Safety fittings for hygienic applications 7.

Hygienic 400
Safety valve made of
stainless steel, angle type,
→ Series Hygienic 400 with stainless steel spring

SUITABLE FOR

Liquids neutral and non-neutral

Air, gases and vapours neutral and non-neutral

Steam

EXAMPLES OF USE
F

For the protection of:


L
- processes, plants and containers in the food and pharmaceutical industry
for air, neutral and non-neutral vapours and gases, steam and liquids D
taking into account the operation- and plant-specific regulations and making use
of the suitable valve version and sealing material. W
• food industry • cosmetic industry
• breweries and beverage industry • medical technology
• pharmaceutical industry • clean Service applications
FEATURES

- Smooth and faultless surface finish optimized for cleaning process


- Minimal dead space in inlet area and no gaps in the valve
- Exposed and rinsed o-ring seals
- Shape of valve body avoids forming of puddles in the valve after it has opened
- Possible to carry-out CIP/SIP by lifting the disc from the seat
- Gap-free installation of seals
- Surface roughness standard Ra<0,8 um
- Option: mechanically polished and/or electro-polished

TS
APPROVALS

TÜV-Type test approval 2062 D/G, F, F/K/S


MATERIAL EC type examination S/G, L, F/K/S
TSG ZF001-2006 S/G, L, F/K/S
KGS G
TR ZU 032/2013 - TR ZU 010/2011 S/G, L, F/K/S
EHEDG
DGUV Test
SPECIFICATION Requirements
DIN EN ISO 4126-1 TRD 421
PED 2014/68/EU AD 2000 Data sheet A2
TRB 801 No. 22 and 23 KGS AA 319

Additional hygienic requirements


EG No. 852/2004 GS-NG 2 and 5
Clamp –40°C to + 200°C 0,4–16 bar
DIN EN 1672-2 EHEDG Aseptik
connection 9. GPSGV
DN 20 – DN 32
Classification society
Germanischer Lloyd GL
Det Norske Veritas DNV
Bureau Veritas BV
Russian Maritime Register of Shipping RS

MATERIALS

Component Material DIN EN ASME


Body Stainless steel 1.4435 316 L
Inner parts, wetted Stainless steel 1.4435 316 L
Upper section, other inner parts Stainless steel 1.4404 316 L
Spring Stainless steel 1.4310 302
Bellows Stainless steel 1.4571 316 Ti
Series 400 VALVE VERSION

for neutral and non-neutral media and/or counter pressure up to 4 bar.


b Standard with bellows
Spring, moving parts and the environment are protected from being affected by the medium.

Parts which are difficult to clean in the guide, the spring housing and the spindle / disc combination are protected against soiling by stainless steel
bellows

MEDIUM

Air, vapours, gases, liquids and - depending on safety valve version and seal
GF gaseous and liquid - also for steam

T YPE OF LIF TING MECHANISM

K Standard with twist-type lifting mechanism

AVAILABLE NOMINAL DIAMETERS AND CONNECTION SIZES

Nominal diameter 20
Connection type Clamp connection Threaded ferrule connection
DIN 11864-3 / DIN 11853-3 DIN 32676 DIN 11864-1 / DIN 11853-1 DIN 11851

Inlet DN 20 DN 25 DN 32 DN 20 DN 25 DN 32 DN 20 DN 25 DN 20 DN 25
DN 25 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Outlet

DN 32 ■ ■ ■ ■ ■ ■

T YPE OF CONNECTION INLET / OUTLET Special connections

Aseptic collar clamp connection / DIN 11864-3 / DIN 11864-3 Pipe Standard
A/A Standard
Aseptic collar clamp connection DIN 11853-3 / DIN 11853-3 DIN 11850
Pipe Standard
KLSDIN / KLSDIN On request Clamp connection / Clamp connection DIN 32676 / DIN 32676
DIN 11850

Against surcharge

Aseptic-Threaded ferrule connection A/ DIN 11864-1 / DIN 11864-1 Pipe Standard


N/N
Aseptic-Threaded ferrule connection A DIN 11853-1 / DIN 11853-1 DIN 11850
Threaded ferrule connection / Pipe Standard
GSDIN / GSDIN DIN 11851 / DIN 11851
Threaded ferrule connection DIN 11850
Further connection types available on request

SEALS

FKM Fluorcarbon Elastomere moulded seal FDA, USP, 3-A, ADI-free –20°C to +200°C
EPDM Ethylene propylene diene Elastomere moulded seal FDA –40°C to +170°C

OPTIONS

Surface mechanically polished MP


Surface mechanically polished and electro-polished MEP
Special versions on request.
NOMINAL DIAMETERS, CONNECTIONS, INSTALLATION DIMENSIONS

Series Hygienic 400: Connection, installation dimensions, ranges of adjustment


Nominal diameter DN 20
Connection Aseptic collar clamp connection DIN 11864-3 / DIN 11853-1 Aseptic-Threaded ferrule connection A DIN 11864-1 / DIN 11853-1
Clamp connection DIN 32676 Threaded ferrule connection DIN 11851

Inlet DN 20 25 32 20 25
G - - - 20 (Rd 44 x 1/6") 25 (Rd 52 x 1/6")
Outlet DN1 25, 32 25, 32 32 25 25
G1 - - - 25 (Rd 52 x 1/6") 25 (Rd 52 x 1/6")
Installation dimensions in mm L - - - 75 75
L1 65 65 65 - -
H 145 145 145 145 145
h 29 29 29 - -
h1 - - - 40 40
D 34 50,5 50,5 - -
D1 50,5 50,5 50,5 - -
do 18 18 18 18 18
Weight kg 1,3 1,3 1,3 1,4 1,4
Range of adjustment bar 0,4-16 0,4-16 0,4-16 0,4-16 0,4-16

MAIN DIMENSIONS, INSTALL ATION DIMENSIONS

INDIVIDUAL SELECTION / VALVE CONFIGURATION

Series Valve Medium Lifting Nominal Connection type Connection size Seal Options Set Quantity
version device diameter pressure
DN Inlet Outlet Inlet Outlet
400 b GF K 20 A A 25 25 FKM MEP 2,5 2

400 b GF K 20 KLSDIN KLSDIN 20 25 EPDM MP 3,2 1

400 b GF K 20
400 b GF K 20
400 b GF K 20
CAPACIT Y TABLE

Series Hygienic 400: Blowing-off rates at 10% above set pressure


Nominal diameter DN 20
Set pressure bar I II III
0,5 127 96 3,1
1 189 151 4,5
1,5 257 204 6,7
2 332 262 7,7
Air I 2,5 390 305 8,6
Nm³/h 3 447 349 9,4
3,5 504 392 10,2
4 561 435 10,9
Steam II 4,5 618 478 11,5
kg/h 5 675 521 12,2
5,5 732 564 14,0
6 790 608 14,6
Water III
6,5 847 650 15,2
m³/h 7 904 692 15,8
7,5 961 735 16,4
8 1018 777 16,9
8,5 1075 820 17,4
9 1132 862 17,9
9,5 1190 905 18,4
10 1247 947 18,9
11 1361 1031 19,8
12 1475 1115 20,7
13 1590 1199 21,6
14 1704 1284 23,4
15 1818 1368 24,2
16 1932 1453 25,0
Subject to technical modifications.
Safety fittings for hygienic applications 7.2

Hygienic 400.5
Overflow / Pressure control
valve made of stainless steel,

Series Hygienic 400.5


angle type
→ –External adjustment–

SUITABLE FOR

Liquids neutral and non-neutral

Air, gases and vapours neutral and non-neutral

Steam

F
EXAMPLES OF USE
L
For the protection of: D
- Pumps against overloading in closed circuits for neutral / non-neutral
liquids
For the control of: W
- processes, plants and containers in the food and pharmaceutical
industry for air, neutral and non-neutral vapours and gases, steam and
liquids
• food industry
• breweries and beverage industry
• pharmaceutical industry
• cosmetic industry
• medical technology
• clean Service applications

FEATURES

- Smooth and faultless surface finish optimized for cleaning process


- Minimal dead space in inlet area and no gaps in the valve
- Exposed and rinsed o-ring seals
- Shape of valve body avoids forming of puddles in the valve
MATERIAL - Adjustable and settable during operation
- Possible to carry-out CIP/SIP by lifting the disc from the seat
- Gap-free installation of seals
- Surface roughness standard Ra<0,8 um
- Option: mechanically polished and/or electro-polished

APPROVALS
SPECIFICATION
TR ZU 032/2013 - TR ZU 010/2011
DGUV Test
REQUIREMENTS
DGR 97/23/EG
Clamp –40°C to + 200°C 0,4 – 16 bar
Additional hygienic requirements
connection
EG No. 852/2004 9. GPSGV
DN 20 – DN 32
DIN EN 1672-2 GS-NG 2 and 5
Classification society
Russian Maritime Register of Shipping RS
Germanischer Lloyd GL

MATERIALS

Component Material DIN EN ASME


Body Stainless steel 1.4435 316 L
Inner parts, wetted Stainless steel 1.4435 316 L
Upper section, other inner parts Stainless steel 1.4404 316 L
Spring Stainless steel 1.4310 302
Bellows Stainless steel 1.4571 316 Ti
Series 400.5 VALVE VERSION

for neutral and non-neutral media and/or counter pressure up to 4 bar.


b Standard with bellows
Spring, moving parts and the environment are protected from being affected by the medium.

Parts which are difficult to clean in the guide, the spring housing and the spindle / disc combination are protected against soiling by stainless steel
bellows

Valves can be delivered unset within a pressure range or set and sealed at the factory.
Can be adjusted by hand wheel under operating conditions without medium escaping into the environment.

MEDIUM

Air, vapours, gases, liquids and - depending on safety valve version and seal
GF gaseous and liquid - also for steam

T YPE OF LIF TING MECHANISM

K Standard with twist-type lifting mechanism

AVAILABLE NOMINAL DIAMETERS AND CONNECTION SIZES

Nominal diameter 20
Connection type Clamp connection Threaded ferrule connection
DIN 11864-3 / DIN 11853-3 DIN 32676 DIN 11864-1 / DIN 11853-1 DIN 11851

Inlet DN 20 DN 25 DN 32 DN 20 DN 25 DN 32 DN 20 DN 25 DN 20 DN 25
DN 25 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Outlet

DN 32 ■ ■ ■ ■ ■ ■

T YPE OF CONNECTION INLET / OUTLET Special connections

Aseptic collar clamp connection / DIN 11864-3 / DIN 11864-3 Pipe Standard
A/A Standard
Aseptic collar clamp connection DIN 11853-3 / DIN 11853-3 DIN 11850
Pipe Standard
KLSDIN / KLSDIN On request Clamp connection / Clamp connection DIN 32676 / DIN 32676
DIN 11850

Against surcharge

Aseptic-Threaded ferrule connection A/ DIN 11864-1 / DIN 11864-1 Pipe Standard


N/N
Aseptic-Threaded ferrule connection A DIN 11853-1 / DIN 11853-1 DIN 11850
Threaded ferrule connection / Pipe Standard
GSDIN / GSDIN DIN 11851 / DIN 11851
Threaded ferrule connection DIN 11850
Further connection types available on request

SEALS

FKM Fluorcarbon Elastomere moulded seal FDA, USP, 3-A, ADI-free –20°C to +200°C
EPDM Ethylene propylene diene Elastomere moulded seal FDA –40°C to +170°C

OPTIONS

Surface mechanically polished MP


Surface mechanically polished and electro-polished MEP
Special versions on request.
NOMINAL DIAMETERS, CONNECTIONS, INSTALLATION DIMENSIONS

Series Hygienic 400.5: Connection, installation dimensions, ranges of adjustment


Nominal diameter DN 20
Connection Aseptic collar clamp connection DIN 11864-3 / DIN 11853-1 Aseptic-Threaded ferrule connection A DIN 11864-1 / DIN 11853-1
Clamp connection DIN 32676 Threaded ferrule connection DIN 11851

Inlet DN 20 25 32 20 25
G - - - 20 (Rd 44 x 1/6") 25 (Rd 52 x 1/6")
Outlet DN1 25, 32 25, 32 32 25 25
G1 - - - 25 (Rd 52 x 1/6") 25 (Rd 52 x 1/6")
Installation dimensions in mm L - - - 75 75
L1 65 65 65 - -
H 145 145 145 145 145
h 29 29 29 - -
h1 - - - 40 40
D 34 50,5 50,5 - -
D1 50,5 50,5 50,5 - -
do 18 18 18 18 18
Weight kg 1,3 1,3 1,3 1,4 1,4
Set pressure bar 0,4-16 0,4-16 0,4-16 0,4-16 0,4-16
Range of adjustment bar 0,4 - 1,5 0,4 - 1,5 0,4 - 1,5 0,4 - 1,5 0,4 - 1,5
1,5 - 4,5 1,5 - 4,5 1,5 - 4,5 1,5 - 4,5 1,5 - 4,5
4,5 - 7 4,5 - 7 4,5 - 7 4,5 - 7 4,5 - 7
7 - 10 7 - 10 7 - 10 7 - 10 7 - 10
10 - 14 10 - 14 10 - 14 10 - 14 10 - 14
14 - 16 14 - 16 14 - 16 14 - 16 14 - 16

MAIN DIMENSIONS, INSTALL ATION DIMENSIONS

INDIVIDUAL SELECTION / VALVE CONFIGURATION

Series Valve Medium Lifting Nominal Connection type Connection size Seal Options Set Quantity
version device diameter pressure
DN Inlet Outlet Inlet Outlet
400.5 b GF K 20 A A 25 25 FKM MEP 1,5–4,5 2

400.5 b GF K 20 GSDIN GSDIN 25 25 EPDM – 3,5 1

400.5 b GF K 20
400.5 b GF K 20
400.5 b GF K 20
CAPACIT Y TABLE

Series Hygienic 400.5: Kv values at 1 bar overpressure


Nominal diameter DN 20
Air [Nm³/h]
Pressure range bar 0,4 - 1,5 1,5 - 4,5 4,5 - 7 7 - 10 10 - 14 14 - 16
Set pressure bar
0,4 215
1,0 278
1,5 318 330
3,0 455
4,5 596 398
5,7 428
7,0 482 424
8,5 435
10,0 444 442
12,0 531
14,0 619 415
15,0 433
16,0 510

Kv values at 1 bar overpressure


Nominal diameter DN 20
Water [m³/h]
Pressure range bar 0,4 - 1,5 1,5 - 4,5 4,5 - 7 7 - 10 10 - 14 14 - 16
Set pressure bar
0,4 7
1,0 7,5
1,5 8,1 6,7
3,0 8,2
4,5 9,9 7,0
5,7 8,1
7,0 9 7,5
8,5 8,5
10,0 9,1 6,9
12,0 7,4
14,0 8,8 4,9
15,0 6,0
16,0 6,3

Kv values at 1 bar overpressure


Nominal diameter DN 20
Steam [kg/h]
Pressure range bar 0,4 - 1,5 1,5 - 4,5 4,5 - 7 7 - 10 10 - 14 14 - 16
Set pressure bar
0,4 163
1,0 224
1,5 250 195
3,0 360
4,5 466 306
5,7 331
7,0 374 325
8,5 336
10,0 340 336
12,0 408
14,0 466 317
15,0 337
16,0 380
Safety fittings for hygienic applications 7.3

Hygienic 4000
Safety valve made of
stainless steel, angle type,
→ Series Hygienic 4000 with stainless steel spring

SUITABLE FOR

m Liquids neutral and non-neutral


ble fro
Availa 2017
April
Air, gases and vapours neutral and non-neutral

Steam

F
EXAMPLES OF USE

For the protection of: L


- processes, plants and containers in the food and pharmaceutical industry D
for air, neutral and non-neutral vapours and gases, steam and liquids
• food industry • cosmetic industry
• Dairy industry • medical technology W
• breweries and beverage industry • clean Service applications
• pharmaceutical industry

FEATURES

- Smooth and faultless surface finish optimized for cleaning process


- Minimal dead space in inlet area and no gaps in the valve
- Exposed and rinsed o-ring seals
- Shape of valve body avoids forming of puddles in the valve after it has opened
- Suitable for CIP/SIP due to pneumatic lifting device
- Gap-free installation of seals in contact with the medium
- Surface roughness standard Ra<0,8 um
- Option: mechanically polished and/or electro-polished
- Moulded diaphragm to divide the product chamber from the spring housing

APPROVALS

TÜV-Type test approval 2095 D/G, F


MATERIAL
EC type examination S/G, L
TR ZU 032/2013 - TR ZU 010/2011 S/G, L
Requirements
DIN EN ISO 4126-1 AD 2000 Data sheet A2
PED 2014/68/EU VdTÜV Guideline SV 100
SPECIFICATION TRD 421

Clamp –40°C to + 200°C 0,4–16 bar


connection
DN 25 – DN 100

MATERIALS

Component Material DIN EN ASME


Body Stainless steel 1.4404 316 L
Inner parts, wetted Stainless steel 1.4404 316 L
Upper section, other inner parts Stainless steel 1.4404 316 L
Spring Stainless steel 1.4310 302
Diaphragm Elastomer FKM, EPDM FKM, EPDM
Series 4000 VALVE VERSION

for neutral and non-neutral media.


t Standard with diaphragm
Spring, moving parts and the environment are protected from being affected by the medium.

Parts which are difficult to clean in the guide, the spring housing and the spindle / disc combination are protected against soiling by elastomer diaphragm.

MEDIUM

Air, vapours, gases, liquids and - depending on safety valve version and seal
GF gaseous and liquid - also for steam

T YPE OF LIF TING MECHANISM

P Pneumatic lifting device


O without lifting device

AVAILABLE NOMINAL DIAMETERS AND CONNECTION SIZES

Nominal diameter 25 40 50 65 80 100


Inlet 25 40 50 65 80 100
40 ■
65 ■
80 ■
Outlet DN

100 ■
125 ■
150 ■

T YPE OF CONNECTION INLET / OUTLET Special connections

Pipe Standard
KLSDIN / KLSDIN Standard Clamp connection / Clamp connection DIN 32676 / DIN 32676
DIN 11850
Against surcharge
Aseptic-Threaded ferrule connection A/ DIN 11864-1 / DIN 11864-1 Pipe Standard
N/N
Aseptic-Threaded ferrule connection A DIN 11853-1 / DIN 11853-1 DIN 11850
Threaded ferrule connection / Pipe Standard
GSDIN / GSDIN DIN 11851 / DIN 11851
Threaded ferrule connection DIN 11850
Further connection types available on request

SEALS

FKM Fluorcarbon Elastomere moulded seal FDA, USP –20°C to +200°C


EPDM Ethylene propylene diene Elastomere moulded seal FDA, USP –40°C to +170°C

OPTIONS

Surface mechanically polished MP


Surface mechanically polished and electro-polished MEP
Proximity switch for indication of valve position Order description: S62
Special versions on request.
NOMINAL DIAMETERS, CONNECTIONS, INSTALLATION DIMENSIONS

Series Hygienic 4000: Connection, installation dimensions, ranges of adjustment


Nominal diameter DN 25 40 50 65 80 100
Connection Clamp connection DIN 32676
Inlet DN 25 40 50 65 80 100
Outlet DN1 40 65 80 100 125 150
Installation dimensions in mm L 80 120 140 153 178 181
h 47 64 80 92 112 126
D 51 51 64 91 106 119
D1 51 91 106 119 155 183
H 183 285 354 445 513 586
H12) 216 335 414 515 613 701
αw / Kdr (F) 0,45 0,45 0,45 0,45 0,45 0,45
αw / Kdr (D/G)1) 0,70 0,70 0,70 0,70 0,70 0,70
do 23,0 37,0 46,0 60,0 74,0 92,0
Weight tGFO kg 2,2 7,0 13,0 24,5 41,3 64,0
Weight tGFP kg 2) 3 8 15 29 50 76
Range of adjustment bar 0,4-16 0,4-16 0,4-16 0,4-16 0,4-16 0,4-16
1)
Coefficient of flow for S/G valid for 6,00 bar or more, for smaller set pressures see values in capacity table
2)
Values for version with pneumatic lifting device

MAIN DIMENSIONS, INSTALL ATION DIMENSIONS

INDIVIDUAL SELECTION / VALVE CONFIGURATION

Series Valve Medium Lifting Nominal Connection type Connection size Seal Options Set Quantity
version device diameter pressure
DN Inlet Outlet Inlet Outlet
4000 t GF P 25 KLSDIN KLSDIN 25 40 EPDM MP 3,2 1

4000 t GF
4000 t GF
4000 t GF
4000 t GF
CAPACIT Y TABLE

Series Hygienic 4000: Blowing-off rates at 10% above set pressure


Nominal diameter DN 25 40 50
Set pressure bar d0 = 23 mm d0 = 37 mm d0 = 46 mm
I II III I II III I II III
0,4 88,1 177,5 6,6 227,9 459,4 17,2 352,2 710,1 26,6
0,7 117,4 230,2 8,5 303,7 595,9 21,9 469,5 921,0 33,8
Air I 1 352,7 280,8 9,9 912,8 726,7 25,7 1410,9 1123,2 39,7
Nm³/h 1,5 477,8 377,6 12,2 1236,4 977,1 31,5 1911,0 1510,3 48,8
2 596,3 468,5 14,1 1543,1 1212,4 36,5 2385,2 1873,9 56,4
Steam II 2,5 713,4 557,8 15,8 1846,2 1443,4 40,8 2853,5 2231,1 63,0
kg/h 3 830,2 646,5 17,3 2148,5 1673,0 44,7 3320,9 2585,9 69,1
3,5 945,5 733,6 18,7 2446,8 1898,5 48,3 3782,0 2934,4 74,6
Water III 4 1058,7 818,9 20,0 2739,7 2119,2 51,6 4234,7 3275,6 79,8
m³/h 4,5 1171,1 903,4 21,2 3030,8 2337,9 54,8 4684,5 3613,6 84,7
5 1284,4 988,4 22,3 3324,0 2558,0 57,8 5137,8 3953,7 89,3
5,5 1398,3 1073,6 23,4 3618,6 2778,5 60,6 5593,0 4294,6 93,6
6 1507,3 1155,0 24,5 3900,9 2989,1 63,3 6029,4 4620,2 97,8
6,5 1616,4 1236,5 25,5 4183,2 3200,0 65,9 6465,7 4946,1 101,8
7 1725,5 1317,9 26,4 4465,5 3410,7 68,4 6902,0 5271,7 105,7
7,5 1834,6 1399,2 27,3 4747,8 3621,0 70,8 7338,4 5596,8 109,4
8 1943,7 1480,3 28,2 5030,0 3831,0 73,1 7774,7 5921,4 113,0
8,5 2052,8 1561,4 29,1 5312,3 4040,8 75,3 8211,1 6245,7 116,4
9 2161,8 1642,5 30,0 5594,6 4250,5 77,5 8647,4 6569,9 119,8
9,5 2270,9 1723,6 30,8 5876,9 4460,4 79,7 9083,7 6894,3 123,1
10 2380,0 1804,6 31,6 6159,2 4670,1 81,7 9520,1 7218,4 126,3
11 2598,2 1966,8 33,1 6723,8 5089,8 85,7 10392,7 7867,1 132,5
12 2816,4 2128,6 34,6 7288,4 5508,7 89,5 11265,4 8514,5 138,4
13 3034,5 2290,2 36,0 7853,0 5926,9 93,2 12138,1 9160,9 144,0
14 3252,7 2452,5 37,4 8417,6 6346,9 96,7 13010,7 9810,2 149,5
15 3470,9 2614,8 38,7 8982,2 6766,8 100,1 13883,4 10459,2 154,7
16 3689,0 2776,4 40,0 9546,8 7185,0 103,4 14756,1 11105,6 159,8
CAPACIT Y TABLE

CONTINUATION - Series Hygienic 4000: Blowing-off rates at 10% above set pressure
Nominal diameter DN 65 80 100
Set pressure bar d0 = 60 mm d0 = 74 mm d0 = 92 mm
I II III I II III I II III
0,4 599,3 1208,0 45,2 911,6 1837,6 68,8 1409,0 2840,2 106,4
0,7 798,7 1566,9 57,5 1214,9 2383,4 87,5 1877,9 3684,0 135,2
Air I 1 2400,4 1911,0 67,6 3651,2 2906,8 102,8 5643,6 4493,0 158,9
Nm³/h 1,5 3251,2 2569,5 82,9 4945,5 3908,5 126,2 7644,0 6041,2 195,0
2 4057,9 3188,2 95,9 6172,6 4849,6 145,8 9540,6 7495,8 225,4
Steam II 2,5 4854,8 3795,8 107,3 7384,7 5773,8 163,2 11414,2 8924,3 252,2
kg/h 3 5649,9 4399,5 117,5 8594,2 6692,1 178,8 13283,6 10343,7 276,4
3,5 6434,3 4992,4 127,0 9787,3 7594,0 193,2 15127,8 11737,6 298,6
Water III 4 7204,5 5572,9 135,8 10958,9 8477,0 206,6 16938,6 13102,5 319,3
m³/h 4,5 7969,9 6148,0 144,1 12123,1 9351,8 219,1 18738,1 14454,6 338,7
5 8741,0 6726,6 151,9 13296,1 10231,9 231,0 20551,2 15814,9 357,1
5,5 9515,6 7306,5 159,3 14474,2 11114,0 242,3 22372,1 17178,4 374,5
6 10257,9 7860,4 166,4 15603,4 11956,5 253,1 24117,5 18480,6 391,2
6,5 11000,3 8414,9 173,2 16732,6 12800,0 263,5 25862,8 19784,3 407,2
7 11742,6 8968,9 179,8 17861,8 13642,7 273,4 27608,2 21086,9 422,6
7,5 12485,0 9522,0 186,1 18991,0 14484,1 283,0 29353,5 22387,3 437,5
8 13227,3 10074,2 192,2 20120,2 15323,9 292,3 31098,9 23685,5 451,9
8,5 13969,7 10626,0 198,1 21249,4 16163,4 301,4 32844,2 24983,0 465,8
9 14712,0 11177,4 203,9 22378,6 17002,1 310,1 34589,5 26279,4 479,3
9,5 15454,3 11729,5 209,5 23507,8 17841,8 318,6 36334,9 27577,2 492,5
10 16196,7 12280,8 214,9 24637,0 18680,4 326,9 38080,2 28873,5 505,3
11 17681,4 13384,5 225,4 26895,4 20359,3 342,9 41570,9 31468,4 530,0
12 19166,1 14486,0 235,4 29153,8 22034,7 358,1 45061,6 34058,1 553,5
13 20650,8 15585,7 245,1 31412,1 23707,6 372,8 48552,3 36643,7 576,2
14 22135,5 16690,2 254,3 33670,5 25387,7 386,9 52043,0 39240,6 597,9
15 23620,2 17794,4 263,3 35928,9 27067,3 400,4 55533,7 41836,7 618,9
16 25104,9 18894,2 271,9 38187,3 28740,2 413,6 59024,4 44422,4 639,3