Model: 13EKOZD 60 Hz

11EFKOZD 50 Hz

3-Phase Diesel

Marine Generator Set


Engine Features
D Diesel fueled
D Certified by the Environmental Protection Agency
(EPA) to conform to Tier III marine auxiliary
standards
D Three cylinder
D Four cycle
D Closed cooling system
D Heat exchanger
D Electric fuel lift pump
D Lifting eye

Generator Features
D Class H insulation
D Multivoltage adjustability
D 60/50 Hz capability
D Voltage regulation of 1.0%
Generator Weights and Dimensions D Radio suppression

Without With Decision-Makerr 3500 Paralleling


Sound Shield Sound Shield
Controller
Weight, kg (lb.) D A graphical display and pushbutton/rotary selector
Wet 376 (830) 395 (870) dial provide easy, local data access
Dry 363 (800) 381 (840) D Measurements are selectable in metric or English
Length, mm (in.) 984 (38.76) 992 (39.07) units
Width, mm (in.) 563 (22.15) 601 (23.64) D The controller supports Modbusr protocol with
serial bus (RS-485) or Ethernet networks
Height, mm (in.) 682 (26.86) 711 (27.99)
D Scrolling display shows critical data at a glance
D Graphical display of power metering (kW, kVA, V, I,
Generator Ratings PF, and VAR)
D Integrated hybrid voltage regulator providing 0.5%
25_C (77_F) 25_C (77_F)
regulation
Model Series Voltage Hz Amps kW/kVA Ph
D Built-in alternator thermal overload protection
120/280 60 45 13/16.3 3
120/240 60 39 13/16.3 3 Optional Accessories
120/240 60 54 13/13 1
D Aluminum sound shield
13EKOZD D Remote digital gauge (2 or 3 inch)
127/220 60 43 13/16.3 3 D Siphon break
139/240 60 39 13/16.3 3 D Circuit breakers
277/480 60 20 13/16.3 3 Modbusr is a registered trademark of Schneider Electric.

110/190 50 42 11/13.8 3
115/230 50 35 11/13.8 3
115/230 50 48 11/11 1
11EFKOZD 120/208 50 38 11/13.8 3
230/400 50 20 11/13.8 3
240/416 50 19 11/13.8 3
220/380 50 21 11/13.8 3
RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler ISO rating
guideline 2.14. Obtain technical information bulletin (TIB-101) on ratings guidelines for complete
ratings definitions.
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler generator distributor for availability.

G2-182 (13EKOZD 3 PH) 10/14


Application Data
Engine Operation Requirements
Engine Specifications 60 Hz 50 Hz Air Requirements 60 Hz 50 Hz
Type 4 cycle, naturally aspirated Engine combustion air requirements,
Cylinder, quantity 3 L/min. (cfm) 1508 (53.25) 1256 (44.37)
Generator cooling requirements, L/min.
Displacement, L (cu. in.) 1.9 (114)
(cfm) 9203 (325) 7645 (270)
Bore and stroke, mm (in.) 88 x 102 (3.46 x 4.02) Max. air intake restriction, in. (mm) H2O 10 (250)
Compression ratio 17:1 Exhaust flow, m3/min. (cfm) 1.4 (49) 1.2 (41)
Combustion system Direct injection Exhaust temp., C (F) at full load 316 (600) 310 (590)
Rated rpm 1800 1500 Max. allowed exhaust back pressure,
kPa (mm H2O) 6 (612) 5 (510)
Max. power at rated rpm, HP 24.7 25.5
Fuel Consumption 60 Hz 50 Hz
Governor, type Mechanical
Diesel, Lph (gph) at % load
Frequency regulation, mechanical
governor 100% 3.97 (1.05) 3.29 (0.87)
No load to full load (droop) . . . . . . . 5% 75% 3.08 (0.81) 2.47 (0.65)
Steady state . . . . . . . . . . . . . . . . . . . 0.7%
50% 2.16 (0.57) 1.71 (0.45)
Angular operation
25% 1.35 (0.36) 1.01 (0.27)
Instant (1 min.) . . . . . . . . 35_
Intermittent (30 min.) . . . . . . . . . . . . 25_ Note: The fuel consumption of the 60 Hz model is based on
13EKOZD and the fuel consumption of the 50 Hz model is based on
11EFKOZD.
Engine Electrical
Engine Electrical System 60 Hz 50 Hz Engine Features
Battery, voltage 12 volt
D Switchable between 50 and 60 Hz
Battery charging module 10-amp
D Low oil pressure shutdown
Battery, minimum recommendation 650 CCA @ 0_F
D High engine temperature shutdown
Starter motor 2 kW, 12 V
D Low seawater pressure shutdown

Cooling D Vibromount
D Belt guard
Cooling System 60 Hz 50 Hz
D Disposable oil filter
Capacity, L (qt.), approx. 5.2 (5.53)
D Oil drain valve
Heat exchanger type 2.5 in. dia. x 2 pass
D Air heater circuit for cold starting
Seawater pump type Belt-driven,
10-blade impeller D Disposable fuel filter

Heat rejected to cooling water at rated Generator Features


kW, wet exhaust, kW (Btu/min.) 17.24 (981) 9.62 (547) D Brushless, rotating field design permits power to be obtained from
Engine water pump flow, Lpm (gpm) 56 (14.8) 46 (12.2) stationary leads.

Seawater pump flow, Lpm (gpm) 27.3 (7.2) 22.7 (6.0) D Windings are vacuum impregnated with epoxy varnish for
dependability and long life.
Fuel D Rotors are dynamically balanced to minimize vibration.

Fuel System 60 Hz 50 Hz D Copper windings ensure minimal heat buildup. Insulation meets
NEMA standards for class H insulation.
Fuel shutoff solenoid Electric
D Direct connected to the engine, the generator has sealed precision
Fuel pump Electric ball bearings with a precision-machined steel sleeve in the end
Maximum recommended fuel lift, m (ft.) 1.2 (4.0) bracket to prevent shaft misalignment and extend bearing life.
D Mounted on a drip-proof tray.
Lubrication D Equipped with a twelve-lead reconnectable stator.
Lubricating System 60 Hz 50 Hz
Oil pan capacity with filter, L (qt.) 8.7 (9.2)
Oil pump type Pressure, trochoid pump

G2-182 (13EKOZD 3 PH) 10/14


Application Data
Accessories
Sound Shield
Provides for highly effective silencing, ease of access for
engine/generator servicing, low maintenance, excellent
durability, and safety. The sound shield’s customer
connection panel includes connections for the following:
Decision-Makerr 3500 Controller d Battery (positive and negative)
Provides advanced control, system monitoring, and system d Equipment ground
diagnostics for optimum performance and compatibility. The d Fuel inlet and return
Decision-Makerr 3500 controller uses a patented hybrid voltage
regulator and unique software logic to manage alternator thermal d Seawater inlet
overload protection features normally requiring additional hardware. d Water-cooled exhaust outlet
Additional features include: d Oil drain
D AC Output Voltage Regulator Adjustment. The voltage d Customer load lead access
adjustment provides a maximum adjustment of ±10% of the d Customer interface
system voltage.
D Alarm Silence. The controller can be set up to silence the Siphon Break
alarm horn only when in the AUTO mode for NFPA-110
application or Always for user convenience. Mandatory kit on generators installed below the waterline.
D Alternator Protection. The controller provides generator set Prevents the siphoning of flotation water into the engine.
overload and short circuit protection matched to each alternator
for the particular voltage/phase configuration. Line Circuit Breakers
D Automatic Restart. The controller automatic restart feature Protect the generator from extreme overload.
initiates the start routine and recrank after a failed start attempt.
D Cyclic Cranking. The controller has programmable cyclic Ship-to-Shore Switch
cranking.
D ECM Diagnostics. The controller displays engine ECM fault Allows immediate switching to Kohlerr generator set
code descriptions to help in engine troubleshooting. power or shore power protecting the electrical system
D Engine Start Aid. The configurable starting aid feature provides from the possibility of simultaneous connection of both
customized control for an optional engine starting aid. power sources.
D Event Logging. The controller keeps a record (up to 1000
entries) for warning and shutdown faults. This fault information Remote Digital Gauges
becomes a stored record of system events and can be reset. Allows starting/stopping from a location remote from the
D Historical Data Logging. Total number of successful starts of generator set.
the generator is recorded and displayed.
d 3 in. gauge for J1939
D Integrated Hybrid Voltage Regulator. The voltage regulator
provides ±0.5% no-load to full-load RMS voltage regulation Requires a 76.2 mm (3 in.) dia. hole for mounting.
with three-phase sensing. d 2 in. gauge for Smartcraftt
D Lamp Test. Press the alarm silence/lamp test button to verify Requires a 50.8 mm (2 in.) dia. hole for mounting.
functionality of the indicator lights.
D LCD Display. Adjustable contrast for improving visibility. Remote Connection/Extension Harness
D Measurement Units. The controller provides selection of Provides wiring between the remote digital gauge and the
English or metric displays. ADC connector. Extension limited to a total of four kits
D Power Metering. Controller graphical display provides voltage, and 23 m (75 ft.). Available in 4.6 m (15 ft.) and 7.6 m
current, power factor, kW, kVA, and kVAR. (25 ft.) lengths.
D Programming Access (USB). Provides software upgrades and
diagnostics with PC software tools. 12-Inch Remote Wiring Harness
D Remote Reset. The remote reset function supports
acknowledging and resetting faults and allows restarting of the Equipped with a 12-pin connector on one end that
generator set without going to the master control switch off/reset connects to the standard customer interface connector.
position. Equipped on the other end with leads for connection to
D Run Time Hourmeter. The generator set run time is displayed. customer-supplied wiring.
D Time Delay Engine Cooldown (TDEC). The TDEC provides a
time delay before the generator set shuts down.
D Time Delay Engine Start (TDES). The TDES provides a time
delay before the generator set starts.
D Voltage Selection Menu. This menu provides the capability to
switch the generator output voltage. NOTE: Generator set
output leads may require reconnection.
D Paralleling Functions:
D Bus sensing
D First on logic
D Synchronizing
D Communication based isochronous load sharing
D Droop load sharing
D External controlled load sharing via analog bias signals SmartCraftt is a trademark of Mercury Marine, a division of Brunswick Corporation.

G2-182 (13EKOZD 3 PH) 10/14


KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KOHLERPower.com

Note: Sound shield shown with rear connection panel.


Front connection panel is also available.

ADV-8558-
ADV-8559-
DISTRIBUTED BY:

NOTE: Dimensions in [ ] are inch equivalents.

NOTE: This drawing is provided for reference only and is not


intended for installation planning. Contact your local
distributor for more detailed information.
E 2014 by Kohler Co. All rights reserved.

G2-182 (13EKOZD 3 PH) 10/14