You are on page 1of 318

LA PROTECTION DES CENTRALES ELECTRIQUES

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ GENERALITES SUR LES RESEAUX ELECTRIQUES
¾ LES REDUCTEURS DE MESURE
¾ LES GENERATEURS ELECTRIQUES
¾ LES TRANSFORMATEURS ELECTRIQUES
¾ LES MOTEURS ELECTRIQUES
¾ LE SOUTIRAGE

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ DESCRIPTION D’UN RESEAU ELECTRIQUE

¾ COMPOSANTES SYMETRIQUES

¾ NOMBRES COMPLEXES

¾ CALCUL DES COURANTS DE DEFAUT

¾ REGIME DE NEUTRE

¾ ROLE DES PROTECTIONS


3

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Centrale de production

Interconnexion Transport THT Répartition HT Distribution MT Utilisation BT


400 kV (THT) 220 kV 60 kV 20 kV 0.4 kV

Centrale
de production

Poste THT/THT Poste Source


400/220 kV 60/20 kV

Centrale de production

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Auxiliaires
Diésel

Transformateur
auxiliaire

Réseau

Transformateur
de démarrage

Transformateur
Transformateur
de soutirage
élévateur

Alternateur Evacuation

Transformateur
d’excitation
Autres générateurs

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
L1 L2

Interconnexion
400 kV
JB1A JB1B

JB2A JB2B

JBTA JBTB

Transport
220 kV

< 200 km

L3 L4 6

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Arrivée
Production
Autonome
HT / MT

MT / BT
Autres Process

Utilisation

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Amplitude
90°

180° 0°
360° 0 5ms 10ms 15ms 20ms
t

270°

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Amplitude
90°

180° 0°
360° 0 5ms 10ms 15ms 20ms
t

270°

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Amplitude
90°

180° 0°
360° 0 5ms 10ms 15ms 20ms
t

270°

10

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
V3
V3

a
V1 V1

V2 V2

Réseau triphasé ou Réseau triphasé


EQUILIBRE DESEQUILIBRE
V1 = Vd + Vi + Vo
V2 = a²Vd + aVi + Vo
V3 = aVd + a²Vi + Vo 11

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
aVd a²Vi
Vo Vo Vo
a
Vd Vi
a

a²Vd aVi
Système Système Système
DIRECT INVERSE HOMOPOLAIRE

3Vd = V1+aV2+a²V3 3Vi = V1+a²V2+aV3 3Vo = V1+V2+V3

12

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
V3
V3

a²V3
a²V2 aV2
3Vd

aV3 V1

3Vi aV3

V2 V2

3Vd = V1 + aV2 + a²V3 3Vi = V1 + a²V2 + aV3


13

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾Bien adaptées à la représentation des
grandeurs sinusoïdales

¾A éviter pour les transitoires oscillants ou


non.

¾En pratique, à bannir pour t < 20 ms

¾Pour les alternateurs: approximation des


résultats avec cette méthode + tolérance sur
les données. Simplification par X’d correcte,
car phénomènes à étudier entre 80 et 100 ms.
14

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
X (Inductance L)

Coordonnées cartésiennes

b Z Z = a + jb
ϕ
-R j R
a

Coordonnées polaires

- X (Capacitance C) Z et ϕ

15

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Liaison = Câble + Ligne
X
X X

b Zc d d
Zl
Zl
Ze
R R
a c
b Zc
Zc = a + jb Zl = c + jd
R
a c
Ze = (a + c)
+ j(b + d)
16

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Liaison = Câble + Ligne
Ligne = Liaison - Câble
X X
X

-Zc
b d Zc
Ze R Ze
c Zl
Zc = c + jd
R R
a
Ze = a + jb Ze = (a - c) +
j(b - d) 17

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Sans équivalence physique mais nécessaire pour le
calcul: par exemple 2 liaisons en parallèle

Z1 Z2

Z1 * Z2
Ze =
Z1 + Z2

ou transposition étoile triangle


18

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut triphasé

Zdam

U
U Vn
V Icctri = Zdam
U Icc
Un
Icctri =
√3*Zdam

19

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut monophasé

Zdam Ziam Zoam

V
Icc

3 * Vn 3 * Vn
Icc = =
Zdam+Ziam+Zoam 2 * Zdam + Zoam

20

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut biphasé (loin des sources)
Un
Iccbi = Zdam+Ziam
Zdam Ziam
Loin des sources
U Zdam = Ziam
Icc
Un
Iccbi = 2 * Zdam

√3 Icctri
Iccbi = 2 = 0.866Icctri
21

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut biphasé (proche des sources)
Un
Iccbi = Zdam+Ziam
Zdam Ziam
Zdam = Ziam
U
Zdam=k* Ziam
Icc
Un
Iccbi =(k+1) * Ziam

k√3 Icctri
Iccbi = k+1
22

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Evolution du courant Icctri et Iccbi (proche des sources)

Icc
1,4
1,2
U/Ziam 1
0,8 Iccbi
0,6
Icctri
0,4
0,2
0
0
1
2
3
4
5
6
7
8
9
10
K

23

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
EN PRATIQUE SEULS LES CALCULS DE
DEFAUTS TRIPHASE ET MONOPHASE A LA
TERRE SONT EFFECTUES.

24

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
METHODOLOGIE DE CALCUL DES COURANTS DE DEFAUTS

UN COURANT DE DEFAUT Id SE CALCULE SOUS LA FORME

Id = U (force électromotrice) / (impédance limitant le courant de défaut)

LA TENSION U SE CHOISIT ARBITRAIREMENT, MAIS :

LE COURANT Id CORRESPONDRA A CE NIVEAU DE TENSION DE CALCUL ET DEVRA


DONC ETRE RAMENE AU NIVEAU DE LA TENSION OU LE COURANT DE DEFAUT
SOUHAITE ETRE CONNU :

Id (tension désirée) = Id (tension de calcul) x (tension de calcul / tension désirée)

25

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
METHODOLOGIE DE CALCUL DES COURANTS DE DEFAUTS

L’IMPEDANCE LIMITANT LE COURANT DE


DEFAUT EST L’IMPEDANCE TOTALE AMONT,
ELLE DEVRA ETRE CALCULEE A UNE TENSION
DE CALCUL UNIQUE.

TOUTES LES IMPEDANCES SONT RAMENEES A


LA TENSION DE CALCUL EN MULTIPLIANT LES
VALEURS D’IMPEDANCES DONNEES SOUS LE
NIVEAU D’UTILISATION PAR (TENSION DE
CALCUL / TENSION D’ UTILISATION)².

26

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Exemples de calcul d’un courant de défaut

Réseau 60 kV Transformateur Câble de 15 km Transformateur


60/20 kV 20/0.4 kV
Neutre des transformateurs
directement à la terre
It = 0.8 Icc

A B C D
Etoile/Etoile à la terre Etoile/Triangle
Pccmax = 1500 MVA Zd = 0.25 + j0.25 Ω/km
Sn = 5 MVA – Ucc = 10 % Sn = 1 MVA – Ucc = 5%
Pccmin = 500 MVA Zo = 0.3 + j0.1 Ω/km
Rtr/Xtr = 0.05s Rtr/Xtr = 0.3s

27

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
DEFAUT EN A

Défauts triphasés Icc : Défauts monophasés It :

Calcul en 20 kV Calcul en 20 kV
Icc maxi (20 kV) = 43.30 kA It maxi (20 kV) = 34.64 kA
Icc mini (20 kV) = 14.43 kA It mini (20 kV) = 11.55 kA

Valeurs ramenées en 60 kV Valeurs ramenées en 60 kV


Icc maxi (60 kV) = 14.43 kA It maxi (60 kV) = 11.54 kA
Icc mini (60 kV) = 4.81 kA Icc mini (60 kV) = 3.85 kA

28

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
DEFAUT EN B

Défauts triphasés Icc : Défauts monophasés It :

Calcul en 20 kV Calcul en 20 kV
Icc maxi (20 kV) = 1.4 kA It maxi (20 kV) = 1.39 kA
Icc mini (20 kV) = 1.31 kA It mini (20 kV) = 1.28 kA

29

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
DEFAUT EN C

Défauts triphasés Icc : Défauts monophasés It :

Calcul en 20 kV Calcul en 20 kV
Icc maxi (20 kV) = 0.92 kA It maxi (20 kV) = 0.96 kA
Icc mini (20 kV) = 0.88 kA It mini (20 kV) = 0.91 kA

30

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
DEFAUT EN D

Défauts triphasés Icc :

Calcul en 20 kV
Icc maxi (20 kV) = 17.72 kA
Icc mini (20 kV) = 0.352 kA

Valeurs ramenées en 0.4 kV


Icc maxi (0.4 kV) = 17.72 kA
Icc mini (0.4 kV) = 17.62 kA

31

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Pourquoi calculer les Icc
(Scc) ?

¾Dimensionnement de l’appareillage
¾Réglage des protections
¾Exploitation
démarrage des moteurs
mise sous tension des bancs de condensateurs
analyses et remèdes des Perturbations

Phénomène
PERTURBATION =
Scc
32

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
„ Lechoix d’un régime de neutre repose sur des
considérations techniques et économiques.

„ Il
doit apporter des réponses aux exigences de
qualité et de sécurité.

„ Ilconditionne pour de nombreuses années, le


fonctionnement du système électrique.

33

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
„Réseaux à neutre isolé
„Réseaux à neutre direct à la terre
„Réseaux à neutre impédant
„Réseaux à neutre compensé

34

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut monophasé

Zn
In 3ico
ico ico ico
Rm
35

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Schéma équivalent d’un
court-circuit monophasé (cas général)

3 Vn
Jdéfaut =
Zd + Zi + Zo + 3Rm
3Vo
Zd Zi Zo

3 Vn
Jd = 3Id =3Ii=3Io
3Rm
36

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre

Zo
F=
Zd

„Cet indicateur conditionne le comportement du


réseau pour un défaut à la terre.

„ Il permet de déterminer les règles de coordination


d'isolement en mode commun à 50Hz.

37

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre et les
courants de défaut à la terre

„Si Zo / Zd < 1
• le courant de défaut à la terre sera le plus important
sur un défaut biphasé à la terre.
– Pour Zh / Zd = 0,2 , Icc Tdéfaut bi= 1,5 Icc T défaut mono

„Si Zo / Zd = 20
•IccT défaut bi = 0,537 IccTdéfaut mono

38

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre et les
courants de défaut à la terre
A
20000
18000 Neutre direct à la terre Neutre impédant
16000
14000 Court-circuit biphasé
12000 avec la terre

10000
8000
Court-circuit
6000 monophasé
4000
2000
0
0 1 3 10 20 50 100
Facteur de mise à la terre
39

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre et
les surtensions dynamiques

40

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre et
les surtensions dynamiques
V
20000
18000
Tensions phases-terre

16000
14000 V3

12000 V2
10000
V1
8000
6000
4000
2000
0
0 0,25 0,5 1 1,5 2 3 4 5 10 40 80 300 600 900
Impédance du neutre (Ω) 41

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le facteur de mise à la terre et
les surtensions dynamiques
„SiZo / Zd < 1 le matériel peut être isolé en mode
commun pour la tension simple
„Si Zo / Zd < 3 la surtension dynamique phase
terre n'excédera pas 1,386Vn. l'isolement du
matériel pourra être réduit.
„Si Zo / Zd > 3 Le matériel devra isolé pour la
tension composée

42

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre isolé

Xco Xco Xco

3ico
ico ico ico
Rm
43

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre isolé
Zo > 1000
Zd

3Vo

Zd Zi
Xco
3 Vn
Jd = 3Id =3Ii=3Io
3Rm

44

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre isolé
Schéma simplifié

3Vo

Xco
3 Vn
Jd = 3Id =3Ii=3Io
3Rm

45

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre isolé
„ Utilisation: Recherche d’une bonne qualité de
service
„ Avantages

• le réseau peut être exploité à défaut maintenu sous


certaines conditions.

• Maîtrise des montées en potentiel des prises de terre


„ Inconvénients Zo / Zd >>3
• Les surtensions dynamiques sont maximales ,

• Ce type de réseau est le siège de défauts doubles


46
• Mauvaise sélectivité du plan de protection

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
„ Utilisation:

• Réseaux rustiques

• Alimentation des charges monophasées


Avantages Zo / Zd < 3
• L’isolement en mode commun peut être réduit.

• Plan de protection trés sélectif pour les défauts francs.


„ Inconvénients

• Courants de défaut très importants et difficile à maîtriser.


47
• Investissements importants dans les circuits de terre.

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
Charges déséquilibrées

48

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
Le déplacement de point neutre
V3
In

A
,7
399

60
V

240
2 51

V
V
382 V

T V1
239 V

16,2 V 245 V
N

V
3 96
7V
A

18
,3
62

49
I2 V2

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
Le déplacement de point neutre
V3-N
250
V1-N

240

230

220

210

200

190 Mesures effectuées le 8 Janvier 1995 au point P


V2-N

180 50
0h

2h

4h

8h

10h

12h

16h

18h

20h

22h
6h

14h

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre

In 3ico
ico ico ico
Rm
51

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
Zo < 3
Zd

Zd Zi

3 Vn Vo Zot

Jd = 3Id =3Ii=3Io
3Rm
52

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre direct à la terre
Schéma simplifié pour Zo << Zd

Zd Zi

3 Vn

Jd = 3Id =3Ii=3Io
3Rm

53

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre impédant
„ Utilisation

• Choisi pour maîtriser les courants de défauts à la terre.


„ Avantages

• Qualité de service moyenne

• Montées en potentiel des prises de terre maîtrisées.


„ Inconvénient 3 < Zo / Zd < 1000
• Les surtensions dynamiques peuvent être importantes.

• Ce type de réseau est le siège de défauts doubles.

• Sélectivité du plan de protection assez complexe 54

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre impédant
3 < Zo < 1000
Zd

Zd Zi

Zot
3 Vn Vo Xco

3Zn
Jd = 3Id =3Ii=3Io
3Rm
55

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le neutre impédant
Schéma simplifié

Zot
3 Vn Vo Xco

3Zn
Jd = 3Id =3Ii=3Io
3Rm

56

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les matériels

R L

Réservé aux réseaux aériens


ou faiblement impédant57

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les matériels

On choisira de préférence un dispositif


présentant une caractéristique résistive telle
que

1
Ro <
2Coω

Co = 3 x capacité par phase du circuit machine-transfo


58

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les transformateurs de point neutre
A B C A B C

N BPN
Zigzag

59

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les transformateurs de point neutre

V1
In

U2
9U2²
R= In.V
1
R

Le générateur homopolaire
60

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
La bobine de
600 Ω

compensation R
x
61

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
ITR / INN

Zn PS

RpNM
62

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
ITN / ITN

Zn PS

RpN RM
63

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
ITS / ITS

Zn PS

Rp RpN RM
64

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
TNR / TNN

RpNM
65

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
TTN / TTN

RpN RM
66

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
TTS / TTS

Rp RN RM
67

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
- / ITR

Zn PS

RN RpM
68

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
- / INS

Zn PS

Rp RN
69

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
- / TTR

RN RpM
70

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 13 - 100 / C 13 – 200
- / TNS

Rp RNM
71

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 15 - 100
IT

Zn PS

RN RM
72

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 15 - 100
TT

RN RM
73

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 15 - 100
TNC

PEN

RN RM
74

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 15 - 100
TNS

PE

RN RM
75

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
C 15 - 100
COMBINAISON TNC TNS
ATTENTION TNC
TNC interdit en aval TNS
d’un TNS

PEN N

PE

RN RM RM RN
76

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Disjoncteur Capteur

Ligne

Déclenchement
RELAIS

Consignes

77

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Rôle

La protection doit, suite à l’apparition d’un défaut,


provoquer la mise hors tension de la plus petite
partie du réseau et le plus rapidement possible

78

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Qualités

SELECTIF
RAPIDE
FIABLE
FIDELE
PRECIS
INDEPENDANT DU RESEAU
STABLE
SENSIBLE
PEU CONSOMMATEUR

79

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Sélectivité

Elle consiste à n’éliminer que la partie du


réseau en défaut
en n’ouvrant que les disjoncteurs les plus
proches du défaut

80

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
La Sélectivité Arrivée
Production

(suite)
Autonome

HT / MT
Ordre de blocage

I> I>

I> I>
I>
I>

I>

I> I>

I> I> I> I>


MT / BT

Autres Process

Utilisation
81

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ TRANSFORMATEUR DE POTENTIEL (TP)

¾ TRANSFORMATEUR DE COURANT (TI)

82

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur inductif de tension (TP)

HT Vp

N1 N2 Vs BT

N2
Vs = Vp *
N1

83

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur capacitif de tension (TCT)

HT

C1
20 kV Amortisseur

√3
C2 Vs
HF
Inductance

84

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
TRANSFORMATEUR INDUCTIF

¾Avantage:

Erreur transitoire faible

¾ Inconvénients:

Impossibilité de couplage de réseau télécom


Coût élevé pour Un > 150 kV

85

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
TRANSFORMATEUR CAPACITIF

¾Avantages:

Permet le couplage de réseaux télécom


Coût raisonnable pour Un > 150 kV

¾ Inconvénient:

Erreur transitoire importante

86

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.P. POUR RELAIS DE PROTECTION

¾ Classe : 3P
¾ Erreur : +/- 3%
¾ Déphasage : +/- 120 minutes

VA nécessaire < Sn < 4 * VA nécessaire

Nota : La résistance de filerie au secondaire d’un TP intervient comme


un facteur d’erreur et non comme un facteur de consommation.
87

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur de courant (TC ou TI)

Ip N1 N2 Is

Ip N1 = Is N2

Ip N1
Is =
N2

88

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. POUR RELAIS DE PROTECTION

¾ Type : 5P ou 10P
¾ Erreur à In: 1% (5P) - 3% (10P)
¾ Erreur à FLP: 5% (5P) ou 10% (10P)
¾ Induction de travail à Ual: 1.8 Tesla

5 P 10
Précision du transfo.: Facteur limite
1% à In – 5% à 10 In de précision
Transfo type
protection
89

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. POUR RELAIS DE PROTECTION

Exemple 1

TC de rapport 500 / 1 A, Rct = 2 Ω, Id = 14.5 kA alimentant un relais


ampèremétrique de résistance Rr = 0.01 Ω, filerie 2 x 50 m en 4².

Résistance de la filerie Rf = 2 x 0.05 x (20/4) = O.5 Ω

Tension limite de précision Ual nécessaire : 72.8 V

Puissance équivalente en classe 5 P 10 : 5.28 VA

Une puissance de 7.5 VA classe 5 P 10 est suffisante.

90

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. POUR RELAIS DE PROTECTION

Exemple 2
On dispose d’un TC 500 / 1 A de 5 VA classe 5 P 15, Rct = 2 Ω.
On veut vérifier que celui-ci est satisfaisant pour l’alimentation de
la protection de l’exemple 1, où la tension limite de précision Ual
nécessaire était de 74 V.

Calcul de la tension limite de précision Ual fournie par le TC :


 Sva  5 
Ual = Ins × Flp ×  + Rct  = 1 × 15 ×  + 2  = 105V
 Ins ²   1 ² 

La tension limite de précision fournie par le TC est supérieure


à la tension limite de précision nécessaire donc le TC 500 / 1 A
de 5 VA classe 5 P 15, Rct = 2 Ω convient.

91

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. POUR PROTECTIONS RAPIDES

COEFFICIENT
COMPOSANTE De
APERIODIQUE SURDIMENSIONNEMENT
K (ou Ktf ou Ktd)
92

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. 5P POUR PROTECTIONS RAPIDES

Sur réseau 50 Hz, Tp = 100 ms, TC de rapport 500 / 1 A, Rct = 2 Ω, Id = 14.5 kA


alimentant une protection rapide de résistance Rr = 0.1 Ω, temps maximum
d’acquisition tal = 25 ms, filerie 2 x 50 m en 4². On prendra un taux d’asymétrie
de 100 %.

¾Valeur de k = 7.9
¾Résistance de la filerie Rf = 2 x 0.05 x (20/4) = O.5 Ω
¾Tension limite de précision Ual nécessaire : 575 V
¾Puissance équivalente en classe 5 P 20 : 26.75 VA

Une puissance de 30 VA classe 5 P 20 est suffisante.

93

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.C. 5P POUR PROTECTIONS RAPIDES

Si l’on souhaite surdimensionner le TC pour qu’il laisse


passer la composante apériodique, il faut :

¾ Utiliser au minimum des TI 5 P 20 – In = 1A

¾ Le TI ne doit alimenter que la protection rapide

¾ A la saturation après le premier de temps


de mesure

¾ Au flux rémanent 94

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur de courant (TC ou TI)
φ
φr Sans entrefer

Coupure 2e défaut T

Avec entrefer

φr T
Tal Td Tr

95

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Court-circuit sans saturation des TC
et sans asymétrie
t=0
U=Û

Icc primaire

Icc secondaire

96

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Court-circuit sans saturation des TC
et avec asymétrie
t=0
U=0

Icc primaire

Icc secondaire

97

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Court-circuit avec saturation des TC
et sans asymétrie
t=0
U=Û

Icc primaire
ø

Icc secondaire

98

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Court-circuit avec saturation des TC
et avec asymétrie
Icc primaire
Ø flux

Icc secondaire

99

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections rapides

REGIME COMPOSANTE
TRANSITOIRE APERIODIQUE

¾ Faculté ou non de la protection à fonctionner sur


des TI partiellement saturés.

¾ Temps d’acquisition des grandeurs.


100

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections rapides

Facteur de dimensionnement

Ktf = Φ e+Φ al = Φ e +1
Φ al Φ al
Paramètres à prendre en considération
¾ Constante de temps Tp
¾ Constante de temps Ts (TPX – TPY – TPZ)
¾ Cosinus de la charge cos β 101

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections rapides

Facteur de dimensionnement

  ω * Tp * Ts
Ktf =  

( ) 
 * e − t / Tp − e t / Ts * t %  + 1
  Tp − Ts  

Nota : Valable pour 1 passage du courant de défaut


t% = taux d’asymétrie
102

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections rapides

Tension secondaire limite d’excitation

Ual = Kssc * Ktd * (Rct + Rb) * Isn

103

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

2 paramètres importants

¾ Stabilité sur défaut extérieur

¾ Fonctionnement sur défaut interne violent

104

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

Protection différentielle à haute impédance


Ia I’a ¾ Stabilité sur défaut extérieur
P1 P2 P2 P1
S1 S1
Rs = 50 Ohm env. pour 5A
Rs Rs = 250 Ohm env. pour 1A

Protection différentielle
longitudinale à haute Raisonnement en tension
impédance 105

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

Protection différentielle à haute impédance


Icc

Tc1 Tc2

Rct1 Rw1 Rw2 Rct2


S1 S1
Rs TC saturé
Icc pas de fem

106

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

Protection différentielle à haute impédance

¾ Fonctionnement sur défaut interne violent

Us > Ur = Icc * (Ins/Inp) * (Rct + Rw)

En général Us = 1.5 Ur

107

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

Protection différentielle à haute impédance

¾ Fonctionnement sur défaut extérieur traversant

Ins  − tal / Tp 
Ual = Itr × × [ 1 − e ω Tp + 1] × (Rct + Rw + Rr )
Inp  

108

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
T.I. alimentant les protections différentielles

Protection différentielle à haute impédance

¾ Fonctionnement sur défaut interne violent

Ual = 1.5 * [I>>] * (Ins/Inp) * (Rct + Rr + Rw)

109

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ MACHINES ASYNCHRONES

¾ MACHINES SYNCHRONES

¾ LES ALTERNATEURS

¾ PROTECTION DES ALTERNATEURS

¾ PROTECTION DES GENERATRICES ASYNCHRONES

110

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Utilisées pour les puissances Sn < 2 MVA

Stator
Vb - Vr = g ≠ 0
Vr
Rotor

B Vb

111

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Diagramme de Blondel

S’emploie pour les machines à pôles saillants

V XdI
δ
ϕ
I RI E = V + RI + j[XdI + (Xd-Xq)If]
112

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Utilisées pour les fortes puissances Sn > 2 MVA

Stator
Vr - Vb = g = 0
Vr
Rotor

B Vb

113

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Diagramme de Behn - Eschenburg

S’emploie pour les machines à pôles lisses

V XdI
δ
ϕ
I RI

E = V + RI + jXdI
114

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Variation du courant de défaut en fonction du temps

Id
E/X’’d

E/X’d

E/Xd

t
115

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
MODE DE FONCTIONNEMENT

Asynchrone:
U 1/R

Moteur
I
1/X

Bloqué Marche à vide

Générateur 116

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
MODE DE FONCTIONNEMENT

Synchrone: X
Moteur Générateur
Sur-excité Sur-excité R
X’d
Sous-excité Sous-excité

Moteur Générateur
Xd
117

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
LE DIAGRAMME DE FONCTIONNEMENT DE LA MACHINES A POLES SAILLLANTS

P Limite
d’échauffement
du stator
P mécanique
Pn M

If
Limite
d’échauffement
Ic du rotor
ϕ
θ
Q
1/Xq 1/Xd O Qn
118

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
LE DIAGRAMME DE FONCTIONNEMENT DE LA MACHINE A POLES LISSES

P Limite
d’échauffement
du stator
P mécanique
M
Pn

If
Limite
d’échauffement
Ic du rotor
ϕ
θ
Q
1/Xd O Qn
119

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Schéma équivalent dans le plan direct

X’’d T’’d

X’d T’d

E Xd
Icc

Xa Ta

Xa = X’’d
120

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le courant de défaut en sortie d’un alternateur est
égal à la somme des courants vus dans le plan
direct

X’’d X’d Xd
0 à 60 ms Après 1 sec
60 à 100 ms
Utilisable pour les calculs Utilisable pour les calculs
simplifiés simplifiés
des protections rapides des protections temporisées

121

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Schéma équivalent dans le plan inverse

Xi

E
Icc

X’’d < Xi < X’d

122

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défauts externes à la machine

¾Surcharge F49 – F26 θ

¾Déséquilibre F46

123

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défauts externes ou internes à la machine

¾Maximum de courant F50/51 – F50/27 – F51V – F21

¾Variations de tension F27 – F59

¾Variations de fréquence F81

¾Surexcitation F24 – F59/81

124

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défauts internes à la machine

¾Masse stator F64S


¾Masse rotor F64R
¾Minimum de courant d’excitation F37E
¾Retour de puissance F32
¾Défaut différentiel F87G – F87N
¾Défaut diodes tournantes F58
¾Défaut machines en parallèle F67 – F67N
125

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26
θ
θm θ = θm (1 – e-t/ι )
θι
θι = 0.632 θm

417 * Gθm
ι=
ι t P

126

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26

F49 I²t 90 à 95% θm

Limite d’échauffement
F26 θ des conducteurs

ACTION : A définir par l’exploitant 127

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26

Dans tous
les cas

Au choix de
L’Exploitant

128

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F51 – F51V (F51/27) – F21

¾Quelle est la valeur du courant de court-circuit ?

¾Quelle est la valeur de la tension aux bornes de la machine ?

Choix de la protection
129

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F51 – F51V (F51/27) – F21

A B C
Xg Xtr Xl

130

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F51
t

Ts = T protection Aval + 0.3s

Ts Is = Icctri / 2
(2 = Coefficient de sécurité)

Is I
131

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F51V (F51/27)

0.8Un U2

U1
0.2Un

Is1 Is2 Is1 Is2


Is = Icctri / 2
(2 = Coefficient de sécurité)
Ts = T protection Aval + 0.3s 132

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F21
t
Zs = 2 * Znominal
(2 = Coefficient de sécurité)
Ts Ts = T protection Aval + 0.3s

Zs Z
133

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F51 – F51V (F51/27) – F21

Dans tous
ARRET
les cas
D’URGENCE

134

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les déséquilibres
F46

¾Coupure d’un conducteur


¾Discordance des pôles
DESEQUILIBRE
du disjoncteur
DE COURANT
¾Charges monophasées
¾Défaut dissymétrique

135

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les déséquilibres
F46
CHAMP STATORIQUE
DESEQUILIBRE COMPOSANTE
DANS LE SENS CONTRAIRE
DE COURANT INVERSE
DU ROTOR

ECHAUFFEMENT
ANORMAL COURANT ROTORIQUE
DES AMORTISSEURS A FREQUENCE DOUBLE
ET DU ROTOR

136

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les déséquilibres
F46

L’équation d’échauffement est de la forme :

I2 ²
θ ≡ *t
In

137

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les déséquilibres
F46

80 à 90 %
1I2s de I2n TC Ts de 5 à 6 s

Ts= Equation à temps inverse


80 à 90 %
2I2s avec une sécurité
de I2n TC de 10 à 20 %

138

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les déséquilibres
F46

Dans tous
les cas

Au choix de
L’Exploitant

139

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre le retour de puissance active
F32

¾Absence de vapeur
LE ROTOR
¾Absence d’eau à la turbine N’EST PLUS
ENTRAINE
¾Manque de carburant

140

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre le retour de puissance active
F32

LE ROTOR N’EST PLUS PUISSANCE ACTIVE


ENTRAINE PRELEVEE AU RESEAU

PROTECTION CONTRE
LE RETOUR DE LA MACHINE FONCTIONNE
PUISSANCE ACTIVE EN MOTEUR

141

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre le retour de puissance active
F32

Relais directionnel à maximum de courant watté

Ps = 50% des pertes

Ts = 1 à 10 s

142

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre le retour de puissance active
F32
Ir
Zone Zone de

de Is = Im cos ϕ Non
Ia

Fonctionnement
Fonctionnement
Im
143

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre le retour de puissance active
F32

Dans tous
ARRET
les cas
D’URGENCE

144

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à minimum de tension
F27

¾Anomalie régulateur U DIMINUTION


DE LA TENSION
EN SORTIE
¾Défaut réseau non éliminé MACHINE

145

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à minimum de tension
F27

F27 Us = 80 à 85 % Un

Ts = 1 à 2 sec

146

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à minimum de tension
F27

Dans tous
ARRET
les cas
D’URGENCE

147

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maximum de tension
F59

¾Anomalie régulateur U
¾Tension réseau élevée AUGMENTATION
¾Survitesse à courant DE LA TENSION
d’excitation constant EN SORTIE
¾Couplage des TP sur MACHINE
défaut masse stator

148

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maximum de tension
F59

F59 Us1 = 115 à 120 % Un


Ts1 = 1 à 2 sec

Us2 = 140 à 150 % Un


Ts2 = 0.1 sec

149

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maximum de tension
F59

Dans tous
ARRET
les cas
D’URGENCE

150

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maxi et mini de fréquence
F81

¾Anomalie régulateur
de vitesse VARIATION
DE
¾Surcharge du réseau FREQUENCE

151

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maxi et mini de fréquence
F81

F81> Fs = Fn + 1.5 à 2 Hz
Ts = 1 à 2 sec

F81< Fs = Fn – 1.5 à 1 Hz
Ts = 1 à 2 sec

152

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection à maxi et mini de fréquence
F81

Dans tous
ARRET
les cas
D’URGENCE

153

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)

L’induction d’une machine est égale à :

β=K E
F
L’induction est proportionnelle à la tension en sortie de machine
et inversement proportionnelle à la fréquence.

D’ou E/F donne une image de l’état


du circuit magnétique de la machine
154

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)
t

K
t= + to
 v 
 − 1φ > P .U .
 Hz 

2.5 s
t2φ
to

0.5 s V/F (P.U.)


1φ> 2φ>

1.1 1.2 155

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)

Dans tous
ARRET
les cas
D’URGENCE

156

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut masse stator

Stator

Xo négligeable devant
It Rt 3Rt = Vn / It

5A < It < 15 A 157

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S

Régime de neutre ?

G G G

I>>> U>>> I faible U faible

158

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S
Transformateur de neutre chargé au secondaire par une résistance.

Xd
R
Zp Zs Rt
159

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S

Résistance de mise à la terre.

Rt It = 10 A

160

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S

Is = 1A pour Vd = 10%

90 ou 95% du bobinage Is = 0.5A pour Vd = 5%


Rt 10 ou 5% de la tension

It
161

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S

Us = 10% pour 90% du bobinage

Us = 5% pour 95% du bobinage

Rt

162

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S

Dans tous
ARRET
les cas
D’URGENCE

163

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S (100%)
Injection de tension BF

R Bf IBf -Ic

164

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S (100%)

Disparition de l’harmonique 3 de tension


Vn3 = 1 à 5% de Vn
Ou
E3
Vn3 = 0.6 à 0.65 E3
Zn Zb On choisit
Vn3 Vs3 = 70 % Vn3 env.
Soit
Vs3 = 0.4 E3
165

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse stator
F64S (100%)

Dans tous
ARRET
les cas
D’URGENCE

166

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F40

¾Défaillance du régulateur
d’excitation
RUPTURE DU
¾Ouverture du circuit
CHAMP
d’excitation
D’EXCITATION
¾Court-circuit du circuit
d’excitation

Nota : Une masse stator ne provoque pas de rupture de champ.


167

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F40

IL NE FAUT PAS CONFONDRE


RUPTURE DE CHAMP
ET
PERTE DE SYNCHRONISME

168

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte de synchronisme
F78

¾Défaillance de l’excitation
¾Apparition brusque
DECROCHAGE
d’une surcharge
DE LA
¾Elimination tardive d’un
MACHINE
défaut (réactif important)

Glissement
PERTE DE SYNCHRONISME du
rotor 169

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F45 F80 F76 F37

Les grandeurs d’excitation sont accessibles (If et Uf)


SHUNT

If < Uf >
If > ROTOR
Uf<

170

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F40
Les grandeurs d’excitation ne sont pas accessibles
X ABC
Lh : Limite haute du cercle
R Lb : Limite basse du cercle
A =CC de l’excitation à 100% charge
Lh
B=CC de l’excitation à 50% charge
C=CC de l’excitation à vide

Lb
171

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F40

Lh = X’du / 2 X’du = Réactance transitoire


longitudinale non saturé

Lb = Lh + Xdu Xdu = Réactance synchrone


longitudinale non saturé

Temporisation d’intégration (Ti) = 0.3 sec env.


Temporisation de fonctionnement Ts = 0.5 à 1 sec.

172

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation (machine à pôles saillants)
F32Q
Le réglage du seuil
Limite de stabilité P
dépendant de la machine
de l’excitation se fera sur
0.9 Qo et α
Ts = 0.5 à 1sec

C Qo L 173

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation (machine à pôles lisses)

F32Q
Le réglage du seuil
P dépendant de la machine
se fera sur
Limite de 0.9 Qo
stabilité de Ts = 0.5 à 1sec
l’excitation

α=90°
Q

C Qo L 174

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection perte d’excitation
F45 F80 F76 F37 F40 F32Q

Dans tous
ARRET
les cas
D’URGENCE

175

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse rotor
F64R
1er défaut 2e défaut
If

+ +
Excitation Rotor Excitation Rotor
- - If

176

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse rotor
F64R
If

+ Rad
Excitation Rotor
-
G U < 24 Vcc

I>

177

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse rotor
F64R

Dans tous
ARRET
les cas
D’URGENCE

178

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
Auxiliaires

G F87G G G
F87B F87

179

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87G
Ia I’a Ia I’a
Stator Stator
P1 P2 P2 P1 P1 P2 P2 P1

Retenue Retenue
S1 S1 S1 S1
I> I>

Protection différentielle Protection différentielle


longitudinale à basse longitudinale à basse
impédance Impédance et à pourcentage
180

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87G
Caractéristique à pourcentage

Id

30% Is = 5 à 10% In TC
Ts = instantané
10%
Is

0.5 2 7 Itr
Itr1 Itr2 Itr3 181

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87G

Ia I’a
Stator
P1 P2 P2 P1
S1 S1
Rs = 50 Ohm env. pour 5A
Rs Rs = 250 Ohm env. pour 1A

Protection différentielle
longitudinale à haute Raisonnement en tension
impédance 182

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87G
Icc

Tc1 Stator Tc2

Rct1 Rw1 Rw2 Rct2


S1 S1
Rs TC saturé
Icc pas de fem

183

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87G

Dans tous
ARRET
les cas
D’URGENCE

184

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N

1er montage. IA + IB + IC
P2 P1
S1

It Stator
P2 Rt Id Haute impédance
P1
185

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N
Ios = 2% In (TC)
2e montage. Ios < 0.2 It
IA + IB + IC TC apairés
P1 P2 P2 P1 Ts = instantané
S2 S1

It Stator
Rt Id Haute impédance

186

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N

Dans tous
ARRET
les cas
D’URGENCE

187

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut diodes tournantes
F58

Stator Rotor
d’excitation d’excitation Rotor Stator
Cont. Alt

Excitation de l’excitatrice Alternateur d’excitation Machine principale

Diodes tournantes

Vers la protection
188

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut diodes tournantes
F58

Rotor

Stator et Rotor
de l’excitatrice

Ouverture d’une diode Valt/Vcc = 25%


Ts = 20 sec env.

Court-circuit d’une diode Valt/Vcc = 60%


Ts = 1 à 3 sec 189

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Défaut diodes tournantes
F58

Dans tous
ARRET
les cas
D’URGENCE

190

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections directionnelles
F67 – F67N

G G
F67 – F67N
Is=20%In TC - Ios=10%It
Sens de TIs = 0.1 s – TIos=0.1 s F67 – F67N
fonctionnement
des protections

191

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections directionnelles
F67 – F67N

G G
F67 – F67N
Is=20%In TC - Ios=10%It
Sens de TIs = 0.1 s – TIos=0.1 s F67 – F67N
fonctionnement
des protections

192

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections directionnelles
F67 – F67N

Dans tous
ARRET
les cas
D’URGENCE

193

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections

¾Masse stator F64S


¾Surintensité F50/51
¾Inversion de phases, succession de phases F47
¾Déséquilibre de courant F46
¾Minimum maximum de tension F27/F59
¾Variation de fréquence F81
¾Protection de découplage (cas EDF)
¾Protection des batteries de condensateurs 194

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Plan de protection

Dans tous
ARRET
les cas
D’URGENCE

195

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ PRESENTATION

¾ TRANSFORMATEUR MONOPHASE

¾ AUTOTRANSFORMATEUR

¾ TRANSFORMATEUR TRIPHASE

¾ PROTECTION DES TRANSFORMATEURS

196

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé

Circuit magnétique

I1 I2

U1 n1 n2 U2

U2 n2 ϕ
η= =
U1 n1 Lignes d’induction
197

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé

Conservation de puissance

P = P1 = U1 I1 cos ϕ1 = P2 = U2 I2 cos ϕ2

Flux d’induction en fonction de I

Ni = (1 / µoµr) * (1/S) ϕ

198

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé
ϕ
Coefficient d’Hopkinson

KH = (ϕ + ϕd) / ϕ
I ϕ1
ϕd
Perméabilité relative
B µr tend vers 1
O 1.8 T

µr constant H ou Iµ
199

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé

Induction

V V
B= = K
NωS ω

200

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé

Schéma équivalent

Lfu Rs Ls
I1 Rp N1 N2 I2

Rf Lµ Charge

201

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Monophasé non saturé

Détermination de l’impédance de fuite

Lfuω I1 = In

A
Ucc

202

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Exemple:

Transformateur 220 / 220 KV - Sn= 60 MVA


In # 157 A

Ucc = 22 KV A I2 = In = 157 A

22
Ucc = 220 = 0.1 = 10 %
203

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Autotransformateur monophasé

ϕ
U2 n2
η= =
U1 n1
N2 N1
P = P1 = U1 I1 cos ϕ1 =
P2 = U2 I2 cos ϕ2
I2 I1

V2
V1 204

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
3 transformateurs monophasés

Up1 Us1

Transformateur
à flux libre
Up2 Us2

Up3 Us3

205

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur triphasé à 3 colonnes
Transformateur à flux forcé
Up2

Up1 Up3

Us1 Us3

Us2 206

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur triphasé à 4 colonnes
Transformateur à flux libre

Up2 Up3

Up1

Us1

Us2 Us3 207

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur triphasé à 5 colonnes
Transformateur à flux libre
Up1 Up2 Up3

Us1 Us2 Us3 208

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Transformateur triphasé

Schéma monophasé équivalent

Lfu Rs Ls
I1 Rp N1 N2 I2

Rf Lµ Charge

209

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les indices horaires
0
11 1
10 2 Couplage du transformateur
YNd11
9 3

8 4 0+10=11
0 6
7 5 4+2=3
6 4 10
8 2 8+6=7

210

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Décomposition vectorielle des courants

JA

IA
ja
-jb -jc
IB
jc
jb
-ja
JC IC JB
211

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Courant d’enclenchement – Inrush current

I
Ie
-t/τe
I(t) = Ie * e

T
Iev # Icc – Par contre Ie varie selon que l’enclenchement
se fasse au primaire ou au secondaire 212

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Courant d’enclenchement – Inrush current

L’harmonique de rang 2
Enclenchement de transformateur
au passage à zéro de la tension
Sans flux rémanent

1/4 de période

213

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
L’harmonique de rang 3

I1

I2

I3

214

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
D’ou l’impédance directe du transformateur:
U²n (KV)
Zdtr = Sn (MVA) * Ucc

Schéma équivalent:
E Zs Zdtr
Icc

Sans tenir compte de Zs avec Ucc = 10 %, en


appliquant Un au primaire, et le secondaire en
court-circuit on obtient:
In
Icc = Ucc = 1570 A
215

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Détermination de la tension de court-circuit
d’un transformateur

A partir du schéma direct:


Ucc = Tension à appliquer au primaire (en % de Un)
pour obtenir au secondaire en court-circuit une
intensité égale au courant nominal In.

Ucc ? A I = In

216

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Exemple:

Transformateur 220 / 220 KV - Sn= 60 MVA


In # 157 A

Ucc = 22 KV A I = In = 157 A

22
Ucc = 220 = 0.1 = 10 %
217

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Impédance inverse d’un transformateur:

Zitr = Zdtr

218

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Impédance homopolaire d’un transformateur:

¾Dépend du couplage du transformateur

¾Dépend de la réalisation (Nbr de colonnes, flux


libre, flux forcé).

¾Dépend du réseau (rebouclage des défauts à la


terre)

¾Impédance homopolaire non bidirectionnelle


(Zops différente de Zosp)
219

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Principaux couplages

YNd

Zotr = Zdtr Zotr = ∞

220

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
YNyn

Zotr = ∞ (flux libre)


Réseau
Zotr = 10 Zdtr (flux forcé)

221

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
YNyn

Zotr = Zdtr Réseau

222

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections

¾Surcharge thermique F49T - F26


¾Surintensité F50/51 – F50N/51N
¾Différentielle F87T
¾Différentielle homopolaire F87N
¾Surexcitation F24
¾Directionnelle F67 – F67N
¾Masse cuve F51C
223

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Schéma protection

F50/51 – F51N – F49T


F24

F26
F87T F51C

F51N
F67
F87REF 224

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
F87REF 225

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26
θ
θm θ = θm (1 – e-t/ι )
θι
θι = 0.632 θm

417 * Gθm
ι=
ι t P

226

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26

F49 I²t 90 à 95% θm

Limite d’échauffement
F26 θ des conducteurs

227

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surcharges thermiques
F49 –F26

Dans tous
les cas

Au choix de
L’Exploitant

228

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
T protection aval
F87REF 229

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N
F50
Is > 2*Ie
Is>2*Icc aval
2 = coefficient de sécurité
Ts = instantané

F87T

Icc aval

T protection aval 230

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N
F51
Is = Icc aval /2
Ts = Tprotection aval + 0.3s

F87T

Icc aval

T protection aval 231

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N
F51N
Ios = 10% In TC
Ts = 0.1 s
Icco

F87T

T protection aval 232

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N

F51N
Ios = 10 à 20 % Icco
Ts = Tprotection aval + 0.3 s

F87T

Icco

T protection aval 233

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection contre les surintensités
F50/51 – F50N/51N

Dans tous
ARRET
les cas
D’URGENCE

234

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87T

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
F87REF 235

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87T
Caractéristique à pourcentage

Id

50%
Is = 20% In Tc 20%
(30 à 40 % avec régleur)
Ts = instantané
0.5 2.5 12 Itr
Itr1 Itr2 Itr3 236

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87T
Principe de fonctionnement
Déclenchement
Amont Id
= Id > Is
Aval Amont - Aval
IdH2 &
IdH2
=
< H2
Amont H2 – Aval H2
IdH5
IdH5
=
< H5 237
Amont H5 – Aval H5

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle
F87T

Dans tous
ARRET
les cas
D’URGENCE

238

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N – F87REF

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
F87REF 239

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N – F87REF

IA + IB + IC
P2 P1
S1

It
P2 Rt Id Haute impédance
P1
240

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N – F87REF

Ia I’a
P1 P2 P2 P1
S1 S1
Rs = 50 Ohm env. pour 5A
Rs Rs = 250 Ohm env. pour 1A

Protection différentielle
longitudinale à haute Raisonnement en tension
impédance 241

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N – F87REF
Icc

Tc1 Tc2

Rct1 Rw1 Rw2 Rct2


S1 S1
Rs TC saturé
Icc pas de fem

242

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection différentielle homopolaire
F87N – F87REF

Dans tous
ARRET
les cas
D’URGENCE

243

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
F87REF 244

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)

L’induction d’une machine est égale à :

B=K E
F
L’induction est proportionnelle à la tension en sortie de machine
et inversement proportionnelle à la fréquence.

D’ou E/F donne une image de l’état


du circuit magnétique de la machine
245

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)
t
K
t= + to
 v 
 − 1φ > P .U .
 Hz 

2.5 s
Ts2φ
To
0.5 s V/F (P.U.)
1φ> 2φ>

1.16 1.25 246

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de surexcitation
F24 (59/81)

Dans tous
ARRET
les cas
D’URGENCE

247

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection directionnelle
F67 – F67N

D6
F51/51N F51/51N
D1 D2 G.H.
Défaut 2

Défaut 1
D3 D4
F67/67N F67/67N
248
D5 T protection aval

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection directionnelle
F67 – F67N
F51 D6
Is=160%In
Ts= Tprotection F51N
aval + 0.3s Ios = 10%It
D1 Ts = 0.1s
D2 G.H.

T1 T2

Défaut 1
F67N
F67 D4 Ios=10%It
Is=20%In D3
Φ= 90°
Φ=90° Ts=0.1s
Ts=0.1s
249
D5 T protection aval

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection directionnelle
F67 – F67N

Dans tous
ARRET
les cas
D’URGENCE

250

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse cuve
F51C

F50/51 – F49T
F24

F26
F87T F51C

F51N
F67
F87REF 251

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection masse cuve
F51C

F51C
Ios primaire =100 A
Ts=0.1s

252

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection de masse cuve
F51C

Dans tous
ARRET
les cas
D’URGENCE

253

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Régulation de tension (90)

Tr -3 -2 -1 m +1+2 +3

Régleur en charge
TP - +
Régulateur
254

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Régulation de tension (90)

Fonctions associées à l’absence de défaut sur le réseau

¾ Minimum de U triphasée – (F27)

¾ Maximum de U triphasée – (F59)

¾ Maximum de I triphasé – (F51)

¾ Minimum de I triphasé – (F37)


255

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ PRESENTATION

¾ LES DEMARRAGES

¾ LE MOTEUR EN FONCTIONNEMENT

¾ PROTECTION DES MOTEURS

256

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les données constructeurs
¾ Puissance nominale du moteur
¾ Tension d’utilisation
¾ Type de service
¾ Classe des isolants
¾ Surcharge permanente admissible
¾ Courant nominal
¾ Cosinus phi
¾ Rendement nominal
¾ Courant de démarrage
¾ Temps de démarrage
¾ Temps max rotor bloqué
¾ Nombre de démarrages à froid et à chaud
¾ Temps entre deux démarrages successifs à froid et à chaud
¾ Constante de temps thermique à l’échauffement et au refroidissement
¾ Temps max admissible en fonctionnement déséquilibré
257

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Les données du réseau d’alimentation

¾ Puissance de court-circuit maximale entre phases

¾ Puissance de court-circuit minimale entre phases

¾ Puissance de court-circuit maximale monophasée

¾ Puissance de court-circuit minimale monophasée

¾ Taux de déséquilibre en tension garanti

258

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Classement des moteurs

¾ Selon le niveau de tension de l’installation

¾ Selon la nature du moteur

259

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Classement des moteurs

U < 400 V

¾ Sn théorique < 132 KW

¾ Sn pratique < 150 KW

MOTEURS ASYNCHRONES

260

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Classement des moteurs

400 V < U < 20 KV

¾ 100 KW < Sn théorique < 2 MW

¾ Sn pratique < 3.5 MW

MOTEURS ASYNCHRONES

261

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Classement des moteurs

400 V < U < 20 KV

¾ Sn théorique > 1.5 MW

¾ Sn pratique < 2 MW

MOTEURS SYNCHRONES

262

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Utilisation des moteurs

Les moteurs asynchrones à cage

¾ Service continu ou nombre de démarrages réduit


¾ Bonne adaptation aux atmosphères explosives
¾ Entraînement des machines à couples résistants paraboliques
¾ Pompes centrifugeuses
¾ Compresseurs
¾ Machines outils
¾ Ventilateurs
¾ Groupes convertisseurs
¾ Génératrices asynchrones
263

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Utilisation des moteurs

Les moteurs asynchrones à rotor bobiné

¾ Démarrage à forte inertie


¾ Ventilateurs à grande inertie
¾ Démarrages fréquents
¾ Engins de levage
¾ Couple de décollage élevé
¾ Broyeurs
¾ Malaxeurs
¾ Transporteurs
¾ Génératrices asynchrones
264

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Utilisation des moteurs

Les moteurs synchrones

¾ Nécessité d’une vitesse constante


¾ Compensateurs synchrones
¾ Unités importantes à vitesse lente
¾ Ventilateurs d’agglomération
¾ Compresseurs
¾ Soufflantes de hauts fourneaux
¾ Génératrices synchrones

265

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage direct

¾ Avantages:

Solution simple

¾ Inconvénients:

Fort courant d’appel

266

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage indirect

¾ Avantages:
Limitation du courant d’appel
Applicable à tous les moteurs

¾ Inconvénients:
Limitation du couple moteur
Sortie des 6 bornes du bobinage
Couplage de fonctionnement en triangle
Organe de commutation étoile triangle
267

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage à intensité contrôlée : Par réactances statoriques

¾ Avantages:

Ne consomme pas d’énergie active

¾ Inconvénients:

Limitation du couple moteur


Nécessite des dispositifs de puissance

268

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage à intensité contrôlée : Par résistances statoriques

¾ Avantages:

Solution simple

¾ Inconvénients:

Limitation du couple moteur


Nécessite des dispositifs de puissance

269

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage à intensité contrôlée : Par autotransformateur

¾ Avantages:
Ne consomme pas d’énergie active
Courant d’appel couple nominal en
adéquation

¾ Inconvénients:
Limitation du couple moteur
Nécessite des dispositifs de puissance

270

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage

Démarrage à intensité contrôlée : Par résistances rotoriques

¾ Avantages:
Réduction du courant d’appel
Augmentation du couple moteur
Adaptation couple moteur / résistant

¾ Inconvénients:
Limitation du couple moteur
Nécessite des dispositifs de puissance

271

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Types de démarrage
Démarrage à intensité contrôlée : Par variateur de vitesse
¾ Gradateur:
Action sur tension statorique
¾ Cascade hyposynchrone
Action sur courant rotorique
¾ Cycloconvertisseur
Action sur tension et fréquence statorique
¾ Redresseur-onduleur autonome
Action sur tension et fréquence statorique
¾Redresseur-onduleur autopiloté
Action sur tension et fréquence statorique
(moteur synchrone) 272

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le démarrage
Schéma équivalent

Xs Rs Xr Rr(st)/gl

Un Im Zm

Is

Un
Is =
( Xs + Xr )2 + (Rs + Rr (st ) / gl )2
273

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Le démarrage
Mise sous tension


N
dN
Tdém( s ) = J * *∫
60 o Cm − Cr

dU Sdém
=
Un Sam + Sdém

Pn 1 Idém
Sdém = * *
ηn cos ϕn In
274

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement
Echauffement
Φc

Rt Rf Schéma
Un Cu θ Cu Cf θ équivalent

Φc Rd
Un Cu+Cf θ Cu θ

275

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement
Echauffement
θ
θn
θι

ι t
-t/ι -t/ι
θ = θn (1 – e ) (I/In)² (1 – e )
2

θ = θ n * (1 − e )
− t / Te  I 
* 
 In  276

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement

Refroidissement
θ
θn

θι

ι t
-t/ι -t/ι
θ = θn* e (I/In)² *e

θ = θi * e − t / Tr *( I/In)² 277

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement

Echauffement dû à la composante inverse

Fréquence du courant rotorique (Fr) :

Fr = Fn * (2 – gl)

Glissement (gl):

gl=glissement=1−ωs−ωr
ωs

Moteur asynchrone: gl = 0.98


Moteur synchrone: gl = 0
278

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement

Echauffement dû à la composante inverse

Moteur asynchrone: Fr = 99 Hz

Moteur synchrone: Fr = 100 Hz

PERTES PAR EFFET JOULE IMPORTANTES

279

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
En fonctionnement

Echauffement dû à la composante inverse

« Courant thermique »

Ie = Id ² + kIi ²

Coefficient de « survalorisation »

2
 Zi 
k =   / 10
 Zn 
280

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Moteur asynchrone

Participation du moteur au courant de défaut triphasé


¾ Valeur crête de Icc à 10 ms

Icrête =
In * 2
Zdroblo
(
* e −0.01 / Ta + e −0.01 / Tp )
¾ Valeur apériodique de Icc à 60 ms
In * 2
Iapé = * e −0.06 / Ta
Zdroblo
¾ Valeur efficace symétrique de Icc à 60 ms
In
Ieff = * e −0.06 / Tp
Zdroblo 281

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Moteur synchrone

Participation du moteur au courant de défaut triphasé


¾ Valeur crête de Icc à 10 ms

 1 1  −0.01 / T ''d  1 1  −0.01 / T 'd  1  −0.01 / Ta 1 


Icrête = In * 2 *   − *e + − *e + *e + 
 X ''d X 'd   X ' d Xs   X ''d  Xs 

¾ Valeur apériodique de Icc à 60 ms


In * 2 −0.06 / Ta
Iapé = *e
X ''d
¾ Valeur efficace symétrique de Icc à 60 ms
 1 1  −0.06 / T ''d  1 1  −0.06 / T 'd  1  
Ieff = In *   − *e + − *e +   
 X ''d X 'd   X ' d Xs   Xs   282

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

F49 – F46 – F50/51


F64 – F48 – F51LR
F27 – F27d – F59
F66 – F37
F81

F23

283

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection thermique
t
F49
Ie = Id ² + kIi ²

t = Te * Logn
n² − s ²

Ib I

F23
Sondes Pt, CU, Ni
ou varistances
Mesure directe
de la température 284

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les déséquilibres de courant

F46
Iis = 0.2 In F47
Ts = 2s Inversion de phases

285

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les courts-circuits

F50/51
Is = 1.5 à 1.7 Idém
Ts = 0.1 s
F87M
Is = 10 à 20% In TC
ts = instantanée

286

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les défauts d’isolement

F50N/51N – F64
Ios = 10% In TC
Ts = 0.1 s

287

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les défauts d’isolement

It
F50N/51N – F64
Ios = 10 % In TC
Ios < 50% It
Ts = 0.1 s

288

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Protection contre les défauts d’isolement

Iods = ? 3*Vn*Cos*ω
Iodd=3*Vn*Cod*ω
F51N - F67N
Si Ios>2Iodd alors F51N ou F67N
Si Ios<2Iodd alors F67N impératif Iods
Ios <0.5 Iodsmini Iodd
Ts = 0.1 s

Cos
Cod

Iodsmini = (courant capacitif minimum du minimum de moteur pouvant rester en 289


service) – (courant capacitif du départ supposé en défaut)

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Protection contre les défauts d’isolement
T amont
F50N/51N
Ios = 5 % In TC
Ios < 10 à 20% It
Ts = Tamont + 0.3 s

F64
Ios = 10 à 20% It
Ts = instantané
It
290

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les démarrages trop long

F48
Is = 2 In
ts = 1.3 * Tdém

291

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les rotors bloqués : Troblo > Tdém

F51LR
Tdém < Ts < Troblo

292

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs

Protection contre les rotors bloqués : Troblo < Tdém

¾Fonction tachymétrique

¾Contrôle logique

293

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Fonction tachymétrique

F51 F49
Is = 2In Is = 2In
Ts = 1.3*Tdem Constante temps Te

& &

Non Non
rotation rotation
294

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Contrôle logique

F51 + F27 F21


Zs = Un / 2 Is
F51 Ts = 0.5 s
Is = 2 In
Ts = 0.5 s

F27
Us = 0.8 Un
Ts = 0.5 s
295

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Protection contre les marches à vide

F37
Is = (Ivide + Imini)/2 F37
Ts = 5 à 10sec Ps< = 0.25 Sn
cos ϕ = 0.5
Ts = 5 à 10sec

296

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Protections complémentaires pour les moteurs de forte puissance

F27-1: Us = 0.75 à 0.8 Un F81U: Fs = 48 à 48.5 Hz


Ts = 3s ou plus Ts = 4s ou plus
F27-2: Us = 0.2 à 0.25 Un F81O: Fs = 51.5 à 52 Hz
Ts = 0.1 s Ts = 4s
F27d: Us = 0.75 à 0.8 Un
Ts = 2s ou plus
F59d: Us = 1.1 à 1.15 Un
Ts = 3s ou plus

297

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des moteurs
Protections supplémentaires pour les moteurs synchrones

F78: Etude particulière


F40: 0.5 X’d et 1.2 Xs
Ts= env 2 s
90% -> Q (30% Sn)
Ts = env 2 s
F32: P = 1% à 5% Pn
Ts = 0.15 s
F64R: Is = 1 à 3 kOhm
Ts = 4s
F55: Cos ϕ = 0.8 (AR)
Cos ϕ = 0.95 (AV)
Ts = 2 s
298

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
¾ PRESENTATION

¾ PROTECTION DES AUXILIAIRES

299

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Définition

Les auxiliaires de centrale sont tous


les périphériques nécessaires
au bon fonctionnement
de l’alternateur et de son transformateur

C’EST A DIRE…

300

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________

Le matériel nécessaire au démarrage de la centrale:


Le transformateur de démarrage
Le groupe de démarrage

Le matériel nécessaire au fonctionnement de la centrale:


Le transformateur de soutirage
Le transformateur d’excitation

301

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Ces auxiliaires devront permettre l’alimentation de:

¾ L’éclairage

¾ L’air comprimé

¾ La ventilation

¾ Moteurs

¾ Redresseurs

¾ Etc…
302

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des transformateurs de démarrage et
de soutirage

F50/51
F50N/51N
F49 F95 F26

HTA / BT

303

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection du groupe de démarrage
Inférieur ou égal à 3 MVA

Protections nécessaires Protections conseillées


F64S – F50/51 F87G – F46
F59 – F32 F26

304

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection du groupe de démarrage
de 3 MVA à 10 MVA

G
Protections nécessaires
F87G – F46 – F26 Protections conseillées
F64S – F50/51 F87GT – F50/51V
F59 – F32 F21 – F40 – F 64R
F81

305

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Schéma type
Auxiliaires
Diésel

Transformateur
auxiliaire

Réseau

Transformateur
de démarrage

Transformateur
Transformateur
de soutirage
élévateur

Alternateur Evacuation

Transformateur
d’excitation
Autres générateurs
306

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons

Liaisons en antenne

F51 – F51N

Départs
307

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons
Liaisons en boucle ouverte
D1: facultatif – Ouvert ou fermé
Si D2 ouvert, alors D3 fermé
D1 Si D3 ouvert, alors D2 fermé

D2 D3
F51 – F51N F51 – F51N

D4

308

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons
Liaisons en boucle fermée

D1: facultatif – Ouvert ou fermé


D2, D4, D3, D5 fermés
D1

D2 D3
D4 D5

D6

309

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons
Protections directionnelles

D1

D2 D3
F51 – F51N F51 – F51N

F67 – F67N F67 – F67N


D4 D5

D6

310

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons

Protections directionnelles de terre


Réseau à neutre isolé

Départs sains

3Ico

Départs en défaut

311

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons
Protections différentielles

D1

D2 D3
F51 – F51N F87 F87 F51 – F51N
Fils pilotes Fils pilotes

F51 – F51N F87 F87 F51 – F51N


D4 D5
D6
312

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections différentielles
Montage à somme dissymétrique
A

nCt

nBt Grandeur à comparer


nAt
313

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections différentielles
Fils pilotes – Montage à circulation de courant

Antagoniste Antagoniste

Moteur Moteur

TC TC
Sommateur Sommateur

314

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protections différentielles
Fils pilotes – Equilibre de tension

Moteur Moteur

R Antagoniste Antagoniste R

TC TC
Sommateur Sommateur

315

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons

Protections ampèremétriques
Principe de sélectivité à temps constant

D3 D2 D1

316

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons

Protections ampèremétriques
Principe de sélectivité à temps dépendant
I

Icc3
Icc2
Icc1
T
t3 t2 t1 317

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________
Protection des liaisons
Protections ampèremétriques
Principe de sélectivité à temps dépendant
I

Icc3 = 2 = 1

T
t3 t2 t1 318

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________

You might also like