You are on page 1of 7

Wind Load Analysis

R HE + R E 8.5+6
Mean Roof Height = = = 7.25 m
2 2

2.5
tan θ =
4
θ = 32.005o

 P.1-6; Table 103-1

Occupancy Category: IV – Standard Occupancy

 P.2-38; Figure 207A.5-1A to 5-10

V = 250 km/hr
V = 69.44 m/s

 P.2-42

Kd = 0.85

 P.2-47

Kzt = 1

 P.2-67; Section 207B.32

qz = 0.613 Kz Kzt Kd V2
qz = 0.613 (Kz) (1) (0.85) (69.44)2
qz = 2512.4581 Kz
 P.2-68; Section 207B4.1

P = q GCp – qi GCpi; Pa (N/m2)

 P.2-55; Section 207A.9.1

G = 0.85

Use qi = qh

Use q = 2512.4581 Kz

 P.2-42; Section 207A.7.3

Exposure Category = B

 qi = 2512.4581 Kz

 P.2-68; Table 207B.3-1

Kz = use hmean

h Kz
6 0.62
7.25 Kz
7.5 0.66

6−7.25 0.62−K z
=
6−7.5 0.62−0.66

Kz = 0.653

qi = 2512.4581 Kz
qi = 2512.4581 (0.653)
qi = 1640.635 Pa

 P = q (0.85) (Cp) – (1640.635) ( ± 0.18 )


P = 0.85 q Cp ± 295.314

 Solving P for each face of the building


i. Windward Roof; use q = qh = qi

(Cp is in P.2-74)

@ θ = 32.005o

h 7.25
= = 0.906
L 8

h/L Cp
30o 32.005o 35o
0.5 -0.2 X1 -0.2
0.2 X2 0.3
0.906 A1 Cp1 B1
A2 Cp2 B2
≥10 -0.3 Y1 -0.2
0.2 Y2 0.2

(For 30o – Vertical Direction)

0.5−0.906 −0.2− A 1
= ≈ A1 = -0.204
0.5−10 −0.2−(−0.3)

0.5−0.906 0.2− A 2
= ≈ A2 = 0.2
0.5−10 0.2−0.2

(For 35o – Vertical Direction)

0.5−0.906 −0.2−B 1
= ≈ B1 = -0.2
0.5−10 −0.2−(−0.2)

0.5−0.906 0.3−B 2
= ≈ B2 = 0.279
0.5−10 0.3−0.2

(For 0.5 – Horizontal Direction)


0 o
30 −32.005 −0.2−X 1
0 o = ≈ X1 = -0.2
30 −35 −0.2−(−0.2)

30 0−32.005o 0.2−X 2
= ≈ X2 = 0.2401
30 0−35o 0.2−0.3
(For ≥10 – Horizontal Direction)

30 0−32.005o −0.3−Y 1
= ≈ Y1 = -0.2599
30 0−35o −0.3−(−0.2)

30 0−32.005o 0.2−Y 2
= ≈ Y2 = 0.2
0
30 −35
o
0.2−0.2

(For 0.906 – Horizontal Direction)

30 0−32.005o −0.204−Cp 1
0 o = ≈ Cp1 = -0.202
30 −35 −0.204−(−0.2)

0 o
30 −32.005 0.2−Cp2
= ≈ Cp2 = 0.232
0
30 −35
o
0.2−0.279

 Using +GCpi; Using Cp = -0.202

P = 0.85 q Cp + 295.314
P = 0.85 (1640.635) (-0.202) +¿ 295.314
P = 13.617 Pa

 Using -GCpi; Using Cp = -0.202

P = 0.85 q Cp - 295.314
P = 0.85 (1640.635) (-0.202) – 295.314
P = -577.011 Pa

 Using +GCpi; Using Cp = 0.232

P = 0.85 q Cp + 295.314
P = 0.85 (1640.635) (0.232) +¿ 295.314
P = 618.847 Pa = 2.919 kN/m

 Using -GCpi; Using Cp = 0.232

P = 0.85 q Cp - 295.314
P = 0.85 (1640.635) (0.232) – 295.314
P = 28.219 Pa

ii. Leeward Roof; use q = qh = qi

h/L Cp
≥20o
0.5 -0.6
0.906 Cp
≥10 -0.6

0.5−0.906 −0.6−Cp
= ≈ Cp = -0.6
0.5−10 −0.6−(−0.6)

 Using +GCpi; Using Cp = -0.6

P = 0.85 q Cp + 295.314
P = 0.85 (1640.635) (-0.6) +¿ 295.314
P = -541.41 Pa = -2.554 kN/m

 Using -GCpi; Using Cp = -0.6

P = 0.85 q Cp – 295.314
P = 0.85 (1640.635) (-0.6) – 295.314
P = -1132.038 Pa

iii. Windward Wall

Cp is in P.2-74
Cp = 0.8

L=8m
B=7m L/B = 1.143

Use q = qz = 2512.4581 Kz

(Use all values)


hmean = 7.25 m

(Use only up to “6”)

 Using +GCpi; Using Kz = 0.57 for h = 0 – 4.5

P = 0.85 q Cp + 295.314
P = 0.85 (2512.4581) (0.57) (0.8) + 295.314
P = 1269.143 Pa = 1.269 kN/m

 Using +GCpi; Using Kz = 0.62 for h = 6


P = 0.85 q Cp + 295.314
P = 0.85 (2512.4581) (0.62) (0.8) + 295.314
P = 1354.566 Pa = 8.127 kN/m

 Using -GCpi; Using Kz = 0.57 for h = 0 – 4.5

P = 0.85 q Cp – 295.314
P = 0.85 (2512.4581) (0.57) (0.8) – 295.314
P = 678.515 Pa

 Using -GCpi; Using Kz = 0.62 for h = 6

P = 0.85 q Cp – 295.314
P = 0.85 (2512.4581) (0.62) (0.8) – 295.314
P = 763.938 Pa

iv. Leeward Wall

Cp is in P.2-74

L=8m
B=7m L/B = 1.143

L/B Cp
0-1 -0.5
1.143 Cp
2 -0.3

1−1.143 −0.5−Cp
= ≈ Cp = -0.4714
1−2 −0.5−(−0.3)

Use q = qh = qi
qi = 1640.635 Pa

 Using +GCpi

P = 0.85 q Cp + 295.314
P = 0.85 (1640.635) (-0.4714) + 295.314
P = -362.072 Pa

 Using -GCpi

P = 0.85 q Cp – 295.314
P = 0.85 (1640.635) (-0.4714) – 295.314
P = -952.700 Pa

You might also like