You are on page 1of 1

Malfunction Code Malfunction Name Detection Timing

C0000 Main Motor Failure


• The Transport Motor Lock signal remains set to H
for a set period of time while the Transport Motor is turning.

C0010 Imaging Unit Motor Failure


• The Imaging Unit Motor Lock signal remains set to H for a set
period of time while the Imaging Unit Motor is turning.
• The Imaging Unit Motor Lock signal remains set to
L for a set period of time while the Imaging Unit
Motor remains stopped.

C0044 EDH Fan Motor Failure


• Refer to the Service Manual for the relevant option.

C0045 Cooling Fan Failure


• The Cooling Fan Motor Lock signal remains set to
H for a set period of time while the Cooling Fan
Motor is turning.
• The Cooling Fan Motor Lock signal remains set to
L for a set period of time while the Cooling Fan
Motor remains stopped.

C004E Power Unit Cooling Fan Failure


• The Power Unit Cooling Fan Motor Lock signal
remains set to H for a set period of time while the
Power Unit Cooling Fan Motor is turning.
• The Power Unit Cooling Fan Motor Lock signal
remains set to L for a set period of time while the
Power Unit Cooling Fan Motor remains stopped.

C004F IU Cooling Fan Failure


• The I/U Cooling Fan Motor Lock signal remains set
to H for a set period of time while the I/U Cooling Fan Motor is turning.
• The I/U Cooling Fan Motor Lock signal remains set to L for
a set period of time while the I/U Cooling Fan Motor remains stopped.

C0214 Abnormal Image Transfer Voltage


• The image transfer voltage exceeds 100 V for the
set period of time while the Imaging Unit Motor
remains stopped.

C0500 Fusing Warm-Up Failure (Main)


• The Fusing Roller Thermistor does not detect the
required temperature within 30 sec. after a warmcycle has begun;
therefore, the copier does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not
reach the required level even after the set period of
time has elapsed during a warm-up cycle.

C0501 Fusing Warm-Up Failure(Sub)


• The Fusing Roller Sub Thermistor does not detect
the required temperature within 30 sec. after a warm-up cycle has
begun;
therefore, the copier does not complete the warm-up cycle.
• The temperature of the Fusing Rollers does not reach the required level
even after the set period of time has elapsed during a warm-up cycle.