Professional Documents
Culture Documents
high-performance systems
delivering superior data quality
and sampling flexibility
the new LAMBDA Series introduces
intelligent modules and accessories
designed to enhance flexibility,
productivity and convenience
in your lab
Dear Analytical Scientist:
PerkinElmer’s LAMBDA™ Series UV/Vis/NIR and UV/Vis spectrophotometers have consistently offered
best-in-class accuracy, precision and reproducibility to scientists for nearly 50 years. For sampling
flexibility and superior data quality, our instruments have become the standard in thousands
of laboratories, in multiple industries worldwide. Building on this tradition of excellence,
the new high-performance, innovative LAMBDA 950/850/650 range confirms our leadership
in UV/Vis/NIR and UV/Vis spectroscopy.
LAMBDA Series:
Designed by scientists – for scientists. next-generation technology
We designed the LAMBDA 950/850/650 Series knowing the complex requirements of today’s
laboratories. When we queried our customers and industry experts, users overwhelmingly requested
greater flexibility and easier-to-use and more functional accessories, along with the ability to produce
addressing the demands of today’s labs
results more quickly, and advanced software routines. As a result, the new LAMBDA Series offers
an unmatched range of snap-in sampling modules, as well as newly engineered workflow software, UV-Vis-NIR
ensuring increased productivity. We’ve also redesigned the LAMBDA Series for the highest PerkinElmer introduces a range of state-of-the-art LAMBDA 950
spectroscopic performance. PerkinElmer is proud to introduce several new advanced features and spectrophotometers featuring innovative, 175 nm 3,300 nm
accessories, including the industry’s first fully automated Universal Reflectance Accessory (URA). quick-change, intelligent accessories, along with an
Our URA, which completely redefines and simplifies variable angle absolute reflectance analysis, • Highest performance UV/Vis/NIR system
expanded range of new options, tools and software.
reduces set-up time and increases throughput for a broad range of tough measurements. • Wavelength range: 175 nm – 3,300 nm
Our new systems minimize non-productive time
Everything you need, we thought of. spent on set-up and alignment, and offer something • UV/Vis resolution: 0.05 nm – 5.00 nm
that is available nowhere else – PerkinElmer’s NIR resolution: 0.20 nm – 20.00 nm
No matter what your industry – from optical coatings to life sciences to glass – and whether you need
to analyze optics, flat panel displays or semiconductors – the LAMBDA 950/850/650 Series provides reputation for excellence, along with our outstanding
the high standards of results, accuracy and quality that have made PerkinElmer the industry leader. global service organization.
and UV/Vis sampling. Or, for industry-specific questions and instrumentation information, contact delivering the highest reliability and data integrity
• Highest performance UV/Vis system
a PerkinElmer representative at 1 (800) 250-6070 ext. 800 or visit www.perkinelmer.com/lambda. on the most demanding of samples. Whether you
need to measure the absolute reflectance of coatings • Wavelength range: 175 nm – 900 nm
at variable angles, characterize optical filters, or
Yours truly, • UV/Vis resolution: 0.05 nm – 5.00 nm
analyze highly absorbing liquids, the LAMBDA™
950/850/650 Series produces the most consistent,
The facts at a glance
accurate results in the industry.
Increased flexibility and convenience pp. 4-5 UV-Vis
Setting the standard for convenience
Designed for demanding analysis LAMBDA 650
Engineered with smart flexibility
The Universal Reflectance Accessory (URA) 190 nm 900 nm
With a wide-range of intelligent modules that snap
Maximum versatility delivering pp. 6-7 in and out easily, the LAMBDA Series can handle • Upgradeable, flexible UV/Vis at
Peter Coggins, PhD optimal performance
your laboratory’s most demanding analyses. Our a cost-effective price
President
System specifications pp. 8-9
PerkinElmer innovative new high-performance optical bench, • Wavelength range: 190 nm – 900 nm
Life and Analytical Sciences Inside the LAMBDA pp. 10-11 intelligent accessories, large automated sampling
UV WinLab™ software p. 12
• UV/Vis resolution: 0.17 nm – 5.00 nm
compartments and easy-to-use analytical software
Maximum flexibility
Security features with professional workflow make the new LAMBDA
950/850/650 Series the industry’s most capable
PerkinElmer support and service p. 13
UV/Vis/NIR and UV/Vis instruments.
2 w w w. p e r k i n e l m e r. c o m 3
increased flexibility and convenience
from the world leader in UV/Vis/NIR and UV/Vis
optical mounts allows you to create a customized optical Standard Transmission Optics – Including ultra-high
system to handle a wide range of sample types – sensitivity UV/Vis and NIR detectors for demanding
including lenses and telescopes – giving your lab transmission measurements on liquids and solids.
the ultimate in flexibility.
4 See inside spread for details. w w w. p e r k i n e l m e r. c o m 5
Universal Reflectance Unmatched sample Industry’s only dual Snap-in integrating
Accessory (URA) compartment size sampling compartments spheres to 150 mm
• Unique to PerkinElmer • Additional room to • Snap-in/snap-out for • 60 mm, 150 mm and
• Snap-in module, changes mount samples maximum flexibility detector sphere modules,
angle automatically • More room to work • Compartments are quickly in addition to specialist
and easily reconfigured options
• No alignment or • Ability to mount polarizers
adjustment required and depolarizers • Extra space available for • Transmission, eight-degree
samples, accessories and reflectance and center
large integrating spheres mount capability
• LAMBDATM 650 is the only
instrument in its class
maximum
offering a true 150 mm
integrating sphere
Tackles difficult transmission General Purpose Optical Bench Sampling modules require
analyses with ease (GPOB) handles a wide range of only seconds to change
samples – including lenses and
• High-sensitivity transmission • Easily changeable to
telescopes
measurements on liquids accommodate next
and solids • Replaces both compartments,
sample requirement
creating very large sampling area
• Turbid and cloudy samples, • Sample variety will no
including DNA, proteins • Can be configured for custom
longer be a bottleneck
and blood optical layouts Taking out the transmission module and replacing it with the Universal Reflectance Accessory (URA)
• Broader range of users able
• Cell changers speed • Accommodates large and
to run different analyses
and simplify multi-sample awkwardly shaped samples such Call 1 (800) 250-6070 ext. 800* to arrange a FREE CONSULTATION
as optics, lenses and beamsplitters
measurements with a PerkinElmer LAMBDA specialist, or e-mail us: lambda@perkinelmer.com
www.perkinelmer.com/lambda
*Phone number is for U.S. and Canada only. For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices
6 7
three models – choose the system with the
specifications you need
The LAMBDA™ Series of UV/Vis/NIR and UV/Vis spectrophotometers is the industry standard
for high performance, flexibility and convenience. Each model includes the same range of
modular components and snap-in accessories to tackle a range of tough applications. Whatever
specifications your laboratory requires, the LAMBDA Series provides best-in-class accuracy,
precision and reproducibility.
Optical System All-reflecting optical system (SiO2 coated) with holographic grating monochromators. Littrow mounting, sample
thickness compensated detector optics.
1
DOUBLE HOLOGRAPHIC 8
GRATING MONOCHROMATORS 2 2
For ultra-low stray light
1
performance. LARGEST SAMPLE
7 COMPARTMENT IN
7 THE INDUSTRY
3 Allows easy access to a wide
COMMON BEAM MASK variety of sampling accessories
Allows precise adjustment of 3 and sample types.
beam height to match samples 6
of different dimensions.
5 HIGH-SENSITIVITY
COMMON BEAM DEPOLARIZER
4 8 PHOTOMULTIPLIER AND
Corrects for inherent instrument 6 PELTIER-CONTROLLED
polarization to allow accurate PbS DETECTORS
measurements of birefringent Provides full range UV/Vis/NIR
samples (optional). coverage from 175 to 3,300 nm
(LAMBDA 950 only).
CHOPPER
Switches between sample and reference beam. 5 4
Four-segment design provides individual blank SECOND SAMPLING AREA
readings for sample and reference, increasing
9 Houses a range of snap-in
measurement accuracy. sampling modules including
transmission optics (shown),
60 mm and 150 mm integrating
spheres and the Universal
Reflectance Accessory (URA)
for high-precision absolute
Another PerkinElmer reflectance measurements.
exclusive
All three of the LAMBDA™ Series instruments
feature unmatched polarization measurement
capabilities to match your analytical needs.
12 13
LAMBDA UV/Vis/NIR and UV/Vis spectrophotometers:
powered by PerkinElmer
PerkinElmer, Inc. is a global technology leader regulatory requirements, improve time-to-market,
focused in the following businesses – Life and and increase manufacturing efficiencies.
Analytical Sciences, Optoelectronics, and Fluid
Preferred for years by laboratories worldwide,
Sciences. A $1 billion market leader, the Life and
the LAMBDA™ Series is the premier range of
Analytical Sciences division serves a large number
high-performance UV/Vis/NIR and UV/Vis
of industries, including the academic research,
spectrophotometers, providing accurate, stable
biotechnology, clinical screening, pharmaceutical,
and repeatable results. All three models share
environmental, forensic, petrochemical and
the same high-performance optical bench, allowing
semiconductor segments.
each one to use the same array of intelligent
Our instruments and related software and customer sampling accessories. For sampling flexibility,
support programs, including our OneSourcesm team ease-of-use and superior data quality, the
of over 1,000 factory-trained service professionals PerkinElmer LAMBDA 950/850/650 Series
deployed in over 125 countries, help our customers spectrophotometers are the industry-standard
to enhance research productivity, meet strict for excellence.
©2004 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. Enhanced Security, LAMBDA, and UV WinLab are
trademarks and OneSource is a service mark of PerkinElmer, Inc. or its subsidiaries, in the United States and other countries. All other trademarks not owned by PerkinElmer,
Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change this document at any time and disclaims
liability for editorial, pictorial or typographical errors.