Professional Documents
Culture Documents
NTPC Limited
CONTENTS
Sl Page
Description
No. No.
I. Boiler & Auxiliaries
1.0 CONTRACT DATA OF BOILER 7
1.1 FUEL FIRING EQUIPMENTS 7
1.2 BOILER 7
1.3 BOILER AUXILIARIES 8
1.4 SOOT BLOWER AND TEMP PROBE 8
1.5 PIPE LINES 8
1.6 BOILER MOUNTING 8
1.7 DUST COLLECTOR 9
1.8 MAIN PARAMETERS 9
2.0 PREDICTED PERFORMANCE 10
2.1 DESIGN COAL - CONSTANT PRESSURE : TOP MILLS 10
2.2 DESIGN COAL - CONSTANT PRESSURE - BOTTOM MILLS 14
2.3 WORST COAL - CONSTANT PRESSURE – TOP MILLS 18
2.4 WORST COAL - CONSTANT PRESSURE – BOTTOM MILLS 22
2.5 BEST COAL-CONSTANT PRESSURE – TOP MILLS 26
2.6 BEST COAL-CONSTANT PRESSURE – BOTTOMMILLS 30
2.7 DESIGN COAL - SLIDING PRESSURE OPERATION 24
2.8 WORST COAL-SLIDING PRESSURE OPERATION 38
2.9 BEST COAL-SLIDING PRESSURE OPERATION 42
3.0 BOILER EFFICIENCY CALCULATION 47
4.00 BOILER AUXILIARIES 47
4.1 APH 47
4.2 APH LUB. OIL SYSTEM 49
4.3 ID FAN 50
4.4 I D FAN MOTOR 50
4.5 ID FAN LUB. OIL SYSTEM 53
4.6 FD FAN 54
4.7 F D FAN MOTOR 54
4.8 FD FAN LUB. OIL SYSTEM 56
4.9 PA FAN 57
4.10 PA FAN MOTOR 57
4.11 PA FAN LUB. OIL SYSTEM 59
4.12 SEAL AIR FAN 60
4.13 SCANNER AIR FAN 60
4.14 RENT HOUSE VENTILATION FAN 61
5.00 FUEL FIRING SYSTEM 62
5.1 MILL 62
5.2 MILL MOTOR 62
5.3 MILL LUB. OIL SYSTEM 64
5.4 MILL REJECT STORAGE BUNKER 65
5.5 DENSEVEYOR 65
5. 6 AIR COMPRESSURE FOR MILL REJECT 66
5.7 OIL FIRING 67
5.8 HFO SPECIFICATION 67
5.9 LDO SPECIFICATION 67
5.10 HFO HEATER 68
5.11 HFO COOLER 68
5.12 LFO PUMP MOTOR 68
5.13 HFO PUMP MOTOR 69
5.14 DRAIN OIL PUMP 69
5.15 HFO PUMP 71
5.16 LDO PUMP 72
6.00 ESP 74
7.00 SOOT BLOWER 76
7.1 SOOT BLOWER MOTOR 76
8.00 HP DOSSING SYSTEM 77
8.1 HP DOSSING METERING PUMP 77
8.2 HP DOSSING METERING PUMP MOTOR 78
9.00 SAFETY VALVE 78
II. Turbine & Auxiliaries
10.00 TURBINE AND AUXIALIERIES 80
10.1 TURBINE SPECIFICATION 80
11.0 TURBINE OIL SYSTEM 83
11.1 TURBINE LUB. OIL SYSTEM 83
11.2 TURBINE OIL PUMP 83
11.3 PROPERTIES OF TURBINE OIL 83
11.4 LIMITS OF TURBINE OIL PROPERTIES 84
11.5 TURBINE OIL BRANDS 84
11.6 AUXILIARY OIL PUMP 84
11.7 AOP MOTOR 85
11.8 JACKING OIL PUMP (AC/DC) 86
11.9 MOTOR OF AC JOP 86
11.10 MOTOR OF DC JOP 87
11.11 EMERGENCY OIL PUMP 88
11.12 MOTOR OF EMERGENCY OIL PUMP 88
11.13 MOT CENTRIFUGE MACHINE 89
11.14 LUB. OIL COOLER 90
12.00 DEARATOR 91
13.00 BOILER FEED PUMP 91
13.1 BFP BOOSTER PUMP 91
13.2 BFP MAIN PUMP 92
13.3 BFP HYDRAULIC COUPLING 92
13.4 BFP GENERAL DATA SHEET 92
13.5 BFP MOTOR 97
14.00 HPH 100
14.1 HPH-5 100
14.2 HPH-6 100
15.00 CONDENSER 101
16.00 LP HEATER 102
17.00 CEP 102
17.1 CEP 102
17.2 CEP MOTOR 104
18.00 MAIN VAC PUMP 107
18.1 MAIN VAC PUMP 107
18.2 MAIN VAC PUMP MOTOR 107
19.00 EQUIPMENTS COOLING WATER REQUIREMENT 109
20.00 PLATE HEAT EXCHANGER 110
21.00 ECW PUMP 110
21.1 ECW PUMP 112
21.2 ECW PUMP MOTOR 113
22.00 ACW PUMP 116
22.1 ACW PUMP 116
22.2 ACW PUMP MOTOR 118
23.00 SELF CLEANING STRAINERS 120
24.00 ON LINE CONDENSER TUBE CLEANING SYSTEM 125
24.1 LUBRICATION OF ONLIE TUBE CLEANING SYSTEM 135
25.00 LP DOSING SYSTEM 136
25.1 LP DOSING EQUIPMENTS 136
25.2 LP DOSING METERING PUMPS 139
26.00 SODIUM HYDROXIDE DOSING SYSTEM 140
27.0 RECOMMENDED VALUES FOR MAIN STEAM AND CONDENSATE 141
III. GENERATOR
28.00 GENERATOR 143
28.1 GENERAL 143
28.2 GENERATOR 144
28.3 EXCILATION SYSTEM 147
28.4 GENERATOR GAS SYSTEM 149
28.5 GENERATOR SEAL OIL SYSTEM 150
28.6 HYDROGEN COOLER BOOSTER PUMP 151
IV. TRANSFORMERS AND AUXILIARIES
29.00 TRANSFORMERS 153
29.1 GENERATOR TRANSFORMER 153
29.2 UNIT AUXILIARY TRANSFORMER 156
29.3 UST & SST (2000 KVA ) 160
29.4 1600 KVA LT TRANSFORMERS 162
29.5 100 KVA LT TRANSFORMERS 164
29.6 250 KVA LT TRANSFORMERS 166
29.7 70 KVP / 1200 MA HVR TRANSFORMERS 168
29.8 220 VOLT BATTERY CHARGER 170
29.8.1 DC NI- CD BATTERY 170
29.8.2 220 V DC BATTERY CHARGER 170
V. OFFSITE
30.00 CW PUMP 178
30.1 CW PUMP 178
30.2 CW PUMP MOTOR 180
31.00 AIR COMPRESSOR 183
31.1 AIR COMPRESSOR 183
31.2 AIR COMPRESSOR MOTOR 185
31.3 AIR DRYER 187
31.4 BLOWER 188
32.00 AIR CONDITIONING SYSTEM 189
32.1 AC PLANT CAPACITY 189
32.2 AC AHU CAPACITY - MAIN CONTROL ROOM 189
32.3 DESIGN CRITERIA - MAIN CONTROL ROOM 189
32.04 AC AHU CAPACITY - ESP &VED CONTROL ROOM 190
32.05 DESIGN CRITERIA - ESP & VFD CONTROL ROOM 190
32.06 AC AHU CAPACITY SERVICE BUILDING 190
32.07 CONDENSATE WATER PUMP 191
32.08 CHILLED WATER PUMP 197
32.09 HVAC WATER PUMP 192
32.10 SOFT WATER PUMP 193
32.11 AHU FOR MAIN CONTROL ROOM 193
32.12 AHU FOR ESP VFD CONTROL ROOM 193
32.13 AHU FOR SERVICE BUILDING 194
32.14 AC CAPACITY PLC ROOM 194
32.15 AXIAL FLOW FAN -MAIN CONTROL ROOM 195
32.16 AXIAL FLOW FAN - SERVICE BUILDING (FF) 196
32.17 AXIAL FLOW FAN - SERVICE BUILDING (SF ) 196
32.18 SPLIT AC CONDITIONS (I) 197
32.19 SPLIT AC CONDITIONS (II) 198
32.20 AIR FILTER 198
32.21 CASSETTE TYPS PRE FILTER 199
32.22 CASETTE TYPS FINE FILTER 199
32.23 VAPOUR ABSORBTION MACHINE 200
32.24 SCREW CHILLER 201
33.00 VENTILATION SYSTEM 202
33.01 UNITARY AIR FILTERATION UNIT 202
33.02 VENTILATION PUMP 203
SECTION - I
BOILER
&
AUXILIARIES
1.0 CONTRACT DATA OF BOILER
Proposed fuel : Coal
Proximate Analysis : Fixed Carbon 25.00 %
Volatile Material 22.00 %
H 2O 13.00 %
Ash 40.00 %
HHV 3400 Kcal/Kg.
Grindability (HGI ) 55
Mills
Type Bowl mill XRP 883
Make & Nos. BHEL, -6
Capacity 45.9 ton / hrs
Motor Power 425 KW,600 RPM
System Pressurised
Furnace
Type Balanced draft Type Fusion welded walls
3
Width 13868 mm Volume 5561 m
6
Depth 10592 mm Fuel heat input (Max) 520.9x10 K cal/hr
1.2 BOILER
Boiler Natural circulation, radiant reheat outdoor
Designation 13868 181-63.5 1778 - NCRR
10592 130-63.5
Design pressure 179.0 Kg/cm² (g)
Super heater outlet pressure 156.0 Kg/cm² (g)
Super heater
Total heating surface installed area 7397 m²
Stage-I : Low temp super heater 4757 m²
Stage-II : Platen super heater 1097 m² (projected)
Stage-III : Spaced final super heater 1543 m²
Attemperator
Type Spray
no. of stages 01
Medium of spray Feed water
Reheater
Type Spaced
Total heating surface area 3553 m²
Control Burner tilt, excess air
Economiser
Type Plane tube
Total heating surface area 6100 m²
No. of blocks 02
Air Heater
Type Rotary, regenerative, trisector, 27.5VMT 2000
Total heating surface area (Each) 36126 m²
Nos. 02
Motor power 11 KW
Make BHEL
FUELDESIGN COAL
60% BOTH
UNIT BMCR TMCR
TMCR HPH OUT
GENERATOR MW - 210 126 TMCR
STEAM - FLOW
SUERHEAT T/h 680 627.7 382.4 595.4
REHEAT T/h 590.7 563.1 348.5 586.9
TOTAL HEAT TO BOILER (HEAT FIRED) Mkcal/h 520.5 482.8 306.9 516.2
PRESSURE AT SUPERHEATER OUTLET Kg/cm (g) 156.0 155 151.3 154.4
TEMPERATURE AT SUPERHEATER C 540 540 540 540
INLET
PRESSURE AT REHEATER INLET Kg/cm (g) 38.98 37.29 22.81 39.35
TEMPERATURE AT REHEATER INLET C 343 345 333 352
PRESSURE AT REHEATER OUTLET Kg/cm (g) 37.24 35.64 21.8 37.63
TEMPERATURE AT REHEATER OUTLET C 540 540 540 540
FEED WATER TEMPERATURE C 246 245 222 167
AMBIENT AIR TEMPERATURE C C 27 27 27
COMBUSTION AIR TEMEPERATURE C 308 305 273 267
SECONDARY
FUEL QUANTITY T/h 153.2 141.9 90.5 151.6
AIR QUANTITY (TOTAL) T/h 847 785 501 840
FLUE GAS
TEMP. OF GAS AT ECO INLET C 475 468 432 474
TEMP. OF GAS AT AH INLET C 333 328 291 288
TEMP.OF GAS AT AH C 125 125 121 113
OUTLET(CORRECTED)
EFFICIENCY BASED ON HHV(predicted) % 85.72 85.69 85.70 86.36
2.0 PREDICTED PERFORMANCE
I. FLOW.
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Super heater outlet 680 627.7 504.3 382.4 329.2 595.4
Reheater outlet 590.67 563.1 455.7 348.5 301.8 586.9
Water
Feed water 680 627.7 504.3 382.4 329.2 595.4
SH spray - 9.6 20.5 28 31 28.1
RH spray 2.17 - - - - 1.73
Air
Primary AH Outlet 244 239 187 172 122 241
Tempering air 31 29 21 21 17 35
Second. A.H. Outlet 487 432 350 223 213 479
Total Combustion Air 847 785 643 501 437 840
Gas
RAPH inlet 938 869 711 554 483 930
RAPH outlet 1025 954 792 632 559 1016
Coal
Coal 153.2 141.9 116.2 90.5 78.9 151.6
(HHV=3400 kcal/kg)
II. TEMPERATURE
HP Heaters in HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 353 354 356 353
LTSH outlet 403 404 406 409 411 418
Platen SH inlet 403 398 388 376 369 392
Platen SH outlet 507 508 511 515 516 503
Final SH inlet 507 508 511 515 516 503
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 352
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 294 293 286 278 274 248
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 304 301 289 272 264 263
Second .AH Outlet 308 305 292 273 264 267
Gas
SH Platen inlet 1145 1142 1120 1094 1084 1120
RH Front inlet 1001 990 995 912 891 979
RH Rear inlet 851 837 798 751 726 836
Final SH inlet 750 736 700 658 638 739
LTSH inlet 639 627 598 566 550 632
Economiser inlet 475 468 450 432 424 474
Air heater inlet 333 328 311 291 282 288
Air heater outlet (Corr) 125 125 120 121 120 113
III. PRESSURES (steam& water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
I. FLOW.
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Super heater outlet 680 627.7 504.3 382.4 329.2 595.4
Reheater outlet 590.67 563.1 455.7 348.5 301.8 585.2
Water
Feed water 680 627.7 504.3 382.4 329.2 595.4
SH spray - 9.9 20.9 28.5 28.2 22
RH spray 2.17 - - - - -
Air
Primary AH Outlet 244 239 187 171 121 241
Tempering air 31 29 21 21 19 34
Second. A.H. Outlet 487 432 350 224 254 477
Total Combustion Air 847 785 643 501 479 837
Flue Gas
RAPH inlet 937 869 711 554 526 926
RAPH outlet 1024 954 792 632 603 1012
Fuel
Coal
153.1 141.9 116.2 90.5 79.1 151.2
(HHV=3400 kcal/kg)
II. TEMPERATURE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 353 354 356 353
LTSH outlet 403 404 406 409 411 418
Platen SH inlet 403 398 388 376 369 392
Platen SH outlet 507 508 511 515 516 503
Final SH inlet 507 508 511 515 516 503
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 352
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 294 293 286 278 274 248
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 304 301 289 272 264 263
Second .AH Outlet 308 305 292 273 264 267
Gas
SH Platen inlet 1145 1142 1120 1094 1084 1120
RH Front inlet 1001 990 995 912 891 979
RH Rear inlet 851 837 798 751 726 836
Final SH inlet 750 736 700 658 638 739
LTSH inlet 639 627 598 566 550 632
Economiser inlet 475 468 450 432 424 474
Air heater inlet 333 328 311 291 282 288
Air heater outlet (Corr) 125 125 120 121 120 113
III. PRESSURES (steam& water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
II. TEMPERATURE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 353 354 356 353
LTSH outlet 404 405 407 410 412 418
Platen SH inlet 404 398 389 377 370 393
Platen SH outlet 507 508 510 515 516 504
Final SH inlet 507 508 510 515 516 504
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 353
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 294 294 286 278 274 248
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 306 302 289 273 264 264
Second .AH Outlet 310 306 292 274 264 268
Gas
SH Platen inlet 1142 1139 1116 1093 1081 1115
RH Front inlet 1000 988 953 911 889 976
RH Rear inlet 851 837 797 750 726 834
Final SH inlet 750 736 700 658 638 738
LTSH inlet 639 627 599 566 550 632
Economiser inlet 475 468 451 432 425 474
Air heater inlet 333 328 311 292 282 288
Air heater outlet (Corr) 126 126 122 123 124 115
III. PRESSURES (steam& water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
I.FLOW.
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Super heater outlet 680 627.7 504.3 382.4 329.2 595.4
Reheater outlet 590.67 563.1 455.7 348.5 301.8 585.2
Water
Feed water 680 627.7 504.3 382.4 329.2 595.4
SH spray - 9-9 20.8 28.3 29 22
RH spray 2.17 - - - - -
Air
Primary AH Outlet 301 259 247 183 174 307
Tempering air 45 32 26 23 24 38
Second. A.H. Outlet 417 409 285 210 180 408
Total Combustion Air 848 785 643 501 463 838
Flue Gas
RAPH inlet 943 872 715 556 512 931
RAPH outlet 1030 957 796 634 588 1017
Fuel
Coal
174.1 161.1 132.0 102.7 89.9 171.9
(HHV=3000 kcal/kg)
II. TEMPERATURE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 354 355 356 353
LTSH outlet 404 405 407 411 415 416
Platen SH inlet 404 398 389 377 374 395
Platen SH outlet 506 508 511 515 516 504
Final SH inlet 506 508 511 515 516 504
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 355
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 294 294 286 278 277 247
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 306 302 289 273 267 263
Second .AH Outlet 310 306 292 274 267 267
Gas
SH Platen inlet 1142 1139 1117 1092 1059 1105
RH Front inlet 1000 988 954 911 883 969
RH Rear inlet 851 837 798 750 728 829
Final SH inlet 750 736 700 658 642 734
LTSH inlet 639 628 599 566 555 630
Economiser inlet 475 468 451 433 429 473
Air heater inlet 333 328 311 292 285 287
Air heater outlet (Corr) 126 126 122 123 122 114
III. PRESSURES (steam& water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
X. HEAT BALANCE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Losses
(As per BS 2885)
Dry gas 4.237 4.260 4.153 4.309 4.544 3.765
H2O in fuel, surf, & inherent 3.133 3.133 3.124 3.126 3.124 3.108
H2O from comb. Of H2 4.549 4.549 4.536 4.539 4.536 4.513
H2O in air 0.104 0.105 0.102 0.106 0.112 0.093
Radiation 0.100 0.108 0.131 0.167 0.190 0.102
Unburnt Carbon 1.500 1.500 1.500 1.500 1.500 1.500
Unaccounted 1.066 1.063 1.056 1.065 1.063 1.034
Manufacturer’s margin 0.200 0.200 0.200 0.200 0.200 0.200
Total losses 14.889 14.918 14.802 15.0133 15.269 14.316
Heat credits 0.475 0.449 0.473 0.482 0.513 0.469
Efficiency 85.59 85.53 85.67 85.47 85.24 86.15
2.5 Best Coal-Constant Pressure – Top Mills
I. FLOW.
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Super heater outlet 680 627.7 504.3 382.4 329.2 595.4
Reheater outlet 590.7 563.1 455.7 348.5 301.8 586.1
Water
Feed water 680 627.7 504.3 382.4 329.2 595.4
SH spray -- 10.9 22 29.7 33 26.2
RH spray 2.17 -- -- -- 0.94
Air
Primary AH Outlet 192 181 155s 139 111 225
Tempering air 62 67 36 42 18 31
Second. A.H. Outlet 493 440 355 255 212 480
Total Combustion Air 832 773 631 491 426 821
Flue Gas
RAPH inlet 910 845 690 537 466 898
RAPH outlet 993 927 768 613 541 984
Fuel
Coal
12.0 118.9 97.1 75.5 65.6 126.2
(HHV=3000 kcal/kg)
II. TEMPERATURE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 354 355 356 354
LTSH outlet 402 404 406 409 411 415
Platen SH inlet 402 396 386 374 367 392
Platen SH outlet 507 508 511 515 516 504
Final SH inlet 507 508 511 515 516 504
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 353
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 293 292 285 276 273 246
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 304 303 288 270 262 259
Second .AH Outlet 308 306 290 271 263 263
Gas
SH Platen inlet 1165 1162 1140 1115 1108 1136
RH Front inlet 1016 1004 968 925 904 990
RH Rear inlet 861 846 806 757 733 843
Final SH inlet 756 741 705 662 641 743
LTSH inlet 642 630 600 567 551 633
Economiser inlet 475 468 450 432 424 473
Air heater inlet 330 326 309 289 280 284
Air heater outlet (Corr) 130 132 124 127 120 110
III. PRESSURES (steam & water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
II. TEMPERATURE
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Steam
Sat. temp. in Drum 350 348 346 343 343 348
LTSH inlet 354 354 354 355 355 354
LTSH outlet 403 404 406 412 415 414
Platen SH inlet 403 396 386 377 377 393
Platen SH outlet 507 508 511 514 516 505
Final SH inlet 507 508 511 514 516 505
Final SH outlet 540 540 540 540 540 540
RH inlet 343 345 339 333 330 355
RH outlet 540 540 540 540 540 540
Water
Economiser inlet 246 245 235 222 216 167
Economiser outlet 293 292 284 278 278 245
Air
Ambient 27 27 27 27 27 27
Primary AH Outlet 306 303 288 272 266 260
Second .AH Outlet 309 306 290 273 267 263
Gas
SH Platen inlet 1165 1162 1142 1101 1053 1130
RH Front inlet 1016 1004 969 920 886 985
RH Rear inlet 861 846 806 759 734 839
Final SH inlet 756 741 705 665 647 740
LTSH inlet 642 630 600 571 560 632
Economiser inlet 475 468 450 435 431 472
Air heater inlet 331 326 309 291 285 284
Air heater outlet (Corr) 130 132 124 126 117 110
III. PRESSURES (steam & water)
HP Heaters in service HPH out
Description 100% 100% 80% 60% 50% Max Heat
BMCR TMCR TMCR TMCR TMCR Input
Pressure
Super Heater outlet 156.0 155.0 153.0 151.3 150.7 154.4
LTSH Outlet 163.6 161.6 157.4 153.9 152.7 160.3
Drum 167.9 165.3 159.8 155.4 153.8 163.6
Economiser inlet 173.1 170.0 163.7 158.6 156.7 168.1
Reheater inlet 38.98 37.29 30.05 22.81 19.66 39.35
Reheater outlet 37.24 35.64 28.72 21.80 18.77 37.63
Pressure Drop
Super heater system 11.9 10.3 6.8 4.1 3.1 9.2
Reheater system 1.74 1.65 1.33 1.01 0.89 1.72
Economiser (Friction only) 3.1 2.7 1.8 1.1 0.8 2.4
II. TEMPERATURE
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Steam
Sat. temp. in Drum 345 327 307 297
LTSH inlet 350 339 326 320
LTSH outlet 405 409 411 412
Platen SH inlet 396 381 360 347
Platen SH outlet 508 510 515 516
Final SH inlet 508 510 515 516
Final SH outlet 540 540 540 540
RH inlet 348 351 354 355
RH outlet 540 540 540 540
Water
Economiser inlet 245 235 222 216
Economiser outlet 293 283 273 269
Air
Ambient 27 27 27 27
Primary AH Outlet 301 287 268 258
Second .AH Outlet 304 289 269 259
Gas
SH Platen inlet 1133 1087 1040 1022
RH Front inlet 983 932 876 851
RH Rear inlet 833 784 730 705
Final SH inlet 733 691 646 625
LTSH inlet 626 592 557 541
Economiser inlet 466 443 418 407
Air heater inlet 327 308 287 276
Air heater outlet (Corr) 125 119 121 120
III. PRESSURES (steam & water)
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Pressure
Super Heater outlet 147.5 120.0 92.8 80.9
LTSH Outlet 154.4 125.0 96.9 84.9
Drum 158.3 127.8 99.2 87.2
Economiser inlet 163.1 131.6 102.3 90.1
Reheater inlet 37.20 29.80 22.50 19.40
Reheater outlet 35.60 28.50 21.50 18.50
Pressure Drop
Super heater system 10.8 7.8 6.4 6.3
Reheater system 1.6 1.3 1.0 0.9
Economiser (Friction only) 2.7 1.7 1.0 0.8
I. FLOW
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Steam
Super heater outlet 626.5 500.4 377.7 324.6
Reheater outlet 562 452.1 344.1 297.4
Water
Feed water 626.5 500.4 377.7 324.6
SH spray 11.8 23.9 27.5 28.2
RH spray - - -
Air
Primary AH Outlet 260 245 182 172
Tempering air 31 29 24 25
Secondary AH outlet 409 282 207 152
Total combustion Air 785 641 498 434
Flue gas
RAPH inlet 872 712 553 482
RAPH outlet 957 793 630 558
Fuel
Coal
161.0 131.5 101.7 89.1
(HHV= 3000 kcal/kg)
II. TEMPERATURE
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Steam
Sat. temp. in Drum 345 327 307 297
LTSH inlet 350 339 326 320
LTSH outlet 406 409 411 412
Platen SH inlet 397 382 361 348
Platen SH outlet 508 510 515 516
Final SH inlet 508 510 515 516
Final SH outlet 540 540 540 540
RH inlet 348 351 354 355
RH outlet 540 540 540 540
Water
Economiser inlet 245 235 222 216
Economiser outlet 293 284 273 269
Air
Ambient 27 27 27 27
Primary AH Outlet 301 287 268 259
Second .AH Outlet 304 289 269 260
Gas
SH Platen inlet 1131 1083 1039 1019
RH Front inlet 982 930 875 849
RH Rear inlet 833 783 730 705
Final SH inlet 733 691 646 625
LTSH inlet 626 593 557 541
Economiser inlet 466 443 418 407
Air heater inlet 327 308 287 277
Air heater outlet (Corr) 126 122 122 123
III. PRESSURES (steam & water)
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Pressure
Super Heater outlet 147.5 120.0 92.8 80.9
LTSH Outlet 154.4 125.0 96.9 84.9
Drum 158.3 127.8 99.2 87.2
Economiser inlet 163.1 131.6 102.3 90.1
Reheater inlet 37.20 29.80 22.50 19.40
Reheater outlet 35.60 28.50 21.50 18.50
Pressure Drop
Super heater system 10.8 7.8 6.4 6.3
Reheater system 1.6 1.3 1.0 0.9
Economiser (Friction only) 2.7 1.7 1.0 0.8
I. FLOW
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Steam
Super heater outlet 626.5 500.4 377.7 324.6
Reheater outlet 562 452.1 344.1 297.4
Water
Feed water 626.5 500.4 377.7 324.6
SH spray 13 24.9 28.6 29.4
RH spray - - -
Air
Primary AH Outlet 182 153 140 113
Tempering air 66 38 40 16
Secondary AH outlet 439 352 222 210
Total combustion Air 772 628 487 424
Flue gas
RAPH inlet 845 687 553 464
RAPH outlet 927 765 608 539
Fuel
Coal
118.8 96.6 74.9 65.0
(HHV= 3000 kcal/kg)
II. TEMPERATURE
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Steam
Sat. temp. in Drum 345 327 307 297
LTSH inlet 351 339 326 321
LTSH outlet 404 408 409 410
Platen SH inlet 395 379 358 344
Platen SH outlet 508 511 515 516
Final SH inlet 508 511 515 516
Final SH outlet 540 540 540 540
RH inlet 348 351 354 355
RH outlet 540 540 540 540
Water
Economiser inlet 245 235 222 216
Economiser outlet 292 282 272 267
Air
Ambient 27 27 27 27
Primary AH Outlet 302 285 267 256
Second .AH Outlet 306 287 267 257
Gas
SH Platen inlet 1153 1106 1060 1043
RH Front inlet 997 944 888 862
RH Rear inlet 842 791 737 711
Final SH inlet 739 695 650 628
LTSH inlet 628 594 558 541
Economiser inlet 466 442 417 406
Air heater inlet 325 306 285 274
Air heater outlet (Corr) 131 124 125 117
III. PRESSURES (steam & water)
HP Heaters in service
Description
100% TMCR 80% TMCR 60% TMCR 50% TMCR
Pressure
Super Heater outlet 147.5 120.0 92.8 80.9
LTSH Outlet 154.4 125.0 96.9 84.9
Drum 158.3 127.8 99.2 87.2
Economiser inlet 163.1 131.6 102.3 90.1
Reheater inlet 37.20 29.80 22.50 19.40
Reheater outlet 35.60 28.50 21.50 18.50
Pressure Drop
Super heater system 10.8 7.8 6.4 6.3
Reheater system 1.6 1.3 1.0 0.9
Economiser (Friction only) 2.7 1.7 1.0 0.8
AXIAL SEALS:
BY PASS SEALS
4.6 FD FAN
SL No. DESCRIPTION
1 PROJECT NTPC-UNCHAHAR-5
2 APPLICATION Forced Draft Fan
3 FAN TYPE AP1-18/11
4 NO.OFF/BOILER TWO
FAN DESIGN RATING
5 CAPACITY (m /s) 99
6 Total head developed(mmwc) 487
7 Temp. of medium(deg.C) 50
8 Density (kg/m) 1.051
9 Speed (rpm) 1480
FAN RESERVE
10 Flow (%) 67.8
11 Pressure(%) 81.0
FAN DRIVE COUPLING
12 Type Spacer Type
DRIVE MOTOR
13 Rating(kW) 625
14 Speed (rpm) 1480
15 Volts(volts) 6600
LUBRICATION EQUIPMENT:
16 Fan 80 LPM FOLS(ISO VG 68)
17 Motor Grease Lubricated(Servogem3)
18 TYPE OF FAN REGULATION Blade Pitch Control
BEARINGS
19 Fixed bearing 7230BUA & NU230 C3
20 Free bearing NU 230 C3
21 Power absorbed at the motor coupling at rated oput(p 549 KW
max)
22 Recommended motor rating 625 KW
23 Fan speed 1480 RPM
24 Motor speed 1480 RPM
25 Torque at ‘p’ max.referred to the motor speed 362 KGM
26 Density of the medium handled 1.05 Kg/cubic meter
27 Gd2 referred to fan shaft 492 Kg sq meter.
4.9 PA FAN
SL No. DESCRIPTION
1. CUSTOMER NUMBER 0362
2. PROJECT NTPC-UNCHAHAR-5
3. APPLICATION PRIMARY AIR FAN
4. FAN TYPE AP 2-17/12
5. NO.OFF/BOILER TWO
6. MEDIUM Atmospheric air
7. LOCATION OUTDOOR
8. FAN DESIGN RATING
CAPACITY (m /s) 90.9
Total head developed(mmwc) 1350
Temp. of medium(deg.C) 50
Density (kg/m) 1.050
Speed (rpm) 1480
9. FAN RESERVE
Flow (%) 95.5
Pressure(%) 51.5
10. FAN DRIVE COUPLING
Type Spacer Type(Regiflex)
11. DRIVE MOTOR (VFD)
Rating(kW) 1625
Speed (rpm) 1480
Volts(volts) 6600
12. LUBRICATION EQUIPMENT
Fan 60 LPM FLOS(OIL-ISO VG68)
13. TYPE OF FAN REGULATION Blade pitch control
14. BEARINGS
Drive End Bearing NU 236 C3 + 70 40 BUA
Non Drive End Bearing NU 236 C3
15. Power absorbed at the motor coupling at rated 1443 kw
output(p max)
16. Recommended motor Rating 1600 KW
17. Fan speed 1480 RPM
18. Motor speed 1480 RPM
19. Torque at ‘p’ max. Referred to the motor speed 950 Kgm
20. Density of the medium handled 1.05 Kg/cubic meter
21. Gd2 referred to fam shaft 1640 Kg sq meter
COAL FIRING
5.1 MILL
SL No. DESCRIPTION
1 Type of mill Bowl Mill
2 Size of mill XRP 883
3 No of mills provided per boiler 6
4 Mill speed 600 RPM
5 Rated PF fineness 70 % through 200 mesh
99% through 50 mesh
5.5 DENSEVEYOR
(Model 6/8/5)
SL
DESCRIPTION Data / Particulars
No.
1. Quantity Reqd. 1 No. per Mill
2. Location Total : 6 Nos
3. Denseveyor Model Below Pyrite Hopper 6/8/5
4. Total Cycle Capacity (V) in Ft3 /M3 6 CFT (0.17 M3) Effective / 7 CFT (0.198 M3) Gross
5. Pressure Rating 4.5 kg/cm2 (g)
6. Design Pressure 5.0 kg/cm2 (g)
7. Material Temperature 200 Deg.C
8. Outlet Pipe Size(inches) 5 inches (125 NB)
9. Material inlet size 200NB
10. Air Inlet Size (NB) 80 NB
11. Material of construction Denseveyor Body IS2062 – Gr, A Outlet Bend ACI
12. Hydro Test Pressure 10 kg/cm2 (g) duration 30 minutes
13. Design Code IS 2825 Class-3
14. Design Temp. Weld joint efficiency 0.6 200 deg. C
15. Drawing No. MB/C-499/34705D.
16. Painting As per approved painting schedule
SL
Description Values
No.
A. PERFORMANCE DATA
1. OIL GRADE LFO/LSHS/HFO/HPS-OIL
2. OIL POUR POINT 72 C
3. SP.GRAVITY AT 50 0.83/0925/0.855
4. PUMPING TEMP. 33 TO 130 C
5. OIL VISCOSITY min/max 180/500
6. CAPACITY AT min CST 66.7 LPM@180cst
7. CAPACITY AT max.CST 71LPM @50 cst
8. SUCTION PRESSURE -0.5 KG/cm (g)
9. DELIVERY PRESSURE +10 Kg/cm (g)
10. NPSH REQUIRED 5 METERS WC At max. cst
11. NPSH AVAILABLE FLOODED
12. RPM 1445
13. SENSE OF ROTATION CW as seen from motor end
14. BHP at min CST 2.6 KW
15. BHP AT max CST 4.0 KW
16. PUMP EFFICIENCY 40% @ MIN CST
B PERFORMANCE GRAPH
1. PRESS VS FLOW & BHP ENCLOSED
2. CST VS NPSH REQD. N.A.
3. SPEED VS TORQUE ENCLOSED
C. PUMP CONSATRUCTION DETAILS
1. MOUNTING Horizontal Foot
2. PITCH & ROTOR DIA N.A.
3. PUMP GD 2 0.0011 Kg-m2
4. NOZZLES IN 1.5 INCH 150 LBS FANGED
5. NOZZLES OUT 1.5 INCH 300 LBS FLANGED
6. INLET NOZZLE POSITION Horizontal-side
7. OUTLET NOZZLE POSIT. SIDE
8. BODY & COVER MATL. A-216 Gr.WCB
9. INSERT MATL N.A
10. ROTOR/SHAFT MATL SS 316(CF8M)/EN8
11. IDLERS MATL. IS 210 GR.FG260
12. BEARING BUSH MAT. SINTERED BRONZE
13. BASE FRAME MATL. M.S.
14. BODYDESIGN/TEST PR 20/25 Kg/Cm(g)
D. BEARINGS
1. TYPE & NUMBER OFF BALL BEARINGl
2. POSITION EXTERNAL
3. ISO NO.& CLEARANCE C3
4. LUBRICANT GRADE GREASE
5. QTY. & FILLING FREQ.
E. COUPLING (3 PIECE,PIN-PUSH)
1. MAKE LOVEJOY
2. MODEL NO. & SIZE RC-042
3. GD2 0.013KG/M
4. DOUBLE PIECE SIE Fitted onto pump shaft in flush
5. SINGLE PIECE To fit motor shaft in rough bore con
F. MECHANICAL SEAL
1. ACTION SINGLE
2. MAKE JOHN CRANE
3. MODEL NO./SIZE 2100/20
4. 0 RING/SPRING MATL. VITON
5. ROTARY RING MATL. CARBON
6. STATIONARY RING MATL SS
7. SUCTION PRESS MAX. 7 kg cm (g)
D. BEARINGS
1. TYPE & NUMBER OFF BALL/l NO
2. POSITION EXTERNAL
3. ISO NO.& CLEARANCE JC3 (Z2)
4. LUBRICANT GRADE GREASE
5. QTY. & FILLING FREQ. 22gms after very 6000 hrs running
E. COUPLING (3 PIECE,PIN-BUSH)
1. MAKE LOVEJOY
2. MODEL NO. & SIZE RC-070
3. OD 0.0926KG/M
4. DOUBLE PIECE SIDE Fitted onto pump shaft in flush
5. SINGLE PIECE To fit motor shaft in rough bore con
E. MECHANICAL SEAL
1. ACTION SINGLE
2. MAKE BURGMANN
3. MODEL NO./SIZE M3/45
4. 0 RING/SPRING MATL. VITON
5. ROTARY CARBON
6. STATIONARY RING MATL SS
7. SUCTION PRESS MAX. 4 kg /cm2 (g)
C. BEARINGS
1. TYPE & NUMBER OFF BALL/l NO
2. POSITION EXTERNAL
3. ISO NO.& CLEARANCE JC3 (Z2)
4. LUBRICANT GRADE GREASE
5. QTY. & FILLING FREQ. 08gms after very 4000 hrs running
D. COUPLING (3 PIECE,PIN-BUSH)
1. MAKE LOVEJOY
2. MODEL NO. & SIZE RC-38
3. OD 0.009KG/M2
4. DOUBLE PIECE SIDE Fitted onto pump shaft in flush
5. SINGLE PIECE To fit motor shaft in rough bore con
E. MECHANICAL SEAL
1. ACTION SINGLE
2. MAKE BURGMANN
3. MODEL NO./SIZE M3/ 25
4. 0 RING/SPRING MATL. VITON /SS
5. ROTARY CARBON
6. STATIONARY RING MATL SS
7. SUCTION PRESS MAX. 4 kg /cm2 (g)
G PERFORMANCE GUARANTEE
1. 1.AS PER VDMA 24284-GROUP –II CLASS-II YES
6.0 ESP
Sl DESCRIPTION
evaporation
evaporation
correction
Bowdown
tag safety pressure Relieving Total Yes/No
Locantio
Capacity
factor
Total
no. valve Kg/sq cm(g) capacity relieving
% of
% of
% of
per valve capacity
Open Closed (kg/h) (kg/h) Tag no.
1750wb SL1
SV2 Consol 182.6 173.5 5.0 186052 81.80 __ NO
1750wb 556333
SV3 Consol 184.4 175.2 5.0 187876 105.81 __ NO
1750wb
SV4 Consol 165.5 158.9 4.0 163287 163287 24.01 0.812 YES
SH
1750wd SL5
SV5 Consol 163.8 158.6 3.2 102000 20400 30.00 30.0 0.745 YES
ERV
SH
1786wb
1786wd 427560
SV10 Consol 44.3 42.1 5.0 146937 0.753 NO
1786wd
SV11 Consol 41.1 39.7 3.5 103699 207398 35.24 35.24 0.753 YES
HRH
ERV
& 1525vx
SV12 SL7 & 8
SV13 Consol 40.0 38.0 4.0 14591 14591 0.909 YES
SB
1811jb- SL11
6x-20 ---- -----
.
SECTION - II
TURBINE
&
AUXILIARIES
10.1 SPECIFICATION OF TURBINE
LOAD
Rated Load 210 MW
Maximum Load under valve wide open(VWO) condition 220.6 MW
CONSTRUCTION
Three cylinder reheat condensing turbine
Single flow HP Turbine with 19 reaction stages Type: H 30-25
Double flow IP Turbine with 19 reaction stages per flow Type: M 30-20
Double flow LP Turbine with 8 reaction stages per flow Type; N 30-2x5
Main Stop and Control valves Type: EV 200
Reheat Stop & Control Valves Type: IV 320
Swing Check Valve in cold reheat line DN-450 Make : BHEL,Trichy
Bypass Stop & Control Valves DN-200
Extraction Swing Check valves
Extraction 1: No valve
Extraction 2:1 Swing check valve with actuator and DN 500 MAKE: BHEL,Trichy
1 Swing check valve without Actuator
Extraction 3: 1 Swing check valve with Actuator and DN 400 MAKE: BHEL,TRICHY
1 swing Check valve without Actuator
Extraction 4: 1 Swing check Valve with Actuator and DN 300 MAKE: BHEL,Trichy
1 Swing check valve without Actuator
Extraction 5: 1 Swing check valve with Actuator and DN 200 MAKE: BHEL Trichy
1 swing check valve without Actuator
Extraction 6: No valve
SPEED
Rated speed 50.0 c/s
Speed limitation in load & station operation
Max.speed, no time limitation 51.5 c/s
Min.speed no time limitation 47.5 c/s
Permissible for maximum 2 hours during the Life of
LP blading
Speed below 47 .5 c/s
Speed above 51.5 to 60 c/s
Speed exclusion range at operation without load* 11.7 to 47.5 c/s
Standard over speed trip setting Max.55.5 c/s
This speed range should be passed through in one smooth operation to avoid endangering the blades due to
resonance.
STEAM PRESSURE
Rated Long time opn. Short time opn. Unit
Initial Steam 147.10 154.45 176.50 Bar
st
Before 1 HP drum stage 135.7 142.48 149.27 Bar
HP cylinder exhaust 38.67 44.48 46.41 Bar
IP cylinder stop valve inlet 34.81 40.38 41.77 Bar
Extracation 6 38.67 44.48 46.41 Bar
Extraction 5 16.06 18.05 18.95 Bar
Extraction 4 6.90 8.28 8.28 Bar
Extraction 3 2.30 2.80 2.80 Bar
Extraction 2 0.876 1.078 1.078 Bar
Extraction 1 0.416 0.516 0.516 Bar
LP cylinder exhaust 0.1187 0.30 0.30 Bar
Rated parameters are at 210 MW with 3 % make up and 0.1187 bar back pressurewith all heaters in service
and rated steam condition
Long term operation : Upper Limit value ,permissible without time limit
All pressures are in absolute pressures
LOW VACUUM TRIP,STANDARD SETTING
Hydraulic low vacuum trip 0.3 bar
Electrical low vacuum trip 0.3 bar
Hydraulic low vacuum trip bypass operation 0.6 bar
AXIAL SHIFT
Alarm Plus / Minus 0.5 mm
Trip Plus / Minus 1.0 mm
DIRECTION OF ROTATION
Anti clock wise when viewed from Front Pedestal towards the Generator
Steam Temperature
Rated value Long-term value, 400 hrs. 80 hrs. per year Unit
Annual subject to annual per year Max.15 min in
average average individual case
Main steam at 537 545 551 565 C
HP stop valve
inlet
HRH steam at 537 545 551 565 C
IP stop valve
inlet
STEAM TEMPERATURE
Rated Long term 80 hrs.per In special Unit
value operation year,Max.15 min.in cases at no
individual case load
HP Turbine exhaust 346 348 428 500.0 C
Extraction 6 346 348 428 500.0 C
Extraction 5 427 432 467 C
Extraction 4 314 324 364 C
Extraction 3 197 208 252 C
Extraction 2 108 128 168 C
Extraction 1 77 97 142 C
LP turbine exhaust 49 70 70 100 C
Rated parameters are at 210 MW with 3 % make up and 0.1187 bar back pressurewith all heaters in service
and rated steam condition
Long term operation : Upper Limit value ,permissible without time limit
All pressures are in absolute pressures
VIBRATION
Absolute Bearing housing Absolute Shaft vibration
vibration
Standard alarm setting 84 µm 200 µm
Maximum alarm setting 106 µm 320 µm
Limit value for tripping 106 µm 320 µm
WEIGHTS
HP turbine,completely assembled 48.5 T
IP turbine,top half outer casing 13.2T
IP turbine,top half inner casing, complete with blading 8.0 T
LP turbine,top half outer casing complete 17.7 T
LP turbine,top half inner outer casing, complete with blading, guide blade carriers and diffusers 15.5 T
HP turbine rotor, complete with blading 7.5 T
IP turbine rotor, complete with blading 15.8 T
LP turbine rotor, complete with blading 48.0 T
Main stop & control valve, complete with servo motors, without bend & pipe section 10.0 T
Reheat stop and Control valve, complete with servo motors, without bend & pipe section 12.0 T
11.0 TURBINE OIL SYSTEM
12.0 DEARATOR
Sr. No. Description
1 Design pressere 7.4 ata
2 Hydro test pressure 9.62 ata
3 Storage tank design temperature ( Max / Min ) 250 / 0 C
4 Heater design Temp ( Max / Min ) 369 / 0 C
5 Hydrostatic temp ( Max / Min ) Ambient / 17
6 Radiography Full
7 Corrosion allowance
- shell / head 3.2 mm
- RF pads / nozzles / flange 1.6 mm
8 Oxygen content at outlet 0.005 ( cc / lit )
9 Storage tank capacity( between NL & LLL for 10 minutes capacity ) 130 cub m
10 Operating pressure 6.303 ata
11 Operating temp 160 C
12 No. Of trays 240
13 No. Of spray nozzles 48
14 Weight ( kgs)
- Dry 69232
- operating 229600
- flooded 365430
14.1 HPH-5
Sl no. DESCRIPTION
1 Size 1300 X 7367
2 Type U bend tube
3 Position Horizantal
4 Surface per unit 708.1 M2 ( EFF )
744.1 M2 ( TOTAL)
SHELL SIDE TUBE SIDE
UNIT STEAM DRAINS FEED WATER
5 Total fluid entering Kg/hr 33494 58775 627692
6 Inlet enthalpy Kcal /kg 791.4 208 167.7
7 Outlet enthalpy Kcal /kg - 170.3 204.4
8 Inlet temp C 426.5 203.0 163.5
9 Outlet temp C 168.5 198.9
10 Operating Pressure Kg/cm2 15.497 - 205
11 Velocity m/sec 1.85
12 TTD C 0 - -
13 DCA C - 5 -
14 Pressure drop Kg /cm2 0.2 0.18 0.66
15 Steam Sat temp C 198.9
Heat exchanged Surface LMTD Heat transfer rate
( MKcal/ Hr ) (M2) ( C) ( Kcal/hr/m2/C)
16 Desuperheating section 3.57 79.1 101.3 446
17 Condensing section 16.54 491.3 13.8 2446
18 Drain cooling section 2.9 137.8 14 1508
SHELL SIDE TUBE SIDE
19 Design pressure 19.0 kg /cm2 & full 288 kg /cm2
vacuum
20 Test pressure 24.7 Kg / cm2 375 Kg /cm2
21 Design temp Inner shell-445 C Straight tube- 235 C
Main shell-215 C Bend Portion- 215 C
TUBE
21 Material SA 688 TP 304
22 No 933
(Effective No of tubes-930)
23 OD 15.875
24 Thickness 13 /14 BWG
R1-R5 13 BWG ( Min)
R6-R25 14 BWG ( MIN)
SHELL
25 Material SA 516 Gr 70
26 Length 6775 mm
27 ID 1300
28 Thickness 16
14.2 HPH-6
Sl no. DESCRIPTION
1 Size 1300 X 8557
2 Type U bend tube
3 Position Horizantal
4 Surface per unit 820.6 M2 ( EFF )
854.8 M2 ( TOTAL)
SHELL SIDE TUBE SIDE
UNIT STEAM DRAINS FEED WATER
5 Total fluid entering Kg/hr 358775 627692
6 Inlet enthalpy Kcal /kg 737.9 204.4
7 Outlet enthalpy Kcal /kg - 208 254
8 Inlet temp C 344 198.9
9 Outlet temp C 203.9 245
10 Operating Pressure Kg/cm2 37.243 - 204
11 Velocity m/sec 1.85
12 TTD C 0 - -
13 DCA C - 5 -
14 Pressure drop Kg /cm2 0.25 0.06 0.77
15 Steam Sat temp C 245
Heat exchanged Surface LMTD Heat transfer rate
( MKcal/ Hr ) (M2) ( C) ( Kcal/hr/m2/C)
16 Desuperheating section 3.19 97.7 51.2 639
17 Condensing section 25.3 611.6 16.5 2510
18 Drain cooling section 2.65 110.4 17.3 1396
SHELL SIDE TUBE SIDE
19 Design pressure 49.0 kg /cm2 & full 288 kg /cm2
vacuum
20 Test pressure 63.7 Kg / cm2 375 Kg /cm2
21 Design temp Inner shell-350 C Straight tube- 285 C
Main shell-265 C Bend Portion- 265 C
TUBE
21 Material SA 688 TP 304
22 No 933
(Effective No of tubes-930)
23 OD 15.875
24 Thickness 13 /14 BWG
R1-R5 13 BWG ( Min)
R6-R25 14 BWG ( MIN)
SHELL
25 Material SA 516 Gr 70
26 Length 7850 mm
27 ID 1300
28 Thickness 32
15.0 CONDENSER:
17.1 CEP
Sl.No. Description
rd
Type EN6J40(3 stage dummy)
Direction of rotation, viewed from motor end Clockwise
Rated output, cum/hr 660
Differential head,(m) 210
Liquid pumped Condensate
Liquid temperature,(deg.C) 49.2
Specific weight, (kg/cum) 988.4
Discharge bore diameter, (mm) 495
Discharge bore diameter,(mm) 300
Speed, (rpm) 1486
Power absorbed, (kw) 466
Efficiency (%) 80
NPSH required,(m) 2.75
Thrust bearing
Make M/s.Michell Bearings India
Type 7-SNT, vertical thrust & guide brg.
Flexible coupling
Make M/s.Bibby Transmissions,UK
Type Flexible membrane
Model No. TF 1250
Drive motor
Manufacturer M/s BHEL,Hardwar
Type SCIM
Rating,(KW) 550
Speed, (rpm) 1486
Electrical supply 6.6 KV,3-PH,50 Hz
1.01.00 Design flow rate(T/Hr) 652.344
st
1.02.03 NPSH required at 1 stage impeller for
(a) 3% head breakdown (m) 2.75
(b) 1% head breakdown(m) 3.05
(c) 0% head breakdown(m) 3.35
(d) 40,000 hrs erosion life of first stage 3.35
impeller(m)
1.03.00 Design discharge conditions
1.03.01 Discharge pressure(ata) 21
1.03.02 TDH (m) 210
1.03.03 Shut off head(m) 250
1.04.00 Pump speed(rpm) 1486
1.05.00 Power consumption:
1.05.01 Power input to motor at 50 Hz/47.5 Hz(kW) 491/421
1.05.02 Loss in motor at 50 Hz/47.5 Hz(kW) 25/21
1.05.03 Power input to pump at 50 Hz/47.5 Hz(kw) 466/400
1.05.04 Efficiency of pump alone(%) 80
1.05.05 Overall efficiency of pumpset(%) 76
1.06.00 Suction Specific speed for first stage indicating 10902
the flow at which the same is considered(US
Units)
1.07.00 Canister losses(mwc) 0.3
1.08.00 Seal water requirement (flow/pressure/temp.)
1.08.01 Flow m/hr(max.) 1.2
1.08.02 Pressure(ata/range) 3-6
1.08.03 Temp.(C/range) 40-50
1.09.00 Minimum flow continuous stable operatin(m3/hr) 210
1.10.00 On set recirculation flow(m/hr) -
1.11.00 Peripheral speed at the eye of first stage 17.7
impeller (m/sec.)
1.12.00 Maximum thrust down at 50 Hz(kgs) 3380(with closed valve & worn clearance)
Maximum thrust down at 51.5 Hz(kgs) 3586(with closed valve & worn clearance)
1.13.00 Manufacturer BHEL/HYD.
1.14.00 Model Number and No. of pumps EN5J40,2 NOS.
1.15.00 Number of stages 5
1.16.00 Type first stage impeller Double suction radial flow
1.17.00 Impeller outer diameter(mm) 360-Ist stage,395-inter stage
1.18.00 Suction specific speed for inter stage(US units) 5988
1.19.00 Design pressure of bowl and discharge 40
components(ata)
1.20.00 Outer casing(can)
1.20.01 Minimum wall thickness(mm) 10
1.20.02 Design pressure(ata) 8
1.20.3 Depth below pump mounting flange(mm) 4833
1.21.00 Suction connection
1.21.01 Size/schedule NB 500
1.21.02 Type of connection with piping Flanged
1.21.03 Depth of centerline below pump mounting 525
fange(mm)
1.22.00 Discharge connection:
1.22.01 Size/schedule NB 300
1.22.02 Type of connection with piping Flanged
1.22.03 Height of centerline above pump mounting 300
flange(mm)
1.23.00 Critical speeds:(with worn clearances)
1.23.01 First critical speed in water(rpm) 5555
1.23.02 Second critical speed in water(rpm) 5923
1.24.00 GD2 of rotor including coupling(kg/m) 20
1.25.00 Impeller shaft(Bottom shaft)
1.25.01 Length (mm) 2790
1.25.02 Diameter (mm) 66
1.25.03 Span between bearings(mm) 750
1.26.00 Intermediate shafts(Top shaft)
1.26.01 Length (mm) 3551
1.26.02 Diameter(mm) 80
1.26.03 Span between bearings (max.)(mm) 450
1.26.04 Method of coupling with adjacent shafting Muff coupling
1.27.00 Radial bearings:
1.27.01 Type & number Cutless rubber & 7 nos.
1.27.02 Size(mm) 85/4- 5 mps/ 70.4-2 Nos.
1.28.00 Thurst bearing
1.28.01 Located in pump/motor Pump
1.28.02 Type & number Tilting pad 7SNT & 1 No.
1.28.03 Design load(kg) 4471
1.28.04 Max load(kg) -
1.29.00 Bearing lubrication type:
1.29.01 Radial bearing Medium(condensate)
1.29.02 Thrust bearing Oil sump
1.29.03 Recommended hole size of suction strainer 350 microns
MAKE BONFIGLIOLI,ITALY
TYPE VF 49 F1 7 P71 B14 B6 + BN71 B4 B14
TYPE OF BEARINGS WORM – TAPER ROLLER BEARING
WORM WHEEL – BALL BEARNG
TYPE OF LUBRICATION SYNTHETIC OIL
LUBRICATION MAKE MOBIL/CALTEX
GRADE MOBIL GLYGOIL/CALTEX FOR EQUIVALENT
TEMPERATURE - 30 C TO + 90C
METHOD OF LUBRICATION SUPPLY OIL CAN
REQUIRED TO BE LUBRICATED BEARINGS & GEARS
INITIAL CHARGE QUANTITY 0.5 LITERS
REFILLING PERIOD
MAIN GEAR CASE AFTER 18 MONTHS
BEARINGS AFTER 10,000 OPERATING HRS(or)
AFTER 36 MONTHS
GEARED LIMIT SWITCH AFTER 36 MONTHS
REFILLING QUANTITY 0.5 LITERS
LUBRICATION OF FLUSHING PUMP
MAKE MICROFINISH PUMPS PVT.LTD.
TYPE HORIZONTAL CENTRIFUGAL BACK PULLOUT
TYPE OF BEARINGS DEEP GROOVE BALL BEARINGS
TYPE OF LUBRICATION OIL
LUBRICATION MAKE MOBI/CALTEX
GRADE MOBIL GLYGOIL/CALTEX FOR EQUIVALENT
TEMPERATURE -90C TO +150C
METHOD OF LUBRICATION SUPPLY OIL CAN
REQUIRED TO BE LUBRICATED BEARINGS
INITIAL CHARGE QUANTITY 950 ML
REFILLING PERIOD AFTER 30,000 OPERATING HOURS
REFILLING QUANTITY 950 ML
LUBRICATION OF MOTOR FOR FLUSHING PUMP
MAKE KIRLOSKAR ELECTRIC (INDIA)
TYPE SQUIRREL CAGE INDUCTION MOTOR
TYPE OF BEARINGS DEEP GROOVE BALL BEARINGS
TYPE OF LUBRICATION GREASE
LUBRICATION MAKE MOBI/CALTEX
GRADE MOBIL GLYGOIL/CALTEX OR EQUIVALENT
TEMPERATURE -90C TO +150C
METHOD OF LUBRICATION SUPPLY GREASE GUN
REQUIRED TO BE LUBRICATED BEARINGS
INITIAL CHARGE QUANTITY DE 19 Cu,Cm,NDE 19 CU.Cm
REFILLING PERIOD AFTER 3500 OPERATING HOURS
REFILLING QUANTITY DE 19 Cu,Cm,NDE 19 CU.Cm
Type RB(Medium)
Model 26RB 20 M 0
Diameter 26 mm
Quantity / Charge / system 460mm
No.of charges/system for commissioning 4 Nos.
Quantity required to be supplied/system 1840 nos.
Quantity required to be supplied for 2 systems 3680 nos.
7.3 Abrasive Balls
Type RG(Medium)
Model 25RG 20 M 0
Diameter 25 mm
Quantity/charge/system 460 nos.
No. of charges/system for commissioning 1 NO.
Quantity required to be supplied /system 460 nos.
Quantity required to be supplied for 2 systems 920 nos.
a Number/Agitator One(1)
b Make Bharat Bijlee
c KW rating 0.75
d Speed 1500 RPM
e Frame Size ----80-----
f Voltage/phase/frequency --415/3/50 cycles--
2.3.2 LEVEL GAUGE
i) Number/tank one(1)
ii) Manufacturer Sigma Instrument Co.
iii) Type Reflux type
iv) Material(Wetted Parts) S.S. 304
v) End connection 25 MM NB Flanged as
per ASA 150 #
vi Vent & drain cock ½” NPT with valves of
.S. 304
2.3.3 Level Switch HYDAZINE AMMONIA
i) Quantity Two(2) Two(2)
ii) Se rvice For low level and Low- Low,Low-Low & High
Low level in level in Measuring Tank
Storage/Mixing Tank & Low Level & Low-Low
level in Storage/Mixing
tank
iii) Make Levcon
iv) Type Capacitance Type
v) Probe type rigid
vi) Process connection 1” NB NPT(M)---------
vii) Probe Material S.S. 316
2.3.4 Breather Tank
EQUIPMENT DETAILS
1 TANK MIXING CUM STORAGE
1.2 Number one(01) Skid
1.3 Capacity, Litres 1000
1.4 Diameter & St.Height,mm 1100 1250
1.5 Thickness of shell & dish,mm 3.0
1.6 Material S.S. 304
2.0 Accessories:
i) Motorised agitator Provided
ii) Level indicator provided
iii) low level switch Provided
iv) Dissolving basket Provided
2.1 Accessories details
2.1 Motorised agitator
i) Number/Tank One(01)
ii) Type Geared Motor Driven
iii) Manufacturer Remi
iv) Material of shaft & impeller S.S. 304
6.2.1 Motor details
i) Number/Agitator one(01)
ii) Make Remi
iii) KW rating 0.75
iv) speed 180/200 RPM
v) Voltage/phase/frequency 415/3/50 cycles
2.2 Level Gauge
i) Number/Tank One(01)
ii) Manufacturer Sigma Instrument Co.
iii) Type Reflux Type
iv) Material of wetted parts S.S. 304
v) End connection 25 MM NB Flanaged
vi) Vent & drain cock ½” S.S. 304
2.3 Level Switch(Low)
i) Number/Tank One(01) each for low level
ii) Make Levcon Insrtruments
iii) Type Capacitance
iv) P robe marterial S.S. 316
2.4 Dissolving Basket
i) Number/tank One(01)
ii) Material of const. S.S. 304
iii) Type Removable
iv) Screen Size 3 mm dia opening
2.5 Dissolving Basket
i) Number/Tank One(01)
ii) Marterial of const. S.S.304
iii) Type Removable
iv) Screen size 3 mm dia opening
2.6 Piping, valves,flanges
2.7 Piping:
i) Size(mm) 15/25/40
ii) Material S.S. 304L
iii) Schedule 40
2.8 VALVES
i) Size ,NB 25/40
ii) Type OS & Y Type(Gate,Globe Valves)
iii) Material S.S. 316
iv) End connection Socket welded/flanged
v) Pressure Rating 800 #
2.9 FLANGES
i) Material S.S. 304 L
ii) Class ASA 150 #
28.1 GENERAL
General
Job Name UNCHAHAR-5
Generator type THRI 108/44
Main Exciter type BE 70/62-30/6-10
Pilot exciter type PMG 50/29-30/16
Year of manufacture
Stator serial No.
Rotor Serial No./Rotor identification No.
Main exciter stator serial No.
Pilot exciter stator serial No.
Exciter rotor serial no./Exciter rotor identification No.
Rated Data & outputs Turbo generator Main Exciter Pilot Exciter
Apparent power 247 MVA - 35kva
Active Power 210 MW 1350 KW -
Current 9056kA 3200 A 105A
Voltage 15.75 KV 787.5v 420v 220V 22V
Speed 50 s 50 50
Frequency 50Hz - 400 HA
Power Factor 0.85 - -
Inner connection of stator winding YY - -
H pressure 2 Bar - -
Cont. Perm. unbalanced load 8% - -
Rated field current rated output 2080A - -
Rated field voltage 260V - -
Resistance in Ohms at 20 C Turbo generator Main Exciter Pilot Exciter
Stator Winding U-X 0.0009620 U-0 0.0043 ohms
U-X 0.0009620 F1-F2 2,3ohms V-O 0.0043 ohms
W-Z 0,0009620 W-O o.0043 ohms
Rotor Winding U-V0.00064 ohms
F1-F2 0.09421ohms U-W0.00064 ohms
V-W 0.00064 ohms
&
AUXILIARIES
29.0 TRANSFORMERS
29.1 GENERATOR TRANSFORMERS
28 Core
-Type of construction - Three limb core
2
-Net core area Cm 1728
-Core material and grade CRGO/27MOH
-Type of joints between core and yoke Mitered
-Thickness of stamping 0.27 approx
-Percentage silicon content 3 to 5
-Approximate flux density in core at rated
frequency and at
-90% voltage 1.38
-100% voltage 1.53
-110% voltage 1.68
No load current at rated Frequency
-90% voltage Less than 1%
-100% voltage Less than 1%
110% voltage 1% approximately
29 Winding
-Type of winding
-LV - Helical
-HV - Disc
-TAP - Disc
-Block/ circle
-LV 16x38mm + 16 additional
-HV 16x38mm
TAP 24x38mm
-Current density at rated load (LV/HV/TAP) - 2.76/2.26/2.58
Weight
Core & Winding 1550 Kgs. ( Approx.)
Insulation 35 Kgs (Approx.)
Oil 590 Kgs. / 680 Ltrs. (Approx.)
Total 3440 Kgs. (Approx. )
Shipping 3370 Kgs. (Approx.)
Shipping Details
a)Weight of heaviest package KG 1450 ( Approx. )
b)Total shipping weight KG 1450 ( Approx.)
c)No. of packages One
d)Dimensions of largest package mm 1400 X 1530 X 2180 (Approx.)
e)Parts detached for transport Nil
Core
a)Form of core Circular, Core Type
b)Net core area Sq. mm. 10500 (Approx.)
c)Type of joint between core and yoke Interleaved
d)Thickness of stampings mm 0.28 (Approx.)
e)Percentage silicon content 3.15 (Approx.)
f)Maximum flux density in core at rated
Frequency and at
90 % Voltage Wb / sq. m 1.35 (Approx.)
100 % Voltage Wb / sq. m 1.50 (Approx.)
i. 110 % Voltage Wb / sq. m 1.65 (Approx.)
g)Type of core binding By Surgical Tape
Winding
a)Type of winding LV- Sprial / HV Distributed
b)Current density at rated load Run over.
i. HV Amp/sq. mm 2.14 (Approx.)
ii. LV Amp/sq. mm 2.3 (Approx.)
c)Conductor Area
i. HV Sq. mm 0.78 (Approx.)
ii. LV Sq. mm 1o3 (Approx.)
d)Maximum current density under short Circuit
i. HV Amp/ sq. mm 6.4 (Approx.)
ii. LV Amp/ sq. mm 6.9 (Approx.)
Clearances
LED’s
1 LED1-3 Charger AC ‘ON’ indicating cluster LED type lamps 230V
2 LED4,5 Float/Boost AC “ON’ indicating Cluster LED type 230V
lamps
3 LED6 Charger DC ‘ON’ indicating cluster LED type lamps 220V
4 L Cubicle fluorescent lamp with suitable fitting 210W/230V
FITLER CONDENSER
1 FC1 Filter condenser for float charger Test selected
3 SW3 Single Pole on/OFF cam type switch for contactor coll 12A
operation
4 SW4 2Pole ON/Off DC Rotary switch for DC output 300A
5. Sw5 1Poe,2 way NO Off cam type switch for selecting 16A
auto/manual mode operation of charger,(Lockable
type)/RP1134/1G
6. SW6 1Poe,2 way NO Off cam type switch for selecting 12A
Float/boost mode of operation
7 SW7 2Pole ON/OFF cam type switches for control supply 12A
8 SW8&9 1Pole ON/OFF cam type switches for the lamp & 12A
heater respectively
TRANSDUCERS
1 V-VI,V-V2 Dual output voltage transducer to charger I/P = 0-400V
output & battery for DDCMIS purpose O/P = 4-20mA
Aux.supply:220VDC
2 A-A1 Dual output current transducer for charger I/P = 0-75V
output for DDCMIS purpose O/P = 4-20mA
Aux.supply:220VDC
MISCELLANEOUS
1 H Space strip heater 100W/250V
2 TH Thermostat for the heater SA/240V
3 S 3-pin socket with switch & fuses 5A/250V AC
4 SS1-3 Metal oxide variastor type surge suppressors RDN510/20
for Transformer primary side of float cum
boost charger
5 SS4 Metal oxide variastor type surge suppressors RDN320/20
for DC output supply
6 T1 Solid state timer 5 hrs 240V AC COIL
CABLE
GLAND SIZES
SR.NO. DESCRIPTION SIZE OF THE CABLE GLAND QTY LUG SIZE QTY
OF TB (Double compression)
1 TB1 2” = 1 No. 150sq mm=03 nos.
2 TB2 2X1/4” = 04 NOS. 630sq mm= 04 nos
3 TB-3 1” = 07 NOS. 1.5 Sq mm= 28 nos.
OFFSITE
30.0 CW PUMPS
30.1 CW PUMPS
GENERAL
i)Name of manufacturer Kirloskar Brothers Ltd.
ii) Model Number BHQ 85
iii) Type Vertical, Mixed flow
iv) Country of Origin Number India
v)Number One
PUMP PERFORMANCE
i)Guaranteed design capacity cu.m/hr 12750
ii) Guaranteed Total Head at design capacity (MWC) i.e. 21.00
pressure at centerline of pump Discharge + velocity head +
static lift from Minimum water level to the centerline of
Pump’s discharge.
iii) Bowl head at guaranteed design capacity (MWC) 21.316
Total head loss from suction bell inlet to Pump discharge 0.316m
flange.(MWC) (Enclose calculations of pump internal losses)
iv) Shut off head of pump.(MWC) 39.50(Approx)
v)Rated Speed. rpm 497(Full load speed)
vi) Direction of rotation (viewed from top) Clockwise
Bowl head at rated speed and discharge.(MWC) 21.316
vii) Pump efficiency at design capacity. % 87.05
viii) Bowl efficiency at design capacity. % 89.00 Without –ve Tolerance
ix) Pump input at design capacity. kW 837.62
x)Power loss in transmission bearings. (kW)
a)Thrust (kW) 5.70 kW
b)Line bearings ( kW) 0.30
xii) Power consumption at duty point, at Motor terminals, kW 873 kW
(Guaranteed)
xiv) Maximum & Minimum capacities up to which pump can be
operated satisfactorily
Cu.M/hr Max. Min
Max. Water Level 16200 2550
Min. Water Level 16000 2550
xv) Operating range of CW pump(In terms of % of design 127 % To 20 %
(capacity)
xvi) Power input at shut of head at motor 800.84 kW (Motor Eff .95.76%)
terminals in kW
xvii) Maximum & Minimum power consumptionat motor Max. 874 Min. 720
thermals in the pump operating range in kW
xviii) Maximum shaft power required at any pump 837.62
characteristic point. (kw)
xix) Shaft power required at run out –flow (kW) 16200 X125 = 707.01 kW
(i.e. at maximum discharge), 102x0.78X3.6
CAPACITY CALCULATIONS
SITE CONDITION (DESIGN)
Site atmospheric pressure as provided in tender documents under climatological table of 107 m (Ps) = 1.001
bar(A)
Vapor pressure (Pv) at 45 deg C and 75% RH= 0.75x0.09585 bar = 0.07188 bar
NORMAL CONDITIONS
Temperature = 273 A
Relative humidity = 0%
Tn Ts
Vs = 38.1 m/Min
All performance figures are subject to tolerance as per ISO 1217 ed 1996
31.2 INSTRUMENT & PLANT AIR COMPRESSOR MOTOR
1. GENERAL
i) Manufacturer BHEL BHOPAL
ii) Equipment driven by motor COMPRESSOR
iii) Motor type SCIM
iv) Country of origin INDIA
v) Quantity 3 Nos.
2. DESIGN AND PERFORMANCE DATA
i) Frame size ILA7 560-4
ii) Type of duty CONTINUOUS
iii) Type of enclosure & method of cooling/ TETV/IC 511
Degree of Protection IP:55 AS PER CL.10 OF IEC:34-5
iv) Applicable standard to which motor IS 325
generally conforms
v) Type of mounting HORIZONTAL
vi) Direction of rotation viewed from driving end ACW
vii) Standard continuous rating at 40 deg.C 310
ambient temperature (KW)
viii) De-rated rating for specified normal condition i.e. 290
ambient temperature of 50 Deg.C (KW)
ix) Rated voltage(Volts)/Rated frequency(Hz) 6600/50
x) Permissible variation of
a) Voltage(%) +minus6.0
b) Frequency(%) +3 to – 5
c) Combined voltage and frequency 10% (abs)
xi) Minimum permissible starting voltage(%) 85
Rated speed at rated voltage and 1487
x) frequency(rpm)
xiii) At rated voltage & frequency
a) Full load current(Amp) 32
b) No load current(Amp) 11
xiv) Power Factor at
a) 100% load 0.84
b) 75% load 0.81
c) 50% load 0.73
d) No load 0.083
e) Starting 0.204
xi) Efficiency(%) at rated voltage and frequency at
a) 100% load 94.5
b) 75% load 94.0
c) 50% load 92.0
xii) Starting current(%) at
a) 100% voltage 600
b) Minimum starting voltage(85%) 460
xvii) Starting time with minimum permissible voltage
(85%)
a) Without driven equipment coupled 1.65 Secs
b) With driven equipment coupled 4.80 secs.
xviii) Safe stall time with 110% rated voltage
a) From hot condition 13.0 Secs
b) From cold condition 17.0 Secs.
xix) Torques at ( in % kg-m)
a)Starting(at minimum permissible voltage 85%) 62/118
b)Pull up at 100% voltage 80/152
c)Pull out at 100% Voltage 245/465
d)Rated load(Kgm) at 100% Voltage 190 Kg-m
e)Minimum Accelerating Torque 32/61
xx) Stator winding resistance per phase(ohms) ref. To 1.32
20deg.C
xxi) Flywheel Moment of motor (Kg-m)(GD) 56.0
xxii) No.of Permissible Starts from hot condition 2
xxiii) Locked Rotor KVA Input(Rated voltage) 2195
xxiv) Locked Rotor kVA/kW 7.57
xxv) Vibration at No load
a) Velocity(mm/s) 1.8 rms
b) Displaement(Microns) 32(p-p)
xxvi) Noise Level at No load(at 1 m) 85 dB(A)(IS:12065)
3. CONSTRUCTIONAL FEATURES
i) Stator winding Insulation
a) Class & type F/EPOXY MICA RESIN RICH
SYSTEM
b) tropacalised (Yes/No) Yes
c) Temperature rise over Cold Air Temp. of 50C© 70
d) Method of temperature measurement BY RESISTANCE
e) Stator winding connection STAR
f) Number of terminals brought out 6
ii) Type of terminal box for
a) Stator leads PHASE SEPARATED TYPE
b) Space heater CAST
c) Temperature detectors CAST
d) Instrument switches etc.
iii) For main terminal box
a) Location(from DE) LHS
b) Entry of cables BOTTOM OF TB
c) Recommended cable size ( RUNS/CORES/X- UP Tol x 3C/240 mm, AL XLPE, UN
SECTIONMM Mm/MATERIAL) AROURED.
d) Fault level(MVA) & Duration(Sec) 500 & 0.25
iv) For Bearing
a) Type a) ANTI FRICTION BALL
b) Manufacturer b) NTPC APPVD.SUPPLIER
c) Oil Quantity c) GREASE IOC SERVOGEM-3 OR
EQV.
d) Oil Quantity d) NOT APPLICABLE
a)Max.Cold Oil Temp.to Bearing NOT APPLICABLE
b)Guaranteed life in Hrs. 50000 Hrs.
c) Lubrication Type PRESSURE RELIEF
d)Whether Dial Type Thermometer Provided Yes.
e)Oil Pressure Gauge/Switch No
v) Type of cooler(CACA/CACW)/No NOT APPLICABLE
vi) Cooling water requirement for NOT APPLICABE
a) Quantity required
b) Maximum permissible inlet water temperature©
c) Pressure of water at inlet to coolers
d) Outlet temperature of water at full load (anticipated
value)
e) Cold Air temp.at outlet
vii) Weight of
a) Motor stator(kg) 2600
b) Motor rotor(kg) 650
c) Cooler(kg) –
d) Total weight (Kg) 3650
ix) Max. Permissible Temp. of Rotor© 350
x) Temp. Rise of Rotor during 1 Start 12C
xi) Temp. Rise of Rotor during 11 start 25C
xii) Surge Withstand Voltage(Stator Winding) As per IEC 34-15
a) 0.3 /3 Microsecond Surge (kVp) 20.41
b) 1.2/50 Microsecond Surge (kVp) 31.4
4.0 LIST OF ACCESSORIES
4.01 RTD s for winding Type/Nos/Leads/ Location/ PT100 SIMPLE/12/3 Between Coil
make/Res.at 0 Deg.C) Sides in slots/Reputed NTPC
Approved/100
4.02 RTDs for bearing Type/Nos/Leads/Location/ PT 100 DUPLE /2/4 in Bearing Housing
make/Res.at 0 Deg.C) Reputed NTPC approved/100
4.03.01 RTDs for HOT Air(Type/No/Leads): No.
4..03.02 RTDs for Cold Air(Type/No/Leads) No
4.04 Space Heaters yes
4.04.01 Nos. 4
4.04.02 Power (Watts) 630(Total)
4.04.03 Supply Voltage 1 PH,240 V (AC)
4.05 Sator Terminal Box
4.05.01 Type PHASE SEPARATED TYPE
4.05.02 Fault Level(MVA) 500
4.05.03 Fault level duration (secs) 0.25
4.06 Neutral TB PHASE SEPARATED TYPE
4.07 Current Transformers NOT APPLICABLE
4.07.01 Nos.
4.07.02 Ratio
4.07.03 Accuracy Class
4.07.04 Knee Point Voltage-Vk(Volts)
4.07.05 Exciting Current
4.07.06 Ma. Secondary Resistance
4.08 Dial Type Thermometer(Type make/ Mercury in Steel/NTPC
accuracy/connection Type & size approved/+minus1% Full Scale/BSP ½”
4.08.01 For Bearings(Nos.) 2
4.08.2 For Air Temp(Nos.)
a) Hot Air No
b) Cold Air No
4.08.3 Contact Rating 5A AT 240 V AC,0.5A at 220 V DC
4.08.4 Range 0-120C
4.08.5 Supply Voltage 240 V AC
4.09 Rotor Terminal Box NA
4.10 TBs for RTDs,BTDs, & space heater Yes
4.11 Sole Plate No
4.12 Foundation & Anchoring bolts Yes
4.13 Base Frame No
4.14 Speed Switch No
4.14.1 No.of contacts/Contact Rarting Set Speed Power
Supply
4.15 Insulation of Bearing no.
4.16 Forced oil lubrication NOT APPLICABLE
4.17 Oil level Indicator no
4.18 Nose Reducer No
4.19 Flow Switch for CACW Motor/Qty. No
4.19.1 No.of contact/contact Rating
4.20 Water leakage detector/quantity No
4.20.1 No.of contacts/contact rating
4.21 Techo generator NA
4.21 Grounding Pads
4.22.01 No. & Size on motor body 2 & 70X65X25 mm
4.22.02 No.of on Terminal Box 2
4.22 Vibration Pads
4.23.01 No’s & Size 60 mm Cub
4.23.02 Location On End Shield
4.24 Paint Shade RAL5012(blue)
4.25 Any other fitments
31.3 AIR DRYER
SL.NO. DATA SHEET DESCRIPTIONI
A. AIR DRYER ATLAS COPCO AIRPOWER,BELGIUM
1.MANUFACTURER MD600 W
1. MODEL NO. OIL FREESCREWCOMPRESSOR
2. TYPE OF COMPRESSOR 2 NOS.
3. TOTAL NOS OFFERED CONTINUOUS
4. TYPE OF OPERATION INDOOR
5. LO CATION BHEL/NTPC
6. QUALITY SURVEILLANCE BY AS PER APPROVED QAP
B. GUARANTEED PERFORMANCE
1. RATED FLOW 619 LPS- (38 M3/MIN)
2, DEW POINT METER AT AIR DRYER OUTLET(AT - 40 DEG.C
ATMOSPHERIC PRESSURE)
3. AIR PRESSURE DROP 0.25 BAR
4. MAX.ELECTRIC POWER INPUT 144 W
5. COOLING WATER CONSUMPTION 2.5 LPS
CORRESPONDING TO WATER TEMP.RISE OF 5
DEG C
C. MATERIAL OF CONSTRUCTION
VESSEL Cast Iron
ROTORS INORGANIC FIBRE IMPREGNATED
WITH SILICA GEL
GEAR BOX HOUSING GEARS CAST IRON CAST BRONZE
THROTTLE VALVE HOUSING SPINDLE & VALVE STAINLESS STEEL
DRAIN VALVE HOUSING FLOAT STAINLESS STEEL
EJECTOR CAST AL STAINLESS STEEL CAST AL
INLET SEALING SECTOR PIPE WITH ANODISED SURFACE
CAST AL WITH ANODISED SURFACE
D SIZE & TYPE OF CONNECTION COMPRESSED AIR
1. INLET DN 80
2. DRY AIR OUTLET DN80
3. WATER INLET & OUTLET G 1 ½”
E. NET WEIGHT 900 KG
31.4 BLOWER
MODEL GRM-125-2/2
PRESSURE 270 Mbar
DISPLACEMENT 155 M 3/HR
MOTOR H.P 2
MOTOR K.W. 1.5
MOTOR R.P.M. 3000
ELECTRIC MOTOR
MAKE CROMPTION GREAVES LTD.
TYPE Flameproof three phase fan cooled Squirrel cage induction
flanged motor
H.P. 2
K.W. 1.5
R.P.M. 2850
VOLTAGE 415+ - 10%
MAX LOAD 3.1 AMP.
FRAME DESIGNATION E90l
ENCLOSURE FLAMEPROOF
TYPE OF PROTECTION IP55
GAS GROUP IIC
TYPE OF LUBRICATION GREASED FOR LIFE
CONNECTION STAR
INSULATION CLASS F (TEMP.RISE LIMITED TO CLASS B
16. REFRIGERANT
COMPOSITION DM-PURE WATER
17 ABSORBANT
COMPOSITION LITHIUM BROMIDE(55% Concentration)
18. REFRIGERANT PUMP MODEL(1working) S410-04E-V001
MOTOR RATING(Kw) 0.4
RPM 1500
MOTOR RATED VOLTAGE(3 PHASE) 415 V
TYPE OF PUMP CANNED MOTOR
19. SOLUTION PUMP MODEL (1 Working) SS230-3 7C-V002
MOTOR RATING(Kw) 3.7
RPM 3000
MOTOR RATED VOLTAGE(3 Phase 415 V
TYPE OF PUMP CANNED MOTOR
20. VACUUM PUMP(1 NO.WORKING+1 NO.STANDBY) 7.6 M/Hr.
CAPACITY
Model VKC-8
MAKE PRECISE VACUUM SYSTEM
MOTOR RATING(Kw) 0.37
MOTOR RATED VOLTAGE(3 Phase,50Hz) 415V
21. STEAM CONTROL VALVE
TYPE PNEUMATIC
22. CONTROL PANEL
TYPE MICROPROCESSER BASED,VOLTAS
STD MAKE
23. PAINTING SPECIFICATIONS
PRIMER EPOXY BASED ZINC CHROMATE
INTERMEDIATE HIGH BUILD EPOXY REINFORCED
WITH MICACEONS IRON OXIDE
FINISH COAT POLYURETHANE BASED EPOXY
ENAMEL PAINT
24. WATER BOXES
A)PASS ARRANGEMENT
EVAPORATOR 4
ABSORBER 5
CONDENSER 1
B) FLANGE TYPE JIS
25. ADDITIONAL REQIREMENT COMMUNICATION PORT REQUIRED
IN CONTROL PANEL
26. SON.AND REF.PUMP ISOLATION VALVE PROVIDED
MAKE AUDCO/DANDEKAR
27. PERFORMANCE TESTING FULL LOAD PERFORMANCE TEST AT
VL-FACTORY