DISEÑO GEOMETRICO DE BADEN

TIPO 1 L= 10 M
BADEN TRIANGULAR

L1 L2

S= 5% S= 5%
H

𝐶𝑎𝑢𝑑𝑎𝑙 𝑑𝑒 𝑑𝑖𝑠𝑒ñ𝑜 = 1.96 𝑚3 /𝑠𝑒𝑔


𝑪𝒂𝒍𝒄𝒖𝒍𝒐𝒔:
𝐿1 = 5.00𝑚
𝐿2 = 5.00 𝑚
𝐻 = 0.25 𝑚
𝑆𝐿 = 0.050 𝑚/𝑚
𝑍 = 20.00
𝑛 = 0.023 ( 𝑚𝑎𝑚𝑝𝑜𝑠𝑡𝑒𝑟𝑖𝑎 𝑑𝑒 𝑝𝑖𝑒𝑑𝑟𝑎 )

𝑬𝒎𝒑𝒍𝒆𝒂𝒏𝒅𝒐 𝒍𝒂 𝒇𝒐𝒓𝒎𝒖𝒍𝒂 𝒅𝒆 𝑴𝒂𝒏𝒏𝒊𝒏𝒈:


2⁄ 1⁄
𝐴∗𝑅 3 ∗𝑆 2
𝑄=
𝑛
𝐴 = 1.250 𝑚2
𝑃 = 10.012𝑚
𝑅 = 0.125 𝑚

𝑄𝐵𝑎𝑑𝑒𝑛 = 3.04 𝑚3/𝑠𝑒𝑔

CUADRO Nº 17
CAUDAL PENDIENTE PENDIENTE
CAUDAL FLECHA
Nº TIPO UBICACIÓN DISEÑO LONGITUDINAL TRANSVERSAL CHEQUEO
BADEN H (m)
(m3/seg) % %

TRAMO I : AGUACANTABA – ANAYUNGA L= 14.20KM

1 1 03+429 1.96 3.04 0.25 5.00% 0.05 CONFORME


2 1 11+750 1.71 3.04 0.25 5.00% 0.05 CONFORME
3 1 11+845 0.36 3.04 0.25 5.00% 0.05 CONFORME
4 1 12+365 2.11 3.04 0.25 5.00% 0.05 CONFORME
TRAMO II : DV KM 06+865 – PAN DE AZUCAR L=02.18KM
5 1 01+825 0.86 3.04 0.25 5.00% 0.05 CONFORME