You are on page 1of 3

PILE CAP DESIGN FOR 10 NOS 500 mm DIA 20 M piles (E-5)

Vertical Loading
Dia of Pile 0.500 m
Size of pedestal 0.600 0.6 m
SPACING BETWEEN PILES (M) 1.250 m (min=3xd)

Unfactored Load (DL+LL) 3019.841 KN


Unfactored Moment Mx 2.000 KN-m
Unfactored Moment My 361.000 KN-m

Allowable Pile Capacity 375.000 KN


Compressive strength of Concrete 25.000 N/mm2
Reinforcement Grade 500.000 N/mm2
Depth of pile cap D 1.000 m (min= pile spacing/2)
Effective depth d 0.925 m
width of pile cap b 3.400 m
Length of Pile Cap l 4.756 m
Total Unfactored Load 3019.841 KN
Nos of Pile Required 8.053
Pile Provided 10.000

Distances of Piles from Centre of Pile Cap


dx1 -1.250 m
dx2 1.250 m
dx3 -1.250 m
dx4 1.250 m
dx5 -1.250 m
dx6 1.250 m
dx7 0.000 m
dx8 0.000 m
dx9 0.000 m
dx10 0.000 m
Iy 9.375
dy1 1.250 m
dy2 1.250 m
dy3 0.000 m
dy4 0.000 m
dy5 -1.250 m
dy6 -1.250 m
dy7 1.875 m
dy8 0.625 m
dy9 -0.625 m
dy10 -1.875 m
Ix 14.063

Maximum Load on Piles


P1 254.029 KN safe
P2 350.295 KN safe
P3 253.851 KN safe
P4 350.117 KN safe
P5 253.673 KN safe
P6 349.940 KN safe
P7 302.251 KN safe
P8 302.073 KN safe
P9 301.895 KN safe
P10 301.717 KN safe
Factored Load on Piles
Pu1 381.043 KN
Pu2 525.443 KN
Pu3 380.776 KN
Pu4 525.176 KN
Pu5 380.509 KN
Pu6 524.909 KN
Pu7 453.376 KN
Pu8 453.109 KN
Pu9 452.843 KN
Pu10 452.576 KN
Steel in X -direction
Distance of Pile Centre from Column Face 0.950 m
Moment at Column Face 1359.319 KNm Mu/bd2 = 0.334 %pt= 0.120

Bottom Ast = 12.000 cm2/m provide 12 dia at 94 c/c


Top Ast = 6 cm2/m (MIN 0.06%) 12 dia at 188 c/c

Steel in Y -direction
Distance of Pile Centre from Column Face 0.325 m
Moment at Column Face 1722.489 KNm Mu/bd2 = 0.5921 %pt= 0.140
Bottom Ast = 14.005 cm2/m provide 12 dia at 81 c/c
Top Ast = 6 cm2/m (MIN 0.06%) 12 dia at 188 c/c

Distance of critical section from pile face 0.925 m

Shear Stress in X -direction


Distance of Pile centre from Column centre 1.250
Distance of column face from critical section 0.925 m
Factored Shear Force 1430.862 KN
Shear force at critical section 1550.100 KN shear check reqd
Shear Stress 0.493 N/mm2 unsafe
Allowable 0.320 N/mm2 for pt%= 0.195
1550.1
Shear Stress in Y -direction
Distance of Pile centre from Column centre 0.625 m
Distance of column face from critical section 0.925 m
Factored Shear Force 1812.971 KN
Shear force at critical section 982.026 KN shear check reqd
Shear Stress 0.312 N/mm2 Safe
Allowable 0.330 N/mm2 for pt%= 0.230
982.026
Check for Punching on Piles

Shear Stress 0.2553 N/mm2 Safe


Permisible stress 1.2500 N/mm2

Column Punching Check


Punching Length (bo) 6.100 m
Punching Shear 0.710 N/mm2 Safe k 1
ß 1
Allowable 1.250 N/mm2 tauc 1.25