 1600 mm dia RCC Per Mtr. 1239.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 62.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 124.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 186.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 248.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 371.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 496.00
(g) Extra rate for depth 10.5m to 12m or part Per Mtr. 619.00
25.7.18 1800 mm dia RCC Per Mtr. 1425.00
(a) Extra rate for depth 1.5 m to 3m or part Per Mtr. 71.00
(b) Extra rate for depth 3m to 4.5 m or part Per Mtr. 142.00
(c) Extra rate for depth 4.5 m to 6m or part Per Mtr. 213.00
(d) Extra rate for depth 6m to 7.5 m or part Per Mtr. 285.00
(e) Extra rate for depth 7.5m to 9m or part Per Mtr. 427.00
(f) Extra rate for depth 9m to 10.5m or part Per Mtr. 570.00
(g) Extra rate for depth 10.5m to 12m or part Per Mtr. 713.00
25.8 Removing of all weeds and other growth Sq M 20.00
with roots i/c refused material such as
polythene, cloths, algae etc. from facultative
pond of STP and disposal up to 50 mtr lead
and 1.5 mtr lift as directed by Engineer in
Charge including all required T&P, boat

283
S.No. Item Unit Rates
in Rs.
with boatman, bamboo, plunger, cutter,
bucket, rope etc. and all safety equipments
such as safety belt, gas mask, oxygen cylinder
etc.
25.9 Carriage of desilted sludge & other material
from sewage components by mechanical
transport including loading unloading &
stacking etc.
1. Distance 1 km Cum 136.00
2. Distance 2 km Cum 155.00
3. Distance 3 km Cum 174.00
4. Distance 4 km Cum 192.00
5. Distance 5 km Cum 210.00
6. Beyond 5km upto 10km. add per km Cum 14.00
7. Beyond 10km. upto 20km. add per km. Cum 12.00
8. Beyond 20km. add per additional Cum 10.00