GIGAQUIT NATIONAL SCHOOL OF HOME INDUSTRIES

Electrical Installation and Maintenance NC II


Fourth Periodical Examination
Grade 10

Name:_____________________________________ Score:_________________

I. Multiple Choice. Choose the correct answer. Write your answer in the space provider. Strictly NO ERASURE
______1. The correct standard size of wire installation in lighting commonly in residential houses?
a. 2.0mm b. 3.5mm c. 5.5mm d. 8.0mm
______2. The conduits come in 10 feet length and ranging in size from ½ to 4 ½ inches.
a. plastic moldingb. cable armored c. pvc pipe d. knob and tube
______3. kind of equipment that we use to heat the conduit pipe like PVC to make desire bend.
a. heckey b. hydraulic bend c. blow torch d. rebar bender
______4. A material uses to pull electrical wire easily inside the conduit pipe.
a. fish wire b. electrical wire c. string d. combination plier
______5. Materials use to fasten the conduit to concrete walls, it has a varied size depends on conduit size.
a. conduit pipe b. coupling c. condulets d. conduit clamp
______6. The materials have an inner threading which fits and joints the lengths of conduits.
a. conduit pipe b. coupling c. condulets d. conduit clamp
______7. When you cut conduit pipe, what kind of equipment or holding tools use to hold the pipe?
a. electric heat gun b. pipe vise c. heckey d. safety breaker
______8. What kind of conduit pipe use to make entrance service drop wire in residential and commercial building?
a. plastic moldingb. pipe vise c. RSC d. 100A
______9. The standard height of flush type switch in residential house or commercial building?
a. 1.20m b. 1.30mc. 1.40m d. 1.50m
______10. The standard height of flush type out in residential house or commercial building?
a. 0.3m b. 0.4m c. 0.5m d. 0.6m

II. TRUE or FALSE. Write true if the statement is True, then false if the statement is False
______11. The entire conduit system should not be grounded to prevent shock and to eliminate fire hazards.
______12. There should be more than four bends in any one conduit from outlet to outlet.
______13. Do not Use suitable outlet boxes or fitting and junction points.
______14. For open conduit work, not suitable straps or clamps should be used.
______15. Conduits should not be joined to each other by couplings. They have threads at the ends for this purpose.

III. Complete the table below. Minimum size of conduit in inches

Size of wire 1 wire 2 wires 3 wires 4 wires

14 1/2 3/4

3/4
12
1/2 3/4
10
1 1
8
1/2 1 -1 / 4
6
1–1/2
4
3/ 4
2
1- 1 / 4
0
IV. Label the parts of the typical overhead & underground service entrance.