Professional Documents
Culture Documents
Date
D0468 Jan-05
DESIGN CALCULATION
SHEET Sheet No. Computed by
of T. Hassan
Footing ID: f2
Ultimate Column Load = 220.00 t A1 = 0.20 m2
Service Column Load = 146.67 t A2 = 4.70 m2
Plain Concrete Dimensions Chosen Plain Concrete Dimensions Reinforced Concrete Dimensions
Length = 3.40 m Length = 3.50 m Length = 3.50 m
Width = 3.05 m Width = 3.20 m Width = 3.20 m
Thickness = 0.20 m Thickness = 0.20 m Thickness = 0.85 m
Depth = 0.75 m
Final stress under P. C. footing = 13.73 t/m2 (Safe)
Final stress under R. C. footing = 13.69 t/m2 (Safe)
Nominal Bearing strength of column = 348.08 t (Safe)
Nominal Bearing strength of footing = 696.15 t (Safe)
Footing Reinforcement I
Bearing Pressure (Ultimate Load) = 20.48 t/m2 tpc
Max. Ult. Bending Moment (Sect. I-I) = 24.37 m t/ m' II
Max. Ult. Bending Moment (Sect. II-II) = 25.23 m t/ m' Wrc
Bar sizes to be chosen are ( 12, 16, 20, 22, 25, 32, 40)
tpc
As I-I = 15 cm2 (Asmin) As I-I(chosen) = 8 f 16 / m'
As II-II = 15 cm2 (Asmin) As II-II(chosen) = 8 f 16 / m'
r = 0.07 rb tpc Lrc tpc
where, bc is the ratio of long side to short side of the column, concentrated load or reaction area
and, as is 40 (for interior columns)