You are on page 1of 34

MEMORIA DE

CALCULO ESTRUCTURAL

PROYECTO: VIVIENDA MULTIFAMILIAR


DEPARTAMENTO: MOQUEGUA
PROVINCIA: ILO
DISTRITO: PACOCHA

PROPIETARIO: Sr. Saravia Gallegos, Jorge Luciano


Sra. Dongo de Saravia, Estela Zoraida

CONSULTOR: ARQ. Marco Antonio Chambi Mamani

DICIEMBRE - 2018
MEMORIA DE CALCULO ESTRUCTURAL

CONTENIDO

1. GENERALIDADES ...................................................................................................................... 3

1.1. ESTRUCTURACION ............................................................................................................ 3

1.2. NORMAS EMPLEADAS ...................................................................................................... 3

1.3. ESPECIFICACIONES – MATERIALES EMPLEADOS ...................................................... 3

1.4. CARACTERISTICAS DEL TERRENO Y CONSIDERACIONES DE CIMENTACION .... 4

1.5. REFERENCIAS ..................................................................................................................... 5

2. ESTADOS Y COMBINACIONES DE CARGA: ....................................................................... 13

2.1. ESTADOS DE CARGAS ..................................................................................................... 13

2.2. COMBINACIONES DE CARGAS...................................................................................... 13

2.3. ALTERNANCIA DE CARGAS .......................................................................................... 15

3. ANALISIS SISMICOS ................................................................................................................ 17

3.1. 3.1 FACTORES PARA EL ANALISIS ............................................................................... 17

3.1.1. FUERZAS SISMICAS VERTICALES ........................................................................ 17

3.2. ANALISIS SISMICO DINAMICO ...................................................................................... 17

3.2.1. ESPECTRO DE PSEUDO ACELERACIONES .......................................................... 17

3.2.2. PERIODOS Y MASA PARTICIPANTE ..................................................................... 20

3.3. ANALISIS SISMICO ESTATICO ....................................................................................... 20

3.3.1. PESO DE LA ESTRUCTURA (P) ............................................................................... 20

4. DISEÑO DE ELEMENTOS DE CONCRETO ARMADO ......................................................... 21

4.1. COMPROBACIÓN DE DISEÑO DE VIGAS V-1 Y V-2 ................................................... 22

4.2. COMPROBACION DE DISEÑO DE COLUMNA A ELIMINAR ..................................... 25

5. ANALISIS DE ESTRUCTURA SIN COLUMNA ...................................................................... 28

5.1. COMPROBACION DE COLUMNAS DE PORTICO......................................................... 30

6. CONTROL DE DESPLAZAMIENTOS LATERALES .............................................................. 32

7. REFERENCIAS BIBLIOGRAFICAS ......................................................................................... 34

Página 2 de 34
MEMORIA DE CALCULO ESTRUCTURAL

1. GENERALIDADES

La presente Memoria corresponde al análisis sísmico y calculo estructural del proyecto


“VIVIENDA MULTIFAMILIAR”, de Propietario “Sr. Saravia Gallegos, Jorge Luciano y Sra. Dongo
de Saravia, Estela Zoraida”; proyectado en una edificación de 5 niveles; con ubicación en Pueblo
Nuevo Mz. U - Lote S35 - Sector B distrito de Pacocha, provincia de Ilo, departamento de Moquegua.

1.1. ESTRUCTURACION

El sistema estructural planteado consiste en el “Dual”, conformado por Placas (Muros de Concreto
Armado), Columnas y Vigas de Concreto Armado para conformar pórticos en ambos sentidos que
contribuyan al aumento de la rigidez lateral del sistema.
Se tienen 5 secciones de columnas estructurales:
 C-1: 0.25x0.40 m.  C-4: 0.15x0.30 m.
 C-2: 0.30x0.50 m.  C-5: 0.30x0.65 m.
 C-3: Diámetro de 0.30 m.
Se tienen 4 secciones de vigas estructurales:
 VB: 0.10x0.20 m.  VP: 0.25x0.40 m.
 VCH: 0.30x0.20 m.  VP: 0.30x0.60 m.
Se tienen 3 secciones de placas:
 PL-01: 1.20x0.25 m.
 PL-02: 1.90x0.25 m.
 PL-03: 0.75x0.25 m.
El diafragma rígido lo conforman Losas aligeradas en un sentido X-X, de peralte 20cm en todos los
niveles, según se indica en los planos.

1.2. NORMAS EMPLEADAS

Se sigue las disposiciones de los Reglamentos y Normas Nacionales e Internacionales descritos a


continuación.
 Reglamento Nacional de Edificaciones (Perú) – Normas Técnicas de Edificación (N.T.E.):
 NTE E.020 “CARGAS”.
 NTE E.060 “CONCRETO ARMADO”.
 NTE E.030 “DISEÑO SISMORRESISTENTE”.
 NTE E.070 “ALBAÑILERIA”.
 NTE E.050 “SUELOS Y CIMENTACIONES”.
 A.C.I. 318 – 2008 (American Concrete Institute) - Building Code Requirements for Structural
Concrete.
Se entiende que todos los Reglamentos y Normas están en vigencia y/o son de la última edición.

1.3. ESPECIFICACIONES – MATERIALES EMPLEADOS

 CONCRETO:
 Resistencia a la compresión: (f´c): 210 Kg/cm2 (todo)
 Módulo de Elasticidad: (E): 15100*sqr(f’c) Kg/cm2 (f´c = 210 Kg/cm2)
 Módulo de Poisson: (u): 0.20
 Peso Específico: (γC): 2300 Kg/m3 (concreto simple); 2400 Kg/m3 (concreto
armado)

Página 3 de 34
MEMORIA DE CALCULO ESTRUCTURAL

 ACERO CORRUGADO (ASTM A-615):


 Resistencia a la fluencia: (fy): 4,200 Kg/cm2 (Gº 60)
 Módulo de Elasticidad: (E): 2’100,000 Kg/cm2
 ALBAÑILERIA TUBULAR:
 Resistencia: (f´m): 65 Kg/cm2
 Módulo de Elasticidad: (E): 32,500 Kg/cm2 (E = 500*f’m)
 Módulo de Poisson: (u): 0.15
 Peso Específico: (γC): 1850 Kg/m3
 RECUBRIMIENTOS MÍNIMOS (R):
 Columnas, Vigas: 4.00 cm
 Losas macizas, Escaleras 2.50 cm

1.4. CARACTERISTICAS DEL TERRENO Y CONSIDERACIONES DE


CIMENTACION

Según especificaciones del proyectista:


 Peso Específico: (γS): 2,000 Kg/m3
 Nivel freático: no encontrado.
 Capacidad portante: (σ´T):1.5 Kg/cm2
 Asentamiento Permisible: (DF): 1.50 cm

Página 4 de 34
MEMORIA DE CALCULO ESTRUCTURAL

1.5. REFERENCIAS

Cimentación de Proyecto de Vivienda Multifamiliar

Página 5 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Primer Nivel de Proyecto de Vivienda Multifamiliar

Página 6 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Segundo Nivel de Proyecto de Vivienda Multifamiliar

Página 7 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Tercer Nivel de Proyecto de Vivienda Multifamiliar

Página 8 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Cuarto Nivel de Proyecto de Vivienda Multifamiliar

Página 9 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Quinto Nivel de Proyecto de Vivienda Multifamiliar

Página 10 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diafragma - Azotea de Proyecto de Vivienda Multifamiliar

Página 11 de 34
MEMORIA DE CALCULO ESTRUCTURAL

ESTRUCTURACION: MODELO DE ANALISIS DEL PRIMER AL QUINTO NIVEL

Página 12 de 34
MEMORIA DE CALCULO ESTRUCTURAL

2. ESTADOS Y COMBINACIONES DE CARGA:

2.1. ESTADOS DE CARGAS

De acuerdo a las Normas NTE. E.020, E060 y al reglamento ACI 318-08, se consideran los
siguientes estados de Carga en la estructura según valores definidos de las normativas anteriormente
descritas, dónde:
 CARGA VIVA 1 Y 2 son dos alternancias consideradas para la carga viva total (L).
 PESO PROPIO es la carga de la misma estructura.
 CARGA MUERTA es la sobrecarga dada por todo aquello que no se movilizara.
 Sismo ex +/- son fuerzas sísmicas en dirección. X-X, con excentricidad accidental de 5% en
dirección “+Y” y “–Y” respectivamente, en cada block y nivel.
 Sismo ey +/- son fuerzas sísmicas en dirección. X-X, con excentricidad accidental de 5% en
dirección. “+Y” y “–Y” respectivamente, en cada block y nivel.

Cargas estáticas usadas en el proyecto de 5 niveles

2.2. COMBINACIONES DE CARGAS

Definiendo primero las combinaciones auxiliares “envL” y “envS”:

Combinación de carga para realizar Envolvente de cargas vivas para


la alternancia de cargas vivas. obtener el caso más cargado.

Página 13 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Envolvente de cargas de sismo para Envolvente de estados de cargas de


obtener el caso más cargado. diseño.

Página 14 de 34
MEMORIA DE CALCULO ESTRUCTURAL

2.3. ALTERNANCIA DE CARGAS

DIAFRAGMA 1° Y 2º NIVEL (Se indican valores de la 1º Y 2º alternancia de la carga viva en kg/m2;


además del Centro de Masa de cada diafragma).

Página 15 de 34
MEMORIA DE CALCULO ESTRUCTURAL

DIAFRAGMA 3° Y 4º NIVEL (Se indican valores de la 1º Y 2º alternancia de la carga viva en kg/m2;


además del Centro de Masa de cada diafragma).

Página 16 de 34
MEMORIA DE CALCULO ESTRUCTURAL

3. ANALISIS SISMICOS

3.1. 3.1 FACTORES PARA EL ANALISIS

El Análisis Sísmico se realiza utilizando un modelo matemático tridimensional en donde los


elementos verticales están conectados con diafragmas horizontales, los cuales se suponen infinitamente
rígidos en sus planos. Además, para cada dirección, se ha considerado una excentricidad accidental de
0.05 veces la dimensión del edificio en la dirección perpendicular a la acción de la fuerza. Los
parámetros sísmicos que estipula la Norma de Diseño Sismorresistente (NTE E.030) considerados para
el Análisis en el Edificio son los siguientes:

Clasificación
Factor Nomenclatura Valor Justificación
Categórica Tipo
Zona Z 4 0.45 Zona Sísmica 3: Lima
Edificaciones Comunes:
Uso U C 1.0
Viviendas
S 1.05 Grava Mal graduada
Suelo 2
Tp (s) 0.4 (de E.M.S.)
Porticos de CºAº y Muros
Rx Dual 5.25
(irregular)
Coeficiente de
Muros de
reducción Albañilería
Ry 2.25 Albañilería confinada
Confinada
(irregular)

3.1.1. FUERZAS SISMICAS VERTICALES

El factor de Zona de la Edificación clasifica como “Z1”. Por tanto, según la NTE - E.030, las fuerzas
sísmicas verticales se considerarán como una fracción de 2/3 del valor de la fuerza sísmica horizontal

3.2. ANALISIS SISMICO DINAMICO

3.2.1. ESPECTRO DE PSEUDO ACELERACIONES

Para el Análisis Dinámico de la Estructura se utiliza un Espectro de respuesta según la NTE - E.030,
para comparar la fuerza cortante mínima en la base y compararlos con los resultados de un análisis
estático. Todo esto para cada dirección de la Edificación en planta (X e Y).

Región : Moquegua
Provincia : Ilo
Distrito : Pacocha
Categoría : C Z = 0.45
Zona : Z4 U = 1.00
Suelo : S2 S = 1.05
Sistema Estructural : Concreto Armado, Dual Tp = 0.60
Verificación de Irregular en Planta Ip = 0.7500 TL = 2.00
Irregularidad : Irregular en Altura Ia = 1.0000 R o = 7.0
R = 5.25

Página 17 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Espectro de Pseudo Aceleraciones

Espectro de Pseudo Aceleraciones de Diseño NTE E-030

Página 18 de 34
MEMORIA DE CALCULO ESTRUCTURAL

T C ZUCS/R
0 2.5 0.225
0.02 2.5 0.225
0.04 2.5 0.225
0.06 2.5 0.225
0.08 2.5 0.225
0.1 2.5 0.225
0.12 2.5 0.225
0.14 2.5 0.225
0.16 2.5 0.225
0.18 2.5 0.225
0.2 2.5 0.225
0.25 2.5 0.225
0.3 2.5 0.225
0.35 2.5 0.225
0.4 2.5 0.225
0.45 2.5 0.225
0.5 2.5 0.225
0.55 2.5 0.225
0.6 2.5 0.225
0.65 2.307692 0.20769231
0.7 2.142857 0.19285714
0.75 2 0.18
0.8 1.875 0.16875
0.85 1.764706 0.15882353
0.9 1.666667 0.15
0.95 1.578947 0.14210526
1 1.5 0.135
1.6 0.9375 0.084375
2 0.75 0.0675
2.5 0.48 0.0432
3 0.333333 0.03
4 0.1875 0.016875
5 0.12 0.0108
6 0.083333 0.0075
7 0.061224 0.0055102
8 0.046875 0.00421875
9 0.037037 0.00333333
10 0.03 0.0027

Página 19 de 34
MEMORIA DE CALCULO ESTRUCTURAL

3.2.2. PERIODOS Y MASA PARTICIPANTE

Los periodos y la masa participante calculados mediante un análisis dinámico para 12 modos de
vibración (3 modos por cada nivel), se presentan a continuación:

TABLE: Modal Periods and Frequencies


Case Mode Period Frequency Circular Frequency Eigenvalue
sec cyc/sec rad/sec rad²/sec²
Modal 1 0.762 1.313 8.2498 68.06
Modal 2 0.526 1.903 11.9551 142.924
Modal 3 0.486 2.058 12.9287 167.1501
Modal 4 0.221 4.517 28.3797 805.4095
Modal 5 0.156 6.402 40.2256 1618.0978
Modal 6 0.132 7.583 47.6465 2270.1912
Modal 7 0.101 9.905 62.2367 3873.404
Modal 8 0.072 13.821 86.8402 7541.22
Modal 9 0.069 14.4 90.4789 8186.4322
Modal 10 0.056 17.783 111.7361 12484.9469
Modal 11 0.053 18.767 117.9142 13903.7469
Modal 12 0.038 26.553 166.8376 27834.7929

Periodos y frecuencias del proyecto de 5 niveles

TABLE: Modal Participating Mass Ratios


Case Mode Period UX UY UZ Sum UX Sum UY Sum UZ
sec
Modal 1 0.762 0.004 0.7712 0 0.004 0.7712 0
Modal 2 0.526 0.1718 0.0635 0 0.1758 0.8347 0
Modal 3 0.486 0.6582 0.0042 0 0.8341 0.8389 0
Modal 4 0.221 0.0003 0.0923 0 0.8344 0.9312 0
Modal 5 0.156 0.0211 0.0148 0 0.8554 0.946 0
Modal 6 0.132 0.0933 0.0012 0 0.9487 0.9472 0
Modal 7 0.101 0.0001 0.0269 0 0.9488 0.9742 0
Modal 8 0.072 0.0032 0.0029 0 0.952 0.977 0
Modal 9 0.069 0.0032 0.0036 0 0.9552 0.9806 0
Modal 10 0.056 0.0277 0.0004 0 0.9829 0.9809 0
Modal 11 0.053 0.0003 0.0098 0 0.9832 0.9907 0
Modal 12 0.038 0.003 0.0032 0 0.9862 0.9939 0

Masas Participantes por cada modo de vibración

3.3. ANALISIS SISMICO ESTATICO


Se calculará el Cortante Estático con los valores de los parámetros definidos anteriormente, además
de definir el Peso de la Estructura y el Factor de Ampliación Dinámica (C).

3.3.1. PESO DE LA ESTRUCTURA (P)


La estructura clasifico como categoría C, por lo tanto, el peso que se ha considerado para el análisis
sísmico es el debido a la carga permanente más el 25% de la carga viva (100%CM + 25%CV). En
azoteas y techo en general se considera el 25% de la carga viva (100%CM + 25%CV).

Página 20 de 34
MEMORIA DE CALCULO ESTRUCTURAL

CARGA MUERTA: El valor de las Cargas Muertas empleadas comprende el peso propio de los
elementos estructurales (losas, vigas, columnas, placas, muros, etc.) según características descritas en el
Ítem 1.3; además del peso de los elementos aligeradores en losas, el peso de la tabiquería y el peso de
los acabados.
CARGA VIVA: El valor de Carga Viva empleada es de 200 kg/m2 del 1° al 3° nivel (viviendas), 200
kg/m2 (corredores y escaleras), y 100 kg/m2 en azotea.

TABLE: Centers of Mass and Rigidity


Story Diaphragm Mass X Mass Y XCM YCM Cumulative X Cumulative Y XCCM YCCM
kg kg m m kg kg m m
PISO 5 D1 141789.93 141789.93 6.1605 8.3919 141789.93 141789.93 6.1605 8.3919
PISO 4 D1 148091.88 148091.88 6.0219 8.7827 289881.8 289881.8 6.0897 8.5915
PISO 3 D1 157966.28 157966.28 6.2111 8.3483 447848.08 447848.08 6.1325 8.5057
PISO 2 D1 162244.03 162244.03 6.1138 8.1769 610092.1 610092.1 6.1275 8.4183
PISO 1 D1 177706.23 177706.23 6.1847 8.7622 787798.33 787798.33 6.1404 8.4959

Centros de Masa y Rigidez (Peso de la estructura)

4. DISEÑO DE ELEMENTOS DE CONCRETO ARMADO

Se verificará la problemática de haber colocado la columna en el proyecto. Se procederá a comparar


los resultados obtenidos en el análisis de cargas, para evaluar si la estructura soportara la eliminación de
esa columna.

Columna que se eliminara del proyecto de 5 niveles

Se verificará la problemática de haber colocado la columna en el proyecto. Se procederá a comparar los


resultados obtenidos en el análisis de cargas (envolvente), para evaluar si la estructura soportara la
eliminación de esa columna.

Posteriormente se volverá a analizar la estructura, pero sin la columna a eliminar, para verificar que los
esfuerzos en la estructura no provocaran una modificación en el proyecto.

Página 21 de 34
MEMORIA DE CALCULO ESTRUCTURAL

4.1. COMPROBACIÓN DE DISEÑO DE VIGAS V-1 Y V-2

V-1 V-2

Momentos actuando en las vigas del Eje 2-2

Verificaremos todas las secciones involucradas en la eliminación de la columna del proyecto. La


columna implicada es la C-2, se observa que esta columna esta estructural y tiene un refuerzo de 8
varillas de 5/8”.

Secciones de columnas y placas del proyecto de 5 niveles

Página 22 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Secciones de vigas del proyecto de 5 niveles

A continuación, observaremos los diagramas de fuerzas cortantes y momentos flectores de los cuales
usaremos los datos más críticos para la verificación de refuerzo de acero dada en las vigas de la columna.

Diagramas de fuerzas Cortantes y Momentos flectores en viga VP (0.30x0.60) - V-1

Página 23 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diagramas de fuerzas Cortantes y Momentos flectores en viga VP (0.30x0.60) - V-2

Calculo rápido de acero de refuerzo en viga VP (0.30x0.60) – V-1

Se observa que el acero de refuerzo necesario es mucho menor al indicado en el proyecto, por eso se
concluye que la viga V-1 tiene un sobre refuerzo de acero; observamos que el momento flector actuante
máximo es de -10.15 Tn-m, y la viga en con esa sección puede soportar un momento flector máximo de
33.43 Tn-m. La resistencia a la viga se debe a la sobredimensión de esta, al tener un peralte elevado (60
cm) esta no requiere de mucho refuerzo de acero.

Verificando la misma situación en la viga V-2, comprobamos que esta también presenta un sobre
refuerzo de acero; observamos que el momento flector actuante máximo es de -7.25 Tn-m, y la viga en

Página 24 de 34
MEMORIA DE CALCULO ESTRUCTURAL

con esa sección puede soportar un momento flector máximo de 33.43 Tn-m. La resistencia a la viga se
debe a su sobredimensión, al tener un peralte elevado (60 cm) no requiere de mucho refuerzo de acero.

Calculo rápido de acero de refuerzo en viga VP (0.30x0.60) – V-2

4.2. COMPROBACION DE DISEÑO DE COLUMNA A ELIMINAR

Diagrama de Momentos Actuantes en dirección 3-3 en Columna a eliminar C-2 (0.30x0.50)

Página 25 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diagrama de Momentos Actuantes en dirección 2-2 en Columna a eliminar C-2 (0.30x0.50)

Diagrama de Fuerzas Axiales en Columna a eliminar C-2 (0.30x0.50)

Verificando si la columna a eliminar tiene el refuerzo necesario observamos que su diagrama de


interacción nos da una holgura de aguantar tanto Momentos flectores como Fuerzas Axiales.

Se procedió a realizar el Diagrama de Interacción con un solo punto de verificación y este demostró
buenos resultados resistiendo esfuerzos unidireccionales y bidireccionales.

Página 26 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Calculo rápido verificación de acero de refuerzo en Columna a eliminar C-2 (0.30x0.50)

Diagrama de Interacción en Columna a eliminar C-2 (0.30x0.50)

Página 27 de 34
MEMORIA DE CALCULO ESTRUCTURAL

5. ANALISIS DE ESTRUCTURA SIN COLUMNA

Se verificará los diagramas de fuerzas cortantes y momentos flectores sin la columna no proyectada.
Procederemos a revisar que los esfuerzos no superen el refuerzo de acero puesto ahora en la nueva viga
de 5.25 m de luz, dado que ahora la columna no existe, se amplifican las cargas en esta viga.
Dependiendo de los resultados obtenidos se procederá a dar una conclusión de reforzar o no.

Momentos actuando en la viga sin la columna proyectada

Diagramas de fuerzas Cortantes y Momentos flectores en viga VP (0.30x0.60) de 5.25 m de luz

Página 28 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Calculo rápido de acero de refuerzo en viga VP (0.30x0.60)

Se observa que el acero de refuerzo necesario es mucho menor al indicado en el proyecto, por eso se
concluye que la viga VP (0.30x0.60) tiene un sobre refuerzo de acero; observamos que el momento
flector actuante máximo es de -10.79 Tn-m, y la viga en con esa sección puede soportar un momento
flector máximo de 37.74 Tn-m. La resistencia a la viga se debe a la sobredimensión de esta, al tener un
peralte elevado (60 cm) esta no requiere de mucho refuerzo de acero.

Página 29 de 34
MEMORIA DE CALCULO ESTRUCTURAL

5.1. COMPROBACION DE COLUMNAS DE PORTICO

Verificando si la columna a eliminar tiene el refuerzo necesario observamos que su diagrama de


interacción nos da una holgura de aguantar tanto Momentos flectores como Fuerzas Axiales. Se procedió
a realizar el Diagrama de Interacción con un solo punto de verificación y este demostró buenos
resultados resistiendo esfuerzos unidireccionales y bidireccionales.

Diagrama de Momentos Actuantes en dirección 3-3 en Columna a eliminar C-2 (0.30x0.50)

Diagrama de Momentos Actuantes en dirección 2-2 en Columna a eliminar C-2 (0.30x0.50)

Página 30 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diagrama de Fuerzas Axiales en Columna a eliminar C-2 (0.30x0.50)

Calculo rápido verificación de acero de refuerzo en Columna a eliminar C-2 (0.30x0.50)

Página 31 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Diagrama de Interacción en Columna a eliminar C-2 (0.30x0.50)

6. CONTROL DE DESPLAZAMIENTOS LATERALES

De acuerdo a la Norma NTE. E030, para el control de los desplazamientos laterales, los resultados
deberán ser multiplicados por el valor de 0.75R para calcular los máximos desplazamientos laterales de
la estructura. Se tomaron los desplazamientos del centro de masa y del eje más alejado.

Los resultados se muestran en la siguiente tabla para cada dirección de análisis.


Dónde:
 Δi/he = Desplazamiento relativo de entrepiso

Además:
 ΔiX/heX (máx.) = 0.0070 (máximo permisible Concreto armado, NTE E.030 – 3.8).
 ΔiY/heY (máx.) = 0.0050 (máximo permisible Albañilería confinada, NTE E.030 – 3.8).

Se observa que, tanto en el Eje del Centro de Masa como en los Ejes más alejados de este en cada
dirección, todos los entrepisos cumplen con el Desplazamiento relativo máximo permisible de entrepiso
(Δi/he) MAX en ambas direcciones.

Página 32 de 34
MEMORIA DE CALCULO ESTRUCTURAL

Desplazamientos de Diafragmas por niveles (Máximos y Mínimos).

Página 33 de 34
MEMORIA DE CALCULO ESTRUCTURAL

7. REFERENCIAS BIBLIOGRAFICAS

Página 34 de 34

You might also like